U-600487 L30- 86(03-18)-L 1A.120 4

i Attachment to U-600487 t

Clinton Power Station Inservice Inspection - Pump and Valve Testing Program (Revision 1) 1 2'

4 (Revised pages only) i j

i i

j 1

i i

i i-8603200037 860318 PDR ADOCK 05000461 1

i G

PDR,

4 I.

INTRODUCTION 4

. This program describes how safety-related pumps and valves will be tested to satisfy the requirements of the ASME Boiler and Pressure Vessel Code Section XI, Rules for the Inservice Inspection of Nuclear Power Plant Components, 1980 Edition, Winter 1981 Addenda.

The requirements of this edition and addenda will be used during the first 10 year inspection interval or until a later edition is selected to be used.

Later editions must be endorsed in 10CFR50.55a or approved by the appropriate enforcement and regulatory agencies prior to their use.

II.

PUMP TESTING A.

Scope The requirements of this program shall be applied to Class 1,2, and 3 pumps which are required to perform a specific function in shutting down the reactor or in mitigating the consequences of an accident and are provided with an emergency power source.

The pumps which are included in this program are listed in Table 1, Pumps Requiring Inservice Testing.

TABLE #1 Pumps Requiring Inservice Testing l

Equipment Number Equipment Name 4

1C41-C001A Standby Liquid Control (SLC) Pump A l

1C41-C001B Standby Liquid Control Pump B 1D00lPA Diesel Oil Transfer Pump A 1D00lPB Diesel Oil Transfer Pump B 1D00lPC Diesel Oil Transfer Pump C lE12-C002A Residual Heat Removal Pump A lE12-C002B Residual Heat Removal Pump B lE12-C002C Residual Heat Removal Pump C lE12-C003 Water Leg Pump lE21-C001 Low Pressure Core Spray Pump 1E21-C002 Water Leg Pump lE22-C001 High Pressure Core Spray Pump 1E22-C003 Water Leg Pump lE51-C001 Reactor Core Isolation Cooling (RCIC)

Pump lE51-C003 Water Leg Pump ISX0lPA Shutdown Service Water Pump A 1SX01PB Shutdown Service Water Pump B ISX0lPC Shutdown Service Water Pump C i

0VC08PA Control Room HVAC Chilled Water Pump A Rev 1 OVC08PB Control Room HVAC Chilled Water Pump B Reviulon 1 1

i LJE51 - - -_- -,--..~ -,

B.

Frequency of Testing Inservice tests of pumps shall be performed every 3 months during normal plant operations.

This frequency shall be maintained during extended cold shutdowns and refueling outages whenever possible.

If this frequency can not be maintained during these shutdown periods, the pump (s) shall be tested within 1 week of the plant being returned to normal operating conditions.

C.

Inservice Test Quantities The following test parameters shall be observed or measured during inservice testing of pumps, unless relief has been requested from the testing requirements (See Appendix A, Pump Testing Relief Requests).

1.

Speed (RCIC pump only, all other pumps are constant speed type).

2.

Inlet pressure (measured prior to pump startup and during testing).

3.

Differential pressure.

4.

Flow rate.

I 5.

Vibration amplitude.

6.

Proper lubrication level for those pumps not lubricated Rev 1 by the fluid being pumped or having grease lubricated bearings.

Relief from measuring bearing temperature has been requested for all pumps (except RCIC).

The technical justification for this request is in Appendix A.

D.

Reference Values 1.

Pump testing baseline reference values shall be established prior to fuel load or at the first operational surveillance test after it has been determined that the reference values represent acceptable pump operation.

2.

After a pump has been replaced, a new set of reference values shall be established using the results of the first inservice test run after the pump is returned to service.

Revision 1 LJE51 ;

VALVE TESTING LEGEhT

.T.ype B

-Butterfly Valve C

-Check Valve CV

-Control Valve EFC -Excess Flow Check Valve EX

-Explosive Valve G

-Gate. Valve GL

-Globe Valve NC

-Non-Slam Check Valve P

-Plug Valve' R

-Relief Valve SR

-Safety Relief Valve VR

-Vacuum Relief Valve MFC -Manual Flow Contrcl GSC -Discharge Stop Check Actuator AO

-Air Operated HO

-Hydraulic Operated M

-Manually Operated MO

-Motor Operated SO

-Solenoid Operated Rev 1l SC

-Self-Contained Normal Position / Test Position 0

-Open C

-Closed LO

-Locked Open Test Method 1.

