_

.-____.-m 9 473

. X244 ALL Document Control Desk Director of Nuclear Reactor Regulation

, U.S. Nuclear Regulatory Commission I

-. Mail Siation Pl 137 i

Washington, DC 20555 4

April 2,1997 i

v Attached is a revision to the Offsite Dose Calculation Manual, LaSalle Annex, Chapter 11. Please update your manual as follows:

Remove:

i

}

LaSalle Chapter 11, Revision 1.8 jand:

1 i

f LaSalle Chapter i1, Revision 1.9 4

Please sign below indicating your manual has been updated and that your controlled copy number is correct.

4i(

{'

j-Name Date.

I 1

l Retum to :

l' l

Comed l

Cer. tral Files 1400 Opus Place,4th Floor 1

Downers Grove,IL 60515 2

- or -

l Central Files

)

4th Floor O

Downers Grove 210037 j

9704210118 970331 I

PDR ADOCK 050003 3 i

hhhhh,@

f Revision 1.9 March 1997 CHAPTER 11 l0 LaSalle Annex Index Revision 1.9 4

1 i

1 i

E i

e d

O O

11-i

LASALLE Ravision 1.9 March 199'/

~

b CHAPTER 11 O'

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM TABLE OF CONTENTS CHAPTER ILILE EAGE j

11 Radiological Environmental Monitoring Program 11-1 LIST OF TABLES NUMBER IIILE EAGE 11-1 Radiological Environmental Monitoring Program 11-2 LIST OF FIGURES NUMBER IIILE EAGE O

11-1 Fixed Air Sampling Sites and Outer Ring TLD Locations 11-9 11-2 inner Ring TLD Locations 11-10 11-3 Ingestion and Waterborne Exposure Pathway Sample Locations 11-11 i

O 11-il 1

4 LASALLE Ravision 1.9 March 1997 CHAPTER 11 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM i

i The Radiological Environmental Monitoring Program for the environs around LaSalle Station is given in J

Table 11-1.

1 i.

l Figures 11-1 through 11-3 show sampling and monitoring locations.

t 4

i i

1 4

I i

9 i

4 4

i V i

s 1

i 3

1 i

i I

I i

I f

i l

l 1

?

i i

11-1

=

]

4

LASALLE Revision 1.9 March 1997 Table 11-1 Radiological Environmental Monitoring Program i

i i

Exposure Pathway e

i Sampling or i

Type and Frequency and/or Samole l

Samole or Monitorino Location l

Collection Freauencv l

of Analysis i

e i

_______________p_________________________________p________________p_________________.

1. Airbome i

l Continuous sampler i Radiciodine Canisters:

operation with particulate i Badinirviine and la. Indicators-Near Field l sample collection weekly. l l-131 analysis biweekly on Particulates i or more frequently if a near field and control l

L-01, Nearsite No.1,0.5 mi NNW (0.8 km R) l required by dust loading, l samples'.

i L-03, Onsite No. 3,0.2 mi ENE (0.3 km D) i and radioiodine canister i

L-05, Onsite No. 5, 0.3 mi ESE (0.5 km F) l collection biweekly l Particulate Samoler s

i L-06, Nearsite No. 6,0.4 mi WSW (0.6 km M) a l

l l Gross beta analysis l

,e following weekly filter i

e i change and gamma l

l l isotopic analysis' quarterly.

i e

i on composite filters by l

l l location on near field and i control samples.'

i i

i i

e i

e i

i lb. Indicators-Far Field l

l e

i I

L-04, Rte 170,3.2 mi E (5.1 km E)'

l L-07, Seneca, 5.2 mi NNE (8.4 km B) l l

i L-08, Marseilles,6.0 mi NNW (9.7 km R) i i

l L-11, Ransom,6.0 mi S (9.7 km J) l l

I i

i i

e i

e i

8 c.

Controls l

l l

L-10, Streator,13.5 mi SW (21.7 km L) l l

6 9

6' O

q

%) ~

SALLE Revision 1.9

  • March 1997 Table 11-1 (Cont'd)

Radiological Environmental Monitoring Program

~

~

i i

i Exposure Pathway l Samole or Monitorino Location l Sampling or l Type and Frequency and/or Sample C

i ollection Frecuency i of Analysis i

i 4

i

_______________p_________________________________p________________p_________________.

2.

