8 9 10 11 12 7 SEE DWG 2049 SHT 1, ZONE B-9 NOTES:
- 1. ALL PIPING SYSTEMS SUFFIXED BY AN A *s* ARE STAINLESS STEEL (i.e. MW-2S, CH-4S). A
- 2. FOR CONNECTED PIPE SYSTEMS AT CLEAN-OUTS VENTS DO NOT FABRICATED OF BOTH STAINLESS STEEL AND EXTEND THRU CARBON STEEL SEE PHYSICAL DWGS FOR ROOF (TYP) TYPICAL BREAK POINT.
- 3. FOR LEGEND SEE DWG 2001 SHT 1.
EL.918'-6" 4. FURNISHED UNDER CONTRACT E-68-34.
- 5. F(WC) IS CODING FOR FLANGE MOUNTED SAMPLE RACK 1-G WAFER CHECK.
SAMPLE SINK SECTION "C" 4" 4" 4" SAMPLE RACK 1-G 4"MW-2 SAMPLE SINK SECTION "A" z 0
0 O'l "'I
.::: SEE DWG 2049 B VENT or---lD et::Z SHT 1, ZONE B-9 B EL.903'-6" ,<(OW 00 ¢ WO N z r~ .:C
<( I I N
~c.,N _J U I
_J Ia_~ ,.,.,* ~:J =....._N 3:
N I
3:
0 u
U>~""
0 2 1-Li.I U u~a..
zu::::!:
Q_
3" I<<:r: ow=:i
(/)
N EL.903'-6" "' EL.888'-8" a_>-"'
, u et: a_ EL.903'-6" I 3:
(/)
N 3'MW-2S SEE DWG 2049 I SEE DETAIL "A" 3"PW-2 SHT 1 ZONE E-10 SEE DETAIL "A" 3: 3" 4"
@ @ '"' 4"MW-2S I
N I
..,- ..,- 4'MW-2S 4'MW-2S 3: 3: 1 1 I I SEE DWG 2049 SEE DWG 2049
,u u Q_ Q_
- ,, (793) (800) SEE DWG 2049 SHT 1, ZONE D-8 SHT 1, ZONE E-10
-a SEE DWG 2049
~ ~
SHT 1 ZONE F-9 SHT 1, ZONE D-10 "'wI "I C I u
"I I C
~ ~A ~ ;-- ~ ~A ~I ~~I ~ "'w <°I
~
- - - ;-- l I - - - - - >-Z (Il I~
0 - u 2'V253X-(il~~ I (792) I "I "I 2"V226X-1567 (798) I (799) I 2"V226X-1566 0 0 I w ON w
- 0 w
(114CV) 1 I
LI2'V253X-1571 I
,u I
,u (117CV)1 LI
(/) (/)
I u
u_ N ~
,,------L __ ____j I
"'w "'w
~ >- ~ >-
I
,,------L __ ____j I _J _J =
.N Ct:'. 1-oI "'0 2'V323F(~)~7~ A "'
w "'
w 2"V326F(~)~6~ A 0 0 .=,-.. t-: (/)
~!la A
~ ~ _J _J A
~ ~ ~"'
>- r-. >- ::, '0 15 C: C:
~ ~ '-' '-' zo
< < ,,,I I SEE I I SEE I WN i:Ja_
SEE NOTE 4 ~ NOTE 4 A )
"'w "'t;:w "'t;:w w w NOTE 4 A ) "-
b b
u z c:, u"'
Zz SEE NOTE 4
"'I "'+ 03:
Q_ Q_
I
- II u uo 0 Ue-
<(
EL.877'-6"
--+,
<( <( Q_ Q_
EL.877'-6" 2" 2" w w
"'~ "'~ (1163)
EQUIPMENT DRAIN_-,-- 121 121 1 - -. .t-cl SUMP PUMP 3" 3" 4" 3" 3" I I 3" 3" 4" 3" 3" 3" I I 1-BB 4"PW-2 3"MW-2S D 11/2" 11/2" 4" 3" 4" 3" 3" 3" 3" 3" (1164) D LJ 4"PW-2 VENT 3"PW-2 CONCENTRATOR HEAT EXCHANGER SHELL SIDE VENT LJ 4"MW-2S EL.929'-6" SEE DWG 2049 EQUIPMENT DRAIN "'0 0
SHT 1 ZONE B-8 CHEMICAL SUMP BB SUMP CC
"' CHEMICAL DRAINS CHEMICAL DRAIN EQUIPMENT DRAINS SUMP PUMP 1-CC E E 3"
0
"'I EL.918-6" DELUGE VALVE ASSY "B" DELUGE VALVE ASSY "A"
" ' (Il 6"RD 0
Oz w (TYP)
~ NO ROOF c:, N FOR CONTINUATION SEE 3" 3/4"RD-2
~ ~ .- DWG 2013, ZONE B-4 3" 4" 3" 6'
~ we' WI 4"FDR-2 1 1/2" RD-2 3/4"RD-2 z>- (/) (/) 1/2"Dw-1s w
u 1---IXI ( 427) z ..,- ~
EL.914' -Q"
~~~-~--,---, I 8 I ~ --+DW-1S 6"RD-2 8"RD-2
,u
"'0 0
~
OC)
CH-4 w"'
e-O
~
"'I UlO
"'0 "'0 "'
_J X c..,
z c..,
z
~
(Il
~
(Il
~"'
0 _J
(/) 0 <O <!O
"'x "'>-Z 0 (/)0
- J :J
"'0"' "'0"' "'::,u "' 8"RD-2 TO RIVER VIA EXISTING N
I~
- , "' w"'
Ul~
u"'
<("'
c:,
u_ Z
>- N
> ::, Z 0 ::, Z 0 u
- , UNDERGROUND YARD PIPING 00 uO "-0 ' 0 0
