Cheryl A. Gayheart Regulatory Affairs Director 3535 Colonnade Parkway Birmingham, AL 35243 205 992 5316 cagayhea@southernco.com February 24, 2022 Docket Nos.

50-348 NL-22-0091 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Farley Nuclear Plant - Units 1 and 2 Correction of Technical Specification Typographical Omission

References:

1. ML19175A243 - Joseph M. Farley Nuclear Plant, Units 1 and 2 -

Issuance of Amendment Nos. 225 and 222 Regarding Implementation of NEI 06-09, Risk-Informed Technical Specifications Initiative 4B, Risk-Managed Technical Specifications (RMTS) Guidelines, Revision 0-A (EPID L-2018-LLA-0210)

2. ML17333A079 - Joseph M. Farley Nuclear Plant, Units 1 and 2 - Reissue of Corrected Technical Specification Page 3.6.6-3.
3. Proposed Guidance for Correction of Technical Specification Typographical Errors, SECY-96-238, November 19, 1996 Ladies and Gentlemen:

This letter requests Nuclear Regulatory Commission (NRC) approval of a correction of a typographical omission in the Farley Nuclear Plant (FNP) Unit 1 and Unit 2 Technical Specifications (TS).

This omission occurred during the processing of License Amendments 225 and 222 for Units 1 and 2 respectively (Reference 1), where Surveillance Requirement (SR) 3.6.6.9 was inadvertently removed. SR 3.6.6.9 had previously been corrected through a reissue of the associated page for License Amendments 212 and 209 for Units 1 and 2 respectively (Reference 2). The omission was neither addressed in the notice to the public nor reviewed by the NRC, and thus falls within the scope of the guidance provided by SECY-96-238 (Reference 3). describes the typographical omission and correction. Enclosure 2 provides the page from Amendments 225 and 222 as issued, with the requested correction noted. contains the corrected page for Amendments 225 and 222.

U. S. Nuclear Regulatory Commission NL-22-0091 Page 2 This letter contains no NRC commitments. If you have any questions, please contact Ryan Joyce at 205.992.6468.

Respectfully submitted, C. A. Gayheart Director, Regulatory Affairs Southern Nuclear Operating Company CAG/was/cg

Enclosures:

1. Description of Technical Specification Typographical Omission 2.

Marked-up Technical Specification Page 3.

Revised Technical Specification Page cc:

Regional Administrator, Region ll NRR Project Manager - Farley Senior Resident Inspector - Farley RTYPE: CFA04.054

Farley Nuclear Plant - Units 1 and 2 Correction of Technical Specification Typographical Omission Description of Technical Specification Typographical Omission to NL-22-0091 Description of Technical Specification Typographical Omission E1-1 1.

Requested Action Consistent with the information contained in SECY-96-238, Southern Nuclear Operating Company (SNC) is requesting correction of a typographical omission that was inadvertently introduced into the Farley Nuclear Plant (FNP) Units 1 and 2 Technical Specifications (TS). The omission was introduced by SNC staff in development of the license amendment request (LAR) submitted to the Nuclear Regulatory Commission (NRC) for FNP License Amendments 225 and 222 for Units 1 and 2 respectively. The page provided did not correctly reflect a TS change previously approved by the NRC with the issuance of License Amendments 212 and 209 for Units 1 and 2 respectively.

2.

Typographical Omission In the SNC application for License Amendments 225 and 222 for Units 1 and 2 respectively, Surveillance Requirement (SR) 3.6.6.9 was inadvertently removed. To be consistent with the approved licensing basis, this SR should be added back into the Technical Specifications as follows:

SR 3.6.6.9 Verify containment spray locations susceptible to gas accumulation are sufficiently filled with water.

In accordance with the Surveillance Frequency Control Program 3.

Correction to Affected Page SECY-96-238 (Reference 3) provides guidance to correct inadvertent typographical errors in the Technical Specifications. The omission described above was neither posted in the public notices nor was it reviewed by NRC as part of the license amendment process. Therefore, it may be corrected without a license amendment.

Farley Nuclear Plant - Units 1 and 2 Correction of Technical Specification Typographical Omission Marked-up Technical Specification Page

Containment Spray and Cooling Systems 3.6.6 Farley Units 1 and 2 3.6.6-4 Amendment No. 225 (Unit 1)

Amendment No. 222 (Unit 2)

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.6.2 Operate each required containment cooling train fan unit for 15 minutes.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.3 Verify each containment cooling train cooling water flow rate is 1600 gpm.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.4 Verify each containment spray pump's developed head at the flow test point is greater than or equal to the required developed head.

In accordance with the INSERVICE TESTING PROGRAM SR 3.6.6.5 Verify each automatic containment spray valve in the flow path that is not locked, sealed, or otherwise secured in position, actuates to the correct position on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.6 Verify each containment spray pump starts automatically on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.7 Verify each containment cooling train starts automatically on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.8 Verify each spray nozzle is unobstructed.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.9 Verify containment spray locations susceptible to gas accumulation are sufficiently filled with water.

In accordance with the Surveillance Frequency Control Program

Farley Nuclear Plant - Units 1 and 2 Correction of Technical Specification Typographical Omission Revised Technical Specification Page

Containment Spray and Cooling Systems 3.6.6 Farley Units 1 and 2 3.6.6-4 Amendment No. 225 (Unit 1)

Amendment No. 222 (Unit 2)

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.6.2 Operate each required containment cooling train fan unit for 15 minutes.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.3 Verify each containment cooling train cooling water flow rate is 1600 gpm.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.4 Verify each containment spray pump's developed head at the flow test point is greater than or equal to the required developed head.

In accordance with the INSERVICE TESTING PROGRAM SR 3.6.6.5 Verify each automatic containment spray valve in the flow path that is not locked, sealed, or otherwise secured in position, actuates to the correct position on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.6 Verify each containment spray pump starts automatically on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.7 Verify each containment cooling train starts automatically on an actual or simulated actuation signal.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.8 Verify each spray nozzle is unobstructed.

In accordance with the Surveillance Frequency Control Program SR 3.6.6.9 Verify containment spray locations susceptible to gas accumulation are sufficiently filled with water.

In accordance with the Surveillance Frequency Control Program