Category:LICENSEE EVENT REPORT (SEE ALSO AO RO)
MONTHYEAR05000333/LER-1993-0171993-08-30030 August 1993 LER 93-017-00:on 930729,declared APRM Downscale,Companion IRM Upscale Inoperable Due to Misinterpretation of Sr. Initiated Plant Shutdown & Declared Unusual Event Until Trip Was corrected.W/930830 Ltr 05000333/LER-1993-0161993-08-23023 August 1993 LER 93-016-00:on 930722,missed Source Check of Radwaste Discharge Monitor Prior to Discharge of Waste Sample Tank a Due to Failure to Follow Procedures.Performed Source Check & Counseled Involved indiviuals.W/930823 Ltr 05000333/LER-1991-0321993-05-0101 May 1993 LER 91-032-01:on 911226,determined That During Postulated CR Fire,Existing Design of Circulating Water Sys Intake Structure Deicing Heaters Outside Design Basis.Caused by Omission of Heaters in Analyses.Fsar revised.W/930501 Ltr 05000333/LER-1983-060, Updated LER 83-060/03X-1:on 831130,incorrect Motor Actuator Installed on RHR Suppression Pool Outboard Isolation Valve During Maint Activities.Cause Not Stated.Replacement Actuator Installed on 840119.W/840203 Ltr1984-02-0303 February 1984 Updated LER 83-060/03X-1:on 831130,incorrect Motor Actuator Installed on RHR Suppression Pool Outboard Isolation Valve During Maint Activities.Cause Not Stated.Replacement Actuator Installed on 840119.W/840203 Ltr ML20071G2541978-12-20020 December 1978 /03L-0 on 781122:during Shutdown & Surveillance Test,A Number of Battery Cells Were Found W/Specific Gravity &/Or Individual Cell Voltage Variations(High or Low) Greater than Allowed by Test Acceptance Criteria ML20071G1391978-12-18018 December 1978 /04X-1 on 781006:3rd Quarter Release of Halogens & Particulates Greater than Tech Specs.Caused by Steam Leaks & Fuel Pin Clad Performance ML20071F9161978-11-28028 November 1978 /03L-0 on 781101:during Refueling & Maint Shutdown It Was Found That Surveillance Test Had Not Been Performed for Combustion Ionization Products Smoke Detectors Installed in Diesel Fire Pump Room on 780310,due to Oversight ML20071F8651978-11-17017 November 1978 /04L-0 on 781024:excess Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Detected.Caused by Unsound Sampling & Method of Determining Concentrations & Dissolved Solids ML20148F2461978-11-0101 November 1978 /04T-0 on 781018:Environ Radiological Monitoring Sample of Periphyton Samples Pci/Gm(Wet)Does Not Meet Subj Facil Tech Spec Append B,Paragraph 5.6.2.6 ML20071F4241978-10-0303 October 1978 /04L-0 on 780914:An Apparent Excessive Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Was Detected While Performing Aug 78 24-hour Complete Sample Analysis 1993-08-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARJAFP-99-0277, Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With1999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With ML20217A9931999-09-30030 September 1999 NRC Regulatory Assessment & Oversight Pilot Program, Performance Indicator Data JAFP-99-0261, Monthly Operating Rept for Aug 1999 for Jafnpp.With1999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Jafnpp.With JAFP-99-0236, Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with1999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with ML20216D9541999-07-28028 July 1999 Safety Evaluation Authorizing Proposed Alternatives for Second 10-year Interval Pursuant to 10CFR50.55a(a)(3)(ii) ML20196H8621999-06-30030 June 1999 NRC Regulatory Assessment & Oversight Pilot Program, Performance Indicator Data, June 1999 Rept JAFP-99-0211, Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0175, Annual Summary of Changes,Tests & Experiments for 1997/1998. with1999-06-0202 June 1999 Annual Summary of Changes,Tests & Experiments for 1997/1998. with JAFP-99-0181, Monthly Operating Rept for May 1999 for Jafnpp.With1999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Jafnpp.With JAFP-99-0166, Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With1999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With JAFP-99-0142, Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0092, Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With ML20207E9311999-02-26026 February 1999 Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced ML20202J0891999-02-0303 February 1999 Safety Evaluation Accepting Rev 2 of Third Interval Inservice Testing Program for Pumps & Valves for James a FitzPatrick Nuclear Power Plant ML20199M0891999-01-22022 January 1999 Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc JAFP-99-0011, Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With ML20198F9991998-12-0404 