ML20213G002

From kanterella
Jump to navigation Jump to search
Exam Rept 50-254/OL-86-03 on 861014-16.Exam results:5 of 9 Senior Reactor Operators & 6 of 7 Reactor Operators Passed Exams.Requalification Program Evaluation Rept & Exam & Answer Key Encl
ML20213G002
Person / Time
Site: Quad Cities  
Issue date: 11/12/1986
From: Bishop M, Burdick T, Dave Hills, Lanksbury R, Morgan T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20213F979 List:
References
50-254-OL-86-03, 50-254-OL-86-3, NUDOCS 8611170277
Download: ML20213G002 (76)


Text

.-

h U.S. NUCLEAR REGULATORY COMMISSION REGION III Report No. 50-254/0L-86-03 j

Docket Nos. 50-254; 50-265 Licenses No. DPR-29; DPR-30 i

Licensee: Connonwealth Edison Company Post Office Box 767 Chicago, IL 60690 Facility Nane: Quad Cities Nuclear Power Station Examination Administered At: Quad Cities Nuclear Power Station Examination Conducted: October 14-16, 1986 N.YYb-Examiners:

D. Hills

/ /_~( /C e

J) b..ll)Dl%

. Lan s y

+

ate Y$

M. Bishop

_ / /_h/f4 YNb Dart

/fc

// / t

/

T. Morgan i

7

/

Y I

Approved By:

. M.

, Chief Operator Licensing Section ate' Eyam_inati_on Summary Examination administered on October 14-16, 1986 Report NoS0-254/0L-86-03).

Written and oraTi~e~qiiaTiriFa~tloiG~xaiiiiiiiaYiiin~s~ile_r(e a~ din ~iiilstered t'o i

~~ ~

Reactor Operators (SRO) and seven Reactor Operators (RO).

_Resul ts :

Five SR0's and six R0's passed these examinations. All others failed one or more portions of the examination.

The Requalification Program Evaluation Report is contained in Attachment 1.

i 8611170277 861114 i

PDR ADOCK 05000254 V

PDR

s-T f

REPORT DET_A_I_L_S _

1.

Examiners D. Hills - Chief Examiner

,^

R. Lanksbury M. Bishop T. Morgan 2.

Examination, Review pteetjng Specific facility concents conceim:ng written examination questions, folicwed by the NRC respor.se, areknumerated in Attachment 2.

3.

Exit MeetinS Attheconclu$ionoftheexaminations,anexitmeetingwasconducted.

The fcilowing personnel attended this exit n]eeting.

Facility _R_epresentatives x

R. Bax, Station Manager T. Tamlyn, Production Superintendent R. Robey, Services Superintendent G. Tietl, h sistant Superintendent, Operations W. Graham, Principle Instructor M. Kooi, Regulatory Assurance R. Svaleson, Instructor, General Electric NRC Representatives C. Hehl, Chief, Operations Branch D. Hills, Operator Licensing Ex6 miner R. Laiksbury, Operator Licensing Examiner The follcwing itens were discussed:

.i a.

A generic deficier.cy involving inplementa; tion of energency precedures identified during the oral exanlaations.

b.

Inconsistency'in requirements for whole bcoy countt. for visiting NRC examiners. The Itcensee was advised that in the f!ture the examiner should be inforned of the current requirements prior to the examination trip.

Thus, sufficient time can be appropriately figured into the examination schedule, f

Requalification program evaluation guidelines irrd perforkance.

c.

4

\\

l

-)

ES-601-4 ATTACHMENT #1 REQUALIFICATIOC PROGRAM EVALUATION REPORT Facility:

Quad-Ci ties Examiner:

n_ yills Date(s) of Evaluation:

10/14-16/86 Areas Evaluated:

X Written X

Oral Simulator Examination Results:

RO SRO Total Evaluation Pass / Fail Pass / Fail Pass / Fail (S, M, or U)

Written Examination 6/1 5/4 11/5 M

Operating Examination Oral 7/0 8/1 15/1 S

Simulator N/A N/A N/A N/A Evaluation of facility written examination grading N/A Overall Program Evaluation Satisfactory Marginal Unsatisfactory X

(List major defi-The overall program evaluation as unsatisfactory is based ciency areas with upon the results of these examinations conducted October brief descriptive 14-16, 1986, and the results of previous examinations comments) conducted September 15-17, 1986 (Examination Report No. 50-254/0L-86-02).

The written examination results indicated a generic weakness in both abnornal and normal procedures in addition to technical specifications.

Furthermore, the oral examination results indicated the ability to actually implement the emergency procedures as an additional major deficiency area.

Submitted:

Forwarded:

Approved-Y.$

E8k b

bl(

v' O

Examiner Section Chief l' Branch Chief D. E. Hills T. M. Burdick C. W. Hehl l

l

ATTACHMENT #2 l

QUA0 CITIES 1 8 2 REACTOR OPERATOR AND SENIOR REACTOR OPERATOR REPLACEE NT EXAMINATION REACTOR OPERATOR AND SENIOR REACTOR OPERATOR REQUALIFICATION EXAMINATION OCTOBER 14. 1986 1.12 Facility Comment:

Another answer that should be acceptable for this question is to maintain proper reactor water level to prevent carry under. The Reactor Vessel and Internals text lists carry under as a factor that will lower recirc pump NPSH. Pages 14 and 15 of this text are attached.

(Also applicable to replacement question 5.11 and requalification questions 1.06 and 5.05).

Resolution:

Cross referenced to R0 1.12 & SR0 5.11 Replacement R0 1.06 & SR0 5.05 Requalification Connent noted but not accepted. The items requested to be included are already referred to in the answer, i.e. maintain proper water level to prevent carry under. This is addressed with the answer referring to low reactor vessel water level trip.

No change to the answer. key will be made.

1.14 Facility Comment:

QCHPS is currently using the General Electric BWR Academic Series Heat Transfer and Fluid Flow for instruction in this area. This material includes "deration of power increase" as a factor for PCI failures and should also be considered an acceptable answer, as it is synonymous to the items listed on the key. A copy of page 9-47 is attached.

(Also applicable to replacement question 5.13 and I

requalification question 1.08.)

f Resolution:

Cross referenced to R0 1.14 & SRO 5.13 Replacement R0 1.08 Requalification i

Comment noted and accepted.

"Ouration of power increase" will be added to the answer key as an additional correct answer. Answer point breakdown remains unchanged. Page 9-47 will be added to the reference along with QC.LIC-0201-2, Nuclear Fuel Lesson Plan page 20.

2.03.c.

Facility Comment:

This question is extremely confusing because it is not clear what the status of the flow converter upscale trip unit is. The question I

states that the units are upscale, yet also states that the flow is

~

less than 108%. The trip setting for this at QCNPS is 110%.

If the student assumes an actual upscale trip is present, the answer key is correct in specifying a rod block exists, however, if the student merely assumes it is a high reading and a trip does not exist, since the setpoint has not been reached, then no trip is the correct response. Apparently several candidates questioned the examiners on this and were left with different impressions.

In this case, either no trip or rod block should be considered correct, however, half scram should be considered erroneous. Page 4 of the APRM lesson plan is attached to describe the trip.

(Also applicable to replacement question 6.01 requalification questions 2.02 and 6.01.)

Resolution:

Cross referenced R0 2.03 & SR0 6.01 Replacement R0 2.02 & SRO 6.01 Requalification Conment is accepted. The answer key will be changed to "no reactor protective system action" as would be the case if the flow units failed to the 108 or 107% position. When questioned during the exam it was stated the flow units fail upscale to 108%. Point breakdown remains unchanged.

2.06 Facility Comment:

Parts of this answer are in error and another auto start signal at 2000 R/hr drywell radiation should be added. The reactor building ventilation trip setting is 3 mR/hr, vice 10 mR/hr, and the low e

reactor water level setting is

+8", vice -8".

Pages 34 and 46 of the Primary and Secondary Containment text are attached.

Resolution:

Comment is accepted. The answer key will be changed to reflect the answers in the material for the Primary and Secondary Containment vice the answers from the reference material for SBGT system lesson plan. The total number of possible answers will be increased from five to six and the setpoints will reflect the change. The point breakdown will not be effected. The question will be reworded to reflect the six possible answers. QC.LIC-1600-1, Primary-Secondary Containment lesson plan page 34 and 46 will be added to the reference.

The original reference will be deleted due to the conflicting information.

l 2.07.b.

Facility Comment:

This question asks what may be calculated by turning the switch to COUNT. This may be answered by stating that the number of LFRMs inputting to the RBM may be calculated. Stating that 1 LPRM = 1 volt is not asked for and should not be required.

(Also applicable to requalification question 2.03) 2 1

I

~

5

Resolution:

Cross referenced to R0 2.07.b Replacement R0 2.03.b Requalification Comment accepted.

Because the HOW was not asked for, "Can be calculated by using 1 volt per operating input" will not be required for full credit. The point value for the second portion of part

'b.' will be decreased by 0.5 points. Section and test values for both the RO replacement and requalification will be adjusted accordingly.

2.09 Facility Comment:

This answer key assigns a point valve of 0.5 pts to the statement

" coolant and baron" when discussing improper mixing.

If a candidate discusses improper mixing, he should not be penalized this point value for not saying " coolant and boron", since this is implied in the discussion of improper mixing.

(Also applicable to requalification question 2.05).

Resolution:

Cross referenced to R0 2.09 Replacement R0 2.05 Requalification Comment is not accepted.

It cannot be assumed that the candidate knows what is being mixed i.e., coolant and boron or hot and cold water etc. Therefore, the answer key will not be changed.

3.07.a.

Facility Comment:

The

" Low speed limit" should not be required in this answer.

question asks for the component that is limiting and stating the

" Master Limiter" sufficiently answers this question.

(Also applicable to replacement question 6.09 and requalification question 6.06.)

Resolution:

Cross referenced R0 3.07 & SRO 6.09 Replacement SR0 6.06 Requalification Comment is accepted. The answer key will be changed to indicate that " Low speed limit" is not required for full credit. The point value is unchanged.

3.10 Facility Comment:

PCIS Group I isolation" is listed in e. of this answer and should actually appear in f. of the answer instead where PCIS actuations are asked for. (Also applicable to requalification question 3.06).

3 6

.c

Resolution:

Cross referenced RO 3.10 Replacement RO 3.06 Requalification Comment is accepted.

"PCIS Group Isolation will be moved to part f.

Also after further investigation it was noted that some of the ECCS systems had been omitted. LPCI Loop Select Logic will initiate, EDG h will start, and CS, after 8.5 minutes, will start at -59".

These three items will be added to the answer for part e.

The question point value remains unchanged. The following will be added tc the reference QC.LIC-1400 Core Spray page CS-13, QC.LIC-1000-1 RHR page 42.

3.11.b.

Facility Comment:

The exact title of this alarm tile should not be required. If a student states that the indication is an alam on his control panel that should be sufficient.

(Also applicable to replacement question 6.10 and requalification questions 3.07 and 6.07)

Resolution:

Cross referenced to R0 3.11 & SRO 6.10 Replacement R0 3.07 & SR0 6.07 Requalification Coment not accepted due to the fact that there are several alams associated with the Control Room H&V, including a major trouble alarm for the standby H&V system. Therefore, it is required the operator know this specific alarm.

4.04 Facility Comment:

This question asks for the imediate action steps that would be taken to control the reactivity addition. Parts 5 and 6 of the answer go beyond the required actions to control the reactivity.

(Also applicable to replacement question 7.04 and requalification l

i i

questions 4.04 and 7.04)

Reso1ution:

Cross referenced RO 4.04 & SR0 7.04 Replacement RO 4.04 & SRO 7.04 Requalification Coment is accepted. Due to the way the question is worded, parts 5 l

and 6 will be deleted from the answer key. The.75 points assigned to the deleted answer will be redistributed throughout the remaining t

0.25 will be added to part 3. for "even if the sequence answers.

calls for stopping at an intemediate position".0.5 will be added to part 4., 0.25 for "if a LSSS has not been exceeded and 0.25 for "if reactor power continues to increase."

j I

l 4

f

~~

3 4.06 Facility Comment:

This question asks for three actions to be performed and one of the answers listed in the key is " refer to the abnormal procedure". The actions listed in this procedure should also be considered correct.

Therefore, insert the drive to its full in position and electrically disarm the drive in and drive out solenoids should be added to the answer key. A copy of QOA 300-3 (INABILITY TO DRIVE A CONTROL ROD; UNCOUPLED CONTROL ROD) is attached. (Also applicable to requalification question 4.06).

Resolution:

4 Cross referenced R0 4.06 Replacement RO 4.06 Requalification Comment is accepted. Since the question did not specify actions required by QGP 1-2 and these two answers are Immediate Operator Actions in Q0A 300-3, these two answers will be added to the answer key for both the Replacement and Requalification exam. Point value remains unchanged.

4.08 Facility Comment:

To answer this question to the answer key req'uires, to a certain extent, the memorization of several form numbers or names that are in the rod sequence book provided to the operator. This memoriza-tion is not necessary or encouraged at QCNPS.

In answering this question the following points are provided to allow candidate responses to better be evaluated and credit given appropriately.

Copies of QTP 1600-S2 and S3 are attached as well as a copy of QGP 4-1.

1.

QTP 1600-S2 Control Rod Sequence Review Sheet is the first sheet of the rod sequence book.

If candidates describe signature requirements on the first page of the book, this is the form that is being referred to. Answers I and 2 of the answer key are affected by this.

