Page 1 of 52 DSAR-11.1 Radioactive Waste and Radiation Protection and Monitoring Radioactive Waste Disposal System Rev 4 Safety Classification:

Usage Level:

Safety Information Change No.:

EC 69954 Reason for Change:

Updated to reflect LWTF reanalysis due to reduced EAB.

Preparer:

C. Waszak Fort Calhoun Station

DSAR-11.1 Information Use Page 2 of 52 Radioactive Waste Disposal System Rev. 4 Table of Contents

11.

RADIOACTIVE WASTE AND RADIATION PROTECTION AND MONITORING..... 5 11.1 Radioactive Waste Disposal System........................................................................5 11.1.1 Design Bases.............................................................................................5 11.1.1.1 General................................................................................. 5 11.1.1.2 Radioactive Waste Inventory................................................ 6 11.1.1.3 Deleted................................................................................. 6 11.1.1.4 Deleted................................................................................. 6 11.1.2 Liquid Wastes............................................................................................7 11.1.2.1 Sources and Characteristics of Liquid Wastes..................... 7 11.1.2.2 Collection and Handling of Liquid Wastes............................ 8 11.1.2.3 Liquid Waste Treatment...................................................... 13 11.1.2.4 Liquid Waste Disposal........................................................ 14 11.1.2.5 System Components.......................................................... 14 11.1.2.6 System Operation............................................................... 19 11.1.2.7 Design Evaluation............................................................... 19 11.1.2.8 Availability and Reliability................................................... 31 11.1.2.9 Operation............................................................................ 32 11.1.2.10 Tests and Inspections......................................................... 32 11.1.3 Gaseous Wastes..................................................................................... 33 11.1.3.1 General............................................................................... 33 11.1.3.2 Sources of Waste Gas........................................................ 34 11.1.3.3 Processing of Waste Gases............................................... 36 11.1.3.4 Deleted............................................................................... 36 11.1.3.5 Deleted............................................................................... 36 11.1.3.6 Deleted............................................................................... 36 11.1.3.7 Design Evaluation............................................................... 36 Radiological Gases Released from Auxiliary Building............................ 36 11.1.3.8 Availability and Reliability................................................... 46 11.1.3.9 Operation............................................................................ 47 11.1.3.10 Tests and Inspections......................................................... 47 11.1.4 Solid Wastes............................................................................................ 48 11.1.4.1 General............................................................................... 48 11.1.4.2 Sources of Solid Waste...................................................... 48 11.1.4.3 System Components.......................................................... 50 11.1.4.4 System Operation............................................................... 51 11.1.4.5 Design Evaluation............................................................... 51 11.1.4.6 Availability and Reliability................................................... 52 11.1.4.7 Tests and Inspections......................................................... 52

DSAR-11.1 Information Use Page 3 of 52 Radioactive Waste Disposal System Rev. 4 List of Tables Table 11.1 Radioactive Waste Volumes............................................................................ 6 Table 11.1 Reactor Coolant Waste Volume Estimates.................................................... 9 Table 11.1 Liquid Waste Volumes.................................................................................. 10 Table 11.1 Component Design Data, Waste Disposal System Tanks............................ 15 Table 11.1 Component Design Data, Waste Disposal System Pumps.......................... 16 Table 11.1 Component Design Data, Waste Disposal System Process Equipment...... 18 Table 11.1 Fission Product Activity in the Waste Treatment System at STP................. 21 Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits..................................................................................................................................... 26 Table 11.1 Deleted......................................................................................................... 35 Table 11.1 Deleted......................................................................................................... 36 Table 11.1 Maximum Gaseous Release, Spent Regenerant Tanks............................... 38 Table 11.1 Annual Releases of Radioactive Gases and Particulates............................. 40 Table 11.1 Solid Waste Volumes................................................................................... 50

DSAR-11.1 Information Use Page 4 of 52 Radioactive Waste Disposal System Rev. 4 List of Figures The following figures are controlled drawings and can be viewed and printed form the applicable listed aperture card.

Figure No.

Title Aperature Card 11.1-1 Calculated Maximum Source Concentration Downstream of Fort Calhoun Station...................................3657

DSAR-11.1 Information Use Page 5 of 52 Radioactive Waste Disposal System Rev. 4

11.

RADIOACTIVE WASTE AND RADIATION PROTECTION AND MONITORING 11.1 Radioactive Waste Disposal System 11.1.1 Design Bases 11.1.1.1 General The radioactive waste disposal system (RWDS) is designed to protect plant personnel and the public from exposure to radioactive wastes in accordance with 10 CFR Part 20; 10 CFR 50, Appendix I; 40 CFR Part 190; 10 CFR 50 Appendix A General Design Criterion 60, and Draft GDC Criteria 17 and 18; 10 CFR 50 Appendix B for reviews and audits; and the intent of NUREG-1301 (see Section 11.3).

The RWDS has been reviewed against the requirements of NUREG-1301 "Offsite Dose Calculation Manual Guidance:

Standard Radiological Effluent Controls for Pressurized Water Reactors". As a result of the review, Technical Specifications were approved to govern effluent instrumentation calibration and operation, allowable dose rates, approved methodology to calculate dose rates, limiting conditions for operating the RWDS, requirements for environmental monitoring programs and requirements for maintaining records, ensuring adequate review and audits and reporting information as required. The details of RETS commitments for the liquid, gaseous and solid radioactive treatment systems are discussed in Sections 11.1.2, 11.1.3, and 11.1.4. RETS commitments for Radiation Monitoring are discussed in Section 11.2.3. Section 11.3 addresses overall requirements such as the Offsite Dose Calculation Manual (ODCM), reporting requirements, and summarizes the requirements of RETS as they are addressed by the Technical Specifications.

NRC Generic Letter 89-01 allowed licensees to remove the procedural details of the Radiological Effluent Technical Specifications from the Technical Specifications and place them in the ODCM. The administrative section of Technical Specifications was updated to include the programmatic controls necessary to ensure compliance with Federal Regulations. This change has placed the procedural requirements for equipment, sampling, analyses, monitoring, and dose limitations in the ODCM.

Reference to specific sections of the ODCM will not be made in this document.

DSAR-11.1 Information Use Page 6 of 52 Radioactive Waste Disposal System Rev. 4 The RWDS includes equipment to collect, store, process and treat as required, monitor, and dispose of liquid, solid, and gaseous radioactive wastes.

The RWDS was designed to process and remove radioactive wastes from the plant adequately and safely when 1 percent of the core fuel elements have failed and corrosion and fission product concentrations in the reactor coolant were at design values. The design of the RWDS was based on the plant operating cycle.

Note: Since Fort Calhoun Station is permanently shutdown and defueled, the radioactive waste generation and removal needs are reduced. As a result, radioactive waste estimates for a running plant are considered to bound the needs of the decommissioning station.

11.1.1.2 Radioactive Waste Inventory The waste volumes that were estimated to accumulate during one refueling cycle are shown in Table 11.1-2. Since Fort Calhoun Station is permanently shutdown and defueled, the radioactive waste generation and removal needs are reduced. As a result, radioactive waste estimates for an operating plant are considered to bound the needs of the decommissioning station.

Table 11.1 Radioactive Waste Volumes Volume (ft3/cycle) Basis Liquids 150,000 Processed liquid at 70°F Gases 51,135 At 70°F and 1 atm Solids 5,000 Dry Activated Waste, filters, spent resins, depleted filtration/ion exchange media 11.1.1.3 Deleted 11.1.1.4 Deleted

DSAR-11.1 Information Use Page 7 of 52 Radioactive Waste Disposal System Rev. 4 11.1.2 Liquid Wastes 11.1.2.1 Sources and Characteristics of Liquid Wastes The liquid waste collection and storage system is divided into two sections; auxiliary systems process wastes, and hotel wastes.

The original sources of liquid wastes and their routing to the collection points are shown in the flow diagrams, P&ID's 11405-M-6, 11405-M-7 and 11405-M-99.

Auxiliary Systems Process Wastes The principal sources for the liquids are:

a.

Spent regenerant;

b.

Auxiliary building floor drain header;

c.

Auxiliary building sump flows;

d.

Laboratory and decontamination area drain header;

e.

Spent resin sluice water;

f.

Monitor tanks contaminated return flows;

g.

Waste holdup tank relief valves;

h.

Containment building sump flows.

i.

Radioactive Waste Processing Building sump flows.

j.

Chemical and Radiation Protection Building Laboratory drains.

k.

Fuel transfer canal drains and safety injection system drains.

Wastes from these sources are subject to contamination. They are collected in the spent regenerant tanks which are vented to the auxiliary building ventilation system.

DSAR-11.1 Information Use Page 8 of 52 Radioactive Waste Disposal System Rev. 4 Aerated Domestic Wastes The principal sources for these liquids are:

a.

Laundry facility drains

b.

Shower drains

c.

Hand sink drains These wastes all originate in the auxiliary building and are transported in the laundry drain header which discharges to the hotel waste tanks. Domestic wastes are normally low in activity.

11.1.2.2 Collection and Handling of Liquid Wastes Reactor Coolant Liquids The volume of waste entering the radioactive waste disposal system from this source was estimated for a core cycle and shown in Table 11.1-10.

NOTE: This estimate supports the radiological consequences analysis in DSAR section 14.20 which is for a running plant. As such the cycle waste volume estimates are being maintained even though Fort Calhoun Station is permanently shutdown and actual radioactive waste generation and removal needs are reduced.

DSAR-11.1 Information Use Page 9 of 52 Radioactive Waste Disposal System Rev. 4

  • This value is used to conservatively calculate the environment radioactive release inventories for a liquid waste tank failure in calculation FC06802.

Table 11.1 Reactor Coolant Waste Volume Estimates Reactor Coolant Discharged to Waste Between Refuelings Based on Postulated Events During an Equilibrium Core Cycle Elapsed Time Waste Volume (equivalent full (liquid @ 70°F, Event power days) ft3/event)

1.

Reactor refueled at 70°F through heatup to 570°F, initial full power and xenon equilibrium 2

4,230

2.

Cold shutdown No. 1 and restart following attainment of samarium equilibrium 23 3,278

3.

Hot shutdown No. 1 and restart 118 1,167

4.

Hot shutdown No. 2 and restart 168 1,717

5.

Hot shutdown No. 3 and restart 248 1,938 6

Cold shutdown No. 2, partial drain for maintenance and restart 254 9,463

7.

Hot shutdown No. 4 and restart 490 5,671

8.

Initiate operation of deborating demineralizer No.3 500

9.

Cold shutdown 530 763 Total from events 28,227 Total from control of coolant boron concentration during 530 full power days 24,514 Total per equilibrium cycle 52,741*

Assumptions: (a) Base loaded plant; boron adjustment for load following is not required.

(b) Reactivity effect of xenon during shutdown is not compensated by boron adjustment.

Other reactor coolant type wastes are variable in flow and occur chiefly as periodic drains, leak-offs, and occasional relief valve discharges. All liquid waste volume estimates are shown in Table 11.1-11.

DSAR-11.1 Information Use Page 10 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Liquid Waste Volumes Volume liquid @ 70°F, (ft3/482 full power days)

Remarks

1.

Reactor Coolant Wastes Boron control 52,741 From Table 11.1-10 Reactor coolant pump seal 66 leak-offs CEDM leak-offs 1,204 Design value for RWDS purpose Charging pump seal leak-offs 3,000 Stored energy safety injection 1,000 Flow to RWDS based tanks, check valve leak-offs on 0.1% leak-off Purification filters drain 20 2 replacements per cycle CVCS ion exchangers, drain 400 3 parts sluice water and sluice water per part resin Reactor coolant and CVCS 16,494 Continuous analyzer sample wastes operation plus normal sampling Valve leak-offs and safety relief)

Valve discharge) normally Quench tank drain) zero

2.

Spent Regenerant Chemicals Deborating exchangers 700 Based on two regenerations per cycle

3.

Hotel Wastes 49,482

4.

Spent Fuel Pool Cooling System Filter drain 50 Two replacements per cycle Ion exchanger drain and 60 sluice water

5.

Radiochemical Lab Drains Accounted for in sampling wastes

6.

Secondary Plant Steam 16,494 Normally zero Generator Blowdown Assumes discharge of water inventory of two steam generators per year.

Total 141,711 ft3 Rounded to 150,000 ft3

DSAR-11.1 Information Use Page 11 of 52 Radioactive Waste Disposal System Rev. 4 Reactor coolant liquids are collected as follows:

a.

