g 0 0 ti,<,
UNITED STATES h]d-ATOMIC ENERGY COMMISSION E,NY
- wasmsoros. o c. nsas
,g/
%n e
~ NOV 0 61972 l
Joseph M. Hendrie Deputy Director for Technical Review Directorate of Licensing TEC;iNICAL ASSISTANCE REQUEST NO. ORB-2-45 Plant Name: Quad Cities Units 1 and 2 Docket Nos.:
50-254 C 50-265 Licensing Stage:
Operating License (90% power) i Requesting Branch:
Operating Reactors Branch #2 Project Leader:
John I. Riesland Requested Completion Date:
November 27, 1972 3 ranches Involved: Mechanical Engineering Structural Engineering Quality Assurance Description of Request:
Your review and co::ments on the attached report regarding the Quad Citiet Unit 2 Torus Ring deader Kanger failure is requested.
/.
,,,f/ "
/k.!,, i. N'O
^
/ onald J f ovnolt D
I Assistant Director for Operating Reactors Directorate of Licensing
Enclosure:
Ceco's ler dtd l_0/27/_72 w/ Quad Cities Special Report #5 cc w/ enclosure:
D. Lange R. Maccary R. Vollmer cc w/o enclosure: