MONTHYEARML20217J1781999-10-13013 October 1999 Insp Rept 70-1151/99-05 on 990920-21.No Violations Noted. Major Areas Inspected:Licensee Biennial Emergency Response Exercise,Conducted on 990921 ML20210F4831999-07-22022 July 1999 Insp Rept 70-1151/99-201 on 990628-0702.No Violations Noted. Major Areas Inspected:W Commercial Nuclear Fuel Div,In Columbia,Sc,Hazard Identification & Assessment,Incident Investigation,Audits & Insps & Mgt of Change ML20196A3971999-06-11011 June 1999 Insp Rept 70-1151/99-03 on 990510-14.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interview with Plant Personnel in Areas of EP & Radiation Protection ML20206R3721999-05-14014 May 1999 Insp Rept 70-1151/99-203 on 990419-23.No Violations Noted. Major Areas Inspected:Selected Potential High Risk Activities in Facility,Including Ammonium Diuranate Processing,Powder Blending,Ventilation & Solvent Extraction ML20206P4161999-04-29029 April 1999 Insp Rept 70-1151/99-02 on 990405-08.No Violations Noted. Major Areas Inspected:Insp Occurred During Licensee Annual Outage Which Presented Unique Opportunities & Conditions to Evaluate Activities ML20207D3731999-02-26026 February 1999 Insp Rept 70-1151/99-01 on 990201-05.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Mgt Controls,Environ Protection,Waste Mgt & Facility Support ML20199F2561998-12-31031 December 1998 Insp Rept 70-1151/98-10 on 981207-11.Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Plant Personnel in Areas of Radiation Protection ML20198A8421998-12-0303 December 1998 Insp Rept 70-1151/98-09 on 981109-13.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Facility Support ML20195J2391998-11-18018 November 1998 Partially Withheld Insp Rept 70-1151/98-205 on 981019-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20155A9631998-10-13013 October 1998 Insp Rept 70-1151/98-07 on 980921-25.No Violations Noted. Major Areas Inspected:Assessment of Operational Readiness Status of Licensee Emergency Preparedness Program Changes Since Sept 1998 Insp ML20151U4771998-08-26026 August 1998 Insp Rept 70-1151/98-06 on 980803-07.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Controls,Waste Mgt,Transportation & Training ML20239A4091998-08-21021 August 1998 Insp Rept 70-1151/98-05 on 980727-31.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Review of Licensee Radiation Protection Program ML20237D7981998-08-21021 August 1998 Insp Rept 70-1151/98-204 on 980810-13.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Analysis, Internal Audits & Insps,Recently Issued Procedures & Status of Fourteen Open Items ML20236K7681998-07-0707 July 1998 Insp Rept 70-1151/98-203 on 980622-26.Violation Noted. Major Areas Inspected:Criticality Safety Program ML20249C8081998-06-26026 June 1998 Insp Rept 70-1151/98-202 on 980427-0501.Violation Noted. Major Areas Inspected:Progress Made Involving Near & Long Term Improvements in Nuclear Criticality Safety Program ML20248M1371998-06-10010 June 1998 Partially Withheld Insp Rept 70-1151/98-201 on 980504-08. Details Withheld (Ref 10CFR2.790) ML20248J6381998-05-0808 May 1998 Insp Rept 70-1151/98-03 on 980413-17.No Violations Noted. Major Areas Inspected:Safety Operations ML20203F8511998-02-20020 February 1998 Insp Rept 70-1151/98-02 on 980126-30.Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Maint of Safety Contols ML20203J5301998-02-13013 February 1998 Insp Rept 70-1151/98-01 on 980112-16.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Evaluation of Licensee Radiation Program,Environ Protection & Radwaste Mgt Programs ML20202E5061997-11-28028 November 1997 Partially Withheld Insp Rept 70-1151/97-206 on 971027-31.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20199D5071997-11-13013 November 1997 Enforcement Conference Rept 70-1151/97-207 on 971029.Areas Discussed:Seven Violations Noted in Rept 70-1151/97-205 ML20199C1311997-10-25025 October 1997 Insp Rept 70-1151/97-05 on 970922-26.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Biennial Emergency Preparedness Exercise,Including Safety Operations,Facility Support & Plant Status ML20217E0221997-10-0303 October 1997 Insp Rept 70-1151/97-205 on 970825-29.Seven Apparent Violations Noted & Are Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Licensee Root Cause Analysis & Corrective Action Implementation ML20149F9241997-07-11011 July 1997 Insp Rept 70-1151/97-04 on 970623-25.No Violations or Deviations Noted.Major Areas Inspected:Observation & Evaluation of Licensee Radioactive Waste Mgt & Environ Protection Program ML20149G7071997-07-0909 July 1997 Pre-Decisional Enforcement Conference Rept 70-1151/97-204 on 970709.Major Areas Discussed:Five Apparent Violations Noted in Insp Rept ML20141G0821997-06-24024 June 1997 Insp Rept 70-1151/97-03 on 970527-30.Violations Noted.Major Areas Inspected:Plant Operations,Mgt,Organiztion & Controls ML20137V1251997-03-28028 March 1997 Insp Rept 70-1151/97-02 on 970224-28.