ML19338F733
| ML19338F733 | |
| Person / Time | |
|---|---|
| Site: | 07109022 |
| Issue date: | 10/14/1980 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19338F732 | List: |
| References | |
| NUDOCS 8010270122 | |
| Download: ML19338F733 (3) | |
Text
o 1
V Farm NFC 618 U.S. NUCLE AR AEGULATCRY CC',".*t!$1CN in 73 CERTIFICATE OF COMPT.!ANCE For Aacioactive Materials Packages 1 (al Certificate Number 1.!b) Rwision No.
1.fcl Pacxage Identification No.
1.(d) Pages No. 1.te) Total No. Pages 9022 5
USA /9022/AF 1
3
- 3. PAEAMBLE 2.ta)
This certificate is essa.ed to satisfy sections 173.393a.173.'94.173.395, and 173.*S6 of the oecartrrent of Transportatioa Hazarcous Materiais Regulations 149 CFR 170189 and 14 CFR 103) and Sections 146-19-1Ca and 146-19-100 of tne escartrnent of Transoortation oangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents desenbed in item 5 betow, mms the safety standaros set forth in Subcart C of Title 10. Cace of Federas Aequiatens, Part 71. " Packaging of Radioactive Maurnals for Transport and Transoortaticn of Aacicactive Matenal Uncer i
Certaan Concitions.
2.fc)
This certificate does not relieve the consignor from comodiance with any recuirerr.ent of the regulations of the U.S oecartmerit of Transportation or other acolicaole regulatory agencies, inducing the government of any country tnrougn or into unich the osckage wall be transoorted.
j
- 3. ~his certificate is issued on the easis of a safety analysis report of the pacxage cesq;n or aposication-3.lal.Precated oy t'llame and sodress):
3.(b)
Title and <sentification of recort or acotication:
Cocoustion Engineering Co., Inc.
Combustion Engineering, Inc. application 10C0 Prospect Hill Road dated January 11, 1980', as supple'mented.
Windsor, CT 06095 3.(c) oocket w.
71_902u,,
4 CONolTICNS This certificate is conditional upon th
'illing of the reovirements of Suenart o of 10 CFR 71, as acclicaele, and the conditions specified in item 5 tetow.
- 5. Cescnotion of Packaging and Aumonzeo Cantents. Model Numcor Fissile C: ass, otner Conditions, and
References:
(a) Packaging (1) Model No.:
CE-250-2 (2) Description The packaging consists of a 16 gauge steel containment vessel, 11-5/8 inches ID by 57-1/4 inches long with a bolted and gasketed top flange closure and steel welded bottom plate.
The containment vessel is centered and supported in a 22-1/2 inch ID by 68-3/8-inch long, 16 gauge steel drum by twelve (12),1/4-inch diameter spring steel rods welded to the containment vessel at the top flange. and the bottom of the vessel.
The void space between the containment vessel and outer container is filled with vermiculite.
Closure of the containment vessel is maintained by a rubber gasket and six (6), 1/2-inch hex head bolts and nuts.
The outer container closure is
~
made with a 12 gauge bolt locking ring with drop f.orged lugs, one of which is threaded, having a 5/8-inch diameter bolt and lock nut.
The gross weight of the packaging and contents is approximately 575 pounds.
8010270/JA
\\
- 1;+ 2 - Cs.ificate No. 9022 - Revision No. 5 - Occhet No. 71-9022 (3) Drawing The packaging is constructed in accordance with Combustion Engineering Company, Inc. Drawing No. NFM-E-Z2175, Revision 00.
(b) Contents (1) Type,and form of material Ory uranium oxide pellets and powder enriched to a maximum 4.1 w/o in the U-235 isotope.
The maximum H/U atomic ratio, considering all sources of hydrogenous material within the containment vessel shall not exceed 2.26.
(2) Maximum quantity of material per package The total contents not to exceed 300 pounds, with the U-235 content not to exceed 4.5 kilograms.
The contents shall be contained within sealed stainless steel containers with a maximum cross sectional area of 73.2 scuare inches.
(c) Fissile Class II t
Minimum transport index to be shown on label 0.6 6.
Spacers and product containers shall be used to provide a snug axial fit of the precuct containers within the containment vessel.
7.
Attachment of handle (Item 18, Drawing No. NFM-EZ2175) to outer lid is not authorized.
8.
Alternate closure system shown in Figure 1 of Exxon Nuclear Company, Inc. letter cated Au;ast 14, 1980 is authorized.
3.
The package authorized by this certificate is hereby approved for use under the generai license provisions of 10 CFR 971.12(b).
10.
Expiration date:
June 30, 1985.
7---
4
- i;i 3 -
- artificate No. 9022 - Revision fio. 5 - Occket too. 71-9022 5
REFERENCES Combustion Engineering, Inc. application dated January 11, 1980.
Supplement dated:
June 6, 1980.
i FOR THE U.S. NUCLEAR REGULATORY COMMISSION M db j
Charles E. MacDonald, Chief Transportation Certification Branch i
Division of Fuel Cycle and Material Safety OCT 141980 Cate:
9 9
e
/
4 a
4 e.-e
- + - -
4 e
,,s a,
.,,w,-
y 3---r.-4-,--w- - -9
,.y
+