ML20214W825
| ML20214W825 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 12/05/1986 |
| From: | Heitner K Office of Nuclear Reactor Regulation |
| To: | Robert Williams PUBLIC SERVICE CO. OF COLORADO |
| References | |
| TAC-56743, NUDOCS 8612100415 | |
| Download: ML20214W825 (4) | |
Text
-
D cember 5, 1986 l
lDocketNo.50-267 f
Mr. R. O. Williams, Jr.
Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840
Dear Mr. Williams:
SUBJECT:
TECHNICAL SPECIFICATIONS FOR ADMINISTRATIVE CONTROLS, REQUEST FOR ADDITIONAL INFORMATION We are reviewing your submittal dated July 22, 1986 (P-86452) proposing changes to the Fort St. Vrain Technical. Specifications for Administrative Controls. During our review we have found this submittal does not contain adequate information'concerning the Plant Operations Review Committee.
Enclosed is a request for additional information concerning this issue.
Please provide this information within 30 days of the date of this letter.
The information requested in this letter affects fewer than 10 respondents; therefore 0MB clearance is not required under P.L.96-511.
Sincerely, original signed by Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/ enclosure:
See next page DISTRIBUTION:
Docket File a EJordan KHeitner NRC PDR BGrimes 0 Lynch Local PDR JPartlow HBerkow PBSS Reading HThompson WRegan, F0B FMiraglia ACRS (10)
OGC-Bethesda PNoonan Fhj PBfShQ PBSS N B
n KHeitner:cw OL nch WRegan HBerkow g /86 12/4/86 12/j/86 12/f/86 12/g/86 861210041S 861205 PDR ADOCK 05000267 p
PDR 1
r
,p ung
['
~ f,,
UNITED STATES g
NUCLEAR REGULATORY COMMISSION
- j 5
-l WASHINGTON, D. C. 20555 o,
/c December 5, 1986
- ...+
Docket No. 50-267 Mr. R. O. Williams, Jr.
Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840
Dear Mr. Williams:
SUBJECT:
TECHNICAL SPECIFICATIONS FOR ADMINISTRATIVE CONTROLS, REQUEST
^
FOR ADDITIONAL INFORMATION We are reviewing your submittal dated July 22,1986(P-86452) proposing changes to the Fort St. Vrain Technical Specifications for Administrative Controls. During our review we have found this submittal does not contain adequate information concerning the Plant Operations Review Committee.
Enclosed is a request for additional information concerning this issue.
Please provide this information within 30 days of the date of this letter.
The infonnation requested in this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.
Sincerely, m
Kenrcth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/ enclosure:
See next page
Mr. R. O. Williams ej Public Service Company of Colorado Fort St. Vrain CC:
Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein, 14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc.
Nuclear Production Division Post Office Box 85608 Public Service Company of Co}orado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. P. F. Tomlinson, Manager Public Service Company of Colorado Quality Assurance Division P. O. Box 840 Public Service Company of Colorado Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission Mr. R. F. Walker P. 0. Box 840 Public Service Company of Colorado Platteville, Colorado 80651 Post Office Box 840 Denver, Colorado 92138 Kelley, Stansfield & 0'Donnell Public Service Company Building Commitment Control Program Room 900 Coordinator 550 15th Street Public Service Ca pany of Colorado Denver, Colorado 80202 2420 W. 26th Ave. Suite 100-D Denver, Colorado 80211 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Chaiman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 Regional Representative Radiation Programs Environmental Protection Agency 1 Denver Place 999 18th Street, Suite 1300 Denver, Colorado 80202-2413
Enclosure PUBLIC SERVICE COMPANY OF COLORADO FORT ST. VRAIN NUCLEAR GENERATING STATION REQUEST FOR ADDITIONAL INFORMATION In a letter dated July 22, 1986, the Public Service Company of Colorado (PSC) requested changes to the Administrative Controls Section of the Technical Specifications for Fort St. Vrain Nuclear Generating Station. These proposed changes involved revisions to the Management Organization Chart (Figure 7.1-1),
and Fort St. Vrain Nuclear Generating Station Organization Chart (Figure 7.1-2).
The following is a request for additional information with respect to these changes:
PSC has added the new position " Superintendent Scheduling / Planning and Stores" to the Plant Operations Review Committee. This raises the total committee membership to at least 15 members, but retains a quorum of only 5 members. The qucrum requirement is normally established to represent a majority of the members of the committee to ensure continuity from one meeting to another. Describe PSC's provisions for ensuring that continuity of members is retained from one meeting to the next meeting.
Alternatively, revise the quorum requirement to be a majority of the members.
- - - -