ML20236M159

From kanterella
Jump to navigation Jump to search
Informs of Concern Brought to Attention by K Battige Re UT Near Field Effects.Informs That Structural Weld Exam Technique,Using 10Mhz,.5 Inch Diameter Transducer,Would Produce Near Field Effect of 2.69
ML20236M159
Person / Time
Issue date: 03/02/1998
From: Howe A
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Doctor S
Battelle Memorial Institute, PACIFIC NORTHWEST NATION
Shared Package
ML20236K829 List:
References
FOIA-98-188 NUDOCS 9807130320
Download: ML20236M159 (2)


Text

_ _.

.a i!;;

From:

Allen Howe, ANr).IJ To:

Intemet:pn!. gov:sr_ doctor, intemet:inel. gov:mta2...

Date:

3/2/98 4:10pm

Subject:

UT issues - Phone Call Ken Battige brought a concem to my attention regarding the UT 'near field' effects. Specifically in mirroring a comment made by someone (I can't remember who) during our intamal planning discussions last week, the structural-lid weld examination technique, using a 10Mhz,0.5 in.

diameter transducer, would produce a near field effect of - 2.69". The depth of the weld volume examined is well within that range. Therefore we ask "Can an examination well within the near-field be valid?" We need to discuss this potential inspection issue and decide if we need to discuss it with the Owners Group before our site visit. I propose a call at 1:00 pm on Tuesday March 3. Please reply as to the acceptability of this time. We will call you. In addition, if there are any other issues that concem you please be ready to discuss them.

Thanks-Allen 00:

TWD2.TWPO.DAJ1 i

1 l

l t

9907130320 900630 PDR FOIA it (g M'"!**-,?

i

O Mall Envelope Info:

(34FB2042.A46 : 17 : 42080)

Subject:

UT lssues - Phone Call Creation Date:

3/2/98 4:10pm From:

Allen Howe Created By:

WND1.WNP7:AGH1 L

Recipients Action Date & Time Post Office intemet mta2 Post Office intemet sr_ doctor Post Office TWD2.TWP0 DAJ1 CC (Deborah Jackson)

Post Office WND1.WNP7 AGH1 (Allen Hows)

CKB1 (Charles (Ken) Battige)

Domain. Post Office Delivered Route intemet Pending intemet:inel. gov Intemet Pending intemet:pnl. gov TWD2.TWPO Pending TWD2.TWP0 WND1.WNP7 Pending WND1.WNP7 Files Size Date & Time MESSAGE 867 03/02/98 04:10pm View 4109 03/02/D811:10am Options Auto Delete:

No Expiration Date:

None Notify Recipients:

No Priority:

Normal Reply Requested:

No Return Notification::

None Concealed

Subject:

No Security:

Normal To Be Delivered:

Immediate Status Tracking:

AllInformation I

l

- - _ _ _ _ _ _.