Deleted

b.

Auxiliary building sump tank (WD-25): This tank is the collection point for equipment drains in the auxiliary building (equipment drain header). The ABST is vented and drained. All incoming liquid is directed to the Room 23 sump, then pumped to the spent regen tanks.

c.

Waste holdup tanks (WD-4A/B/C): These tanks receive the output from the spent regenerant tanks (WD-13A/B). The function of these tanks is to provide temporary storage capacity. Three waste holdup tanks are provided.

When one of the waste holdup tanks becomes filled, the waste flow is diverted to a second tank. The accumulated batch may be then thoroughly mixed by means of a recirculation pump. The recirculation pump is also capable of transferring the contents of one tank to another. Normally, the third waste holdup tank is on standby, ready to receive waste flow if the second tank becomes filled before the contents of the first tank have been discharged.

Two waste holdup pumps take suction from the tanks and deliver the waste to the treatment inlet header or to the monitor tanks.

The two pumps are manually controlled from the waste treatment control panel (see Section 7.6.3).

DSAR-11.1 Information Use Page 12 of 52 Radioactive Waste Disposal System Rev. 4 Auxiliary Systems Process Wastes These wastes are collected in the spent regenerant tanks and include: floor drain header flow from the auxiliary building, sump flows from the auxiliary building, radioactive waste processing and containment buildings, and spent resin sluice water. Gravity drains from the floor drain header and the drain header above floor elevation 971'-0" are collected directly in the spent regenerant tanks, whereas gravity drains from the sub-basement floor elevation and floor drains within the containment are collected in sumps and are delivered automatically by level-controlled pumps to the spent regenerant tanks.

Two spent regenerant tanks are provided and they are constructed of type 304 stainless steel due to the variety of liquids they might contain. Connection to the caustic dilution tank is provided for neutralization purposes, if required. The tanks are vented to the building ventilations exhaust system. Checked vent lines permit atmospheric inflow to the tanks on falling liquid level and exhaust to the ventilation system on rising liquid level.

A completed waste batch is normally delivered to the waste holdup tanks or the treatment inlet header. Delivery is made by two spent regenerant pumps, manually controlled, that also serve to mix the tank contents by recirculation. The tanks can also be transferred directly to the monitor tanks or the other spent regenerant tank or be recirculated and sampled if desired.

Hotel Wastes These flows are chiefly from the laundry drain header, are usually low in activity, and are collected in the hotel waste tanks.

A filter has been placed in this line to prevent the passage of radioactive solids to the hotel waste tank from the laundry washers.

Two hotel waste tanks are provided, each designed to hold approximately one day's hotel waste flow. They are constructed of carbon steel, since corrosive liquids do not enter the laundry drain header. The tanks are simply vented to the atmosphere.

DSAR-11.1 Information Use Page 13 of 52 Radioactive Waste Disposal System Rev. 4 Mixing is accomplished by use of the hotel waste pumps as circulators, after which the waste batch is sampled and analyzed.

The batch is then delivered to either the treatment inlet header or the monitor tanks or the overboard discharge header by the two manually controlled hotel waste pumps.

11.1.2.3 Liquid Waste Treatment General The RWDS is designed to provide filtration, and demineralization as needed to ready the waste for ultimate disposal. The process flow diagrams are shown in P&ID's 11405-M-8 and 11405-M-9.

Filtration Suspended solids are removed by two waste filters. Solids are retained on the disposable filter element. Filter effluent is directed to the next treatment step or to the monitor tanks.

Filtration/Ion-Exchange Filtration/ion-exchange (FIX) services are presently being used as the preferred method for liquid waste treatment and is located in the Radioactive Waste Processing Building.

The FIX system is designed to remove specific radioisotopes in the liquid waste stream.

The treated effluent from the FIX system is transferred to the monitor tanks.

Monitor Tanks The two monitor tanks normally receive processed liquid wastes from the waste holdup tanks. The wastes are sampled and analyzed isotopically to confirm acceptability for controlled release to the overboard header. One tank can be undergoing recirculation for sampling while the other tank is being released to the overboard header.

DSAR-11.1 Information Use Page 14 of 52 Radioactive Waste Disposal System Rev. 4 11.1.2.4 Liquid Waste Disposal During releases of radioactive liquid waste, the equipment and conditions shall be in accordance with the ODCM. The doses resulting from liquid releases shall not exceed, during any calendar year, 3 millirem to the total body (10 millirem to any organ) as required by 10 CFR Part 50 Appendix I.

The requirements for sample monitoring and testing prior to release and the requirements to ensure monitors are calibrated are included in the ODCM. Records of liquid releases must be maintained and are subject to the review, audits, and reporting requirements discussed in Section 11.3.

The overboard header is the only path through which the liquid rad wastes can be released from the containment, auxiliary, Radioactive Waste Processing and CARP buildings. It receives liquid from the monitor tanks, & the hotel waste tanks. The overboard header originates at the monitor tanks or the hotel waste tanks and terminates in the condenser circulating water discharge tunnel, entering the tunnel in the section downstream of the warm water recirculation return (see P&ID 11405-M-257).

Effluent from the monitor tanks or the hotel waste tanks is moved by two monitor tank pumps or hotel waste pumps and the flow rate is monitored on a recorder.

The overboard header is equipped with a radiation monitor that interrupts flow if waste activity reaches a predetermined setpoint (see Section 11.2.3).

11.1.2.5 System Components The various components of the RWDS are divided into three groups for convenience of listing; tanks, pumps, and process equipment. These are shown in Tables 11.1-12, 13, and 14.

DSAR-11.1 Information Use Page 15 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Component Design Data, Waste Disposal System Tanks Pressure, Temperature psig °F No. Installed/ Tank Capacity Design/

Design/

Tank Item No. gallons/ft3 Operating Operating Material* Code Waste Holdup 3/WD-4A, 45,800/6,100 15/Atmos 200/120 CS ASME Section III, Tanks B&C Class C, Feb. 1968 Spent Regenerant 2/WD-13A&B 5,530/739 5/Atmos 200/70 304 SS ASME Section VIII, Tanks Feb. 1968 Hotel Waste Tanks 2/WD-15A&B 1,200/160 15/Atmos 200/140 CS ASME Section VIII, Feb. 1968 Monitor Tanks 2/WD-22A&B 6,770/905 5/Atmos 200/140 304 SS ASME Section VIII, Feb. 1968 Auxiliary Building 1/WD-25 700/95 25/Atmos 200/120 304 SS ASME Section VIII, Sump Tank Feb. 1968 Spent Resin Storage 1/WD-33 3,250/434 25/Atmos 250/120 304 SS ASME Section VIII, Tank Feb. 1968 Waste Metering Tank 1/WD-46 688/92 Atmos 316 SS ASME Section VIII, Feb. 1968

  • SS= Stainless Steel, CS= Carbon Steel

DSAR-11.1 Information Use Page 16 of 52 Radioactive Waste Disposal System Rev. 4 Pumps were designed in accordance with the Standards of the Hydraulic Institute and all motors conformed to NEMA standards.

Materials were in accordance with the appropriate ASTM specifications. Other codes and standards are listed in the tables referenced above.

Table 11.1 Component Design Data, Waste Disposal System Pumps No. Installed/

Fluid Side Pump Item No.

Type Capacity Material*

Containment 2/WD-3A&B Vertical 50 gpm @ 40 ft.

AI Sump Pumps Centrifugal Waste Holdup 2/WD-5A&B Horizontal 50 gpm @ 177 ft.

316 SS Tank Pumps Centrifugal, Canned Rotor Waste Holdup 1/WD-6 Horizontal 500 gpm @ 85 ft.

AI Recirculation Centrifugal Pump Spent Reg. Pumps 2/WD-14A&B Horizontal 50 gpm @ 157 ft.

304 SS Centrifugal Hotel Waste 1/WD-16A Horizontal 50 gpm @ 120 ft. AI Pumps Centrifugal 1/WD-16B Horizontal 50gpm @ 130 ft.

AI Centrifugal

DSAR-11.1 Information Use Page 17 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1-13 (Continued)

No. Installed/

Fluid Side Pump Item No.

Type Capacity Material*

Monitor Tank 2/WD-23A&B Horizontal 50 gpm @ 160 ft.

304 SS Pumps Centrifugal Auxiliary Bldg.

2/WD-26A&B Horizontal 35 gpm @ 110 ft.

304 SS Sump Tank Pumps Centrifugal Auxiliary Bldg.

4/WD-27A&B, Vertical 20 gpm @ 34 ft.

CI Room 21 and 22 40A&B Centrifugal Sump Pumps Auxiliary Bldg.

2/WD-41A&B Vertical 20 gpm @ 36 ft.

CI Room 23 Centrifugal Sump Pumps Spent Resin 1/WD-34 Horizontal 30 gpm @ 106 ft.

304 SS Pump Centrifugal Radioactive Waste 4/WD-30A&B, Vertical 65 gpm @ 40 ft.

304SS Processing Bldg.

WD/31A&B Centrifugal Sump Pumps

DSAR-11.1 Information Use Page 18 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Component Design Data, Waste Disposal System Process Equipment Waste Filters, Item No's WD-17A&B Description Number 2

Type Expendable element pressure type Materials of Construction 304 stainless steel vessel Vessel Design Pressure, psig 150 Vessel Design Temperature, °F 250 Vessel Code ASME Section III, Class C, Feb.

1968 Flow Rate (filter), each, gpm 150 Average Efficiency, % (particles 50 microns) 43

DSAR-11.1 Information Use Page 19 of 52 Radioactive Waste Disposal System Rev. 4 11.1.2.6 System Operation The operation of the liquid waste section of the RWDS involves a combination of automatic and manual controls. The flow of liquids from one of the collection tanks (the auxiliary building sump tank) and the four drain sumps can be controlled automatically by liquid level. The control panels are described in Section 7.6.3.

At the waste holdup tanks, the hotel waste tanks, the spent regenerant tanks, and the monitor tanks, the operator must decide where to send the contents of a tank. The operator can send it through various tanks, filters, or the Filtration Ion Exchange System, depending on the processing required. Therefore, the flow leaving these tanks is manually controlled at the waste disposal control panel.

The waste filters are equipped with differential pressure indication and the filters are replaced when a predetermined pressure drop is reached.

The filtration/ion exchange system is designed to provide any flow logic through the system's pressure vessels. The flow logic is dependent upon the type of waste to be processed and is accomplished by manually valving the hose setup between vessels.

11.1.2.7 Design Evaluation The anticipated performance of the liquid waste system has been calculated in accordance with the following assumptions.

DSAR-11.1 Information Use Page 20 of 52 Radioactive Waste Disposal System Rev. 4

  • These values are used to conservatively estimate the environmental radioactivity release inventories in calculation FC06802.

The maximum cycle quantity of liquid waste containing significant activity was approximately 141,711 cu. ft. As shown in Table 11.1-10, 52,741* cu. ft. of the total liquid waste was from the chemical and volume control system and had already passed through the purification ion exchangers. The activity of this liquid waste was assumed to be reduced by a factor of 10 for each nuclide except rubidium, molybdenum, noble gases and tritium for which a factor of unity has been assumed. An additional volume of 22,184* cu. ft., shown in Table 11.1-11, had an activity equal to that of reactor coolant. Hotel wastes are low in activity and with the addition of a filter which collects radioactive solids, will remain low in activity at discharge to the hotel waste tanks. Waste volumes resulting from steam generator blowdown while normally zero, was estimated on the basis that primary-to-secondary leakage requires that the zero load liquid inventory of both steam generators (6,000 cu. ft.) was discharged to the RWDS once per cycle and that the activity was consistent with having operated for 45 days with a 1 gph primary-secondary leak and one percent fuel failure based on historical calculations Ref. 11.4.16.

The two waste filters are designed to remove insoluble corrosion products, some of which may be radioactive. However, no credit has been assumed for these filters in the system evaluation. The Filtration Ion Exchange System average total decontamination factor is 364. The normal liquid waste holdup time is 30 days.

The fission product activities in the liquid waste treatment system are shown in Table 11.1-15.

NOTE: This estimate supports the radiological consequences analysis in DSAR section 14.20 which is for a running plant. As such the cycle waste volume estimates are being maintained even though Fort Calhoun Station is permanently shutdown and actual radioactive waste generation and removal needs are reduced.

