ML21209A214

From kanterella
Jump to navigation Jump to search
1 to Updated Final Safety Analysis Report, Chapter 9, Figure 9.2-2, Revision 1, Sheet 3, Piping System Flow Diagram Service Water Cooling B - Train Outside RB
ML21209A214
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A214 (1)


Text

RN 10-012 (Page l of 1) 14 13 SYSTEM DATA ao GPM Ps1c*

"F BY REMARKS 2

901?!0 50 95 NORMAL 7700 50 130 POST ACCID A

3 1000 50 95 NORMAL 820 50 116 POST ACCID 1000 to 45

> 65 NORMAL 600 500 45

> 65 POST ACCID

  • APPROX.

B C

D

[

LOOP 'B' J-9

- 221 SW COUPLING m-19 RE'OI F

G H

J HYDROSTATIC TEST TEMP. 60" 10 125 95 165 95

( 11/.

2 10 RJS 9

16 15 0 20 150

( 11/.

25 ccs B

16 95 20 214

( 11/.

25 ccs 7

16 12 4 20 130 25 WTW LRC K

6 65 124 65 130 82 WTW LRC 5

65 95 65 95 B2 ccs NOTE 3 PSI G F

DURATION HYDR BY CHO REMARK UPSET DESIGN DATA 12 16' 30' VENT X

TE~

!1/21"~%

3 3/4"

~ [

tn UM Lu -

E 13 1/tl":;; I ' -e,,

0' 5'

11 24'x20' l 0' l5' 6'

RN -14 3122B-SW 20' 10 HVAC CH L LER B CONTROL IGAI owe B-20 109 SHT VU02 I

I L-E:j M

q 8

16' 20' ROh-I 7

H~@M (D

L~

4504 I cm I

C SYSTEM MECHANICAL TEA CHI LLER COND 'B' RDh-1 IPX4485B-HR-SW I

I 6

ROh-1

!FT 449I-HR-SW

~

~

4' FM 4490 A

5 Q) !FT 4490-LR-SW BDb-1 ji

\\9;:: - - - ~

TSC

~

l' IPX45I5A-HR-SW COMPONENT COOLING HEAT EXCHANGER 'B' RNh-15 31258-SW 3180B-SW STATJ~~ll~~JNAGE I-------'

LDC. H-11 RN -14

~ T--C)---

20'

~-SW 3/4" (6J7)

-.8.

8' DIESEL GENERATOR

'B' COOLER PX 450

!FT 4492 - LR-SW lPX4506B-HR-5W DG 'B' HJ LUBE OIL/HI WATER L -

JACKET TEMPERATURE LOGIC SEE GAi DWG 0 -802- 0 14. SHT 5

] IDRA!Nl 13I27-SW 4

16' (ill)

I MRF-21746 31958-SW I

COUPLING RNm-6 7

8 RETURN TO S.W. POND 0'

J 16' 20*xt6' COUPLING RNm-7 C8 RE"OI ROi -21 3130B-SW NOTE 11 COUPLING RNm-7 13 RED'OI PENDlNG/HOLD CHG Use With reference to ECR: 50585/1; DATE: 'f -1,j-/o INITlALS: CVT 2

NOTES, I. ALL PIPING TO BE LINE SPEC 152N.

EXCEPT AS NOTED.

3. TEMP CORRESPONDING TO PERTlNENT HEAT EXCHANGER OUTLET.
5. ALL STATUS LIGHT INDICATE BOTH OPEN ANO CLOSED POSITIONS.
6.
  • DENOTES MISSION DUO CHECK OR EUAL,
9. RECORDER SHARED WITH REACTOR BLOG SPRAY PUMP FLOW INSTRUMENTATION.
11. XVC03130 A/B MAY NOT PROVIDE ADEQUATE lSOLATrON FOR USE AS A BOUNDARY DURING SYS TEM DRAINING.

REFERENCE NCN5063 OISP. ' 4.

12, 8' SW-TO-EF X-CONNECT PIPING FROM 24' HEADER TO INLET FLANGE OF TEE 15 LINED WITH CURED-IN-PLACE PIPING TO ELIMINATE CORROSION ANO MIC BUILD-UP, ISEE TR04330-005 & ECR50695I WEKO SEALS INSTALLED INTERNALLY TO PIPING TO SEAL ENDS OF CURED-IN-PLACE PIPELINER.

13. B16.5 150
  • TEE. 316 SST TO RESIST CORROSION AND MIC.
14. 8' SW-TO-EF X-CONNECT PIPING FROM OUTLET FLANGE OF TEE TO INLET OF XVG0I037B-EF IS COATED WITH PLASTOCOR TO ELIMINATE CORROSION ANO MIC BUILD-UP.
15. XPS-0235 IS A 3/4" SST SPACER RING INSTALLED BY ECR-50695 THIS 15 A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVJATIDN SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR FIGURE 9.2-2 SH.3 PIPING SOOTll CARO.INA ELECTRIC & GAS C01PANY VIRGIL C. Sll1HER NIJClEAR STATlON SYSTEM FLOW DlAGRAM SERVICE WATER COOLING B - TRAIN OUTSIDE RB A

B C

D

[

F G

H DESIGN ENGINEERING K

~-+---+--+------------+---+-- ; 1, SCMA~MT V. C. SlMMER MJCLEAA STATION..ENKINS\\'ILLE S. C.

4/JO/n RHM REVISED PER ECR-50695 0

V6/0'l JNC REVISED PER ECR-71215 NO.

DATE BY REVISION MGR WTW PAH MCC LE CKD. BY N'PROVAI...

MN>E CHECl<ED LE APPROV,.._

JNC PAH MGC D-302-222 3

SHT. N..1,1~

REV