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Configuration Mgt & Maint of Safety Controls ML20136H6841997-03-14014 March 1997 Insp Rept 70-1151/97-202 on 970210-14.Violations Noted. Major Areas Inspected:Chemical Safety Program at W & Selected Areas That Focused on High Risk Chemicals & Use of Chemicals ML20147F7941997-03-0606 March 1997 Insp Rept 70-1151/97-01 on 970203-06.Violations Noted. Major Areas Inspected:Exam Procedures & Representative Records,Interviews W/Personnel & Observation of Activities in Progress ML20134A5351997-01-23023 January 1997 Insp Rept 70-1151/96-204 on 961216-20.Violation Noted. Major Areas Inspected:Safety Program at W & Selected Areas of Plant That Either Had Recent,Updated Criticality Safety Evaluations or Were Special Criticality Safety Interest ML20149M5141996-11-27027 November 1996 Insp Rept 70-1151/96-05 on 961029-1101.Violations Noted. Major Areas Inspected:Facility Support - Maint ML20134J4911996-11-0101 November 1996 Insp Rept 70-1151/96-03 on 960909-26.Violations Noted.Major Areas Inspected:Radiation Protection,Environ Protection & Waste Mgt ML20134F0671996-10-25025 October 1996 Insp Rept 70-1151/96-04 on 960923-27.No Violations Noted. Major Areas Inspected:Criticality Safety & Plant Operations ML20059B9031993-12-17017 December 1993 Insp Rept 70-1151/93-10 on 931115-19.Noncited Violation Identified.Major Areas Inspected:Review of Actions Licensee Has Taken in Response to Weaknesses Noted During NRC OSA ML20058P7061993-12-0606 December 1993 Insp Rept 70-1151/93-09 on 931025-29.Violations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents & Solid Radwaste Disposal & Transportation ML20058J2011993-11-23023 November 1993 Insp Rept 70-1151/93-08 on 931025-29.Violations Identified. Major Areas Inspected:Maint of Select Equipment Used in Emergency Response,Emergency Response Training & Program Changes Since Last Insp ML20058A2341993-10-18018 October 1993 Insp Rept 70-1151/93-07 on 930927-1001.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20059A0881993-10-15015 October 1993 Insp Rept 70-1151/93-06 on 930816-0916.Violations Noted. Major Areas Inspected:Review of Two Events That Occurred on 930720-0813 ML20056G8711993-08-24024 August 1993 Insp Rept 70-1151/93-05 on 930726-30.Violation Noted But Not Cited.Major Areas Inspected:Procedures,Instruments, Equipment,External Exposure Control & Control of Radioactive Matls & Contamination ML20128E9031993-02-0303 February 1993 Insp Rept 70-1151/93-201 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Controls,Internal Controls,Physical Inventories & follow-up of Unresolved Items.Details Withheld (Ref 10CFR2.790(d)) ML20125E4431992-12-0101 December 1992 Insp Rept 70-1151/92-09 on 921028 & 29.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety Program W/Specific Emphasis on Program Re Moveable, non-favorable Geometry ML20128C1761992-11-25025 November 1992 Operational Safety Assessment Rept 70-1151/92-04 on 920817- 28.Weaknesses Noted Re Control of Nonfavorable Geometry Containers.Major Areas Inspected:Process Controls,Operator Activity,Maint,Engineering & Design Control ML20062H4831990-11-19019 November 1990 Insp Rept 70-1151/90-10 on 901029-1102.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Incl Site Emergency Plan,Procedures, Facilities,Equipment & Fire Protection ML20059G9021990-09-10010 September 1990 Partially Withheld Insp Rept 70-1151/90-06 on 900813-17 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Nuclear Matl Control & Accounting Program Performance in Areas of Measurement Sys,Records & Repts ML20055H6381990-07-12012 July 1990 Insp Rept 70-1151/90-05 on 900604-08.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization & Controls,Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing & Part 21 Reportable Items ML20247H3111989-09-0101 September 1989 Insp Rept 70-1151/89-06 on 890731-0804.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Contingency Planning,Chemical Process Safety & Maint & Surveillance Testing to Prevent or Mitigate Accident ML20246A5111989-06-20020 June 1989 Insp Rept 70-1151/89-04 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Effluents,Environ Monitoring & Confirmatory Measurements ML20244D5361989-06-0101 June 1989 Insp Rept 70-1151/89-02 on 890424-28.No Violations or Deviations Identified.Major Areas Inspected:Followup on Previously Identified Items & Review of Fire Prevention/ Protection Program Implementation ML20246J1731989-05-0505 May 1989 Insp Rept 70-1151/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review,Maint & Previously Identified Items ML20244C6971989-04-0606 April 1989 Insp Rept 70-1151/89-01 on 890130-0209.Violations Noted. Major Areas Inspected:Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA & Allegations Re Radiation Protection Activities 1999-07-22
