1 to Updated Final Safety Analysis Report, Chapter 9, Figure 9.4-8, Building Service System Flow Diagram Auxiliary Building Charcoal Exhaust System Flow Diagram
ML21209A333
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A333 (1)


Text

14 13 12 11 10 9 8 7 6 5 4 3 2 1 SYSTEM ()f'ERATINC, DATA

/\ XDP-9A-20A-AH ----..

-- -42,595 **

AIR TEMP LQ.[:,

I S.F. PIT S.F. PIT SEAL WTR. WASTE GAS FLOOR DRAIN SEAL WTR. !NJ. ~---,Y

2. _ 45 580_ PURIF. FILTER 'B' PURI F. FILTER "A" RETURN FILTER DRAIN FILTER TK. FILTER FIL TER 'A' A

~

4 42,595 34,595 45,580 17,830 40 CFM 40 CFM 40 CFM 1-------+---.._---+-- ------il------t--------t ---"I.E 40 CFM 40 CFM 40 CFM 1 I


7 I

I A

I 7 5,820 I I

B 17,570 I

"' 7,220- + - - - - + - - - - - - - I NB DEMIN NB DEMIN SPENT RElYlLE RECYCLE RECYCLE WIISTE WA51E WASTE RE/IC SEl\l N ll Sf'E. NT OUTLET INLET RESIN EV/IP EVAP EVAP E VAP MONITOR EV/IP COOL WTR /NJ flESJH 10 10,180

  • F££D CONO TK FCEO fCILTER FILTER B SL I/ICE FILTER FILT ER SLUICE CON CONC 11 17,395 40 CFM 40 CFM FILTER FILTCR. FILTER FILTER. ,{-11 CFM fD CFM FILTLR FILTER FILTER FILTER IZ 3,440 40 CFM 40 CFM ,{-O CFM +O CFM 40 CFM 40 CFM 40 CFM 40 CFM ~ D P IOC-AH B

l I

- . - - - - - - - - - - - - - - - - - - - - -.....----.----..---+-------...- ---*<:D J_ NMES

<?'

I B BLWDN MIXED BLWDN MIXED WASTE RECYCLE RECYCLE RECYCLE WASTE CATION MIXED 8£0 MIXED BED SF COOl/tlG-BED DEMIN A BED DEMIN B EVAP CON EVAP CON EVAP FEED EVAP FEED MONITOR OEMIN OEMIN A DEMIH B DEMIN 320 CFM 320 CFM DEMIN DEMIN DEMIN A DEMIN B OEMJN /,{-0 CFM /40 CFM /4D CFM 140 CF'M 140 CFM 14 0 CFM 140 CFM 140 CF M 140 CFM I FC SAFl:-TY CLA55 VERI FICA.Tl ON ORIGINATED BY AUX BLOG REVIEWED BY CHAR PLENUM,._

IE,OO CFM _ FL EL 485*0 '

C C r---------14 XFD 2~O-AH NOTE VALVE VOLUME CONTROL AUX BLDG 800 CFM 2200 CFM JO00CFM 800 CFM GALLERY TANK ROOM CHAR PLENUM FHB FMB EXH FHB CH.IIRC0/\L FHB CHARC0.l\l 430 CFM 390 CFM ROOM B CHARCOAL FIIN ROOM PLCNUM PLENUM

/60D CFM PLENUM Fl.DOM B ROOM A ROOM C D FL E\. 4<o3 0 D st w

12 1-------~------"T'"--------------------+----,-------,-------,

SM,/IPLE DEMIN TANK BLOWOOWN VALVE C,ALLERY r---,--+-....-_::_:;----,~-----t:---t ----------"-:-,------:.-,r l ('.,

XMD-4'1-AH\

...---XM D 4 5 I\ H

\XMD-4'.3-A H

>-----::ir--t t

'2 uJ A4 a, "' C:

CD DEMIN TANK OEMIN TANK ROOM 300 CFM HOLD UP TANK

'530 CFM IGIOCFM VALVE GALLERY 900 CFM Z UFC DAY TAIJK VEI.JT 302 732 r=c'7"".:-,... RM

<-=.:-:'-:-'.::.:,,- All

~;"' ' :>: ROOM VAl..VE GALLERY (TYPICAL FOR 2) WD

~

300 CFM 400 CFM

"' NOTES' a: ([

300C.FM BORIC ACID Pl/MP ARCA 260 CFM BORON THERMAL REGEN DEMIN 210 CFM BORIC ACID PUMP AREA 260 CFM XM0-41o-/\H 1-\IG,.lt

£m~l UREA/CATALYST LOW' P.IICK.-.GINC, PROCES-!>

CNS! EQUIP NORM 2535 CF MAX. 100CFM W/",.5TE TRUCIC ITYP FOR 41 LEVEL STORAGE TANK I...E"EL MODULE MODULE l:lLEtlDING ACCESS AREA.

