Sk. Southern Nuclear FEB 2 2 2022 Docket No.:

52-025 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel ND-21-0G92 10 CFR 52.99(c)(1)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 ITAAC Closure Notification on Completion of ITAAC 2.3.11.03b [Index Number 4541 Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP)

Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.3.11.03b

[Index Number 454]. This ITAAC confirms that a simulated high radiation signal causes the discharge control isolation valve WGS-PL-V051 to close. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which is endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully stjbmwtea Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4

Enclosure:

MJY/DCH/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.3.11.03b [Index Number 454]

U.S. Nuclear Regulatory Commission ND-21-0092 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena III Mr. D. L. McKinney Mr. H. Nieh Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. J.B. Williams Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Ms. J.M. Coleman Mr. C. T. Defnall Mr. C. E. Morrow Mr. K. J. Drudy Mr. J. M. Fisher Mr. R. L. Belike Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE; VND.LI.L06 File AR.01.02.06 Nuclear Reoulatorv Commission Ms. M. Bailey M

M Ms. A. Veil M

M M

M Ms. N. C. Coovert M

M M

M M

M M

M M

M M

M M

M M. King G. Bowman C. P. Patel G. J. Khourl C. J. Even B. J. Kemker C. Welch J. Gaslevic O. Lopez-Santiago G. Armstrong M. Webb T. Fredette C. Santos B. Davis J. Vasquez J. Eargle T. Fanelli Ms. K. McCurry

. J. Parent

. B. Griman

. V. Hall

U.S. Nuclear Regulatory Commission ND-21-0092 Page 3 of 3 Oqlethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. 8. M. Jackson Dalton Utilities Mr. T. Bundros Westinahouse Electric Company. LLC Dr. L. Oriani Mr. D. 0. Durham Mr. M. M. CorlettI Mr. Z. 8. Harper Mr. J. L. Coward Other Mr. 8. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. 8. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-21-0092 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-21-0092 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.3.11.03b [Index Number 454]

U.S. Nuclear Regulatory Commission ND-21-0092 Enclosure Page 2 of 3 ITAAC Statement Design Commitment 3.b) The WGS provides the nonsafety-related function of controlling the releases of radioactive materials in gaseous effluents.

I nspections/Tests/Anal vses Tests will be performed to confirm that the presence of a simulated high radiation signal from the discharge radiation monitor, WGS-017, causes the discharge control isolation valve WGS-PL-V051 to close.

Acceptance Criteria A simulated high radiation signal causes the discharge control isolation valve WGS-PL-V051 to close.

ITAAC Determination Basis Testing was performed to confirm the Gaseous Radwaste System (WGS) provides the nonsafety-related function of controlling the release of radioactive materials in gaseous effluents by verifying a simulated high radiation signal caused the discharge control isolation valve WGS-PL-V051 to close.

Testing was performed in accordance with the Unit 3 component test package documented in Reference 1 which verified WGS-PL-V051 was initially open. The test simulated a high radiation signal on the discharge radiation monitor and WGS-PL-V051 was verified to close on the Plant Control System (PLS) monitor in the Main Control Room and verification was documented in the component test package.

This testing verifies that a simulated high radiation signal causes the discharge control isolation valve WGS-PL-V051 to close.

Reference 1 is available for NRC inspection as part of Unit 3 ITAAC Completion Package (Reference 2).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there were no relevant ITAAC findings associated with this ITAAC.

ITAAC Compietlon Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.3.11.03b was performed for VEGP Unit 3 and that the prescribed acceptance criteria were met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

U.S. Nuclear Regulatory Commission ND-21-0092 Enclosure Page 3 of 3 References (available for NRG inspection)

1. SV3-WGS-ITR-800454, Rev. 0, "Unit 3 Test Results for High Radiation Signal Causes WGS-PL-V051 to Close Testing: ITAAC 2.3.11.03b"
2. 2.3.11.03b-U3-CP-Rev0, ITAAC Completion Package