MNuolear

"::= car" "

Route 9 South Forked River, New Jersey 08731-0388 609 971-4000 Writer's Direct Dial Number:

June 7, 1985 Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. DeYoung:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 In accordance with 10CFR21, GPUN is providing notification of a deviation from the technical requirements included in a procurement document.

GPUN procured replacement parts from Dresser Industries for the Electromatic Relief Valves (EMRVs), model 1525VX-2-SMY-1.

Replacement parts supplied by Dresser Industries were for an upgralled valve design, model 1525VX-3-XFB-ll.

Certain combinations of the dash 3 (-3) parts cannot be used with tWe dash 2

(-2) parts. The cause of concern was the failure of Dresser Industries to notify GPUN that dash 3 parts were being supplied and that care must be exercised in interchanging these parts.

Oyster Creek plant engineering considers that certain configurations, in wnich a pilot disc (of dash 3 design) is installed with a pilot disc stem (of dash 2 design), could leave excessive clearance such that the solenoid does not lift the pilot disc stem sufficiently to actuate the EMRY. A parts evaluation was performed on the Oyster Creek EMRVs to ensure that the correct configuration had been installed. No configuration problems were found in the installed replacement parts at Oyster Creek.

If you have any further questions or comments, please contact Mr. Drew Holland of nty staff at (609)971-4643.

Very truly yours, 8506140215 850607 PDR ADOCK 05000219

  1. d S

PDR Pt riedler Vice President and Director Oyster Creek PBF/KB/ dam (#0891 A) cc: Dr. Thomas E. Murley, Administrator NRC Resident Inspector Region I Oyster Creek Nuclear Gen. Station U.S. Nuclear Regulatory Comission Forked River, NJ 08731 631 Park Avenue King of Prussia, PA 19406 9

0 GPU Nuclear Corporation is a subsidiary of the General Pubhc Utihties Corporation