E BORON THERMAL SHl[LO S"TORl>..C,.E AREA ':>TORA<.,E l'1--SSCFM 325CFM TANK AREA E RE6EN DEMIN SLAB '&"l-5OCFM VALVE c;.ALLERY IO'Z.':> CFM. 675 CFM to,OC.FM. '300 CFM

_ _ _ _ _ _ _ _ _ __ _ 10';,0 CFM _ _ _ _ _ _ 3100 CFM_ _ _ _ _ __ ___

- - - - - - - - 1 1 - - - - - - - - - - - - -- ---------- ------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - F L EL '136-0 SHIELD SLAB F 10 3870 CFM 30Z"l32

,NOTE WD BLANKED

!,M,.\PLE OFF LETDOWN CHILL EF\ MODERATING XMD-39-AH AHR/HEAT

[XCHANGERS HEAT EXCHANGER HEAT EXCHANGER ACCESS TO RECIRC VALVES Wl'*l:,tE

'l.~~C.FM.

SHIELD SLAB 400 CFM SEAL WATER HEAT EXCHANGER RECY CLE EVAPORAT OR 2 400 CFM SAMPLE

~

o 41 AH 1350 CFM 270 C FM 400 CFM 1300 CFM , G' 450 CFM B-11 ~

NOTES {TYPICAL FOR 2) C10 SH. 2 426 - NOTE_5' I WA51E \/AP (DJC TANI', VENT SHEILD @ ~l11_4_E0_7_7> wAso~E~~APo4A.T~

SLAB F 1150 CFM Kill c- 5 ,._,__ RE.c.'(c.LE EV~oRA.,oq, 4 F

\5,1 1_114E075..,,..-* VE.t-.l'T

- - -HORTH

- ---PIPE --- --------- - -

V~LV!c. AREA

-- - ---- - FL EL 412 0

.3'100 CF'M ~ NOTE 5 XMD-40-A H >CMD-'10-AH~

__________.________...,.....---,..-------------- -----1-------10p >--.-.:----t,~-..,

GAS DEC.I\Y GAS HYDRO TEST H 2 RECOMBINER SOUTH PIPE H2 RECOMBINERS £,AS GAS RECYCLE NORMAL GEN FLR AREA SAMPL.E GAS DECAY SHEILD SLAB TANKS 430 C.FM VALVE GALLERY 770 CFM TANKS DECAY TANKS 430 CFM I PUMP 1120 CFM GAS ANALYZER PANEL VALVE AREA 4100 CFM 200 CFM

!TYPICAL FOR 21 COMPRESSOR ENTRANCE ABOVE GAS COMPRESSOR FEED PUMP SLAB 1210 C FM ~ (j)

COMPRESSOR AREA 275 CFM EL 400' - 0' d, (TYPICAL FUR 4) ITYP FOR 21 430 CFM (TYPICAL FOR 2) 1120 CFM 395 (FM 3000 CFM 230 CFM ABOVE CHARGING /

ITYP FOR 21 WASTE EVAP G ITYP FOR 2) SI PUMPS G i-Jo1"ES * ~ 2 WAS TE GAS t,1(>1E5 DECAY TANK (E

E b 302 7-42 I _AN01E !:,

CONC PUMP RM 200 CFM CHARGI NG/SI 1500 CFM

~ VE NT WO PUMPS 710 CFM ITYP FOR 4)

FL f:L ~-q-, __o ___ _ __ FL EL 388-0 NORTH Bl3 J 8 SHT 3 CHEM DRAIN

':>AMPLE 80~00 RM All I ME0 77 . TANK VENT

©------- P."1 J 3 SHT 4


="---'~F==L=~OR~DR_A~IN~_ Q14[_9!ll QUALl"fY RE.LAl'ED 'FAe.RICA"\'\O>J, RHR/SPRAY WASTE TANII. VENT EfW..C1"101'l AIJO \\.l!:.PE.C1\0IJ PCR bCE( G H /}-L-;:::::==::::;=== i-----,--,-7 AUX. BLOG MISC WASTE PUMP AREAS 1B30 CFM HOLDUP TANK NOTES:

