Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION U

CERTIFICATE OF COMPUANCE 10 CFR 71 For Radioec'.sve Materieds Packages 1.(a) Certificate Nurnber 1.(b) Revision No.

1.le) Pschaos identification No.

1.(d) Pages No. 1.(e) Total No. Pages 9022 2

USA /9022/AF 1

3

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394.173.395, and 173.396 of the Department of Transportaten Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10e and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amendad.

2.(b)

The packaging and contents descnbod in item 5 below, meets the safety standards set forth in Suboart C of Title 10. Code of Federal Regulations, Part 71. " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Cartain Conditions.'"

2.(c)

This csrtificate does not relieve the consagnor from compliance with any razuirement of the regulations of the U.S. Decertrnent of Transportation or other applicable reguaatory agencass including the gownment of any country through or into which the psckage will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package desagn or application-3.(a)

Propered by (Name and address #

3.tb)

Title and identification of report or application:

Combustion Engineering, Inc.

Application by letter dated July 12, 1974.

1000 Prospect Hill Road Windsor, Connecticut 06095 3.(c)

Occket No. 71-9022

4. CCNDITICNS Th6 certificate is conditional upon the fulfilling of the requirements of Subport D cf 10 CFR 71 as applicabla, and the conditions specified in item 5 below.
5. Descnotion of P3csaging and Authorized Contents. Model Nurrcer. Fissale Class. Other Conditions, and

References:

(a) Packaging (1) Model No. : CE-250-2 (2) Description The packaging consists of a 16-gauge steel inner container,11-5/8 inches ID by 57-1/4 inches long with a bolted and gasketed top flange closure and steel welded bottom plate. The inner container is centered and supported in a 22-1/2 inch ID by a minimum of 68-3/4 inches long, 16-guage stcel drum by 1/4 inch diameter spring steel rods and ver-miculite. The weight of the package is approximately 575 pounds when loaded and is constructed in accordance with Combustion Engineering Company Drawing No. NPM-E-3471.

(b) Contents (1) Type and form of material (i) Dr:* uranium oxide pellets and powder enriched to a maximum 4.0 w/o in the U-235 isotope.

The maximum H/U atomic ratio, f

considering all sources of hydrogenous material within the inner container shall not exceed 1.13.

n5'2-791002 0 v

?-

ic 7

e LVm v

~

'~

.:.~,----

Page 2 - Certificate No. 9022 - Revision No. 2 - Docket No. 71-9022 5.

(b)

(1) Contents (continued)

(ii) Uranium oxide enriched to a maximum 3.5 w/o in the U-235 isotope. Chemically-bound or physically-bound water in mixtures is pennitted. Slips or slurries that exhibit a visually discernible liquid second phase are prohibited.

(2) Maximum quantity of material per package (i) For the contents described in 5(b)(1)(1):

The total contents not to exceed 250 pounds, with the U-235 content not to exceed 2.0 kilograms. The contents may be contained within sealed steel or Fiberpak product containers.

(ii) For the contents described in 5(b)(1)(ii):

Total contents not to exceed 250 pounds, with the U-235 content not to exceed 2.95 kg. The contents shall be contained within two (2) 9.75 inch diameter by 12 inch high sealed stainless steel cans.

(c) Fissile Class II and III (1) Minimum transport index to be shown on label for Fissile Class II:

(i) For the Contents described in 5(b)(1)(1) and limited in 5(b)(2)(1):

0.6 (ii) For the Contents described in5(b)(1)(ii)andlimited in 5(b)(2)(ii):

2.0 (2) Maximum number of packages pe:-

shipment per Fissile Class III:

(i) For the Contents described in 5(b)(1)(i) and limited in 5(b)(2)(1):

200 (ii) For the Contents described in 5(b)(1)(ii) and limited in 5(b)(2)(ii):

56 yy

} v^ u/

m

-amow

Page 3 - Certificate No. 9022 - Revision No. 2 - Docket No. 71-9022 6.

Spacers and product containers shall be used to provide a snug axial fit of the product containers within the inner container.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

8.

Expiration date: January 31, 1980.

REFERENCES Combustion En'ineering, Inc. application dated July 12, 1974, requesting approval to deliver special nuclear material to a carrier for transport in the.% del No. CE-250-2 packaging.

Supplement dated:

February 20, 1976.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION M[

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and.%terial Safety SEP 141979 Date:

IcJL a

_