Dilution flow rates are also reduced due to the plants shutdown and permanently defueled condition. Administrative measures account for reduced dilution flow by limiting the undiluted effluent discharge flow rate. This ensures that the concentration of diluted radioactive effluents remain within the limits specified in 10 CFR Part 20. The capacity to remove liquid waste at these reduced flow rates remains well above the expected average annual liquid waste discharge.

DSAR-11.1 Information Use Page 21 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Fission Product Activity in the Waste Treatment System at STP NUCLIDE SPECIFIC ACTIVITY AT STP with ion exchange RCS Concentration Ci/cc LRWS As-Received Conentration Ci/cc Annual 1 Day Decay Ci/cc Annual 30 Day Decay Ci/cc Kr-83m 2.20E+00 2.20E+00 1.72E-04 5.87E-119 Kr-85 1.94E-01 1.94E-01 1.33E-01 1.33E-01 Kr-85m 4.67E+00 4.67E+00 7.85E-02 1.37E-48 Kr-87 9.37E+00 9.37E+00 1.35E-05 2.69E-170 Kr-88 1.31E+01 1.31E+01 2.58E-02 4.50E-76 Kr-89 1.64E+01 1.64E+01 2.17E-136 0.00E+00 Kr-90 1.77E+01 1.77E+01 0.00E+00 0.00E+00 Xe-131m 1.63E+00 1.63E+00 1.06E+00 1.96E-01 Xe-133 1.13E+02 1.13E+02 6.79E+01 1.47E+00 Xe-133m 1.09E+00 1.09E+00 5.49E-01 5.68E-05 Xe-135 1.30E+01 1.30E+01 1.45E+00 1.75E-23 Xe-135m 7.27E+00 7.27E+00 2.26E-28 0.00E+00 Xe-137 3.18E+01 3.18E+01 6.72E-113 0.00E+00 Xe-138 3.03E+01 3.03E+01 3.45E-30 0.00E+00 Br-82 7.49E-04 2.75E-03 1.18E-03 1.37E-09 Br-83 3.16E-02 1.16E-01 7.79E-05 4.09E-92 Br-85 6.66E-02 2.44E-01 1.65E-152 0.00E+00 I-129 9.16E-09 3.36E-08 2.31E-08 2.31E-08 I-130 5.52E-03 2.02E-02 3.63E-03 4.09E-20 I-131 1.19E+00 4.35E+00 2.75E+00 2.25E-01 I-132 3.55E-01 1.30E+00 6.16E-04 1.19E-95 I-133 5.02E-01 1.84E+00 5.70E-01 4.84E-11 I-134 5.61E-01 2.06E+00 8.16E-09 9.33E-248 I-135 4.77E-01 1.75E+00 9.57E-02 1.25E-33 I-136 2.24E-01 8.19E-01 0.00E+00 0.00E+00 Cs-132 9.27E-06 3.40E-05 2.10E-05 9.44E-07 Cs-134 4.17E-02 1.53E-01 1.05E-01 1.02E-01 Cs-134m 9.45E-03 3.46E-02 7.86E-05 8.16E-77 Cs-135m 9.75E-03 3.57E-02 1.64E-10 1.19E-247 Cs-136 1.30E-02 4.77E-02 3.12E-02 6.77E-03 Cs-137 3.13E-02 1.15E-01 7.91E-02 7.89E-02 Cs-138 4.70E-01 1.72E+00 4.12E-14 0.00E+00 Cs-139 4.39E-01 1.61E+00 1.96E-47 0.00E+00 Cs-140 3.95E-01 1.45E+00 0.00E+00 0.00E+00 Rb-86 4.12E-03 4.12E-03 2.73E-03 9.30E-04 Rb-88 1.93E+00 1.93E+00 5.61E-25 0.00E+00 Rb-89 2.53E+00 2.53E+00 5.36E-29 0.00E+00 Rb-90 2.35E+00 2.35E+00 1.78E-170 0.00E+00 Rb-90m 7.19E-01 7.19E-01 8.06E-102 0.00E+00 Ag-110 4.07E-02 1.49E-01 0.00E+00 0.00E+00

DSAR-11.1 Information Use Page 22 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Fission Product Activity in the Waste Treatment System at STP NUCLIDE SPECIFIC ACTIVITY AT STP with ion exchange RCS Concentration Ci/cc LRWS As-Received Conentration Ci/cc Annual 1 Day Decay Ci/cc Annual 30 Day Decay Ci/cc Ag-110m 1.02E-03 3.73E-03 2.56E-03 2.36E-03 Ag-111 1.49E-02 5.47E-02 3.43E-02 2.31E-03 Ag-112 6.84E-03 2.51E-02 8.64E-05 1.68E-71 As-76 4.96E-06 1.82E-05 6.65E-06 7.32E-14 Cd-115 2.03E-03 7.43E-03 3.75E-03 4.53E-07 Cd-115m 9.39E-05 3.44E-04 2.33E-04 1.49E-04 Ga-72 4.05E-06 1.48E-05 3.14E-06 4.37E-21 Ge-77 1.72E-04 6.30E-04 9.95E-05 2.89E-23 In-115m 2.03E-03 7.43E-03 1.26E-04 2.54E-51 Sb-122 2.40E-04 8.78E-04 4.68E-04 2.74E-07 Sb-124 1.86E-04 6.82E-04 4.64E-04 3.33E-04 Sb-125 2.15E-03 7.89E-03 5.43E-03 5.32E-03 Sb-127 2.13E-02 7.80E-02 4.49E-02 2.43E-04 Sb-129 7.85E-02 2.88E-01 4.52E-03 1.12E-50 Sb-130 2.61E-02 9.57E-02 7.03E-13 0.00E+00 Sb-130m 1.09E-01 4.01E-01 4.45E-70 0.00E+00 Sb-131 1.93E-01 7.06E-01 6.98E-20 0.00E+00 Sb-132 1.14E-01 4.18E-01 1.87E-104 0.00E+00 Sb-132m 1.11E-01 4.07E-01 4.63E-156 0.00E+00 Sb-133 1.63E-01 5.97E-01 1.81E-174 0.00E+00 Se-83 1.47E-02 5.38E-02 1.36E-21 0.00E+00 Sn-121 1.99E-03 7.28E-03 2.71E-03 4.92E-11 Sn-123 1.56E-04 5.73E-04 3.93E-04 3.36E-04 Sn-125 1.22E-03 4.47E-03 2.86E-03 3.56E-04 Sn-127 8.56E-03 3.14E-02 7.85E-06 1.40E-105 Te-127 2.10E-02 7.69E-02 8.94E-03 3.53E-25 Te-127m 3.49E-03 1.28E-02 8.75E-03 7.28E-03 Te-129 7.49E-02 2.75E-01 1.12E-07 2.95E-188 Te-129m 1.51E-02 5.53E-02 3.73E-02 2.05E-02 Te-131 2.05E-01 7.50E-01 2.38E-18 0.00E+00 Te-131m 4.86E-02 1.78E-01 7.05E-02 7.34E-09 Te-132 3.49E-01 1.28E+00 7.12E-01 1.49E-03 Te-133 2.75E-01 1.01E+00 1.48E-35 0.00E+00 Te-133m 2.27E-01 8.30E-01 8.59E-09 1.17E-235 Te-134 4.57E-01 1.68E+00 4.94E-11 0.00E+00 Ba-137m 2.98E-02 1.09E-01 1.13E-171 0.00E+00 Ba-139 4.49E-01 1.65E+00 8.57E-06 2.65E-154 Ba-140 4.49E-01 1.65E+00 1.07E+00 2.22E-01 Ba-142 3.91E-01 1.43E+00 1.28E-41 0.00E+00 Sr-89 2.63E-01 9.63E-01 6.54E-01 4.40E-01

DSAR-11.1 Information Use Page 23 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Fission Product Activity in the Waste Treatment System at STP NUCLIDE SPECIFIC ACTIVITY AT STP with ion exchange RCS Concentration Ci/cc LRWS As-Received Conentration Ci/cc Annual 1 Day Decay Ci/cc Annual 30 Day Decay Ci/cc Sr-90 2.45E-02 8.98E-02 6.18E-02 6.17E-02 Sr-91 3.26E-01 1.19E+00 1.43E-01 1.42E-23 Sr-92 3.41E-01 1.25E+00 1.86E-03 9.41E-81 Sr-93 3.79E-01 1.39E+00 3.95E-59 0.00E+00 Sr-94 3.75E-01 1.37E+00 0.00E+00 0.00E+00 Mo-99 4.57E+00 4.57E+00 2.45E+00 1.63E-03 Mo-101 4.13E+00 4.13E+00 5.89E-30 0.00E+00 Pd-109 9.33E-02 3.42E-01 7.00E-02 3.59E-17 Rh-103m 3.88E-01 1.42E+00 1.85E-08 2.06E-232 Rh-105 2.49E-01 9.13E-01 3.93E-01 4.68E-07 Rh-105m 7.61E-02 2.79E-01 0.00E+00 0.00E+00 Rh-106 1.54E-01 5.64E-01 0.00E+00 0.00E+00 Ru-103 3.88E-01 1.42E+00 9.63E-01 5.77E-01 Ru-106 1.40E-01 5.14E-01 3.53E-01 3.35E-01 Tc-99m 4.04E-01 1.48E+00 6.41E-02 8.97E-37 Tc-101 4.13E-01 1.51E+00 3.15E-31 0.00E+00 Tc-104 3.20E-01 1.17E+00 1.68E-24 0.00E+00 Tc-105 2.65E-01 9.72E-01 6.32E-58 0.00E+00 Ce-141 4.14E-01 1.52E+00 1.02E+00 5.52E-01 Ce-143 3.91E-01 1.43E+00 5.96E-01 2.67E-07 Ce-144 3.20E-01 1.17E+00 8.05E-01 7.50E-01 Np-239 5.14E+00 1.88E+01 9.66E+00 1.90E-03 Pu-238 8.32E-04 3.05E-03 2.10E-03 2.10E-03 Pu-239 1.07E-04 3.92E-04 2.70E-04 2.70E-04 Pu-240 1.40E-04 5.12E-04 3.53E-04 3.53E-04 Pu-241 3.60E-02 1.32E-01 9.09E-02 9.06E-02 Pu-242 5.93E-07 2.17E-06 1.50E-06 1.50E-06 Th-228 9.33E-10 3.42E-09 2.35E-09 2.29E-09 Am-241 4.33E-05 1.59E-04 1.09E-04 1.09E-04 Cm-242 1.22E-02 4.49E-02 3.08E-02 2.72E-02 Cm-244 1.18E-03 4.34E-03 2.99E-03 2.98E-03 Eu-154 1.82E-03 6.67E-03 4.59E-03 4.56E-03 Eu-155 7.91E-04 2.90E-03 1.99E-03 1.97E-03 Eu-156 5.71E-02 2.09E-01 1.38E-01 3.67E-02 Eu-157 6.06E-03 2.22E-02 5.12E-03 8.12E-17 Eu-158 2.13E-03 7.80E-03 1.94E-12 2.94E-286 Eu-159 1.08E-03 3.94E-03 3.09E-27 0.00E+00 Gd-159 1.46E-03 5.34E-03 1.50E-03 7.76E-15 Ho-166 2.02E-05 7.41E-05 2.74E-05 4.19E-13 La-140 4.61E-01 1.69E+00 7.69E-01 4.84E-06

DSAR-11.1 Information Use Page 24 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Fission Product Activity in the Waste Treatment System at STP NUCLIDE SPECIFIC ACTIVITY AT STP with ion exchange RCS Concentration Ci/cc LRWS As-Received Conentration Ci/cc Annual 1 Day Decay Ci/cc Annual 30 Day Decay Ci/cc La-141 4.11E-01 1.51E+00 1.49E-02 5.45E-56 La-142 4.03E-01 1.48E+00 1.78E-05 1.94E-143 La-143 3.88E-01 1.42E+00 2.19E-31 0.00E+00 Nb-95 4.33E-01 1.59E+00 1.07E+00 6.03E-01 Nb-95m 4.93E-03 1.81E-02 1.03E-02 3.92E-05 Nb-97 4.04E-01 1.48E+00 9.93E-07 4.77E-181 Nb-97m 3.81E-01 1.39E+00 0.00E+00 0.00E+00 Nd-147 1.65E-01 6.06E-01 3.92E-01 6.28E-02 Pm-147 5.18E-02 1.90E-01 1.31E-01 1.28E-01 Pm-148 4.13E-02 1.51E-01 9.17E-02 2.17E-03 Pm-148m 8.09E-03 2.96E-02 2.01E-02 1.23E-02 Pm-149 1.40E-01 5.12E-01 2.58E-01 2.92E-05 Pm-151 4.89E-02 1.79E-01 6.87E-02 2.89E-09 Pr-142 1.47E-02 5.40E-02 1.56E-02 1.73E-13 Pr-143 3.82E-01 1.40E+00 9.17E-01 2.08E-01 Pr-144 3.21E-01 1.18E+00 6.73E-26 0.00E+00 Sm-153 1.09E-01 4.01E-01 1.93E-01 5.72E-06 Tb-160 2.45E-04 8.98E-04 6.12E-04 4.64E-04 Y-90 2.52E-01 2.54E-01 1.35E-01 7.29E-05 Y-91 3.35E+00 3.38E+00 2.30E+00 1.63E+00 Y-91m 1.89E+00 1.91E+00 2.51E-09 3.69E-262 Y-92 3.44E+00 3.47E+00 2.17E-02 1.46E-61 Y-93 2.57E+00 2.60E+00 3.44E-01 6.27E-22 Y-94 4.04E+00 4.07E+00 1.87E-23 0.00E+00 Y-95 4.17E+00 4.20E+00 1.54E-41 0.00E+00 Zr-95 4.31E-01 1.58E+00 1.08E+00 7.86E-01 Zr-97 4.01E-01 1.47E+00 3.78E-01 1.52E-13 H-3 3.32E+00 3.32E+00 2.29E+00 2.28E+00 Rn-220 9.39E-10 3.44E-09 0.00E+00 0.00E+00 Total 3.25E+02 3.91E+02 1.05E+02 1.11E+01

    • NOTE: All noble gases are assumed to be released from solution immediately after entering the LRWS.

