March 23, 2023 E-62023 Orano TN 7160 Riverwood Drive Suite 200 U. S. Nuclear Regulatory Commission Columbia, MD 21046 Attn: Document Control Desk USA One White Flint North Tel: 410-910-6900 Fax: 434-260-8480 11555 Rockville Pike Rockville, MD 20852
Subject:
ANUH-01.0150, Standardized Advanced NUHOMS Updated Final Safety Analysis Report (UFSAR), Revision 12, and 10 CFR 72.48 Summary Report for the Period 11/18/21 to 3/23/23, Docket 72-1029
Reference:
Letter from Prakash Narayanan to NRC Document Control Desk, ANUH-01.0150, Standardized Advanced NUHOMS Updated Final Safety Analysis Report (UFSAR), Revision 11, and 10 CFR 72.48 Summary Report for the Period 3/13/21 to 11/17/21, Docket 72-1029, November 17, 2021 (E-58497)
Pursuant to 10 CFR 72.248, TN Americas LLC (TN) has updated ANUH-01.0150, the Standardized Advanced NUHOMS UFSAR, last updated by the referenced submittal, and herewith submits UFSAR Revision 12 replacement pages for docketing. This update incorporates changes implemented by TN for the time period of 11/18/21 to 3/23/23. No amendments to CoC 1029 became effective during this timeframe.
The changed areas are marked as follows:
x New or changed pages show Rev. 12 and 3/23 in the header.
x Changed areas are indicated using single revision bars in the margin.
x Newly inserted text is shown by italics.
I certify that this submittal accurately presents changes made since the referenced submittal.
This submittal includes proprietary information, which may not be used for any purpose other than NRC staff use of the UFSAR. In accordance with 10 CFR 2.390, Enclosure 1 provides an affidavit specifically requesting that this proprietary information be withheld from public disclosure. This submittal also includes security-related information, which should be withheld under 10 CFR 2.390. The Enclosures transmitted herein contain SUNSI. When separated from enclosures, this transmittal document is decontrolled.
E-62023 Document Control Desk Page 2 of 2 Proprietary version of the UFSAR replacement pages is provided as Enclosure 2. The public version of the UFSAR replacement pages is provided as Enclosure 3.
In addition, TN Americas LLC hereby submits a 10 CFR 72.48 summary report pursuant to the requirements of 10 CFR 72.48(d)(2). The last 10 CFR 72.48 summary report was provided in the referenced submittal. Enclosure 4 provides a brief description of changes, tests, and experiments, including a summary of the 10 CFR 72.48 evaluation of each change implemented from 11/18/21 to 3/23/23 for the Standardized Advanced NUHOMS System, including indication as to whether the evaluations had associated UFSAR changes that were incorporated into the UFSAR.
Should you have any questions regarding this submittal, please do not hesitate to contact Mr.
Douglas Yates at 434-832-3101, or by email at Douglas.Yates@orano.group.
Prakash Narayanan Chief Technical Officer cc: Christian Jacobs (NRC DFM)
Enclosures:
- 1. Affidavit Pursuant to 10 CFR 2.390
- 2. Replacement Pages for ANUH-01.0150, Standardized Advanced NUHOMS UFSAR, Revision 12 (Proprietary Version)
- 3. Replacement Pages for ANUH-01.0150, Standardized Advanced NUHOMS UFSAR, Revision 12 (Public Version)
- 4. Report of 10 CFR 72.48 Evaluations Performed for the Standardized Advanced NUHOMS System for the Period 11/18/21 to 3/23/23
Enclosure 1 to E-62023 AFFIDAVIT PURSUANT TO 10 CFR 2.390 TN Americas LLC )
County of Howard )
I, Prakash Narayanan, depose and say that I am a Vice President of TN Americas LLC, duly authorized to execute this affidavit, and have reviewed or caused to have reviewed the information which is identified as proprietary and referenced in the paragraph immediately below. I am submitting this affidavit in conformance with the provisions of 10 CFR 2.390 of the Commissions regulations for withholding this information.
The information for which proprietary treatment is sought is contained in Enclosure 2 and is listed below:
- Enclosure 2, Portions of the CoC 1029 updated final safety analysis report (UFSAR) chapters This document has been appropriately designated as proprietary.
I have personal knowledge of the criteria and procedures utilized by TN Americas LLC in designating information as a trade secret, privileged or as confidential commercial or financial information.
Pursuant to the provisions of paragraph (b) (4) of Section 2.390 of the Commissions regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure, included in the above referenced document, should be withheld.
- 1) The information sought to be withheld from public disclosure involves portions of the updated final safety analysis report, related to the design of dry spent fuel storage systems, which are owned and have been held in confidence by TN Americas LLC.
- 2) The information is of a type customarily held in confidence by TN Americas LLC, and not customarily disclosed to the public. TN Americas LLC has a rational basis for determining the types of information customarily held in confidence by it.
- 3) Public disclosure of the information is likely to cause substantial harm to the competitive position of TN Americas LLC, because the information consists of descriptions of the design of dry spent fuel storage systems, the application of which provide a competitive economic advantage. The availability of such information to competitors would enable them to modify their product to better compete with TN Americas LLC, take marketing or other actions to improve their products position or impair the position of TN Americas LLCs product, and avoid developing similar data and analyses in support of their processes, methods or apparatus.
Further the deponent sayeth not.
Prakash Narayanan Chief Technical Officer Subscribed and sworn before me thisj b day of March, 2023.
MARYANNS D ATFNZA Notary Put. .
Anne Arundel County My Commission Expires Maryland My Commission Expires March 02, 2025 Page 1 of 1
Enclosure 2 to E-62023 Replacement Pages for ANUH-01.0150, Standardized Advanced NUHOMS UFSAR, Revision 12 Withheld Pursuant to 10 CFR 2.390
Enclosure 3 to E-62023 Replacement Pages for ANUH-01.0150, Standardized Advanced NUHOMS UFSAR, Revision 12 (Public Version)
ANUH-01.0150 Revision 12 NON-PROPRIETARY UPDATED FINAL SAFETY ANALYSIS REPORT FOR THE STANDARDIZED ADVANCED NUHOMS HORIZONTAL MODULAR STORAGE SYSTEM FOR IRRADIATED NUCLEAR FUEL By TN Americas LLC(1)
Columbia, MD March 2023 (1)
TN Americas LLC, formerly AREVA TN, and Transnuclear, Inc. (herein referred to as TN Americas LLC, AREVA TN, Transnuclear, Inc., Transnuclear, or TN)