December 1998 Assessment of Licensing Basis for Use of Containment Overpressure Credit for Net Positive Suction Head Analyses Power Authority of State of New York,James a Fitzpatrick Nuclear Power Plant ML20196J3501998-12-0404 December 1998 SER Accepting License Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves JAFP-98-0396, Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with1998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with ML20196F9251998-11-25025 November 1998 Safety Evaluation Re Thrid 10-year Interval Inservice Insp Program Relief Requests for Plant ML20195J7521998-11-18018 November 1998 Rev 7 to Jaf Colr ML20195K4211998-11-17017 November 1998 Safety Evaluation Authorizing Proposed Alternative in Relief Request VRR-05 Per 10CFR50.55a(a)(3)(i) & PRR-01,PRR-02R1, PRR-03,PRR-04,VRR-02,VRR-03 & VRR-04 Per 10CFR50.55a(a)(3)(ii) ML20195E1051998-11-13013 November 1998 Safety Evaluation Accepting Licensee Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power Operated Gate Valves, Issued 950817 ML20197G6221998-11-0606 November 1998 Non-proprietary Rev 7 to HI-971661, Licensing Rept for Reracking of Ja FitzPatrick Sfp ML20155H5321998-11-0303 November 1998 Safety Evaluation Authorizing Alternative to ASME Code Requirements for CRD Bolting ML20155H5801998-11-0303 November 1998 Safety Evaluation Authorizing Postponement of Beginning of Augmented Exam Requirements of 10CFR50.55a(g)(6)(ii)(A)(2) Re ASME Code,Section XI JAFP-98-0360, Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With ML20155C2821998-10-30030 October 1998 Non-proprietary Rev 0 to GENE-187-30-1598 Np, CRD Bolting Flaw Evaluation for Ja FitzPatrick Nuclear Power Plant ML20154L6591998-10-14014 October 1998 Safety Evaluation Accepting Licensee Proposed Alternative to Snubber Visual Inservice Exam Intervals & Sampling Rates Requirements Contained in ASME Code,Section Xi,Subsection Iwf,Article IWF-5000 JAFP-98-0322, Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With1998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With ML20153D2591998-09-21021 September 1998 SER Accepting Proposed Alternative Testing of Containment Following ECCS Suction Strainer Replacement ML20153B5611998-09-0101 September 1998 Rev 1 to JAF-SE-98-013, RHR & Core Spray Suppression Pool Suction Strainer Replacement ML20151X6891998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Ja FitzPatrick Nuclear Power Plant ML20237E8361998-08-25025 August 1998 Rev 6 to Colr ML20237E9471998-08-0808 August 1998 Rev 6 to Colr JAFP-98-0264, Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant1998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant ML20236X5881998-07-29029 July 1998 Safety Evaluation Supporting Amend 245 to License DPR-59 ML20236V8181998-07-29029 July 1998 Safety Evaluation Accepting Request for Relief from Implementation of Requirements of 10CFR50.55a Related to Containment Repair & Replacement Activities for James a FitzPatrick Nuclear Power Plant ML20153B5781998-07-28028 July 1998 Rev 0 to JAF-SE-98-025, HPCI & RCIC Suppression Pool Suction Strainer Replacement ML20236X3831998-07-14014 July 1998 Rev 2 to JAF-RPT-MULTI-02671, Summary of Detailed Evaluation for NRC Generic Ltr 96-06 ML20154L9201998-07-10010 July 1998 SER Accepting Rev to Reactor Vessel Surveillance Capsule Withdrawal Schedule for James a Fitzpatrick Nuclear Power Plant JAFP-98-0222, Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant1998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0193, Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant1998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant ML20248F3531998-05-21021 May 1998 Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being Adopted JAFP-98-0168, Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant1998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0128, Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant1998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant ML20217A4631998-03-23023 March 1998 Safety Evaluation Accepting Use of Three Heats/Lots of Hot Rolled XM-19 Matl in Core Shroud Repair Assemblies Re Licenses DPR-16 & DPR-59,respectively JAFP-98-0091, Monthly Operating Rept for Feb 1998 for JAFNPP1998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for JAFNPP ML20202G9081998-02-0606 February 1998 Safety Evaluation Re Amend to License DPR-59 to Revise TS Tables 3.2-2 & 4.2-2 JAFP-98-0058, Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant1998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant 1999-09-30
