Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Prakash Narayanan Chief Technical Officer TN Americas LLC 7135 Minstrel Way, Suite 300 Columbia, MD 21045

SUBJECT:

TN AMERICAS LLC APPLICATION FOR CERTIFICATE OF COMPLIANCE NO.

1042, AMENDMENT NO. 3, TO NUHOMS EOS SYSTEM (DOCKET NO. 72-1042, CAC NO. 001028, EPID: L-2021-LLA-0055) - REQUEST FOR ADDITIONAL INFORMATION (NEW SCOPE ADDITION)

Dear Mr. Narayanan:

By letter dated March 31, 2021, as supplemented June 23, 2021, August 4, 2021, September 3, 2021, October 22, 2021, and November 30, 2021, TN Americas LLC (TN) submitted to the U.S.

Nuclear Regulatory Commission (NRC) an application for Certificate of Compliance No. 1042, Amendment No. 3, to the NUHOMS EOS System, pursuant to the requirements of Part 72 of Title 10 of the Code of Federal Regulations.

The staff has determined that further information is needed on the new scope addition (submitted October 22, 2021), to complete its technical review. Note that the new scope addition has added 3 months to the original schedule to complete the review for this amendment. The request for additional information (RAI) is attached. Your response should be provided within 30 days of the date of this letter. If you are unable to meet this deadline, please notify us in writing, at least one week in advance, of your new submittal date and the reasons for the delay. The NRC staff will then assess the impact on the revised schedule (due to the new scope addition) to complete the preliminary safety evaluation report by July 2022 and notify you if the schedule needs to be revised again. The estimated effective date for this amendment is now January 2023.

January 24, 2022

P. Narayanan Please reference Docket No. 72-1042, CAC No. 001028 and EPID: L-2021-LLA-0055 in future correspondence related to the acceptance review for this licensing action. If you have any questions, please contact me at (301) 415-6825.

Sincerely, Christian Jacobs, Senior Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1042 CAC No.: 001028 EPID: L-2021-LLA-0055

Enclosure:

RAI for New Scope Addition Signed by Jacobs, Christian on 01/24/22

ML22020A390(pkg), ML22020A391(ltr),

ML22020A392 (Enclosure)

OFFICE DFM DFM DFM DFM NAME JIreland DDunn ELove WWheatley DATE 01/21/2022 01/21/2022 01/21/2022 01/21/2022 OFFICE DFM DFM DFM NAME HGonzalez YDiazSanabria CJacobs DATE 01/24/2022 01/24/2022 01/24/2022