6 to Updated Final Safety Analysis Report, Figure 7.3-46, Sheet 1 of 2, Drawing 437684, Revision 16, Sheet 1, Electrical Schematic Diagram Liquid Radwaste Solenoid Valves
ML21305A135
Person / Time
Site: Diablo Canyon  
(DPR-080, DPR-082)
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A135 (1)


Text

01 n4 CUTLl~C E

r oLD D

C r nLD B

OLD~

o A

N en N

ro 0

.Q)

C

+-

0>

CJ D

0

  • C

,q-- 01 =:,

m uo::

<D

  • z

,-.. ST :,:

r0co *

  • q-u) '.._

II t'-

Q) 0:"' "'

w sr o I-IJ) ZO

-0: Cl <(

o:ou I v89L£\\7 2

COI..JTAINMENT

!SOL. PH A I REACTOR COOLANT DRAIN pp!; DISCHARGE TRAIN A OPEN FCV253 5A C:ijV RAR p~~1-0-:--~1 E.3A INDICATION SEE NOTE I (TYP FOR 4) 125V DC CKT 1520 r

3 4

5

~

RCDT VENT HEADER RCDT TO GAS ANALYZ.ER OPEN FCV 255

~

INDICATION OPEN FCV 258 I

INDICATION CONTAIMENT BLDG SUMP PPS DISCH, I OPEN FCV 500 I INDICATION I

tRNS$A I

1(6:4

~~B=~

..1.. 3RIA

,- ~

RN~$A T

RAR p

REF. OWG. 437546 FUl 3* 0 I J v,O:::.....I

'~~ g~

E2A El-I lcli:'.; Cil~

l

{,BT626[

P©CVle Pl cio ~ "'

x_CNV El-I
ll:'.?;J

'.l'B fP$LRII ll A B 1r}J~~~~~~ A P(!)LRll 1

D 0-d~

Z LO r---

1-"'

5"1' u

0:: '-"

G 3:

C, u

0 u..,

iDI~

~-

J Jts/RESET 1--- --,

)'. C A J' FCV253 FCY253 1 yCNY CN~y CS/ijflJTRAlIA CS/RESET-,-B E4A E5A RESET

_iHAR tRAR 3RIIIXI I

3RIA t

yrl)JLRII r, ~R_Jf\\l

~1!1,1

~gTI

- I j 11:

3RIAXI

-1--; §-

'::i li E~l-~TGZbE

~

,: ~TI I

J BTX21i>E g-;

~ ;J, I ~H-1 --

LL~{sIJ RAR~

PICK*UP 1 COIL --1 (TYP)

~LRII,

\\ ~ _ iTJ iPMl22 THOW!N(i COIL (TYf.)

SV512 FCV253 PMIZ7 NI-I NH P/14122 t--Nl-l--o-pq!LRfl FCV255 __,_A S/NfUI~

RESE:1 3RIA)(2 NH PM69 NI BT)(Zf>f.ir-NH P~CVI n

FU I 3-0, BT62f.E N

FCV255..1.

CS/REScT-,---B P(pLRII

  • 7 E./-12
~BTG26E I ~BTX26E IE1-12~-

- _J iPUIZ7 SVSl.4 F0255 FCV258_._

llEUTRAlfA RESET,l 3RIAX3 FCV258..1.

CS/RESEJ-,- El r-2RIAX3

? PIPLR[I I

,;m

~ :-1 E.1*13 I

Re ~~;*+

I ~BJXZbE I

~ @1 I BTG2~E

"' I o:TI ttl I E!-13 I

I

-~J ?PMl27 SV517 FCV258 FCVS00..1.B CS/RESET-,-

FCV500__._

r/MEUTRALTA RE5ET l 3RrAX4 f 3ffiAX4

? PruLRII

--7EH4

~l I ~BTG2f.E it!TI

- ~

.J:

BTX20E T

J El-14 L -

_'._j t PMtl,9 SV518 FC.V500 N~

SA IC.NV NI-I AUX CONT ROL BOARD VA LVE POS I TION INDICATORS !NO TE 2 1 I-RE ACTOR COOLANT DRAIN PPS DI SCHARGEt RCDT VENT HEADER t

