Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 1166165 COSR 15-Deep Soil-Westside Park Lot MJ7951AE U-233/234 9.46E-01 +-

1.80E-01

< pCi/g 93%

4.86E-02 1.00E+00 U-235/236 4.29E-02 +-

3.20E-02

< pCi/g 93%

4.46E-02 1.00E+00 U-238 1.17E+00 +-

2.10E-01 pCi/g 93%

6.16E-02 1.00E+00 15-Deep Soil-Westside Park Lot DU MJ7951AJ U-233/234 7.90E-01 +-

1.50E-01

< pCi/g 92%

4.85E-02 1.00E+00 1.3 U-235/236 2.06E-02 +-

1.80E-02

< pCi/g 92%

2.40E-02 1.00E+00 1.2 U-238 1.02E+00 +-

1.90E-01 pCi/g 92%

5.93E-02 1.00E+00 1.0 1166182 ADSO 17 -SMEAR-WASTE RM BLUE CONTAINER MJ8A01AC Pu-238

-3.73E-06 +-

2.10E-02

< pCi/sample 100%

6.34E-02 Pu-239/40

-4.31E-03 +-

1.90E-02

< pCi/sample 100%

5.16E-02 6.30E-01 1166166 RL-ALP-002 15-DEEP SOIL WEST SIDE PARK LOT MJ7951AD Pu-238 3.02E-03 +-

1.60E-02

< pCi/g 91%

3.25E-02 6.00E-01 Pu-239/40 3.01E-03 +-

1.30E-02

< pCi/g 91%

2.80E-02 6.00E-01 15-DEEP SOIL WEST SIDE PARK LOT DU MJ7951AK Pu-238

-3.32E-03 +- 9.40E-03

< pCi/g 100%

2.44E-02 6.00E-01 0.7 Pu-239/40 6.63E-03 +- 1.20E-02

< pCi/g 100%

2.44E-02 6.00E-01 0.4 1166180 RAO-TH ISO BY ALPHA 17-SMEAR-WASTE RM BLUE CONTAINER MJ8A01AE Th-228

-3.42E-03 +- 1.80E-02

< pCi/sample 100%

4.83E-02 6.00E-01 Th-230 7.38E-02 +- 5.10E-02

< pCi/sample 100%

3.93E-02 6.00E-01 Th-232 0.00E+00 +- 1.70E-02

< pCi/sample 100%

3.93E-02 6.00E-01 1166181 RAO-U ISO BY ALPHA 17-SMEAR-WASTE RM BLUE CONTAINER MJ8A01AD U-233/234 1.83E+01 +- 3.10E+00 pCi/sample 94%

9.32E-02 3.00E+00 U-235/236 9.65E-01 +- 3.10E-01

< pCi/sample 94%

1.10E-01 3.00E+00 U-238 1.90E+01 +- 3.20E+00 pCi/sample 94%

9.32E-02 3.00E+00 Result+-Uncertainty ( 2s) 1 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 1166161 E901.1 06-SURF SOIL-SOUTHSIDE MJ79J1AA Ac-228 8.70E-01 +- 2.00E-01 pCi/g 1.41 E-01 Bi-214 4.97E-01 +- 1.20E-01 pCi/g 7.86E-02 Cd-109 1.09E+00 +-

5.00E-01

< pCi/g 8.45E-01 Co-57

-4.44E-02 +-

1.40E-01

< pCi/g 2.37E-01 Cs-137 3.72E-02 +-

2.60E-02

< pCi/g 4.69E-02 2.00E-01 K-40 8.23E+00 +- 1.20E+00 pCi/g 3.69E-01 Pb-212 7.00E-01 +-