Valve shall be exercised to the position required to fulfill its function.

2.

The stroke time of the valve shall be measured.

3.

Valve seat leakage test.

4.

Twenty percent (20%) of explosive charges shall be removed, fired, and replaced every two (2) years.

5.

Bench testing with suitable hydraulic or pneumatic equipment.

LJE51 Revision 1

Test Method (Cont'd) 6.

Valves with remote position indicators shall be observed.at least Rav 1 once every 2 years to verify that valve operation is accurately indicated.

7.

Loss of power test.

1 Test During 1.

Power Operations 1

2.

Startup 3.

Hot Shutdown 4.

Cold Shutdown 5.

Refueling j

Notes 1

]

1.

Test position is for exercising and stroke timing only.

i 2.

Valves will be leak rate tested during cold shutdown periods or refueling outages.

l 3.

Testing may be performed by outside contractor.

1

)

A 4

j i

i i

e LJE51 Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1071/2 1B21-F001 CL 2

1 A

MO C

D-4 3

4,5 C

M05-1071/2 1B21-F002 CL 2

1 A

MO C

E-4 3

4,5 0

M05-1004 See Relief 1B21-F010A NC 18 1

A/C C

C-7 1,3 5

Request 001 0

M05-1004 See Relief IB21-F010B NC 18 1

A/C C

A-7 1,3 5

Request 001 0

M05-1002/1 1B21-F016 G

3 1

A MO C

B-1 1,2,3 1-5 0

M05-1002/1 1B21-F019 G

3 1

A M0 C

B-1 1,2,3 1-5 0

M05-1002/1 See Relief IB21-F022A GL 24 1

A A0 C

C-2 1,2,3,7 5

Request 053 0

M05-1002/1 See Relief IB21-F022B GL 24 1

A A0 C

F-2 1,2,3,7 5

Request 053 0

M05-1002/1 See Relief IB21-F022C GL 24 1

A A0 C

A-2 1,2,3,7 5

Request 053 0

M05-1002/1 See Relief IB21-F022D CL 24 1

A AO C

D-2 1,2,3,7 5

Request 053

.l 0

See Relief IB21-F024A C

i 3

C C

M10-1002/5 1

5 Request 042 0

See Relief IB21-F024B C

i 3

C C

M10-1002/5 1

5 Request 042 i

O See Relief 1B21-F024C C

i 3

C C

M10-1002/5 1

5 Request 042 0

See Relief IB21-F024D C

i 3

C C

M10-1002/5 1

5 Request 042 0

M05-1002/2 See Relief 1B21-F028A GL 24 1

A A0 C

C-5 1,2,3,7 5

Request 053 0

M05-1002/2 See Relief IB21-F028B GL 24 1

A A0 C

E-5 1,2,3,7 5

Request 053 0

M05-1002/2 See Relief j

1B21-F028C GL 24 1

A A0 C

B-5 1,2,3,7 5

Request 053 0

M05-1002/2 See Relief IB21-F028D GL 24 1

A A0 C

E-5 1,2,3,7 5

Request 053 0

See Relief IB21-F029A C

i 3

C C

M10-1002/5 1

5 Request 042 0

See Relief 1B21-F029B C

1 3

C C

M10-1002/5 1

5 Request 042 LJE51A Revision 1 i

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS O

See Relief IB21-F029C C

i 3

C C

M10-1002/5 1

5 Request 042 0

See Relief IB21-F029D C

i 3

C C

M10-1002/5 1

5 Request 042 0

M05-1004 See Relief IB21-F032A NC 20 1

A/C A0 C

C-6 1,3,7 5

Request 001 0

M05-1004 See Relief 1B21-F032B NC 20 1

A/C A0 C

A-6 1,3,7 5

Request 001 l

C See Relief IB21-F036A C

1 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036F C

1 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036C C

i 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036J C

1 3

C 0,C M10-1002/2 1

5 Request 042 i

C See Relief IB21-F036L C

i 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036M C

i 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036N C

i 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief 1B21-F036P C

1 3

C 0,C M10-1002/2 1

5 Request 042 C

See Relief IB21-F036R C

i 3

C 0,C M10-1002/2 1

5 Request 042 C

M05-1002/1 See Relief IB21-F037A VR 10 3

C 0

C-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037B VR 10 3

C 0

E-6 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F037C VR 10 3

C 0

A-7 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037D VR 10 3

C 0

D-7 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037E VR 10 3

C 0

E-4 1

5 Request 003 C

M05-1002/1 See Relief 0

A-5 1

5 Request 003 IB21-F037F VR 10 3

C C

M05-1002/1 See Relief IB21-F037G VR 10 3

C 0

A-4 1

5 Request 003 LJE51A Revision 1 1

i T

POSITION VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1002/1 See Relief IB21-F037H VR 10 3

