MONTHYEARML20217M3451999-10-20020 October 1999 Notice of Docketing of Matls License SNM-2506 Amend Application for Prairie Island ISFSI ML20206B5361999-04-22022 April 1999 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Oppportunity for Hearing.Amend Would Change Implementation Date for Relocation of Requirements in TS Sections 3.1.E & 5.1 ML20154G8681998-09-25025 September 1998 Notice of Consideration of Issuance of Amends to FOLs DPR-42 & DPR-60,proposed NSHC Determination & Opportunity for Hearing.Amends Would Change Design Basis of CWS Emergency Intake Line Flow Capacity ML20237D1601998-08-11011 August 1998 Notice of Consideration of Issuance of Amend to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Allow Design Mod to Existing ATWS AMSAC ML20217K5061998-04-24024 April 1998 Notice of Withdrawal of Application for Amend to Facility Operating License DPR-60 ML20217F9541998-03-24024 March 1998 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Update TS Heatup & Cooldown Rate Curves & Extend Reactor Fluence Limit from Current 20 EFPY ML20199J4731998-01-26026 January 1998 Notice of Consideration of Issuance of Amend to License DPR-42 & Proposed NSHC Determination & Opportunity for Hearing.Amend Would Initiate one-time Only Change for Pings Unit 1 Cycle 19 Allowing Use of Incore Detector Sys ML20211P1331997-10-0202 October 1997 Notice of Receipt of Petition for Directors Decision Under 10CFR2.206 ML20198J1251997-09-27027 September 1997 Notice of Directors Decision Concerning 970826 Petition Filed by CA Overland on Behalf of Florence Township,Mn Board of Supervisors,Per 10CFR2.206 ML20198J1361997-09-26026 September 1997 Notice of Issuance of Directors Decision 97-24 Re Petition Dtd 960826,filed by CA Overland on Behalf of Florence Township,Mn,Board of Supervisors,Under 10CFR2.206 ML20211E8201997-09-15015 September 1997 Notice of Partial Denial of Amends to Licenses DPR-42 & DPR-60 & Opportunity for Hearing.Nrc Concluded That Portion of Licensee Request Cannot Be Granted ML20216G4081997-08-29029 August 1997 Notice of Issuance of Directors Decision Under 10CFR2.206 Re 970528 Petition Filed by Prairie Island Indian Community Requesting That USNRC Take Action to Determine That NSP Violated Requirements of 10CFR72.122(i) ML20148P1191997-06-27027 June 1997 Notice of Receipt of Petition for Directors Decision Under 10CFR2.206,requesting That NRC Determine If NSP Violated Requirements of 10CFR72.122(1) Using Matls License SNM-2506 for Isfsi.Director Denied Petitioner Request for Action ML20138J2931997-02-0303 February 1997 Notice of Consideration of Issuance of Amends to FOLs DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Change Design Basis of CWS Emergency Intake Line Flow Capacity ML20133Q1481997-01-23023 January 1997 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amend Revises TSs Governing Cooling Water Sys DD-96-21, Notice of Issuance of Directors Decision DD-96-21 Under 10CFR2.206 Re Request That Prairie Island Units 1 & 2 Be Immediately Shut Down & Operating License Be Suspended Until Issues Raised in Petition Resolved1996-11-27027 November 1996 Notice of Issuance of Directors Decision DD-96-21 Under 10CFR2.206 Re Request That Prairie Island Units 1 & 2 Be Immediately Shut Down & Operating License Be Suspended Until Issues Raised in Petition Resolved ML20246P1031989-08-28028 August 1989 Notice of Issuance of Amends 89 & 82 to Licenses DPR-42 & DPR-60 ML20246N9761989-08-28028 August 1989 Notice of Issuance of Amends 