1.10E-01 pCi/g 6.04E-02 Pb-214 5.61E-01 +-

1.20E-01 pCi/g 7.58E-02 Ra-224 7.28E-01 +-

1.10E-01 pCi/g 6.29E-02 Ra-226 4.97E-01 +-

1.20E-01 pCi/g 7.86E-02 Ra-228 8.81E-01 +-

2.00E-01 pCi/g 1.43E-01 Th-228 7.16E-01 +-

1.80E-01 pCi/g 1.18E-01 Th-232 7.49E-01 +-

2.00E-01 pCi/g 2.36E-01 TI-208 2.47E-01 +-

6.40E-02 pCi/g 4.07E-02 U-233/234 6.62E-01 +-

1.60E-01 pCi/g 1.51E-01 U-238 5.61E-01 +-

1.20E-01 pCi/g 7.58E-02 06-SURF SOIL-SOUTHSIDE DUP MJ79J1AC Ac-228 8.05E-01 +-

1.60E-01 pCi/g 1.05E-01 0.5 Bi-214 5.36E-01 +-

1.00E-01 pCi/g 6.15E-02 0.5 Cd-109 1.31E+00 +-

5.20E-01 pCi/g 5.04E-01 0.6 Co-57 6.99E-02 +-

1.00E-01

< pCi/g 1.81E-01 1.3 Cs-137 1.84E-02 +-

2.00E-02

< pCi/g 3.69E-02 2.00E-01 1.2 K-40 8.55E+00 +- 1.20E+00 pCi/g 2.92E-01 0.4 Pb-212 7.08E-01 +-

1.10E-01 pCi/g 7.41E-02 0.1 Pb-214 5.77E-01 +-

1.00E-01 pCi/g 6.00E-02 0.2 Ra-224 7.36E-01 +-

1.20E-01 pCi/g 7.72E-02 0.1 Ra-226 5.36E-01 +-

1.00E-01 pCi/g 6.15E-02 0.5 Ra-228 8.16E-01 +-

1.60E-01 pCi/g 1.06E-01 0.5 Th-228 7.47E-01 +-

1.50E-01 pCi/g 9.19E-02 0.3 Th-232 6.76E-01 +-

2.20E-01 pCi/g 1.94E-01 0.5 TI-208 2.58E-01 +-

5.20E-02 pCi/g 3.17E-02 0.3 U-233/234 5.92E-01 +-

1.60E-01 pCi/g 1.12E-01 0.6 U-238 5.77E-01 +-

1.00E-01 pCi/g 6.00E-02 0.2 2 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 07 -DEEPSOIL-SOUTHSIDE MJ79K1AA Ac-228 8.70E-01 +-

1.70E-01 pCi/g 8.77E-02 Bi-214 6.39E-01 +-

1.10E-01 pCi/g 4.92E-02 Cd-109 1.45E+00 +-

6.50E-01 pCi/g 7.23E-01 Co-57 5.26E-02 +-

8.60E-02

< pCi/g 1.53E-01 Cs-137

-7.91E-03 +-

1.60E-02

< pCi/g 2.68E-02 2.00E-01 K-40 1.41E+01 +-

1.90E+00 pCi/g 2.10E-01 Pb-212 7.77E-01 +-

1.10E-01 pCi/g 3.80E-02 Pb-214 6.83E-01 +-

1.20E-01 pCi/g 5.35E-02 Ra-224 8.08E-01 +-

1.20E-01 pCi/g 3.95E-02 Ra-226 6.39E-01 +-

1.10E-01 pCi/g 4.92E-02 Ra-228 8.81E-01 +-

1.70E-01 pCi/g 8.88E-02 Th-228 7.29E-01 +-

1.30E-01 pCi/g 7.69E-02 Th-232 8.88E-01 +-

1.80E-01 pCi/g 1.56E-01 TI-208 2.52E-01 +-

4.40E-02 pCi/g 2.65E-02 U-233/234 8.31E-01 +-

1.50E-01 pCi/g 8.97E-02 U-238 6.83E-01 +-

1.20E-01 pCi/g 5.35E-02 08-SURF SOIL-EASTSIDE MJ79L1AA Cd-109 1.05E-01 +-

4.40E-01

< pCi/g 7.38E-01 Co-57 7.13E-02 +-

1.10E-01

< pCi/g 1.82E-01 C8-137 9.03E-03 +-

1.60E-02

< pCi/g 2.91E-02 2.00E-01 K-40 6.00E+00 +-

8.60E-01 pCi/g 2.18E-01 Pb-212 3.40E-01 +-

6.40E-02 pCi/g 4.20E-02 Pb-214 3.84E-01 +-

8.40E-02 pCi/g 5.20E-02 Ra-224 3.54E-01 +-

6.70E-02 pCi/g 4.37E-02 Ra-226 3.80E-01 +-

7.50E-02 pCi/g 4.85E-02 Ra-228 3.97E-01 +-

1.00E-01

< pCi/g 1.58E-01 Th-228 2.84E-01 +-

8.50E-02 pCi/g 7.26E-02 Th-232 3.44E-01 +-

1.70E-01 pCi/g 1.52E-01 TI-208 9.81E-02 +-

2.90E-02 pCi/g 2.51E-02 U-233/234 3.84E-01 +-

1.20E-01 pCi/g 1.09E-01 U-238 3.84E-01 +-

8.40E-02 pCi/g 5.20E-02 3 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 09-DEEPSOIL-EASTSIDE MJ79M1AA Ac-228 6.57E-01 +-