Direct R=^=6nn i a. Indicators-inner Ring i Quarterly i Gamma dose on each TLD l

L-101-1, 0.5 mi N (0.8 km A) l l quarterly.

8 L-101-2, 0.5 mi N (0.8 km A) l l

L-102-1, 0.6 mi NNE (1.0 km B).

i i

l L-102-2, 0.6 mi NNE (1.0 km B) l l

l L-103-1, 0.7 mi NE (1.I km C) i i

l L-103-2, 0.7 mi NE (1.1 km C) l l

L-104-1, 0.8 mi ENE (1.3 km D) i i

l L-104-2, 0.8 mi ENE (1.3 km D) l l

t L-105-1, 0.7 mi E (1.1 km E) e i

L-105-2, 0.7 mi E (1.1 km E) l l

l L-106-1, 1.4 mi ESE (2.2 km F) l l

e L-106-2, 1.4 mi ESE (2.2 km F) i i

l L-107-1, 0.8 mi SE (1.3 km G) l l

8 L-107-2, 0.8 mi SE (1.3 km G) i l

L-108-1, 0.5 mi SSE (0.8 km H) l l

8 L-108-2, 0.5 mi SSE (0.8 km H) 8 8

l L-109-1, 0.6 mi S (1.0 km J) l l

l L-109-2, 0.6 mi S (1.0 km J) l l

i L-110-1, 0.6 mi SSW (1.0 km K) 8 i

l L-110-2, 0.6 mi SSW (1.0 km K) l l

L-111b-1, 0.8 mi SW (1.3 km L) a l

L-111b-2, 0.8 mi SW (1.3 km L) l l

8 L-112-1, 0.9 mi WSW (1.4 km M) i 8

l L-112-2, 0.9 mi WSW (1.4 km M) l l

l L-113a-1, 0.8 mi W (1.3 km N) i i

l L-113a-2, 0.8 mi W (1.3 km N) l l

l L-114-1, 0.9 mi WNW (1.4 km P) l l

L-114-2, 0.9 mi WNW (1.4 km P) e i

l L-115-1, 0.7 mi NW (1.1 km Q) l l

L-115-2, 0.7 mi NW (1.1 km Q) i i

l L-116-1, 0.6 mi NNW (1.0 km R) l l

l L-116-2, 0.6 mi NNW (1.0 km R) 8 l

11-3

LASALLE Revision 1.9 March 1997 Table 11-1 (Cont'd)

Radiological Environmental Monitoring Program 9

5 g

Exposure Pathway 8

i Sampling or 8

Type and Frequency and/or Samole Samole or Monitorino Locatim Collection Frecuency of Analysis i

