6 to Updated Final Safety Analysis Report, Chapter 7, Figure 7.3-7, Sheet 2 of 2, Drawing 102792, Revision 5, Sheet 1, Electrical Logic Diagram Component Cooling Water Pumps
ML21305A621
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A621 (1)


Text

2 3 4 5 6 7 8 9 10 NOTES CS/CLOSE (SWGR) 43/TS - TRANSFER SWITCH TRANSFERS CONTROL FROM ACS/START MAIN CONTROL BOARD TO HOT SHUTDOWN PANEL BREAKER IN A43/MAN TEST POSITION <LOCATED AT SWITCHGEAR).

E 43 - MODE SELECTOR SWITCH FOR SELECTING REF 5, D TRANSFER TO DIESEL II AUTO" OR MANUAL MODE ( LOCATED AT II II 6 & 7 BLOCK AUTO START HOT SHUTDOWN PANEL & MAIN CONTROL ROOM).

HOR A 6 - REMOTE CONTROL SWITCH LOCATED AT HOT COMP COOL WTR LOW PRESS SHUTDOWN PANEL.

HOR B SIS A - REMOTE CONTROL SWITCH LOCATED IN MAIN CONTROL ROOM.

LOW PRESSURE SETPOINT ONLY REACHED LUBE OIL PRESS WITH LOSS OF ALL RUNNING PUMPS.

REF 5, A >-S_I_S_A_U_TO_ _ _ _.,..

6 &7 START SIGNAL 0

a REF 5, B 4KV AUTO TRANSFER CLOSE D 6 &7 SIGNAL (NO SISl 6CS/START 52HFl2 NO. 21 52 -- 52HGl2 NO. 22 43/TS/CONTROL ROOM b 52HHl2 NO. 23 TRIP ALARM 6CS/NEUT REFERENCES DWG NO.

I. LOGIC DIAG SYMBOLS _________ 19425 414f-----------'

'-----t----+-------.1--....:...J 2. SCHEMATIC DIAG COMP CLG WTR _____ 44131 I 643/AUTO 3. SLM&R DIAG 4KV BUS F ________ 44 I 229 ALARM 4. SLM&R DIAG 4KV BUS G & H ______ 44 I 230 C 5. LOGIC DIAG 4KV BUS F AUTO TRANSFER __ 441286

6. LOGIC DIAG 4KV BUS G AUTO TRANSFER __ 441297 6CS/S TOP 212 t - - - - - - - - - - - - ~ 7. LOGIC DIAG 4KV BUSH AUTO TRANSFER __ 441337 OVERCURRENT REF 5, F >-S_I_S_A_U_TO_ _ _ __

6 &7 START SIGNAL REF 5, G 4KV AUTO TRANSFER A43/MAN 3;3 f - - - - - - - - - - - - - - - - - - . i /

6 &7 SIGNAL (NO S!Sl REF 5, c TRANSFER TO DIESEL ACS/STOP 6 &7 LOAD SHED CX) START C.C.W. PP CS/TRIP CSWGRl CS/ON 0

N C.C.W. PP RUNNING CS/AUTO NO. 21 52-2F-44

~ B L.O. LOW PRESS NO. 22 52-2G-41 (3 MIN) 2;2 ,_______ ___, NO. 23 52-2H-35 u

0 C

Q) 0 C W

0 Q)+-

I 00 Q)

COMPONENT COOLING PUMP AUXILIARY LUBE OIL PUMP OVERCURRENT 1--------l~....!:::...J ON OFF  :--0 NUCLEAR SAFETY RELATED 1 u o KEY DWG. SECTION 3

- .o UNIT 2 lo NI s::;r en - Vl DATE REVISION DESCRIPTION ELECTRICAL DWG SCALE:

r-- I z 06-18-2018 Revised Pe, DDN-2*1867 BI LL OF MAT L:

NNN Oo, LOGIC DIAGRAM

- r--

oo L A D. D. ZNS4 COMPONENT COOLING WATER PUMPS SUPSDS:

II N Q)

SUPSD BY:

0:::: 0 U) R. E. FXC2 w- =:J DIABLO CANYON POWER PLANT DRAWING SHEET PAGE REV I- II I. V. NIA VlZO PACIFIC GAS AND ELECTRIC COMPANY 102792 0 5

<( C) <(

o::::ou P. E. NIA SAN FRANCISCO, CALIFORNIA INPG I Size