C 0

C-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037J VR 10 3

C 0

E-7 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037K VR 10 3

C 0

A-5 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F037L VR 10 3

C 0

D-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037M VR 10 3

C 0

E-3 1

5 Request 003 C

M05-1002/1 See Relief IB21-F0'7N VR 10 3

C 0

E-5 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F037P VR 10 3

C 0

A-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037R VR 10 3

C 0

D-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F037S VR 10 3

C 0

A-3 1

5 Request 003 C

See Relief IB21-F039B C

}

3 C

0 M10-1002/1 1

5 Request 042 C

See Relief 1B21-F039C C

i 3

C 0

M10-1002/1 1

5 Request 042 C

See Relief IB21-F039D C

i 3

C 0

M10-1002/1 1

5 Request 042 j

C See Relief 1B21-F039E C

i 3

C 0

M10-1002/1 1

5 Request 042 I

C See Relief IB21-F039H C

i 3

C 0

M10-1002/1 1

5 Request 042 C

See Relief 1B21-F039K C

i 3

C 0

M10-1002/1 1

5 Request 042 C

See Relief 1B21-F039S C

}

3,__

C 0

M10-1002/1 1

5 Request 042 l

C M05-1071/2 See Relief 1B21-F040 VR 2

3 C

0 D-3 1

5 Request 003 i

C M05-1002/1 IB21-F041A SR 8x10 1

C A0 C

C-6 5

4,5 See Note 3 C

M05-1002/1 IB21-F041B SR 8x10 1

C A0 C

F-7 5

4,5 See Note 3 C

M05-1002/1 IB21-F041C SR 8x10 1

C A0 C

B-8 5

4,5 See Note 3 LJE51A Revision 1 1

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1002/1 1B21-F041D SR 8x10 1

C A0 C

D-8 5

4,5 See Note 3 C

M05-1002/1 1B21-F041F SR 8x10 1

C A0 C

F-5 5

4,5 See Note 3 C

M05-1002/1 l

SR 8x10 1

C A0 C

B-6 5

4,5 See Note 3 l

1B21-F041G i

C M05-1002/1 1B21-F041L SR 8x10 1

C A0 C

B-4 5

4,5 See Note 3 C

M05-1002/1 IB21-F047A SR 8x10 1

C A0 C

C-6 5

4,5 See Note 3 C

M05-1002/1 IB21-F047B SR 8x10 1

C AO C

F-8 5

4,5 See Note 3 C

M05-1002/1 i

IB21-F047C SR 8x10 1

C A0 C

B-5 5

4,5 See Note 3 C

M05-1002/1 1B21-F047D SR 8x10 1

C A0 C

D-7 5

4,5 See Note 3 t

I C

M05-1002/1

[

1B21-F047F SR 8x10 1

C A0 C

F-4 5

4,5 See Note 3 f

j C

M05-1002/1 I

}

IB21-F051B SR 8x10 1

C A0 C

F-6 5

4,5 See Note 3 C

M05-1002/1 l

1B21-F051C SR 8x10 1

C A0 C

B-7 5

4,5 See Note 3 C

M05-1002/1

^

1B21-F051D SR 8x10 1

C A0 C

D-6 5

4,5 See Note 3 j

C M05-1002/1 l

1B21-F051G SR 8x10 1

C AO C

B-4 5

4,5

-See Note 3 2

0 M05-1004 See Relief 1

1B21-F065A G

20 2

B MO C

C-5 1,2 5

Request 004

}

O M05-1004 See Relief j

1B21-F065B G

20 2

B MO C

A-5 1,2 5

Request 004 j

0,C M05-1002/2 j

1B21-F067A GL 1) 1 A

M0 C

C-6 1,2,3 1-5 i

0,C M05-1002/2 I

I 1B21-F067B GL li 1

A M0 C

E-6 1,2,3 1-5 0,C M05-1002/2 1B21-F067C GL li 1

A MO C

A-6 1,2,3 1-5 I

0,C M05-1002/2 1B21-F067D GL 1) 1 A

MO C

D-6 1,2,3 1-5 C

M05-1002/1 See Relief l

1B21-F078A VR 10 3

C 0

C-6 1

5 Request 003 LJE51A Revision 1 1

POSITION VALVE NORM P&ID TEST TEST y

NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1002/1 See Relief IB21-F078B VR 10 3

