FUNCTION LIMITING SAFETY SYSTEM SETTINGS B.

Neutron Flux, The Rod Block setting shall be Control Rod Block FRP S s [(0.90 x 10) W + 53.1] [MFLPD]

with a maximum setpoint of 108% for 6

core flow equal to 61 x 10 lb/hr and greater.

j The definitions of S, W, FRP and MFLPD used above for the APRM scram trip apply.

The ratio of FRP to MFLPD shall be set equal to 1.0 unless the actual operating value is less than 1.0, in which case the actual operating value will be used.

This adjustment may be accomplished by increasing the APRM gain and thus reducing the flow referenced APRM rod block curve by the reciprocal of the APRM gain change.

C.

Reactor High, 11060 psig Pressure, Scram D.

Reactor High Pressure.

2 @ s 1085 psig Relief Valves Initiation 3 @ s 1105 psig E.

Reactor High Pressure, 11060 psig with time delay Isolation Condenser 53 seconds initiation F.

Reactor High Pressure, 4 @ 1212 psig 12 psi Safety Valve Initiation 5 @ 1221 psig 12 psi G.

Low Pressure Main Steam 2825 psig (initiated in IRM Line, MSly Closure range 10)

H.

Main Steam Line Isolation

$10% Valve Closure from Valve Closure, Scram full open I.

Reactor Low Water Level, 211'5" above the top of the Scram active fuel as indicated under normal operating conditions J.

Reactor Low-Low Water 27'2" above the top of the Level, Main Steam Line active fuel as indicated under Isolation Valve Closure normal operating conditions OYSTER CREEK 2.3-2 Amendment No. 164, 9406220152 940615 PDR ADOCK 05000219 P