2.10E-01 pCi/g 1.35E-01 Bi-214 5.31E-01 +-

1.10E-01 pCi/g 6.86E-02 Cd-109 1.87E+00 +-

6.90E-01 pCi/g 8.23E-01 Co-57 1.85E-03 +-

1.30E-01

< pCi/g 2.13E-01 Cs-137

-4.98E-03 +-

2.40E-02

< pCi/g 4.09E-02 2.00E-01 K-40 1.30E+01 +-

1.80E+00 pCi/g 3.39E-01 Pb-212 7.46E-01 +-

1.10E-01 pCi/g 5.50E-02 Pb-214 6.49E-01 +-

1.20E-01 pCi/g 6.72E-02 Ra-224 7.76E-01 +-

1.20E-01 pCi/g 5.72E-02 Ra-226 5.31E-01 +-

1.10E-01 pCi/g 6.86E-02 Ra-228 6.66E-01 +-

2.20E-01 pCi/g 1.37E-01 Th-228 6.79E-01 +-

1.60E-01 pCi/g 1.09E-01 Th-232 7.33E-01 +-

2.00E-01 pCi/g 2.03E-01 TI-208 2.35E-01 +-

5.40E-02 pCi/g 3.75E-02 U-233/234 7.14E-01 +-

1.70E-01 pCi/g 1.28E-01 U-238 6.49E-01 +-

1.20E-01 pCi/g 6.72E-02 10-SURF SOIL-RX HIGHBAY MJ79N1AA Cd-109 6.06E-01 +-

6.30E-01

< pCi/g 9.20E-01 Co-57

-3.98E-02 +-

1.30E-01

< pCi/g 2.12E-01 Cs-137 5.02E-03 +-

1.80E-02

< pCi/g 3.05E-02 2.00E-01 K-40 1.24E+01 +-

1.60E+00 pCi/g 2.28E-01 Pb-212 6.41E-01 +-

1.10E-01 pCi/g 4.94E-02 Pb-214 6.64E-01 +-

1.00E-01 pCi/g 5.58E-02 Ra-224 6.67E-01 +-

1.20E-01 pCi/g 5.14E-02 Ra-226 5.75E-01 +-

9.80E-02 pCi/g 5.24E-02 Ra-228 5.57E-01 +-

1.30E-01

< pCi/g 1.85E-01 Th-228 4.79E-01 +-

1.30E-01 pCi/g 7.95E-02 Th-232 5.84E-01 +-

2.00E-01 pCi/g 1.74E-01 TI-208 1.66E-01 +-

4.40E-02 pCi/g 2.74E-02 U-233/234 5.54E-01 +-

1.40E-01 pCi/g 1.31E-01 U-238 6.64E-01 +-

1.00E-01 pCi/g 5.58E-02 4 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 11-DEEPSOIL-RX HIGHBAY MJ79P1AC Ac-228 8.56E-01 +-