90 & 83 to Licenses DPR-42 & DPR-60,respectively.Amends Revise Tech Specs by Permitting Irradiation of Fuel Assemblies W/Enrichment Up to 4.25 % W/O U-235 & Storage of Assemblies Prior to Loading in Reactors ML20248E7771989-08-28028 August 1989 Notice of Issuance of Amends 89 & 82 to Licenses DPR-42 & DPR-60,revising Effective Limitation of Existing RCS Heatup & Cooldown Curves from 15 to 20 EFPYs ML20245J8181989-06-0505 June 1989 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing on 890406 Request to Revise Tech Spec Fuel Enrichment Limits Permitted in Storage Pool ML20248C1681989-05-31031 May 1989 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Opportunity for Hearing on 890112 Request Re Pressure Temp Limits to Reflect Revised Commission Position on Radiation Effects on Embrittlement of Vessel ML20207J5791988-09-16016 September 1988 Notice of Issuance of Amends 84 & 77 to Licenses DPR-42 & DPR-60,respectively ML20148S5811988-04-0505 April 1988 Notice of Consideration of Issuance of Amend to License DPR-42 & DPR-60.Amend Changes Surveillance Test Frequency of Turbine Stop Valves in Tech Specs ML20203N0211986-09-16016 September 1986 Notice of Issuance of Environ Assessment & Finding of No Significant Impact Re 860221 Application for Amends to Licenses DPR-42 & DPR-60,changing Expiration Dates for Unit 1 to 130809 & Unit 2 to 141029.EIS Unwarranted ML20128Q7291983-07-0808 July 1983 Notice of Consideration of Issuance of Amends to Licenses DPR-24 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing Re Request to Change Limit of Core Local Heat Flux Ratio ML20071E2051983-02-23023 February 1983 Notice of Issuance & Availability of Amends 62 & 56 to Licenses DPR-42 & DPR-60,respectively ML20064H0351983-01-0404 January 1983 Notice of Issuance & Availability of Amends 60 & 54 to Licenses DPR-42 & DPR-60,respectively ML20066B4001982-10-18018 October 1982 Notice of Issuance & Availability of Amends 58 & 52 to Licenses DPR-42 & DPR-60,respectively ML20058F6301982-07-16016 July 1982 Notice of Issuance & Availability of Amends 56 & 50 to Licenses DPR-42 & DPR-60,respectively ML20054C8401982-03-0505 March 1982 Notice of Issuance & Availability of Amends 55 & 49 to Licenses DPR-42 & DPR-60,respectively ML20049J0701982-02-26026 February 1982 Notice of Issuance & Availability of Amends 54 & 48 to Licenses DPR-42 & DPR-60,respectively ML20040B3741981-12-30030 December 1981 Notice of Issuance & Availability of Amends 53 & 47 to Licenses DPR-42 & DPR-60,respectively ML20039B9691981-12-0404 December 1981 Notice of Issuance & Availability of Amends 52 & 46 to Licenses DPR-42 & DPR-60,respectively ML20010B7391981-07-28028 July 1981 Notice of Issuance & Availability of Amends 49 & 43 to Licenses DPR-42 & DPR-60,respectively ML19345H4641981-05-13013 May 1981 Notice of Issuance & Availability of Amends 48 & 42 to Licenses DPR-42 & DPR-60,respectively ML20008F3751981-03-0202 March 1981 Notice of Issuance & Availability of Amends 46 & 40 to Licenses DPR-42 & DPR-60,respectively ML19341D3991981-02-25025 February 1981 Notice of Issuance & Availability of Amends 45 & 39 to Licenses DPR-42 & DPR-60,respectively ML20003C4151981-02-13013 February 1981 Notice of Extension of Installation Date of Fire Pump Encl & Related Day Tank Curbing to 810601 ML19351F2511980-12-17017 December 1980 Notice of Issuance & Availability of Amends 44 & 38 to Licenses DPR-42 & DPR-60,respectively ML19345C3041980-11-14014 November 1980 Notice of Issuance & Availability of Amends 