DSAR-11.1 Information Use Page 25 of 52 Radioactive Waste Disposal System Rev. 4 The operating plant anticipated annual quantities of liquid waste releases and the corresponding annual average concentrations in the discharge tunnel are given in Table 11.1-16 for those nuclides expected to have annual average concentrations greater than 1x10-20 Ci/cc. As illustrated by the table, it is expected that no single nuclide will exceed 1 percent of 10 CFR Part 20 limits on an annual average basis. Cumulative dose contributions from radioactive materials in liquid effluents released to unrestricted areas shall be determined on a quarterly basis in accordance with the ODCM. The total annual average concentration of liquid wastes discharged, excluding tritium, is not expected to exceed 8.2E-08 Ci/cc. The operating plant expected annual average concentration of tritium in the discharge tunnel was approximately 2.14 E-08 Ci/cc.

For the purposes of calculating the operating plant anticipated concentrations, an annual average discharge tunnel flow of 305,000 gpm was used. This average flow was obtained by assuming the use of two circulating water pumps and one raw water pump during six cold months of the year and use of three circulating water pumps and one raw water pump during the six warmer months. For Bounding worst case scenario of reduced circulating water (120,000 gpm) the expected annual average concentration of liquid wastes is still below the 10 CFR Part 20 limits.

Effluents shall be limited to ten times 10 CFR Part 20, Appendix B, Table 2, Column 2 concentrations at discharge.

Calculations have been made to determine the downstream concentration of radionuclides discharged in the circulating water discharge from the Fort Calhoun Station into the Missouri River.

These calculations were based on a model developed and experimentally verified by Yotsukura, Fischer and Sayre in:

"Measurements of Mixing Characteristics of the Missouri River between Sioux City, Iowa, and Plattsmouth, Nebraska, U. S.

Geological Survey Water Supply paper 1899-G, U. S.

Government Printing Office, Washington: 1970". The computer code described in this publication was obtained by OPPD and its applicability confirmed by comparison with experimental data contained in the paper for a center-of-stream source of dye and its dispersion in the river reach adjacent to the plant site.

The calculated maximum concentration of wastes is shown in Figure 11.1-1 as a function of distance. Conditions are shown for a maximum distance of 19.5 miles, which corresponds to the location of the municipal water intake for the city of Omaha.

DSAR-11.1 Information Use Page 26 of 52 Radioactive Waste Disposal System Rev. 4 The source is assumed to be a continuous release of material from the bank which is uniformly mixed with 5% of the total river discharge and the 5% stream tube has the same concentration from the point of injection to 200 feet downstream.

Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits NUCLIDE Total Activity Released Annually Ci Average Annual Concentration Ci/cc Bounding Case Annual Concentration Ci/cc 10 CFR 20 Limits Appendix B Table 2, Col 2 Ci/cc Fraction of Limits Annual Concentration Limit Kr-83m 3.42E-118 5.64E-127 2.01E-125 NA Kr-85 7.73E-01 1.27E-09 4.55E-08 NA Kr-85m 8.00E-48 1.32E-56 4.71E-55 NA Kr-87 1.57E-169 2.58E-178 9.23E-177 NA Kr-88 2.63E-75 4.33E-84 1.55E-82 NA Kr-89 0.00E+00 0.00E+00 0.00E+00 NA Kr-90 0.00E+00 0.00E+00 0.00E+00 NA Xe-131m 1.14E+00 1.88E-09 6.74E-08 NA Xe-133 8.57E+00 1.41E-08 5.05E-07 NA Xe-133m 3.31E-04 5.46E-13 1.95E-11 NA Xe-135 1.02E-22 1.68E-31 6.02E-30 NA Xe-135m 0.00E+00 0.00E+00 0.00E+00 NA Xe-137 0.00E+00 0.00E+00 0.00E+00 NA Xe-138 0.00E+00 0.00E+00 0.00E+00 NA Br-82 8.01E-09 1.32E-17 4.72E-16 4.00000000E-05 0.000000%

Br-83 2.38E-91 3.93E-100 1.40E-98 9.00000000E-04 0.000000%

Br-85 0.00E+00 0.00E+00 0.00E+00 NA I-129 1.35E-07 2.22E-16 7.93E-15 2.00000000E-07 0.000000%

I-130 2.38E-19 3.93E-28 1.40E-26 2.00000000E-05 0.000000%

I-131 1.31E+00 2.17E-09 7.74E-08 1.00000000E-06 0.216565%

I-132 6.96E-95 1.15E-103 4.10E-102 1.00000000E-04 0.000000%

I-133 2.82E-10 4.65E-19 1.66E-17 7.00000000E-06 0.000000%

I-134 5.44E-247 8.96E-256 3.20E-254 4.00000000E-04 0.000000%

I-135 7.30E-33 1.20E-41 4.30E-40 3.00000000E-05 0.000000%

I-136 0.00E+00 0.00E+00 0.00E+00 NA Cs-132 5.50E-06 9.07E-15 3.24E-13 4.00000000E-05 0.000000%

Cs-134 5.97E-01 9.84E-10 3.52E-08 9.00000000E-07 0.109352%

Cs-134m 4.76E-76 7.84E-85 2.80E-83 NA Cs-135m 6.93E-247 1.14E-255 4.08E-254 1.00000000E-03 0.000000%

Cs-136 3.95E-02 6.50E-11 2.32E-09 6.00000000E-06 0.001084%

Cs-137 4.60E-01 7.58E-10 2.71E-08 1.00000000E-06 0.075806%

Cs-138 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

DSAR-11.1 Information Use Page 27 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits NUCLIDE Total Activity Released Annually Ci Average Annual Concentration Ci/cc Bounding Case Annual Concentration Ci/cc 10 CFR 20 Limits Appendix B Table 2, Col 2 Ci/cc Fraction of Limits Annual Concentration Limit Cs-139 0.00E+00 0.00E+00 0.00E+00 NA Cs-140 0.00E+00 0.00E+00 0.00E+00 NA Rb-86 5.42E-03 8.93E-12 3.19E-10 7.00000000E-06 0.000128%

Rb-88 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

Rb-89 0.00E+00 0.00E+00 0.00E+00 9.00000000E-04 0.000000%

Rb-90 0.00E+00 0.00E+00 0.00E+00 NA Rb-90m 0.00E+00 0.00E+00 0.00E+00 NA Ag-110 0.00E+00 0.00E+00 0.00E+00 NA Ag-110m 1.38E-02 2.27E-11 8.11E-10 6.00000000E-06 0.000378%

Ag-111 1.35E-02 2.22E-11 7.94E-10 2.00000000E-05 0.000111%

Ag-112 9.80E-71 1.61E-79 5.77E-78 4.00000000E-05 0.000000%

As-76 4.26E-13 7.03E-22 2.51E-20 1.00000000E-05 0.000000%

Cd-115 2.64E-06 4.35E-15 1.55E-13 1.00000000E-05 0.000000%

Cd-115m 8.67E-04 1.43E-12 5.11E-11 4.00000000E-06 0.000036%

Ga-72 2.55E-20 4.20E-29 1.50E-27 2.00000000E-05 0.000000%

Ge-77 1.68E-22 2.77E-31 9.92E-30 1.00000000E-04 0.000000%

In-115m 1.48E-50 2.44E-59 8.73E-58 2.00000000E-04 0.000000%

Sb-122 1.60E-06 2.63E-15 9.40E-14 1.00000000E-05 0.000000%

Sb-124 1.94E-03 3.19E-12 1.14E-10 7.00000000E-06 0.000046%

Sb-125 3.10E-02 5.11E-11 1.83E-09 3.00000000E-05 0.000170%

Sb-127 1.41E-03 2.33E-12 8.33E-11 1.00000000E-05 0.000023%

Sb-129 6.51E-50 1.07E-58 3.83E-57 4.00000000E-05 0.000000%

Sb-130 0.00E+00 0.00E+00 0.00E+00 3.00000000E-04 0.000000%

Sb-130m 0.00E+00 0.00E+00 0.00E+00 NA Sb-131 0.00E+00 0.00E+00 0.00E+00 2.00000000E-04 0.000000%

Sb-132 0.00E+00 0.00E+00 0.00E+00 NA Sb-132m 0.00E+00 0.00E+00 0.00E+00 NA Sb-133 0.00E+00 0.00E+00 0.00E+00 NA Se-83 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

Sn-121 2.87E-10 4.73E-19 1.69E-17 8.00000000E-05 0.000000%

Sn-123 1.96E-03 3.23E-12 1.15E-10 9.00000000E-06 0.000036%

Sn-125 2.07E-03 3.42E-12 1.22E-10 6.00000000E-06 0.000057%

Sn-127 8.16E-105 1.34E-113 4.81E-112 9.00000000E-05 0.000000%

Te-127 2.06E-24 3.39E-33 1.21E-31 1.00000000E-04 0.000000%

Te-127m 4.24E-02 6.99E-11 2.50E-09 9.00000000E-06 0.000777%

Te-129 1.72E-187 2.84E-196 1.01E-194 4.00000000E-04 0.000000%

Te-129m 1.20E-01 1.97E-10 7.05E-09 7.00000000E-06 0.002817%

Te-131 0.00E+00 0.00E+00 0.00E+00 8.00000000E-05 0.000000%

DSAR-11.1 Information Use Page 28 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits NUCLIDE Total Activity Released Annually Ci Average Annual Concentration Ci/cc Bounding Case Annual Concentration Ci/cc 10 CFR 20 Limits Appendix B Table 2, Col 2 Ci/cc Fraction of Limits Annual Concentration Limit Te-131m 4.28E-08 7.05E-17 2.52E-15 8.00000000E-06 0.000000%

Te-132 8.70E-03 1.43E-11 5.12E-10 9.00000000E-06 0.000159%

Te-133 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

Te-133m 6.83E-235 1.13E-243 4.02E-242 9.00000000E-05 0.000000%

Te-134 0.00E+00 0.00E+00 0.00E+00 3.00000000E-04 0.000000%

Ba-137m 0.00E+00 0.00E+00 0.00E+00 NA Ba-139 1.55E-153 2.55E-162 9.11E-161 2.00000000E-04 0.000000%

Ba-140 1.30E+00 2.13E-09 7.63E-08 8.00000000E-06 0.026676%

Ba-142 0.00E+00 0.00E+00 0.00E+00 7.00000000E-04 0.000000%

Sr-89 2.56E+00 4.22E-09 1.51E-07 8.00000000E-06 0.052776%

Sr-90 3.60E-01 5.93E-10 2.12E-08 5.00000000E-07 0.118514%

Sr-91 8.29E-23 1.37E-31 4.88E-30 2.00000000E-05 0.000000%

Sr-92 5.49E-80 9.04E-89 3.23E-87 4.00000000E-05 0.000000%

Sr-93 0.00E+00 0.00E+00 0.00E+00 NA Sr-94 0.00E+00 0.00E+00 0.00E+00 NA Mo-99 9.49E-03 1.56E-11 5.59E-10 2.00000000E-05 0.000078%

