1 ' %
pulc o A
g Ag UNITED STATES NUCLEAR REGULATORY COMMISSION
- WASW M. TON, D. C. 20555
%....+);e ,
SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING AMENDMENT NO. 12 TO FACILITY LICENSE NO. ,R-53 x Ul[l]ERSITYOFORLAHOMA C 00CKET NC._5,0-112
(
1.0 _I_NTRODUCTION
,The University of Oklahoma (U0) sutaitted an application, pursuant to 10 t/R 50.90, for a change of status from operatir.g to possession-only for -
their 100 watt (thermal) AGN-211P research reactor on October 15, 1987 and supplemented on November 19, 1987 and February 18, 1988. The anolication included evised technical specifications, physical security Ni and requested that an exemption from the requireme7ts of an e.e gency plan be granted.
2.0 EVALUATION ,
The reactor has'not operated since April 1986 All fuel has been removed from the rev. tor and has been placed in approved storage containers, which have a Keff less than 0.8 and contain less than 400 grams of U-235 each. The containers are stored in locked reems in the reactor building and the ,torage stray (by technical specification 5.2) is such that Keff u no creater tean 0.6 for all conditions of moderation and reflection. As of July 1987, radiation levels at the surface of the fuel storage container were less than 2 mr/hr and less than 0.5 mr/hr at one meter fron the fuel. The licensee is in the process of transferring the fuel back to the Department of Energy and expects that this process will be completed by the end of May 1988.
The 7echnical Specifications have been modified extensively to reflect the "possession-only" status requested by UO. In general, those Technical Specifications relating to reactor operation, performance, safety surwillsnee, and r0 lated reporting were deleted. Those relating to staff and popuhtion safety, surveillance, monitoring, organization, and related reporting requirements have been retained. ,All specifications relating to 1.1-core fuel, coolant, and moderttor systems; reacter control and safety syst(mst and in-core experiments tavp been deleted. Since the reactor cannot he fiseled or operated, these 1tems are no longer relevant and technical specifications that address them are not meaningful. Those technical specifications thaf, pertain to the possession-only status of the facility were retairkd. They include the radiation monitoring systcm and administrative funct'ons. The amended technical specificatSow will continue to ensure that the various activities permitted under the possesrlon-only license htatur. will be conducted without significant risk to the h p1th and safety Of onsite personnel or the public or to the environment. <
8903140303 000300 ADOCK 0500 gDR . -. .- . _. _
The licensee has requested an exemption from the requirements of an emergency plan required by 10 CFR 50.54(r). A criticality accident ,
cannot occur since the fuel has been removed from the reactor and will .a maintained with a keff less than 0.8 for any combinations of fuel or ,
moderator. Under these circumstances, an emergency plan would not serve the underlying purpose of 10 CFR 50.54(r) and, therefore, the staff finds that a specific exemption under 10 CFR 50.12(a)(2)(ii) is appropriate, and is granted.
The revised physical security plan has been reviewed and has been found to be acceptable.
3.0 ENVIRONMENTAL CONSIDERATION
This amendment involves changes in the installation or use of facility components located within the restricted area as defined in 10 CFR Part '
20 and changes in inspection and surveillance requirements. The staff -
has determined that the amendment involves no significant hazards consideration (as discussed below), there is no significant change in thaj types or significant increase in the amounts of any effluents that may be released offsite, and there is no significant increase in individual or cumulative occupational radiation exposure. Accordingly, this emendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of this amendment.
4.0 CONCLUSION
The staff concludes that amending this license to a possession-only status is appropriate. The staff has further concluded, based on the considerations discussed above, that: (1) because the amendment does not involve a significant increase in the probability or consequences of an accidente previously evaluated, or create the possibility of a new or
- different kind of accident from any accident previously evaluated, or involve a significant reduction in a margin of safety, the amendment does not involve a significant hazards consideration, (2) there is reasonable assurance that the health and safety of the public will not be endangered by the proposed activities, and (3) such activities will be conducted in compliance with the Commission's regulations and the issuance of this amendment will not be inimical to the comon defense and security or the health and safety of the public.
f Principal Contributor: Theodore S. Michaels Dated: March 8, 1988
)
\
-