2.20E-01 pCi/g 1.55E-01 Bi-214 6.58E-01 +-

1.30E-01 pCi/g 7.66E-02 Cd-109 2.09E+00 +-

8.70E-01 pCi/g 7.63E-01 Co-57

-1.03E-01 +-

1.40E-01

< pCi/g 2.32E-01 Cs-137

-1.62E-03 +-

2.60E-02

< pCi/g 4.52E-02 2.00E-01 K-40 1.89E+01 +-

2.50E+00 pCi/g 3.98E-01 Pb-212 1.05E+00 +-

1.50E-01 pCi/g 6.06E-02 Pb-214 6.35E-01 +-

1.20E-01 pCi/g 7.42E-02 Ra-224 1.09E+00 +-

1.60E-01 pCi/g 6.31E-02 Ra-226 6.58E-01 +-

1.30E-01 pCi/g 7.67E-02 Ra-228 8.67E-01 +-

2.30E-01 pCi/g 1.57E-01 Th-228 9.48E-01 +-

1.90E-01 pCi/g 1.21E-01 Th-232 1.17E+00 +-

2.70E-01 pCi/g 2.23E-01 TI-208 3.27E-01 +-

6.70E-02 pCi/g 4.17E-02 U-233/234 8.08E-01 +-

1.80E-01 pCi/g 1.40E-01 U-238 6.35E-01 +-

1.20E-01 pCi/g 7.42E-02 12-SURF SOIL-NORTHSIDE MJ79V1AC Bi-214 4.74E-01 +-

8.70E-02 pCi/g 5.61E-02 Cd-109 1.66E-01 +-

4.90E-01

< pCi/g 8.21E-01 Co-57 7.43E-02 +-

1.20E-01

< pCi/g 2.01E-01 Cs-137

-6.86E-03 +-

1.80E-02

< pCi/g 3.02E-02 2.00E-01 K-40 7.99E+00 +-

1.10E+00 pCi/g 2.42E-01 Pb-212 4.92E-01 +-

8.20E-02 pCi/g 4.58E-02 Pb-214 5.17E-01 +-

8.60E-02 pCi/g 5.58E-02 Ra-224 5.13E-01 +-

8.50E-02 pCi/g 4.78E-02 Ra-226 4.74E-01 +-

8.70E-02 pCi/g 5.61E-02 Ra-228 5.00E-01 +-

1.20E-01

< pCi/g 1.79E-01 Th-228 3.60E-01 +-

1.00E-01 pCi/g 7.25E-02 Th-232 2.81E-01 +-

1.40E-01 pCi/g 1.69E-01 TI-208 1.24E-01 +-

3.50E-02 pCi/g 2.50E-02 U-233/234 4.85E-01 +-

1.30E-01 pCi/g 1.24E-01 U-238 5.17E-01 +-

8.60E-02 pCi/g 5.58E-02 5 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 13-DEEPSOIL-NORTHSIDE MJ79W1AA Ac-228 9.59E-01 +-

2.30E-01 pCi/g 1.44E-01 Bi-214 6.83E-01 +-

1.20E-01 pCi/g 7.11E-02 Cd-109 1.39E+00 +-

8.20E-01 pCi/g 1.14E+00 Co-57 5.17E-02 +-

1.40E-01

< pCi/g 2.38E-01 Cs-137

-5.92E-03 +-

2.30E-02

< pCi/g 3.86E-02 2.00E-01 K-40 1.63E+01 +-

2.30E+00 pCi/g 3.12E-01 Pb-212 8.46E-01 +-

1.30E-01 pCi/g 8.27E-02 Pb-214 7.11E-01 +-

1.30E-01 pCi/g 6.85E-02 Ra-224 8.82E-01 +-

1.40E-01 pCi/g 8.63E-02 Ra-226 6.83E-01 +-

1.20E-01 pCi/g 7.11E-02 Ra-228 9.72E-01 +-

2.30E-01 pCi/g 1.46E-01 Th-228 8.76E-01 +-

1.70E-01 pCi/g 1.03E-01 Th-232 8.86E-01 +-

2.40E-01 pCi/g 2.11E-01 TI-208 3.02E-01 +-

5.80E-02 pCi/g 3.55E-02 U-233/234 8.13E-01 +-

2.10E-01 pCi/g 1.48E-01 U-238 7.11E-01 +-

1.30E-01 pCi/g 6.85E-02 14-SURF SOIL-WESTSIDEPARKLOT MJ7931AA Cd-109 4.73E-01 +-

3.80E-01

< pCi/g 6.48E-01 Co-57 3.81E-02 +-

9.30E-02

< pCi/g 1.59E-01 Cs-137 3.87E-03 +-

1.30E-02

< pCi/g 2.34E-02 2.00E-01 K-40 4.42E+00 +-

6.80E-01 pCi/g 1.97E-01 Pb-212 3.64E-01 +-

7.00E-02 pCi/g 4.02E-02 Pb-214 3.07E-01 +-

6.80E-02 pCi/g 4.70E-02 Ra-224 3.80E-01 +-

7.30E-02 pCi/g 4.19E-02 Ra-226 2.64E-01 +-

5.90E-02

< pCi/g 7.85E-02 Ra-228 2.67E-01 +-

7.20E-02

< pCi/g 1.33E-01 Th-228 3.23E-01 +-

8.30E-02 pCi/g 6.64E-02 TI-208 1.11E-01 +-

2.80E-02 pCi/g 2.29E-02 U-233/234 2.46E-01 +-

8.30E-02 pCi/g 9.75E-02 U-238 3.07E-01 +-

6.80E-02 pCi/g 4.70E-02 6 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 15-DEEPSOIL-WEST SIDE PARK LOT MJ7951AC Ac-228 6.91E-01 +-