[Table view] Category:NRC-GENERATED
MONTHYEARML20217J1781999-10-13013 October 1999 Insp Rept 70-1151/99-05 on 990920-21.No Violations Noted. Major Areas Inspected:Licensee Biennial Emergency Response Exercise,Conducted on 990921 ML20210F4831999-07-22022 July 1999 Insp Rept 70-1151/99-201 on 990628-0702.No Violations Noted. Major Areas Inspected:W Commercial Nuclear Fuel Div,In Columbia,Sc,Hazard Identification & Assessment,Incident Investigation,Audits & Insps & Mgt of Change ML20196A3971999-06-11011 June 1999 Insp Rept 70-1151/99-03 on 990510-14.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interview with Plant Personnel in Areas of EP & Radiation Protection ML20206R3721999-05-14014 May 1999 Insp Rept 70-1151/99-203 on 990419-23.No Violations Noted. Major Areas Inspected:Selected Potential High Risk Activities in Facility,Including Ammonium Diuranate Processing,Powder Blending,Ventilation & Solvent Extraction ML20206P4161999-04-29029 April 1999 Insp Rept 70-1151/99-02 on 990405-08.No Violations Noted. Major Areas Inspected:Insp Occurred During Licensee Annual Outage Which Presented Unique Opportunities & Conditions to Evaluate Activities ML20207D3731999-02-26026 February 1999 Insp Rept 70-1151/99-01 on 990201-05.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Mgt Controls,Environ Protection,Waste Mgt & Facility Support ML20199F2561998-12-31031 December 1998 Insp Rept 70-1151/98-10 on 981207-11.Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Plant Personnel in Areas of Radiation Protection ML20198A8421998-12-0303 December 1998 Insp Rept 70-1151/98-09 on 981109-13.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Facility Support ML20195J2391998-11-18018 November 1998 Partially Withheld Insp Rept 70-1151/98-205 on 981019-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20155A9631998-10-13013 October 1998 Insp Rept 70-1151/98-07 on 980921-25.No Violations Noted. Major Areas Inspected:Assessment of Operational Readiness Status of Licensee Emergency Preparedness Program Changes Since Sept 1998 Insp ML20151U4771998-08-26026 August 1998 Insp Rept 70-1151/98-06 on 980803-07.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Controls,Waste Mgt,Transportation & Training ML20239A4091998-08-21021 August 1998 Insp Rept 70-1151/98-05 on 980727-31.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Review of Licensee Radiation Protection Program ML20237D7981998-08-21021 August 1998 Insp Rept 70-1151/98-204 on 980810-13.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Analysis, Internal Audits & Insps,Recently Issued Procedures & Status of Fourteen Open Items ML20236K7681998-07-0707 July 1998 Insp Rept 70-1151/98-203 on 980622-26.Violation Noted. Major Areas Inspected:Criticality Safety Program ML20249C8081998-06-26026 June 1998 Insp Rept 70-1151/98-202 on 980427-0501.Violation Noted. Major Areas Inspected:Progress Made Involving Near & Long Term Improvements in Nuclear Criticality Safety Program ML20248M1371998-06-10010 June 1998 Partially Withheld Insp Rept 70-1151/98-201 on 980504-08. Details Withheld (Ref 10CFR2.790) ML20248J6381998-05-0808 May 1998 Insp Rept 70-1151/98-03 on 980413-17.No Violations Noted. Major Areas Inspected:Safety Operations ML20203F8511998-02-20020 February 1998 Insp Rept 70-1151/98-02 on 980126-30.Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Maint of Safety Contols ML20203J5301998-02-13013 February 1998 Insp Rept 70-1151/98-01 on 980112-16.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Evaluation of Licensee Radiation Program,Environ Protection & Radwaste Mgt Programs ML20202E5061997-11-28028 November 1997 Partially Withheld Insp Rept 70-1151/97-206 on 971027-31.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20199D5071997-11-13013 November 1997 Enforcement Conference Rept 70-1151/97-207 on 971029.Areas Discussed:Seven Violations Noted in Rept 70-1151/97-205 ML20199C1311997-10-25025 October 1997 Insp Rept 70-1151/97-05 on 970922-26.