C 0

E-6 1

5 Request 003

~

C M05-1002/1 See Relief 1B21-F078C VR 10 3

C 0

A-7 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F078D VR 10 3

C 0

D-7 1

_5_

Request 003 C

M05-1002/1 See Relief 1B21-F078E VR 10 3

C 0

E-4 1

5 Request 003 C

M05-1002/1 See Relief IB21-F078F VR 10 3

C 0

A-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F078G VR 10 3

C

_0 A-4 1

~5 Request 003

-C M05-1002/1 See Relief 0

C-5 1

5 Request 003 1B21-F078H VR 10 3

C C

M05-1002/1 See Relief IB21-F078J VR 10 3

C O'

E-7 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F078K VR 10 3

C 0

A-5 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F078L VR 10 3

C 0

D-6 1

3 Request 003 i

C M05-1002/1 See Relief 1B21-F078M VR 10 3

C 0

E-3 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F078N VR 10 3

C 0

E-5 1

5 Request 003 l

C M05-1002/1 See Relief 1B21-F078P VR 10 3

C 0

A-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F078R VR 10 3

C 0

D-5 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F078S VR 10 3

C 0

A-3 1

5 Request 003 0

M05-1002/2 See Relief IB21-F098A G

24 2

B MO C

C-3 1,2 5

Request 005 l

0 M05-1002/2 See Relief 1B21-F098B G

24 2

B M0 C

F-3 1,2 5

Request 005 0

M05-1002/2 See Relief IB21-F098C G

24 2

B M0 C

B-3 1,2 5

Request 005 0

M05-1002/2 See Relief IB21-F098D G

24 2

B M0 C

D-3 1,2 5

Request 005 C

M05-1002/1 See Relief 1B21-F379A VR 2

3 C

0 F-7 1

5 Request 003 LJE51A Revision 1

POSITION VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1002/1 See Relief 1B21-F379B VR 2