2.80E-01 pCi/g 2.68E-01 Bi-214 7.52E-01 +-

1.60E-01 pCi/g 1.10E-01 Cd-109

-5.41E-01 +-

7.70E-01

< pCi/g 1.26E+00 Co-57

-9.95E-02 +-

1.60E-01

< pCi/g 2.62E-01 Cs-137 9.82E-03 +-

3.90E-02

< pCi/g 6.85E-02 2.00E-01 K-40 1.80E+01 +-

2.80E+00 pCi/g 6.51E-01 Pb-212 9.18E-01 +-

1.50E-01 pCi/g 9.96E-02 Pb-214 6.61E-01 +-

1.70E-01 pCi/g 1.01E-01 Ra-224 9.58E-01 +-

1.50E-01 pCi/g 1.04E-01 Ra-226 7.52E-01 +-

1.60E-01 pCi/g 1.10E-01 Ra-228 7.01E-01 +-

2.80E-01 pCi/g 2.72E-01 Th-228 9.76E-01 +-

2.70E-01 pCi/g 1.58E-01 Th-232 8.77E-01 +-

4.20E-01 pCi/g 3.25E-01 U-233/234 8.77E-01 +-

2.20E-01 pCi/g 1.66E-01 U-238 6.61E-01 +-

1.70E-01 pCi/g 1.01E-01 1166164 RICHRC5011 15-DEEPSOIL-WEST SIDE PARK LOT MJ7951AF Th-228 1.82E+00 +-

4.20E-01 pCi/g 32%

8.11E-02 6.00E-01 Th-230 9.36E-01 +-

2.60E-01 pCi/g 32%

9.87E-02 6.00E-01 Th-232 1.37E+00 +-

3.40E-01 pCi/g 32%

7.83E-02 6.00E-01 15-DEEPSOIL-WEST SIDE PARK LOT DU MJ7951AH Th-228 1.76E+00 +-

4.10E-01 pCi/g 31%

6.24E-02 6.00E-01 0.2 Th-230 1.18E+00 +-

3.00E-01 pCi/g 31%

8.31E-02 6.00E-01 1.2 Th-232 1.17E+00 +-

3.00E-01 pCi/g 31%

7.32E-02 6.00E-01 0.9 1166169 E901.1 03-SUMP PIT MJ77F1AA Cd-109

-7.20E+02 +-

3.90E+02

< pCi/L 4.72E+02 6.00E+02 Co-57

-6.94E+01 +-

7.30E+01

< pCi/L 1.21E+02 2.00E+02 Cs-137 1.36E+03 +-

1.70E+02 pCi/L 2.42E+01 2.00E+01 Ra-228 3.39E+01 +-

7.60E+01

< pCi/L 1.04E+02 03-SUMP PIT DUP MJ77F1AG Cd-109

-9.55E+01 +-

2.30E+02

< pCi/L 3.85E+02 6.00E+02 2.8 Co-57

-1.25E+02 +-

7.20E+01

< pCi/L 1.11E+02 2.00E+02 1.1 Cs-137 1.24E+03 +-

1.70E+02 pCi/L 2.09E+01 2.00E+01 1.0 Ra-228

-4.48E+00 +-

3.80E+01

< pCi/L 6.57E+01 0.9 7 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 1166176 E901.1 16-SMEAR-WASTE RM MJ7961AA Cd-109

