7 to Updated Final Safety Analysis Report, Chapter 9, Figure 9.4-8, Drawing 516103, Revision 16, Mechanical Ventilation Flow Diagrams, Sheet 1
ML23241A752
Person / Time
Site: Diablo Canyon  
Issue date: 05/25/2023
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23241A052 List: ... further results
References
DCL-23-044 516103, Rev 16
Download: ML23241A752 (1)


Text

TURBINE BLDG TURBINE BLDG ELEV I0~* - 0"

/

FJRE0AMP[R(F0)

I~

BACK0RUT 0AMPER (800)

D INH~£1Ex11Aus1 PLrnu11 (Qll SuPPLYIEXHAUSlfAN

=°7's;----- --~*-Uc,X ="'.=iv1R~:REA

  • l~:E:~E~f j

C(lllNG/WALLRECISTER SUPPLY DUCT RHIF RMIG ct MOTORIZED CONTROL DAMPER E

FILTER BOX !FBI FLOW DIAGRAM FOR INVERTER ROOMS g. <180V SWITCHGEAR ROOMS IN AUXILIARY BLOG !UNIT I)

(SCHEMATIC0NLYI

/

FlflE DAMPER <FD>

!~

BAC~0RAFT 0A/of>ER <BODI D

1NTHE/XHAUST PLENUM (Qll SUPPLY/EXHAUST FAN

--~AU=XrB=~~iR2~:REA *tN;i~;F j

C[JL1NC/WALL R[CJSTER EXHAUST0UCT 2F0-6 ct MCHORIZE0 CONTROL DAMPER I ~

E FLOW DIAGRAM FOR INVERTER ROOMS g. <180V SWITCHGEAR ROOMS IN AUXILIARY BLOG (UNIT 2J tSCHEMATJCONLYJ me JCN VALUES SSUPPL IEO INC ROOM ACTUAL LANCE REPORT, i!i 6 f--r-'"'=-~"='-e',-

",-'°-'-'"--iy3C7F~

CABLE SPREA0lHC ROOM FLOW DIAGRAM FDR CABLE SPREADING ROOM ( UNIT I) r-+-~,O~-,~,o~*,..,~- SJ'-OO-OT"-"-,J'-,3CTFOMO t ~

~. z~-~;;.

CABL[SPREA0IHCROOM FLOW DI AGRAM FOR CABLE SPREAD l NG ROOM (UN! T 2 l TOE-27 FOR REF.

ONLY; SEE 0~ ~21644 M0-2so Mo-zsr l 110-2a2 NOTE l :CABLESPREA0INCROOMISN0Ri'IALLYAIR CONDI TI ONED BY CLA SS II UNIT AC-170.

11HENAC

  • l701S N0T

!N OPERAT!ON, Z700 CFM FROM CLASS I SYSTEM IS 0ISTRIBUTEOPROPORTIDNALLYTHROUCH 90UTL ETS.

fO f!RE0AlfER

),(l HANUAL0ANPER SO SMO~E OAMf'ER

  • OAMPERPOS!TlONTAEILE 2AC* l70 2f1l-J36 2H0*l37 2MO*J38 CABLESPR[A0INGROOM!SNORM.ALLYAIR COJ'I0ITIONEOEIYCLASSl ) UNIT2AC - 170.

\/HEN 2lC* l 70 lS NOT IN OPERATION,

21()0 CFM FROM CLASS I SYSTEM JS 0ISTR!EIUTEO PROPORTIONALLY THROUCH

90UTLETS, F0 FJREOA'4"ER MO MlHUlL0A'4"[R SO SMOl(E0lMl'ER

,_,,_,.t ___ [~~~--------:J-----co, s.mM

'-Ell 1

'-nl I 1-SO-lS

__ _! l*SO-JT

___ J

'-ca

'-nL EXHAUST SUPPLY FIRE g. SMOKE DAt-f>ER COMROLS (UNIT I I NOTES:

I. FORLOCATION0F0AHPERS, SEE0\11,5937.

2. FOR ELECTRICAL SCHEMATIC 0IACRAM ANO LOCATION 0RA\IINCS, S(( OWG JJe2n lN0 57612.

OPERAT I ON PROCEDURES:

I.AS]Cf(ALFROMTHECO,SYST[HWlLLCLOSETHEFIRE 0Afof>ERS AHO S~~E OAfof>ERS IN HIE SUPPlY ANO OHAUST DUCT. NOAlR \/I LL BESUPPLl[0/EXHAUSTEO INTOIFRONTHECAEILESPRO0JNCROOl'I.

z. ~~p;;.!~~AIT/HE F)RE AHO SMOl(E 0AJof'ERS NI LL BE 1 - --------------T-----co,
~:

--~ ZfO 36

_ __ J

'-nL I En l

___ i 2S0-37

'-rrL

'-nL EXHAUST SUPPLY FIRE g. SMOKE DAt-f>ER CONTROLS (UNIT 2>

NOTES:

I. FORLOCUIOl-!Of 0AJof'ERS, SEE DWG593 7.

Z. FOA[LECTR I CALSCH[MATICO!AC!IAMlHOLOCATIONDRA NJ J,ICS, SH owe ))8213 lNO 57&12.

OPERATION PROCEDURES:

I. A SIGNAL FROM THE CO, STSTEM\lllL CLOSE THE FIRE 0l..,.ERSlNOSHC>f:[0lHPERSJNTNESUPPLTlHO EXMAUSTOUCT. NOAIRWILLBESUl'f'LIE0/EXHAUSTE0 lNT0/FROHlHE CABLE SPRElOINGROOM.

2. R[SETTIJ,IC OF HIE FIR£ AHO SMOKE 0lHPERS WILL BE OONEHANUALLY,

UN IT I & 2 SYSTEM 0

16