RCDT TO GAS ANALYZE~

FC'/253 CLOSEJ I

FCV253 OPEM

°C V255 CLOSED I

FC'/255 OP EN FCV258 CLOSED I

F C'258 OPEM MATCH 1

~

1 POBI r

-,- - I CI RCLE la~

Pl-----01 r ___ _ L

___ _ r ___ J I ___ J

-Poe to 1 - :

SIO/C5

'<=7 POLRI I MATCH~

CIRCLE(~

CONTAINMENT r---- -----

, POBl - 101 1

S I 0 /C I

, dPOS253 - I G 1 L-- --

____ I POBI 3G I POL~ I I ~

3R I /1:< I,I" 1 POBl -1 0 I

. S 0/CO 1

,aPOS253 - R'

~l -

1 P05 I - I O I 1 POB I - I O I

$1 O/C3 1

S I O/C2

, dP0S255 - I G :

dFC V255 - I R:
  • ,:,r *:::r-3R I 3G2 3R2

'"'"" i POLR 11 )

socs,' i 3RJ.~X 2 i~

3RIA XI 3RIAX2 -

r"J 3G3 POLR I I

)

3RI AX 3 ;~

- POB 11-i O I - :

SIO/C4

'. dPOS2f 8 - IR_:

POB I y 3f; 3

=i 3RI AX 3 l I

LIQl!JID RADWA5TE ISOLATION VALVES-CIRCUIT NO I0512SVOI CIRCUITS LISTED ON DWG. 103072 f

CON TA I NMrnT BLDG SUMP PP S DI SC " -

_____F_I.11500 CLOSED I

FCl/500 OPEN r ___ J ____ _

1 PC3 I-IO SIO/C 7 1

1dPOSS OC - 1G :

~ l --

r ____ l_ ___ _

1 POB I - IO I SI 0/C6 1

, dPOSS00 - I ~ :

  • -r 3G4 3~'4

"'" i 3RIA X4 -~

'°'"" i 3RJ!, X4 i

150L. PH A

s REACTOR COOLANT DRAIN PPS DISCHARGE I

RCDT VENT HEADER RCDT TO GAS ANALYZER i

TRAIN B OPEN fC.Y 254 I

INDICATION I

OPEN FGV 250" I

INDICATION OPEN FCV 257 I

1-I -

I I

I I 25V DC CKT.

152D p

REF. OlvG. 4~75%

FU4*0I

~l-,,,

P0GI

~ I -2 K'I~

EH I

P0LRl2

,..,_ c:i,-

~ E1*2 6

INDICATIOIJ 7

~

8

~

CONTAtH P051TION REMA.RKS REMARKS ClCSE NE1JT:RESE1

-II-A X

X WI$ DWq TfllS DWG

-II-B X

11115 DW/ii THIS DWG.

-II-C X

X SPARE.

SPRING RElURN -II-D

)(

SPARE m tlEUTRAL LIQUID R,IDWASTE.

LIQUID RADWASTE.

COi-iT. SWITCH l~LATIOt-1 VALVE TRAIii A l'SOLATIOII VALVE Ti?AIN B C5 1

9 10 TABLE OF DEVICES DEVICE NO.

fUNC.f\\01\\1 l'-ATING I MFR. I TYPE jCAT./DI\\IG.00 REMAf'-Ko

{_7)(8) 03)

K<'ol4-CONTAINMENi ISOLl>.TION K<'ol~

PHA~E A AUX, RELAY I

I I

5V512 SOLEr,.JOID VALi/ES 1

1 1

12.5 VDC 513,5 14, 515.511 1 fCV253 FCY254 fCV2!:>5 FCV2Sb FCVf57 FCV25B FCY2b0 FCVSOO FCV501 cs ' cs ' cs ' cs ' cs ' cs ' cs ' cs ' cs USED AT LOCATIONS Cf..lV, PmLRII, Pd)LRI2 518, 51~,

532,53.3, 197 t

I I

I I

R3 GAS AtJAl'(lER ALJX.COtJT R~LAYI -=----_ I -

[ (.1 0 )

R3X GAS ANAL HER AUX. RL'l'.