43 & 37 to Licenses DPR-42 & DPR-60,respectively ML19343A2531980-08-27027 August 1980 Notice of Issuance & Availability of Amends 42 & 36 to Licenses DPR-42 & DPR-60,respectively ML19322E6661980-02-29029 February 1980 Notice of Issuance & Availability of Amends 41 & 35 to License DPR-42 & DPR-60,respectively ML19248D4401979-08-0303 August 1979 Notice of Issuance & Availability of Amends 38 & 32 to Licenses DPR-42 & DPR-60,respectively ML19274F0761979-05-0101 May 1979 Notice of Issuance & Availability of Amends 36 & 30 to Licenses DPR-42 & DPR-60,respectively ML19273B2281979-03-14014 March 1979 Notice of Issuance & Availability of Amends 34 & 28 to Licenses DPR-42 & DPR-60 Respectively ML19274E4651979-03-0202 March 1979 Notice of Issuance & Availability of Amends 33 & 27 to Licenses DPR-42 & DPR-60,respectively ML20058A2891978-11-0909 November 1978 Notice of Proposed Issuance of Amend to Facil Oper Lic DPR-42 & DPR-60,rev Tech Spec Re Use of Exxon Fuel in Cycles 5 Thru 8 ML20058A2541978-11-0101 November 1978 Notice of Issuance of Amend 32 & 26 to Subj Facil Oper Lic 1999-04-22
[Table view] Category:TEXT-CODE OF FEDERAL REGULATIONS
MONTHYEARML20217M3451999-10-20020 October 1999 Notice of Docketing of Matls License SNM-2506 Amend Application for Prairie Island ISFSI ML20206B5361999-04-22022 April 1999 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Oppportunity for Hearing.Amend Would Change Implementation Date for Relocation of Requirements in TS Sections 3.1.E & 5.1 ML20154G8681998-09-25025 September 1998 Notice of Consideration of Issuance of Amends to FOLs DPR-42 & DPR-60,proposed NSHC Determination & Opportunity for Hearing.Amends Would Change Design Basis of CWS Emergency Intake Line Flow Capacity ML20237D1601998-08-11011 August 1998 Notice of Consideration of Issuance of Amend to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Allow Design Mod to Existing ATWS AMSAC ML20217K5061998-04-24024 April 1998 Notice of Withdrawal of Application for Amend to Facility Operating License DPR-60 ML20217F9541998-03-24024 March 1998 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Update TS Heatup & Cooldown Rate Curves & Extend Reactor Fluence Limit from Current 20 EFPY ML20199J4731998-01-26026 January 1998 Notice of Consideration of Issuance of Amend to License DPR-42 & Proposed NSHC Determination & Opportunity for Hearing.Amend Would Initiate one-time Only Change for Pings Unit 1 Cycle 19 Allowing Use of Incore Detector Sys ML20211P1331997-10-0202 October 1997 Notice of Receipt of Petition for Directors Decision Under 10CFR2.206 ML20198J1251997-09-27027 September 1997 Notice of Directors Decision Concerning 970826 Petition Filed by CA Overland on Behalf of Florence Township,Mn Board of Supervisors,Per 10CFR2.206 ML20198J1361997-09-26026 September 1997 Notice of Issuance of Directors Decision 97-24 Re Petition Dtd 960826,filed by CA Overland on Behalf of Florence Township,Mn,Board of Supervisors,Under 10CFR2.206 ML20211E8201997-09-15015 September 1997 Notice of Partial Denial of Amends to Licenses DPR-42 & DPR-60 & Opportunity for Hearing.Nrc Concluded That Portion of Licensee Request Cannot Be Granted ML20216G4081997-08-29029 August 1997 Notice of Issuance of Directors Decision Under 10CFR2.206 Re 970528 Petition Filed by Prairie Island Indian Community Requesting That USNRC Take Action to Determine That NSP Violated Requirements of 10CFR72.122(i) ML20148P1191997-06-27027 June 1997 Notice of Receipt of Petition for Directors Decision