3 C

0 F-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379C VR 2

3 C

0 F-5 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F379D VR 2

3 C

0 F-4 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F379E VR 2

3 C

0 F-3 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379F VR 2

3 C

0 E-7 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F379G VR 2

3 C

0 E-6 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379H VR 2

3 C

0 E-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379J VR 2

3 C

0 C-6 1

5 Request 003 C

M05-1002/1 See Relief 1B21-F379K VR 2

3 C

0 C-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379L VR 2

3 C

0 B-7 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379M VR 2

3 C

0 B-6 1

5 Request 003 i

C M05-1002/1 See Relief IB21-F379N VR 2

3 C

0 B-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379P VR 2

3 C

0 B-5 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379Q VR 2

3 C

0 B-4 1

5 Request 003 C

M05-1002/1 See Relief IB21-F379R VR 2

3 C

0 B-3 1

5 Request 003 0

See Relief IB21-F433A C

i 3

C C

M10-1004/8 1

5 Request 042 O

See Relief 1B21-F433B C

3 C

C M10-1004/8 1

5 Request 042 C

M05-1072/1 1B33-F019 CV 3/4 2

B A0 C

E-5 1,2 1-5 C

M05-1072/1 1B33-F020 CV 3/4 2

B A0 C

E-8 1,2 1-5 0

M05-1032/3 See Relief ICC049 G

10 2

B MO C

C-8 1,2 5

Request 019 LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS 0

M05-1032/3 See Relief ICC050 G

6 2

B MO C

C-7 1,2 5

Request 019 0

M05-1032/3 See Relief ICC053 G

6 2

B MO C

C-3 1,2 5

Request 019 i

O M05-1032/3 See Relief ICC054 C

10 2

B MO C

C-1 1,2 5

Request 019 0

M05-1032/3 See Relief ICC057 G

8 2

B MO C

D-8 1,2 5

Request 019 0

M05-1032/3 See Relief ICC060 G

8 2

B MO C

C-2 1,2 5

Request 019 0

M05-1032/3 See Relief

~~~ICC065 G

21 3

B M0 C

C-6 1,2 5

Request 036 O

M05-1032/3 See Relief ICC067 G

21 3

B MO C

C-3/4 1,2 5

Request 036 O

M05-1032/3 See Relief ICC068 G

21 3

B MO C

E-6 1,2 5

Request 036

^

0 M05-1032/3 See Relief ICC070 G

2) 3 B

M0 C

E-3 1,2 5

Request 036 C

M05-1032/3 1CC071 G

4 2

B MO 0,C E-2 1,2 1-5 C

M05-1032/3 1CC072 G

4 2

B MO 0,C E-1 1,2 1-5 Rev 1 C

M05-1032/3 1CC073 G

4 2

B MO 0,C F-1 1,2 1-5 C

M05-1032/3 1CC074 C

4 2

B MO 0,C F-2 1,2 1-5 l

0,C M05-1032/2 1CC075A B

14 3

B M0 C

E-3 1,2 1-5 1

0,C M05-1032/2 1CC075B B

14 3

B M0 C

C-3 1.2 1-5 0,C M05-1032/2 1CC076A B

14 3

B MO C

D-2 1,2 1-5 0,C M05-1032/2

{

ICC076B B

14 3

B M0 C

C-2 1,2 1-5 0

M05-1032/3 See Relief ICC127 G

8 2

B MO C

D-8 1,2 5

Request 019 l

0 M05-1032/3 See Relief ICC128 G

8 2

B M0 C

C-2 1,2 5

Request 019 0

M05-1032/3 See Relief C

E-6 1

5 Request 036 i

ICC188A C

21 3

C LJE51A Revision 1

POSITION VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS O

M05-1032/3 See Relief ICC188B C

21 3

C C

C-6 1

5 Request 036 0

M05-1034/1 1CM002A EFC 3/4 2

C C

B-7 1

1-5 0

M05-1034/1 1CM002B EFC 3/4 2

C C

A-7 1

1-5 0

M05-1034/1 1CM003A EFC 3/4 2

C C

B-4 1

1-5 0

M05-1034/1 1CM003B EFC 3/4 2

C C

B-7 1

1-5 0

M05-1034/2 See Relief ICM011 C

3/4 2

B SO 0,C C-7 Request 032 0

M05-1034/2 See Relief j

ICM012 G

3/4 2

B SO 0,C C-6 Request 032 C

M05-1034/2 See Relief ICM014 G

}

2 B

SO O

B-6 Request 032 C

M05-1034/2 See Relief ICM015 G

l 2

B SO O

F-5 Request 032 C

M05-1034/2 See Relief ICM016 G

}

2 B

SO O

E-5 Request 032 C

M05-1034/2 See Relief ICM017 G

l 2

B SO O

