.....I CONTAINMENT PENETRATION LOCATION LINE TYPE "B" lYPE "C" TESTABLE ISOLATION VALVES CONTAINMENT PENETRATION LOCATION LINE TYPE "B" lYPE "C" TESTABLE ISOLATION VALVES QlY. LINE DESCRIPTION REMARKS QlY. LINE DESCRIPTION REMARKS PENETRATION SIZE ELEVATION AZIMUTH SIZE TESTABLE PENETR. (INBOARD, OUTBOARD) PENETRATION SIZE ELEVATION AZIMUTH SIZE TESTABLE PENETR. (INBOARD, OUTBOARD)

X-1A 10'-0" I.D. 907'-3 .. 135" - 1 EQUIPMENT HATCH SEE SECTION 33 DWG. 4262 (REF. ONLY) DOUBLE 0-RING X-36 6" gso'-o" 175" 3" 1 Hz/Oz MONITORING SAMPLE LINES (SEE NOTE 4 & 6) IF MODIFIED X-1B 10'-0" J.D. 907'-3" 315" - 1 EQUIPMENT HATCH SEE SECTION 33 DWG. 4262 (REF. ONLY) DOUBLE 0-RING X-37A 3'-9"W x 2'-6"H 918'-10" 75* 1* 32 31 CRD WATER INSERT, 1 SPARE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY)

X-2 8'-6" I.D. 907-'11" o* - 1 PERSONNEL ACCESS AIR LOCK SEE SECTION 21 DWG. 4262 (REF. ONLY) DOUBLE 0-RING X-37B 4'-7"W x 2'-6"H 918'-10* 105' 1* 38 37 CRD WATER INSERT. 1 SPARE SEE DETAIL 28 & 30. DWG. 4262 (REF. ONLY)

X-4 24" 1.0. DRYWELL HEAD 135' 5'-10'" I.D. 1 DRYWELL HEAD ACCESS HATCH 1a* -o* R FROM Cl DRYWELL HEAD DOUBLE 0-RING X-37C 4'-7"W x 2'-6"H 918'-10* 255' 1* 39 38 CRD WATER INSERT, CRD MINI PURGE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY) CRD-14CV, CRD-13CV X-SA 6'-11 1/2" 892'-5" 25* s*-10* I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-37D 3'-9"W x 2"-6"H 918"-10" 285' 1* 32 31 CRD WATER INSERT, 1 SPARE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY)

X-SB 6'-11 1/2" 892'-5" 70' 5'-10" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-38A 3'-9"W x 2'-6"H 918'-10" 75* 1* 32 31 CRD WATER WITHDRAWAL, 1 SPARE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY) x-sc 6'-11 1/2" 892'-5" 11 s* 5'-10" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-38B 4'-7"W x 2'-6"H 918'-10" 105' 1* 38 37 CRD WATER WITHDRAWAL, 1 SPARE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY)

X-SD 6'-11 1/2" 892'-5" 160' 5'-10" l.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-38C 4'-7"W x 2'-6"H 918'-10" 255' 1* 39 38 CRD WATER WITHDRAWAL, CRD MINI PURGE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY) CRD-16CV, CRD-1 SCV X-5E 6'-11 1/2" 892'-5" 200* s' -1 o" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-38D 3'-9"W x 2'-6"H 918'-10" 285' 1* 32 31 CRD WATER WITHDRAWAL, 1 SPARE SEE DETAIL 28 & 30, DWG. 4262 (REF. ONLY)

X-5F 6'-11 1/2" 892'-5" 245' 5'-10" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-39A 12* 934'-6" 40' 12* 1 RHR DRYWELL SPRAY LOOP A (SEE NOTE 1 & 7) RHR-M031A X-SG 6'-11 1/2" 892'-5" 290' 5'-10" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED X-39B 12* 920'-10* 299' 12* 1 RHR DRYWELL SPRAY LOOP B (SEE NOTE 1 , 5 & 7) RHR-M031B FOR RHR X-SH 6'-11 1/2" 892'-5 11 335* 5'-10" I.D. 1 VENT LINE DRYWELL TO TORUS lYPE "A" TESTED PC-1311MV, PC-1312MV FOR SBNI X-6 24"' 905'-3" 37* - 1 CRD REMOVAL HATCH DOUBLE 0-RING X-40A 10* 920'-10* 49* 1* 7 X-40A(a-f) JET PUMP INSTR. TO BCV SEE SECTION 6-6 X-7A 42" 908'-4" 160' 24" 1 MS TO TURBINE SEE SECTION 4-4 BELLOWS MS-A080A, MS-A086A X-40A COUPLING PC PRESSURE INSTR. (SEE NOTE 4 & 6)