2.

QTP 1600-53 Control Rod Sequence Sheet is the form used for the bulk of the book. Each page describes the movement of a step. This form is referred to in answer 3.

3.

A caution on page 6 and page 8 of QGP 4-1 states the NS0's responsibility in verifying proper movements and documentation.

This is accomplished on QTP 1600-S3, as described in QGP 4-1, I

and should also be considered as a correct response.

4.

QTP 1600-S1 through SS have been attached so the examiners grading these exams may better understand QCNPS's control on rod sequencing and fairly evaluate candidate responses. (Also applicable to replacement question.7.07 and requalification question 7.05) 5

^-

Ii

Resolution:

Cross referenced to RO 4.08 & SRO 7.07 Replacement SRO 7.05 Requalification i

Comment is partially accepted. The comment on the candidate memorizing from numbers is a valid point but was not required for credit. Portions of the answer not required for credit are inclosed in parenthesis, the form numbers are so marked.

Item 1 is accepted. Credit will be given if the candidate specifies "the first sheet of the rod sequence book".

Item 2 is not accepted because the question is looking for the approvals not the description of the movements of a step.

Item 3 is not accepted because the question is asking for verification before rod movement,not checks during rod movement.

Item 4 is noted.

4.09 Facility Comment:

The answer key lists the six items from QAP 300-2 but fails to include the items addressed in the note imediately after the six items. This note concerns non-professional reading material and radios or television. These should be considered appropriate answers. A copy of page 7 of QAP 300-2 is attached. (Also applicable to requalification question 4.08)

Resolution:

Comment is partially valid since the referenced NOTE gives examples-of actions which would distract the operators and is forbidden in item (3). Answer No. 3 will be modified to read as follows:

(3) Card playing, games, or other distractions from prescribed duties.

(Will also accept " reading Non-Professional reading material" or

" Utilizing unauthorized radios or TV" instead of "other distractions").

Credit will not be given for "other distractions" and the items in l

parenthesis.

I 4.12 Facility Commient:

Items 2, 6, and 7 of the answer to this question are portions of a i

group I isolation. A response of verifying a group I isolation should, therefore, be sufficient for these three items. Also, two other automatic actions occur which should be considered as correct responses even though they are not listed in this QOA. These actions are: 1) Off-gas sample vial box suction valve closes, and

2) off-gas line drain valves (5408's) close. Page 8 of the Process Radiation Monitor System text is attached. (Also applicable to replacement question 7.05.)

6 i

~ ! '

t

Resolution:

Cross referenced to R0 4.12 & SRO 7.05 Replacement Conwent is not accepted, because: One the procedure referenced does not list the automatic actions as verify a group 1 isolation and it is not assumed the candidate is aware of items 2, 6 and 7 when he/she state verify group 1 isolation. Two the alternate answers requested are not in the procedure and, therefore, will not be accepted and if list will be counted as wrong additional information.

5.07 Facility Comument:

In part a of this answer, the second sentence should not be required for full credit. The question is adequately answered with the first sentence.

In part b, the change may be attributed to an increase in slowing down length vice an increase in thermal diffusion length.

In part c, a discussion of increased leakage, due to the increased void content, is also acceptable.

(Also applicable to replacement question 1.08 and requalification questions 1.03 and 5.02)

Resolution:

Cross referenced to SRO 5.07 and R0 1.08 Replacement SR0 5.02 & R0 1.03 Requalification Cmunent is partially accepted. Comment for part a is valid and the answer key will be changed to indicate the second sentence is not required for full credit and the point value will be redistrib-uted to the remainder of the part a answer. The comment for part b is not valid, the control rods absorb thermal neutrons not intermediate neutrons as explained by the refereace material. The comment for part c is noted but no change to the answer key is required. Paraphrasing is acceptable as long as the candidate understands the effects.

5.09.a.

Facility Comment:

The term APLHGR is considered acceptable in place of MAPLHGR (actual) at QCNPS and credit should not be taken off if the term is used.

Apparently this is acceptable to the examiner since APLHGR is used in part b. of this question. (Also applicable to requalification question 5.03)

Resolution:

Cross referenced to SRO 5.09 Replacement SRO 5.03 Requalification Comment is accepted.

APLHGR will be accepted as the same meaning as MAPLHGR actual.

7 E

~

6.02 Facility Comment:

A lock-up of the pneumatic feed reg valve is affected by denergizing an air supply solenoid valve on its air supply. While a loss of power to this solenoid is not considered a lock-up signal, it will cause the valve to lock-up. Answers addressing this should not be considered incorrect. Q0A 600-2 is attached to describe this as well.

Resolution:

Coment is accepted. The answer supplied in the reference material will be added to the answer key as another required answer for full credit. The point value will be increased by 0.25 for the part of the answer and section and test point values will be adjusted accordingly.

6.04 Facility Commient:

Part a of this question should be removed from the test. The information for this question was found in the " Instructor's Personal Notes" section of the lesson plan and is presented to generate student interest in the subject only. Students are not provided with a copy of these pages.

In our course we provide students with texts of the content / skills section. Here a reference is made of these, but even at that they are not listed and only mentioned that they may be found in the FSAR. This is in the background section of the text and is not infomation a student is required to know. Pages 2 and 3 of this lesson plan are attached.

In part c of this question the first two portions are erroneous since the station has implemented the E0P's. While the lesson plan still indicates material from the former QGA's, it is not an operational guidance and the correct answer should be as directed by the QGA 100 block. The QGA direction takes precedence over anything in a lesson plan. Page 3 of QGA 100-3 is attached.

Finally, the last part of c sounds as if we have only two ARI buttons.

In fact we have two pairs of buttons, either or both pairs may be i

utilized. Actions that occur when these buttons are actuated are described in the ATWS lesson plan as referenced, however, the fact that they remain energized for 30 seconds is less significant than the action they cause. Saying that the valves remain energized for 30 seconds should not be required. Instead this credit should be placed on what occurs when the buttons are actuated to effect rod insertion. Each channel (pair of buttons) will energize three solenoid operated valves to remove air from the scram air header causing the scram inlet and outlet valves to open and instrument volume vents and drains to close. (Also applicab.le to requalification question 6.03.)

RESOLUTION:

Cross reference to SRO 6.04 Replacement SRO 6.03 Requalification 8

__--__.-.__.__.,__._._.____,,,,....__.m._.

Comments partially accepted..For part a. This comment is not accepted f

because it is stated in the lesson plan that attention will be focused l

on transient situations which have a relatively high expected frequency of occurrence.

It then states the seven transients listed in the answer key are the ones that attention will be focused on. This is considered part of the design bases for the ATWS system. For part c., regarding the first two portions this comment.is not accepted because QGA 100 states the same information. However, the point distribution will be As to changed due to examiners error in locating the partial credit.

the comments on the last part of c, they are partially accepted. That The portion referring to the implication of only two valves is wrong.

question did not ask how many pushbuttons are available but how it is initiated, and this is where two pushbuttons must be depressed, for a division, simultaneously. The portion regarding the " energized for 30 seconds" is accepted and will not be required for full credit. The portion regarding the expected actions is accepted. The following will be added to the answer key for part c and will be required for full credit: "To remove air from the scram a r header and cause the i

scram inlet [0.25] and outlet valves to open [0.25] and the instru-ment volume vent and drains to close [0.25]." The question and section point valves will be adjusted accordingly. Page 2 will also be added to the reference.

6.06 Facility Comment:

If this question is to be kept in an exam bank, the term " bypass" in part c should be changed to " equalizing" to be more consistent with QCNPS terminology and to prevent future examinee confusion.

(Also applicable to requalification question 6.04.)

Resolution:

Cross referenced to SRO 6.06 Replacement SR0 6.04 Requalification Comment noted. The word bypass will be replaced with equalizing to eliminate future confusion.

lI 6.07.b.

Facility Comment:

Most examinees will interpret this question as a norwal power reduction of 10% power.

In this case the EHC system will respond to produce the following correct answers:

1.

40%

2.

932 psig 3.

1800 RPM 0%

4.

5.

40% (Not applicable to requalification question 6.05.)

These answers are correct and should be accepted. Due, however, to interaction with the examiners, some examinees may have responded as described in the key. For this reason these answers should be 9

m a

--,--e----e-,,-.-,e--------ww---,

--w--------

-m-


,g g-

acceptable for full credit with the exception of b.2.

In this case, the reactor pressure would remain at 935 psig. The close biase is not significant enough to retard the opening of the bypass valves to cause reactor pressure to increase as described in the answer key.

This scenario however, does not depict nomal QCNPS operation since it assumes the plant is not paralleled into the Commonwealth Edison System, thereby allowing drastic turbine RPM changes.

(Also applicable to requalification question 6.05.)

Resolution:

Cross referenced to SRO 6.07 Replacement SRO 6.05 Requalification Coment is accepted. Due to the confusion of the candidates on this question the question will be graded in accordance to the candidates assumptions.

If the candidate answers assuming load rejection the existing answer key will be utilized, if the candidate assumes a power reduction than the facility 2nswers will be used.

If the candidate assumes the unit is still paralelled with another facility an additional answer will be generated and added to the key.

Additionally the word " reduction" will be replaced with " reject" and a statement of the only unit on the grid will be added to the question preface. The point value remains unchanged.

7.01.b.

Facility Coment:

Some students may have responded that the first choice for drywell temperature is from the SPDS (Safety Parameter Display System) vice the process computer. This is an acceptable answer because the SPDS drywell temperature is from those two computer points.

(Also applicable to requalification question 7.01.b.)

Resolution:

Cross referenced to SRO 7.01 Replacement SR0 7.01 Requalification Coment accepted. SPDS will be added to the answer key for an alternate answer to this question. No change to the point value is required.

f

(

7.09 Facility Coment:

Pressure should also be an acceptable answer to a.1. of this question. This exact scenario has been encountered at QCNPS before and the pressure increase has beet: noted. This is also addressed in the very paragraph of QOP 1000-5 that this question was taken from.

Page 2 of this procedure is attached to show this.

(Also applicable to requalification question 7.06.)

i l

l 10 l

x -- --..

Resolution:

Cross referenced SR0 7.09 Replacement SR0 7.06 Requalification Coment is not accepted. Pressure or re-pressurization will not work in the statement made in the question. The procedure states after re-pressurization has occurred to monitor for metal temperature in-crease etc., then stratification is present. Therefore, repressuriza-tion i In part a of this question, high pressure scram should be considered a correct response. This LSSS is listed directly next to the high pressure safety limit and does apply to it. This is shown on page 1.2/2.2-1 of the technical specifications, which is attached.

Concerning the relief valves, the relieve valves are provided to prevent the over pressurization of the vessel. These valves are sized to prevent lifting the safeties when the turbine trips from full power and the bypass valves fail to open. With this in mind, an examinee could easily be misguided by the wording in part b. of this question which asks for a " backup" to the protective actions in For these reasons, relief valves should be an acceptable answer a.

in a., if the safeties are identified in b.

To verify this refer to page 8 of the Main Steam System text and page 1.2/2.2-2 of technical specifications, which are attached.

(Also applicable to requalifica-tion question 8.02.)

Resolution:

Cross referenced to SR0 8.02 Replacement SR0 8.02 Requalification Comment is accepted. Any two of the three scrams now listed in the answer key will be accepted for the answer to part a.

If high pressure scram is listed in part a, then credit will be given for relief valves in part b.

8.03.a.

Facility Comment:

With regard to the station manajement approval, this answer is correct with respect to technical specification 6.2.d.

It should be noted, however, that QAP 1100-7 gives guidance in obtaining approval for a temporary procedure change and is more restrictive.

Either answer should be acceptable since no reference was given in the question. A copy of QAP 1110-7 and QAP 1100-T1 are attached.

Also concerning this question, two items are asked for. The approval discussed above is one, however, the review required by On-Site Review and the approval by the Station Manager should be treated as two separate items, with either or both being acceptable.

Again, see attached copy of QAP 1100-7.

11

~

Resokution:

The comment is accepted.

In Ifeu of the procedure supplied by the facility, that was not originally supplied to the. examiners, the answer key need not be changed because the administrative procedure is more detailed than the answer key and T.S. as originally referenced.

The answer key will be changed, however, in that instead of two possible answers the answer key will be broken down into three possible answers separating On-Site review and Station Superintendent as two possible answers. No change to the point breakdown is needed.

8.04 Facility Comment:

In this This question does not specify a procedure or circumstance.

light, several other answers should be acceptable as indicated below with their references. These references are attached.

1.

Any GSEP condition: reference QAP 300-2 page 11 2.

Flooding: reference 00A 010-4 page 2 3.

Fire: reference QEP 340-5 page 3 4.

Scram: reference QAP 300-1 page 5 5.

When relieving" the SCRE during normal plant operation:

reference QAP 300-1 page 6.

(Also applicable to requalification question 8.03)

Resolution:

Cross referenced to SRO 8.04 Replacement SRO 8.03 Requalification Comment is accepted. The additional five conditions will be added to the answer key.

The five procedures listed will be added to the reference. The point breakdown remains unchanged.

8.06 Facility Cassent:

This question references QAP 300-3 which in turn references Technical Specifications figure 6.1-3, both of which are attached.

While these differ slightly either should be acceptable.

(Also applicable to requalification question 8.04)

Resolution:

Cross referenced SR0 8.06 Replacement SRO 8.04 Requalification Comment is not accepted, because the Technical Specifications do not address the position as required and the question ask for "at normal power conditions" not with "there is fuel in both reactors."