[Table view] |
Text
___ .._ . _ __ __ _. . . . . _ .
LICENSEE EVENT REPORT CONTROL BLOCK: l 1
l l l l l lh 6
(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) l011l8 9lN l Yl Jl Al Fl 1lgl5 l 0 l -l 0 l 0 lLICENSE 14 0
0 l 0NUMBER l - 10 l 0 l 0 l@l 25 426 l 1 LICENSE l 1 l 1TYPE l 1Jol@l67 CAT l l@
68 7 LICENSEE CODE 1 CON'T 101il 3gylL)@l0l5 l0 l0 l0l3]3l3@l168l0 l69 l l 8EVENT l 7DATE ] 8 ]@l 1 ] 1 ] REPORT 74 75 0 l I DATE l 7 l 880l@
7 8 60 61 DOCKET NUMBER EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h ]
Please See Attachment l j IO I2 J l I
101311 l
10141I i
10151 l I
10161l l
l0 l7] l I
I O 18 I I 80 7 8 9 DE CODE S BC E COMPONENT CODE SueCODE S E 1019I 7 8 9 IZ II l@ L_J@ LJ@ 12IzI 10 11 12 13 I I I 21@ W @ W @
18 19 20 SEQUENTI AL OCCURRENCE REPORT REVtSION E REPORT NO. CODE TYPE NO.
LE R RO
@ ,ag l 7VENTl8 l YE8AR l 0l 8l 7l 26 y
27 10 14 l 28 29 lTl 30 l-l 31 l 0]
32
,21 22 23 24 HOURS 22 SB IT FO SUPPLIE M ANUF ACTUR E R AKE AC O ON PL NT MET B ..
l33X lgl34Zl@ l2l@ l36Z l@ l0 l0 l0 l0 l 31 lY 41 l@ l42N]@ lZ 43 l@ l44 Zl 919l 9l@ 47 3b 40 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 Please See Attachment ;
,,,gj I
11 Iii l ,
l li 121 I l
11 13] I I
11 14.1 1 80 7 8 9 STA S % POWER OTHE R ST ATUS 015 O RY DISCOVERY DESCRIPTION 32 Ii l5 l ]g l0 l0 l0 lgl NA l l B j@l Environmental Monitoring Program l ACitVtTY CO TENT
- RELEASED OF RE LE ASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE NA l l NA l l1168 l9 l Z l @ J@l 7 10 11 44 45 B0 l PERSONNEL EXPOSURES NUMBE R TYPE DE SCRIPTION l i l 7 l l 0 l 0 ] 0 l@W@l NA l' ,
PERSONNELINJU IES NuM.E R oESCRiPnO~@
NA l li lR 8I 91010101@l 7 11 12 80 LOSS OF OR DAMAGE TO FACILtTY i
TYPE DESCRIPTION '
1 9 [Z_jhl NA 80 l
7 8 9 10
""'"* NRC USE ONLY ,
i issue l 2 ] O I [g]@Ot5CRiFnON@
l NA l lllllIlllllll!
7 8 9 10 68 69 80 3 7M1()7 E OF PREPARER _ PHONE:
315-342-3840
_{
~ ~ ~ . _ . - - _ - _ - ~ _ . , . - _ _ _ . _ . _ _ _ _ _ _ _
+-
ATTACHMENT TO LER-78-087/04T-0 Page 1 of 1 The following Environmental Radiological Monitoring sample is an anamalous measurement based on criteria outlined in the James A. FitzPatrick Nuclear Power Plant Technical Specifications, Appendix B, Paragraph 5.6.2.b:
Periphyton Samples pCi/gm (Wet) l Sample Location
- 1) Off-site 8/23/78 0.0059 + 0.0035
~~
Oswego Harbor
- 2) On-Site 8/23/78 0.10 + 0.01 NMPP
- 3) On- Site 8/23/78 0.03 + 0.0057 JAF
- See Technical Specifications, Appendix B, for location details.
The activity level of co-60 in sample number 2 is greater than ten times the control station sample (number 1 above) for the same sample period.
The total liquid release of Co-60 for the period of January 1,1978 to August 23, 1978 was 1.55E-2 Ci. An integrated release of this quantity should not produce any detectable environmental impact, and is well within the discharge limits re-quired by Technical Specifications, Appendix B.
An examination and analysis of similar sample activity data (December 1974 to present) shows a decreasing trend of sample activity in the periphyton samples taken in the vicinity of Nine Mile Point.
It should be noted that detection of a small quantity of Co-60 in the off-site (control) sample indicates the presence of Co-60 in Lake Ontario periphyton.
The control location for periphyton is the Oswego Harbor and based on the meteorology hydrology of the area should not be impacted by plant operation.
Similar events were reported in LER-78-068/04T-0, 78-072/04T-0, and 78-077/
04T-0.
--. - - , ,