Proposed Tech Specs Deleting Unit 1 License Condition 2.C.(30)(a) in Entirety
ML20217J298
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 03/24/1998
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20217J278 List:
References
NUDOCS 9804060260
Download: ML20217J298 (3)


Text

'

s PROPOSED AMENDMENTS TO THE LICENSE / TECHNICAL SPECIFICATIONS NPF-11 NPF-18 11 6-13 replace Figure 6.1-3 6-13 replace Figure 6.1-3 with insert A with insert A

'\

9804060260 980324 PDR ADOCK 05000373 P PDR ,,.

Inc rt A

' FIGURE 6.1-3 o

MINIMUM SHIFT CREW COMPOSITION (a)(c)

. POSITIONW MINIMUM CREW NUMBER EACH UNIT IN ONE UNIT IN CONDITION 1,2, EACH UNIT IN CONDITION 4 CONDITION 1,2, OR 3 OR 3, AND ONE UNIT IN OR 5 OR DEFUELED CONDITION 4 OR 5 OR DEFUELED SM 1 1 1 SRO 1 1 None RO 3 3 2 AO 3 3 3 STA(d) 1 1 None l

l (a) This table reflects the total requirements for shift staffing of both units.

With the exception of the Shift Manager, the shift crew composition may be one less than the minimum requiremente of Figure 6.1-3 for not more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to accommodate unexpected absence of on-duty shift crew members,

( provided immediate action le taken to restore the shift crew composition to within the minimum requirements of Figure 6.13. This proviolon does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.

(b) Table Notation:

SM Shift Manager with a Senior Reactor Operator license for each unit whose reactor contains fuel.

SRO Individual with a Senior Reactor Operator license for each unit whose reactor contains fuel.

During COAE ALTERATIONS on either unit a licensed SRO or licensed SRO limited to fuel handling, who has no other concurrent responsibilities, must be present to observe and directly supervlee this operation.

RO An Individual with a Reactor Operator license or a Senior Reactor Operator license for unit assigned. At least one RO shall be assigned to each unit whose reactor contains fuel. Individuals acting as relief operators shall hold a license for both units. Otherwise, for each unit, provide a relief operator who holds a license for the unit assigned.

AO At least one auxiliary operator shall be assigned to each unit whose reactor contains fuel.

STA Shift Technical Advisor.

(c) While either unit le in CONDITION 1,2, or 3, an Individual with a valid SRO licones shall be designated to assume the control room command function. With both Units in CONDITION 4 or 5, en Individual with a valid SRO or RO license shall be designated to assume the control room command function.

(d) The STA pooltion shall be filled by an Individual who meets the qualifications specified by the Commisolon Policy Statement on Engineering Expertise on Shift.

i 1

i

1 -

l CHANGE

SUMMARY

l .

l Technical Description Specification item Number Chance Description Unit 1 License 1 Delete the License Condition in its entirety Condition 2.C.(30)(a)

Figure 6.1-3 1 Superseded by the proposed Figure.

l l

l l