12

a 8.08 Facility Comment:

Initial license candidates are not given specific instruction on 10 CFR 55. At QCNPS, individual licensees do not control these aspects of their licenses.

Instead, this is considered an administrative requirement that is enforced by plant management when such a situation arises. A great deal of similar detailed requirements exist on licenses and renewals that are not considered individual licensee responsibilities at QCNPS, instead, the training, administrative and operating department management ensure all requirements are met. This should be taken into consideration when grading this question.

(Also applicable to requalification question 8.06)

Resolution:

Cross referenced to SR0 8.08 Replacement SR0 8.06 Requalification Comment is accepted.

Since the facility does not hold the candidates responsible for this license condition this question will be deleted from both the replacement and requalification exams and point values adjusted to reflect the deletion.

8.11.a.

Facility Comument:

Full credit should be given to an answer that adequately describes the difference between the cards. Detailed color and border schemes should not be required.

Resolution:

Comment is accepted, because paraphrasing is acceptable as long as the candidate describes the card in sufficient detail to answer the question.

I t

i 4

13 4

I_

4 e

U. S. NUCLEAR REGULATORY COMMISSION REACTOR OPERATOR REQUALIFICATION EXAMINATION FACILITY:

QUAD CITIES 1&2 3

i y

n

)

REACTOR TYPE:

BWR-GE3 e

l i

V DATE ADMINSTERED:

86/10/14 EXAMINER:

MORGAN. T.

CANDIDATE INSTRUCTIONS TO CANDIDATE:

Read the attached instruction page carefully.

This examination replaces the current cycle facility administered requalification examination.

Retraining requirements for failure of this examination are the same as for failure of a requalification examination prepared and administered by yo-training staff.

Points for each question are indicated in pa. atheses after the question.

The passing grade requires at least 70%

in each category and a final grade of at least 80%.

Examination papers will be picked up four (4) hours after the examination starts.

% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY Z4.17

15. QfL_.

2i.57 5.

THEORY OF NUCLEAR POWER PLANT OPERATION, FLUIDS,AND THERMODYNAMICS 25.42.

15.00-24.07 6.

PLANT SYSTEMS DESIGN, CONTROL, AND INSTRUMENTATION 2.4 7 9 3 15.00

-24.53 7.

PROCEDURES - NORMAL, ABNORMAL, EMERGENCY AND RADIOLOGICAL CONTROL l

IC CO 2 4.'79 #

- 10. CC -

26--23 8.

ADMINISTRATIVE PROCEDURES, CONDITIONS, AND LIMITATIONS G O. : a

41. W Totals E

All work done on this examination is my own.

I have neither given nor received aid.

Candidate's Signature

. ~~..

~

NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:

1.

Cheating on the examination means an automatic denial of your application and could result in more severe penalties.

2.

Restroom trips are to be limited and only one candidate at a time may leave.

You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.

3.

Use black ink or dark pencil only to facilitate legible reproductions.

4.

Print your name in the blank provided on the cover sheet of the examination.

5.

Fill in the date on the cover sheet of the examination (if necessary).

6.

Use only the paper provided for answers.

7.

Print your name in the upper right-hand corner of the first page of each section of the answer sheet.

8.

Consecutively number each answer sheet, write "End of Category __" as appropriate, start each category on a new page, write only on one side of the paper, and write "Last Page" on the last answer sheet.

9.

Number each answer as to category and number, for example, 1.4, 6.3.

10. Skip at least three lines between each answer.
11. Separate answer sheets from pad and place finished answer sheets face down on your desk or table.
12. Use abbreviations only if they are commonly used in facility literature.
13. The point value for each question is indicated in parentheses after the question and can be used as a guide for the depth of answer required.
14. Show all calculations, methods, or assumptions used to obtain an answer to mathematical problems whether indicated in the question or not.

l

15. Partial credit may be given.

Therefore, ANSWER ALL PARTS OF THE QUESTION AND DO NOT LEAVE ANY ANSWER BLANK.

16. If parts of the examination are not clear as to intent, ask questions of the examiner only.

I

17. You must sign the statement on the cover sheet that indicates that the work is your own and you have not received or been given assistance in completing the examination.

This must be done after the examination has been completed.

,,m_m

18. When you complete your examination, you shall:

a.

Assemble your examination as follows:

(1)

Exam questions on top.

(2)

Exam aids - figures, tables, etc.

(3)

Answer pages including figures which are part of the answer.

b.

Turn in your copy of the examination and all pages used to answer the examination questions.

c.

Turn in all scrap paper and the balance of the paper that you did not use for answering the questions.

d.

Leave the examination area, as defined by the examiner.

If after leaving, you are found in this area while the examination is still in progress, your license may be denied or revoked.

l l

l l

l

l l

5, THEORY OF NUCLEAR POWER PLANT OPERATION.

Paco 4

FLUIDS.AND THERMODYNAMICS QUESTION 5.01 (3.00) 1 Describe HOW and WHY a centrifugal pumps discharge head is affected for each of the following.

(Consider each condition seperatly and assume NPSH is maintained in all cases.)

a.

Suction pressure increases.

b.

The discharge valve is throttled closed.

c.

The temperature of the fluid being pumped increases.

QUESTION 5.02 (3.00)

Explain HOW and WHY Rod Worth changes for the following conditions.

a.

Rod Worth of a center rod compared to a peripheral rod at 50 percent power.

b.

Rod Worth when plant conditions change from cold to hot at 1 percent power.

c.

Rod Worth when plant conditions change from hot at 1 percent power to hot at 100 percent power.

QUESTION 5.03 (2.00)

Your reactor operator informs you MAPRAT is 1.02.

a.

Is the MAPRAT, as stated, conservative?

Explain your answer.

(1.0) b.

In regards to MAPRAT which of the following statements are TRUE and which are FALSE?

1.

MAPRAT maintained within limits ensures transition boiling will not occur in 99 percent of the fuel bundles. (0.5) 2.

Maintaining MAPRAT limits ensures the APLHGR limits are met (0.5).

(***** CATEGORY 5 CONTINUED ON NEXT PAGE *****)

4 e

y-a

+-,

v-e.--

y,, -

,--e m

,--wm

-e-.i.--

,y,,-

ww.-

--y_-

-.--,--wey.,m.%

y-

+ -

--m-y

5, THEORY OF NUCLEAR POWER PLANT OPERATION.

Pcga 5

FLUIDS.AND THERMODYNAMICS QUESTION 5.04 (2.00)

The reactor is exactly critical LOW in the intermediate range.

A control rod is withdrawn one notch.

a.

Describe what happens to indicated neutron level AND why?

(Continue your discussion until a steady state condition is reached.

Assume no futher operator action other than ranging the IRM meters.

(No other parameters are changed.)

b.

Describe how reactor period would respond AND why?

(Continue your discussion until a steady state condition is reached.

Assume no futher operator action other than ranging the IRM meters.

(No other parameters are changed.)

QUESTION 5.05 (1.50)

What are THREE of the design or operational factors that insure adequate Net Positive Suction Head (NPSB) for the recirculation pumps?

(***** CATEGORY 5 CONTINUED ON NEXT PAGE *****)

-.--r

,n

,m--,

s_--,y

5.

THEORY OF NUCLEAR POWER PLANT OPERATION.

Pega 6

FLUIDS.AND THERMODYNAMICS QUESTION 5.06 (1.50)

MATCH the appropriate THERMAL LIMIT (a-c), to each FAILURE MECHANISM AND to each LIMITING CONDITION given below:

THERMAL LIMIT a.

Linear Heat Generation Rate (LHGR) b.

Average Planar Linear Heat Generation Rate (APLHGR) c.

Minimum Critical Power Ratio (MCPR)

FAILURE MECHANISM LIMITING CONDITION F1.

Clad melting caused by L1.

Coolant transition decay heat & stored heat boiling following a LOCA F2.

Clad cracking from the surface L2.

Clad plastic strain becoming vapor " blanketed"

< 1%

F3.

Clad cracking caused by L3.

Maximum clad temp-high stress from pellet erature of 2200 deg F expansion QUESTION 5.07 (2.00) i The reactor has operated at 70% power for several weeks.

Power is then increased to 95% ot9 rated using the recirculation system.

I Describe the changes operators would have to make to recirculation flow over the next two days in order to hold reactor power at 95%

of rated.

Include WHEN the changes would have to be made and WHY.

i l

l t

l l

l

(***** END OF CATEGORY 5 *****)

n g

,.---7, m-,.---g y-p

6.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Paco 7

QUESTION 6.01 (2.00)

For each of the following, state whether a ROD BLOCK, HALF-SCRAM, or NO REACTOR PROTECTION SYSTEM ACTION is generated for that condition.

NOTE:

If two or more actions are generated, i.e.,

rod block and half-scram, state the most severe, i.e.,

half-scram.

a.

APRM

'B' downscale, Mode Switch in Run b.

12 LPRM inputs to APRM

'C',

Mode Switch in Startup c.

Flow units

'A' and

'B' upscale (less than 108 percent flow) Mode Switch in Run d.

Reactor water level 55 inches, Reactor power 18 percent, Mode Switch in Run.

QUESTION 6.02 (1.00)

For each of the areas listed choose which type of fire protection system protects it.

AREA FIRE PROTECTION SYS

a. Computer Room
1. Halon 1211
2. Halon 1301
b. Recirc MG Set Room
3. Wet Pipe
4. Deluge (Dry pipe)
c. Diesel Generator Room
5. Preaction
6. Foam Suppression
d. Main Transformer
7. Cardox l

i

(*****

CATEGORY 6 CONTINUED ON NEXT PAGE *****)

6, PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Paga 8

i f. 2)

QUESTION 6.03

(-2-59t With regard to an Anticipated Transient Without a Scram (ATWS) protective system, it is stated "All of the anticipated transients, which require mitigation in the unlikely event of an ATWS, quickly reach at least one of the two conditions which are readily sensed and from which mitigated actions may be initiated."

a.

WHAT are four of the seven anticipated transients which require mitigation?

(1.0) b.

WHAT are the two conditions that will automatically initiate mitigating actions and WHAT are their setpoints?

(0.5) c.

WHEN will this system be MANUALLY Initiated, How is it manually initiated.,and WHAT is expected to occur wnen manually initiated?

(4,6%- (1. 5 )

QUESTION 8.04 (3.00)

MULTIPULE CHOICE For each of the failures listed below choose the most correct answer.

Assume the failure exists at the time an automatic initiation signal is received for the High Pressure Coolant Injection System.

Consider each failure separately.

Assume normal 100% plant temperature and pressure.

FAILURES a.

Auxiliary Oil Pump Shaft is seized. (Pump will not rotate.)

b.

The Motor Gear Unit is failed at its' Low Speed Stop.

Ap> 4 t od c.

Thesbrrres valve is open on the flow detector that feeds the Flow Controller.

CHOICES 1.

HPCI will initiate and go to its runout condition (Maximum flow).

2.

HPCI will initiate and inject as it is designed. (Normal flow).

3.

HPCI will initiate but will not inject any water. (No flow) 4.

HPCI will not initiate automatically or manually. (Does not start) l

(***** CATEGORY 6 CONTINUED ON NEXT PAGE *****)

i

8.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Pago 9

QUESTION 6.05 (2.50)

The plant is operating at 50% power when a load reduction occurs which is equal to 10% power.

There is an EHC diagram at the end this examination for reference.

a.

Indicate which of the following EHC setting (s) are NOT at their normal setting for this plant condition.

(0.5) 1.

Load Selector 9 100%

2.

Load Limit 9 100%

3.

Max Combine 9 105%

b.

What would be the final condition /value for each of the initial parameters listed below.

(Assume the EHC settings in part a.)

(4 9 0.5 ea) 1.

Reactor Power 50%

2.

Header pressure 935 psig 3.

Turbine Speed 1800 rpm 4.

Bypass Valves 0 valves open QUESTION 6.06 (2.00)

Refer to attached Figure 5, Recirculation Speed Control Network, for the following:

a.

The plant is operating at 30% power with both recire pump M/A transfer stations in MANUAL.

FOR EACH of the following instances, INDICATE HOW the speed of Recire Pump

'A' would change (Increase, Decrease, or Remain the Same) AND WHICH components (s) of the control system is(are) limiting.

(1.0) 1.

Recirc Pump A' M/A transfer station is placed in ' AUTO'.

2.

The generator speed tachometer output feedback signal fails low due to a loss of continuity through the field breaker contact.

b.

WHAT action must be taken by the control room operator prior to resetting a ' LOCKED OUT' scoop tube?

WHY?

(1.0)

I

(***** CATEGORY 6 CONTINUED ON NEXT PAGE *****)

r w

i,-

m

-w.yvw.--,2,

-w g.

g.-m-y.-------.

r.--m


v--

~

6.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Fece 10 QUESTION S.07 (2.00)

The control room emergency zone is protected against some toxic gases by a control room HVAC System isolation.

a.

WHAT gases are monitored by this isolation system (1.0) b.

WHAT indication is available to alert the operators the isolation system has actuated?

(0.50) c.

HOW is the control room emergency zone protected against toxic gases, that are not monitored by the Automatic Isolation System.

(0.50) 1 l

(***** END OF CATEGORY 6 *****)

l l

a 7,

PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Paga 11 AND RADIOLOGICAL CONTROL QUESTION 7.01 (2.00)

Answer the following questions concerning the seven caution notes associated with the QGA (Symptom oriented procedures),

a.

