Forwards Press Release 84-36 Re NRC Proposed Fine Against Util for 30 Alleged Violations.Util Ordered to Hire Consultant Firm to Evaluate Organization
ML20140H763
Person / Time
Site: Nine Mile Point, 05000000
Issue date: 03/21/1984
From: Kammerer C
NRC OFFICE OF CONGRESSIONAL AFFAIRS (OCA)
To: Damato A, Horton F, Markey E, Moynihan D, Ottinger R, Simpson A, Udall M
HOUSE OF REP., HOUSE OF REP., ENERGY & COMMERCE, SENATE
Shared Package
ML20140C961 List: ... further results
References
FOIA-85-478 NUDOCS 8510230102
Download: ML20140H763 (2)


Text

~.

~

E j'

March 21, 1984 b}jY{Y go s

f The Honorable Richard L. Ottinger, Chairman Subcommittee on Energy Co~nservation and Power Committee on Energy and Commerce United States House of Representatives Ifashingtnn, D.C.

20515

Dear Mr. Chairman:

Enclosed for your information is an announcement that the staff of the Nuclear Regulatory Col.1 mission (NRC) has cited the Niagara -

Mohawk Power Corporation of Syracuse, New York for alleged violations at Nine Mile Point Units 1 and 2.

It is planned.to nail this information to the' news media today, March 21, 1984.

Sincerely, Carlton Kanmerer, Director Office of Congressional. Affairs

Enclosure:

As stated cc:

Rep. Carlos Moorhead IDENTICAL LETTER SENT T0:

Sen. Alan Simpson / cc: Sen. Gary Hart Rep. Morris Udall / cc: Rep. Manuel Lu]an Rep. Edward Markey / cc: Rep. Ron Marlenee Sen. Daniel Moynihan Sen. Alfonse D'Amato Rep. Frank Horton 8510230102 851004 PDR FDIA JACOBS85-478 PM PRA 84-36 5%

0A

.......,g,,,,,,,

H~*

.E.M.ar........

emp 3/21/84 s:c rotu ais ne ao,sacu e2d*

OFFICIAL RECORD _ COPY

  • *om '*-32"2'

h f' "%,

UNITED STATES

! Tw I,,:

NUCLEAR REGULATORY COMMISSION N

ff Office of Public Affairs

%.?;;/

Washington, D.C. 20556 NRC 84-36 FOR IFFEDIATE RELEASE Tel.

301/d92-7715 (Wednesday, March 21,1924)

NRC STAFF CITES NIAGARA M0 HAWK; PROPOSES $180,000 FINE AND ORDERS COMPANY TO HIRE CONSULTANT TO EVALUATE CORPORATE ORGANIZATION The staff of the Nuclear Regulatory Comission has cited the Niagara Mohwak Power Corporation of Syracuse, New York, for 30 alleged violations of NRC requirements at the company's Nine Mile Point Nuclear Station, Units 1 and 2, near Oswego, New York.

The NRC staff proposes a fine of $100,000 for.the alleoed violations at Unit 2, and $80,000 for the alleged violations that occurred at Unit 1.

The NRC staff has ordered Niagara Mohawk to hire an independent management consultant to evaluate the company's organization, including the delegation of responsibilities, management control systems, communication system and management practices at the Unit 1 site and at the Niagara Mohawk corporate offices.

The NRC staff has also issued an order directing the company.to perform a review of the deficiencies that were identified by the NRC at Nine Mile Point Unit 2, which is still under construction.

The order states in part, "further information is necessary concerning the licensee's ability to manage construction and to determine the adequacy of the construction work completed to date."

The Unit 1 order is effective immediately. The Unit 2 order becomes effective upon the company's consent or the expiration of the hearing request period.

The company may request a hearing on either one or both of the orders within 30 days.

The 28 alleged violations at Nine Mile Point Unit 2 were identified during an NRC Construction Appraisal Team (CAT) inspection conducted between November 7 and December 9, 1983.

The alleged violations of NRC requirements identified at Nine Mile Point Unit 2 include:

--two instances of failing to institute measures to assure design ml.

--five instances of failing to properly control activities that might have affected the quality of construction at Nine Mile Point Unit 2.

--three instances of failing to establish measures to control the issuance of documents' used in constructing the facility.

--two instances of failing to establish measures to assure that materials, equipment and services used in building the facility conform to procurement documents.

--four instances of failing to adequately establish an inspection program to verify construction was done in conformance with documented instructions, procedures, and drawings.

--seven instances of failing to establish measures to assure that conditions adverse to quality construction were identified and corrected.

--three instances of failing to maintain sufficient quality control records.

The NRC staff proposes a fine of $100,000 for these alleged violations.

The two alleged violations at Nine Mile Point Unit I were identified during. regular NRC inspections. The NRC staff proposes a fine of $80,000 for these.

The first violation involved failure to maintain the integrity of the primary containment of the Unit I reactor from June 29 to October 17, 1983, while the reactor was at power. An isolation valve on a connection used for testing water level in the reactor suppression pool was open during plant operations when it was required to be closed. The suppression pool is designed 'to keep pressure in the primary containment from becoming excessive during a loss of coolant accident.

There was no release of radiation as a result of this alleged violation.

The second violation at Nine Mile Point Unit 1. involved failure to test, for a ten-year-period, the closure times of two reactor coolant system isolation valves. Technical specifications for operating the facility require that these valves should be tested at least once per operating cycle to ensure i

they close within specified time requirements.

Between 1973 and 1983, a period of time covering five operating cycles, the valve closure times were allegedly not tested.

In a' letter irforming the company of these actions, Richard C. DeYoung, Director of the NRC's Office of Inspection and Enforcement, requested that the company meet with him within 30 days "to explain the cause of the lack of control of licensed activities and to discuss those actions that you have taken or plan to take in response to the enclosed Orders that will provide continuing assurance that the NRC licensed activities at the Nine Mile Point facility are conducted in compliance with the Consnission's regulations for protection of the public health and safety."

The company has 30 days to pay the fine or to request in writing that part or all of it be withdrawn. The State of New York has been informed of this proposed enforcement action.

..