I

C-H-T --M -* IP2bMRD42AI SAMPLE POIIJT '1° 3 FU I -0 I r OPEN T

p....-u::::::n POCV I -1 0 :

S]/C7 1

cFCV6 I 8-ICS :

-EID!r __ _

I BTGIIE b BUIIE~

I X'3V197 SVl97 FCV618

~

BTGIIE NI 6 N ~

N 1-~~jlE X5VI 97 FUl - 02

, --- ~ ---

I 1 P,JC Vl - 10 1

S6/(4 1

cFCV6 18-IG :

-~r---

36 BTGIIE~

BHIIE~

3G I

XP~S50

~IA Ol}'F(Vf,18 11/DICATIONI POCVl-10 :

S6/C5 1

cFCl/6I8-IR :

p-~~;, r ---

3R BTGIIE 6 BTXIIE. ~

3R XP~S50t P'55o1B

~

FCV618 RCDT DRAIN-CIRCUIT NO. IOl975VOI CIRCUITS LISTEJ) ON DW&. 103072 VALVE POSITION REMARKS CONTACTS ~

FCVS254.= (OLV>""-1,<>!

CL OSE OPEN 257.501 ll-2" 2.58&500 FCV6/8 C

A X

1 ~~iciE~~~ 1T~1 SPARE HM[ (G I B

X

.-,,..;,RE I

.SPARE C

C X

SPARE I

D X

IS PARE I

I VALVE OPEN ~ITION SWITCH VALVE POSITION REMARKS CONTACTS CLOSE OPEN 1CV$e54,,l5',me53, FCv,1a j 2.57, o0(£,ci Ll2.58i-SOO C

A X

SPARE SFARE SPARE B

X

=!ED L -

SPARE HMI Ii I ANn HMl1.RJ C

C X

SPAR/;

I SPl\\f?E SPARE D

X 1,/~H /WEI LT 5P'AR'E-t VALVE CLOSE POSITION SWITCH I:;. -.5WI TCH.5 FCV 2.53, 2~,/ 500 A&AI..I IJOJ../ f/J l'LAff.

JMTCH FO.{' FCV :2.5.5 REnOVcLJ.

CONTAINMENT BLDG. SUIIIP PPS Vl':>CH.

OPEN FCV 501 I

INDICATION I

HV _ __ FLOW COl<JTROL VALVE SEE DWG FOR NQS POCV I - IO :- AD\\ cONTROL '"Eu PLC pos __ _ 1 'IALVE POSITI ON 51'/ITt~

~ D~TE

,3RJBXl,-5 3*SV513,515, IYAM CONTROL AUt!LIARY lmAr 53'1.Sl'l,5~

1'05/T/01./5 l('f:l,\\Al',l<.S (OIJTACT5 Ct0J OP~/.14 ~22',2es, II.ITEF11. 2!;,1,tlJOO

-n-- A X

.5/'AEe

--n-t, X

.51'AR£

--H-C X

JP,4Rc

--n-- D X

MONllOR L I

< REF. 9 l VALVO: CLQJe f'OSIT/ 0/.I.5/./I TCH P0S/187 A, POS //93A,P05!202A { POS/205A EQUIPMEN T LOCATION NUMBEP..S tONTRDl BOARD CHEMICAL 5' VOLUME CONTROL MOUNTED IM POB I MOLJNlEC IN POCV I SEE DWG FOR

~

CNV pgi CV I tONTRDL PAt-iEL JMIT t CHEMICAL VOLVIAE (AUX. BLOG. CONT. 130.)

l\\tJ,~A RA~K NUUE.AR. 51>.FEGUARO OUTPVT A,

~90 INSTRUlll'.Et-lT P0$ li'l0 (L()CAL MOV"-ITEO)

XS\\/ 197 lhl5TR.UMOJ1 SV 197 lLOtAL MOU"1TE0) _

i!>TC.ffiE TER/v\\lN1'L BO)( G 2.G"E.