Mo-101 0.00E+00 0.00E+00 0.00E+00 7.00000000E-04 0.000000%

Pd-109 2.09E-16 3.45E-25 1.23E-23 3.00000000E-05 0.000000%

Rh-103m 1.20E-231 1.98E-240 7.06E-239 6.00000000E-03 0.000000%

Rh-105 2.73E-06 4.50E-15 1.61E-13 5.00000000E-05 0.000000%

Rh-105m 0.00E+00 0.00E+00 0.00E+00 NA Rh-106 0.00E+00 0.00E+00 0.00E+00 NA Ru-103 3.36E+00 5.54E-09 1.98E-07 3.00000000E-05 0.018473%

Ru-106 1.95E+00 3.22E-09 1.15E-07 3.00000000E-06 0.107204%

Tc-99m 5.23E-36 8.62E-45 3.08E-43 NA Tc-101 0.00E+00 0.00E+00 0.00E+00 2.00000000E-03 0.000000%

Tc-104 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

Tc-105 0.00E+00 0.00E+00 0.00E+00 NA Ce-141 3.22E+00 5.30E-09 1.89E-07 3.00000000E-05 0.017661%

Ce-143 1.56E-06 2.57E-15 9.18E-14 2.00000000E-05 0.000000%

Ce-144 4.37E+00 7.21E-09 2.58E-07 3.00000000E-06 0.240264%

Np-239 1.11E-02 1.82E-11 6.52E-10 2.00000000E-05 0.000091%

Pu-238 1.22E-02 2.02E-11 7.21E-10 2.00000000E-08 0.100818%

Pu-239 1.57E-03 2.59E-12 9.27E-11 2.00000000E-08 0.012971%

Pu-240 2.06E-03 3.39E-12 1.21E-10 2.00000000E-08 0.016934%

Pu-241 5.28E-01 8.70E-10 3.11E-08 1.00000000E-06 0.086990%

Pu-242 8.73E-06 1.44E-14 5.14E-13 2.00000000E-08 0.000072%

Th-228 1.33E-08 2.20E-17 7.85E-16 2.00000000E-07 0.000000%

DSAR-11.1 Information Use Page 29 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits NUCLIDE Total Activity Released Annually Ci Average Annual Concentration Ci/cc Bounding Case Annual Concentration Ci/cc 10 CFR 20 Limits Appendix B Table 2, Col 2 Ci/cc Fraction of Limits Annual Concentration Limit Am-241 6.37E-04 1.05E-12 3.75E-11 2.00000000E-08 0.005245%

Cm-242 1.59E-01 2.61E-10 9.34E-09 7.00000000E-07 0.037332%

Cm-244 1.74E-02 2.86E-11 1.02E-09 3.00000000E-08 0.095298%

Eu-154 2.66E-02 4.38E-11 1.57E-09 7.00000000E-06 0.000626%

Eu-155 1.15E-02 1.89E-11 6.77E-10 5.00000000E-05 0.000038%

Eu-156 2.14E-01 3.52E-10 1.26E-08 8.00000000E-06 0.004400%

Eu-157 4.74E-16 7.80E-25 2.79E-23 3.00000000E-05 0.000000%

Eu-158 1.71E-285 2.82E-294 1.01E-292 3.00000000E-04 0.000000%

Eu-159 0.00E+00 0.00E+00 0.00E+00 NA Gd-159 4.52E-14 7.46E-23 2.67E-21 4.00000000E-05 0.000000%

Ho-166 2.44E-12 4.02E-21 1.44E-19 1.00000000E-05 0.000000%

La-140 2.82E-05 4.65E-14 1.66E-12 9.00000000E-06 0.000001%

La-141 3.18E-55 5.23E-64 1.87E-62 5.00000000E-05 0.000000%

La-142 1.13E-142 1.86E-151 6.67E-150 1.00000000E-04 0.000000%

La-143 0.00E+00 0.00E+00 0.00E+00 5.00000000E-04 0.000000%

Nb-95 3.51E+00 5.79E-09 2.07E-07 3.00000000E-05 0.019299%

Nb-95m 2.29E-04 3.77E-13 1.35E-11 3.00000000E-05 0.000001%

Nb-97 2.78E-180 4.59E-189 1.64E-187 3.00000000E-04 0.000000%

Nb-97m 0.00E+00 0.00E+00 0.00E+00 NA Nd-147 3.66E-01 6.03E-10 2.16E-08 2.00000000E-05 0.003016%

Pm-147 7.46E-01 1.23E-09 4.40E-08 7.00000000E-05 0.001757%

Pm-148 1.27E-02 2.09E-11 7.46E-10 7.00000000E-06 0.000298%

Pm-148m 7.19E-02 1.18E-10 4.24E-09 1.00000000E-05 0.001185%

Pm-149 1.70E-04 2.80E-13 1.00E-11 2.00000000E-05 0.000001%

Pm-151 1.68E-08 2.78E-17 9.93E-16 2.00000000E-05 0.000000%

Pr-142 1.01E-12 1.66E-21 5.93E-20 1.00000000E-05 0.000000%

Pr-143 1.22E+00 2.00E-09 7.16E-08 2.00000000E-05 0.010012%

Pr-144 0.00E+00 0.00E+00 0.00E+00 6.00000000E-04 0.000000%

Sm-153 3.34E-05 5.50E-14 1.97E-12 3.00000000E-05 0.000000%

Tb-160 2.70E-03 4.45E-12 1.59E-10 1.00000000E-05 0.000045%

Y-90 4.25E-04 7.00E-13 2.50E-11 7.00000000E-06 0.000010%

Y-91 9.51E+00 1.57E-08 5.60E-07 8.00000000E-06 0.195969%

Y-91m 2.15E-261 3.54E-270 1.27E-268 2.00000000E-03 0.000000%

Y-92 8.51E-61 1.40E-69 5.01E-68 4.00000000E-05 0.000000%

Y-93 3.66E-21 6.02E-30 2.15E-28 2.00000000E-05 0.000000%

Y-94 0.00E+00 0.00E+00 0.00E+00 4.00000000E-04 0.000000%

Y-95 0.00E+00 0.00E+00 0.00E+00 7.00000000E-04 0.000000%

Zr-95 4.58E+00 7.55E-09 2.70E-07 2.00000000E-05 0.037757%

DSAR-11.1 Information Use Page 30 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Anticipated Quantities and Concentrations of Principle Radionuclides in the Discharge Tunnel Including Hypothetical Bounding Case and Comparison to 10 CFR 20 Limits NUCLIDE Total Activity Released Annually Ci Average Annual Concentration Ci/cc Bounding Case Annual Concentration Ci/cc 10 CFR 20 Limits Appendix B Table 2, Col 2 Ci/cc Fraction of Limits Annual Concentration Limit Zr-97 8.88E-13 1.46E-21 5.23E-20 9.00000000E-06 0.000000%

H-3 1.33E+01 2.19E-08 7.82E-07 1.00000000E-03 0.002188%

Rn-220 0.00E+00 0.00E+00 0.00E+00 NA Total 6.46E+01 1.06E-07 3.80E-06 1.62E-02 Annual Average Concentration (excluded Tritium) = 8.2E-08 Ci/cc

DSAR-11.1 Information Use Page 31 of 52 Radioactive Waste Disposal System Rev. 4 11.1.2.8 Availability and Reliability The liquid waste system will function properly with wide variations in processed volume.

The liquid waste process equipment is dependent on the electrical systems, and on the demineralized water system. Collection of waste is chiefly by gravity and is therefore, almost wholly independent of auxiliary systems.

The liquid waste system has a duplicate sampling and analyzing capability. Liquid waste is analyzed at the waste hold-up tanks or at the Filtration/Ion exchange influent and then again at the monitor tanks, thus ensuring that effluent to the overboard header has always had two independent analyses. In addition, the radiation monitor at the overboard header automatically stops this flow if it exceeds a pre-determined concentration of radioactivity.

The transport pumping sets in the liquid waste system have redundancies, with one of the two pumps being a spare for the other.

Redundant volume is provided in the waste holdup tanks, spent regenerant tanks, and the hotel waste tanks; two tanks are furnished for spent regenerant and two for hotel wastes whereas three tanks are furnished for waste holdup. In the case of two tanks, the second is normally a complete spare of the first in volume capacity. In the case of three tanks, the capacity of 1-1/2 tanks is spare volume. The usual mode of operation is for one tank to be collecting while another tank is being discharged to treatment.

DSAR-11.1 Information Use Page 32 of 52 Radioactive Waste Disposal System Rev. 4 11.1.2.9 Operation The liquid waste processing system is operated to minimize the amount of radioactivity contained in liquid effluents from the plant.

A program of equipment operation and maintenance will be in effect to provide maximum system availability. Only under unusual circumstances of severe need would a system component be bypassed if it could, within detectable limits, significantly reduce the activity of the waste liquid. Waste liquids are segregated as to radioactivity level and point of origin. Liquid wastes are held for sufficient duration to allow decay of short-lived radioactive nuclides prior to processing and release.

Hotel waste tanks are normally diverted for processing if the activity level is above the limits established for release. All liquids are sampled and analyzed prior to release.

System flexibility ensures that proper treatment brings waste quantities and activities well within the limits of 10 CFR Part 20 and 40 CFR 190. In addition to this flexibility, it is possible to reprocess any volume of liquid if this need should occur.

The radiation monitors may be inoperable and liquid releases may continue provided the requirements of the ODCM are complied with. All liquid radioactive wastes originating within the containment, CARP and Radioactive Waste Processing Building are pumped to the auxiliary building. All radioactive liquids in the auxiliary building are collected in the RWDS. The radiation monitors utilized for monitoring RWDS are described in DSAR Section 11.2.3.

11.1.2.10 Tests and Inspections The purpose of the testing and inspection program was to ensure that the liquid waste system components meet design objectives and specifications.

All equipment in the system was subject to two types of test and inspections: manufacturer's shop tests and on-site tests.

DSAR-11.1 Information Use Page 33 of 52 Radioactive Waste Disposal System Rev. 4 Shop Tests All equipment was tested and inspected in the manufacturer's shop in accordance with the then applicable codes and standards.

In addition, some equipment was given performance type tests in the manufacturer's shop.

After preliminary operation to demonstrate the mechanical integrity and suitability of all components, a short term test program to demonstrate specific modes and methods of operation was undertaken. Chemical tests, such as boron concentration, and operating parameters, such as flow rates, were recorded during the test program. After the successful completion of the above tests, the equipment was partially disassembled and shipped to the plant site.

On-Site Tests On-site tests of the performance type to ensure that the overall liquid waste system functions in a safe and efficient manner were conducted prior to actual plant startup. Provisions were made to test the full operational sequence of the system. Pumps were started, valves operated, and instruments put into service. Flow paths, flow capacity, and mechanical operability were thoroughly checked. Pressure, temperature, flow and level indicating instruments were calibrated and checked for performance. All safety equipment, including alarms were thoroughly tested.

Special emphasis was placed on the proper functioning of the liquid waste instrumentation and controls on the waste control panel.

11.1.3 Gaseous Wastes 11.1.3.1 General The waste gas header is vented to the Auxiliary Building atmosphere. All waste gas release will be monitored in the Auxiliary Building stack (See DSAR section 11.2.3).

The calculated annual air dose at any location which could be occupied by individuals in unrestricted areas shall not exceed 10 millirads for gamma radiation, 20 millirads for beta radiation and 15 millirems to any organ for iodine-131, tritium, and other particulates with half-lives greater than eight days as required by 10 CFR Part 50, Appendix I.

DSAR-11.1 Information Use Page 34 of 52 Radioactive Waste Disposal System Rev. 4 The methods of dose calculation are defined in the Offsite Dose Calculation Manual.

There may be small amounts of radioactive gas in the Radioactive Waste Processing and CARP buildings. The amount of gas will be extremely low and releases will be measured and recorded.

The annual average dispersion factor (/Q) for gaseous releases used to determine exposures in the unrestricted area is calculated using data obtained from the meteorological program. This program is described in detail in DSAR Section 2.5. The annual average value of /Q is specified in the ODCM. A revision of this value, either due to subsequent data or revised criteria, would affect the gaseous release concentration in direct ratio to the change. The ODCM ensures that all releases are within applicable criteria.

