ML20202E506

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Rept 70-1151/97-206 on 971027-31.No Violations Noted.Details Withheld,Per 10CFR2.790
ML20202E506
Person / Time
Site: Westinghouse
Issue date: 11/28/1997
From:
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19317C742 List:
References
70-1151-97-206, NUDOCS 9712080053
Download: ML20202E506 (1)


Text

DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED i

U S. NUCLEAR REGULATORY COMMISSION,

OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS Docket No.:

70-1151 Licenr.e No.:

SNM 1107 Report No.:

70-1151/97-206 Safeguards Group:

lli Licensee:

Westinghouse Electric Corporation Commercial Nuclear Fuel Divisir Columbia Fuel Fabrication Facility Location-P.O. Box R Columbia, S.C. 29250 Dates' October 27-31,1997 Inspectors:

E. Eckfeld, MC&A Physical Scientist, inspection Section C. Collins, MC&A Physical Scientist, inspection Section Approved by:

P. Ting, Chief Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS Enclosure DECONTROLLED WHEN 2.790 INFORMATION IS REMOc.D DOCUMENT TRANSMITTED HEREWITH CONTAINS 2.790 INFORMATION 9712000053 971128

~

PDR ADOCK 07001151 C

pm