Proposed Tech Specs,Allowing Removal of High Pressure Scram Function When Reactor Head Removed or Unbolted
ML20155B245
Person / Time
Site: Oyster Creek
Issue date: 09/28/1988
From:
GENERAL PUBLIC UTILITIES CORP.
To:
Shared Package
ML20155B229 List:
References
NUDOCS 8810060246
Download: ML20155B245 (2)


Text

.. . - - - . - . .-. .

~

S '

- h, TABLE 3.1.1 (CONTD) ,

o g -

) ;;; ogg. These functions are not required to be operable when secondary contairweent is not required to be maintained or

  • when the conditions of Section 3.5.b.1.a. b, c, and d are met, and reactor water level is closely monitored and logged hourly. The Sta'dbyn Gas Treatment System wil: be mar.ually initiated if reactor water level drops to the .;

low level trip set point.

hh. The high flow trip function for "B" Isolation Condenser is bypassed upon initiation o the alternate shutdown panel. This prevents a spurious trip of the isolation condenser in the event of fire induced circuit damage.

11. Instrument shall be operable during main condenser air ejector operation except that a channel may be taken out-of-service for the purpose of a check, calibration, test, or maintenance without declaring it to be inoperable.

aj. With no channel OPERABLE, main condenser offgas may be released to the environment for as 1. ,9 as 72 hoces provided the stack radioactive noble gis monitor is OPERABLE. Otherwise, te in at least SHilTDOWN CONDITICN within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

kk. Reserved.

w 11. This function not required to be operable with tna reactor vessel head removed or unbolted.

~

~

b Y

E i

ao i

" BS10060246 08092829

. PDR ADOCK 050

, p _

-S C

O This note is applicable only during the Cycle 10M outage.

~

e

.,, ._, ._, . - - - _ - = - - _ . ._ _ - - . . -. . -- - - - - , .

/ . .

en

  • 24 TABLE 3.1.1 PROTECTIVE INSTRUMENTATION REQUIREMENTS .

~

~~

Reactor Modes Min. No. of 21in. No. of .

in which Function Operable or Instrument .

"; ~

Must Be Operable Operating Channels Per - H

^ [ tripped] Operable Action Function Trip Setting Shutdown Refuel Startup Run Trip Systems Trip Systems Required

1. Manual Scram X X X X 2 1 Insert control rods
2. High Reactor ** K(s) X(11) 2 2 X l Pressure
3. High Drywell 3.5 pstg X(u) X(u) X 2 2 u, Pressure

~

f. 4. Low Reactor X X X 2 2 Water Level
5. a. High Water 29 gal. X(a) X(z) X(z) 2 2 Level in Scram Discharge Volume North Side 3-

@ b. High Water 29 gal. X(a) X(z) X(z) 2 2 St Level in Scram

@ Discharge Volume South Side E

. 6. Low Condenser 23" hg. X(b) X(b) X 2 2 j Vacuum no j -

7. High Padiation 10 x normal X(s) X X 2 2-

! i in Main Steam hackground

~

! Line Tunnel

! 23

~

i I EI I~

0 l$

i

! [1

~

l