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Biennial Emergency Preparedness Exercise,Including Safety Operations,Facility Support & Plant Status ML20217E0221997-10-0303 October 1997 Insp Rept 70-1151/97-205 on 970825-29.Seven Apparent Violations Noted & Are Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Licensee Root Cause Analysis & Corrective Action Implementation ML20149F9241997-07-11011 July 1997 Insp Rept 70-1151/97-04 on 970623-25.No Violations or Deviations Noted.Major Areas Inspected:Observation & Evaluation of Licensee Radioactive Waste Mgt & Environ Protection Program ML20149G7071997-07-0909 July 1997 Pre-Decisional Enforcement Conference Rept 70-1151/97-204 on 970709.Major Areas Discussed:Five Apparent Violations Noted in Insp Rept ML20141G0821997-06-24024 June 1997 Insp Rept 70-1151/97-03 on 970527-30.Violations Noted.Major Areas Inspected:Plant Operations,Mgt,Organiztion & Controls ML20137V1251997-03-28028 March 1997 Insp Rept 70-1151/97-02 on 970224-28.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Configuration Mgt & Maint of Safety Controls ML20136H6841997-03-14014 March 1997 Insp Rept 70-1151/97-202 on 970210-14.Violations Noted. Major Areas Inspected:Chemical Safety Program at W & Selected Areas That Focused on High Risk Chemicals & Use of Chemicals ML20147F7941997-03-0606 March 1997 Insp Rept 70-1151/97-01 on 970203-06.Violations Noted. Major Areas Inspected:Exam Procedures & Representative Records,Interviews W/Personnel & Observation of Activities in Progress ML20134A5351997-01-23023 January 1997 Insp Rept 70-1151/96-204 on 961216-20.Violation Noted. Major Areas Inspected:Safety Program at W & Selected Areas of Plant That Either Had Recent,Updated Criticality Safety Evaluations or Were Special Criticality Safety Interest ML20149M5141996-11-27027 November 1996 Insp Rept 70-1151/96-05 on 961029-1101.Violations Noted. Major Areas Inspected:Facility Support - Maint ML20134J4911996-11-0101 November 1996 Insp Rept 70-1151/96-03 on 960909-26.Violations Noted.Major Areas Inspected:Radiation Protection,Environ Protection & Waste Mgt ML20134F0671996-10-25025 October 1996 Insp Rept 70-1151/96-04 on 960923-27.No Violations Noted. Major Areas Inspected:Criticality Safety & Plant Operations ML20059B9031993-12-17017 December 1993 Insp Rept 70-1151/93-10 on 931115-19.Noncited Violation Identified.Major Areas Inspected:Review of Actions Licensee Has Taken in Response to Weaknesses Noted During NRC OSA ML20058P7061993-12-0606 December 1993 Insp Rept 70-1151/93-09 on 931025-29.Violations Noted.Major Areas Inspected:Radiological Liquid & Gaseous Effluents & Solid Radwaste Disposal & Transportation ML20058J2011993-11-23023 November 1993 Insp Rept 70-1151/93-08 on 931025-29.Violations Identified. Major Areas Inspected:Maint of Select Equipment Used in Emergency Response,Emergency Response Training & Program Changes Since Last Insp ML20058A2341993-10-18018 October 1993 Insp Rept 70-1151/93-07 on 930927-1001.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection ML20059A0881993-10-15015 October 1993 Insp Rept 70-1151/93-06 on 930816-0916.Violations Noted. Major Areas Inspected:Review of Two Events That Occurred on 930720-0813 ML20056G8711993-08-24024 August 1993 Insp Rept 70-1151/93-05 on 930726-30.Violation Noted But Not Cited.Major Areas Inspected:Procedures,Instruments, Equipment,External Exposure Control & Control of Radioactive Matls & Contamination ML20128E9031993-02-0303 February 1993 Insp Rept 70-1151/93-201 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Controls,Internal Controls,Physical Inventories & follow-up of Unresolved Items.Details Withheld (Ref 10CFR2.790(d)) ML20125E4431992-12-0101 December 1992 Insp Rept 70-1151/92-09 on 921028 & 29.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety Program W/Specific Emphasis on Program Re Moveable, non-favorable Geometry ML20128C1761992-11-25025 November 1992 Operational Safety Assessment Rept 70-1151/92-04 on 920817- 28.Weaknesses Noted Re Control of Nonfavorable Geometry Containers.Major Areas Inspected:Process Controls,Operator Activity,Maint,Engineering & Design Control ML20062H4831990-11-19019 November 1990 Insp Rept 70-1151/90-10 on 901029-1102.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Incl Site Emergency Plan,Procedures, Facilities,Equipment & Fire Protection ML20059G9021990-09-10010 September 1990 Partially Withheld Insp Rept 70-1151/90-06 on 900813-17 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Nuclear Matl Control & Accounting Program Performance in Areas of Measurement Sys,Records & Repts ML20055H6381990-07-12012 July 1990 Insp Rept 70-1151/90-05 on 900604-08.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization & Controls,Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing & Part 21 Reportable Items ML20247H3111989-09-0101 September 1989 Insp Rept 70-1151/89-06 on 890731-0804.