ML20213E811

From kanterella
Jump to navigation Jump to search
Requests Reallocation of Technical Assistance Funds & Approval of New Projects.Project Identification Summaries & Contract Mods Encl.Prompt Action Requested So Contract Actions Can Be Initiated Prior to 840601
ML20213E811
Person / Time
Issue date: 05/16/1984
From: Mattson R
Office of Nuclear Reactor Regulation
To: Funches J
Office of Nuclear Reactor Regulation
Shared Package
ML20213E815 List:
References
CON-FIN-A-1301, CON-FIN-A-2317, CON-FIN-A-3708, CON-FIN-A-3711, CON-FIN-A-3719, CON-FIN-A-3750, CON-FIN-A-3772, CON-FIN-A-6457, CON-FIN-A-6496, CON-FIN-A-6801, CON-FIN-A-7281, CON-FIN-B-2534, CON-FIN-B-2537, CON-FIN-B-2538, CON-FIN-B-2543, CON-FIN-B-2951, CON-FIN-B-2961, CON-FIN-B-8625, CON-FIN-B-8634, CON-FIN-B-8665, CON-FIN-B-8681, CON-FIN-B-8682, CON-FIN-B-8696, CON-FIN-N-3008, CON-FIN-N-3031, FOIA-87-6 NUDOCS 8405260445
Download: ML20213E811 (5)


Text

'

l gggy3 gyavs:2 E

NUCLEAR REGULATORYEOMMISSION h

E WASHINGTON. D. C. 20555

'+,..'...#'

NAY 14M MEMORANDUM FDR: Jesse N. Funches Director Progratr. and Planning Analysis Staff, NRR FRDM:

Roger J. Mattson, Director Division of Systems Jntegration

SUBJECT:

REQUEST FOR REALLOCATIDN DF7ECHNICAL ASSISTANCE FUNDS AND APPROVAL DF NEW-fROJECTS DSI conducted a inid-year resources review on April 30. 1984. As a result I have identified a few high-priority new projects for which I would like to initiate work in FY 1984. Project Identification Sumaries (PIDS) are attached. These proje::ts are:

1.

Evaluation of Licensee Confonnance to Beneric Letter 83-28 (Salem ATWS) (Two FINS) 2.

Review of J.icensee Submittals on BWR Primary System Pipe Cracks 3.

Review of the PRA for Seabrook n

=

4.

User's Guide for-PARTS Lomputcr ringram 5.

Clima+ ology of Extreme Winds in Scuthern California.x 6.

Tornado Climatology

)

I have also agreed to several inodifications to existing contracts as noted on the attached list. However'caupled with the increased new work, I am proposing to delay funding commitments on other projects where there have been contract delays or other problems which would cause excess carryover.

l As a result of these changes, DSI can return to the NRR Reserve Fund 561,000.

I would appreciate your prompt action on this request so that the contract actions can be initiated prior to June 1.

)

Roger. Mattson, Dire tor

..D1vLsion Df Systensintegration cc:

L. Solander D. Heyer C. Velez R. Swisher T. DiGalorra Kk 9

n5 m

Y FY84Repbhamming/ Redirection t,,

dperatina Reactors l FIN AM00NT TITLE REMARKS (S K) y B2951

-0*.

Utilization bf COBREE Computer Code

$10K additional required to 1

\\

complete two submittals in accordance with proposal; add two additional sub-

_s cittals for which reviews requested by EQB NEW

+55 Evaluation of License Conformance Ihitiate work on three to Generic Letter 83-28 (Salem ATWS)

MPA's; timing of work of work not known at time NRR FY 84 Operating Plan established NEW

+40 0

Review of Licensee Submittals on Initiate work on MPA; timin (B2538)e

~4 BWR Primary System Pips Cracks of work not known at time NRR FY 84 Operating Plan established s

B2534

+5.

'B&W Lynxt Computer Review Original budget under-estimated; additional funds g

required for proposal NEB

,+60 Review of Process Control Programs Late contract start require

't less FY 84 funds;ignated in note that $85K was' des Reserve Fund for this project BB695./

-2 Rad Consequences: Evaluation Funds were excess after SGTR Accidents proposal negotiated N3008 /

-6*

Tornado Missile PRAs for ors OR submittal not received as anticipated A6801 '

-100 Review Test Procedures for Contract fu..ded through DL Charcoal Adsorbers (Note: $25K previously redirectedtoB2325)

B8681

-65 Atmospheric Diffusion Modelling Delayed contract start; als !

for ERFs IE delay in scheduling OR appraisals (only three scheduled this FY)

B2961

+18 Climatology of Extreme Winds ir.

