ML20198D450

From kanterella
Jump to navigation Jump to search
Partially Withheld Assessment of Allegation AQ-88 to Allegation Category Qa/Qc 5A, Repair,Rework & Maint Re safety-related Work Performed W/O Paperwork by Illegal Aliens
ML20198D450
Person / Time
Site: Comanche Peak  
Issue date: 06/07/1985
From: Livermore H, Watson V
NRC, NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To:
Shared Package
ML20198C597 List: ... further results
References
FOIA-85-59, FOIA-85-89 NUDOCS 8605230278
Download: ML20198D450 (2)


Text

-_

1.

Allegation Category: QA/QC 5A, Repair, Rework, and Maintenance 2.

Allegation Number: AQ-88 3.

' Characterization:

It is alleged that safety-related work was performed, without paperwork, by illegal aliens.

4.

Assessment of Safety Significance:

The NRC Technical Review Team (TRT) attempted to identify work packages, drawings, or system identifications that supported this allegation, but could'not locate such documents. The TRT interviewed six ASME mechanical inspectors and learned that the persons alleged to be " illegal aliens" were employed as helpers who performed cleaning or preparation tasks, but no actual safety-related work.

The TRT was unable to find any instances where work was performed without paper-work.

Persons employed as helpers were supervised by personnel who were fluent in English as well as in the language necessary to provide oral instructions.

5.

Conclusion and Staff Positions:

Based on documentation and on interviews with mechanical inspectors, the TRT concludes that this allegation cannot be substantiated.

The alleger was not identified; therefore, no exit interview was conducted.

(

7.

Attachments: None.

Reference Documents:

1.

GAP witness I.

2.

TUGC0 security questionnaire.

3.

TUGC0 NOT-1043, Form A, Rev. O, " Experience and Qualification."

8.

This statement prepared by:

kph Y,d b C[6hf V. Watson, TRT Date Technical Reviewer Reviewed'by:

&m&d d W

'H.

Livermore, Date Group Leader Approved by:

V. Noonan, Date Project Director S[b5230278 8 b512 PDR FOIA ^

~

L QARDEBS-99_._

_PDR 0-145

. _. ' ~

i

This page intentionally left blank

[

l l

0-146 l