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 REVISION LOG SHEET UFSAR Date Record of Changes/FCNs Changed Pages Revision 0 3/19/03 None All FCNs 721029-39, 40, 62, 65, 81, 89, 1 3/21/05 See List of Effective Pages 92, 124, 126, 165, 169 & 175 FCNs 721029-182, 185, 103 R-1, 162 2 8/17/06 R-1, 166, 173 R-1, 176 R-1,177 and See List of Effective Pages 204 FCNs 721029-202, 205, 206, 208, 215, 3 8/15/08 See List of Effective Pages 220, 222 R1, 232, 239, 246, 257, 272 FCNs 721029-275, 280 R-1, 285, 294, 4 8/12/10 See List of Effective Pages 303, 311, 312 R-1, 316 FCNs 721029-339, 348 R-1, 351 R-1, 5 8/13/12 See List of Effective Pages 352, 353, 354, 356, 364 6 8/13/14 FCN 721029-385 See List of Effective Pages FCN 721029-374 R-1, 378 R-1, 7 8/11/16 386 R-1, 394, 407 R-1, 414, 415, See List of Effective Pages 416 R-1, 417 FCN 721029-418, 419 R-1, 420 R-1, 8 8/13/18 See List of Effective Pages 421, 422 9 3/12/19 FCN 721029-424 See List of Effective Pages 10 3/12/21 FCN 721029-423, 425, 426, 429 R-1 See List of Effective Pages 11 11/17/21 FCN 721029-432 R-0, 435 R-1 See List of Effective Pages 12 3/23/23 FCNs 721029-438, 440 R-1, 441, 443 See List of Effective Pages ANUH-01.0150 ii
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date Title Page 12 March 2023 LOEP-22 12 03/23 i 8 08/18 LOEP-23 12 03/23 ii 11 11/21 LOEP-24 12 03/23 iii 7 08/16 iv 8 08/18 1-1 7 08/16 v 11 11/21 1-1a 11 11/21 vi 11 11/21 1.1-1 5 08/12 vii 11 11/21 1.1-2 5 08/12 viii 11 11/21 1.1-3 0 02/03 ix 11 11/21 1.1-4 0 02/03 x 11 11/21 1.2-1 5 08/12 xi 11 11/21 1.2-2 5 08/12 xii 11 11/21 1.2-3 7 08/16 xiii 11 11/21 1.2-4 5 08/12 xiv 11 11/21 1.2-5 0 02/03 xv 11 11/21 1.2-6 0 02/03 xvi 11 11/21 1.2-7 2 08/06 xvii 11 11/21 1.2-8 11 11/21 xviii 11 11/21 1.2-9 5 08/12 xix 11 11/21 1.2-9a 10 03/21 xx 11 11/21 1.2-10 0 02/03 xxi 11 11/21 1.2-11 0 02/03 xxii 11 11/21 1.2-12 0 02/03 xxiii 11 11/21 1.2-13 2 08/06 xxiv 11 11/21 1.3-1 7 08/16 xxv 11 11/21 1.4-1 5 08/12 xxvi 11 11/21 1.4-2 0 02/03 xxvii 11 11/21 1.4-3 0 02/03 1.4-4 0 02/03 LOEP-1 12 03/23 1.5-1 12 03/23 LOEP-2 12 03/23 DWG: (sh. 1 of 6) 6 7/18/18 LOEP-3 12 03/23 NUH-05-4010 LOEP-4 12 03/23 DWG: (sh. 2 of 6) 6 Not shown LOEP-5 12 03/23 NUH-05-4010 LOEP-6 12 03/23 DWG: (sh. 3 of 6) 6 Not shown LOEP-7 12 03/23 NUH-05-4010 LOEP-8 12 03/23 DWG: (sh. 4 of 6) 6 Not shown LOEP-9 12 03/23 NUH-05-4010 LOEP-10 12 03/23 DWG: (sh. 5 of 6) 6 Not shown LOEP-11 12 03/23 NUH-05-4010 LOEP-12 12 03/23 DWG: (sh. 6 of 6) 6 Not shown LOEP-13 12 03/23 NUH-05-4010 LOEP-14 12 03/23 DWG: (sh. 1 of 11) 10 3/8/23 LOEP-15 12 03/23 NUH-03-4011 LOEP-16 12 03/23 DWG: (sh. 2 of 11) 10 Not shown LOEP-17 12 03/23 NUH-03-4011 LOEP-18 12 03/23 DWG: (sh. 3 of 11) 10 Not shown LOEP-19 12 03/23 NUH-03-4011 LOEP-20 12 03/23 DWG: (sh. 4 of 11) 10 Not shown LOEP-21 12 03/23 NUH-03-4011 ANUH-01.0150 LOEP-1
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date DWG: (sh. 5 of 11) 10 Not shown 3.1-7 5 08/12 NUH-03-4011 3.1-8 5 08/12 DWG: (sh. 6 of 11) 10 Not shown 3.1-9 5 08/12 NUH-03-4011 3.1-10 5 08/12 DWG: (sh. 7 of 11) 10 Not shown 3.1-11 0 02/03 NUH-03-4011 3.1-12 1 03/05 DWG: (sh. 8 of 11) 10 Not shown 3.1-13 0 02/03 NUH-03-4011 3.1-14 10 03/21 DWG: (sh. 9 of 11) 10 Not shown 3.1-15 0 02/03 NUH-03-4011 3.1-16 0 02/03 DWG: (sh. 10 of 11) 10 Not shown 3.1-17 0 02/03 NUH-03-4011 3.1-18 0 02/03 DWG: (sh.11 of 11) 10 Not shown 3.1-19 0 02/03 NUH-03-4011 3.1-20 0 02/03 3.1-21 0 02/03 2.1-1 7 08/16 3.1-22 5 08/12 2.1-1a 7 08/16 3.1-23 0 02/03 2.1-2 5 08/12 3.1-24 0 02/03 2.1-3 0 02/03 3.1-25 0 02/03 2.1-4 5 08/12 3.1-26 0 02/03 2.1-5 5 08/12 3.1-27 0 02/03 2.1-6 0 02/03 3.1-28 5 08/12 3.1-29 5 08/12 2.2-1 5 08/12 3.1-30 0 02/03 2.2-2 0 02/03 3.1-31 2 08/06 2.2-3 5 08/12 3.1-32 0 02/03 2.2-4 0 02/03 3.1-33 0 02/03 2.2-5 0 02/03 3.1-34 0 02/03 2.2-6 0 02/03 3.1-35 0 02/03 2.2-7 0 02/03 3.1-36 0 02/03 2.2-8 0 02/03 3.2-1 0 02/03 2.2-9 0 02/03 3.2-2 5 08/12 2.3-1 0 02/03 3.2-3 0 02/03 2.3-2 2 08/06 3.2-4 0 02/03 2.3-3 5 08/12 3.3-1 11 11/21 2.3-4 5 08/12 3.3-2 11 11/21 2.3-5 0 02/03 3.3-3 0 02/03 2.3-6 1 03/05 3.3-4 0 02/03 2.4-1 5 08/12 3.3-5 0 02/03 2.5-1 5 08/12 3.3-6 0 02/03 2.5-2 5 08/12 3.3-7 0 02/03 2.5-3 8 08/18 3.3-8 0 02/03 2.6-1 2 08/06 3.3-9 0 02/03 2.6-2 2 08/06 3.4-1 0 02/03 3.4-2 0 02/03 3.1-1 7 08/16 3.4-3 2 08/06 3.1-2 0 02/03 3.4-4 0 02/03 3.1-3 3 08/08 3.4-5 0 02/03 3.1-4 0 02/03 3.4-6 0 02/03 3.1-5 5 08/12 3.5-1 11 11/21 3.1-6 2 08/06 ANUH-01.0150 LOEP-2
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 3.5-2 11 11/21 3.6-40 0 02/03 3.5-2a 11 11/21 3.6-41 0 02/03 3.5-3 0 02/03 3.6-42 5 08/12 3.5-4 0 02/03 3.6-43 0 02/03 3.5-5 9 03/19 3.6-44 0 02/03 3.5-6 0 02/03 3.6-45 0 02/03 3.5-7 0 02/03 3.6-46 0 02/03 3.5-8 5 08/12 3.6-47 0 02/03 3.5-9 0 02/03 3.6-48 0 02/03 3.5-10 0 02/03 3.6-49 0 02/03 3.5-11 0 02/03 3.6-50 0 02/03 3.6-1 5 08/12 3.6-51 0 02/03 3.6-2 0 02/03 3.6-52 0 02/03 3.6-3 0 02/03 3.6-53 0 02/03 3.6-4 0 02/03 3.6-54 0 02/03 3.6-5 5 08/12 3.6-55 0 02/03 3.6-6 0 02/03 3.6-56 0 02/03 3.6-7 5 08/12 3.6-57 0 02/03 3.6-8 0 02/03 3.6-58 2 08/06 3.6-9 5 08/12 3.6-59 11 11/21 3.6-10 5 08/12 3.6-60 11 11/21 3.6-11 11 11/21 3.6-12 0 02/03 4-1 7 08/16 3.6-13 0 02/03 4.1-1 5 08/12 3.6-14 0 02/03 4.1-2 0 02/03 3.6-15 0 02/03 4.1-3 0 02/03 3.6-16 0 02/03 4.1-4 0 02/03 3.6-17 0 02/03 4.1-5 0 02/03 3.6-18 0 02/03 4.1-6 0 02/03 3.6-19 0 02/03 4.1-7 0 02/03 3.6-20 2 08/06 4.1-8 0 02/03 3.6-21 0 02/03 4.2-1 0 02/03 3.6-22 0 02/03 4.2-2 0 02/03 3.6-23 0 02/03 4.2-3 0 02/03 3.6-24 0 02/03 4.2-4 0 02/03 3.6-25 0 02/03 4.2-5 0 02/03 3.6-26 0 02/03 4.2-6 5 08/12 3.6-27 5 08/12 4.2-7 0 02/03 3.6-28 0 02/03 4.3-1 0 02/03 3.6-29 0 02/03 4.4-1 11 11/21 3.6-30 5 08/12 4.4-2 0 02/03 3.6-31 0 02/03 4.4-3 5 08/12 3.6-32 0 02/03 4.4-4 0 02/03 3.6-33 0 02/03 4.4-5 0 02/03 3.6-34 0 02/03 4.4-6 8 08/18 3.6-35 0 02/03 4.4-6a 1 03/05 3.6-36 0 02/03 4.4-7 8 08/18 3.6-37 0 02/03 4.4-8 0 02/03 3.6-38 1 03/05 4.4-9 8 08/18 3.6-39 0 02/03 4.4-10 8 08/18 ANUH-01.0150 LOEP-3
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 4.4-11 0 02/03 4.4-12 0 02/03 5-1 7 08/16 4.4-13 5 08/12 5.1-1 0 02/03 4.4-14 0 02/03 5.1-2 0 02/03 4.4-15 0 02/03 5.1-3 9 03/19 4.4-16 0 02/03 5.1-4 0 02/03 4.4-17 0 02/03 5.1-5 0 02/03 4.4-18 0 02/03 5.1-6 0 02/03 4.4-19 0 02/03 5.1-7 0 02/03 4.4-20 0 02/03 5.1-8 0 02/03 4.4-21 0 02/03 5.1-9 0 02/03 4.4-22 0 02/03 5.1-10 0 02/03 4.4-23 0 02/03 5.2-1 5 08/12 4.4-24 0 02/03 5.2-2 0 02/03 4.4-25 0 02/03 5.2-3 0 02/03 4.4-25a 9 03/19 5.2-4 5 08/12 4.4-26 0 02/03 5.2-5 0 02/03 4.4-27 0 02/03 5.2-6 5 08/12 4.4-28 0 02/03 5.2-7 5 08/12 4.4-29 0 02/03 5.2-8 5 08/12 4.4-30 0 02/03 5.2-9 0 02/03 4.4-31 0 02/03 5.2-10 5 08/12 4.4-32 0 02/03 5.2-11 5 08/12 4.4-33 0 02/03 5.2-12 0 02/03 4.5-1 8 08/18 5.2-13 0 02/03 4.5-2 0 02/03 5.2-14 0 02/03 4.6-1 0 02/03 5.2-15 0 02/03 4.6-2 8 08/18 5.2-16 0 02/03 4.6-3 8 08/18 5.2-17 5 08/12 4.6-4 0 02/03 5.2-18 5 08/12 4.6-5 0 02/03 5.2-19 5 08/12 4.6-6 0 02/03 5.2-20 5 08/12 4.7-1 9 03/19 5.2-21 0 02/03 4.7-2 9 03/19 5.2-22 5 08/12 4.7-3 8 08/18 5.2-23 0 02/03 4.7-4 0 02/03 5.2-24 0 02/03 4.7-5 0 02/03 5.3-1 0 02/03 4.7-6 0 02/03 5.3-2 10 03/21 4.7-7 0 02/03 5.3-3 0 02/03 4.7-8 0 02/03 5.3-4 0 02/03 4.8-1 5 08/12 5.3-5 5 08/12 4.8-2 2 08/06 5.3-6 0 02/03 4.8-3 0 02/03 5.3-7 5 08/12 4.8-4 0 02/03 5.3-8 0 02/03 4.8-5 0 02/03 5.4-1 0 02/03 4.8-6 0 02/03 5.4-2 0 02/03 4.8-7 5 08/12 5.4-3 0 02/03 4.8-8 0 02/03 5.4-4 0 02/03 4.8-9 5 08/12 5.4-5 0 02/03 4.8-10 0 02/03 5.4-6 0 02/03 ANUH-01.0150 LOEP-4