Provide basis for staff (NEW)

Southern. California assessments on operating plants such as San Onofre 1.

i Summary Funds Needed:

$178 Funds Available: $173K F9nds Needed from Reserve

$ SK x

ONote:

$19V,previouslyreRre{.edfromN3008toB2951

\\

i L3I Request for Mid-Year FY 84 Reprogramming / Redirection

, Casework FIN AMOUNT TITLE REMARKS N3631

+30 Tornado Missile PRAs for OL Additional submittal Applicants received (Seabrook); review must be complete 9/84 B2543

+10 Utilization of COBREE Computer EpBadvises4-5 additional Code submittals anticipated this year; budget sufficier for 4, of which 2 already performed NEW

+15 Evaluation of Applicant Conformance See comments under Operatir to Generic Letter 83-28 (Salem ATWS)

Reactors A6496

+40 Radwaste Volume Reduction and To initiate work on two Solidification Topical Reports additional topicals not previously anticipated (Note: Increase in topicals is due to limitations on LLW at burial grounds) j 12537

+10 Meteorological Data Tape and Computer Add additional task to Code Support modify code to enable staff to run on Data General MV8000 B8682

- 5 v' Atmospheric Diffusion Modelling Delay in contract; work to for ERFs-be scheduled for FY 85 A2317

-50 d Radiological Assessment for NRC EIS Contractor loss of staff; stop work order issued.

Work to be perfomed with PSY.

A3719

-30 '

Generic Containment Analyses Another project (FIN A3747) has excess carryover, will transfer $30K funds to A3719, thus this budget not required A3772

-25 Review of PRA for Shoreham Funds were available by transferring from A3705 above (Note: Total estimate cost of A37.72 is $80K)

NEW

+50 Review of PRA for Seabrook Work not previously anticip ed for FY 84 when Operating Plan / Fin Plan approved

\\

l

.2 l

Casework (Con't)

FIN AMOUNT TITLE REMARKS A1301

' 25 Review of Grand Gulf Hydrogen Not likely that applicant Igniter submittal will be available before late FY; sufficient funds already obligated A6457

-60 Control of Heavy Loads Submittals delayed; contrac will extend to FY 85; sufficient carryover with already obligated funds A3711 Safety Evaluation Core-Melt for Contract to be modified to GESSAR/ Limerick enable BNL to QA GESSAR run by using Battelle Columbus

~

(RES) Codes; $65,000 estimated funds required, however, will be funded by transferring from A3705 already obligated. (A3705) is Westinghouse SP/90 which is delayed).

Suranary Funds Needed:

$155 Funds Available 195

.' Return to Reserve 40K Fund:

i

..y o n.....

FY 84 Reprogramming /Redir:ction

'[

Sa_fety Technology EIN AMOUNT TITLE REMARKS B8625

+50 LWR Severe Accident Consequences Contractor is ahead of for LWRs schedule and performing work not previously anticipated until FY 85 B8634

+10 Severe Accident Core / Vessel /Contain-To modify contract to ment Interactions support DST.

(See T. Speis

+tS % )

FIN N4012 memo dated 4/16/84 to

?

R.,Mattson)

A3750

+20 Mitigation Features for Risk Restore funding previously Analyses for Mark II BWRs redirected to A7272 A7281

-20 /

Steam Generator Tube Rupture Late contract start due to Study delay in FIN Plan approval A3708

-75' Evaluation of Occupatio'nal Dose Work planned for this year Reduction Actions cannot begin until 8/84 since pace of current work is slow due to difficulties in scheduling plant visits B8665

-91 e Documentation & Maintenance of AEB Agreement with TIDC to Codes have work performed by their contractor.

NEW

-50 Containment Performance Guidelines Delay in approval of TAP has caused late start of effort; current estimate of 7/1/84 to initiate contract NEW

+40 User's Gu'ide for PARTS Computer One of a series of codes Program (LATAP) that are available publicly; such a guide will be of benefit to staf; in evaluating licensing actions A3767

+75 Evaluating Methods for Reducing DSI recomends authorizing Vulnerability to Sabotoage (A-29)

PNL proposal (for which i

funds are available) but believes BNL proposal for a portion of effort has merit as well.

B2960

+15 Tornado Climatology Update R.G. 1.76 and WASH-1300 to incorporate i

new and additional in-formation on tornado occurrences and tornado characteristics.

1 Sumary Funds Needed:

$210K Funds Available:

236K Return to Reserve 26K