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls, Contingency Planning,Chemical Process Safety & Maint & Surveillance Testing to Prevent or Mitigate Accident ML20246A5111989-06-20020 June 1989 Insp Rept 70-1151/89-04 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Effluents,Environ Monitoring & Confirmatory Measurements ML20244D5361989-06-0101 June 1989 Insp Rept 70-1151/89-02 on 890424-28.No Violations or Deviations Identified.Major Areas Inspected:Followup on Previously Identified Items & Review of Fire Prevention/ Protection Program Implementation ML20246J1731989-05-0505 May 1989 Insp Rept 70-1151/89-03 on 890417-21.No Violations & Deviations Noted.Major Areas Inspected:Mgt Controls, Training,Nuclear Criticality Safety,Operations Review,Maint & Previously Identified Items ML20244C6971989-04-0606 April 1989 Insp Rept 70-1151/89-01 on 890130-0209.Violations Noted. Major Areas Inspected:Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA & Allegations Re Radiation Protection Activities 1999-07-22
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20217J1781999-10-13013 October 1999 Insp Rept 70-1151/99-05 on 990920-21.No Violations Noted. Major Areas Inspected:Licensee Biennial Emergency Response Exercise,Conducted on 990921 ML20210F4831999-07-22022 July 1999 Insp Rept 70-1151/99-201 on 990628-0702.No Violations Noted. Major Areas Inspected:W Commercial Nuclear Fuel Div,In Columbia,Sc,Hazard Identification & Assessment,Incident Investigation,Audits & Insps & Mgt of Change ML20196A3971999-06-11011 June 1999 Insp Rept 70-1151/99-03 on 990510-14.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interview with Plant Personnel in Areas of EP & Radiation Protection ML20206R3721999-05-14014 May 1999 Insp Rept 70-1151/99-203 on 990419-23.No Violations Noted. Major Areas Inspected:Selected Potential High Risk Activities in Facility,Including Ammonium Diuranate Processing,Powder Blending,Ventilation & Solvent Extraction ML20206P4161999-04-29029 April 1999 Insp Rept 70-1151/99-02 on 990405-08.No Violations Noted. Major Areas Inspected:Insp Occurred During Licensee Annual Outage Which Presented Unique Opportunities & Conditions to Evaluate Activities ML20207D3731999-02-26026 February 1999 Insp Rept 70-1151/99-01 on 990201-05.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Mgt Controls,Environ Protection,Waste Mgt & Facility Support ML20199F2351998-12-31031 December 1998 Notice of Violation from Insp on 981207-11.Violation Noted: Inspectors Observed Operations Involving Nuclear Matl Not Being Conducted IAW Approved Procedures ML20199F2561998-12-31031 December 1998 Insp Rept 70-1151/98-10 on 981207-11.Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Plant Personnel in Areas of Radiation Protection ML20198A8421998-12-0303 December 1998 Insp Rept 70-1151/98-09 on 981109-13.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Facility Support ML20195J2391998-11-18018 November 1998 Partially Withheld Insp Rept 70-1151/98-205 on 981019-23. Violations Noted.Details Withheld,Per 10CFR2.790 ML20155A9631998-10-13013 October 1998 Insp Rept 70-1151/98-07 on 980921-25.No Violations Noted. Major Areas Inspected:Assessment of Operational Readiness Status of Licensee Emergency Preparedness Program Changes Since Sept 1998 Insp ML20151T1421998-08-26026 August 1998 Notice of Violation from Insp on 980803-07.Violation Noted: as of 980806,three Individuals,Who in Course of Employment Likely to Receive in Year Occupational Dose in Excess of 100 Mrem,Not Instructed in Applicable Provisions of Regulations ML20151U4771998-08-26026 August 1998 Insp Rept 70-1151/98-06 on 980803-07.Violations Noted. Major Areas Inspected:Plant Operations,Mgt Controls,Waste Mgt,Transportation & Training ML20239A4091998-08-21021 August 1998 Insp Rept 70-1151/98-05 on 980727-31.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Review of Licensee Radiation Protection Program ML20237D7981998-08-21021 August 1998 Insp Rept 70-1151/98-204 on 980810-13.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Analysis, Internal Audits & Insps,Recently Issued Procedures & Status of Fourteen Open Items ML20236K7651998-07-0707 July 1998 Notice of Violation from Insp on 980622-26.Violation Noted: Licensee Failed to Verify Calculations That Support Criticality Safety Limits ML20236K7681998-07-0707 July 1998 Insp Rept 70-1151/98-203 on 980622-26.Violation Noted. Major Areas Inspected:Criticality Safety Program ML20249C8081998-06-26026 June 1998 Insp Rept 70-1151/98-202 on 980427-0501.Violation Noted. Major Areas Inspected:Progress Made Involving Near & Long Term Improvements in Nuclear Criticality Safety Program ML20249C8071998-06-26026 June 1998 Notice of Violation from Insp on 980427-0501.Violation noted:1008 Ammonia Scrubber Was Operated Since May 1997 W/Inoperable Nuclear Criticality Safety Control ML20248M1371998-06-10010 June 1998 Partially Withheld Insp Rept 70-1151/98-201 on 980504-08. Details Withheld (Ref 10CFR2.790) ML20248J6381998-05-0808 May 1998 Insp Rept 70-1151/98-03 on 980413-17.No Violations Noted. Major Areas Inspected:Safety Operations ML20203F8461998-02-20020 February 1998 Notice of Violation from Insp on 980126-30.Violation Noted: Licensee Failed to Conduct Activities IAW Requirements for Utilizing Computer Programs &/Or Approved Procedures as Evidenced by Following List ML20203F8511998-02-20020 February 1998 Insp Rept 70-1151/98-02 on 980126-30.Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety & Maint of Safety Contols ML20203J5301998-02-13013 February 1998 Insp Rept 70-1151/98-01 on 980112-16.No Violations Noted. Major Areas Inspected:Observation of Work Activities & Evaluation of Licensee Radiation Program,Environ Protection & Radwaste Mgt Programs ML20198H6551998-01-0606 January 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $13,750 from Insp Conducted on 970825-29. Violations Noted:Licensee Failed to Conduct Adequate Incident Investigation & Followup Actions ML20199A1881997-12-30030 December 1997 EN-97-118:on 980105,notice of Proposed Imposition of Civil Penalty in Amount of $13,750 Issued to Licensee.Action Based on Eight Violations Involving Criticality Safety Controls Considered in Aggregate to Represent Severity Level III ML20202E5061997-11-28028 November 1997 Partially Withheld Insp Rept 70-1151/97-206 on 971027-31.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20199D5071997-11-13013 November 1997 Enforcement Conference Rept 70-1151/97-207 on 971029.Areas Discussed:Seven Violations Noted in Rept 70-1151/97-205 ML20199C1311997-10-25025 October 1997 Insp Rept 70-1151/97-05 on 970922-26.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Licensee Biennial Emergency Preparedness Exercise,Including Safety Operations,Facility Support & Plant Status ML20217E0221997-10-0303 October 1997 Insp Rept 70-1151/97-205 on 970825-29.Seven Apparent Violations Noted & Are Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Licensee Root Cause Analysis & Corrective Action Implementation ML20149K9121997-07-28028 July 1997 Notice of Violation from Insp on 970505-07.Violation Noted: Licensee Failed to Provide Required Notifications in That on 961016,licensee Had Indications That Two Fuel Rods Were Missing & on 961020,failed to Notify NRC within 1 H ML20149F9241997-07-11011 July 1997 Insp Rept 70-1151/97-04 on 970623-25.No Violations or Deviations Noted.Major Areas Inspected:Observation & Evaluation of Licensee Radioactive Waste Mgt & Environ Protection Program ML20149G7071997-07-0909 July 1997 Pre-Decisional Enforcement Conference Rept 70-1151/97-204 on 970709.Major Areas Discussed:Five Apparent Violations Noted in Insp Rept ML20141G0821997-06-24024 June 1997 Insp Rept 70-1151/97-03 on 970527-30.Violations Noted.Major Areas Inspected:Plant Operations,Mgt,Organiztion & Controls ML20141G0731997-06-24024 June 1997 Notice of Violation from Insp on 970527-30.Violation Noted:Configuration Control Forms W/Dockets 95-135,96-042 & 96-191 Had Been Signed as Being Completed,But Documentation Had Not Been Revised for Updated Drawings & Loop Sheets PNO-II-97-021, on 970415,Westinghouse Informed NRC That Low Enriched U Fuel Rods Could Not Be Located.Licensee Stated No Evidence of Theft or Unlawful Diversion of Two Fuel Rods. State of Sc Notified1997-04-18018 April 1997 PNO-II-97-021:on 970415,Westinghouse Informed NRC That Low Enriched U Fuel Rods Could Not Be Located.Licensee Stated No Evidence of Theft or Unlawful Diversion of Two Fuel Rods. State of Sc Notified ML20137V1251997-03-28028 March 1997 Insp Rept 70-1151/97-02 on 970224-28.No Violations Noted. Major Areas Inspected:Licensee Programs for Operational Safety,Configuration Mgt & Maint of Safety Controls ML20136H6751997-03-14014 March 1997 Notice of Violation from Insp on 970210-14.Violation Noted:As of 970214 Emergency Procedures Issued by Licensee Were Not Approved by Cognizant Regulatory Component Manager Until After Procedures Had Been Issued & Implemented ML20136H6841997-03-14014 March 1997 Insp Rept 70-1151/97-202 on 970210-14.Violations Noted. Major Areas Inspected:Chemical Safety Program at W & Selected Areas That Focused on High Risk Chemicals & Use of Chemicals ML20147F7941997-03-0606 March 1997 Insp Rept 70-1151/97-01 on 970203-06.Violations Noted. Major Areas Inspected:Exam Procedures & Representative Records,Interviews W/Personnel & Observation of Activities in Progress ML20147F7821997-03-0606 March 1997 Notice of Violation from Insp on 970203-06.Violation Noted:Chewing Gum & Food Products Were Used in Chemical Area as Evidenced by Discarded Chewing Gum & Candy Wrappers & MCC Containers Had Not Been Reinspected in 5 Yrs ML20134A5351997-01-23023 January 1997 Insp Rept 70-1151/96-204 on 961216-20.Violation Noted. Major Areas Inspected:Safety Program at W & Selected Areas of Plant That Either Had Recent,Updated Criticality Safety Evaluations or Were Special Criticality Safety Interest ML20134A4901997-01-23023 January 1997 Notice of Violation from Insp on 961216-20.Violation Noted: Monthly Formal Audit of Regulatory Program Performance Conducted on 961217,under Guidance Provided in RA-102, Regulatory Compliance Insp,Rev 7,was Inadequate ML20149M5141996-11-27027 November 1996 Insp Rept 70-1151/96-05 on 961029-1101.Violations Noted. Major Areas Inspected:Facility Support - Maint ML20149M5121996-11-27027 November 1996 Notice of Violation from Insp on 961029-1101.Violation Noted:License Requires Use of Special Nuclear Matl IAW Statements,Representations & Conditions in License Application ML20134J4841996-11-0101 November 1996 Notice of Violation from Insp on 960909-26.Violation Noted: Audit Not Conducted as Required by SEP ML20134J4911996-11-0101 November 1996 Insp Rept 70-1151/96-03 on 960909-26.Violations Noted.Major Areas Inspected:Radiation Protection,Environ Protection & Waste Mgt ML20134F0671996-10-25025 October 1996 Insp Rept 70-1151/96-04 on 960923-27.No Violations Noted. Major Areas Inspected:Criticality Safety & Plant Operations ML20059B9031993-12-17017 December 1993 Insp Rept 70-1151/93-10 on 931115-19.Noncited Violation Identified.Major Areas Inspected:Review of Actions Licensee Has Taken in Response to Weaknesses Noted During NRC OSA ML20058P6991993-12-0808 December 1993 Notice of Violation from Insp on 931025-29.Violations Noted: Licensee Failed to Meet Requirements for DOT Shipping Descriptions as Listed 1999-07-22
[Table view] |
Text
,. 1
) -1 U.S. NUCLEAR REGULATORY COMMISSION REGION 11
. Docket No.: '70-1151
- License No.: SNM-1107 Report No.: 70-1151/99-05 Licensee: Westinghouse Electric Corporation Facility Name: . Commercial Nuclear Fuel' Division Date: September 20-21,1999 Inspector: A. Gooden, Radiation Specialist Approved by: E. J. McAlpine, Chief .
Fuel Facilities Branch Division of Nuclear Materials Safety e
Enclosure l
9910250037 991013 PDR ADOCK 07001151 PDR
h -. ; ,
4
(
L EXECUTIVE
SUMMARY
Commercial Nuclear Fuel Division
. NRC Inspection Report 70-1151/99-05 I
l- This routine announced inspection involved the observation and evaluation of the licensee's
!* biennial emergency response exercise, conducted September 21,1999. The report entails a two day inspection effort by a regional based radiation specialist.
)
- - The licensee's response to the postulated accident was considered a successful demonstration of the licensee's response capability to protect the health and safety of plant workers and the public (Paragraph 2.a.(2)). _
)
- - Based on the exercise and critique observations, interviews, and documentation, the licensee was conducting drills and exercises in accordance with Section 7.4 of the Plan (Paragraph 2.a.(3)).
- The scenario details provided an adequate test of the onsite response capability j (Paragraph 2.a.(3)). .j l
I
' Attachment-
. Persons Contacted .
List of items Opened, Closed, and Discussed -
- List of Acronyms Scenario Description and Exercise Objectives i
4 -
O.
4
x .
[' REPORT DETAILS
- 1. ' Summarv of Plant Status :
, - There.were no unusual plant opdational occurrences during the inspection. Plant
- operations were normal with routine maintenance activities.
~
~ 2. Emeroency Preoaredness (88050) (F3)
- a. Drills and Exercises (F3.05) l(1)' Inspection Scooe
! J
, Section 7.4 of the Emergency Plan required that biennially an emergency exercise be l conducted. The exercise scenario and objectives were reviewed for adequacy in testing ,
the onsite response capability. The effectiveness of the licensee's critique to self identify '
areas of improvement was also reviewed.
l(2) Observations and Findinas The' licensee submitted for NRC review the information on the scope, objectives, and scenario in advance of the exercise date. Minor problems were identified and resolved in advance of the exercise. The exercise scenario simulated an accident which resulted
- in the release of nitrogen dioxide from a reaction involving UO 2 powder with nitric acid inside the uranium scrap area. An operatorwas postulated as contaminated and overcome by fumes from the nitrogen dioxide cloud. The scenario and associated '
messages were adequate and provided exercise participants with a set of conditions to demonstrate various aspects of the emergency response program. The exercise commenced at approximately 4:30 a.m. and was terminated around 5:58 a.m.