Under 10CFR2.206,requesting That NRC Determine If NSP Violated Requirements of 10CFR72.122(1) Using Matls License SNM-2506 for Isfsi.Director Denied Petitioner Request for Action ML20138J2931997-02-0303 February 1997 Notice of Consideration of Issuance of Amends to FOLs DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amends Would Change Design Basis of CWS Emergency Intake Line Flow Capacity ML20133Q1481997-01-23023 January 1997 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing.Amend Revises TSs Governing Cooling Water Sys DD-96-21, Notice of Issuance of Directors Decision DD-96-21 Under 10CFR2.206 Re Request That Prairie Island Units 1 & 2 Be Immediately Shut Down & Operating License Be Suspended Until Issues Raised in Petition Resolved1996-11-27027 November 1996 Notice of Issuance of Directors Decision DD-96-21 Under 10CFR2.206 Re Request That Prairie Island Units 1 & 2 Be Immediately Shut Down & Operating License Be Suspended Until Issues Raised in Petition Resolved ML20246P1031989-08-28028 August 1989 Notice of Issuance of Amends 89 & 82 to Licenses DPR-42 & DPR-60 ML20246N9761989-08-28028 August 1989 Notice of Issuance of Amends 90 & 83 to Licenses DPR-42 & DPR-60,respectively.Amends Revise Tech Specs by Permitting Irradiation of Fuel Assemblies W/Enrichment Up to 4.25 % W/O U-235 & Storage of Assemblies Prior to Loading in Reactors ML20248E7771989-08-28028 August 1989 Notice of Issuance of Amends 89 & 82 to Licenses DPR-42 & DPR-60,revising Effective Limitation of Existing RCS Heatup & Cooldown Curves from 15 to 20 EFPYs ML20245J8181989-06-0505 June 1989 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing on 890406 Request to Revise Tech Spec Fuel Enrichment Limits Permitted in Storage Pool ML20248C1681989-05-31031 May 1989 Notice of Consideration of Issuance of Amends to Licenses DPR-42 & DPR-60 & Opportunity for Hearing on 890112 Request Re Pressure Temp Limits to Reflect Revised Commission Position on Radiation Effects on Embrittlement of Vessel ML20207J5791988-09-16016 September 1988 Notice of Issuance of Amends 84 & 77 to Licenses DPR-42 & DPR-60,respectively ML20148S5811988-04-0505 April 1988 Notice of Consideration of Issuance of Amend to License DPR-42 & DPR-60.Amend Changes Surveillance Test Frequency of Turbine Stop Valves in Tech Specs ML20203N0211986-09-16016 September 1986 Notice of Issuance of Environ Assessment & Finding of No Significant Impact Re 860221 Application for Amends to Licenses DPR-42 & DPR-60,changing Expiration Dates for Unit 1 to 130809 & Unit 2 to 141029.EIS Unwarranted ML20128Q7291983-07-0808 July 1983 Notice of Consideration of Issuance of Amends to Licenses DPR-24 & DPR-60 & Proposed NSHC Determination & Opportunity for Hearing Re Request to Change Limit of Core Local Heat Flux Ratio ML20071E2051983-02-23023 February 1983 Notice of Issuance & Availability of Amends 62 & 56 to Licenses DPR-42 & DPR-60,respectively ML20064H0351983-01-0404 January 1983 Notice of Issuance & Availability of Amends 60 & 54 to Licenses DPR-42 & DPR-60,respectively ML20066B4001982-10-18018 October 1982 Notice of Issuance & Availability of Amends 58 & 52 to Licenses DPR-42 & DPR-60,respectively ML20058F6301982-07-16016 July 1982 Notice of Issuance & Availability of Amends 56 & 50 to Licenses DPR-42 & DPR-60,respectively ML20054C8401982-03-0505 March 1982 Notice of Issuance & Availability of Amends 55 & 49 to Licenses DPR-42 & DPR-60,respectively ML20049J0701982-02-26026 February 1982 Notice of Issuance & Availability