PM184 MECHANICAL PANEL - NO. 184 REACTOR COOLANT DRAIN TERMINAL 60.X AREA H.'I"-

/fO CONTROL PANE.L UNIT I GAS ANALYZER AUXILIARY RELAY RACK 8THil0 P¢GI RAR P(QLRll P(!)LRI2 LIQUID RADWASTE ISOLATION VALVE WNTROL PANEL NO.

II

" 2 REFERENCE ORA.WIN GS

1. DE5CRI PTION OF ELECT.StHEMATiC DIM.~ CKT. D£5\\~NATIONS -

DWG.lf 050003

2. EQ.UIPMENT LOC.ATIOM NUMBER$ -- -- -- -- -- --

IIW{,, /I 101900

3. Plf'ltJC.

SCHEMAT\\t -- llQ.UIO RADWASTE 5'($lEI,\\-- ---

- - -- DWG.. #

10'1-0 l'l 4, 1"'5TRUMENT SC.HEM"TIC -

FLOW !tJSTRUMEIJi" WSTEM

--- owe.. ii 1oio ;?

5. $INC. Lt LIN~ METER J, Ro LA'( -

1'1-'5 V Ot SYSTEM -

-- DWC.,,tl437541o;44507!5 G.

CIRCUIT SCHEDULE NUCLEAR CONTROL __ __

DJIVG. It 103072

7. @ FUNCr iON OIAc, RAl--'5 -

~ -

RiaC."

o '7 3/~~

8. @ =:,OLID 5:A:'£ f'POTe'.(., 1,?t, $-r'5,Et,! -

RE'C...

Go.32.31

~ -

.S CHE.MATIC DIAGRAM MONITOR L IGHT AUX ~E:LAYS -

DWG- /f" 445287 10, SCHE:111ATIC OIAGRA~ c:;A<:, AIJALY:i!l:R. -

OWG, "' 43764 7 II.

ARl?G'T. & DIA.G. OF CONN., LIQUID RADWASTE ISOL. VL'I. CONT. PWL I. DWG_ if 4475.ll].

12.

2. OWG ;r 447543

13. SC HEM DIAG. SSPS OUTPUT RELAYS, TRAIN A, TRAIN B _

_ DWG* 501869, 503088

14. 4U X CONTROL 80 SYS FUNCT I ONAL REQUIREMENTS SPEC _______________ OWG. 663 195 -33 NOTE :

LIGHT INDICATES CONTROL STATUS RATHE.R THAN VALVE POSITION.

2. HM:

INDICAT I ON INDICATES CONTROL STATUS RA THER THAN VALVE POS I TION.

RCDT N2 SUPPLY OPEhl FCV ZwO I

INDICATION I

""°'!_, r..*1,n

~ ~ ~ ~

~ EfilJill.

EZ.B

~ -----------+----1--------------------------+-----------+-------41-------------+-------------------------+-----------

d.....1~""

,1

~~ ~ CNVX l

B ;1'- LIQ. RADWSf.

J.A 6 :I,IS(!Vl~TRNNB

r: c A :J; CW/lESET l__ FCV 254-

.l FC~254

'f.,

J;'

BT CS/RESET AJCg/NEUt T cNV CN~T P(!)Ll?J2 y P©l RI2 RtSET E4B ESB El-fO El-21 lRM LRAR PM184t PMl84i l 3RIB 1-3RIBXI 3RIB 3RIBXI 2i~7

---7

'~ I

~"-lQ._11

"" r:=:! I

~

'! I aJT°'T :

C, 180-L.l l ~~~i r---

N Ill 111

~o

__ _J

___..J IJ\\

I-,-

i "'t' I

I SV513 u

FCV254

~~

g I,\\

t-Nl-3 ll1 II f?AR Nl*3~

N.Ill

~

Nl-2 SA N~

CNV

~l.f'G 4 Si~..