"'>- "'>- :::, 0 F F
"'<( "'<(
EL.903' -6" UlU <(U OU 0 I Ct: 0 I Ct:
<< u EL.903' -6" ROOF DRAINS 3" 3" 4' 3" 3" 3" 3" 3" TO HOTWELL SEE DWG 2035 SHT 4, ZONE G-8 3"FDR-1 4"FDR-2 4"FDR-2 6" SEE DETAIL "A"
-~~-tDW-1S SEE DWG 2049 , - ~ 1/2"Dw-1s ::, 1/2"V226X-1580 ..,- ..,-
SHT 1 ZONE E-10 6" "':r:I N w
1 1
- o (379) ~
- ;:_(_3_8_0) p >- w (Il w
w z 1/2"V226X-1579 I a.. . . .,,
_J (/)
w . CH-4 z (/) c:,z c..,
Ow ~V) a::a::: (573) (570) 3: 0 3: 0 U>
>- _J FOR CONT. SEE I< 0:8 3/4" Vl 53X t><l--l >- N Oo "'w ON
"'wU1 ON
"'u - - - f - ,----,, "'"' - - - CF-596 w* w *
"'0
<(
_J DWG 2013, ZONE A-5 EL.894' -0" 0,,,
SEE DETAIL "A" "'> EL.888' -8" ~=~~~-+
(/)
z z- z z-(/) 0 w >- >- w >- >-
~ - - - ---... A r-1~ A ;-- I - - -~
00 U<O 0
z o.,
0 :r:
0 (/)
0 z 0 :r:
0 (/)
G I 3/4'V253X 3" 3" (568) I (569) u- "'00 Ul N 0
u-(Il
"'0 0 U1 N A B C G 3" 2"V253X-1562 2'V253X-1564 u"' u,,,
"'"- (1314)
"'zW"'>-
0 0 0 6"FDR-2 WO WO (796) (797) (24CV)1 I 2'V3d3F(WC) 1565 WO WO RW-Pl-2450 RW-V-841 RW-V-842
(/) <O U1 <O 2'V323F(WC)1563 I (25cyi ~ ~
-B SEE DWG 2049 RW-Pl-2451 RW-V-835 RW-V-836 3: (/)
"'I i::'i SEE DWG 2049-,-... SEE DWG 2049 -7'-.. SHT 1 ZONE F-8 , - - - 7. A ;--*~ A , - ~
"' e-
~ ~~ ~ "' SHT 1 ZONE F-10 SHT 1 ZONE D-10 z (B)
- - - -----..,. f\. A - - - - 0 z<< ow RW-Pl-2452 RW-V-838 RW-V-839 e- >
w :; "' ..,- A )
2"V253X-1558 (794) I 2"V253X-1559 (795) z 0
N
"'w 0 _J
..,- ..,- I 1 V HH SEAL PLATE SEAL PLATE RW-PI-2453 RW-V-844 RW-V-845 0 SEE NOTE 4
"'0 N
I 1 1 .u NOTE 4 EL.877'-6" Ct: N au
"'[2 I I CF-Pl-2454 CF-V-575 CF-V-574 (115CV) I 2"V323F(WC)1561 0
.u .u j g ~
tic *,,,
2"V323F(WC)1560 (116CV) ~ (/) _J (C)
~ ~ 2" 2*
"'00 ~ ~ SEALED w "- 0 CF-Pl-2455 CF-V-572 CF-V-571 Z-a, z w\c "'0 w w PLATE 3"CH-4S LI
"'0 "'0
_J _J
_J w r-. _J _J _J
'0 '0
<( 0
_J c.., _J w w
"' ~ ~
(Il c..,"'
,,,I 0 <( 0 0 I
~ ::> 0 N >"'
Ow "'w "'"'0 "'"'0 ~
Q_
w w
"'> CJ "'
<( 0 '-'
~ ~S2~ WO G: u u ~ ::, Q_ Q_
DETAIL "A" 2"
(/) (/) (/) 0 "'u (/) Q_ Q_ Q_
EL.877'-6" H H SEE NOTE 4 3"
- <O 3" 3" 3" 3" .,___, 3" 3" 3" 11/2" 11/2" 4"FDR-2 3"FDR-2 3" 4"FDR-2 3"FDR-2 CONDENSATE 3" CONDENSATE DRAIN SUMP PUMP 1DD-1 SUMP DD 4"FDR-2 AS BUILT CONDENSATE DRAIN BUILDING 101 FLOOR DRAIN, SUMP PUMP 1DD-2 FLOOR DRAIN FLOOR DRAIN LAVATORY & SHOWER DRAIN 454003675 SUMP PUMP SUMP PUMP lAA-1 lAA-2 CONDENSATE DRAINS STATUS: Release FLOOR DRAINS STATUS DATE: 09/09/2020 DS APPROVED: JDMADDO FLOOR DRAIN VER: AB REV: 16 SIZE: F SUMP AA J SIGNIFICANT NUIIIBER DRAWN RGA DATE 3/10/05 J
GROUP
' ' 4
' ' CHEO<ED DATE BURNS & ROE ~
NO.
VERSIONS/REVISIONS BY NPPD DESCRIPTION ORDER DFT DATE ENG COOPER NUCLEAR STATION g AB 16 DR-2016-0219 06-041 DJB 9 09 JDMADDO FLOW DIAGRAM APPROVED DATE
"'0 1----r---~----------i.
0 AUGMENTED RADWASTE BUILDING ~u 2080 FILMED EQUIPMENT, CHEMICAL & FLOOR DRAINS ~
1 2 3 4 5 6 7 8 9 10 11 12