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 5.4-7 0 02/03 6.3-20 0 02/03 5.4-8 0 02/03 6.3-21 0 02/03 5.4-9 0 02/03 6.3-22 0 02/03 5.4-10 0 02/03 6.4-1 0 02/03 5.4-11 0 02/03 6.4-2 0 02/03 5.4-12 0 02/03 6.4-3 0 02/03 5.4-13 0 02/03 6.4-4 0 02/03 5.4-14 0 02/03 6.4-5 0 02/03 5.4-15 0 02/03 6.4-6 0 02/03 5.4-16 0 02/03 6.4-7 0 02/03 5.4-17 0 02/03 6.4-8 0 02/03 5.4-18 0 02/03 6.4-9 0 02/03 5.4-19 0 02/03 6.4-10 0 02/03 5.4-20 0 02/03 6.4-11 0 02/03 5.4-21 0 02/03 6.4-12 0 02/03 5.4-22 0 02/03 6.4-13 0 02/03 5.4-23 0 02/03 6.4-14 5 08/12 5.4-24 0 02/03 6.4-15 0 02/03 5.5-1 2 08/06 6.4-16 0 02/03 5.5-2 0 02/03 6.4-17 0 02/03 5.5-3 0 02/03 6.4-18 0 02/03 5.5-4 0 02/03 6.5-1 0 02/03 6.5-2 0 02/03 6.1-1 7 08/16 6.5-3 0 02/03 6.1-1a 7 08/16 6.5-4 0 02/03 6.1-2 5 08/12 6.5-5 0 02/03 6.1-3 0 02/03 6.5-6 0 02/03 6.1-4 0 02/03 6.5-7 0 02/03 6.2-1 0 02/03 6.5-8 0 02/03 6.2-2 0 02/03 6.6-1 2 08/06 6.2-3 0 02/03 6.6-2 0 02/03 6.3-1 5 08/12 6.6-3 0 02/03 6.3-2 0 02/03 6.6-4 0 02/03 6.3-3 0 02/03 6.6-5 0 02/03 6.3-4 0 02/03 6.6-6 0 02/03 6.3-5 0 02/03 6.6-7 0 02/03 6.3-6 0 02/03 6.6-8 0 02/03 6.3-7 11 11/21 6.6-9 0 02/03 6.3-8 0 02/03 6.6-10 0 02/03 6.3-9 0 02/03 6.6-11 0 02/03 6.3-10 0 02/03 6.6-12 0 02/03 6.3-11 0 02/03 6.6-13 0 02/03 6.3-12 0 02/03 6.6-14 0 02/03 6.3-13 0 02/03 6.6-15 0 02/03 6.3-14 0 02/03 6.6-16 0 02/03 6.3-15 0 02/03 6.6-17 0 02/03 6.3-16 0 02/03 6.6-18 0 02/03 6.3-17 0 02/03 6.6-19 0 02/03 6.3-18 0 02/03 6.6-20 0 02/03 6.3-19 0 02/03 6.6-21 0 02/03 ANUH-01.0150 LOEP-5
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 6.6-22 0 02/03 6.6-72 0 02/03 6.6-23 0 02/03 6.6-73 0 02/03 6.6-24 0 02/03 6.6-74 0 02/03 6.6-25 0 02/03 6.6-75 0 02/03 6.6-26 0 02/03 6.6-76 0 02/03 6.6-27 0 02/03 6.6-77 0 02/03 6.6-28 0 02/03 6.6-78 0 02/03 6.6-29 0 02/03 6.6-79 0 02/03 6.6-30 0 02/03 6.6-80 0 02/03 6.6-31 0 02/03 6.6-81 0 02/03 6.6-32 0 02/03 6.6-82 0 02/03 6.6-33 0 02/03 6.6-83 0 02/03 6.6-34 0 02/03 6.6-84 0 02/03 6.6-35 0 02/03 6.6-85 0 02/03 6.6-36 0 02/03 6.6-86 0 02/03 6.6-37 0 02/03 6.6-87 0 02/03 6.6-38 0 02/03 6.6-88 0 02/03 6.6-39 0 02/03 6.6-89 0 02/03 6.6-40 0 02/03 6.6-90 0 02/03 6.6-41 0 02/03 6.6-91 0 02/03 6.6-42 0 02/03 6.6-92 0 02/03 6.6-43 0 02/03 6.6-93 0 02/03 6.6-44 0 02/03 6.6-45 0 02/03 7.1-1 7 08/16 6.6-46 0 02/03 7.1-1a 7 08/16 6.6-47 0 02/03 7.1-2 5 08/12 6.6-48 0 02/03 7.1-2a 5 08/12 6.6-49 0 02/03 7.1-3 0 02/03 6.6-50 0 02/03 7.2-1 11 11/21 6.6-51 0 02/03 7.3-1 2 08/06 6.6-52 0 02/03 7.4-1 2 08/06 6.6-53 0 02/03 6.6-54 0 02/03 8-1 7 08/16 6.6-55 0 02/03 8.1-1 1 03/05 6.6-56 0 02/03 8.1-2 5 08/12 6.6-57 0 02/03 8.1-3 5 08/12 6.6-58 0 02/03 8.1-4 0 02/03 6.6-59 0 02/03 8.1-5 1 03/05 6.6-60 0 02/03 8.1-6 5 08/12 6.6-61 0 02/03 8.1-7 5 08/12 6.6-62 0 02/03 8.1-8 3 08/08 6.6-63 0 02/03 8.1-9 3 08/08 6.6-64 0 02/03 8.1-10 1 03/05 6.6-65 0 02/03 8.1-11 0 02/03 6.6-66 0 02/03 8.1-12 0 02/03 6.6-67 0 02/03 8.1-13 2 08/06 6.6-68 0 02/03 8.1-14 2 08/06 6.6-69 0 02/03 8.1-15 0 02/03 6.6-70 0 02/03 8.1-16 0 02/03 6.6-71 0 02/03 8.2-1 5 08/12 ANUH-01.0150 LOEP-6
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 8.2-2 9 03/19 11-1 7 08/16 8.2-3 9 03/19 11.1-1 0 02/03 8.2-4 0 02/03 11.1-2 0 02/03 8.2-5 0 02/03 11.1-3 0 02/03 8.2-6 0 02/03 11.2-1 5 08/12 8.2-7 0 02/03 11.2-2 0 02/03 8.2-8 0 02/03 11.2-3 0 02/03 8.2-9 0 02/03 11.2-4 0 02/03 8.3-1 0 02/03 11.2-5 0 02/03 11.2-6 0 02/03 9.1-1 7 08/16 11.2-7 0 02/03 9.1-1a 7 08/16 11.2-8 0 02/03 9.1-2 2 08/06 11.2-9 0 02/03 9.1-3 0 02/03 11.2-10 0 02/03 9.1-4 0 02/03 11.2-11 5 08/12 9.2-1 5 08/12 11.2-12 0 02/03 9.2-2 0 02/03 11.2-13 0 02/03 9.2-3 0 02/03 11.2-14 0 02/03 9.2-4 0 02/03 11.2-15 0 02/03 9.3-1 5 08/12 11.2-16 0 02/03 9.3-2 0 02/03 11.2-17 0 02/03 9.4-1 5 08/12 11.2-18 0 02/03 11.2-19 0 02/03 10.1-1 7 08/16 11.2-20 0 02/03 10.1-1a 7 08/16 11.2-21 11 11/21 10.1-2 5 08/12 11.2-22 0 02/03 10.1-3 5 08/12 11.2-23 0 02/03 10.2-1 2 08/06 11.2-24 5 08/12 10.2-2 5 08/12 11.2-25 5 08/12 10.2-3 0 02/03 11.2-26 5 08/12 10.2-4 5 08/12 11.2-27 9 03/19 10.2-5 5 08/12 11.2-28 0 02/03 10.2-6 0 02/03 11.2-29 0 02/03 10.2-7 0 02/03 11.2-30 5 08/12 10.2-8 0 02/03 11.2-31 0 02/03 10.2-9 0 02/03 11.2-32 0 02/03 10.2-10 0 02/03 11.2-33 0 02/03 10.2-11 0 02/03 11.2-34 0 02/03 10.2-12 0 02/03 11.2-35 0 02/03 10.2-13 0 02/03 11.2-36 0 02/03 10.2-14 5 08/12 11.2-37 0 02/03 10.2-15 0 02/03 11.2-38 0 02/03 10.2-16 0 02/03 11.2-39 0 02/03 10.3-1 5 08/12 11.2-40 0 02/03 10.3-2 5 08/12 11.2-41 0 02/03 10.3-3 5 08/12 11.2-42 0 02/03 10.3-4 2 08/06 11.2-43 0 02/03 10.3-5 2 08/06 11.2-44 0 02/03 10.4-1 0 02/03 11.2-45 0 02/03 11.2-46 0 02/03 ANUH-01.0150 LOEP-7
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date 11.2-47 0 02/03 15-9 11 11/21 11.2-48 0 02/03 15-10 11 11/21 11.2-49 0 02/03 15-11 11 11/21 11.2-50 0 02/03 15-12 11 11/21 11.2-51 0 02/03 15-13 11 11/21 11.3-1 0 02/03 15-14 11 11/21 11.3-2 2 08/06 15-15 11 11/21 15-16 11 11/21 12-1 7 08/16 15-17 11 11/21 12-2 5 08/12 15-18 11 11/21 12-3 5 08/12 15-19 11 11/21 12-4 5 08/12 15-20 11 11/21 12-5 9 03/19 15-21 11 11/21 12-6 5 08/12 15-22 11 11/21 12-7 5 08/12 15-23 11 11/21 12-8 5 08/12 15-24 11 11/21 12-9 5 08/12 15-25 11 11/21 12-10 5 08/12 15-26 11 11/21 12-11 5 08/12 15-27 11 11/21 12-12 5 08/12 15-28 11 11/21 12-13 5 08/12 15-29 11 11/21 12-14 5 08/12 15-30 11 11/21 12-15 5 08/12 15-31 11 11/21 15-32 11 11/21 13-1 7 08/16 15-33 11 11/21 13.1-1 5 08/12 15-34 11 11/21 13.1-2 5 08/12 15-35 11 11/21 13.1-3 1 03/05 15-36 11 11/21 13.2-1 5 08/12 15-37 11 11/21 13.2-2 5 08/12 15-38 11 11/21 13.3-1 5 08/12 15-39 11 11/21 13.3-2 5 08/12 15-40 11 11/21 13.3-3 0 02/03 15-41 11 11/21 13.3-4 0 02/03 13.4-1 5 08/12 i 9 03/19 13.5-1 1 03/05 ii 9 03/19 iii 9 03/19 14.1-1 9 03/19 iv 9 03/19 14.1-2 9 03/19 v 9 03/19 14.1-3 0 02/03 vi 9 03/19 14.2-1 10 03/21 vii 9 03/19 viii 9 03/19 15-1 11 11/21 ix 9 03/19 15-2 11 11/21 x 9 03/19 15-3 11 11/21 xi 9 03/19 15-4 11 11/21 xii 9 03/19 15-5 11 11/21 xiii 9 03/19 15-6 11 11/21 xiv 9 03/19 15-7 11 11/21 xv 9 03/19 15-8 11 11/21 ANUH-01.0150 LOEP-8