B csi~ELI'f" TA RESET ?PilLRl2 El-22.

El-23 PMl849 PMl84i 3RIBX2 3RI5)(2-

__ _ 7

~o.L,__11

~T"'T "'T I 0-1~0-1:

- (,'}Tu7 U1T j

~J ___ J 3

R3T PG)GI?

1-5 PUl84-1 FCV2~7 ° FCV'b7 l CS/RESET TB CS/1-iEUT. TA POL RI~ y RE$E.T ~ P(!)LR12 El-24 El*25 PMl84-~

Pt.1184 i 3RIBX3 rocv1 ~~3.x -- 7

~: -~~~t:

I

~ 1 I

1

<Ll:

3R3 Xf>ipSll96!

PG5H'1(;l 6 CL/FCV2~~

3RIBX3 fl.!al-1 i7

..!.a o.. cu. I

~T,i I I

o.l.J... 11

'i 01"'T 1 R3X LJ '1 __ J LJ _ _ _ _J S6/C I I

-:1POS?57-I


r. __,,.____

j)

SV532 N~2 I

XP~51190 SV515 Nl-2 FCYZ57 PMl84 Nl-2 FCVZ56 Pl.1184 Pl-1184 FCV"lOI.l FCV50I...L r.smESET Tl'> CS/NEUT. TA R l 0LRI2~

RESET y P~LRIZ EJ-26 El*27 PIA/23 Pllll23f 3R5 3RIBX4 J ~

~ 3R I 6 X4 1 -- -

7 I

~

u.l. CLl I l ; 1 i"'T 1 l ~~t~1 !

L

_ _J SV519 FCY50I

~512{'8 Nl*2 PMl23 FCV260 lr, FCV2/o0 lA

~J CS/NEUT. T R) P~LRI2~

NESn yPl)LRU Et-28 El -29 PMl239 Pi.1123..i 3RIB-X5 3Rl3X5

- ---7

~LJCLl I

..;Ti(l)T I I

I g;t~~t I

.___J _ _ _ _J SY533 fCV260

POCI/ I - IO POCV I - IO :

S6 / C I 3 G

S6/ CI 2 R

GPOS?60 - I G :

clPOS2 f,0 - IR :

PillCYI P~CVI 3GI' 31<9 XPSl211 XP~Sl2lli

~

PGSl211 B

Offf<Vl60 (L/FCV21,0 A ______ __,

~Pms1211 I

Nl*2 I PMl23 PMIB4'('Nl*~~~----------------------------~:: ~==::~~~~~----------------------------1-----------------------_J

,~::'

l..lQIUID RADWASTE ISOLATION_ Y_6LVE_$_:_~I_R_C~ll NO. I051JSY_0J KEY DWG.

SECT !Qrl 4

NUCLEAR SAFETY RELATED 1

CIRCUITS_ LISTf_Q___Ot-1 DW6. 103072

~

VALVE ND',. : fLV15l, 254, 255,tH,, t51, 7.58, 'll>O, soo,so,,618.

DATE REV I SION DESCRIPTJ ON 08-29-20 1 I d-.

__,,~.o~,

,EVISEC PER DAS-6 * <26-0

~/RQDm. ""~

D. D.

~~NRU R. E.

SM85 l. \\',

P. E. I R2M5 Ul~ IT I

EL ECTRICAL SCHE MA TIC DIAGRA~

L IQU I D RA DWASTE SO L ENOI D VA LVES O! ADLO CANY CN POW~R PL A~T PACI F I C GAS AND EL ECT R IC CO~PA NY SAN FRANCISCO, CALIF ORSI A 0\\.-/G SC/1LE:

e!LL OF MATL :

SIJPSDS :

SUPSD BY :

DRPWING 437584

~

_}__

B C

P.G. &E. SYSTEM PHASE ::-EOUEMCE A-C- [l SH Ec-I FAGE I REV o I 16 IJ 2 - 44 I 3I9 F"OLD roLD sr co

<£)....

sr Oi..D~

1)1 0..

CU<