of Amends 54 & 48 to Licenses DPR-42 & DPR-60,respectively ML20040B3741981-12-30030 December 1981 Notice of Issuance & Availability of Amends 53 & 47 to Licenses DPR-42 & DPR-60,respectively ML20039B9691981-12-0404 December 1981 Notice of Issuance & Availability of Amends 52 & 46 to Licenses DPR-42 & DPR-60,respectively ML20010B7391981-07-28028 July 1981 Notice of Issuance & Availability of Amends 49 & 43 to Licenses DPR-42 & DPR-60,respectively ML19345H4641981-05-13013 May 1981 Notice of Issuance & Availability of Amends 48 & 42 to Licenses DPR-42 & DPR-60,respectively ML20008F3751981-03-0202 March 1981 Notice of Issuance & Availability of Amends 46 & 40 to Licenses DPR-42 & DPR-60,respectively ML19341D3991981-02-25025 February 1981 Notice of Issuance & Availability of Amends 45 & 39 to Licenses DPR-42 & DPR-60,respectively ML20003C4151981-02-13013 February 1981 Notice of Extension of Installation Date of Fire Pump Encl & Related Day Tank Curbing to 810601 ML19351F2511980-12-17017 December 1980 Notice of Issuance & Availability of Amends 44 & 38 to Licenses DPR-42 & DPR-60,respectively ML19345C3041980-11-14014 November 1980 Notice of Issuance & Availability of Amends 43 & 37 to Licenses DPR-42 & DPR-60,respectively ML19343A2531980-08-27027 August 1980 Notice of Issuance & Availability of Amends 42 & 36 to Licenses DPR-42 & DPR-60,respectively ML19322E6661980-02-29029 February 1980 Notice of Issuance & Availability of Amends 41 & 35 to License DPR-42 & DPR-60,respectively ML19248D4401979-08-0303 August 1979 Notice of Issuance & Availability of Amends 38 & 32 to Licenses DPR-42 & DPR-60,respectively ML19274F0761979-05-0101 May 1979 Notice of Issuance & Availability of Amends 36 & 30 to Licenses DPR-42 & DPR-60,respectively ML19273B2281979-03-14014 March 1979 Notice of Issuance & Availability of Amends 34 & 28 to Licenses DPR-42 & DPR-60 Respectively ML19274E4651979-03-0202 March 1979 Notice of Issuance & Availability of Amends 33 & 27 to Licenses DPR-42 & DPR-60,respectively ML20058A2891978-11-0909 November 1978 Notice of Proposed Issuance of Amend to Facil Oper Lic DPR-42 & DPR-60,rev Tech Spec Re Use of Exxon Fuel in Cycles 5 Thru 8 ML20058A2541978-11-0101 November 1978 Notice of Issuance of Amend 32 & 26 to Subj Facil Oper Lic 1999-04-22
[Table view] |
Text
-_
7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY DOCKETS NOS. 50-282 AND 50-306 NOTICE OF CONSIDERATION OF ISSUANCE OF AMENDMENTS TO FACILITY OPERATING LICENSES AND OPPORTUNITY FOR HEARING The United States Nuclear Regulatory Commission (the Commission) is considering issuance of amendments to Faciiity Operating License Nos. DPR-42 and DPR-60, issued to the Northern States Power Company (the licensee), for operation of the Prairie Island Nuclear Generating Plant, Units Nos. I and 2, located in Goodhue County, Minnesota.
In accordance with the licensee's application for amendments dated January 12, 1989, the amendments would change the pressure temperature limits given in the specification Figures TS 3.1-1 and TS 3.1-2 and the specifications TS 3.1.B and TS 3.1.G to reflect the revised Commission position on the radiation effects on the embrittlement of the reactor vessel materials.
The methods described in Revision 2 of Regulatory Guide 1.99 were used by the licensee in preparing the amendment request.
Prior to issuance of the proposed license amendments, the Commission will have made findings required by the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations.
