Text
Response to NuScale Topical Report Audit Question Question Number: A-NonLOCA.LTR-7 Receipt Date: 08/21/2023 Question:
In the non-LOCA TR EM and RSI-17 response, ER-126485 was provided in the eRR as a reference. DHRS scaling analysis was described at a high level. In order to understand the assumptions of derivations, make available for staff audit the calculation notes containing the detailed derivations of the DHRS PI groups and calculations of the final PI group numbers presented in the LTR and the analysis report.
Response
ER-126485 Rev. 0, previously provided in the electronic reading room (eRR), documents scaling analysis performed for the decay heat removal system (DHRS) testing at the NIST-2 facility. Additional information regarding the DHRS testing at the NIST-2 facility, including scaling analysis, is found in ((2(a),(c),ECI No changes to the SDAA are necessary. NuScale Nonproprietary NuScale Nonproprietary}}