i

_______________p_________________________________p________________ir_________________

2. Direct Radiation 8 b.

Indicators-Outer Ring 8

8 (Cont'd) l L-201-3, 4.0 mi N (6.4 km A) l l

l L-201-4, 4.0 mi N (6.4 km A) 8 l

i L-202-3, 3.6 mi NNE (5.8 km B) e i

l L-202-4, 3.6 mi NNE (5.8 km B) l l

L-203-1, 4.0 mi NE (6.4 km C) e i

l L-203-2, 4.0 mi NE (6.4 km C) l l

8 L-204-1, 3.2 mi ENE (5.2 km D) i i

l L-204-2, 3.2 mi ENE (5.2 km D) l l

l L-205-1, 3.2 mi ESE (5.2 km F) l l

L-205-2, 3.2 mi ESE (5.2 km F) i l

L-205-3, 5.1 mi E (8.2 km E) l l

L-205-4, 5.1 mi E (8.2 km E) i i

l L-206-1, 4.3 mi SE (6.9 km G) l l

l L-206-2, 4.3 mi SE (6.9 km G) e s

l L-207-1, 4.5 rni SSE (7.2 km H) l l

8 L-207-2, 4.5 rni SSE (7.2 km H) 8 e

i L-208-1, 4.5 mi S (7.2 km J) l l

l L-208-2, 4.5 mi S (7.2 km J) l l

e L-209-1, 4.0 mi SSW (6.4 km K) e i

l L-209-2, 4.0 mi SSW (6.4 km K) l l

L-210-1, 3.3 mi SW (5.3 km L) i i

l L-210-2, 3.3 mi SW (5.3 km L) l l

l L-211-1, 4.5 mi WSW (7.2 km M) 8 8

l L-211-2, 4.5 mi WSW (7.2 km M) l l

l L-212-1, 4.0 mi WSW (6.4 km M) l l

i L-212-2, 4.0 miWSW (6.4 km M) e i

l L-213-3, 4.9 mi W (7.9 km N) l l

i L-213-4, 4.9 mi W (7.9 km N) i i

l L-214-3, 5.1 mi WNW (8.2 km P) l l

L-214-4, 51 miWNW (8.2 km P) e i

l L-215-3, 5.0 mi NW (8.0 km Q) l l

i L-215-4, 5.0 mi NW (8.0 km Q) 8 i

L-216-3, 5.0 mi NNW (8.0 km R) l l

l L-216-4, 5.0 mi NNW (8.0 km R) 8 e

e 0-O

O qALLE O

Revis on 1.9

  • March 1997 Table it-1 (Cont *d)

Radiological Environmental Monitoring Program

~

i i

i l

Exposure Pathway i

i Sampling or l

Type and Frequency I

and/or Sample i

Samole or Monitoring Location Collection Freauency of Analysis i

_______________p_________________________________r________________r_________________.

2. Direct Radiation 8 c. Other 8

t I

4 (Cont'd) i e

i s

im i

i 1

1 1

i I

i 1

l One at each of the airborne location given in part 1.a l l

e and 1.b.

i I

i i

t i

I i d. Controls 8

8 8

8 I

l l

t 8

One at each airbome control locabon given in part l

l 1.c.

i e

i I

i e

I i

11-5

LASALLE Revision 1.9 March 1997 Table 11-1 (Cont'd)

Radiological Environmental Monitoring Program i

i i

Exposure Pathway I

i Sampling or i

Type and Frequency and/or Samole l

Samole or Monitoring Location l

Collection Freouency l

of Analysis i

e i

_______________p_________________________________p________________p_________________.

3. Waterbome i

i e

i e

i i

e i

8-- bO l

l

a. Indicators a Quarterly i Gamma isotopic' and tntium l

l l analysis quarterly.

i L-27. LSCS Onsite Well at Station i

l L-28, Marseilles Well, 7.0 mi NW (11.3 km Q) l l

e i

b.

Drinking Water l There is no drinking water pathway within 6.2 km l

l l

downstream of station.

l l

e e

i a

i e

i e

i c.

Surface' ater i a.

Indicator i

i W

l l Weekly grab sample l Gross beta and gamma i

L-40, l!!inois River downstream, e

i isotopic analysis on l

5.2 mi NNW (8.4 km R) l l monthly composite;intium l

l l analysis on quarterly a

e i composite.

i I

i i

e i

i i Weekly grab sample a Gross beta and gamma d.

Coritrol l a. Control l

l isotopic analysis on i

e i monthly composite;intium l

L-21, lilinois River at Seneca, l

l analysis on quarterly a

4.0 mi NE(6.4 km C) e i composite.

i e

i e

i l

l Semiannually l Gamma isotopic analysis' e.

Sediments i a. Indicators i

i semiannually.

e i

e i

i i

i L-40, Illinois River downstream, 5.2 mi NNW

.l l

l (8.4 km R) i i

a e

s

+

s e

G 94 9

p f%

(.

LASALLE Revision 1.9 March 1997 Table 11-1 (Cont'd)

Radiological Environmental Monitoring Program 3

I 5

l Sampling or l

Type and Frequency -

Exposure Pathway i

Collection Freauency i

of Analysis Sample oc.jtlonitorino Location I

and/or Sample i

i e

i

_______.________p________________________________-.p________________p_________________

8 4.

Ingedian l

l 8

' Biweekly: May through 8 Gamma isotopic' and 1-131

a. M la. Indicators l October, monthly:

! analysis

  • biweekly May nes within l November through Apn!l through October, monthly l

At the time of this revision, there are no dan..

8 November through April.

i 6.2 miles which consistently produce milk.

I e

i e

I I

e i

i b. Controls i

I i

l i

i l

i l

L-16, Lowery Dairy,7.2 mi ESE (11.6 km F) l l

i i

i i

i i

e a

i b.

Eish I a.

Indicator i

i I

e i

I i Two times annually i Gamma isotopic analysis' s

L-35, Marseilles Pool of Illinois River

  • l l on edible pc<tions of each 6.5 mi NW (10.5 km O) 8 I

I lb. Control l

l i

i L-36, Illinois River upstream of l

l l

discharge,4.3 mi NNE (6.9 km B) l l

3 I

I c.

Food Products 'l a.

Indicators l

l Two samples from each of the four major quadrants l i

l within 6.2 miles of the station.

! Annually l Gamma isotopic analysis'

' each sample' l

Sample locations for food products may vary based l l

i on availability and therefore are not required to be e

i l

identified here but shall be taken.

l i b. Controls i

i i

i e

i e

i Two samples within 9.3 to 18.6 miles of the station.

I i

e I

11-7

LASALLE Revision 1.9 March 1997 Table 11 1 (Cont'd)

Radiological Environmental Monitoring Program Far field samples are analyzed when near field results are inconsistent with previous measurements and radioactivity is confirmed as having its origin in airbome effluents refeased from the station. or at the discretion of the Radiaton Protechon Director.

Airbome particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than 10 times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.

3 Gamma isopic analysis means the idenbfication and quantification of gamma emitting radionuclides that may be attributable to the effluents from the station.

l-131 analysis means the analytical separation and counting procedure are specific for this radionuclide.

i a

e O

Od O

LASALLE Revision 1.9 March 1997 g-om.

~.

m SWW Ottaws e

~

SSRSOE I

7 L.2, L4014 L 2014 f

L-21548 LM4 L 3324 g

a L-2144 e

E L-2144 1

8, a ses.e L-21348 g4 L 21348 8 L-2054 E3

t2;;:;

  • 211 1 g gy

' 2" 8 Grand Rhlge Verona o

-m

.m im "E

10nsman J

11eRansom l

8 i

Streator 10' '

ON#%

i La SaHe County County Air Sampling Location s TLD Location CPP81TE DOSE CALCULATION 18ANUAL E Lasalle station LA SALLE COUNTY STATION FIGURE 11-1

'r, 4 =J J =J-J """*

poenamsmpumismisano Cl#WIFWNBTLD LOCATIONS 11 9

)

g LASALLE Revision 13 l

March 1997 i

g. '

e,.b1 N

116 1 L1E-8M s-

\\\\

\\

t,115-1 L 11M 185'1 5S1 j

L 1451 L 1 L 1041 l

l L-104-2

%g ).

I 4

\\hi l!

RX as

=

N I ',,M I

1,31

. e

..' 'r

-s.

s ~ ~ - 2:

7,,

j, g,7 y

x i

[

f a

u u

u u

um i

T n-r u

u u

u u is l

i

' Mh OPPSITE DOSE CALCULATION MANUAL j

LA SALLE COUNTY STATION 1;

REENE113 1

i scannsa Ti.otecAvos f

5 11-10 I

i t.

LASALLE Revision 1.9 i

March 1997 l

i w

O i

Ottawa l

Marseines u.s.s se_

N w

x i

"T#

j gi 21 nt. n j

f p

i l

1.scs a h

i l

nt.17e J

mis nansom i

i 0FFSITE DOSE CALCULATION MANUAL m

LA SALLE COUNTY STATION FIGURE 114

~

Fish INGESTION AND WATER 80RNE EXPOSURE O

a Milk PATHWAY SAMPLE LOCATIONS

+

Sediment e

Water 11-11