Complete the sentence according to general caution #1; "If an entry condition for a QGA procedure occurs, enter that procedure irrespective of whether that pt"ocedure..."

(0.5) b.

According to caution #3, HOW is the Drywell temperature determined?

(Include order of preference.)

(1.0) c.

As discribed by caution #5, EXPLAIN when Yarway indicated levels are not reliable and WHICH level instrument should be used in its place?

(0.5)

QUESTION 7.02 (2.50)

What are the entry conditions for QGA-200 Primary Containment Procedures.

(Five required for full credit with parameter values.)

QUESTION 7.03 (2.00)

According to QOA 202-1 " Jet Pump Failure", there are two indications or symptoms where simultaneously occurring would indicate a failure of a jet pump.

WHAT are these two indications?

(Be specific, include setpoints if needed.)

QUESTION 7.04 (2.50) i If while operating at 95% power, with EGC in operation, an

'A' heater high level alarm and a step increase in APRM readings are received.

WHAT Immediate Action Steps would be taken to control reactivity addition?

(Limit your answer to the immediate action steps required l

by QOA 400-1 " Reactivity Addition")

(An action step may contain more l

than one action item.)

l 1

{

(***** CATEGORY 7 CONTINUED ON NEXT PAGE *****)

i i

{

7.

PROCEDURES - NORMAL. ABNORMAL. EWRGENcV Page 12 AND RADIOLOGICAL CONTROL QUESTION 7.05 (2.00)

QGP 4-1, Control Rod Movements and Control Rod Sequences, specifies the NSO's responsibility in regard to use of the Control Rod Sequence Package prior to normal in-sequence control rod movements.

JAc LISTraee four items the NSO must verify prior to commencing normal in-sequence control rod movements? (An item may consist of more than one action.)

QUESTION 7.06 (2.00)

If operating in shutdown cooling and both recire pumps are lost, QOP 1000-5 (SHUTDOWN COOLING START-UP AND OPERATION) states to monitor for temperature stratification.

Stratification is indicated by increasing (A.1.) without a corresponding (A.2.) or (A.3) change.

a.

List parameters A.1.,

A.2.,

and A.3.

(0.75) b.

List five of the suggested actions to minimize stratification if both recirc pumps are off.

(1.25)

QUESTION 7.07 (2.00)

QGP 2-3, Reactor Scram procedure prerequisites states "If sufficient time is availabe, before scramming the reactor, perform one or more of the following:"

One of the Prerequisites is "If the unit is operating in EGC, trip EGC t

l and return recirculation flow control.to Manual."

WHAT are the four remaining action steps that should be performed prior to scramming the reactor?

(An action step may contain mere than one action item.)

l I

(***** END OF CATEGORY 7 *****)

,w

8, ADMINISTRATIVE PROCEDURES, CONDITIONS.1 Paga 13 AND LIMITATIONS QUESTION 8.01 (1.00)

According to QGP 1-1, Normal Unit Startup, if a procedure is terminated at any time during its execution, several administrative requirements must be met.

List four of these requirements that must be performed.

QUESTION 8.02 (1.50)

Per the Technical Specifications Limiting Safety System Settings; SETPOINTS NOT REQUIRED.

a.

WHAT are two protective actions designed to prevent exceeding the Reactor Coolant System pressure safety limits?

(1.0) b.

WHAT is the protective action that is provided as a backup for the two protective actions in "a." above.

(0.5)

QUESTION 8.03 (2.00)

Under WHAT four conditions will the Shift Engineer accept direct responsibility for the activities and operations in the Control Room?

QUESTION 8.04 (2.00)

According to QAP 300-3, Shift Manning procedure, each operating shift for Units 1 and 2 normally consists of WHAT man power for normal l

power conditions?

(Include the number of people for each position and type of license, if one is required.)

(***** CATEGORY 8 CONTINUED ON NEXT PAGE *****)

w,~

c.

ADMINIOTRAUVE PROCEDURES. CONDITIONS.

Page 14 AND LIMITATIONS x

g QUESTION 8.05 (1.50) a.

What action is required by any individual who exceeds his approved -

exposure limit at Quad Cities Station?

(0.5) b.

What are the 10 CFR limits for; 1.

whole body exposure (assume NRC-4 compl6ted)?

2.

skin of whole body?

3.

hands and feet?

(3 @ 0.25 ea) c.

TRUE or FALSE

~

Pocket type direct reading dosimeters are used to furnish the exposure data for'the 10 CFR limits.'

(0.25)

~

QUESTION 8.0S (1.00)

In-accordance with 10 CFR 55, " if a licensee has not been actively perfo'rming the functions of an operator or senior operator for a period ofx-----7-----umonths, or longer, he shall, ' prior to resuming activities li, censed pursuant to this part, demonstrate to the Commission that his knowlcidg'ri and understanding of f acility operation and administration ~are satisf actory. "

Select from the below list the eprrect answer to complete the s

above statement.

a.

2

N

~ ' ~

r b.

4 A

W.L5h

'Q 1' "

c.

G d.

12

/ '

f s

4 s

(***** CATEGORY 8 CdN1'INUED ON NEXTSPACE *****)

I e

-y, y

e.-,

-.,.r

8.

ADMINISTRATIVE PROCEDURES. CONDITIONS.

Para 15 AND LIMITATIONS QUESTION 8.07 (1.50)

I i

According to the General Limiting Conditions for Operation Technical Specifications 3.0/4.0 it states:

"When a system, subsystem, train, component, or device is determined to be inoperable solely because its emergency power source is inoperable, or solely because its normal power source is inoperable, it may be considered OPERABLE for the purpose of satisfying the requirements of its applicable Limiting Condition for Operation, provided:

a.

WHAT additional conditions must be met inorder to satisify this limitation?

(1.0) b.

WHAT plant modes of operation does this Limiting Condition for Operation NOT apply?

(0.5)

QUESTION 8.08 (2.50)

)

Regarding Unit 2's Technical Specification on Recirculation Pump Flow Mismatch:

a.

What is the allowed mismatch between the recirculation pumps?

(Include parameters and limits for the full spectrum of operations.)

[1.5]

b.

What is the required action if the above Limiting Condition for Operation can not be met?

[0.5]

c.

What is the basis for this Limiting Condition for Operation?

[0.5]

4 QUESTION 8.09 (1.00) l Unit 2 Technical Specifications require that the coupling integrity of a Control Rod be demonstrated by withdrawing the rod to the Fully Withdrawn position and verifying that the rod does not go to the overtravel position.

LIST two circumstances under which the Technical Specifications REQUIRE that this coupling check be performed.

(***** CATEGORY 8 CONTINUED ON NEXT PAGE *****)

6 w


,m


_a.

-.,.,.r-,-

--.7,--

8, iADMINISTRATIVE PROCEDURES. CONDITIONS.

Pago 16 AND LIMITATIONS QUESTION 8.10 (2.00)

According to a HOTE in the Conduct of Shift Operation QAP-300-2 it

/

states, "If an emergency situation should arise prudence may require allowing a Unit Operator to leave the 'at the controls' of his/her

' Stable and under control reactor' to help."

a.

A Quad Cities operator is considered 'At the Controls' when he/she is in WHAT area?

(0.5)

+

b.

These emergency situations are defined as rare and serious circumstances which if uncorrected could result in, WHAT three items?

(0.75)'

c.

The control room supervisor may authorize a Unit Operator to leave his 'At the Controls' if his/her ' Stable and under control reactor' to help on the other Unit, only if WHAT three conditions are met?

(0.75) l 1

(***** EdD OF CATEGORY 8 *****)

(********** END OF EXAMINATION **********;-

,-_m

__,.-.,r.

_y_

F.QUATION SHEET f = ma v = s/t Cycle efficiency = "E 2

v = ms s = v,e +

lac s

E = mC a = (v, - y )/t 2

A = A,e" E gg. 4 vg=v +a A = AN PE = mgh w = e/t A = In 2/eq = 0.693/tg W = v4P-e (eff) = (t,:)(ts) q AE - 9314m

(

+

)

Q = M AT I. I.4X P

e o

', Q = UAAT I. I. UX

~

'Pur = W m'

-X h g

I.I to g

SW(t).

TVI. = 1.3/u y.p lo o.t/T HVI.

  • 0.693/u y.p

'SUR = 26.06/T

~

T = 1.44,DT SCR = S/(1 - K,gg)

/A*,o)

SUR = 26 CR = S/(1 - K,gg )

g x

1(

eff)1 "

2(l Eeff)2 T = '(1*/o ) + [(i 'o)/A,gg ]

o 7. g*/ (, _ g M = 1/(1 - K,gg) = CR /CR g

0 I"( ~ 8) A eff M = (1 - K,g,)0 (1 - K,gg)g

/

a = (K,gg-1)/K,gg = AK,ff/Keff SDM = (1 - K,gg)/K,gg (L*/TK,'gg -) + @/(1 + A,gg )]

1* = 1 x 10 seconds

~

i p=

P = I4V/(3 x 1010)

~I A,gg = 0.1 seconds A

I = Na Idty=Id22 UATER PARAMETERS Id =Id g

2 2

1 gal. = 8.345 lba R/hr = (0.5 CE)/d (meters) 1 gal. = 3.78 liters R/hr = 6 CE/d (feet) 1 ft = 7.48 gal.

MISCEI.L\\NEOUS CONVERSIONS 3

10 Density = 62.4 lbm/ft i Curia = 3.7 x 10 dps Density - L gm/cm I kg = 2.21 1ha 3

i Hest of vstori:scioni = 970 reu/lbm 1 hp = 2.54 x 10 BTU /hr 6

Hest of fusica = 144 Beu/lba 1 Mw = 3.41 x 10 Beu/hr 1 Atm = 14.7 psi = 29.9 in, l'g.

1 Btu = 778 f t-lbf 1 ft. H O = 0.4333 lbf/in 1 ' inch = 2.54 cm 2

F = 9/5 C + 32

  • C = 5/9 ( F - 32)

""E soc tasmofE CoNTICQ c

I man EEEm g

A M CoNTRoLLia O

I O

MASTR O

To r too, span connot "

A M /^

nacaC Loop

",A." o Co,on.

-m s

s7A73eN DUAL PUNCTION L,

use s

_L____

I cosmo wues oncHAnoa vavi puu. open sTAar saan 0

ee=Aion nos sygm (m O

30%

_._ cosso wuaN F.W.

stow >207.

I L.,

'T l

96v-

_Y esca ce= Atom

_,y I

o uMTWO NETwomK spam

.-y T

sGNE

' ~

l v

~

de.c.

  • ) -wyu v.w sy g l'

o c:nnnoust wucum "T", C.NTACT5 N Toa swown pom ruto sepam ope

  • i pensAcx i

I F-------"

O" 88""

posmona A

CA Q

7A M

Ampunu t

9 f

scoe, post l

naus runa Figure 5. Recirculation Speed Control Network REV 1 1 'l t & 3_

l START UP RAiE SPEED OPEN BIAS "O"

INIERCEPI J/de

~ 2

[

4

)

=Y V

A VALVE g IV REGULAllON l

DEMAND A

% FLOW

  • J i

tuesmE -

I SPEED 1

SPEED v

IY EIO

{

SELECT q-g I

I L

SWIICH LOAD REMCI i

suaalNE - -

SPEED REMOIE INC/DEC SIGNAL "O"

' +

EseOs i

SPEED g

0 CV REGULAllON _

y

+

LOAD SELECTOR

+

% fL O W NC 1

g.J START UP RAig MA LW gg U

J L RUNSACK ON LOAD REMCT l

10 RECIRC 4 h-AUNSACK, SYNC $ PEED HOI SELECIED FLOW I f ll d

h BUNSACK ON LO55 Of STATOR COOLING et uO.2 SiOP

.Z-a, fROM SPEED SELECiOR -

Z VALVE SIEAM DEMAND THAOIILE FRE55USE TUSSINE stiPPED gg,

h"O" Op.i PaE55 II CONIROL

- [yo-h* MOI SIAS yagyg y

PRE 55URE SET a L

% FLOW MAXIMUM

~

DEMAND "O..

Z UNI LOAD

. -i TRWED BYPASS l

SIAS

~

l STEAM

'I

' 2 E IV VG VALVE I

DEMAND j

HiaolitE SMALL PRE 550sE

,,0" J CLOSE SYPA55 JACK I LOW VACUUM

]

.8A5 l

Figure 6. Speed and Acceleration Control Unit i

5.

THEORY OF NUCMAR POWER PLANT OPERATION.

Paco 17 FLUIDS.AND THERMODYNAMICS A

g fW53 p.e :y, r L 31, d :. 1 ANSWER 5.01 (3.00) a.

Head increases [0.5] the pump is still putting the same amount of work into the fluid, therfore the same delta pressure across the pump, so as the suction pressure increases so will the discharge head [0.5]

b.

Head increases [0.5] as system resistance to flow increases, pump head increases [0.5]

c.

Head decreases [0.5] as temperature increases, system resistance l

to flow decreases (lower viscosity), therfore head decreases [0.5]

REFERENCE l

HTFF, page 25 Quad Cities, Heat Transfer and Fluid Flow Pump Characteristics, pg 6 6-105 ANSWER 5.02 (3.00) a.

Control rods in the center of the core are exposed to a higher thermal flux than those at the core periphery and, therefore, have a greater worthvEpzfh. (Rod worth would be increased anywhere in the core where a'fadial thermal neutron flux peak existed even if it were an edge rod)[0.5]?

b.