- Exercise participants included the Richland County Emergency Medical Services, and the local hospital. The exercise starting time of 4:30 a.m. presented a significant
! . challenge to the licensee due to shortage of resources available to respond during the I back-shift.' in response to the simulated emergency, the on-shift Emergency Coordinator (EC) implemented the Plan and Emergency Procedures, and correctly classified the
- emergency and completed the offsite notifications in a timely manner. The licensee's
. response to the postulated accident was considered a successful demonstration of the licensee's response capability to protect the health and safety of plant workers and the w public. ' As required by the Emergency Plan, the licensee conducted a critique following the exercise which afforded players,_ controllers, evaluators, and observers an y opportunity in provide comments.' Severalitems were identified as requiring corrective
- actions during the licensee's self critique. In addition, the following items were identified by the NRC evaluator as_ requiring corrective actions
- . (1) security failed to notify the emergency response organization in accordance with procedures and resulted in an b -c inadequate number of staff to activate the Emergency Control Center; (2) the Radiation Protection Coordinator evacuated to the assembly location rather than the incident command post (ICP) resulting in a lack of understanding by radiation protection
. personnel regarding the materialinvolved, and no health physics expertise was
. immediately available to advise the EC at the ICP; and (3) the EC failed to brief the O '
p .' s l l
l l 2 emergency staff (both onsite and arriving personnel) regarding the status of the event, concept of operation,'and strategies for mitigation activities. The licensee was l informed that the corrective actions to items identified by the exercise controller /
evaluator team and NRC evaluator would be tracked as an inspector followup item (IFl 70-1151/ 99-05-01). The actions taken by the licensee to review, assign, and track corrective actions to resolution will be reviewed during a subsequent inspection.
(3) ConcluCas Based on the exercise and critique observations, interviews, and documentation, the licensee was conducting drills and exercises in accordance with Section 7.4 of the Plan.
The scenario details provided an adequate test of the onsite response capaoility. The critique process was effective in the identification of emergency response strengths and weaknesses, and items requiring corrective actions. The licensee's respon.es to the postulated accident was considered a successful dernonstration of an emergency response program properly maintained to protect onsite workers and the offsite public.
- b. Follow Jo On Previousiv identified items (F3.07)
(1) Insoection Scoce The inspector reviewed actions taken by the licensee to correct previous issues to verify that the corrective actions were adeouate and had been completed.
(2) Observations and Findinas -
- (Closed) IFl 70-1151/99-03-01: Review corrective actions to ensure consistency l in the event classification for hazardous weather. i The inspector reviewed the revised Emergency Procedure A-04 governing event classification and noted that the procedure incorporated greater than 73 mph as the criteria for hurricane force winds.
9 (Closed) IFl 70-1151/99-03-02: Verify corrective actions taken to restore the onsite capability for measuring wind speed and direction.
The inspector verified via observation that the onsite capability was operational.
The licensee indicated that in spite of the operational status, the investigation into a replacement system continues.
(3) Conclusions Based on the licensee's actions, both items were closed.
l l
e L_
3
- 3. Exit Interview
The inspection scope and results were summarized u September'21,1999, with those persons indicated in the Attachment. Although proprietary documents and processes were occasionally reviewed during this inspection, the proprietary nature of these documents or processes has been deleted from this report. No dissenting comments were received from the licensee.
97 l
[
6 i ATTACHMENT l l
LIST OF PERSONS CONTACTED Licensee
- C. Aguilar, Senior _ Regulatory Engineer i
- J. Ailen, Plant Manager l
- G. Dullock, Conversion Team Manager l
- J. Bush, Manager, Manufacturing
- R. Close, Maintencoce Team Manager; D. Gadberry, Supervisor, Security
- D. Goldbach, Manager, Regulatory Affairs
- W. Goodwin, Advisory Engineer
- J. Heath, Manager, Regulatory Engineering and Operations
- J. Hooper, Senior Regulatory Engineer )
- R. Jacobs, Conversion Team Manager l
- A. Kaminsky, Human Resources Manager I
- E. Keelen, Manager, Quality Assurance l
- S. Mcdonald, Manager, Technical Services .
- C. Perkins, Manager, Maintenance
'E. Reitler, Fellow Engineer
- P. Stroud, Manager, Security
- R. Williams, Advisory Engineer l Other licensee employees contacted included engineers, technicians, security and office personnel. -
- Attended exit meeting on September 21,1999 INSPECT,0N PROCEDURES USED IP 88050 Emergency Preparedness LIST OF ITEMS OPENED. CLOSED. AND DISCUSSED ltem Number Status Descriotion 70-1951/99-03-01 Closed IFl . Review corrective actions to ensure consistency in the event classification for hazardous weather (Paragraph 2.b.(2)).
70-1151/99-03-02 Closed IFl - Verify corrective actions taken to restore the onsite L capability for measuring wind speed and direction (Paragraph 2.b.(2)).
70-1151/99-05-01 Open IFl -Verify the corrective actions to items identified during the exercise (Paragraph 2.a.(2)).