Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20248F35321 May 1998Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being AdoptedReverse polarity
ML20211M9483 October 1997Supplemental Part 21 Rept Re Condition Effected Emergency Svc Water Pumps Supplied by Bw/Ip Intl Inc to Gpu Nuclear, Oyster Creek Nuclear Generation Station.No Other Nuclear Generating Stations Effected by Notification
ML20211B74624 September 1997Part 21 Rept Re Failure of Emergency Service Water Pump Due to Threaded Flange Attaching Column to Top Series Case Failure.Caused by Dissimilar Metals.Pumps in High Ion Svc Will Be Upgraded to 316 Stainless Steel Matl
ML20140J19812 June 1997Part 21 Rept Re Failures of GE Type CR120AD Relays Dedicated for SR Use.Resulting High Current Through Short Circuit Caused Magnet Wire to Fuse & Produced Energetic Arc at Failure
ML20140A47627 May 1997Provides Addl Info to 970429 Part 21 Rept Re Potential safety-related Problem W/Asco HV 266000-007J Scram Solenoid Pilot Valves.Corrective Actions Also Listed
ML20140G55529 April 1997Part 21 Rept Re Potential safety-related Problems W/Asco HV 266000-007J Scram Solenoid Pilot Valves (Sspv).Caused by Hardening of Core Disc in SSPV Pilot Head.Investigation Is Continuing
ML20134F5744 November 1996Part 21 Rept Re non-compliance for DG Control Sys.Licensee Revised Component Dedication Rept to Require Removal of Jumper & Require Checking Auxiliary Contact Arm Screws for Tightness.Gpu Only User Affected by Notification
ML20078F60230 January 1995Part 21 Rept Re Possibilities of Some Nonconforming Diodes May Have Been Used in Safety Related Spare Parts Provided for S4N,D4N,T4N & 2100C
ML20056D70715 July 1993Part 21 Rept Re Reportable defect-75 PSIG Relief Check Valve 1 Npt,Emd 9521844,Kepner 416C-1-75
ML20102B20724 June 1992Part 21 Rept Re Cracking of Stellite 21 Hardfacing on Guide Nose of Poppets Supplied as Part of MSIV Leakage Improvement Mod.Initially Reported by Clei on 920522. Recommends That Liquid Penetrant Exam Be PerformedLiquid penetrant
ML20005G6835 January 1990Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced
ML20247D30112 July 1989Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified
ML20248G2514 April 1989Part 21 Rept Re Defect in Two Safety Relief Valves for Core Spray Sys Supplied by Lonergan.Relief Valves Ordered & Received for Installation & Two Valves Lifted Prematurely Removed from Sys & Sent to Offsite Test Facility
ML20207N46412 October 1988Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys
ML20205F32110 October 1988Part 21 Rept Re Potential Deviation from Tech Spec Concerning Ry Indicators Due to Operating Temp Effect on Analog Meter Movement.Initially Reported on 881006.Customers Verbally Notified on 881006-07
ML20210F47416 September 1986Part 21 Rept Re Possible Sticking in Closed or Partially Open Position on Dresser 3050 Diaphragm Valves.Initially Reported on 850118.Disc Caps,Including Chamfers on Outside Diameter,Will Be Modified
ML20203D02214 July 1986Part 21 Rept Re Air Monitoring Sys Probes Exhibiting Blue Tip Rather than Normal White Tip & Insensitive to Chlorine. Caused by Improper Handling/Storage.Advisory Bulletin Encl. Item Not Reportable Per Part 21
ML20141D8051 April 1986Part 21 Rept Re Model 402 Series Level Control Used for safety-related Application Shipped W/O Torque Check. Customers Will Be Notified by 860428 & Requested to Perform Torque Check.List of Plants Using Component EnclEarthquake
ML20210G99213 August 1985Part 21 Rept Re Failure of Isolated Worm Shaft Gear When Certain Critical Speeds Combined W/Repetitive Transfer of Actuator Clutch Mechanism from Manual (Handwheel) to Motor Drive Mode.Two Possible Solutions Noted
ML20126B7947 June 1985Part 21 Rept Re Procurement of Replacement Parts from Dresser Industries for Electromatic Relief Valves.Caused by Failure of Supplier to Notify Util That Dash 3 Parts Being Supplied for Dash 2 Model.Parts Replaced
ML20086U42524 February 1984Followup Part 21 Rept Re Defective Mechanical Snubber Capstan Springs Supplied by Pacific Scientific.Affected Utils Listed.Purchasers Have Been Notified & Advised to Work Directly W/Pacific Scientific in Disposition