As moderator temperature increases, its density decreases resulting in longer thermal diffusion lengths.

This allows thermal neutrons to travel further and be absorbed by the rod; [0.5] thus, rod worth increases with an increase in moderator temperature [0.5].

c.

As voids increase, again less moderations takes place.

Again, thermal neutrons travel further; however, voids tend to depress thermal flux because of the very poor moderation [0.5].

Thus, as voids increase, rod worth decreases [0.5].

REFERENCE QC Reactor Theory, pages 58 and 60

(***** CATEGORY 5 CONTINUED ON NEXT PAGE *****)

5.

THEORY OF NUCLEAR POWER PLANT OPERATION.

Pega 18 FLUIDS.AND THERMODYNAMICS l

ANSWER 5.03 (2.00) a.

The MAPRAT of 1.02 is not conservative (0.5].

With a MAPRAT greater than one it means that the MAPLHGR has been exceeded because:

o'.

or MAPRAT =,MAPLHGR,(actual)/MAPLHGR (LCO)

(Actual formula is not required but the relationship explained is.) [0.5]

b.

1.

False 2.

True

[2 0 0.5 ea]

REFERENCE HTFF, page 31 Quad Cities Heat Transfer and Fluid Flow pg 9-24a ANSWER 5.04 (2.00) a.

Neutron level would start and continue to increase [0.25] until the point of adding heat is reached [0.25].

As the coolant heats up, negative reactivity is added and power turns [0.25].

Power would stablize at the point of adding heat (0.25].

b.

Period would take a step jump due to the production of prompt neutrons [0.25].

Immediately after this step, the rate of power change decreases to a rate controlled by delayed neutrons until the reactivity is no longer being increased [0.25].

Then a sharp drop would occur as the rate of reactivity addition drops to zero [0.25].

A stable period would continue until negative reactivity is inserted.

Stabilize:3 at infinity [0.25].

REFERENCE Dresden NUS Theory Quad Cities Theory Review pages 44-45 and 78.

(***** CATEGORY 5 CONTINUED ON NEXT PAGE *****)

1 5.

THEORY OF NUCMAR POWER PLANT OPERATION.

Prco 19 FLUIDS.AND THERMODYNAMICS ANSWER 5.05 (1.50) 1.

They are physically located as far below the normal water line as possible to provide the greatest static head.

2.

With feed flow less than 20% they are kept on minimum speed.

3.

At high power operation adequate NPSH is obtained from feedwater subcooling.

4.

Lou reactor Vessel water level trip, cavitation interlock.

5.

Suction valve closed trip, cavitation interlock.

[3 0 0.5 ea]

REFERENCE DRESDEN - Recirc System Lesson Plan pg 16 & 18 GE Thermodynamics, Heat transfer & Fluid Flow, page 7-93 & 94 Quad Cities LIC 0202-1 pg 19 and 21 ANSWER 5.06 (1.50)

a. F3. [0.25] L2. [0.25]
b. F1. [0.25] L3. [0.25]
c. F2. [0.25] L1. [0.25]

REFERENCE EIH:

GPNT, Vol VII, Chapter 10.2-23 Quad Cities Heat transfer and Fluid Flow pg 9-16a, 9-19a, and 9-34a ANSWER 5.07 (2.00)

During the first 4 - 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> (0.33) recirculation flow would have to be decreased (0.34) to compensate for the decrease in xenon concen-tration (0.33).

During the remainder of the transient, recirculation flow would have to be increased (0.34) as xenon builds up to its equilibrium value (0.33) over the next 40 - 50 hours5.787037e-4 days <br />0.0139 hours <br />8.267196e-5 weeks <br />1.9025e-5 months <br /> (0.33).

REFERENCE GE Reactor Physics Review, pg 45 Quad Cities Reactor Theory, Fission Product Poisons, pg 68 and 70

(***** END OF CATEGORY 5 *****)

6.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION P gn 20 l

ANSWER 6.01 (2.00) a.

Rod Block b.

Half-Scram c.

- ?cd 21a&

l'h /j** S'.' n D "

  • / ' ' ' ~

d.

No Reactor. Protection System Action

[4 4 0.5 ea]

REFERENCE Quad Cities RPS and APRM Lesson Plans ANSWER 6.02 (1.00) a.

- 2.

b. - 6.
c. - 7.
d. - 4.

[4 @ 0.25 ea]

REFERENCE Quad Cities Fire Protection Sys LIC-4100-1 pg 4, 6, 12 & 14

( 2. 00)

ANSWER 6.03

(-E-5e) a.

1.

Recirculation Flow Control failure with/ increasing flow 2.

Turbine Generator Trip 3.

Closure of all Main Steam Isolation Valves 4.

Pressure Regulator Failure in Open Direction 5.

Feed Water Controller Failure to Maximum Demand 6.

Loss of Feedwater Flow 7.

Loss of Auxiliary Power

[4 0 0.25 ea]

b.

1.

High Reactor Pressure 1250 psig [0.25]

2.

Low-Low water Level -59 inches (0.25]

c.

In the event a scram occurs or should have occurred and reactor m

power [0.25] is still above 3% or can not be determined [0.25).

It is initiated by depressing BOTH ATWS Division pushbuttons.

simultaneously [0.25]whichenergizestheARIvalves(//c for 30 seconds) [0. 25]j

/,,.,..,,,,, f,,, a r,,.,., j,,.,.,. !

r, I 4 t'='

1

~ l w e l. * > 1.

f..pD:Q e.. i 41

,. 4.

. t..u e. +.. t. s. l. -

/. : /.;. [o. r : 7

(***** CATEGORY 6 CONTINUED ON NEXT PAGE *****)

-y n

,y

6.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Pega 21 REFERENCE Quad Cities Anticipated Transient Without Scram LIC-0300-3 pg 3, 4 & 18.

ANSWER 6.04 (3.00) a.

4 b.

3 c.

1

[3 9 1.0 ea]

REFERENCE Quad Cities High Pressure Coolant Injection LIC-2300 pg 11, 12 & 31 ANSWER 6.05 (2.50) a.

1.

Load Selector ( should be 10 % above Load) [0.5]

b.

1.

Rx Pwr 9 50% G M i

~

2.

Hdr Pressv'037c03S psig%iuwr beca=

of-BPV-elose-Bias)I?b'.!

3.

1854 RPM (45' Epm to oyercome load selector 9 rpm to over come 10% load error)& -s]

4.

BPV 2 valves 100% 3rd 25% open or 2 1/4 valves openlo&7

[4 9 0.5 ea)

[qto g]

REFERENCE Quad Cities EHC Pressure Control and Logic LIC-5650-2 pg 12 - 16, 21, 22 and figure 6 QGP 1-1 Normal Unit Startup pg 17 ANSWER 6.06 (2.00)

Masterlimiter,(ioningunitorelectrical lowspeedlimit)[0.25]

a.

1.

Increase [0.25]

2.

Increase [0.25]

Scoop tube posit limit switches [0.25] w (LcG., %' Q,, '. 9r4 cr.a c.

j b.

The null voltmeter is used to match the speeB from the tachometer with the speed demand from the speed controller [0.5], to prevent i

l a flow transient during reset [0.5].

1 REFERENCE Quad Cities Recire Flow Control, LIC-0202-2, pg 10, 12, 14, & 36 QOP 202-6 Resetting Recire M/G Set Scoop Tube Rev 3 pg i l

l

(***** CATEGORY 6 CONTINUED ON NEXT PAGE *****)

l t

l

6.

PLANT SYSTEMS DESIGN. CONTROL. AND INSTRUMENTATION Para 22 ANSWER 6.07 (2.00) a.

1.

Ammonia 2.

Clorine 3.

Sulfur Dioxide

[3 9 0.33 ea]

b.

Control Room HVAC " Major Trouble" alarm.

[0.50] 5 u.'u 4 < 'rR

a M -

c.

Manual Isolation by the operator.

[0.50]

REFERENCE Quad Cities BVAC LIC-5750 pg 27

(***** END OF CATEGORY 6 *****)

4 m

-+


,,m.-.-e--

.*w

-._-,m,-

')

\\

7.

PROCEDURES - NORMAL. ABNORMAL EMERGENCY Pra 23 AND RADIOLOGICAL CONTROL i

ANSWER

' 01 (2.00) a.

"has already been executed or is presently being executed.

(Exact wording is not required for full credit) [0.5]

b.

Drywell temperature is determined by reading the following sensors.

(The sensors are listed in order of prefered use.)

1.

Process computer (point C166 (C266)) e trol Process computer (point C165 (C265));r ;r(;

2.

Valve leak recorder (260-20 pt 18) l Valve leak recorder (260-20 pt 19) 3.

Drywell Environs Indicator (5741-170 pt 36) 4.

Drywell Environs Recorder (5741-130 pt 32)

[4 sensors 9 0.2 ea = 0.8) [ Order of preference 0.2]

c.

Yarway level indicated levels are not reliable during rapid RPV depressurizatin below 500 psig [0.25].

For these conditions, utilize the GEMAC instruments [0.25] to monitor RPV water level.

REFERENCE Quad Cities QGA-00 Rev 3 Caution #1 pg 1, Caution #3 pg 2, and Caution #5 pg 3 ANSWER 7.02 (2.50) 1.

Suppression Pool Temperature above 95 F 2.

Drywell temp above 180 F 3.

Drywell pressure above 2.0 psig 4.

Suppression pool water level above +2.0 in 5.

Suppression pool water level below -2.0 in

[5 parameters 9 0.25 ea and 5 values @ 0.25 ea]

REFERENCE Quad Cities QGA-200-1 Rev 1 pg 1 ANSWER 7.03 (2.00) 1.

The recirculation pump flows [0.34] differ by more than 10 percent

[0.33] from established speed-flow characteristics [0.33].

2.

The indicated total core flow [0.34] is more than 10 percent greater than [0.33] the core flow value derived from established power-core flow relationships (0.33].

(***** CATEGORY 7 CONTINUED ON NEXT PAGE *****)

-,w,_

7.

PROCEDUMA - NORMAL. ABNORMAL. EMERGENCY Paco 24 AND RADIOLOGICAL CONTROL REFERENCE 1

l Quad Cities QOA-202-1 Jet Pump Failure Rev 2 pg 1 ANSWER 7.04 (2.50) 1.

Trip EGC return recire flow control to Manual [0.25]

2.

Reduce recirculation flow [0.25] by at least 20% upeed [0.25],

3.

Insert control rods [0.25] starting at the present location in sequence and work backwards [0.25].

Any rod inserted should be continuously inserted all the way to position OO [0.25] (even if the sequence calls for stopping at an intermediate position.)

(After each group of rods check the flow control line and) continue this process until the reactor is under the 100 % FCL

[0.25]

Fo.c]

4.

If a LSSS has not been exceeded',4 verify that reactor power is within operating limits of exsisting recirculation system flow If reactor power continues to increase,/ Scram the reactor [0.25].

- O.

Natify th. Chi!L-Entin;;r [Sr25]c p.u]

-C.

  • etify Radiatie= hotaction to have4 hem. sample-reactor-coolant f:- fi;;ica, red;;t ouil.ity [0.25].

REFERENCE Quad Cities QOA 400-1 Reactivity Addition Rev 3 pg 1 & 2 e

  • f

.\\v e1 ANSWER 7.05 (2.00) 2'/

1.

(QTP 1600-S2,) Control Rod Sequence Review Sheetahas been reviewed and approved.

2.

The RWM has been loaded and verified (by checking for the sign-off on QTP 1600-S2, Control Rod Sequence Review sheet.)

3.

(QTP 1600-S3,) Control Rod Sequence Sheet has been signed and dated by both a Qualified Nuclear Engineer (QNE) and an on-shift SRO before moving control rods in the group.

4.

Either the Rod Worth Minimizer (RWM) is in NORMAL or, if in BYPASS,

,y that a caution card has been placed on the rod movement control l;

switch (per procedure QOP 207-2.)

5.

Permission is obtained from the Shift Engineer to commence rod motion.

[4 9 0.5 ea]

REFERENCE Quad Cities QGP 4-1, Control Rod Movements and Control Rod Sequences, pg 4

(***** CATEGORY 7 CONTINUED ON NEXT PAGE *****)

~

i I

7.

PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Pr.co 25 AND RADIOLOGICAL CONTROL i

ANSWER 7.06 (2.00) a.

1.

Reactor metal temperature 2.

Vessel level 3.

Water temperature

[3 9 0.25 ea]

(Items a.2. and a.3. maybe reversed.)

b.

1.

Increase shutdown cooling flow 2.

Raise vessel water level 3.

Use head spray 4.

Startup the RWCU system 5.

Startup both CRD pumps G.

Bleed through cleanup system and feed through feedwater system.

7.

Flood the main steam lines, and drain through the main steam line drains if the cleanup'sytem is not available.

[5 9 0.25 ea]

REFERENCE QC QOP 1000-5 pg 2 ANSWER 7.07 (2.00) 1.

Reduce power with recirculation (flow to reduce the transient.)

2.

Transfer auxiliary power to T12 (T22).

3.

Start the turbine main shaft suction pump and the EBOP 4.

Raise Reactor Water level to high level alarm point (~+44")

[4 4 0.5 ea]

REFERENCE Quad Cities QGP 2-3 Reactor Scram, Rev 23, pg 1 t

(***** END OF CATEGORY 7 *****)

-p.---,.,e--

-ey-


..-.-,,,,-e..,

.s.---.-.