Ci,lF\P FOR 1-\VAC OuCTb A1'10 t.U'PPORT6' H

SUMP PUMP DRAIN TANK ITYP FOR 2) 1160 CFM I.EXCEPT WHERE NOTED OTHERWISE XMD-41-AH J LOBBY 650 CFM NUCLEAR BLON DRAIN & RUPTURE RESERVOIR RESERVOIR ACCESS UNASSIGNED ROOM 855 CFM AREA b35 CFM 9b'5 CFM ALL ALARMS & INDICATING LIGHTS ARE LOCATED AT THE HVAC CONTROL 635 CFM 635 CFM BOARD IXCP-62101 IN THE MAIN

~ DTE 5 CONTROL ROOM.

2. lfl!NDICATES INSTR. IS FURNISHED FL. EL 374'-0" SOUTH WITH EQUIPMENT.

ALL COMP01'-JEt,....JTS OF THIS SY=>TEM ARE "-lOi,...J /.-.JLJCLEAR "=>/\.FETY EXCEPT

3. FOR SAFETY CLASSIFICATION OF INSTRUMENTS.SEE INSTRUM ENT LIST. ESSENTIAL J AS r-JOTE-D 4. SPEC IAL HIGH PRESSURE DUCT CONSTRUCTION J 14 PLACES) XFN-19A-AH AND XFN-19C-AH OR WEST PENETRATION ACCESS AREA. FSAR Figure 9.4-8 XFN-19B-AH AND XFN-19D-AH MUST BE RUNNING TO ALLOW XFN -24A-AH OR XFN-24B -AH TO RUN ASSOCIATED WITH
5. ALL DUCTWORK IDENTIFIED AS QR TO BE FSAR Figure 12.2-2 14 PLACES! FANS MAY BE MANUALLY RE-STARTED WITH AVAILABLE DIESEL POWER AFTER BLACKOUT PER QRP -4. DRAWING LEGIBILITY CLASS 1 SOUTH CAROLINA ELECTRIC &GAS COMPANY XFN -19A-AH OR XFN-19B-AH MUST BE RUNNING
6. ALL EQUIPMENT IDENTIFIED AS QR TO BE SCE&G CAO ENHANCED 12 PLACES! PER TRP-31 THIS IS I'.

VI RGIL C. SUMMER NUCLEAR STAT I ON NUCLEAR SN'ETY RELATED TO AL LOW HCV-014 TO OPEN DOCl,J,IENT . NO DEVIATION SIVU BE INITI... TEO OR PEf!fOIWEO WITHOUT PRIOR OOCUWENTATION #10 WRITTEN APPHOVM.. BUILDING SERVICE SYSTEM FLOW DIAGRAM AUXI LI ARY BUILDING CHARCOAL EXHAUST 4 45 680 65"-95" SYSTEM FLOW DIAGRAM 30 09117102 DJ REVISED PER ECR-70249 MGR DKW K 3 45 000 65'-95' 29 10103/01 OOJ REVISED PER ECR* 70028 MGR DDJ 6 DESIGN ENGINEERING K 2 45 680 65"-95" 28 08108/96 JMR REVISED PER MRF

  • 22305 MGR RLB SCE&G A SCMl/1. COMPANY V. C. SUMMER NUCLEAR STATION JENKINS VILLE S. C.

42,350 55*-95* REVISED PER MRF

  • 21511 MADE

,. CHECKED LE APPROVAL 27 02/10/94 ACI MGR JMG 3.

AIR FLOW AIR TEMP 26 04/22/93 JMH REVIS ED PER CGSS-93-0328 ovw GAA RHM DJL CFM 'F 31 05/1412010 CMS REVISED PER ECR- 72654 chk AJL CALE "10 SCALE D-9 12-125 31 SYST EM DESIGN DATA NO. DATE BY REVISION CKD.BY LE APPROVAL DRAWi NG NU"flE R SHT.NUMBER REV 1/4'"= l ' -0" 0' 5' 10' 15' 20'