11.1.3.2 Sources of Waste Gas The waste gas header is vented to the Auxiliary Building atmosphere. All waste gas release will be monitored in the Auxiliary Building stack (See DSAR section 11.2.3).

DSAR-11.1 Information Use Page 35 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Deleted

DSAR-11.1 Information Use Page 36 of 52 Radioactive Waste Disposal System Rev. 4 11.1.3.3 Processing of Waste Gases Waste gases from all of the sources mentioned above are collected in the vent header as shown in the process flow diagram P&ID 11405-M-98. The gas is then vented to the Auxiliary Building Ventilation system for discharge.

11.1.3.4 Deleted 11.1.3.5 Deleted 11.1.3.6 Deleted Table 11.1 Deleted 11.1.3.7 Design Evaluation Radiological Gases Released from Auxiliary Building It is expected that small amounts of radioactive gases, halogens and particulates may leak into the auxiliary building atmosphere.

Potential sources include the following:

a.

Venting of Spent Regenerant Tanks.

The vapor spaces of the Spent Regenerant Tanks (SRT) in the RWDS are vented to the Auxiliary Building Ventilating System.

The only liquids collected in the SRT are those which have been depressurized and aerated in the process of becoming a waste. WDS design in addition to reducing activity releases to the extent practicable, must also be inherently safe.

Liquids collected in the SRT along with their design activities are listed under "Auxiliary Systems Process Wastes", Section 11.1.2.1. Waste volumes for these sources as listed in Table 11.1-23 indicate that a total of 11,000 cu. ft. of liquid per cycle is discharged to the SRT.

Design activities for liquids entering the SRT are expected to be variable over a range of 10-7 to 6.0 Ci/cc as shown.

The maximum amount of gaseous activity that may be present in the Auxiliary Building Ventilating System from the SRT has been calculated and is summarized along with applicable design parameters in Table 11.1-23.

DSAR-11.1 Information Use Page 37 of 52 Radioactive Waste Disposal System Rev. 4 It is expected that small amounts of radioactive gases, halogens and particulates may be released to the CARP and Radioactive Waste Processing Building HVAC systems. The HVAC systems in these two buildings are designed to capture such releases and maintain personnel exposure ALARA. The sources for airborne radioactivity in the CARP and Radioactive Waste Processing Buildings were previously located in the existing Auxiliary Building.

Therefore they do not constitute a new source of airborne radioactive releases and the releases tabulated in Table 11.1-23 remain unchanged.

Potential sources include the following:

a.

Radioactive Waste Processing Building

1. DAW sorting.
2. DAW compaction
3. DAW Decontamination
4. Radwaste Filtration and Ion Exchange System
5. Radwaste Solidification System
b.

CARP Building

1. Laboratory

DSAR-11.1 Information Use Page 38 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Maximum Gaseous Release, Spent Regenerant Tanks Design Liquid volume cycle [1] to SRT = 11,000 cu. ft.

Maximum annual average activity, liquid mixture = 2.18 Ci/cc Fraction volatiles present in liquid [2] = 0.5 Fraction volatiles immediately released = 1.0 Auxiliary Building ventilation rate = 7.25x104 SCFM Maximum Average Activity [3]

Concentration in Aux. Bldg. Vent. Sys. = 3.15E-7 Ci/cc Maximum SRT release to Auxiliary Building Ventilation System is approximately 0.9 Ci/day of waste gases. The majority of the activity is from noble gases.

[1]

One cycle is equivalent to 530 full power days.

[2]

Estimate is conservative since liquid has been previously aerated.

[3] Volatile composition as shown in Table 11.1-21.

c.

Discussion of RWDS Vent Connections.

It is concluded that under design conditions for failed fuel the liquids contained in Spent Regenerant are not a significant source of gaseous activity release.

d.

Relief Valve Discharges.

The RWDS is designed, by making maximum use of connected tankage, to contain relief discharges with the system. Referring to P&ID 11405-M-98, the RWDS waste gas circuit flow diagram, the Vent Header is connected through unchecked piping to the vapor spaces of all three Waste Holdup Tanks. Locked open valves WD-441, 442 and 443 and the tank vent lines as shown in P&ID 11405-M-8 provide an interconnecting manifold between the vapor spaces of the three tanks.

DSAR-11.1 Information Use Page 39 of 52 Radioactive Waste Disposal System Rev. 4

e.

Total Releases from Auxiliary Building Of the sources discussed above, the major one is projected to be released from venting of the concentrate tanks. Total gaseous releases from the auxiliary building over a year's time have been assumed to be 150% of the releases from the concentrate tank vents, based on the total quantity of liquid wastes to be processed (see Table 11.1-2). It is further assumed that the decontamination factors given in item c above apply and that the HEPA filters in the auxiliary building discharge have a 90% efficiency for removal of particulates. The resulting releases are as given in Table 11.1-25.

Radioactive Gases Released from Containment Gases from Containment will be minimal following plant shutdown and no longer having Reactor Coolant.

Containment gas will be processed through normal Auxiliary Building ventilation. Table 11.1-25 will not be updated. New release data would be conservative.

Total Radioactive Gaseous Releases NOTE: Containment gas contributors have been removed from this section. Table 11.1-25 will not be updated. New release date would be conservative.

The total expected annual activity release to the atmosphere from the (1) waste gas system, (2) containment purges, (3) auxiliary building ventilation and (4) primary-to-secondary leakage and (5) Radioactive Waste Processing and CARP buildings are (accounted for in the Auxiliary Building Ventilation Release) listed in Table 11.1-25. Also given are the average concentration at the boundary of the unrestricted area. An average-annual dispersion factor of 5.0x10-6 sec/m3 has been used to determine the isotopic activities at the boundary (Amendment 113(11.4.12, 11.4.13)). The maximum whole body dose at the boundary of the restricted area, consistent with the average concentrations at the boundary in Table 11.1-25, is approximately 1.08 millirad/year, based on continuous occupancy.

DSAR-11.1 Information Use Page 40 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Kr-83m 7.65E-117 9.01E+00 6.910E+00 2.76E-01 1.62E+01 2.5685E-12 NA Kr-85 1.73E+01 7.92E-01 6.069E-01 6.58E+00 2.53E+01 4.0058E-12 NA Kr-85m 1.79E-46 1.91E+01 1.462E+01 1.43E+00 3.51E+01 5.5690E-12 NA Kr-87 3.50E-168 3.83E+01 2.937E+01 8.14E-01 6.85E+01 1.0862E-11 NA Kr-88 5.87E-74 5.35E+01 4.102E+01 2.54E+00 9.71E+01 1.5390E-11 NA Kr-89 0.00E+00 6.72E+01 5.150E+01 5.93E-02 1.19E+02 1.8827E-11 NA Kr-90 0.00E+00 7.23E+01 5.538E+01 1.08E-02 1.28E+02 2.0238E-11 NA Xe-131m 2.56E+01 6.68E+00 5.123E+00 2.63E+01 6.37E+01 1.0100E-11 2E-6 5.05E-06 Xe-133 1.92E+02 4.60E+02 3.527E+02 9.49E+02 1.95E+03 3.0968E-10 5E-7 0.0006194 Xe-133m 7.40E-03 4.47E+00 3.429E+00 3.93E+00 1.18E+01 1.8767E-12 6E-7 3.128E-06 Xe-135 2.28E-21 5.32E+01 4.076E+01 8.12E+00 1.02E+02 1.6180E-11 7E-8 0.0002311 Xe-135m 0.00E+00 2.97E+01 2.277E+01 1.26E-01 5.26E+01 8.3414E-12 4E-8 0.0002085 Xe-137 0.00E+00 1.30E+02 9.951E+01 1.38E-01 2.29E+02 3.6381E-11 NA Xe-138 0.00E+00 1.24E+02 9.485E+01 4.85E-01 2.19E+02 3.4733E-11 2E-8 0.0017367 Br-82 4.89E-09 3.06E-07 2.348E-07 1.81E-08 5.64E-07 8.9423E-20 5E-9 1.788E-11 Br-83 1.45E-91 1.29E-05 9.894E-06 5.17E-08 2.29E-05 3.6235E-18 9E-8 4.026E-11 Br-85 0.00E+00 2.72E-05 2.087E-05 2.17E-09 4.81E-05 7.6257E-18 NA I-129 8.22E-08 0.00E+00 2.870E-12 3.12E-12 8.22E-08 1.3029E-20 4E-11 3.257E-10 I-130 1.45E-19 2.26E-06 1.729E-06 4.66E-08 4.03E-06 6.3920E-19 3E-9 2.131E-10 I-131 8.02E-01 4.85E-04 3.717E-04 1.44E-04 8.03E-01 1.2729E-13 2E-10 0.0006364 I-132 4.24E-95 1.45E-04 1.112E-04 5.54E-07 2.57E-04 4.0734E-17 2E-8 2.037E-09 I-133 1.72E-10 2.05E-04 1.575E-04 7.14E-06 3.70E-04 5.8662E-17 1E-9 5.866E-08 I-134 3.32E-247 2.29E-04 1.759E-04 3.36E-07 4.06E-04 6.4324E-17 6E-8 1.072E-09 I-135 4.45E-33 1.95E-04 1.494E-04 2.14E-06 3.47E-04 5.4942E-17 6E-9 9.157E-09 I-136 0.00E+00 9.14E-05 7.006E-05 3.54E-09 1.61E-04 2.5600E-17 NA Cs-132 3.36E-06 3.79E-09 2.907E-09 9.45E-10 3.36E-06 5.3340E-19 6E-9 8.89E-11

DSAR-11.1 Information Use Page 41 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Cs-134 3.64E-01 1.71E-05 1.308E-05 1.40E-05 3.64E-01 5.7780E-14 2E-10 0.0002889 Cs-134m 2.90E-76 3.87E-06 2.963E-06 1.88E-08 6.85E-06 1.0855E-18 2E-7 5.428E-12 Cs-135m 4.23E-247 3.99E-06 3.056E-06 5.88E-09 7.05E-06 1.1175E-18 3E-7 3.725E-12 Cs-136 2.41E-02 5.32E-06 4.081E-06 2.23E-06 2.41E-02 3.8188E-15 9E-10 4.243E-06 Cs-137 2.81E-01 1.28E-05 9.820E-06 1.07E-05 2.81E-01 4.4505E-14 2E-10 0.0002225 Cs-138 0.00E+00 1.92E-04 1.472E-04 1.72E-07 3.39E-04 5.3814E-17 8E-8 6.727E-10 Cs-139 0.00E+00 1.80E-04 1.377E-04 4.64E-08 3.17E-04 5.0321E-17 NA Cs-140 0.00E+00 1.62E-04 1.239E-04 4.78E-09 2.86E-04 4.5277E-17 NA Rb-86 1.21E-02 1.68E-06 1.291E-06 8.46E-07 1.21E-02 1.9214E-15 1E-9 1.921E-06 Rb-88 0.00E+00 7.90E-04 6.056E-04 3.91E-07 1.40E-03 2.2133E-16 9E-8 2.459E-09 Rb-89 0.00E+00 1.04E-03 7.938E-04 4.38E-07 1.83E-03 2.9011E-16 2E-7 1.451E-09 Rb-90 0.00E+00 9.60E-04 7.360E-04 6.82E-08 1.70E-03 2.6894E-16 NA Rb-90m 0.00E+00 2.94E-04 2.255E-04 3.52E-08 5.20E-04 8.2387E-17 NA Ag-110 0.00E+00 1.66E-05 1.275E-05 1.90E-10 2.94E-05 4.6570E-18 NA Ag-110m 8.40E-03 4.16E-07 3.186E-07 3.32E-07 8.40E-03 1.3313E-15 1E-10 1.331E-05 Ag-111 8.22E-03 6.10E-06 4.677E-06 1.71E-06 8.23E-03 1.3055E-15 1E-9 1.305E-06 Ag-112 5.98E-71 2.80E-06 2.143E-06 1.47E-08 4.95E-06 7.8529E-19 1E-8 7.853E-11 As-76 2.60E-13 2.03E-09 1.554E-09 8.91E-11 3.67E-09 5.8199E-22 2E-9 2.91E-13 Cd-115 1.61E-06 8.29E-07 6.354E-07 7.40E-08 3.15E-06 4.9905E-19 2E-9 2.495E-10 Cd-115m 5.29E-04 3.84E-08 2.944E-08 2.56E-08 5.29E-04 8.3881E-17 1E-10 8.388E-07 Ga-72 1.56E-20 1.66E-09 1.269E-09 3.90E-11 2.96E-09 4.6983E-22 4E-9 1.175E-13 Ge-77 1.03E-22 7.03E-08 5.385E-08 1.33E-09 1.25E-07 1.9886E-20 8E-9 2.486E-12 In-115m 9.04E-51 8.29E-07 6.354E-07 6.21E-09 1.47E-06 2.3315E-19 6E-8 3.886E-12 Sb-122 9.74E-07 9.80E-08 7.509E-08 1.06E-08 1.16E-06 1.8351E-19 2E-9 9.175E-11 Sb-124 1.18E-03 7.61E-08 5.832E-08 5.36E-08 1.18E-03 1.8750E-16 3E-10 6.25E-07 Sb-125 1.89E-02 8.80E-07 6.745E-07 7.26E-07 1.89E-02 2.9997E-15 7E-10 4.285E-06