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.1.1-1 5 08/12 A.2.3-2 5 08/12 A.1.1-2 5 08/12 A.2.3-3 5 08/12 A.1.1-3 2 08/06 A.2.3-4 5 08/12 A.1.2-1 5 08/12 A.2.3-5 5 08/12 A.1.2-2 11 11/21 A.2.4-1 5 08/12 A.1.2-3 11 11/21 A.2.5-1 5 08/12 A.1.2-4 2 08/06 A.2.5-2 5 08/12 A.1.2-5 2 08/06 A.2.5-3 8 08/18 A.1.3-1 5 08/12 A.2.6-1 2 08/06 A.1.4-1 5 08/12 A.1.5-1 8 08/18 A.3.1-1 5 08/12 DWG: (sh. 1 of 8) 7 7/18/18 A.3.1-2 3 08/08 ANUH-01-4001 A.3.1-3 5 08/12 DWG: (sh. 2 of 8) 7 Not shown A.3.1-4 5 08/12 ANUH-01-4001 A.3.1-5 5 08/12 DWG: (sh. 3 of 8) 7 Not shown A.3.1-6 2 08/06 ANUH-01-4001 A.3.1-7 2 08/06 DWG: (sh. 4 of 8) 7 Not shown A.3.1-8 2 08/06 ANUH-01-4001 A.3.1-9 2 08/06 DWG: (sh. 5 of 8) 7 Not shown A.3.1-10 2 08/06 ANUH-01-4001 A.3.1-11 5 08/12 DWG: (sh. 6 of 8) 7 Not shown A.3.1-12 5 08/12 ANUH-01-4001 A.3.1-13 2 08/06 DWG: (sh. 7 of 8) 7 Not shown A.3.1-14 2 08/06 ANUH-01-4001 A.3.1-15 2 08/06 DWG: (sh. 8 of 8) 7 Not shown A.3.1-16 2 08/06 ANUH-01-4001 A.3.2-1 2 08/06 A.3.2-2 5 08/12 A.2.1-1 5 08/12 A.3.2-3 2 08/06 A.2.1-2 5 08/12 A.3.2-4 2 08/06 A.2.1-3 5 08/12 A.3.3-1 5 08/12 A.2.1-4 5 08/12 A.3.3-2 5 08/12 A.2.1-5 5 08/12 A.3.3-3 2 08/06 A.2.1-6 5 08/12 A.3.3-4 2 08/06 A.2.1-7 5 08/12 A.3.3-5 2 08/06 A.2.1-8 2 08/06 A.3.4-1 5 08/12 A.2.1-9 2 08/06 A.3.4-2 2 08/06 A.2.1-10 2 08/06 A.3.4-3 2 08/06 A.2.1-11 2 08/06 A.3.4-4 11 11/21 A.2.1-12 2 08/06 A.3.5-1 5 08/12 A.2.1-13 2 08/06 A.3.5-2 9 03/19 A.2.1-14 2 08/06 A.3.5-3 2 08/06 A.2.1-15 2 08/06 A.3.5-4 5 08/12 A.2.1-16 2 08/06 A.3.5-5 2 08/06 A.2.1-17 2 08/06 A.3.5-6 5 08/12 A.2.1-18 2 08/06 A.3.5-7 2 08/06 A.2.1-19 2 08/06 A.3.6-1 2 08/06 A.2.2-1 5 08/12 A.3.6-2 2 08/06 A.2.2-2 5 08/12 A.3.6-3 5 08/12 A.2.2-3 5 08/12 A.3.6-4 2 08/06 A.2.3-1 2 08/06 ANUH-01.0150 LOEP-9
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.3.6-5 2 08/06 A.4.3-1 2 08/06 A.3.6-6 5 08/12 A.4.4-1 2 08/06 A.3.6-7 2 08/06 A.4.4-2 2 08/06 A.3.6-8 2 08/06 A.4.4-3 2 08/06 A.3.6-8a 2 08/06 A.4.4-4 2 08/06 A.3.6-9 2 08/06 A.4.4-5 9 03/19 A.3.6-10 2 08/06 A.4.4-6 2 08/06 A.3.6-11 2 08/06 A.4.4-7 2 08/06 A.3.6-12 2 08/06 A.4.4-8 2 08/06 A.3.6-13 2 08/06 A.4.4-9 2 08/06 A.3.6-14 2 08/06 A.4.4-10 2 08/06 A.3.6-15 2 08/06 A.4.4-11 2 08/06 A.3.6-16 5 08/12 A.4.4-12 2 08/06 A.3.6-17 5 08/12 A.4.4-13 2 08/06 A.3.6-17a 2 08/06 A.4.4-14 2 08/06 A.3.6-18 2 08/06 A.4.4-15 2 08/06 A.3.6-19 2 08/06 A.4.4-16 2 08/06 A.3.6-20 2 08/06 A.4.4-17 2 08/06 A.3.6-21 2 08/06 A.4.4-18 2 08/06 A.3.6-22 2 08/06 A.4.4-19 2 08/06 A.3.6-23 2 08/06 A.4.4-20 2 08/06 A.3.6-24 2 08/06 A.4.4-21 4 08/10 A.3.6-25 5 08/12 A.4.4-22 4 08/10 A.3.6-26 2 08/06 A.4.4-23 9 03/19 A.3.6-27 2 08/06 A.4.4-24 2 08/06 A.3.6-27a 2 08/06 A.4.4-25 2 08/06 A.3.6-27b 2 08/06 A.4.4-26 2 08/06 A.3.6-27c 2 08/06 A.4.4-27 2 08/06 A.3.6-27d 2 08/06 A.4.4-28 2 08/06 A.3.6-27e 2 08/06 A.4.4-29 2 08/06 A.3.6-28 2 08/06 A.4.4-30 2 08/06 A.3.6-29 2 08/06 A.4.4-31 2 08/06 A.3.6-30 2 08/06 A.4.4-32 2 08/06 A.3.6-31 2 08/06 A.4.4-33 2 08/06 A.3.6-32 2 08/06 A.4.4-34 2 08/06 A.3.6-33 2 08/06 A.4.4-35 2 08/06 A.3.6-34 2 08/06 A.4.4-36 2 08/06 A.3.7-1 5 08/12 A.4.4-37 2 08/06 A.3.7-2 2 08/06 A.4.4-38 2 08/06 A.4.4-39 2 08/06 A.4-1 5 08/12 A.4.4-40 2 08/06 A.4.1-1 2 08/06 A.4.4-41 2 08/06 A.4.1-2 2 08/06 A.4.4-42 2 08/06 A.4.1-3 2 08/06 A.4.4-43 2 08/06 A.4.1-4 2 08/06 A.4.4-44 2 08/06 A.4.1-5 2 08/06 A.4.4-45 2 08/06 A.4.2-1 2 08/06 A.4.4-46 2 08/06 A.4.2-2 2 08/06 A.4.4-47 2 08/06 A.4.2-3 2 08/06 A.4.4-48 2 08/06 A.4.2-4 2 08/06 A.4.4-49 2 08/06 ANUH-01.0150 LOEP-10
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.4.4-50 2 08/06 A.4.10-13 2 08/06 A.4.4-51 2 08/06 A.4.10-14 2 08/06 A.4.5-1 2 08/06 A.4.10-15 2 08/06 A.4.6-1 2 08/06 A.4.10-16 2 08/06 A.4.6-2 2 08/06 A.4.10-17 2 08/06 A.4.6-3 2 08/06 A.4.10-18 2 08/06 A.4.6-4 2 08/06 A.4.10-19 2 08/06 A.4.6-5 2 08/06 A.4.10-20 2 08/06 A.4.6-6 2 08/06 A.4.11-1 5 08/12 A.4.6-7 2 08/06 A.4.11-2 5 08/12 A.4.7-1 9 03/19 A.4.11-3 9 03/19 A.4.7-2 2 08/06 A.4.11-4 9 03/19 A.4.7-3 2 08/06 A.4.11-5 9 03/19 A.4.7-4 2 08/06 A.4.11-6 9 03/19 A.4.7-5 2 08/06 A.4.11-7 9 03/19 A.4.7-6 5 08/12 A.4.11-8 9 03/19 A.4.7-7 2 08/06 A.4.11-9 9 03/19 A.4.7-8 2 08/06 A.4.11-10 9 03/19 A.4.7-9 5 08/12 A.4.11-11 9 03/19 A.4.7-10 2 08/06 A.4.11-12 9 03/19 A.4.7-11 2 08/06 A.4.11-13 9 03/19 A.4.7-12 2 08/06 A.4.11-14 9 03/19 A.4.7-13 2 08/06 A.4.11-15 9 03/19 A.4.7-14 2 08/06 A.4.11-16 9 03/19 A.4.7-15 2 08/06 A.4.11-17 9 03/19 A.4.7-16 2 08/06 A.4.11-18 9 03/19 A.4.7-17 2 08/06 A.4.11-19 9 03/19 A.4.7-18 5 08/12 A.4.11-20 9 03/19 A.4.8-1 2 08/06 A.4.11-21 9 03/19 A.4.9-1 5 08/12 A.4.11-22 9 03/19 A.4.9-2 2 08/06 A.4.11-23 9 03/19 A.4.9-3 2 08/06 A.4.11-24 9 03/19 A.4.9-4 2 08/06 A.4.9-5 5 08/12 A.5.1-1 5 08/12 A.4.9-6 2 08/06 A.5.1-2 2 08/06 A.4.9-7 2 08/06 A.5.1-3 5 08/12 A.4.9-8 2 08/06 A.5.1-4 11 11/21 A.4.9-9 2 08/06 A.5.1-5 11 11/21 A.4.10-1 2 08/06 A.5.1-5a 11 11/21 A.4.10-2 2 08/06 A.5.1-6 2 08/06 A.4.10-3 2 08/06 A.5.1-7 2 08/06 A.4.10-4 2 08/06 A.5.1-8 2 08/06 A.4.10-5 2 08/06 A.5.1-9 2 08/06 A.4.10-6 2 08/06 A.5.1-10 2 08/06 A.4.10-7 2 08/06 A.5.1-11 2 08/06 A.4.10-8 2 08/06 A.5.2-1 5 08/12 A.4.10-9 2 08/06 A.5.2-2 2 08/06 A.4.10-10 2 08/06 A.5.2-3 5 08/12 A.4.10-11 2 08/06 A.5.2-3a 2 08/06 A.4.10-12 2 08/06 A.5.2-4 5 08/12 ANUH-01.0150 LOEP-11
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.5.2-5 2 08/06 A.5.5-16 2 08/06 A.5.2-6 2 08/06 A.5.5-17 2 08/06 A.5.2-7 5 08/12 A.5.5-18 2 08/06 A.5.2-8 2 08/06 A.5.5-19 2 08/06 A.5.2-9 5 08/12 A.5.5-20 2 08/06 A.5.2-10 2 08/06 A.5.5-21 2 08/06 A.5.2-11 5 08/12 A.5.5-22 2 08/06 A.5.2-12 5 08/12 A.5.5-23 2 08/06 A.5.2-13 2 08/06 A.5.5-24 2 08/06 A.5.2-14 2 08/06 A.5.5-25 2 08/06 A.5.2-15 2 08/06 A.5.5-26 2 08/06 A.5.2-16 2 08/06 A.5.5-27 2 08/06 A.5.2-17 5 08/12 A.5.5-28 2 08/06 A.5.2-18 5 08/12 A.5.5-29 2 08/06 A.5.3-1 11 11/21 A.5.5-30 2 08/06 A.5.3-2 10 03/21 A.5.5-31 2 08/06 A.5.3-3 2 08/06 A.5.5-32 2 08/06 A.5.3-4 5 08/12 A.5.5-33 2 08/06 A.5.3-5 5 08/12 A.5.5-34 2 08/06 A.5.3-6 5 08/12 A.5.5-35 2 08/06 A.5.3-7 5 08/12 A.5.5-36 2 08/06 A.5.3-8 2 08/06 A.5.5-37 2 08/06 A.5.4-1 2 08/06 A.5.5-38 2 08/06 A.5.4-2 2 08/06 A.5.5-39 2 08/06 A.5.4-3 2 08/06 A.5.5-40 2 08/06 A.5.4-4 2 08/06 A.5.5-41 2 08/06 A.5.4-5 2 08/06 A.5.5-42 2 08/06 A.5.4-6 2 08/06 A.5.5-43 2 08/06 A.5.4-7 2 08/06 A.5.5-44 2 08/06 A.5.4-8 2 08/06 A.5.5-45 2 08/06 A.5.4-9 2 08/06 A.5.5-46 2 08/06 A.5.4-10 2 08/06 A.5.5-47 2 08/06 A.5.4-11 2 08/06 A.5.5-48 2 08/06 A.5.4-12 2 08/06 A.5.5-49 2 08/06 A.5.4-13 2 08/06 A.5.5-50 2 08/06 A.5.5-1 2 08/06 A.5.5-51 2 08/06 A.5.5-2 11 11/21 A.5.5-52 2 08/06 A.5.5-3 2 08/06 A.5.5-53 2 08/06 A.5.5-4 2 08/06 A.5.5-54 2 08/06 A.5.5-5 2 08/06 A.5.5-55 2 08/06 A.5.5-6 2 08/06 A.5.5-56 2 08/06 A.5.5-7 2 08/06 A.5.5-57 2 08/06 A.5.5-8 2 08/06 A.5.5-58 2 08/06 A.5.5-9 2 08/06 A.5.5-59 2 08/06 A.5.5-10 2 08/06 A.5.5-60 2 08/06 A.5.5-11 2 08/06 A.5.5-61 2 08/06 A.5.5-12 2 08/06 A.5.5-62 2 08/06 A.5.5-13 2 08/06 A.5.5-63 2 08/06 A.5.5-14 2 08/06 A.5.5-64 2 08/06 A.5.5-15 2 08/06 A.5.5-65 2 08/06 ANUH-01.0150 LOEP-12