-1.84E+01 +-

1.20E+01

< pCi/sample 1.49E+01 3.00E+01 Co-57 4.48E-01 +-

2.30E+00

< pCi/sample 3.76E+00 1.00E+01 Co-60 4.43E+01 +-

5.90E+00 pCi/sample 9.53E-01 Cs-137 4.09E+02 +-

6.60E+01 pCi/sample 9.57E-01 5.00E+01 Eu-152 1.06E+01 +-

2.40E+00 pCi/sample 2.51E+00 K-40 4.12E+00 +-

1.70E+01

< pCi/sample 8.76E+00 Na-22 3.80E+00 +-

1.20E+00 pCi/sample 9.16E-01 Ra-228 1.49E+00 +-

2.10E+00

< pCi/sample 3.60E+00 17-SMEAR-NaI CAVE/TRAY MJ8AN1AA Cd-109 1.06E+02 +-

4.60E+01 pCi/sample 5.54E+01 3.00E+01 Co-57 2.67E+00 +-

8.00E+00

< pCi/sample 1.34E+01 1.00E+01 Co-60 9.77E+02 +-

1.20E+02 pCi/sample 2.92E+00 Cs-137 4.65E+03 +-

6.90E+02 pCi/sample 3.24E+00 5.00E+01 Eu-152 1.58E+02 +-

2.30E+01 pCi/sample 8.58E+00 Eu-154 1.06E+02 +-

3.00E+01 pCi/sample 2.71E+01 K-40 4.37E+01 +-

3.60E+01 pCi/sample 1.79E+01 Ra-228 3.34E+00 +-

8.20E+00

< pCi/sample 1.29E+01 1171163 E901.1 01-WOOD BACK-UP COOLING TOWER MJ76R1AA Cd-109

-2.45E+00 +-

8.70E-01 pCi/g 1.25E+00 Co-57

-1.88E-01 +-

3.40E-01 pCi/g 5.61E-01 Cs-137

-3.07E-02 +-

8.10E-02 pCi/g 1.37E-01 2.00E-01 Ra-228 6.88E-01 +-

3.20E-01 pCi/g 5.75E-01 01-WOOD BACK-UP COOLINGTOWER DUP MJ76R1AC Cd-109 7.01E-04 +-

8.40E-01 pCi/g 9.39E-01 4.1 Co-57 4.47E-02 +-

2.60E-01 pCi/g 3.77E-01 1.1 Cs-137 4.99E-02 +-

5.80E-02 pCi/g 1.03E-01 2.00E-01 1.6 Ra-228 4.49E-01 +-

2.20E-01 pCi/g 4.15E-01 1.2 02-WOOD FROM RX COVER MJ77E1AA Cd-109

-5.15E+00 +-

1.80E+01 pCi/g 2.13E+01 Co-57

-2.51E+00 +-

3.10E+00 pCi/g 5.21E+00 Cs-137 3.99E+01 +-

6.00E+00 pCi/g 1.34E+00 2.00E-01 K-40 5.01E+01 +-

2.70E+01 pCi/g 1.36E+01 Ra-228 2.42E+00 +-

2.80E+00 pCi/g 4.92E+00 8 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 1187141 E901.1 04-SPENT RESIN-2003 MJ79G2AC Cd-109

-1.88E+02 +-

7.40E+02 pCi/g 1.22E+03 Co-57 9.00E+01 +-

1.80E+02 pCi/g 3.07E+02 Co-60 3.40E+02 +-

5.50E+01 pCi/g 2.17E+01 Cs-137 1.56E+05 +-

2.10E+04 pCi/g 5.98E+01 2.00E-01 Ra-228 7.26E+01 +-

9.70E+01 pCi/g 9.18E+01 04-SPENT RESIN-2003 DUP MJ79G2AF Cd-109 1.24E+03 +-

8.10E+02 pCi/g 1.12E+03 2.6 Co-57 6.54E+01 +-

2.20E+02 pCi/g 3.70E+02 0.2 Co-60 3.18E+02 +-

4.70E+01 pCi/g 1.76E+01 0.6 Cs-137 1.57E+05 +-

2.30E+04 pCi/g 5.33E+01 2.00E-01 0.1 K-40 1.99E+02 +-

2.20E+02 pCi/g 1.47E+02 Ra-228 5.06E+01 +-

3.90E+01 pCi/g 6.74E+01 0.4 1166162 E900.0 04-SPENT RESIN-2003 MJ79G1AD Gross Beta 1.84E+05 +-

2.40E+04 pCi/g 100%

3.26E+01 1.00E+01 1166162 E900.0 04-SPENT RESIN-2003 DUP MJ79G1AE Gross Beta 1.76E+05 +-

2.20E+04 pCi/g 100%

3.20E+01 1.00E+01 0.5 1166163 EPA900.0 11-DEEP SOIL-RX HIGHBAY MJ79P1AA Gross Alpha 4.61E+00 +-