ByJuly 10, 1989, the licensee may file a request for a hearing with respect to issuance of the amendments to the subject facility operating licenses and any person whose interest may be affected by this proceeding and who wishes 8906090288 890531 PDR ADOCK 0500 2
P D
. S to participate as a party in the proceeding must file a written request for hearing and a petition for leave to intervene.
Requests for a hearing and petitions for leave to intervene shall be filed in accordance with the Commission's " Rules of Practice for Domestic Licensing Proceedings" in 10 CFR Part 2.
If a request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Commission or by the Chairman of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition, and the Secretary or the designated Atomic Safety and Licensing Board will issue a notice of hearing or an appropriate order.
l As required by 10 CFR 2.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding and how that interest may be affected by the results cf the proceeding. The petition should specifically explain the reasons why intervention should be permitted with particular reference to the following factors:
(1) the nature of the petitioner's right under the Act to be made a party to the proceeding; (2) the nature and extent of the petitioner's property, financial, or other interest in the proceeding; and (3) the possible effect of any order which may be entered in the proceeding on the petitioner's interest. The petition should also identify the specific aspect (s) of the subject matter of the proceeding as to which petitioner wishes to intervene. Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition without requesting leave of the Board up to fifteen (15) days prior to the first pre-hearing conference scheduled in the proceeding, but such an amended petition must satisfy the specificity requirements described above.
Not later than fifteen (15) days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene, which must include a list of the contentions that are sought to be litigated in the matter and the bases for each contention set forth with reason-able specificity. Contentions shall be limited to matters within the scope of the amendments under consideration. A petitioner who fails to file such a supple-ment which satisfies these requirements with respect to at least one contention will not be permitted to participate as a party.
Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene, and have the opportunity to participate fully in the condu:t of the hearing, including the opportunity to present evidence and cross-examine witnesses.
A request for a hearing or a petition for leave to intervene must be filed with the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Fashington, DC 20555, Attention: Docketing and Service Branch, or may be delivered to the Commission's Public Document Room, 2120 L Street, NW.,
Washington, DC, by the above date. Where petitions are filed during the last ten (10) days of the notice period, it is requested that the petitioner promptly so inform the Commission by a toll-free telephone call to Western Union at 1-800-325-6000 (in Missouri 1-800-342-6700). The Western Union operator should be given Datagram Identification Number 3737 and the following message addressed to Lawrence A. Yandell (petitioner's name and telephone number);
(date petition was mailed); (plant name); and (publication date and page number of this FEDERAL REGISTER notice). A copy of the petition should also be sent to the Office of the General Counsel, U.S. Nuclear Regulatory Commission.
-____-_-__--__--__-__a
i I' s 1
~
Washington, DC 20555, and to Jay Silberg, Esq., Shaw, Pittman, Potts and Trowbridge,'2300 N Street, NW., Washington, DC 20037.
Nontimely filings of petitions for leave to intervene, amended petitions, supplemental petitions and/or requests for hearing will not be entertained absent a determination by the Commission, the presiding officer or the presiding Atomic Safety and Licensing Board that the petition and/or request should be granted based upon a balancing of the factors specified in 10 CFR 2.714(a)(1)(i)-(v) and 2.714(d).
If a request for hearing is received, the Commission's staff may issue the amendments after it completes its technical review and prior to the completion of any required hearing if it publishes a further notice for public comment of its proposed finding of no significant hazards consideration in accordance with 10 CFR 50.91 and 50.92.
For.furthcr details with respect to this action, see the application for amendments dated January 12, 1989, which is available for public inspection at the Commission's Public Document Room, 2120 L Street, NW., Washington, DC 20555, and at the Minneapolis Public Library, Technology and Science Department, 300 Nicollet Mall, Minneapolis, Minnesota 55401 Dated at Rockville, Maryland, this 31st day ofMay 1989.
FOR THE NUCLEAR REGULATORY COMMISSION Jo i J.
tefan, Acti Director P
ect Direc orate
-1 visio eactor rojects - III, IV, V l
& Special Projects Office of Nuclear Reactor Regulation L