X-7B 42" 908'-4" 175' 24" 1 MS TO TURBINE SEE SECTION 4-4 BELLOWS MS-A080B, MS-A086B X-40B 10* 920'-10" 53' 1* 7 X-40B(a-f) JET PUMP INSTR. TO BCV SEE SECTION 6-6 X-7C 42" 908'-4" 185' 24" 1 MS TO TURBINE SEE SECTION 4-4 BELLOWS MS-A080C, MS-A086C X-40B COUPLING PC PRESSURE INSTR. (SEE NOTE 4 & 6)

X-7D 42" 908'-4" 200' 24" 1 MS TO TURBINE SEE SECTION 4-4 BELLOWS MS-A080D, MS-A086D X-40C 10* 919'-1" 239' 1* 7 X-40C(a-f) JET PUMP INSTR. TO BCV SEE SECTION 7-7 X-8 18" 904'-10" 180' 3" 1 CONDENSATE DRAIN (MAIN STEAM) MS-M074, MS-M077 X-40C COUPLING PC PRESSURE INSTR. (SEE NOTE 4 & 6)

X-9A 34" 913'-7" 170' 18" 1 FW WITH RWCU AND RCIC INJECTION LINES SEE SECTION 4-4 BELLOWS RF-16CV, RF-15CV FOR FW X-40D 10* 919'-1" 244' 1* 7 X-40D(a-f) JET PUMP INSTR. TO BCV SEE SECTION 7-7 RF-16CV, RCIC-26CV FOR RCJC X-40D COUPLING PC PRESSURE INSTR. (SEE NOTE 4 & 6)

RF-16CV, RWCU-15CV FOR RWCU X-41 6" 967'-6" 345* 1* 1 REACTOR WATER SAMPLE RR-741AV, RR-740AV X-9B 34" 913'-7" 190' 1 a" 1 FW WITH HPCI INJECTION LINES SEE SECTION 4-4 BELLOWS RF-14CV, RF-13CV FOR FW X-42 4" 962'-6" 150' 1 1/2" 1 SLC INJECTION SLC-13CV, SLC-12CV RF-14CV, HPCl-29CV FOR HPCI X-43 18" 920*-s* 11 s* 4" 1 RR PUMP FLUSHING & ILRT TEST CONN. SEE SECTION 7-7 DOUBLE 0-RING X-10 18" 920'-10" 190' 3" 1 RCJC STEAM RCIC-M015, RCIC-M016 X-44 18" 920'-6" 125* 4" 1 RR PUMP FLUSHING & ILRT TEST CONN. SEE SECTION 7-7 DOUBLE 0-RING X-11 26" 906'-6" 335* 1o" 1 HPCI STEAM SEE SECTION 5-5, HPCI-M015, HPCI-M016 X-45 12* 920'-10 1/2" 245' IL-1 1_:~-11,.;_,,._ 6 X-45(A,B,E & F) SPARE SEE SECTION 7-7, lYPE "A" TESTED PITCH DOWN s* FROM FACE OF DRYWELL X-45(C) RAD MONITOR VENT (SEE NOTE 1) RMV-12AV, RMV-13AV X-12 36" 907'-o" 20* 20" 1 SHUTDOWN SUPPLY TO RHR PUMPS SEE SECTION 5-5 (SEE NOTE 7) RHR-M017 X-45(D) SOV AIR EXHAUST TO DRYWELL (SEE NOTE 1) PC-35CV, PC-36CV X-13A 42" 912'-2 7/16" 25' 24" 1 RHR INJECTION (SEE NOTE 7) RHR-M025A X-46 1a* 920'-10* 155' 1* 6 X-46(A-F) SPARE SEE SECTION 7-7, lYPE "A" TESTED X-47 1a* 920'-10* 160' 1* 6 X-47(A,C-F) SPARE SEE SECTION 7-7, lYPE "A" TESTED X-13B 42" 912'-2 7/16" 340' 24" 1 RHR INJECTION (SEE NOTE 7) RHR-M025B X-47(B) INSTRUMENT LINE TO CV OR BCV (SEE NOTE 6)

X-48 10* 898'-9" 166' 10" 1 SPARE lYPE "A" TESTED X-14 22" 946'-0" 20* 6" 1 RWCU FROM RECIRC PUMPS RWCU-M015, RWCU-M018 X-49 1a* 918'-6" 55* 1* 6 X-49(A,B & E,F) SPARE SEE SECTION 6-6, lYPE "A" TESTED X-15 20" 947'-6 .. 340' - 1 SPARE lYPE "A" TESTED X-49(C & D) ELECTRICAL PEN. ELEC. PENETR.

