OIESELGENERATORN0.2I 3250KVA2600KWO.BPF Qi!I_
DIESEL GEN 59
~~[)~51 ~g~
HHG I OIESELGENERATORN0.22 3250KVA,2600KWO.BPF
!SEENOTE2l SHGIO filfilJ MCCTRANSFN0.2G 4I~0t:.-4BOY/2HV I000/1333KVA DG 2 I & 22 NUCLEAR SAFETY RELATED SYNSW 52HHll DEVICENUlflERS TABLE OF DEVICES DESCRIPTION Al+1ETER,CELL GI I AMMETER,CELLH9,ll,12,15.G6,7,8,12 M+1ETER,CELL HS Al+1ETER,CELLG9 Al+1ETER,CELLHIO,GIO AMMETER,CELLH7,13,14.G5,13,14 Ar+1ETER,CELL GIi AMMETER,CELLH9,ll,12,15.G6,7,B,12 Al+1ETER,CELLHB Al+1ETER,CELLG9 Ar+1ETER,CELLHIO,GIO M+1ETER,CELL HT.G5 FREaUENCYTRANSDUCER RECORDER FREQUENCY RATING MFR TYPE 0-SOA G.E.CO AB40 O-75A G.E.CO AB4O 0-ISOA G.E.CO AB40 G.E.CO AB40 0-SOA 11.E.
0-75A
\I.E.
HSOA O-30OA 55-65Hz ESTERLINEANGUS 55-65Hz YOKOG.lw.l REMARKS 2918461A26 AT CONTROL BOARD M00'6284B AT CONTROL BOARD DXl004N AT CONTROL BOARD DXI004N AT CONTROL BOARD RV RECORDER VOLTS YOKOG.lw,\
YOKOG.ll/A OXI004N AT CONTROL BOARD RVAR RECORDER VAR OJI004N AT CONTROL BOARD ATSIOIRH!EASTSl Elollll SYN SYIDIIOSOOPE 60Hz
!I.E.
KI241 I86l2l5AOI AT CONTROL BOARD VOLTMETER SYNCH 0-ISOV il.E.
KA241 29IB460Al2 AT CONTROL BOARD 50I2002IPZUL2 ATSIOIRH!EASTSl Elollll 0-ISOV
- NOLLER, 00012HORVTIIOl2 I ELEMENTl0 120v, 30 ~lTf~lf51c 0001S'JOOJLJIm2 2 ELEMENT30 120V, 5A OR JEMTEC 000l5!1J1ll.1'1lll512 2 ELEMENT 30 0-2.0MW W.E.
KP241 2 ELEMENT, 3~, 3 WIRE VARMETERM.C.C.TRANSFORMERS VAR VARMETERDIESELGEN SYNSV 1
52HHl4:
' :R l
BUS I ___ INC 1:
-"'>J LEGEND 4lHHIO/TS 4lHHII/TS
~
AMMETER SWITCH fill VOLTMETER SWITCH
~
TEST SWITCH, T-POLE
- LAMP, INDICATING, WHITE PHS PHASE SHIFTING TRANSFORMER CT8EJ CONTROL STATION AT LOC ~
[Bf[]
RESISTIVE TEMP DEVICE co, EXCITER GOVERNOR ISOLATION SW AT SWITCHGEAR IDISCBKRCONTROLFROMCONTRM)
MANUAL TRANSFER SW DIGITAL REFERENCE UNIT ATLDCSED21A MAGNETIC PICKUP UNIT UVRELAYmBUSGIHl2NOLEVELI CONTROL TRANSFER SW EOU I PMENT LO CAT I ON CB CONTROLBOIIRD,CONOENSIITE&FEEDWATER CIJH CONTROLBOIIRO, ENG.SAFEGUAR04KVBUSH i:NCS CONTROLBOIIRD.CONTAINMENTSPRAY
~ CONTROLBOIIRD, COMPONENT COOLING CNV CONTROLBO..,RO,CHEM&VOLCONTROL i:NAS CONTROL BOARD. AUX SALTWATER CNSJ CONTROLBOARD,SAFETYINJ&ACCDISCHARGE
~ CONTROLBOARD,RESIOUALHEAT RHH RELAYBD.ENGSAFEGLIAR04KVBLISH SHH7 4 I60V SWGR BUS SECT H. CUBICLE NO. 7 CCD21 DIESEL CENERATOR NO. 21 MAIN LEAD TERH BOX SED2I GG021 OIESELGENNO. 21GAUGEPANEL SHGSI SWGR4KVBUSGSYNPNL I SHGl3PTSWGR4KVBUSGCUB13POTTRANSF REFERENCES SEE REF. 9 SEE REF.
10 SEE REF. II SEE REF. 9 I. DESCRIPTION OF ELECT SCHEH DUG SYMBOLS I EQUIP LOC
________ 050003
- 2. SINGLE LINE METER I RELAY DIAG 4I60V Slrl!lR BUS SECTION "D" I "E" ___ 441226 J. SINGLE LINE METER I RELAY DIAG 4I60V Slrl!lR BUS SECTION "F" ______ 441229
- 4. SCHEMATIC DIAGRAM 4I60V BUS G AUTOMATIC TRANSFER __________ 441353
- 5. SCHEMATIC DIAGRAM 4I60V BUSH AUTOMATIC TRANSFER __________ 441354
~: ~~~~ L~~~EMDIAG4KVDIESELGENERATORS;;ASSC!RcU1TBRKR-::.-:::,-:::,-:::,-:::,-:::, ~:~~;~-1
- 8. ELECT SCHEM DIAG AUX SALTIIATER PUMPS ________________ 441287
- 9. ELECT SCHEM DIAG RESIDUAL HEAT REMOVAL PUN'S ____________ 441309-1
- 10. ELECT SCHEM DIAG CHARGING PUN'S NO. 21 I 22 ____________ 441312-1 II. ELECT SCHEM DIAG MOTOR CONTROL CENTER TRNSFl-ll ___________ 441364-1
- 12. ELECT SCHEM DIAG COMPONENT COOLING WATER PUN'S ___________ 441311-1
- 13. ELECT SCHEM JAG AUX FEEDWATER PUMP ________________ 441302-1 14.ELECTSCHEM IAGCHARGINGPUK'N0.23 40075-
- 15. VENDOR DRAWINGS DEG GOVERNOR CONTROL SCHEMI.TIC ___________ 663082-407,408 NOTES I. FORELECTRICALDEVICESTECHDATAANDSETPOINTSSEESAPFLOCDATABASE.
- 2. ~~:~~Lt~7~~5~E~0~E~r~rnov~~U~~'.S DRAWING, REFER TO CALC 015-0C KEY DWG. SECTION_I_C_
Q3u ~OU~TED=O~~
UNIT 2 34