3.20E+00 pCi/g 100%

4.31E+00 1.00E+01 11-DEEP SOIL-RX HIGHBAY DUP MJ79P1AE Gross Alpha 7.12E+00 +-

4.00E+00 pCi/g 100%

4.77E+00 1.00E+01 1.0 12-SURF SOIL-NORTHSIDE MJ79V1AA Gross Alpha 6.77E+00 +-

3.90E+00 pCi/g 100%

4.28E+00 1.00E+01 15-DEEP SOIL-WEST SIDE PARK LOT MJ7951AA Gross Alpha 1.48E+00 +-

1.60E+00 pCi/g 100%

1.87E+00 1.00E+01 1166171 EPA900.0 03-SUMP PIT MJ77F1AE Gross Alpha 7.70E+01 +-

1.70E+01 pCi/L 100%

2.64E+00 3.00E+00 1166173 E900.0 03-SUMP PIT MJ77F1AF Gross Beta 2.34E+03 +-

3.00E+02 pCi/L 100%

5.72E+00 2.00E+02 9 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 1166177 BES9 17-SMEAR-WASTE RM-BLUE CONTAINER MJ8AQ1AA Gross Alpha 2.05E+01 +-

4.70E+00 pCi/sample 100%

2.36E-01 1.00E+01 Gross Beta 4.22E+01 +-

6.70E+00 pCi/sample 100%

6.33E-01 1.50E+01 1171167 EPA900.0 04-SPENT RESIN-2003 MJ79G1AA Gross Alpha 2.68E+01 +-

6.10E+00 pCi/g 100%

1.01E+00 1.00E+01 04-SPENT RESIN-2003 DUP MJ79G1AG Gross Alpha 2.56E+01 +-

5.80E+00 pCi/g 100%

1.16E+00 1.00E+01 0.3 1179060 E900.0 11-DEEP SOIL-RX HIGHBAY MJ79P2AD Gross Beta 2.41E+01 +-

5.20E+00 pCi/g 100%

4.79E+00 1.00E+01 11-DEEP SOIL-RX HIGH BAY DUP MJ79P1AG Gross Beta 2.20E+01 +-

4.80E+00 pCi/g 100%

4.80E+00 1.00E+01 0.6 12-SURF SOIL-NORTH SIDE MJ79V2AD Gross Beta 1.25E+01 +-

3.60E+00 pCi/g 100%

4.80E+00 1.00E+01 15-DEEP SOIL-WEST SIDE PARK LOT MJ7952AG Gross Beta 2.45E+01 +-

5.20E+00 pCi/g 100%

4.81E+00 1.00E+01 1187088 CBTE 04-SPENT RESIN-2003 MJ79G1AH Ra-226 1.13E+00 +-

1.40E+00 pCi/g 88%

2.67E+00 1.00E+00 04-SPENT RESIN-2003 DUP MJ79G1AK Ra-226 5.10E-01 +-

8.10E-01 pCi/g 100%

1.54E+00 1.00E+00 0.8 1187104 CBTE 01-WOOD BACKUP COOLING TOWER MJ76R1AD Ra-226 7.66E-03 +-

7.20E-03 pCi/g 100%

1.23E-02 1.00E+00 02-WOOD FROM RX COVER MJ77E1AC Ra-226

-4.09E-02 +-

1.10E-01 pCi/g 100%

2.56E-01 1.00E+00 1189146 BRTE 16-SMEAR-WASTE RM MJ7961AD Ra-226

-3.64E-03 +-

6.20E-02

< pCi/sample 100%

1.39E-01 1.00E-01 17-SMEAR-NaI CAVE/TRAY MJ8AN1AD Ra-226 0.00E+00 +-

5.80E-02 pCi/sample 100%

1.29E-01 1.00E-01 10 of 11

Sample Results Summary Date:29-Jul-11 TestAmerica TARL Ordered by Method, Batch No., Client Sample ID.

Report No. :47683 SDG No:43282 Client Id Tracer MDC or Batch Work Order Parameter Qual Units Yield MDA CRDL RER2 Result+-Uncertainty ( 2s) 1166174 E906.0 03-SUMP PIT MJ77F1AC H-3 7.01E+03 +-

3.90E+02 pCi/L 100%

3.60E+02 4.00E+02 03-SUMP PIT DUP MJ77F1AK H-3 7.06E+03 +-

3.90E+02 pCi/L 100%

3.58E+02 4.00E+02 0.2 1166175 RL-LSC-008 03-SUMP PIT MJ77F1AD C-14 1.35E+00 +-

6.60E+00 pCi/L 100%

1.33E+01 3.00E+01 No. of Results:

264 11 of 11