DSAR-11.1 Information Use Page 42 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Sb-127 8.63E-04 8.70E-06 6.671E-06 1.34E-06 8.79E-04 1.3944E-16 1E-9 1.394E-07 Sb-129 3.97E-50 3.21E-05 2.460E-05 2.36E-07 5.69E-05 9.0245E-18 1E-8 9.024E-10 Sb-130 0.00E+00 1.07E-05 8.180E-06 1.17E-08 1.89E-05 2.9907E-18 9E-8 3.323E-11 Sb-130m 0.00E+00 4.47E-05 3.429E-05 7.84E-09 7.90E-05 1.2529E-17 NA Sb-131 0.00E+00 7.88E-05 6.037E-05 5.04E-08 1.39E-04 2.2067E-17 6E-8 3.678E-10 Sb-132 0.00E+00 4.67E-05 3.578E-05 5.46E-09 8.25E-05 1.3073E-17 NA Sb-132m 0.00E+00 4.55E-05 3.484E-05 3.54E-09 8.03E-05 1.2732E-17 NA Sb-133 0.00E+00 6.66E-05 5.106E-05 4.63E-09 1.18E-04 1.8656E-17 NA Se-83 0.00E+00 6.00E-06 4.602E-06 3.73E-09 1.06E-05 1.6823E-18 2E-7 8.411E-12 Sn-121 1.75E-10 8.12E-07 6.224E-07 3.67E-08 1.47E-06 2.3325E-19 2E-8 1.166E-11 Sn-123 1.19E-03 6.39E-08 4.901E-08 4.92E-08 1.19E-03 1.8946E-16 2E-10 9.473E-07 Sn-125 1.27E-03 4.98E-07 3.820E-07 1.70E-07 1.27E-03 2.0085E-16 5E-10 4.017E-07 Sn-127 4.98E-105 3.50E-06 2.683E-06 1.23E-08 6.20E-06 9.8235E-19 3E-8 3.275E-11 Te-127 1.26E-24 8.58E-06 6.578E-06 1.34E-07 1.53E-05 2.4246E-18 2E-8 1.212E-10 Te-127m 2.59E-02 1.43E-06 1.094E-06 1.08E-06 2.59E-02 4.1043E-15 4E-10 1.026E-05 Te-129 1.05E-187 3.06E-05 2.348E-05 5.93E-08 5.42E-05 8.5880E-18 9E-8 9.542E-11 Te-129m 7.30E-02 6.17E-06 4.733E-06 3.84E-06 7.30E-02 1.1576E-14 3E-10 3.859E-05 Te-131 0.00E+00 8.36E-05 6.410E-05 5.82E-08 1.48E-04 2.3430E-17 2E-8 1.172E-09 Te-131m 2.61E-08 1.99E-05 1.524E-05 9.96E-07 3.61E-05 5.7314E-18 1E-9 5.731E-09 Te-132 5.31E-03 1.43E-04 1.094E-04 1.86E-05 5.58E-03 8.8425E-16 9E-10 9.825E-07 Te-133 0.00E+00 1.13E-04 8.627E-05 3.92E-08 1.99E-04 3.1529E-17 8E-8 3.941E-10 Te-133m 4.17E-235 9.26E-05 7.099E-05 1.43E-07 1.64E-04 2.5963E-17 2E-8 1.298E-09 Te-134 0.00E+00 1.87E-04 1.433E-04 2.18E-07 3.30E-04 5.2391E-17 7E-8 7.484E-10 Ba-137m 0.00E+00 1.22E-05 9.335E-06 8.65E-10 2.15E-05 3.4111E-18 NA Ba-139 9.44E-154 1.84E-04 1.407E-04 4.32E-07 3.25E-04 5.1472E-17 4E-8 1.287E-09 Ba-140 7.90E-01 1.84E-04 1.409E-04 7.55E-05 7.91E-01 1.2534E-13 2E-9 6.267E-05

DSAR-11.1 Information Use Page 43 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Ba-142 0.00E+00 1.60E-04 1.224E-04 4.71E-08 2.82E-04 4.4739E-17 2E-7 2.237E-10 Sr-89 1.56E+00 1.07E-04 8.236E-05 7.34E-05 1.56E+00 2.4789E-13 2E-10 0.0012394 Sr-90 2.19E-01 1.00E-05 7.677E-06 8.34E-06 2.19E-01 3.4789E-14 6E-12 0.0057982 Sr-91 5.06E-23 1.33E-04 1.021E-04 2.12E-06 2.37E-04 3.7646E-17 5E-9 7.529E-09 Sr-92 3.35E-80 1.40E-04 1.070E-04 6.32E-07 2.47E-04 3.9180E-17 9E-9 4.353E-09 Sr-93 0.00E+00 1.55E-04 1.189E-04 3.20E-08 2.74E-04 4.3443E-17 NA Sr-94 0.00E+00 1.53E-04 1.176E-04 5.35E-09 2.71E-04 4.2962E-17 NA Mo-99 2.12E-02 1.87E-03 1.433E-03 2.06E-04 2.47E-02 3.9212E-15 2E-9 1.961E-06 Mo-101 0.00E+00 1.69E-03 1.295E-03 6.87E-07 2.99E-03 4.7329E-16 2E-7 2.366E-09 Pd-109 1.28E-16 3.82E-05 2.925E-05 8.73E-07 6.83E-05 1.0828E-17 6E-9 1.805E-09 Rh-103m 7.31E-232 1.58E-04 1.215E-04 2.48E-07 2.80E-04 4.4430E-17 2E-6 2.221E-11 Rh-105 1.66E-06 1.02E-04 7.807E-05 6.02E-06 1.88E-04 2.9745E-17 8E-9 3.718E-09 Rh-105m 0.00E+00 3.11E-05 2.385E-05 6.50E-10 5.50E-05 8.7148E-18 NA Rh-106 0.00E+00 6.30E-05 4.826E-05 8.70E-10 1.11E-04 1.7634E-17 NA Ru-103 2.05E+00 1.59E-04 1.217E-04 1.03E-04 2.05E+00 3.2538E-13 9E-10 0.0003615 Ru-106 1.19E+00 5.74E-05 4.397E-05 4.65E-05 1.19E+00 1.8882E-13 2E-11 0.0094409 Tc-99m 3.19E-36 1.65E-04 1.267E-04 1.66E-06 2.94E-04 4.6560E-17 NA Tc-101 0.00E+00 1.69E-04 1.295E-04 6.68E-08 2.99E-04 4.7329E-17 5E-7 9.466E-11 Tc-104 0.00E+00 1.31E-04 1.002E-04 6.66E-08 2.31E-04 3.6640E-17 1E-7 3.664E-10 Tc-105 0.00E+00 1.08E-04 8.310E-05 2.29E-08 1.92E-04 3.0369E-17 NA Ce-141 1.96E+00 1.69E-04 1.299E-04 1.04E-04 1.96E+00 3.1109E-13 8E-10 0.0003889 Ce-143 9.51E-07 1.60E-04 1.224E-04 8.80E-06 2.92E-04 4.6277E-17 2E-9 2.314E-08 Ce-144 2.67E+00 1.31E-04 1.002E-04 1.05E-04 2.67E+00 4.2317E-13 2E-11 0.0211587 Np-239 6.76E-03 2.10E-03 1.610E-03 1.98E-04 1.07E-02 1.6909E-15 3E-9 5.636E-07 Pu-238 7.47E-03 3.40E-07 2.609E-07 2.84E-07 7.47E-03 1.1838E-15 2E-14 0.0591892 Pu-239 9.60E-04 4.38E-08 3.354E-08 3.65E-08 9.61E-04 1.5230E-16 2E-14 0.007615

DSAR-11.1 Information Use Page 44 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Pu-240 1.25E-03 5.71E-08 4.379E-08 4.76E-08 1.25E-03 1.9883E-16 2E-14 0.0099417 Pu-241 3.22E-01 1.47E-05 1.129E-05 1.23E-05 3.22E-01 5.1071E-14 8E-13 0.0638391 Pu-242 5.33E-06 2.43E-10 1.860E-10 2.02E-10 5.33E-06 8.4442E-19 2E-14 4.222E-05 Th-228 8.13E-09 0.00E+00 2.925E-13 3.13E-13 8.13E-09 1.2894E-21 2E-14 6.447E-08 Am-241 3.88E-04 1.77E-08 1.357E-08 1.47E-08 3.88E-04 6.1589E-17 2E-14 0.0030794 Cm-242 9.68E-02 5.01E-06 3.838E-06 3.92E-06 9.68E-02 1.5342E-14 4E-13 0.0383554 Cm-244 1.06E-02 4.84E-07 3.708E-07 4.02E-07 1.06E-02 1.6785E-15 3E-14 0.055949 Eu-154 1.62E-02 7.44E-07 5.702E-07 6.18E-07 1.62E-02 2.5720E-15 3E-11 8.573E-05 Eu-155 7.01E-03 3.23E-07 2.478E-07 2.68E-07 7.01E-03 1.1117E-15 2E-10 5.559E-06 Eu-156 1.30E-01 2.33E-05 1.789E-05 1.06E-05 1.30E-01 2.0673E-14 6E-10 3.446E-05 Eu-157 2.89E-16 2.48E-06 1.901E-06 6.29E-08 4.44E-06 7.0442E-19 7E-9 1.006E-10 Eu-158 1.04E-285 8.70E-07 6.671E-07 1.11E-09 1.54E-06 2.4392E-19 8E-8 3.049E-12 Eu-159 0.00E+00 4.40E-07 3.373E-07 2.22E-10 7.77E-07 1.2327E-19 NA Gd-159 2.76E-14 5.96E-07 4.565E-07 1.85E-08 1.07E-06 1.6973E-19 8E-9 2.122E-11 Ho-166 1.49E-12 8.26E-09 6.335E-09 3.70E-10 1.50E-08 2.3737E-21 2E-9 1.187E-12 La-140 1.72E-05 1.88E-04 1.444E-04 1.27E-05 3.63E-04 5.7505E-17 2E-9 2.875E-08 La-141 1.94E-55 1.68E-04 1.288E-04 1.10E-06 2.98E-04 4.7220E-17 1E-8 4.722E-09 La-142 6.90E-143 1.65E-04 1.263E-04 4.18E-07 2.92E-04 4.6227E-17 3E-8 1.541E-09 La-143 0.00E+00 1.58E-04 1.215E-04 6.24E-08 2.80E-04 4.4401E-17 1E-7 4.44E-10 Nb-95 2.14E+00 1.77E-04 1.357E-04 1.11E-04 2.14E+00 3.3994E-13 2E-9 0.00017 Nb-95m 1.40E-04 2.02E-06 1.545E-06 2.91E-07 1.43E-04 2.2731E-17 3E-9 7.577E-09 Nb-97 1.70E-180 1.65E-04 1.265E-04 3.31E-07 2.92E-04 4.6281E-17 1E-7 4.628E-10 Nb-97m 0.00E+00 1.56E-04 1.193E-04 4.33E-09 2.75E-04 4.3574E-17 NA Nd-147 2.23E-01 6.76E-05 5.180E-05 2.53E-05 2.23E-01 3.5431E-14 1E-9 3.543E-05 Pm-147 4.55E-01 2.12E-05 1.625E-05 1.75E-05 4.55E-01 7.2197E-14 2E-10 0.000361 Pm-148 7.72E-03 1.69E-05 1.295E-05 3.56E-06 7.76E-03 1.2299E-15 7E-10 1.757E-06