-,-+-,, - -.ce,

8.

ADMINISTRATIVE PROCEDURES. CONDITIONS.

Paca 26 AND LIMITATIONS ANSWER 8.01 (1.00) 1.

Insert statement at point of termination as to reason for termination.

2.

Insert title of subsequent procedures at point of termination 3.

Insert NA in all remaining blanks 4.

Date, time, and sign the last page 5.

Retain the terminated procedure in the startup package.

[4 0 0.25 ea]

REFERENCE Quad City QGP 1-1 Sec C.8 pg 3 ANSWER 8.02 (1.50) 4 a.

1.

High Neutron Flux Scram o* A?) I"

C# ' "

2.

Safety valve actuation

[2 9 0.5 ea]

b.

High Pressure scran. [0.5] g, a,.' j, h,;,

.,,. /j/

s.,1 p, e

/

f.j o.

REFERENCE Quad Cities Technical Specification 1.2/2.2 Reactor Coolant System pg 1.2/2.2-1 and 2.2 Limiting Safety System Setting Bases pg 1.2/2.2-3 ANSWER 8.03 (2.00) 1.

During any transient which may lead to failure of fuel rods.

2.

A radioactive release which has the potential of exceeding the Technical Specification limits.

3.

A failure of the reactor primary coolant system.

4.

A failure of the containment barriers.

5.

The Loss of the function of a safety system.

[4 0 0.5 ea]

REFERENCE Quad Cities QAP 300-1, Operations Department Organization, Rev 13 C.3.c pg 2 f.D Any GSEP condition: reference QAP 300-2 page 11 2.'

Flooding: reference 00A 010-4 page 2

~

3.

Fire: reference QEP 340-5 page 3 4.'

Scram: reference QAP 300-1 page 5 5.

11 hen relleving the SCRE during normal plant operation:

reference QAP 300-1 page 6.

(***** CATEGORY 8 CONTINUED ON NEXT PAGE *****)

e

-.,v-

--w---,--,,,w-,.---,-.--,,e--,

-,----------w,-,-----,-e-

-m,. - -

-*w

,,m-,w-,w

--w--

~ --,

-.--t----e---emm*y

'- - - - " - + - - -

i b

8.

ADMINISTRATIVE PROCEDURES. CONDITIONS.

Page 27 j

AND LIMITATIONS i

ANSWER 8.04 (2.00) 1.

One, Shift Engineer, SRO 2.

Two, Shift Foreman, SRO 3.

Three, Nuclear Station Operators, RO 4.

One, Equipment Operator, None 5.

Five, Equipment Attendents, None 6.

One, Station Control Room Engineer (SCRE), SRO

[18 @ 0.11 ea]

REFERENCE Quad Cities QAP 300-3, Shift Manning C.3 Rev 8 pg 2 and QAP 300-1 Op Dept Org Rev 13 pg 2, 7, 9,

13, 16, & 17 ANSWER 8.05 (1.50) a.

Any individual who exceeds his approved exposure level is required to promptly report his exposure to radiation protection and his own supervisor.

[0.5]

b.

1.

3 rem /qtr not to exceed 5 (N-18) 2.

7 1/2 rem /qtr 3.

18 3/4 rem /qtr

[3 9 0.25 ea]

c.

False

[0.25]

REFERENCE LIL:

RAD PRO Lesson Plan Quad Cities QAP 1120-2 pg 54 i

ANSWER 8.06 (1

C,j --- 4.[

.h 4 444 ^ '.3 9 REFERENCE FERMI - 10 CFR 55.31.e Quad Cities 10 CFR 55.31.e l

l l

(*****

CATEGORY 8 CONTINUED ON NEXT PAGE *****)

l l

l

8.

ADMINISTRATIVE PROCEDURES. CONDITIONS.

Pega 28 AND LIMITATIONS ANSWER 8.07 (1.50) l a.

1.

Its corresponding normal or emergency power source is Operable.

[0.5]

2.

All of its redundant systems, subsystems, trains, components, and devices in the other division are operable, [0.5] or likewise satisfy the requirements of this specification.

b.

Specification 3.0.B is not applicable in refueling [0.25] or cold shutdown.

[0.25]

REFERENCE Quad Cities Technical Specifications 3.0/4.0 General LCO B. pg 3.0/4.0-2 ANSWER 8.08 (2.50) a.

Pump speed [0.25] shall be maintained within 10% [0.25] of each other when power level [0.25] is greater than 80% [0.25] and within 15% [0.25] of each other when power level is less than 80%

[0.25].

b.

One recirculation pump shall be tripped. [0.5]

c.

To prevent the possibility of LPCI Loop Selection logic selecting the wrong loop for injection [0.5].

REFERENCE Quad Cities Technical Specifications 3.6/4.6 Primary System Boundary, 3.H.1 & 3.H.2 pg 3.6/4.6-5 & Basis 3.6.H. pg 3.6/4.6-13 ANSWER 8.09 (1.00) 1.

When the rod is fully withdrawn the first time subsequent to each refueling.

[0.5]

2.

After maintenance.

[0.5]

REFERENCE i

BSEP:

TS 3.1.3.6 Quad Cities Technical Specifications 3.3/4,3 Reactivity Control pg 3.3/4.3-2 l

(***** CATEGORY 8 CONTINUED ON NEXT PAGE *****)

l l

0 i

,._,m.,

_m,

_ _., _ - ~ _ _ _, _.. - _ _,.. -. -, _ _ _,.. -. -...,.,,,,.,

s 8,

ADMINISTRATIVE PROCEDURES. CONDITIONS.

P cs 29 AND LIMITATIONS ANSWER 8.10 (2.00) a.

At the controls is when the operator is physically within the operating area in front of the Unit panels.

(Defined in QAP-300-T8) [0.5]

b.

1.

Injury to the public or Company personnel 2.

Release off-site above T.S. limits 3.

Damage to equipment, if such damage is tied to a possible adverse effect on public health and safety.

[3 9 0.25 ea) c.

1.

A licensed operator has specifically been assigned the responsibility of monitoring the controls of the unit and responding to all unit alarms.

2.

This same licensed operator remains within line of sight of the unit's front panel.

3.

The licensed Operator, on a periodic basis, ~ 5 to 10 minutes reviews the status of that unit from within the area designed as being close proximity of the main control panels of the unit. [3 @0.25 ea]

REFERENCE Quad Cities Conduct of Shift Operations QAP 300-2 Rev 16 pg 13 & 14, QAP 300-T8 I

(***** END OF CATEGORY 8

          • )

(********** END OF EXAMINATION **********)

' ge

...R O3PY

~

v U. S. NUCLEAR REGULATORY COMMI REACTOR OPERATOR REQUALIFICATION EXAMINATION FACILITY:

QUAD CITIES 1&2 REACTOR TYPE:

BWR-GE3 DATE ADMINSTERED:

86/10/14 EXAMINER:

BISHOP. M.

CANDIDATE INSTRUCTIONS TO CANDIDATE:

Read the attached instruction page carefully.

This examination replaces the current cycle facility administered requalification examination.

Retraining requirements for failure of this examination are the same as for failure of a requalification examination prepared and administered by your training staff.

Points for each question are indicated in parentheses after the question.

The passing grade requires at least 70%

in each category and a final grade of at least 80%.

Examination papers will be picked up four (4) hours after the examination starts.

% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY (q

14.50 24.97 1.

PRINCIPLES OF NUCLEAR POWER PLANT OPERATION, THERMODYNAMICS, HEAT TRANSFER AND FLUID FLOW tt. ; ;

24.;7 t5-ee e5--ei 2.

PLANT DESIGN INCLUDING SAFETY i

AND EMERGENCY SYSTEMS a2 15.00 25.91 3.

INSTRUMENTS AND CONTROLS i

41 l

15.00 25.21 4.

PROCEDURES - NORMAL, ABNORMAL, l

EMERGENCY AND RADIOLOGICAL l

CONTROL l

59.5hb Totals All work done on this examination is my own.

I have neither given nor received aid.

l Candidate's Signature l

l i

l l

~

NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:

1.

Cheating on the examination means an automatic denial of your application and could result in more severe penalties.

2.

Restroom trips are to be limited and only one candidate at a time may leave.

You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.

3.

Use black ink or dark pencil only to facilitate legible reproductions.

4.

Print your name in the blank provided on the cover sheet of the examination.

5.

Fill in the date on the cover sheet of the examination (if necessary).

6.

Use only the paper provided for answers.

7.

Print your name in the upper right-hand corner of the first page of each section of the answer sheet.

8.

Consecutively number each answer sheet, write "End of Category __" as appropriate, start each category on a new page, write only on one side of the paper, and write "Last Page" on the last answer sheet.

9.

Number each answer as to category and number, for example, 1.4, 6.3.

10. Skip at least three lines between each answer.
11. Separate answer sheets from pad and place finished answer sheets face down on your desk or table.
12. Use abbreviations only if they are commonly used in facility literature.

l

13. The point value for each question is indicated in parentheses after the question and can be used as a guide for the depth of answer required.

i

(

14. Show all calculations, methods, or assumptions used to obtain an answer l

to mathematical problems whether indicated in the question or not,

15. Partial credit may be given.

Therefore, ANSWER ALL PARTS OF THE i

l QUESTION AND DO NOT LEAVE ANY ANSWER BLANK.

16. If parts of the examination are not clear as to intent, ask questions of the examiner only.
17. You must sign the statement on the cover sheet that indicates that the work is your own and you have not received or been given assistance in completing the examination.

This must be done after the examination has been completed.

l i

I

18. When you complete your examination, you shall:

a.

Assemble your examination as follows:

(1)

Exam questions on top.

(2)

Exam aids - figures, tables, etc.

(3)

Answer pages including figures which are part of the answer.

b.

Turn in your copy of the examination and all pages used to answer the examination questions.

c.

Turn in all scrap paper and the balance of the paper that you did not use for answering the questions.

d.

Leave the examination area, as defined by the examiner.

If after leaving, you are found in this area while the examination is still in progress, your license may be denied or revoked.

s I

1.

PRINCIPLES OF NUCLEAR POWER PLANT OPERATION.

Pega 4

THERMODYNAMICS, HEAT TRANSFER AND FLUID FLOW QUESTION 1.01 (1.00)

A middle of life reactor startup is in progress.

The reactor engineer has estimated that the reactor should go critical at notch 26 on a particular control rod if the reactor operator reaches that notch at 0800.

HOW WOULD EACH OF THE FOLLOWING conditions or events AFFECT the ACTUAL CRITICAL RCD POSITION (more rod withdrawal, less rod withdrawal, or no significant effect)?

Assume that if no conditions changed, the reactor would have been critical at notch 26 of the indicated rod.

a.

The reactor has been shutdown from extended full power operation for 35 hours4.050926e-4 days <br />0.00972 hours <br />5.787037e-5 weeks <br />1.33175e-5 months <br /> and due to circumstances beyond your control you will not have the indicated rod at notch 26 until approximately 0900.

(0.5) b.

Shutdown cooling is terminated.

(0.5)

QUESTION 1.02 (1.00) i

[TRUE OR FALSE]

a. MAPRAT maintained within limits ensures that transition boiling will not occur in 99 percent of the fuel bundles l
b. Maintaining MAPRAT limits ensures that the APLHGR limits are not violated.

1 l'

l l

(***** CATEGORY 1 CONTINUED ON NEXT PAGE *****)

l

1.

' PRINCIPLES OF NUCLEAR POWER PLANT OPERATION.

Pcca 5

)

THERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW QUESTION 1.03 (3.00)

Explain HOW and WHY Rod Worth changes for the following conditions.

a.

Rod Worth of a center rod compared to a peripheral rod.

b.

Rod Worth when plant conditions change from cold to hot at 1 percent power.

c.

Rod Worth when plant conditions change from hot at 1 percent power to hot at 100 percent power.

QUESTION 1.04 (3.00)

Describe HOW and WHY a centrifugal pumps discharge head is affected for each of the following. (Consider each condition seperatly and assume NPSH is maintained in all cases.)

a.

Suction pressure increases,

b. The discharge valve is throttled closed.
c. The temperature of the fluid being pumped increases.

QUESTION 1.05 (2.00)

The reactor is exactly critical LOW in the intermediate range.

A control rod is withdrawn one notch.

A. Describe WHAT happens to indicated neutron level AND WHY7 I

(Continue your discussion until a steady state condition is reached.

Assume no futher operator action other than ranging the IRH meters.

(No other parameters are changed.)

B. Describe HOW reactor period would respond AND WHY?

i

(***** CATEGORY 1 CONTINUED ON NEXT PAGE *****)

1.

'PRINCIPrER OF NUCrEAR POWER PLANT OPERATION.

Paco 6

THERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW QUESTION 1.06 (1.50)

What are THREE of the design or operational factors that insure adequate Net Positive Suction Head (NPSB) for the recirculation pumps?

QUESTION 1.07 (1.50)

MATCH the appropriate THERMAL LIMIT (a-c), to each FAILURE MECHANISM AND to each LIMITING CONDITION given below:

THERMAL LIMIT

a. Linear Heat Generation Rate (LHGR)
b. Average Planar Linear Heat Generation Rate (APLHGR)
c. Minimum Critical Power Ratio (MCPR)

FAILURE MECHANISM LIMITING CONDITION F1.

Clad melting caused by L1.

Coolant transition decay heat & stored heat boiling following a LOCA F2.