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.5.5-66 2 08/06 A.6.1-2 5 08/12 A.5.5-67 2 08/06 A.6.2-1 5 08/12 A.5.5-68 2 08/06 A.6.2-2 5 08/12 A.5.5-69 2 08/06 A.6.3-1 5 08/12 A.5.5-70 2 08/06 A.6.3-2 5 08/12 A.5.5-71 2 08/06 A.6.3-3 5 08/12 A.5.5-72 2 08/06 A.6.3-4 5 08/12 A.5.5-73 2 08/06 A.6.3-5 5 08/12 A.5.5-74 2 08/06 A.6.3-6 11 11/21 A.5.5-75 2 08/06 A.6.3-7 2 08/06 A.5.5-76 2 08/06 A.6.3-8 2 08/06 A.5.5-77 2 08/06 A.6.3-9 2 08/06 A.5.5-78 2 08/06 A.6.3-10 5 08/12 A.5.5-79 2 08/06 A.6.3-11 3 08/08 A.5.5-80 2 08/06 A.6.3-12 2 08/06 A.5.5-81 2 08/06 A.6.3-13 5 08/12 A.5.5-82 2 08/06 A.6.3-14 2 08/06 A.5.5-83 2 08/06 A.6.3-15 2 08/06 A.5.5-84 2 08/06 A.6.3-16 2 08/06 A.5.5-85 2 08/06 A.6.3-17 2 08/06 A.5.5-86 2 08/06 A.6.3-18 2 08/06 A.5.5-87 2 08/06 A.6.4-1 5 08/12 A.5.5-88 2 08/06 A.6.4-2 5 08/12 A.5.5-89 2 08/06 A.6.4-3 5 08/12 A.5.5-90 2 08/06 A.6.4-4 5 08/12 A.5.5-91 2 08/06 A.6.4-5 5 08/12 A.5.5-92 2 08/06 A.6.4-6 5 08/12 A.5.5-93 2 08/06 A.6.4-7 2 08/06 A.5.5-94 2 08/06 A.6.4-8 5 08/12 A.5.5-95 2 08/06 A.6.4-9 5 08/12 A.5.5-96 2 08/06 A.6.4-10 5 08/12 A.5.5-97 2 08/06 A.6.4-11 5 08/12 A.5.5-98 2 08/06 A.6.4-12 5 08/12 A.5.5-99 2 08/06 A.6.4-13 5 08/12 A.5.5-100 2 08/06 A.6.4-14 5 08/12 A.5.5-101 2 08/06 A.6.4-15 5 08/12 A.5.5-102 2 08/06 A.6.4-16 5 08/12 A.5.5-103 2 08/06 A.6.4-17 5 08/12 A.5.5-104 2 08/06 A.6.4-18 5 08/12 A.5.5-105 2 08/06 A.6.4-19 5 08/12 A.5.5-106 2 08/06 A.6.4-20 5 08/12 A.5.5-107 2 08/06 A.6.4-21 2 08/06 A.5.5-108 2 08/06 A.6.4-22 2 08/06 A.5.5-109 2 08/06 A.6.4-23 2 08/06 A.5.5-110 2 08/06 A.6.4-24 5 08/12 A.5.5-111 2 08/06 A.6.4-25 2 08/06 A.5.5-112 2 08/06 A.6.4-26 2 08/06 A.6.4-27 2 08/06 A.6-1 5 08/12 A.6.4-28 2 08/06 A.6.1-1 5 08/12 A.6.4-29 2 08/06 ANUH-01.0150 LOEP-13
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.6.4-30 2 08/06 A.6.6-32 2 08/06 A.6.4-31 2 08/06 A.6.6-33 2 08/06 A.6.4-32 2 08/06 A.6.6-34 2 08/06 A.6.4-33 2 08/06 A.6.6-35 2 08/06 A.6.4-34 2 08/06 A.6.6-36 2 08/06 A.6.4-35 2 08/06 A.6.6-37 2 08/06 A.6.4-36 2 08/06 A.6.6-38 2 08/06 A.6.4-37 2 08/06 A.6.6-39 2 08/06 A.6.4-38 2 08/06 A.6.6-40 2 08/06 A.6.4-39 2 08/06 A.6.6-41 2 08/06 A.6.4-40 2 08/06 A.6.6-42 2 08/06 A.6.5-1 5 08/12 A.6.6-43 2 08/06 A.6.5-2 2 08/06 A.6.6-44 2 08/06 A.6.5-3 2 08/06 A.6.6-45 2 08/06 A.6.5-4 2 08/06 A.6.6-46 2 08/06 A.6.5-5 2 08/06 A.6.6-47 2 08/06 A.6.5-6 2 08/06 A.6.6-48 2 08/06 A.6.5-7 5 08/12 A.6.6-49 2 08/06 A.6.5-8 5 08/12 A.6.6-50 2 08/06 A.6.6-1 2 08/06 A.6.6-51 2 08/06 A.6.6-2 2 08/06 A.6.6-52 2 08/06 A.6.6-3 2 08/06 A.6.6-53 2 08/06 A.6.6-4 2 08/06 A.6.6-54 2 08/06 A.6.6-5 2 08/06 A.6.6-55 2 08/06 A.6.6-6 2 08/06 A.6.6-56 2 08/06 A.6.6-7 2 08/06 A.6.6-57 2 08/06 A.6.6-8 2 08/06 A.6.6-58 2 08/06 A.6.6-9 2 08/06 A.6.6-59 2 08/06 A.6.6-10 2 08/06 A.6.6-60 2 08/06 A.6.6-11 2 08/06 A.6.6-61 2 08/06 A.6.6-12 2 08/06 A.6.6-62 2 08/06 A.6.6-13 2 08/06 A.6.6-63 2 08/06 A.6.6-14 2 08/06 A.6.6-64 2 08/06 A.6.6-15 2 08/06 A.6.6-65 2 08/06 A.6.6-16 2 08/06 A.6.6-66 2 08/06 A.6.6-17 2 08/06 A.6.6-67 2 08/06 A.6.6-18 2 08/06 A.6.6-68 2 08/06 A.6.6-19 2 08/06 A.6.6-69 2 08/06 A.6.6-20 2 08/06 A.6.6-70 2 08/06 A.6.6-21 2 08/06 A.6.6-71 2 08/06 A.6.6-22 2 08/06 A.6.6-72 2 08/06 A.6.6-23 2 08/06 A.6.6-73 2 08/06 A.6.6-24 2 08/06 A.6.6-74 2 08/06 A.6.6-25 2 08/06 A.6.6-75 2 08/06 A.6.6-26 2 08/06 A.6.6-76 2 08/06 A.6.6-27 2 08/06 A.6.6-77 2 08/06 A.6.6-28 2 08/06 A.6.6-78 2 08/06 A.6.6-29 2 08/06 A.6.6-79 2 08/06 A.6.6-30 2 08/06 A.6.6-31 2 08/06 A.7.1-1 5 08/12 ANUH-01.0150 LOEP-14
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date A.7.1-2 5 08/12 A.10.2-12 2 08/06 A.7.1-3 5 08/12 A.10.2-13 5 08/12 A.7.1-4 2 08/06 A.10.2-14 2 08/06 A.7.2-1 5 08/12 A.10.2-15 2 08/06 A.7.3-1 5 08/12 A.10.3-1 5 08/12 A.7.4-1 5 08/12 A.10.3-2 2 08/06 A.10.3-3 5 08/12 A.8.1-1 5 08/12 A.10.3-4 2 08/06 A.8.1-2 2 08/06 A.10.3-5 2 08/06 A.8.1-3 5 08/12 A.10.4-1 11 11/21 A.8.1-4 2 08/06 A.8.1-5 2 08/06 A.11-1 5 08/12 A.8.1-6 5 08/12 A.11.1-1 5 08/12 A.8.1-6a 5 08/12 A.11.1-2 5 08/12 A.8.1-7 3 08/08 A.11.2-1 5 08/12 A.8.1-8 5 08/12 A.11.2-2 5 08/12 A.8.1-9 2 08/06 A.11.2-3 5 08/12 A.8.1-10 3 08/08 A.11.2-4 5 08/12 A.8.1-11 2 08/06 A.11.2-5 5 08/12 A.8.2-1 9 03/19 A.11.3-1 2 08/06 A.8.2-2 9 03/19 A.8.2-3 9 03/19 A.12-1 5 08/12 A.8.2-4 2 08/06 A.12-2 5 08/12 A.8.2-5 2 08/06 A.12-3 5 08/12 A.8.2-6 2 08/06 A.12-4 9 03/19 A.8.2-7 2 08/06 A.12-5 5 08/12 A.8.2-8 2 08/06 A.12-6 5 08/12 A.8.3-1 5 08/12 A.12-7 5 08/12 A.12-8 5 08/12 A.9.1-1 5 08/12 A.12-9 5 08/12 A.9.1-2 5 08/12 A.12-10 5 08/12 A.9.1-3 5 08/12 A.12-11 5 08/12 A.9.1-4 5 08/12 A.12-12 5 08/12 A.9.2-1 5 08/12 A.12-13 5 08/12 A.9.2-1a 5 08/12 A.12-14 5 08/12 A.9.3-1 5 08/12 A.9.4-1 2 08/06 A.13-1 2 08/06 A.10.1-1 5 08/12 A.14.1-1 9 03/19 A.10.2-1 11 11/21 A.14.1-2 9 03/19 A.10.2-2 5 08/12 A.14.1-3 2 08/06 A.10.2-3 11 11/21 A.14.2-1 10 03/21 A.10.2-4 11 11/21 A.10.2-5 11 11/21 B-i 7 08/16 A.10.2-6 2 08/06 B-ii 7 08/16 A.10.2-7 11 11/21 B-iii 7 08/16 A.10.2-8 2 08/06 B-iv 7 08/16 A.10.2-9 2 08/06 B-v 7 08/16 A.10.2-10 11 11/21 B-vi 7 08/16 A.10.2-11 2 08/06 B-vii 7 08/16 ANUH-01.0150 LOEP-15
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B-viii 7 08/16 DWG: (sh. 1 of 4) 0 8/9/16 B-ix 7 08/16 ANUH-01-4004 B-x 7 08/16 DWG: (sh. 2 of 4) 0 8/9/16 B-xi 7 08/16 ANUH-01-4004 B-xii 7 08/16 DWG: (sh. 3 of 4) 0 8/9/16 B-xiii 7 08/16 ANUH-01-4004 B-xiv 7 08/16 DWG: (sh. 4 of 4) 0 8/9/16 B-xv 7 08/16 ANUH-01-4004 B-xvi 7 08/16 DWG: (sh. 1 of 4) 0 8/9/16 B-xvii 7 08/16 ANUH-01-4005 B-xviii 7 08/16 DWG: (sh. 2 of 4) 0 8/9/16 B-xix 7 08/16 ANUH-01-4005 DWG: (sh. 3 of 4) 0 8/9/16 B.1-1 7 08/16 ANUH-01-4005 B.1.1-1 7 08/16 DWG: (sh. 4 of 4) 0 8/9/16 B.1.1-2 7 08/16 ANUH-01-4005 B.1.1-3 7 08/16 DWG: (sh. 1 of 1) 0 8/9/16 B.1.2-1 7 08/16 ANUH-01-4006 B.1.2-2 7 08/16 DWG: (sh. 1 of 14) 0 8/9/16 NUH-03-4012 B.1.2-3 7 08/16 DWG: (sh. 2 of 14) 0 8/9/16 B.1.2-4 7 08/16 NUH-03-4012 B.1.2-5 11 11/21 DWG: (sh. 3 of 14) 0 8/9/16 B.1.2-6 7 08/16 NUH-03-4012 B.1.2-7 7 08/16 DWG: (sh. 4 of 14) 0 8/9/16 B.1.2-8 7 08/16 NUH-03-4012 B.1.2-9 7 08/16 DWG: (sh. 5 of 14) 0 8/9/16 B.1.3-1 7 08/16 NUH-03-4012 B.1.4-1 7 08/16 DWG: (sh. 6 of 14) 0 8/9/16 B.1.4-2 7 08/16 NUH-03-4012 B.1.4-3 7 08/16 DWG: (sh. 7 of 14) 0 8/9/16 B.1.5-1 7 08/16 NUH-03-4012 B.1.5-2 7 08/16 DWG: (sh. 8 of 14) 0 8/9/16 DWG: (sh. 1 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 9 of 14) 0 8/9/16 DWG: (sh. 2 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 10 of 14) 0 8/9/16 DWG: (sh. 3 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 11 of 14) 0 8/9/16 DWG: (sh. 4 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 12 of 14) 0 8/9/16 DWG: (sh. 5 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 13 of 14) 0 8/9/16 DWG: (sh. 6 of 6) 0 8/9/16 NUH-03-4012 ANUH-01-4002 DWG: (sh. 14 of 14) 0 8/9/16 DWG: (sh. 1 of 3) 0 8/9/16 NUH-03-4012 ANUH-01-4003 DWG: (sh. 1 of 6) 0 8/9/16 DWG: (sh. 2 of 3) 0 8/9/16 NUH-03-4013 ANUH-01-4003 DWG: (sh. 2 of 6) 0 8/9/16 DWG: (sh. 3 of 3) 0 8/9/16 NUH-03-4013 ANUH-01-4003 ANUH-01.0150 LOEP-16