X-16A 26" 946'-3" 1oo* 1o" 1 CS A PUMP DISCHARGE (SEE NOTE 7) CS-M012A X-50 10* 920'-10" 235' 1* 6 X-50(A,B) ELECTRICAL PEN. SEE SECTION 7-7 ELEC. PENETR.

X-16B 26" 946'-3" 260' 1o" 1 CS B PUMP DISCHARGE (SEE NOTE 7) CS-M012B X-50(C,D) SPARE lYPE "A" TESTED X-17 22" 967'-6" 337' 6" 1 SPARE lYPE "A" TESTED X-50(E,F) INSTR. LINE TO CV OR BCV X-18 6" 898'-9" 32' 3" 1 DRYWELL EQUIPMENT DRAIN PUMP DISCHARGE (SEE NOTE 1) RW-A094, RW-A095 X-51 10* 919'-1" 235' 1* 6 X-51 (A) INSTRUMENT LINE TO BCV SEE SECTION 7-7 X-19 4" 898'-9" 28' 3" 1 DRYWELL FLOOR DRAIN PUMP DISCHARGE (SEE NOTE 1) RW-A082, RW-A083 X-51 (B) SOV TO DRYWELL AIR EXHAUST X-20 8" 920'-10" 55* 4" 1 DRYWELL DEMINERALIZED WATER SUPPLY SEE SECTION 6-6 DW-219, DW-133 X-51 (C,D) SPARE lYPE "A" TESTED X-21 3" 922'-6" 235' 1* 1 SERVICE AIR SEE SECTION 7-7 (SEE NOTE 1) SA-647, SA-648 X-51 (E) DRYWELL VENT MONITOR (SEE NOTE 1) RMV-10AV, RMV-11AV X-22 3" 922'-6" 232' 1" 1 INSTRUMENT AIR SEE SECTION 7-7 (SEE NOTE 1) IA-65CV, IA-78CV X-51 (F) PAS CONT. ATM. SAMPLE (SEE NOTE 1) PC-247AV, PC-248AV X-23 12" 946'-o" 350' 8" 1 CLOSED COOLING WATER DRYWELL SUPPLY (SEE NOTE 2) REC-702MV X-52 10* 920'-10" 45' 1* 6 X-52(A-D) 1" INSTR. LINE TO CV OR BC'i SEE SECTION 6-6 X-24 12" 946'-Q" 1o* 8" 1 CLOSED COOLING WATER DRYWELL RETURN (SEE NOTE 2) REC-709MV X-52(E,F) SPARE lYPE "A" TESTED X-25 20" 896'-o" 235' 20" 1 VENT TO DRYWELL (SEE NOTE 1 & 5) DOUBLE 0-RING PC-232MV, PC-238AV FOR PURGE & VENT X-53 6" 911*-o* 42' 6" 1 SPARE lYPE "A" TESTED FOR INBOARD FLANGE PC-1306MV, PC-1305MV FOR SBNJ X-100A 12* 919'-5" s* 12* 1 LOW VOLTAGE INSTR. & CONTROL SEE SECTION 7-7 ELEC. PENETR.

ON PC-232 X-100B 12* 918'-6" 40' 12* 1 SPARE SEE SECTION 6-6, lYPE "A" TESTED X-26 20" 966'-6" 157' 20" 1 VENT FROM DRYWELL (PC PURGE AND VENT) SEE DWG. GE 11703303 SHT. 5 (REF. ONLY) DOUBLE 0-RING PC-231 MV, PC-246AV FOR LARGE BORE SBGT X-100C 12" 918'-6" 49' 12" 1 SPARE SEE SECTION 6-6, lYPE "A" TESTED (SEE NOTE 1, 4 & 6) FOR INBOARD FLANGE PC-306MV, PC-131 OMV FOR SMALL BORE SBGT X-100D 12" 918'-6" 53* 12" 1 SPARE SEE SECTION 6-6, lYPE "A" TESTED ON PC-232 X-100E 12* 920'-10" 225' 12* 1 THERMOCOUPLES SEE SECTION 7-7 ELEC. PENETR.