Clad cracking from the surface L2.

Clad plastic strain becoming vapor " blanketed"

< 1%

F3.

Clad cracking caused by L3.

Maximum clad temp-high stress from pellet erature of 2200 des F expansion QUESTION 1.08 (1.50)

The Pellet-Cladding Interaction (PCI) failure mechanism is dependent upon many factors.

List three (3) of these factors.

l

(***** END OF CATEGORY 1 *****)

2.

' PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Peco 7

SYSTEMS QUESTION 2.01 (3.00)

Answer the following in reguard to the Recire System:

a.

In the event both recire pump seals fail, WHAT componment would limit the Reactor Coolant System flow from the seal assembly?

b.

How many consecutive starts are allowed if the Recire Pump MOTOR is at Ambient temperature and if it is at Rated temperature?

c.

What system supplies cooling to the recire pump motors and seals and what components are cooled.

QUESTION 2.02 (2.00)

For each of the following, state whether a ROD BLOCK, HALF SCRAM, or NO REACTOR PROTECTION SYSTEM ACTION is generated for that condition.

NOTE: If two or more actions are generated, i.e. a rod block and a half scram, state the most severe, i.e.

half scram.

a. APRM

'B' downscale, Mode Switch in Run.

1 b.

12 LPRM inputs to APRM

'C',

Mode Switch in Startup.

c. Flow units

'A' and

'B' Upscale (less than 103 percent flow), Mode Switch in Run.

I

d. Reactor water level +55 inches, Reactor Power 18 percent, Mode Switch in Run.

l l

l l

l

\\

i

(***** CATEGORY 2 CONTINUED ON NEXT PAGE *****)

i L

2.

' PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Pcsa 8

SYSTEMS QUESTION 2.03 (2.00)

For the Rod Block Monitor (RBM), provide answers to the following questions :

a. What is the system designed to prevent?

(0,5)

b. When the Meter Function Switch on the 90X-37 Back Panel Meter Section is in the " Count" position, what are the " units" of the indication on the meter and what can be calculated by utilizing the indicated value?

(1.5)

QUESTION 2.04 (3.00)

Attached is a single line diagram of the RHR System (Figure 1).

List the labeled components shown in the flow path for i

each of the following modes of the RER System:

a.

Fuel Pool Cooling Assist b.

Suppression Chamber Spray c.

Drywell Spray QUESTION 2.05 (2.00)

Why is the Standby Liquid Control System (SLC) designed to require at least ninety (90) minutes to pump the SLC storage tank contents into the RPV7 i

QUESTION 2,06 (2.00)

What are FOUR of the FIVE possible causes for an automatic trip of the Reactor Water Cleanup Pump?

(Setpoints not required for full credit)

(2.0)

(***** CATEGORY 2 CONTINUED ON NEXT PAGE *****)

2.

~ PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Peca 9

SYSTEMS QUESTION 2.07 (1.00)

Fill in the blank.

HPCI is designed to provide emergency core cooling during a (Three words)

(1.0)

(***** END OF CATEGORY 2 *****)

m s

3.

INSTRUMENTS AND CONTROLS Pca 10

~ '

4 i

/~

QUESTION 3.01 (1.00)

The IRH's are withdrawn frod'the core as soon as they are no lodger needed.

Why is it important that this be done?

QUESTION 3.02 (1.50)

With the reactor operating at power, you are instructed by the SRO to place the mode' switch in SHUTDOWN, which re.;ults in a SCRAM, aan ta reset the SCRAM as"soon as possible.

~

a.

When can this SCRAM be roset?

[0.5]

b.

' Why does the circuitry not allow the SCRAM to be reset immediately?

[1.0]

s 1 s

QUESTIO

'3.03 (2.50) a.'WhEtTHREEothersystemsareprovidedsignalsf$cm-SheLPRMsystem?

[1.. b]

s b.

What indicatio_n'.does an operator have of a high LPRM level? [0.5]

c.

What indication does an operator have of a low LPRM level?

[0.5]

=

\\

QUESTION 3.04 (1.50)

~

There are six level switches associated with the scram discharge volume;

,'i List the THREE functions they perform and their setpoints.

i I

QUESTION.

3.05 (3.50)

In regard to the Control klod Drive Hydraulic System (CRDH):

a.

What are the THREE functions performed by water discharged from the CRD pump?

[1.5]

b.

What is the purpose of the stabiliLing valves?

[1.0) i c.

How do the stabilizing valves accomplish their purpose?

[1,3)

(***** CATEGORf' 3-CONTINUED ON NEXT PAGE *****)

i 3.

INSTRUMENTS AND CONTROLS Pcca 11 QUESTION 3.06 (3.00)

The reactor is operating at 40% power with the Feedwater Control System in single element control, and level Channel "A" selected for input.

The reference leg isolation valve to the Channel "A" NR GEMAC develops a significant packing leak and the associated reference leg starts to gradually decrease.

Describe the effects on and of the following, assuming no operator action.

Include any setpoints.

a.

Actual RPV water level b.

Indicated RPV water level on Channel "A" c.

FWLC d.

RPS

-liiEG& &4 Ecc5 s7st-r.

e.

f.

PCIS QUESTION 3.07 (2.00)

The control room emergency zone is protected against some toxic gases by a control room HVAC system automatic isolation.

a.

What gases are monitored by this isolation system.

[1.0) b.

What indication is available to alert the operators that the isolation system has actuated?

[0.5]

c.

How is the control room emergency zone protected against toxic gases not monitored by the automatic isolation system?

[0.5]

i l

(***** END OF CATEGORY 3 *****)

l 1.

i 4.* PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Pesa 12 AND RADIOLOGICAL CONTROL QUESTION 4.01 (2.00)

What are FOUR of the five entry conditions for QGA 200-1, SUPPRESSION POOL TEMPERATURE CONTROL?

QUESTION 4.02 (2.00)

According to QOA 202-1 " Jet Pump Failure", there are two indications or symptoms where simultaneously occurring would indicate a failure of a jet pump.

WHAT are these two indications?

(Be specific, include setpoints if needed.)

QUESTION 4.03 (1.00)

According to QGP 1-1, Normal Unit Startup,1f a procedure is terminated at any time during its execution, several administrative requirments must be met.

List FOUR of these requirements that must be performed.

QUESTION 4.04 (3.50)

If while operating at 95% power, with EGC in operation, an

'A' heater high level alarm and a step increase in APRM readings are received.

WHAT Immediate Action Steps would be taken to control reactivity addition?

(Limit your answer to the immediate action steps required by QOA 400-1 " Reactivity Addition")

(An action step may contain more than one action item.)

(***** CATEGORY 4 CONTINUED ON NEXT PAGE *****)

t 4.* PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Poco 13 AND RADIOLOGICAL CONTROL QUESTION 4.05 (0.50)

[TRUE OR FALSE)

Once an Emergency Operating Procedure has been exited, it need not be re-entered even i.f an entry condition is reached.

QUESTION 4.06 (1.50)

According to Procedure QGP 1-2, Unit Startup to Hot Standby, a coupling check is performed each time a rod reaches position 48.

What are THREE actions you must perform if uncoupling is detected during this check?

QUESTION 4.07 (2.00)

During the performance of QGP 1-2, Unit Startup to Hot Standby, when Reactor Pressure reaches approximately 875 psig rods are notched in to stop the pressure rise and pressure is maintained between 850 psig and 920 psig.

What are the FOUR methods allowed to maintain RPV pressure within the specified band.

QUESTION 4.08 (2.50)

In order to assure control room operators are attentive to their panels at all times, six actions or performances are forbidden by QAP 300-2, Conduct of Shift Operations.

What are FIVE of these actions or performances?

l i

(***** END OF CATEGORY 4 *****)

(********** END OF EXAMINATION **********)

l l

l

6 EQUATION SHEIT f = ma v = s/t i

Cycle efficiency = Net Work (out) -

2 w = ms s = v c + 1<at E***37 (i")

0 2

E = aC a = (v, - y ) / c 2

A = AN A = A,e KE = hev v

=v

+a PE = mgh ra = e/c A = in 2/cq = 0.693/tg W = vaP' (eff) = (t, )(e )

s t

AE = 931t.m (Cg+t) b Q=$ CAT y = I.4X p

, Q = UAAT I = I ux

~ ~ Pur = W ' I I = I, 10 *'

~

g 5UR(th TVL = 1.3/u P=P 10 e /T E7L a 0.693/u t

P=P o

'SUR = 26.06/T T = 1.44 DT SCR = S/(1 - K,gg) fA

\\gf,o)

CR = S/(1 - K,gg )

SUR = 26 1 l

x J

1(

  • ff}1 = CR (1 - K,gg)'2

=

~

T = '(1*/o ) + [(i a)/1,g,o]

2 T = t*/ (o _ g M = 1/(1 - K,gg) = CR /CRO g

~ 8)!

eff M = (1 - K,g,)q/(1. g,gg)g 8"I

-1)I eff " #eff eff

/K j

eff SDM = (1 - K,fg)/K,gg

[1*/TKfgg.] + [I/(1 + A,gg )]

1* = 1 x 10 seconds

~

T p=

P = E4V/(3 x 1010)

A,gg = 0.1 seconds A

E = No Idyy=Id22 UATER PARAMETERS Id =Id g

2 2

1 gal. = 8.345 lba R/hr = (0.5 CE)/d g,,,,,,)

I gal. = 3.78 liters R/hr = 6 CE/d (feet) 3 1 fc - 7.48 gal.

MISCEI.L\\NEOUS CONVERSIONS 10 Density = 62.4 lbm/ft 1 Curie = 3.7 x 10 dps Density = L gm/cm i kg = 2.21 1ha 3

Heat of var ori: scion = 970 reu/lbm 1 hp = 2.54 x 10 BTU /hr 6

Hest of fusica = 144 Bcu/lba 1 Mw = 3.41 x 10 Btu /hr 1 Atm = 14.7 psi = 29.9 in. I'g.

1 Btu = 778 f t-lbf l

1 ft. H O = 0.4333 lbf/in 1' inch = 2.54 cm 2

F = 9/5 C + 32 "C = 5/9 ( F - 32) l

i h

[1 i!

58 E

@x M x

A toop - a

<x

/

\\

(

)

@N X io.p.-

_rv I I e,

U$

\\ol

/~-D c8 X'n

'k' r

m.

c-------_----..

'W_

4 I

IE"

3.,

,.. N.

'48 t 1

i B, - -

i... _ _ _ _ _ ;

esting

-- x.

x fe

fG A.,

l n

X.

X.

7~-

og-n op p,

f, 4

m 4> me 1

)H5 a

'O'*r z

gi) 7

-N-tx:

4

[gy y.~.%' '~

-%, h

'~

W h3

, d-r L....

j a.....

+

RESIDUAL HEAT REMOV AL "9= 2

1.

PRINCIPLES OF NUCLEAR POWER PLANT OPERATION.

Paco 14 IllERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW ASER0:?Y ANSWER 1.01 (1.00) a.

Less rod withdrawal (due to Xenon burnout)

b. More withdrawal (due to heatup)

REFERENCE G. E. Reactor Theory, pgs.

85, 66 Quad Cities Rx Theory Fission Product Poisons. pg 70 figure 60 Coefficients of Reactivity pg 48 ANSWER 1.02 (1.00) a.

FALSE

b. TRUE REFERENCE HTFF, pp 31 Quad Cities Heat Transfer and Fluid Flow pp 9-24a.

(***** CATEGORY 1 CONTINUED ON NEXT PAGE *****)

1.

PRINCIPLER OF NUCLFAR POWER PLANT OPERATION.

Paco 15 THERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW ANSWER 1.03 (3.00) a.

Control rods in the center of the core are exposed to a higher thermal flux than,those at the core periphery and, therefore, have a greater worth, trod worth would be increased anywhere in the core where a radial thermal neutron flux peak existed even if it were an cdge rod.)

b.

As moderator temperature increases, its density decreases resulting in longer thermal diffusion lengths.

This allows thermal neutrons to travel further and be absorbed by the rod; thus, rod worth increases with an increase in moderator temperature.

c.

As voids increase, again less moderations takes place.

Again, thermal neutrons travel further; however, voids tend to depress thermal flux because of the very poor moderation.

Thus, as voids increase, rod wort decreases.

REFERENCE QC Reactor Theory, pages 58 and 60 ANSWER 1.04 (3.00)

a. Head inceases [0.5] the pump is still putting the same amount of work into the fluid, therefore the same delta pressure across the pump, so as the suction pressure increases so will the discharge head [0.5]

5

b. Head increases [0.51 as system resistance to flow increases, pump head increases [0.5]

c.

Head decreases [0.5] as temperature increases, system resistance to flow decreases (lower viscosity) therefore head decreases [0.5].

REFERENCE Monticello, Thermodynamics and fluid flow ch 7 pg ill Quad Cities, HT & FF Fluid Statics, Pump Characteristics, pg 6 6-102 j

/

(***** CATEGORY 1 CONTINUED ON NEXT PAGE *****)

I

1.

FRINCIPLES OF NUCLEAR POWER PLANT OPERATION.

Page 16 THERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW ANSWER 1.05 (2.00)

A. Neutron level would start and continue to increase until the point of adding heat is reached.

As the coolant heats up, negative reactivity is added and power turns.

Power would stablize at the point of adding heat.

B. Period would take a step jump due to the production of prompt neutrons.

Immediately after this step, the rate of power change decreases to a rate controlled by delayed neutrons until the reactivity is no longer being increased.