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date DWG: (sh. 3 of 6) 0 8/9/16 B.3.1-13 7 08/16 NUH-03-4013 B.3.1-14 7 08/16 DWG: (sh. 4 of 6) 0 8/9/16 B.3.1-15 7 08/16 NUH-03-4013 B.3.1-16 7 08/16 DWG: (sh. 5 of 6) 0 8/9/16 B.3.1-17 7 08/16 NUH-03-4013 B.3.1-18 7 08/16 DWG: (sh. 6 of 6) 0 8/9/16 B.3.1-19 7 08/16 NUH-03-4013 B.3.1-20 7 08/16 B.3.1-21 7 08/16 B.2.1-1 7 08/16 B.3.1-22 7 08/16 B.2.1-2 7 08/16 B.3.1-23 7 08/16 B.2.1-3 7 08/16 B.3.1-24 7 08/16 B.2.1-4 7 08/16 B.3.1-25 7 08/16 B.2.1-5 7 08/16 B.3.1-26 7 08/16 B.2.1-6 7 08/16 B.3.1-27 7 08/16 B.2.1-7 7 08/16 B.3.1-28 7 08/16 B.2.1-8 7 08/16 B.3.1-29 7 08/16 B.2.1-9 7 08/16 B.3.1-30 7 08/16 B.2.1-10 7 08/16 B.3.1-31 7 08/16 B.2.1-11 7 08/16 B.3.1-32 7 08/16 B.2.1-12 7 08/16 B.3.1-33 7 08/16 B.2.1-13 7 08/16 B.3.1-34 7 08/16 B.2.1-14 7 08/16 B.3.1-35 7 08/16 B.2.1-15 7 08/16 B.3.1-36 7 08/16 B.2.2-1 7 08/16 B.3.1-37 7 08/16 B.2.2-2 7 08/16 B.3.1-38 7 08/16 B.2.2-3 7 08/16 B.3.1-39 7 08/16 B.2.2-4 7 08/16 B.3.1-40 7 08/16 B.2.3-1 7 08/16 B.3.1-41 7 08/16 B.2.3-2 7 08/16 B.3.2-1 7 08/16 B.2.3-3 7 08/16 B.3.2-2 7 08/16 B.2.3-4 7 08/16 B.3.2-3 7 08/16 B.2.4-1 7 08/16 B.3.2-4 7 08/16 B.2.5-1 7 08/16 B.3.3-1 7 08/16 B.2.5-2 7 08/16 B.3.3-2 7 08/16 B.2.5-3 8 08/18 B.3.3-3 7 08/16 B.2.6-1 7 08/16 B.3.3-4 7 08/16 B.2.6-2 7 08/16 B.3.3-5 7 08/16 B.3.3-6 7 08/16 B.3.1-1 7 08/16 B.3.3-7 7 08/16 B.3.1-2 7 08/16 B.3.3-8 7 08/16 B.3.1-3 7 08/16 B.3.3-9 7 08/16 B.3.1-4 7 08/16 B.3.4-1 7 08/16 B.3.1-5 7 08/16 B.3.4-2 7 08/16 B.3.1-6 7 08/16 B.3.4-3 7 08/16 B.3.1-7 7 08/16 B.3.4-4 7 08/16 B.3.1-8 7 08/16 B.3.4-5 7 08/16 B.3.1-9 7 08/16 B.3.4-6 7 08/16 B.3.1-10 7 08/16 B.3.4-7 7 08/16 B.3.1-11 7 08/16 B.3.4-8 7 08/16 B.3.1-12 7 08/16 ANUH-01.0150 LOEP-17
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.3.4-9 7 08/16 B.3.6-18 7 08/16 B.3.4-10 7 08/16 B.3.6-19 7 08/16 B.3.4-11 7 08/16 B.3.6-20 7 08/16 B.3.4-12 7 08/16 B.3.6-21 7 08/16 B.3.4-13 7 08/16 B.3.6-22 7 08/16 B.3.4-14 7 08/16 B.3.6-23 7 08/16 B.3.4-15 7 08/16 B.3.6-24 7 08/16 B.3.4-16 7 08/16 B.3.6-25 7 08/16 B.3.4-17 7 08/16 B.3.6-26 7 08/16 B.3.5-1 7 08/16 B.3.6-27 7 08/16 B.3.5-2 7 08/16 B.3.6-28 7 08/16 B.3.5-3 7 08/16 B.3.6-29 7 08/16 B.3.5-4 7 08/16 B.3.6-30 7 08/16 B.3.5-5 7 08/16 B.3.6-31 7 08/16 B.3.5-6 7 08/16 B.3.6-32 7 08/16 B.3.5-7 7 08/16 B.3.6-33 7 08/16 B.3.5-8 7 08/16 B.3.6-34 7 08/16 B.3.5-9 7 08/16 B.3.6-35 7 08/16 B.3.5-10 7 08/16 B.3.6-36 7 08/16 B.3.5-11 7 08/16 B.3.6-37 7 08/16 B.3.5-12 7 08/16 B.3.6-38 7 08/16 B.3.5-13 7 08/16 B.3.6-39 7 08/16 B.3.5-14 7 08/16 B.3.6-40 7 08/16 B.3.5-15 7 08/16 B.3.6-41 7 08/16 B.3.5-16 7 08/16 B.3.6-42 7 08/16 B.3.5-17 7 08/16 B.3.6-43 7 08/16 B.3.5-18 7 08/16 B.3.6-44 7 08/16 B.3.5-19 7 08/16 B.3.6-45 7 08/16 B.3.5-20 7 08/16 B.3.6-46 7 08/16 B.3.5-21 7 08/16 B.3.6-47 7 08/16 B.3.5-22 7 08/16 B.3.6-48 7 08/16 B.3.5-23 7 08/16 B.3.6-49 7 08/16 B.3.5-24 7 08/16 B.3.6-50 7 08/16 B.3.6-1 7 08/16 B.3.6-51 7 08/16 B.3.6-2 7 08/16 B.3.6-52 7 08/16 B.3.6-3 7 08/16 B.3.6-53 7 08/16 B.3.6-4 7 08/16 B.3.6-54 7 08/16 B.3.6-5 7 08/16 B.3.6-55 7 08/16 B.3.6-6 7 08/16 B.3.6-56 7 08/16 B.3.6-7 7 08/16 B.3.6-57 7 08/16 B.3.6-8 7 08/16 B.3.6-58 7 08/16 B.3.6-9 7 08/16 B.3.6-59 7 08/16 B.3.6-10 7 08/16 B.3.6-60 7 08/16 B.3.6-11 7 08/16 B.3.6-61 7 08/16 B.3.6-12 7 08/16 B.3.6-62 7 08/16 B.3.6-13 7 08/16 B.3.6-63 7 08/16 B.3.6-14 7 08/16 B.3.6-64 7 08/16 B.3.6-15 7 08/16 B.3.6-65 7 08/16 B.3.6-16 7 08/16 B.3.6-66 7 08/16 B.3.6-17 7 08/16 B.3.6-67 7 08/16 ANUH-01.0150 LOEP-18
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.3.6-68 7 08/16 B.4.4-16 7 08/16 B.3.6-69 7 08/16 B.4.4-17 7 08/16 B.3.6-70 7 08/16 B.4.4-18 7 08/16 B.3.6-71 7 08/16 B.4.4-19 7 08/16 B.3.6-72 7 08/16 B.4.5-1 7 08/16 B.3.6-73 7 08/16 B.4.5-2 7 08/16 B.3.6-74 7 08/16 B.4.5-3 7 08/16 B.3.6-75 7 08/16 B.4.5-4 7 08/16 B.3.6-76 7 08/16 B.4.5-5 7 08/16 B.3.6-77 7 08/16 B.4.5-6 7 08/16 B.3.6-78 7 08/16 B.4.5-7 7 08/16 B.3.6-79 7 08/16 B.4.5-8 7 08/16 B.3.6-80 7 08/16 B.4.5-9 7 08/16 B.3.6-81 7 08/16 B.4.5-10 7 08/16 B.3.6-82 7 08/16 B.4.5-11 7 08/16 B.3.7-1 7 08/16 B.4.5-12 7 08/16 B.3.7-2 7 08/16 B.4.5-13 7 08/16 B.3.7-3 7 08/16 B.4.5-14 7 08/16 B.3.7-4 7 08/16 B.4.5-15 7 08/16 B.4.5-16 7 08/16 B.4-1 7 08/16 B.4.5-17 7 08/16 B.4.1-1 7 08/16 B.4.5-18 7 08/16 B.4.1-2 7 08/16 B.4.5-19 7 08/16 B.4.1-3 7 08/16 B.4.5-20 7 08/16 B.4.1-4 7 08/16 B.4.5-21 7 08/16 B.4.1-5 7 08/16 B.4.5-22 7 08/16 B.4.2-1 7 08/16 B.4.5-23 7 08/16 B.4.2-2 7 08/16 B.4.5-24 7 08/16 B.4.2-3 7 08/16 B.4.5-25 7 08/16 B.4.2-4 7 08/16 B.4.5-26 7 08/16 B.4.2-5 7 08/16 B.4.5-27 7 08/16 B.4.2-6 7 08/16 B.4.5-28 7 08/16 B.4.2-7 7 08/16 B.4.5-29 7 08/16 B.4.3-1 7 08/16 B.4.5-30 7 08/16 B.4.3-2 7 08/16 B.4.5-31 7 08/16 B.4.4-1 7 08/16 B.4.5-32 7 08/16 B.4.4-2 7 08/16 B.4.5-33 7 08/16 B.4.4-3 7 08/16 B.4.5-34 7 08/16 B.4.4-4 7 08/16 B.4.5-35 7 08/16 B.4.4-5 7 08/16 B.4.5-36 7 08/16 B.4.4-6 7 08/16 B.4.5-37 7 08/16 B.4.4-7 7 08/16 B.4.5-38 7 08/16 B.4.4-8 7 08/16 B.4.5-39 7 08/16 B.4.4-9 7 08/16 B.4.5-40 7 08/16 B.4.4-10 7 08/16 B.4.5-41 7 08/16 B.4.4-11 7 08/16 B.4.5-42 7 08/16 B.4.4-12 7 08/16 B.4.5-43 7 08/16 B.4.4-13 7 08/16 B.4.6-1 7 08/16 B.4.4-14 7 08/16 B.4.6-2 7 08/16 B.4.4-15 7 08/16 B.4.6-3 7 08/16 ANUH-01.0150 LOEP-19
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.4.6-4 7 08/16 B.4.6-54 7 08/16 B.4.6-5 7 08/16 B.4.6-55 7 08/16 B.4.6-6 7 08/16 B.4.6-56 7 08/16 B.4.6-7 7 08/16 B.4.6-57 7 08/16 B.4.6-8 7 08/16 B.4.6-58 7 08/16 B.4.6-9 7 08/16 B.4.6-59 7 08/16 B.4.6-10 7 08/16 B.4.6-60 7 08/16 B.4.6-11 7 08/16 B.4.6-61 7 08/16 B.4.6-12 7 08/16 B.4.6-62 7 08/16 B.4.6-13 7 08/16 B.4.6-63 7 08/16 B.4.6-14 7 08/16 B.4.6-64 7 08/16 B.4.6-15 7 08/16 B.4.7-1 7 08/16 B.4.6-16 7 08/16 B.4.7-2 7 08/16 B.4.6-17 7 08/16 B.4.7-3 10 03/21 B.4.6-18 7 08/16 B.4.7-4 7 08/16 B.4.6-19 7 08/16 B.4.7-5 7 08/16 B.4.6-20 7 08/16 B.4.7-6 7 08/16 B.4.6-21 7 08/16 B.4.7-7 7 08/16 B.4.6-22 7 08/16 B.4.7-8 7 08/16 B.4.6-23 7 08/16 B.4.8-1 9 03/19 B.4.6-24 7 08/16 B.4.8-2 7 08/16 B.4.6-25 7 08/16 B.4.9-1 7 08/16 B.4.6-26 7 08/16 B.4.9-2 7 08/16 B.4.6-27 7 08/16 B.4.9-3 7 08/16 B.4.6-28 7 08/16 B.4.9-4 7 08/16 B.4.6-29 7 08/16 B.4.9-5 7 08/16 B.4.6-30 7 08/16 B.4.9-6 7 08/16 B.4.6-31 7 08/16 B.4.9-7 7 08/16 B.4.6-32 7 08/16 B.4.10-1 7 08/16 B.4.6-33 7 08/16 B.4.10-2 7 08/16 B.4.6-34 7 08/16 B.4.10-3 7 08/16 B.4.6-35 7 08/16 B.4.6-36 7 08/16 B.5-1 7 08/16 B.4.6-37 7 08/16 B.5-2 7 08/16 B.4.6-38 7 08/16 B.5.1-1 7 08/16 B.4.6-39 7 08/16 B.5.1-2 7 08/16 B.4.6-40 7 08/16 B.5.2-1 7 08/16 B.4.6-41 7 08/16 B.5.2-2 7 08/16 B.4.6-42 7 08/16 B.5.2-3 7 08/16 B.4.6-43 7 08/16 B.5.2-4 7 08/16 B.4.6-44 7 08/16 B.5.2-5 7 08/16 B.4.6-45 7 08/16 B.5.2-6 7 08/16 B.4.6-46 7 08/16 B.5.2-7 7 08/16 B.4.6-47 7 08/16 B.5.2-8 7 08/16 B.4.6-48 7 08/16 B.5.2-9 7 08/16 B.4.6-49 7 08/16 B.5.2-10 7 08/16 B.4.6-50 7 08/16 B.5.2-11 7 08/16 B.4.6-51 7 08/16 B.5.3-1 7 08/16 B.4.6-52 7 08/16 B.5.3-2 7 08/16 B.4.6-53 7 08/16 B.5.3-3 7 08/16 ANUH-01.0150 LOEP-20