DSAR-11.1 Information Use Page 45 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Annual Releases of Radioactive Gases and Particulates NUCLIDE Annual Release Gas 12 month basis Ci SG BLOWDOWN Secondary Activity 45 day release Ci GASEOUS RELEASE Auxiliary Building Annually Ci GASEOUS RELEASE Containment Building Annually Ci TOTAL CURIES Released Annually Ci CONCENTRATION Site Boundry Ci/cc 10 CFR 20 LIMITS Appendix B

Table 2 Column 1 Ci/cc FRACTION OF 10 CFR 20 Limits Pm-148m 4.39E-02 3.31E-06 2.534E-06 2.16E-06 4.39E-02 6.9554E-15 4E-10 1.739E-05 Pm-149 1.04E-04 5.71E-05 4.379E-05 5.06E-06 2.10E-04 3.3248E-17 2E-9 1.662E-08 Pm-151 1.03E-08 2.00E-05 1.532E-05 9.48E-07 3.63E-05 5.7484E-18 4E-9 1.437E-09 Pr-142 6.14E-13 6.03E-06 4.621E-06 1.93E-07 1.08E-05 1.7190E-18 3E-9 5.73E-10 Pr-143 7.41E-01 1.56E-04 1.198E-04 6.66E-05 7.42E-01 1.1760E-13 9E-10 0.0001307 Pr-144 0.00E+00 1.31E-04 1.006E-04 6.31E-08 2.32E-04 3.6775E-17 2E-7 1.839E-10 Sm-153 2.04E-05 4.47E-05 3.429E-05 3.46E-06 1.03E-04 1.6303E-17 4E-9 4.076E-09 Tb-160 1.65E-03 1.00E-07 7.677E-08 7.25E-08 1.65E-03 2.6149E-16 3E-10 8.716E-07 Y-90 9.42E-04 1.03E-04 7.901E-05 1.10E-05 1.13E-03 1.7995E-16 9E-10 1.999E-07 Y-91 2.11E+01 1.37E-03 1.051E-03 9.62E-04 2.11E+01 3.3451E-12 2E-10 0.0167255 Y-91m 4.76E-261 7.73E-04 5.925E-04 1.07E-06 1.37E-03 2.1668E-16 2E-7 1.083E-09 Y-92 1.89E-60 1.41E-03 1.077E-03 8.31E-06 2.49E-03 3.9484E-16 1E-8 3.948E-08 Y-93 8.10E-21 1.05E-03 8.068E-04 1.78E-05 1.88E-03 2.9762E-16 3E-9 9.921E-08 Y-94 0.00E+00 1.65E-03 1.265E-03 8.59E-07 2.92E-03 4.6243E-16 1E-7 4.624E-09 Y-95 0.00E+00 1.70E-03 1.306E-03 4.98E-07 3.01E-03 4.7735E-16 2E-7 2.387E-09 Zr-95 2.80E+00 1.76E-04 1.351E-04 1.25E-04 2.80E+00 4.4335E-13 4E-10 0.0011084 Zr-97 5.42E-13 1.64E-04 1.256E-04 4.62E-06 2.94E-04 4.6622E-17 2E-9 2.331E-08 H-3 2.97E+02 1.36E-03 1.042E-03 1.13E-03 2.97E+02 4.7075E-11 1E-7 0.0004708 Rn-220 0.00E+00 0.00E+00 2.944E-13 9.91E-18 2.94E-13 4.6680E-26 3E-11 1.556E-15 Total 5.72E+02 1.07E+03 8.19E+02 1.00E+03 3.46E+03 5.48E-10

DSAR-11.1 Information Use Page 46 of 52 Radioactive Waste Disposal System Rev. 4 11.1.3.8 Availability and Reliability The waste gas header is vented to the Auxiliary Building atmosphere. All waste gas release will be monitored in the Auxiliary Building stack (See DSAR section 11.2.3). The general Waste Gas Disposal system description below pertains to how the system was operated prior to being permanently defueled.

Radioactive gaseous effluents can be released from the plant without being so indicated on an installed radiation monitor if the requirements of the ODCM are complied with. The monitoring system is described in DSAR Section 11.2.3.

The radiation monitor at the discharge duct provides a check on radioactivity, and if the activity exceeds a predetermined limit, it provides an alarm.

Interlocks and other design features have been incorporated in the RWDS to preclude in so far as practical any gaseous release except under fully controlled conditions. Typical among these features are:

a.

Maximum use of available RWDS tankage by an unchecked, interconnected vapor space arrangement as previously described in part "e" of this section (Relief Valve Discharges).

b.

Vents and drains arrangements as described in part "a" of this section (Venting of Spent Regenerant Tanks) provides three separate liquid drain circuits and a closed vent circuit arranged to retain activity within the auxiliary building.

c.

Interlocks on RWDS components provide equipment shutdown in the event of malfunction.

DSAR-11.1 Information Use Page 47 of 52 Radioactive Waste Disposal System Rev. 4 11.1.3.9 Operation The operation of the gaseous waste system is such that values for radioactive effluent release are maintained as low as reasonably achievable (ALARA). The normal operation for waste gas systems is the release of waste gas to the Auxiliary Building ventilation header. The release rates for radioactive materials, other than noble gases, in gaseous effluents is controlled such that concentrations of radionuclides do not exceed ten times 10 CFR 20 Appendix B, Table 2, Column 1 limits. For noble gases, the concentration shall be limited to five times 10 CFR 20, Appendix B, Table 2, Column 1 limits. Concentrations shall be calculated based upon the annual average Chi/Q(11.4.12, 11.4.13).

Cumulative dose contributions must be determined in accordance with the Offsite Dose Calculation manual (ODCM) on a quarterly basis. Prior to discharge of radioactive materials in gaseous effluents, the equipment used in processing gaseous effluents is operated in accordance with the requirements of the ODCM. The setpoints for the effluent radiation monitors are calculated in accordance with the ODCM. The requirements for equipment functionality are defined in the ODCM. The requirements for sampling and activity analyses for radioactive gaseous waste and the requirements for verification of equipment operability are given in the ODCM.

11.1.3.10 Tests and Inspections Shop Tests Some equipment was tested and inspected in the manufacturer's shop in accordance with then applicable codes and standards. In addition, some equipment was given performance type tests in the manufacturer's shop.

DSAR-11.1 Information Use Page 48 of 52 Radioactive Waste Disposal System Rev. 4 On-Site Tests These tests were primarily of the performance type and were designed to ensure that the overall gaseous waste system functions in a safe and efficient manner and were conducted prior to actual plant startup.

Provision was made to test the full operational sequence of the system. Flow paths, flow capacity, and mechanical operability were thoroughly checked. Pressure, temperature, flow and level indicating instruments were calibrated and checked for performance. All safety equipment, including alarms, were thoroughly tested.

Tracer gases, such as P-10 (10% Methane - 90% Argon), Helium and Sulfur Hexafluoride can be used as a leak detection medium in conjunction with a suitable detector, to locate leaks in the waste gas system outside containment. P-10 is non-flammable, non-toxic and does not become radioactive unless subjected to a neutron radiation field.

11.1.4 Solid Wastes 11.1.4.1 General The general types of radioactive solid wastes produced at the station include process resins, used waste and process filters, dewatered ion exchange and filtration media, and miscellaneous solid wastes.

Spent resin from the filtration/ion exchange system is sluiced to a high integrity container which is deterred and eventually shipped for disposal. Used filters are placed in a shielded container, stored in the cask decontamination area and eventually shipped from the plant. Miscellaneous solid wastes, such as equipment parts and laboratory glassware, are stored prior to off-site shipment.

The flow diagram, P&ID 11405-M-8, shows the process portion of the solid waste disposal system.

11.1.4.2 Sources of Solid Waste

a.

Radioactive liquid waste is processed either through a filtration/ion exchange system with the processed water being directed to the monitor tanks.

DSAR-11.1 Information Use Page 49 of 52 Radioactive Waste Disposal System Rev. 4

b.

Process wastes containing spent resins are obtained from the spent fuel storage pool demineralizer.

The resins from other sources and their sluice water are collected in the spent resin storage tank. The contents of this tank are mixed and solids are kept in suspension by nitrogen gas sparging. The contents of the tank are forced by pressurized demineralized water into a shielded resin cask after which the contents are dewatered and shipped from the plant. At this point it is considered to be a solid waste.

c.

Used filter baskets originate from other, the waste filters and the spent fuel pool cooling system filter. Solids removed from the liquid are retained on the filter elements which form the basket.

d.

Miscellaneous solid waste consist of contaminated articles such as equipment parts, laboratory glassware, clothing, gloves, cleaning tools, rags, towels, and plastic covers originating in the controlled access areas of the plant.

Table 11.1-26 shows the anticipated waste volumes on cycle basis.

Note: Since Fort Calhoun Station is permanently shutdown and defueled, the radioactive waste generation and removal needs are reduced. As a result, radioactive waste estimates for a running plant are considered to bound the needs of the shutdown plant.

DSAR-11.1 Information Use Page 50 of 52 Radioactive Waste Disposal System Rev. 4 Table 11.1 Solid Waste Volumes Volume Sources (ft3/cycle)

Basis Spent Resins Spent Fuel Pool Demineralizer 10 1/5 vessel/cycle Filter Elements Waste Filters 5

each filter assembly Spent Fuel Pool Filter 5

per cycle Miscellaneous Solids 2,000 Assumed value for low activity solids.

Total 2,020

  • With an 18 month cycle operation, the amount of solid waste volumes generated is assumed to remain the same based on the number shutdowns and waste inventory.

11.1.4.3 System Components The major components of the solid wastes system of the RWDS are as follows; the referenced tables summarize pertinent data:

a.

Spent resin storage tank (see Table 11.1-12);

b.

Spent resin pump (see Table 11.1-13);

c.

Mobile Radwaste Processing System/Filtration/Ion Exchanger (FIX)

DSAR-11.1 Information Use Page 51 of 52 Radioactive Waste Disposal System Rev. 4 11.1.4.4 System Operation Radioactive Liquid and Spent Resins The following operation is followed for the processing of liquid and resin.

a.

If the filtration/ion exchange system is in operation, the radioactive liquid is transferred from the waste holdup tanks using the waste holdup transfer pumps. The water that has been processed is directed to the monitor tanks to be analyzed and discharged to the Missouri River through the overboard discharge piping. Depleted filtration ion exchange media is sluiced to a high integrity container and then dewatered using vendor supplied system prior to being shipped offsite for disposal.

b.

The resin is flushed from the spent resin storage tank by demineralized water to a shielded resin cask with liner located in the Radioactive Waste Processing Building through shielded piping. The resin is then dewatered/solidified. The liner with resin is placed in the cask which is shipped offsite.

Miscellaneous Solid Waste Non-compactable waste are placed in large steel boxes for disposal. The activity of this material is normally low and special shielding is not necessary.

11.1.4.5 Design Evaluation The spent resin storage tank has a volume of 400 cu. ft. and is designed to hold at least two to three years production of spent resins. Excess transport water used to convey resins to the tank is removed by pumping from a screened lateral connection in the tank. Transport water returns to the spent regenerant tanks.

Nitrogen is admitted through the bottom lateral at a sufficient rate to mix the resin slurry.

Spent resin can have high activity; therefore the resin casks are equipped with internal shields designed to reduce the external dose rate to a level permitting in-plant handling.

DSAR-11.1 Information Use Page 52 of 52 Radioactive Waste Disposal System Rev. 4 11.1.4.6 Availability and Reliability The solid waste system is normally operated on a batch basis, and is available to perform abnormal or emergency functions.

The solid waste system is dependent on the operation of the filtration/ion exchange system. These systems are also dependent on the electrical systems, the demineralized water system, the plant compressed air system, and nitrogen gas.

The Process Control Program (PCP) is used to verify satisfactory solidification of waste prior to shipment offsite.

The Radioactive Waste Processing Building is sized to accumulate a number of containers (e.g., liners, drums, high integrity containers) to permit scheduling of off-site shipments.

11.1.4.7 Tests and Inspections All equipment in the solid waste system was subject to both shop and on-site tests.

Shop Tests All equipment was tested and inspected in the manufacturer's shop in accordance with the then applicable codes.

In addition, some equipment was given performance type tests in the manufacturer's shop.

On-Site Tests These tests were primarily of the performance type and were designed to ensure that the overall solid waste system functions in a safe and efficient manner. These tests were conducted prior to actual plant startup.

Provision was made to test the full operational sequence of the system. Pumps were started, valves operated, instruments put into service.

Inspection of Containers in Storage Provisions are included for inspection of containers while in storage by using TV cameras or boroscope for high radiation level conditions, and by direct observation when radiation levels are low.