X-27 10" 918'-6" 55* 1" 6 X-27(A-D) 1" INSTRUMENT TO BCV SEE SECTION 6-6 X-100F 12* 919'-1" 221' 12* 1 NEUTRON MONITORING SEE SECTION 7-7 ELEC. PENETR.

+-

X27(E & F) SPARE lYPE "A" TESTED X-100G 12* 920'-10" 218' 12* 1 LOW VOLTAGE INSTR. & CONTROL SEE SECTION 7-7 ELEC. PENETR.

X-28 10" 946'-o" 38' 1* 6 X-28(A-E) 1" INSTRUMENT TO BCV X-100H 12* 919'-10* 215' 12* 1 LOW VOLTAGE INSTR. & CONTROL SEE SECTION 7-7 ELEC. PENETR.

X-28(F) FLANGE LEAK DETECTION X-101A 12* 920'-10" 20' 12* 1 MEDIUM VOLTAGE POWER SEE SECTION 6-6 ELEC. PENETR.

X-29 10** 946'-0" 235' 1*. 6 X-29(A-D) 1" INSTRUMENT TO BCV SEE SECTION 3-3, X-101B 12* 919'-5" 24' 12* 1 NEUTRON MONITORING SEE SECTION 6-6 ELEC. PENETR.

X-29(E) IA TO RR-741AV SEE DWG. GE 11703303 SHT. 4 (REF. ONLY) PC-33CV, PC-34CV (SEE NOTE 1) X-101C 12* 920'-10* 28' 12* 1 MEDIUM VOLTAGE POWER SEE SECTION 6-6 ELEC. PENETR.

X-29(F) DRYWELL PRESSURE INDICATION (SEE NOTE 4 & 6) X-101D 12* 920'-10" 335' 12* 1 MEDIUM VOLTAGE POWER SEE SECTION 7-7 ELEC. PENETR.

X-30 10" 911'-6" 265' 1" 6 X-30(A-D) 1" INSTRUMENT TO BCV SEE SECTION 1-1 X-101E 12* 920'-10" 337' 12* 1 LOW VOLTAGE INSTR. & CONTROL SEE SECTION 7-7 ELEC. PENETR.

X-30(E) IA TO NBl-737AV (SEE NOTE 1) NBl-559, NBl-560 X-101F 12* 920'-10" 340' 12" 1 MEDIUM VOLTAGE POWER SEE SECTION 7-7 ELEC. PENETR.

X-30(F) IA TO MS-739AV (SEE NOTE 1) NBJ-561, NBl-562 X-102 12* 920'-10" 3' 12* 1 LOW VOLTAGE INSTR. & CONTROL SEE SECTION 7-7 ELEC. PENETR.

X-31 10" 898'-9" 55* 1* 6 X-31 (A-D) INSTRUMENT TO CV OR BCV SEE SECTION 2-2 X-103 12* 919'-1" 223' 12* 1 NEUTRON MONITORING SEE SECTION 7-7 ELEC. PENETR.

X-104A 12* 920'-10" 215' 12* 1 CONTROL ROD POSITION INDICATOR SEE SECTION 7-7 ELEC. PENETR.

X-32 10" 898'-9" s8* 1" 6 X-32(A-F) INSTRUMENT TO CV OR BCV SEE SECTION 2-2 X-104B 12* 919'-1" 218' 12* 1 CONTROL ROD POSITION INDICATOR SEE SECTION 7-7 ELEC. PENETR.

X-33 10" 898'-9" 65" 1* 6 X-33(A-D) INSTRUMENT TO CV OR BCV SEE SECTION 2-2 X-104C 12* 920'-10* 220' 12* 1 SPARE SEE SECTION 7-7, lYPE "A" TESTED X-33(E) IA TO MS-738AV NBl-563, NBl-564 (SEE NOTE 1) X-104D 12* 919'-5" 350' 12* 1 CONTROL ROD POSITION INDICATOR SEE SECTION 7-7 ELEC. PENETR.

X-33(F) IA TO NBl-736AV NBl-565, NBl-566 (SEE NOTE 1) X-104E 12* 920'-10* 355* 12* 1 CONTROL ROD POSITION INDICATOR SEE SECTION 7-7 ELEC. PENETR.