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.5.4-1 7 08/16 B.5.5-44 7 08/16 B.5.4-2 7 08/16 B.5.5-45 7 08/16 B.5.4-3 7 08/16 B.5.5-46 7 08/16 B.5.4-4 7 08/16 B.5.5-47 7 08/16 B.5.4-5 7 08/16 B.5.5-48 7 08/16 B.5.4-6 7 08/16 B.5.5-49 7 08/16 B.5.4-7 7 08/16 B.5.5-50 7 08/16 B.5.5-1 7 08/16 B.5.5-51 7 08/16 B.5.5-2 7 08/16 B.5.5-52 7 08/16 B.5.5-3 7 08/16 B.5.5-53 7 08/16 B.5.5-4 7 08/16 B.5.5-54 7 08/16 B.5.5-5 7 08/16 B.5.5-55 7 08/16 B.5.5-6 7 08/16 B.5.5-56 7 08/16 B.5.5-7 7 08/16 B.5.5-57 7 08/16 B.5.5-8 7 08/16 B.5.5-58 7 08/16 B.5.5-9 7 08/16 B.5.5-59 7 08/16 B.5.5-10 7 08/16 B.5.5-60 7 08/16 B.5.5-11 7 08/16 B.5.5-61 7 08/16 B.5.5-12 7 08/16 B.5.5-62 7 08/16 B.5.5-13 7 08/16 B.5.5-63 7 08/16 B.5.5-14 7 08/16 B.5.5-64 7 08/16 B.5.5-15 7 08/16 B.5.5-65 7 08/16 B.5.5-16 7 08/16 B.5.5-66 7 08/16 B.5.5-17 7 08/16 B.5.5-67 7 08/16 B.5.5-18 7 08/16 B.5.5-68 7 08/16 B.5.5-19 7 08/16 B.5.5-69 7 08/16 B.5.5-20 7 08/16 B.5.5-70 7 08/16 B.5.5-21 7 08/16 B.5.5-71 7 08/16 B.5.5-22 7 08/16 B.5.5-72 7 08/16 B.5.5-23 7 08/16 B.5.5-73 7 08/16 B.5.5-24 7 08/16 B.5.5-74 7 08/16 B.5.5-25 7 08/16 B.5.5-75 7 08/16 B.5.5-26 7 08/16 B.5.5-76 7 08/16 B.5.5-27 7 08/16 B.5.5-77 7 08/16 B.5.5-28 7 08/16 B.5.5-78 7 08/16 B.5.5-29 7 08/16 B.5.5-79 7 08/16 B.5.5-30 7 08/16 B.5.5-80 7 08/16 B.5.5-31 7 08/16 B.5.5-81 7 08/16 B.5.5-32 7 08/16 B.5.5-82 7 08/16 B.5.5-33 7 08/16 B.5.5-83 7 08/16 B.5.5-34 7 08/16 B.5.5-84 7 08/16 B.5.5-35 7 08/16 B.5.5-85 7 08/16 B.5.5-36 7 08/16 B.5.5-86 7 08/16 B.5.5-37 7 08/16 B.5.5-87 7 08/16 B.5.5-38 7 08/16 B.5.5-88 7 08/16 B.5.5-39 7 08/16 B.5.5-40 7 08/16 B.6-1 7 08/16 B.5.5-41 7 08/16 B.6.1-1 7 08/16 B.5.5-42 7 08/16 B.6.2-1 7 08/16 B.5.5-43 7 08/16 B.6.3-1 7 08/16 ANUH-01.0150 LOEP-21
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.6.3-2 7 08/16 B.6.6-33 7 08/16 B.6.3-3 7 08/16 B.6.6-34 7 08/16 B.6.4-1 7 08/16 B.6.6-35 7 08/16 B.6.4-2 7 08/16 B.6.6-36 7 08/16 B.6.4-3 7 08/16 B.6.6-37 7 08/16 B.6.4-4 7 08/16 B.6.6-38 7 08/16 B.6.4-5 7 08/16 B.6.6-39 7 08/16 B.6.4-6 7 08/16 B.6.6-40 7 08/16 B.6.4-7 7 08/16 B.6.6-41 7 08/16 B.6.4-8 7 08/16 B.6.6-42 7 08/16 B.6.4-9 7 08/16 B.6.6-43 7 08/16 B.6.4-10 7 08/16 B.6.6-44 7 08/16 B.6.4-11 7 08/16 B.6.6-45 7 08/16 B.6.4-12 7 08/16 B.6.6-46 7 08/16 B.6.4-13 7 08/16 B.6.6-47 7 08/16 B.6.4-14 7 08/16 B.6.6-48 7 08/16 B.6.5-1 7 08/16 B.6.6-49 7 08/16 B.6.5-2 7 08/16 B.6.6-50 7 08/16 B.6.6-1 7 08/16 B.6.6-51 7 08/16 B.6.6-2 7 08/16 B.6.6-52 7 08/16 B.6.6-3 7 08/16 B.6.6-53 7 08/16 B.6.6-4 7 08/16 B.6.6-54 7 08/16 B.6.6-5 7 08/16 B.6.6-55 7 08/16 B.6.6-6 7 08/16 B.6.6-56 7 08/16 B.6.6-7 7 08/16 B.6.6-57 7 08/16 B.6.6-8 7 08/16 B.6.6-9 7 08/16 B.7.1-1 7 08/16 B.6.6-10 7 08/16 B.7.1-2 7 08/16 B.6.6-11 7 08/16 B.7.2-1 7 08/16 B.6.6-12 7 08/16 B.7.3-1 7 08/16 B.6.6-13 7 08/16 B.7.4-1 7 08/16 B.6.6-14 7 08/16 B.6.6-15 7 08/16 B.8-1 7 08/16 B.6.6-16 7 08/16 B.8.1-1 7 08/16 B.6.6-17 7 08/16 B.8.1-2 7 08/16 B.6.6-18 7 08/16 B.8.1-3 7 08/16 B.6.6-19 7 08/16 B.8.1-4 7 08/16 B.6.6-20 7 08/16 B.8.1-5 8 08/18 B.6.6-21 7 08/16 B.8.1-6 8 08/18 B.6.6-22 7 08/16 B.8.1-7 7 08/16 B.6.6-23 7 08/16 B.8.1-8 7 08/16 B.6.6-24 7 08/16 B.8.1-9 7 08/16 B.6.6-25 7 08/16 B.8.1-10 7 08/16 B.6.6-26 7 08/16 B.8.1-11 7 08/16 B.6.6-27 7 08/16 B.8.1-12 7 08/16 B.6.6-28 7 08/16 B.8.1-13 7 08/16 B.6.6-29 7 08/16 B.8.1-14 7 08/16 B.6.6-30 7 08/16 B.8.2-1 9 03/19 B.6.6-31 7 08/16 B.8.2-2 9 03/19 B.6.6-32 7 08/16 B.8.2-2a 9 03/19 ANUH-01.0150 LOEP-22
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date Page or description Rev. Date B.8.2-3 9 03/19 B.10.4-1 7 08/16 B.8.2-4 9 03/19 B.8.2-5 7 08/16 B.11-1 7 08/16 B.8.2-6 7 08/16 B.11.1-1 7 08/16 B.8.2-7 7 08/16 B.11.1-2 7 08/16 B.8.3-1 7 08/16 B.11.1-3 7 08/16 B.8.3-2 8 08/18 B.11.2-1 7 08/16 B.11.2-2 7 08/16 B.9-1 7 08/16 B.11.2-3 7 08/16 B.9.1-1 7 08/16 B.11.2-4 7 08/16 B.9.1-2 7 08/16 B.11.2-5 7 08/16 B.9.1-3 7 08/16 B.11.2-6 7 08/16 B.9.1-4 7 08/16 B.11.2-7 7 08/16 B.9.1-5 7 08/16 B.11.2-8 7 08/16 B.9.1-6 7 08/16 B.11.2-9 7 08/16 B.9.1-7 7 08/16 B.11.2-10 7 08/16 B.9.1-8 7 08/16 B.11.2-11 7 08/16 B.9.1-9 7 08/16 B.11.2-12 7 08/16 B.9.1-10 7 08/16 B.11.2-13 7 08/16 B.9.2-1 7 08/16 B.11.2-14 7 08/16 B.9.3-1 7 08/16 B.11.2-15 7 08/16 B.9.4-1 7 08/16 B.11.2-16 7 08/16 B.9.4-2 7 08/16 B.11.2-17 7 08/16 B.11.2-18 7 08/16 B.10.1-1 7 08/16 B.11.2-19 7 08/16 B.10.1-2 7 08/16 B.11.2-20 7 08/16 B.10.1-3 7 08/16 B.11.2-21 7 08/16 B.10.2-1 7 08/16 B.11.2-22 7 08/16 B.10.2-2 7 08/16 B.11.2-23 7 08/16 B.10.2-3 7 08/16 B.11.2-24 7 08/16 B.10.2-4 7 08/16 B.11.2-25 7 08/16 B.10.2-5 7 08/16 B.11.2-26 7 08/16 B.10.2-6 7 08/16 B.11.2-27 7 08/16 B.10.2-7 7 08/16 B.11.2-28 7 08/16 B.10.2-8 7 08/16 B.11.2-29 7 08/16 B.10.2-9 7 08/16 B.11.2-30 7 08/16 B.10.2-10 7 08/16 B.11.2-31 7 08/16 B.10.2-11 7 08/16 B.11.2-32 7 08/16 B.10.2-12 7 08/16 B.11.2-33 7 08/16 B.10.2-13 7 08/16 B.11.2-34 7 08/16 B.10.2-14 7 08/16 B.11.3-1 7 08/16 B.10.2-15 7 08/16 B.10.2-16 7 08/16 B.12-1 7 08/16 B.10.2-17 7 08/16 B.12-2 7 08/16 B.10.2-18 7 08/16 B.12-3 7 08/16 B.10.3-1 7 08/16 B.12-4 7 08/16 B.10.3-2 7 08/16 B.12-5 9 03/19 B.10.3-3 7 08/16 B.12-6 7 08/16 B.10.3-4 7 08/16 B.12-7 7 08/16 B.10.3-5 7 08/16 B.12-8 7 08/16 ANUH-01.0150 LOEP-23
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 List Of Effective Pages Page or description Rev. Date B.12-9 7 08/16 B.12-10 7 08/16 B.12-11 7 08/16 B.12-12 7 08/16 B.12-13 7 08/16 B.12-14 7 08/16 B.12-15 7 08/16 B.12-16 7 08/16 B.12-17 7 08/16 B.12-18 7 08/16 B.12-19 7 08/16 B.13-1 7 08/16 B.14.1-1 9 03/19 B.14.1-2 9 03/19 B.14.1-3 7 08/16 B.14.2-1 7 08/16 ANUH-01.0150 LOEP-24
Advanced NUHOMS System Updated Final Safety Analysis Report Rev. 12, 03/23 1.5 Supplemental Data 1.5.1 References
[1.1] 10 CFR Part 72, Rules and Regulations, Title 10, Code of Federal Regulations - Energy, U.S. Nuclear Regulatory Commission, Washington, D.C., Licensing Requirements for the Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste.
