_ i__________________________________________--___----;

U.S. NUCLEAR REEULATORY COMMISSION

. Nnc Pons s1s isam

- CERTIFICATE OF COMPLIANCE E

to c m 1 FOR RADIOACTIVE MATERIALS PACKAGES 1 e CEntlPICATE NU b REVISION NU ER

c. PACKAGE TFC i UMBhR d.PAGE NU BER
e. TOTAL NUM8 R PAGES C

't

'7 PREAMBd a Tni. e.nificat. i. i..u.o io c.nity inai in. pacxasing and coni.nt. o..cne.o in item s e.io.. m..ts in appoc oi..af.iy ii noaro...t fortn in Titi. io. coo.

t of Feo.ral Regulations, Part 71. " Packaging and Transportation of Raoioactiv. Material" C

. o Tn. conificai. oo.. noi r.n.

in. con.igno, erom compnanc. witn any r.que.m.nt of ine r.guianon of in. u s o.oartm.ni of Transportation or otner appocabi. r.guiatory so.nc. inciuoing in. governm.ni of any country inrouan or into wnien in. package wiii b transport.o.

{

E

(

."$s'EE*JJ .'*,8fff.,, '"* ** ' ^ **" ^"*"*'*c"'TTE Allfo*EEC$od$$Ei oEN^P CATlON' L

Combustion Engineering, Inc.

Combustion Engineering, Inc. application L

C t

1000 Prospect Hill Road dated January 11, 1960, as supplemented.

Windsor, CT 06095

[

U#U

\\. ooCxET NUuBER

(

4 CoNolTIONS I

l l

inis c rtificate is conottional upon fulfilnno tne requirements of 10 CFR Part 71, as appncable, and tn conditior a specified below.

r ls b

l fi la)

Pack, aging

[

I (1) Model No.:

CE-250-2 i

f (2) Description L

The packaging consists of a 16-gauge steel containment vessel, 11-

[

'5/8 inches ID by 57-1/4 inches icng with a bolted and gasketed top e

l 1

flange closure and steel welded bottom plate.

The containment vessel E

is centered and supported in a 22-1/2-inch ID by 68-3/8-inch long, b

16-gauge steel drum by twelve (12), 1/4-inch diameter spring steel rods welded to the containment vessel at the top flange and the bottom E

of the vessel. The void space between the containmer.t vessel and b

outer container is filled with vermiculite.

[

[

1

[g Closure of the containment vessel is maintained by)a gasket (either silicone rubber or asbestos and rubber) and six (6, 1/2-inch hex head bolts and nuts.

The cuter container closure is made with a 12-gauge t

bolt locking ring with drop forged lugs, one of which is threaded, b

having a 5/8-inch diameter bolt and lock nut.

E C

The gross weight of the packaging and contents is approximately 575 pounds.

C L

L I

B711040010 871030 b

PDR ADOCK 07109022 C

j C

pop I

1

)

i

. CCNOITl:NS (continuid)

E E

~

l Page'2 - Certificate No. 9022-Revision No. 11 - Docket No. 71-9022 E

E i

$l (3)

Drawing The packaging is constructed in accordance with Combustion Engineering. !

Company, Inc. Drawing No. NFM-E-Z2175, Revision 03.

jg E

(b) Contents i

i E

(1) Type and form of material 4

1 Dry uranium oxide pellets and powder enriched to a maximum 4.1 w/o in g

the U-235-isotope. The maxi. mum H/U atomic ratio, considering all E

sources of hydrogenous material within the containment vessel'shall l

not exceed 2.26.

(2) Maximum quantity of material per package-l The total contents not to exceed 300 pounds, with the U-235 content 5

not to exceed 4.5 kilograms. The contents shall be contained within E

sealed steel containers with a maximum cross sectional area of 73.2 I

N square inches.

(c)

Fissile Class

.II t

Minimum transport index to be shown on label 0.6 Rev. 03) must be made of silicone rubber, or. an Anchor Packing Company gasket I g

l 6.

The containment vessel closure gasket (Item No. 12, Drawing No. NFM-E-Z2175, g

" Target" or "425."

7.

Spacers and prcduct containers shall be used to provide a snug axial fit of the 5

product containers within the containment vessel.

l 18.

The package authorized by this certificate is hereby approved for use under the gereral license provisions of 10 CFR 671.12.

E 9.

Expiration date:

June 30, 1990.

E i

E ii a

R E

E E

N E

I s

l l

--srarmnumrmrmrersmNarsturenenmemmmmm--mmmenc-mmmme.cemmm,mzip

~

conosinons (continues >

Page 3 - Certificate No. 9022-Revision No. 11 - Docket No. 71-9022 I

I I

p' d

REFERENCES E

l l

g Combustion Engineering, Inc. application dateo January 11, 1980, p

i W

I Supplement dated:

June 6, 1980 and September 21, 1987.

I y

4 l

Exxon Nuclear Company supplement dated:

May 13, 1981.

l l

FOR THE U.S. NUCLEAR REGULATORY COMMISSION E

l l

DA l l Charles E. MacDonald, Chief E

E:

l Transportation. Franch g

g Division of Safeguards and W

Transportation, NMSS Date:

OCT 3 n ma?

W li id i

n E

'd E

E E

E E

I I

I H

E I

E ki k

N

== ='amammaraswaaum.wwiec my

, _ ; - ;o

  • p r m,,if v

i

UNITED $TATES f.7 ',,q 'g NUCLEAR REGULATORY COMMISSION 1-[

f 2:

WASHINGTON, D. C. 20655 h

C.4 Y 0 4*4 #

i I

Transportation Branch Approval Record.

Model'No. CE-250-2 Package.

Docket No. 71-9022 Revision f!o. 11

By application dated September 21, 1987, Combustion Engineering, Inc.

requested an amendment to Certificate of Compliance No. 9022.

The amendment was submitted for-incorporation into the Certificate of:

Compliance. revised package drawing number NFM-E-Z2175~ revision 03.

y I

' Drawing No. NFM-E-Z2175 was revised to: correct dimensional errors.

The above changes do not effect the ability of the package to meet the requirements of 10 CFR Part 71.

Charles E.

acDonald,' Chief Transportation. Branch Division of Safeguards and Transportation,;NMSS 80 W Date:

l 1

i j

i 1

i

_ _ _ _ _ _ _ - _ _ _ _ _