X-34 10" 911'-6" 260' 1" 6 X-34(A-D) INSTRUMENT TO CV OR BCV SEE SECTION 1-1 X-105A 12* 919'-5" 12' 12" 1 POWER SEE SECTION 6-6 ELEC. PENETR.

X-34(E-F) SPARE lYPE "A" TESTED X-105B 12* 920'-10" 17' 12* 1 SPARE SEE SECTION 6-6, lYPE "A" TESTED X-35A 1 1/2" 900'-11" 206' 3/8" 1 TIP SEE SECTION 1-1 DOUBLE 0-RING NMT-NVA-104A (SEE NOTE 2) X-105C 12* 919'-5" 20' 12* 1 SPARE SEE SECTION 6-6, lYPE "A" TESTED X-35B 1 1/2" 900'-11" 21 o* 3/8" 1 TIP SEE SECTION 1-1 DOUBLE 0-RING NMT-NVA-104B (SEE NOTE 2) X-105D 12" 920'-10" 347' 12" 1 POWER SEE SECTION 7-7 ELEC. PENETR.

X-35C 1 1/2" 900'-11* 214' 3/8" 1 TIP SEE SECTION 1-1 DOUBLE 0-RING NMT-NVA-104C (SEE NOTE 2) X-106 12* 919'-5" a* 12* 1 NEUTRON MONITORING SEE SECTION 7-7 ELEC. PENETR.

X-35D 1 1/2" 900'-11" 218' 3/8" 1 TIP SEE SECTION 1-1 DOUBLE 0-RING NMT-NVA-104D (SEE NOTE 2) SIP1 16" 961'-10 3/4" o* - 1 INSPECTION HATCH DOUBLE 0-RING X-35E 1 1/2" 900'-11* 222* 3/8" 1 TIP N, PURGE SEE SECTION 1-1 DOUBLE 0-RING NM-CV4, NM-CV2 (SEE NOTE 1) SJP2 16" 961'-10 3/4" 45' - 1 INSPECTION HATCH DOUBLE 0-RING SJP3 16" 961'-10 3/4" 90' - 1 INSPECTION HATCH DOUBLE 0-RING SIP4 16" 961'-10 3/4" 135' - 1 INSPECTION HATCH DOUBLE 0-RING SIPS 16" 961'-10 3/4" 180" - 1 INSPECTION HATCH DOUBLE 0-RJNG SJP6 16" 961'-10 3/4" 225' - 1 INSPECTION HATCH DOUBLE 0-RING SIP7 16" 961'-10 3/4" 270' - 1 INSPECTION HATCH DOUBLE 0-RING SIP8 16" 961'-10 3/4" 31 s* - 1 INSPECTION HATCH DOUBLE 0-RING NOTE:

1 . BOTH ISOLATION VALVES ARE OUTBOARD OF DRYWELL CONTAINMENT.

2. ONLY ONE ISOLATION VALVE EXISTS.
3. ALL PENETRATION LOCATIONS SHOWN IN THE SCHEDULE ARE APPROXIMATE.
4. COMPONENTS ARE SUBJECT TO TESTING UNDER 10CFR5O, APPENDIX J TYPE "B" REQUIREMENTS IF MAINTENANCE OR A MODIFICATION IS MADE.
5. IN-LINE MANUAL VALVES ARE NOT SUBJECT TO TYPE "c" TESTING.
6. INSTRUMENT PORTION IS AN EXTENSION OF CONTAINMENT.
7. CLOSED LOOP PROVIDES THE SECOND BARRIER.

AS BUILT

  • THIS DRAWING GENERATED BY NPPD 453243226 SIGNIFJCANT DRAWN I DATE NUMBER SPB 3/22/96

(/)

z GROUP 1 2 J

  • 5 6 a,
  • suRNS & ROE CHECKED I DATE a

ui

~ NO.

REVISIONS BY N.P.P.D.

REVISIONS DFT CKD APP DATE CONTAINMENT VESSEL JEH APPROVED 1/31/97 I DATE "a

~

N a

"' NOD N01 CR96-0160 <DCN 97-00951 UCR BINDER 22A (DCN 00-0645)

SPB DLR JEH TMB JRF KG 1-31-9 8/2/00 PEN ET RATION SCHEDULE JRF 1/31/97 a N02 PIR 2-21154 <DCN 99-03151 KG DLR RGA 8/16/01 "J 0 C:

SHEET 1A FILt.tED 4259 N03 EE 10-073 fDCN 11-0097\ KZ KZ DJB 2/9/12 REVISION N03 C

ci z [l

~