[1.2] U.S. Nuclear Regulatory Commission, Regulatory Guide 3.61, Standard Format and Content for a Topical Safety Analysis Report for a Spent Fuel Dry Storage Cask, February 1989.
[1.3] U.S. Nuclear Regulatory Commission, Standard Review Plan for Dry Cask Storage Systems, NUREG 1536, U.S. NRC (January 1997).
[1.4] Nuclear Regulatory Commission, Safety Evaluation Report of Safety Analysis Report for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, December 1994, USNRC Docket No. 72-1004, File NUH003.0103.02.
[1.5] TN, Safety Analysis Report for the NUHOMS MP187 Multi-Purpose Cask, NUH-005, Revision 17, July 2003, USNRC Docket No. 71-9255.
[1.6] TN, Updated Final Safety Analysis Report for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 9, February 2006, File NUH003.0103, USNRC Docket No. 72-1004.
[1.7] Rancho Seco Independent Spent Fuel Storage Installation, Final Safety Analysis Report, Revision 0, November 2000, USNRC Docket No. 72-11.
[1.8] 10 CFR Part 71, Rules and Regulations, Title 10, Code of Federal Regulations - Energy, U.S. Nuclear Regulatory Commission, Washington, D.C., Packaging and Transportation of Radioactive Material.
[1.9] NRC Certificate of Compliance 72-1004, NUHOMS General License Spent Fuel Storage System, Amendment No. 8, December 2005.
1.5.2 Drawings
- 24PT1-DSC: NUH-05-4010, Rev. 6 (PROPRIETARY)
- AHSM: NUH-03-4011, Rev. 10 (PROPRIETARY)
ANUH-01.0150 1.5-1
Proprietary and Security Related Information for Drawing NUH-03-4011, Rev. 10 Withheld Pursuant to 10 CFR 2.390
Enclosure 4 to E-62023 Biennial Report of 10 CFR 72.48 Evaluations Performed for CoC 1029 for the Period 11/18/2021 to 3/23/2023 LR No. Description of Change, Test, or Experiment Summary of Evaluation 721029-435 A summary of Revision 1 of this Licensing Review The evaluation summary and conclusions of Revision 1 of this LR remain Rev. 2 (LR) was provided in the previous biennial summary unchanged and are applicable to Revision 2.
report, E-58497, dated November 17, 2021 All eight 72.48 evaluation criteria were met.
(ML21321A039). The purpose of Revision 2 is to reconcile the Revision 1 conclusions with CoC 1029
- This change was incorporated into UFSAR Revision 11.
renewal.
436 The change involves performing Aging Management The evaluation determined that use of the inspection ring assembly would Rev. 1 Program (AMP) related inspections of the external not affect DSC confinement, retrievability or the criticality design surfaces of the 24PT1 dry shielded canisters (DSCs) functions.
on a loaded DSC that has been in storage in an A shielding evaluation was performed for this change. As the DSC is Advanced Horizontal Storage Module (AHSM). The pulled through the inspection ring assembly, a portion of the DSC will no proposed change being addressed is the use of an longer be shielded by the AHSM or TC. To provide shielding between the inspection ring assembly, which involves the AHSM and TC, the inspection ring assembly includes a shielding system temporary removal of the AHSM door, installing a filled with water. The effectiveness of this shielding was determined by temporary shield plug in the AHSM door opening for calculations. A calculation determined a bounding source term for the ALARA purposes, installation of an inspection ring, sites fuel stored in a 24PT1 DSC. Models were developed for each of removal of the temporary shield plug, attaching a sites Unit-1 spent fuel assemblies stored at the independent spent fuel transfer cask (TC) to the inspection ring, pulling the storage installation (ISFSI) assuming the DSC has been in storage for a DSC through the inspection ring into the TC while minimum of 15 years. The bounding source term was then used to conducting the nondestructive examination (NDE) determine the dose rate at the controlled area boundary distance from the inspections, and reversing the process to return the shielding system. An off-site dose calculation that considered the dose DSC and AHSM to their design configuration. While from 12 AHSMs containing greater than Class C (GTCC) waste and the DSC and AHSM are returned to their design loaded dry cask systems determined an annual dose at the owner-configuration following the NDE inspection, the controlled boundary. Based on the above the DSCs could be in the installation of the inspection ring assembly represents inspection ring assembly for a total of 1,768 hours0.00889 days <br />0.213 hours <br />0.00127 weeks <br />2.92224e-4 months <br /> and still meet the a temporary configuration to the Standardized 72.104 limit of 25 mrem/yr to a real individual. Use of administrative Advanced NUHOMS system as described in the CoC controls to ensure that the shielding system is filled with water, e.g., drain 1029 UFSAR.
lines are disconnected, the shielding system ensures that the 72.104 limits are maintained. Administrative controls in the procedure(s) requiring that only the 24PT1 DSCs that have been in storage for at least Page 1 of 4
Enclosure 4 to E-62023 LR No. Description of Change, Test, or Experiment Summary of Evaluation 721029-15 years are inspected, and the shielding system drain lines are disconnected coupled with the above calculations ensure that the radiation shielding design function is maintained.
A structural evaluation was performed. The weight of the HSM door is a sufficiently small proportion of the total HSM weight such that the HSM structural response to accident conditions, including overturning and sliding due to seismic loads, is not impacted with the door removed and/or the temporary shield plug installed. Removing the HSM door and installing the temporary shield plug could impact the structural function of the HSM, i.e., tornado missile protection. During the normal loading/unloading of an AHSM, there is a period of time when the DSC is not protected from tornado missiles, i.e., the AHSM door is not installed and the TC is not connected to the AHSM. The installation/removal of the inspection ring assembly involves a very similar sequence of events in that there is a comparable period of time when the AHSM door is not installed and the TC is not connected to the inspection ring assembly.
During this period, a temporary shield plug is installed in the AHSM doorway for ALARA purposes. While the temporary shield plug has a Safety Classification of B no explicit structural analysis was performed to evaluate the temporary shield plug for tornado wind and missile protection. However, tornado wind and missile loadings do not apply in this portion of the temporary configuration since administrative controls are credited to ensure that the HSM door is installed, or the TC is connected to the inspection ring assembly, during the occurrence of a tornado event and, thus, the temporary shield plug is not relied upon for tornado protection. The temporary shield plug will sit in the AHSM doorway, i.e., a maximum of 2 inches from the DSC, So, if it were to tip into the HSM, there would be no appreciable impact force on DSC and, therefore, would not challenge the DSCs structural integrity function.
A calculation demonstrated that the inspection ring cask restraint system was capable of meeting the AISC Manual of Steel Construction allowable stresses limits during insertion and retrieval of the DSC. A calculation also demonstrated that the mounting bracket and shielding system of the inspection ring assembly met the applicable stress limits considering dead loads, hydrostatic loads, handling loads, and tornado loads. Note Page 2 of 4
Enclosure 4 to E-62023 LR No. Description of Change, Test, or Experiment Summary of Evaluation 721029-that seismic loads are not considered because:
- The inspection ring restraints (both inspection ring assembly to the HSM and TC to the inspection ring assembly) are equivalent to the original TC to HSM restraints, which are not seismically qualified. Therefore, the inspection ring assembly restraints do not need to be seismically qualified.
- The USFAR does not contain an evaluation of a seismic event while loading or unloading a DSC from an AHSM. The use of the inspection ring assembly does not alter this evolution other than the TC is connected to the inspection ring assembly, which is connected to the AHSM. The inspection ring assembly is not relied upon to provide structural support to the DSC during the transfer. Since the UFSAR does not evaluate a seismic event during loading/unloading operations, there is no UFSAR requirement to evaluate a seismic event while the Inspection Ring Assembly is attached.
- During a seismic event, there is the potential that the inspection ring assembly could impact a DSC, but the gap between the shielding system and the DSC is small and the impact would generate no appreciable dynamic force. Therefore, there is no appreciable impact force by the shielding system to the DSC.
Use of the tornado protection administrative controls in the procedure(s) and the above structural evaluations ensure that the structural integrity design function is maintained.
A thermal evaluation was performed. The Inspection ring assembly will be positioned against the AHSM front wall blocking inlet air flow of AHSMs. The Inspection Ring Assembly completely blocks the inlet of the AHSM loaded with the DSC being inspected. In order to maintain continuous airflow, the concrete block below the inlet vent is removed.
The removal of this block increases the size of the inlet and thus improves the thermal performance of the AHSM loaded with the DSC to be inspected. The adjacent AHSM inlets are partially blocked (30.3%
blockage) by the inspection ring assembly.
Page 3 of 4
Enclosure 4 to E-62023 LR No. Description of Change, Test, or Experiment Summary of Evaluation 721029-A calculation performed a thermal analysis of this configuration by assuming 60.6% blockage of the affected inlet vents (which bounds the actual condition of 30.3% partially blocked vent). The analysis recognized that the sites fuel would have been in storage for many years and thus assumed a DSC decay heat load of 6 kw. The analysis determined a DSC shell temperature of 215 °F which is much less than the Design Basis temperature of 332 °F reported in Table 4.4-4 of the UFSAR.
Placing administrative controls in the procedure(s) to ensure the decay heat is less than 6 kw, removal of the concrete block below the inlet vent, and the above calculation ensure that the heat removal design function is maintained.
All eight 72.48 evaluation criteria were met.
- No associated UFSAR changes were required.
Page 4 of 4