Then a sharp drop would occur as the rate of reactivity addition drops to zero.

A stable period would continue until negative reactivity is inserted.

Stabilises at infinity.

REFERENCE Dresden NUS Theory Quad Cities Theory Review pages 44-45 and 78.

ANSWER 1.06 (1.50)

1. They are physically located as far below the normal water line as possible to provide the greatest static head.
2. With feed flow less than 20% they are kept on minimum speed.
3. At high power operation adequate NPSH is obtained from feedwater subcooling.
4. Low reactor Vessel water level trip, cavitation interlock.
5. Suction valve closed trip, cavitation interlock.

(Any 3 @ 0.5 ea)

REFERENCE DRESDEN - Recire System Lesson Plan pg 16 & 18 GE Thermodynamics, Heat transfer & Fluid Flow, page 7-93 & 94 Quad Cities LIC 0202-1 pg 19 and 21

(***** CATEGORY 1 CONTINUED ON NEXT PAGE *****)

a 1.

PRINCIPLES OF NUCLEAR POWER PLANT OPERATION.

Paco 17 THERMODYNAMICS. HEAT TRANSFER AND FLUID FLOW ANSWER 1.07 (1.50) a.

F3. L2

b. F1. L3
c. F2. L1 REFERENCE EIH:

GPNT, Vol VII, Chapter 10.2-23 Quad Cities Heat transfer and Fluid Flow pg 9-16a, 9-19a, and 9-34a ANSWER 1.08 (1.50)

Fuel rod power level Fuel rod exposure Rate of power increase Fuel pellet design Previous power history Presence of embrittling agent

^

"b"

'p d*"'""^

f3 required at 0.5 each)

REFERENCE Fuel System Description, pg 15, 16 GE HTFF pg 9-107, 108 Quad Cities Heat Transfer and Fluid Flow pg 9-45a M 9-46a

._/ F-17.

Ga>)

Ws, lt o. r%, i:. : 2.:1 - 2, i rin, r% I, z, 2 0.

(***** END OF CATEGORY 1 *****)

2.

PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Paro 18 SYSTEMS ANSWER 2.01 (3.00) a.

Breakdown bushing

[1,0]

b.

Two at ambient, one at rated.

[0.5 each]

c.

RBCCW Oil Coolers (Will also accept bearings instead of oil coolers)

Seal Coolers

[0.33 each]

REFERENCE Quad Cities, Lesson Plan, LIC-0202-1, PP. 6 and 8 ANSWER 2.02 (2.00)

a. Rod Block
b. Half Scram

/b i{~A' t!). En-Gs 4-.

//. i.;a L

c. Roi "lach4
d. No Reactor Protection System Action REFERENCE Quad Cities RPS and APRM Lesson Plans

(/. 50 )

ANSWER 2.03 (W

a.

Local fuel damage (by generating a rod withdrawal block).

(0.5) b.

Units = volts [0.5], number of operable LPRM inputs can be calculated (by using 1 volt per operable input) [1T&].

0. =

t I

1

(***** CATEGORY 2 CONTINUED ON NEXT PAGE *****)

2.

PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Paco 19 SYSTEMS REFERENCE QC Lesson Plan Rod Block Monitor - LIC-0700-5, pp. 2 of 22.

QC Lesson Plan Rod Block Monitor - LIC-0700-5, pp. 18 of 22, Sec. 2.b.(4).

QC LessonPlan Rod Block Monitors - LIC-0700-5, pp. 21 of 22, Sec III.C.b.

ANSWER 2.04 (3.00) a.

Spool piece, 43 valve, pump HX, 19 valve, spool piece.

(1.0) b.

7 valve, pump, HX or 16 valve, 34 valve, and 37 valve.

(1.0) c.

7 valve, pump, HX or 16 valve, 23 valve and 26 valve.

(1.0)

(HX OR 16 valve acceptable)

REFERENCE QC Lesson Plan, RHR LIC-1000-1, Fig.

8, Fig. 5, and Fig. 4.

ANSWER 2.05 (2.00)

An excessive injection rate could result in poor mixing [0.5] of the coolant and boron [0.5] and result in reactivity or power chugging

[0.5] which in turn could cause fuel damage [0.5].

l REFERENCE i

j QC Lesson Plan - Standby Liquid Control LIC-1100, pp. 11 of 14, Sec.

IV.A.B.C.

(***** CATEGORY 2 CONTINUED ON NEXT PAGE *****)

l

_ _ _. _ - _.. ~.

2.

PLANT DESIGN INCLUDING SAFETY AND EMERGENCY Pcco 20 SYSTEMS ANSWER 2.06 (2.00) a.

Pump Low Flow (30 gpm) b.

High bearing cooling water temperature.(140 deg. F) c.

The TWO valve not full open (OB Inlet Isolation Valve) d.

The FIVE valve not full open (IB Inlet Isolation Valve) e.

EIGHTY valve full closed (Outlet to FW Hdr.)

[any FOUR @ 0.5 each]

( 1. S y2-REFERENCE QC Lesson Plan - Reactor Water Cleanup System - LIC-1200, pp. 10 of 13 Sec. B.4.

ANSWER 2.07 (1.00)

Small Line Break (1.0)

REFERENCE QC Lesson Plan LIC-2300-1, pp. 2

(***** END OF CATEGORY 2 *****)

l 3.

INSTRUMENTS AND CONTROLS Peca 21 1

ANSWER 3.01 (1.00)

To prevent reaching the design lifetime of the detectors prematurly.

REFERENCE Quad Cities, Lesson Plan, LIC-0700-2, IRM's, Pg. 5 ANSWER 3.02 (1.50) a.

After a 10 sec. time delay.

[0.5]

b.

Allows time to ensure all rods have completed their SCRAM stroke.

[1.0]

REFERENCE QC, Leson Plan,LIC-0500-1,RPS, pp 44.

ANSWER 5.03 (2.50) a.

- Rod Block Monitor [0.5]

- Process Computer [0.5]

- AFRMs [0.5]

b.

High - Red light on full core display

[0.5]

c.

Low - Blue light on full core display

[0.5]

REFERENCE Vermont Yankee NPC Systems Manual, Nuclear Instrumentation Quad Cities, Lesson Plan, LIC-700-3, PP. 11, 3

(***** CATEGORY 3 CONTINUED ON NEXT PAGE *****)

3.

INSTRUMENTS AND CONTROLS Paco 22 ANSWER 3.04 (1.50) 1.

SCRAM discharge volume high level ALARM [0.25] 10 gal. [0.25].

2.

Control rod block [0.25] 25 gal. [0.25]

3.

Reactor SCRAM [0.25] 40 gal. [0.25]

REFERENCE Vermont Yankee NPC Systems Manual, Control Rod Drive Hydraulic System Quad Cities, Lesson Plan, LIC-0300-2, Pg. 28 ANSWER 3.05 (3.50) a.

- Drive water

- Charging water

- Cooling water

[3 9 0.5 each]

b.

The purpose is to maintain a relatively constant flow through the pressure control valve so stable drive water pressure is maintained during rod movement.

[1.0]

c.

The stabilizing valves close on a rod movement signal to offset the additional flow through the drive water header.

[1.0]

REFERENCE Vermont Yankee Systems Manual, Control Rod Drive System Quad Cities, Lesson Plan, LIC-0300-2, Figure 5, Pg. 26 ANSWER 3.06 (3.00) a.

Actual vessel level is decreasing.

b.

Level Channel "A" will indicate increasing water les 1.

c.

FWLCS will close the FRVs to try to maintain level.

d.

Reactor will scram 9 +8" due to low reac, tor water level.

PCIS Creer 1 1 eletieny HPCI initiation 79 -59".

f.

PCIS Group 2 and 3 isolations also 6 +8"je l/ :- doy I nJ. /,,,/ - s f."

s re. AN 5'; ~

  • N

f'~ U., h ACS hp

% u:: hoy o !' Z, E M y' S A>> r.

p.f dd sCl% 8.1, A. o~/

(***** CATEGORY 3 CONTINUED ON NEXT PAGE *****)

3..

INSTRUMENTS AND CONTROLS Paco 23 REFERENCE Quad Cities, Reactor Level and Pressure, LIC-0263, PP. 12 q,.'

...,t.

. i..

s:.

1L2,.,

> ; i_,

Teco.,J.

f. '.,, :

~ /. : *,, ? r o.,,.. 9 z.

ANSWER 3.07 (2.00) a.

Ammonia Clorine Sulfur dioxide

[3 0 0.33 each]

b.

Control Room HVAC " Major Trouble" Alarm.

[0.5]

c.

Manual isolation by operator.

[0.5]

REFERENCE Quad Cities, Lesson Plan, LIC 5750, Venti 11ation, PP. 27 t

(***** END OF CATEGORY 3 *****)

r 4.'

PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Paco 24 AND RADIOLOGICAL CONTROL ANSWER 4.01 (2.00) 1.

Suppression pool temperature above 95 F.

2.

Drywell temperature above 180 F.

3.

Drywell pressure above 2.0 psig.

4.

Suppression pool water level above +2.0 in.

5.

Suppression pool water level rb;c; -2.0 in.

[any 4 @ 0.5 each]

REFERENCE Quad Cities, Procedure QGA 200-1, Suppression Pool Temperature Control, PP. 1 ANSWER 4.02 (2.00) 1.

The recirculation pump flows [0.34] differ by more than 10 percent

[0.33] from established speed-flow characteristics [0.33].

2.

The indicated total core flow [0.34] is more than 10 percent greater than [0.33] the core flow value derived from established power-core flow relationships [0.33].

REFERENC3 Quad Cities QOA-202-1 Jet Pump Failure Rev 2 pg 1 ANSWER 4.03 (1.00) 1.

Insert statement at point of termination as to reason for termination.

2.

Insert title of subsequent procedures at point of termination 3.

Insert NA in all remaining blanks

4. Date, time, and sign the last page S. Retain the terminated procedure in the startup package.

(Any 4 @ 0.25 ea)

(***** CATEGORY 4 CONTINUED ON NEXT FAGU *tttt)

b 4..

PROCEDURES - NORMAL. ABNORMAL. EMERGENCY Pega 25 AND RADIOLOGICAL CONTROL REFERENCE Quad dity QGP 1-1 Sec C.8 pg 3 ANSWER 4.04 (3.50) 1.

Trip EGC [0.25] return recirc flow control to Manual [0.25]

2.

Reduce recirculation flow [0.25] by at least 20% speed [0.25],

3.

Insert control rods [0.25] starting at the present location in sequence and work backwards [0.25].

Any rod inserted should be continuously inserted all the way to position 00 [0.25] l'even if the sequence calls for stopping at an intermediate position.fEsd.7 After each group of rods check the flow control line [0.25] and continue this process until the reactor is under the 100 % FCL

[0.25]

D ::]

4.

If a LSSS has not been exceeded,averify that reactor power is within operating limits of exsisting recirculation system flow

[0.25].

If reactor power continues to increase,/ Scram the reactor

[0.25].

Dn]

u tify th. Clift Ex:ireer [e.asy:-

n e

S.

NvLTfMedistien Tretection-to-have +k

-aample reactor-coolant.+{~

-LA-25] fvr Iissivu n vdset-metivity-[&.261.4.,

REFERENCE Quad Cities QOA 400-1 Reactivity Addition Rev 3 pg 1 & 2 ANSWER 4.05 (0.50)

False REFERENCE Quad City QGA Caution #1 and Statement immediatly after each see of entry conditions pg 1 plus (ttttt CATEGORY 4 CONTINUED ON NEXT PAGE *****)

F 4.

PROCEDUFM - NORMAL. ABNORMAL. EMERGENCY Pcco 26 AND RADIOLOGICAL CONTROL 4

T;. 4 JL d' ' * ' IS' fl'

  • ANSWER 4.06 (1.50) y pos;/,..

1.

Stop rod withdrawals.

' S. 4/o i. I A In M * ' '

f 2.

Notify the shift engineer.

. /t,.;, s 3 3.

Refer to the abnormal procedures y REFERENCE d'/ 35 0#"

Quad Cities, Procedure QGP 1-2, Unit Startup to Hot Standby, PP. 16 ANSWER 4.07 (2.00) 1.

Operate RCIC 2.

RWCU system reject flow 3.

Vary power with CR's 4.

SRV manual operation to prevent reaching 1960 psig if the other three methods fail to maintain pressure.

REFERENCE Quad Cities, Procedure, QGP 1-2, Unit Startup to Hot Standby, PP. 6 ANSWER 4.08 (2.50) 1.

Sleeping.

i 2.

Habitual or chronic lack of attentiveness.

3.

Card playing, games, or other distractions from prescribed duties, c

4 7 Alcohol or drug use.

5.

Practical jokes which could reduce the ability of persons or equipment

(

to perform as required.

6.

Other acts which could adversely affect the ability of individuals or N

equipment to perform their intended safety functions.

N

[Any 5 9 0.5 each]

b "' I "

REFERENCE kl.Hul cl'" "4n Jin

,,.p's "A " Ik :'t

'Y'"'ll ', / " c. +1* -'*

  • l "* 0"'*/

"'fr~ s l' -7)

" l'I" '"1 m tA-rose d rL da.J da Quad Cities, Procedure QAP 300-2, Conduct of Shift Operations, PP. 6

(***** END OF CATEGORY 4 *****)

(********** END OF EXAMINATION **********)

1

. _ - - _