ML20206F433
| ML20206F433 | |
| Person / Time | |
|---|---|
| Site: | 07109079 |
| Issue date: | 06/11/1986 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Rowe B WESTINGHOUSE HITTMAN NUCLEAR, INC. |
| References | |
| NUDOCS 8606240466 | |
| Download: ML20206F433 (2) | |
Text
.
}I-907f Distribution:
NET $ll]
Docket File H
3 Region I MG SS RH0degaarden (2)
NMSS R/F FCTC:Rl!0 JUN11IN6 FCTC R/F 71-9079 Approval Record File Westinghouse Hittnan Nuclear Incorporated ATT!!: Mr. Bruce S. Rowe 9151 Rtasey Road Colunbia,PtD 21045 Gentlenen:
As requested by t!cstinghouse Hittman Nuclear Incorporated application dated April 14, 1986, and pursuant to 10 CFR Part 71, Certificate of Compliance No. 9079 for the Model No. HN-100 Series 2 package, is amended to authorize the additional contents contained in liner l'os.19 and 23 in accordance with Westinghouse liittman Nuclear Incorporated letter dated April 14, 1986. All other conditions of Certificate of Compliance
!!o. 9079 shall recain the same.
This authorization shall expire August 31, 1986.
FOR THE U.S. !!UCLEAR REGULATORY C0tf4ISSIO'l Ori in,' "i ned by fi k.facD5daTDthief 5
Charle Transportation Certification Branch a
Division of Fuel Cycle and Material Safety, WSS
Enclosure:
Approval Pecord cc v/ enc 1:
l'r. Wendell Carriker Departrent of Transportation GPU !!uclear Corporation ATTN: Mr. Ray E. Hahn P.O. Box 480 Middletown, PA 17057 3
~~
ome >I FCTC Fg 8606240466 860611
!.u.=405gaaE5n:alml:Plac[Nali R
ADOCK 0710 9
C 06th /,86 06/ j./86 t
( une ronu ne no-so> Nacu ono OFFICIAL RECORD COPY
O' Transportation Certification Branch Approval Record flodel tio. W!-100 Series 2 Package Docket !!o. 71-9079 By application dated April 14, 1986, Westinghouse Hittnan Nuclear Incorporated requested a change to the authorized contents of Certificate of Conpliance
!!o. 9079 to allow additional contents-in the packaging for two, one-time shiprents.
During the solidification canpaign and in preparation of the radioactive shipnent records, it was discovered that liner !!os.19 and 23 (H!i-100 sized liners) had been solidified containing greater than LSA concentrations of Sr-90 and exceeds the cunulative LSA concentration Ifnits for nixtures of radionuclides. The quantity of Sr-90 in both liners is greater than A2. Specific details on each liner are listed below.
Liner
- 19
- 23 Specific Activity of Sr-90 (nilli ci/gn) in liner 0.013 0.019 LSA limit (nilli cf /gn fron 10 CFR Part 71.4 0.005 0.005 Since the solidified waste package is greater than LSA concentrations and greater than an A2 quantity, a Type B package would be required. A Type 8 package for these liners does not exist.
Both Westinghouse Hittnan Huclear Incorporated and GPtf !!ucicar Corporation are expected to take steps to preclude radioactive naterial levels in excess of current 10 CFR Part 71 limits.
In view of the alternative to repackage the solidified waste and the linited dispersibility of the waste as solidified, the two shipnents are exec.pted from Type B packaging of 10 CFR Part 71 in accordance with the stattents and conditions of 1.'estinghouse !!ittnan ?!uclear Incorporated letter dated April 14, 1986.
It is concluded that the exenption for these linited shipnents will not endanger life or property.
Ofirical "taned by CHAE.S E.1.%CD04AJ4)
Charles E. tiacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and flaterial Safety, MISS Date: yi; 7 OF F ICE )
F"" >
DATE) enc ronu ats cio nai sncu o24o OFFICIAL RECORD COPY l