D-5 Request 032 C

M05-1034/2 See Relief ICM018 G

}

2 B

SO O

B-5 Request 032 C

M05-1034/2 See Relief ICM022 G

3/4 2

B SO 0,C D-3 Request 032 C

M05-1034/2 See Relief 1 01023 G

3/4 2

B SO 0,C D-3 Request 032 C

M05-1034/2 See Relief ICM025 G

3/4 2

B SO 0,C C-3 Request 032 C

M05-1034/2 See Relief I

1 0:026 G

3/4 2

B SO 0,C C-3 Request 032 C

M05-1034/2 See Relief ICM028 G

l 2

B SO O

B-3 Request 032 C

M05-1034/2 See Relief ICM031 G

2 B

SO O

B-4 Request 032 C

M05-1034/2 See Relief ICM032 G

}

2 B

SO O

D-4 Request 032 C

M05-1034/2 See Relief ICM033 G

}

2 B

SO O

E-4 Request 032 LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ALTUATOR TEST COORD METH COND COMMENTS C

M05-1034/2 See Relief ICM034 G

}

2 B

SO O

F-4 Request 032 0

M05-1034/2 See Relief ICM047 G

3/4 2

B SO 0,C D-6 Request 032 0

M05-1034/2 See Relief ICM048 G

3/4 2

B SO 0,C D-7 Request 032 0

M05-1034/2 1CM051 EFC 3/4 2

C C

C-6 1

1-5 0

M05-1034/3 1CM053 EFC 3/4 2

C C

C-5 1

1-5 0

M05-1071/1 See Relief ICM066 EFC 3/4 2

C C

F-3 1

5 Request 037 0

M05-1071/1 See Relief ICM067 EFC 3/4 2

C C

E-6 1

5 Request 037 0

M05-1012/6 1CY016 G

6 2

B MO C

C-6 1.2 1-5 0

M05-1012/6 1CY017 G

6 2

B M0 C

C-6 1,2 1-5 0

M05-1012/6 1CY020 G

3 2

B M0 C

D-3 1,2 1-5 0

M05-1012/6 1C7021 G

3 2

B M0 C

D-2 1,2 1-5 0

1C11-F010 GL 1

2 B

AO 0,C CLN-001 1,2,7 1-5 0

IC11-F011 GL 2

2 B

A0 0,C CLN-001 1,2,7 1-5 O

M05-1078/1 See Relief IC11-F083 CL 2

2 B

M0 C

C-7 1,2 5

Request 008 0

M05-1078/1 See Relief IC11-F122 C

2 2

C C

C-7 Request 010 0

1C11-F180 GL 1

2 B

A0 0,C CLN-001 1,2 1-5 0

1C11-F181 GL 2

2 B

A0 0,C CLN-001 1,2 1-5 m

C M05-1077 1C41-F001A GL 3

2 B

MO O

C-6 1,2 1-5 4

LJE51A Revision 1

l POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1077 1C41-F001B GL 3

2 B

MO O

E-6 1,2 1-5 l

C M05-1077 l

IC41-F004A EX 1}

1 D

M N/A C-3 4

4-5 l

C M05-1077 j

IC41-F004B EX 1}

1 D

M N/A D-3 4

4-5 C

M05-1077 See Relief 1C41-F006 NC 3

1 C

0 D-2 1

5 Request 011 C

M05-1077 1C41-F029A R

lix2 2

C 0

C-4 5

4,5 C

M05-1077 1C41-F029B R

1}x2 2

C 0

E-4 5

4,5 C

M05-1077 1C41-F033A NC 1) 2 C

0 C-4 1

1-5 C

M05-1077 1C41-F033B NC 1}

2 C

0 E-4 1

1-5 C

M05-1077 1C41-F0336 C

4 1

C 0

E-1 1

1-5 C

M05-1035/1 1DG006A R

i 3

C 0

E-6 5

4,5 C

M05-1035/1 1DG006B R

}

3 C

0 D-6 5

4,5 C

M05-1035/2 1DG006C R

1 3

C 0

E-6 5

4,5 C

M05-1035/2 1DG006D R

3 C

0 D-6 5

4,5 C

M05-1035/3 1DG006E R

i 3

C 0

E-6 5

4,5 C

M05-1035/3 1DG006F R

3 C

0 D-6 5

4,5 O

M05-1035/1 See Relief 1DG007A CV 2

3 B

M C

E-4 Request 038 O

M05-1035/1 See Relief IDG007B CV 2

3 B

M C

C-4 Request 038 0

M05-1035/2 See Relief 1DG007C CV 2

3 B

M C

E-4 Request 038 0

M05-1035/2 See Relief IDG007D CV 2

3 B

M C

C-4 Request 038 l

l LJE51A Revision 1 i

o l

-=

J l

POSITION VALVE NORM P&TD TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS 0

M05-1035/3 See Relief IDG007E CV 2

3 B

M C

E-4 Request 038 0

M05-1035/3 See Relief IDG007F CV 2

3 B

M C

C-4 Request 038 1

0 M05-1035/1 See Relief Request 038 IDG007G CV 2

3 B

M C

F-4 l

0 M05-1035/1 See Relief 1DG007H CV 2

3 B

M C

B-4 Request 038 0

M05-1035/2 See Relief I

1DG007J CV 2

3 B

M C

F-4 Request 038 l

0 M05-1035/2 See Relief i

1DG007K CV 2

3 B

M C

B-4 Request 038 C

M05-1035/1 See Relief 1DG008A MFC 2

3 B

0 E-3 Request 038 C

M05-1035/1 See Relief 1DG008B MFC 2

3 B

0 C-3 Request 038 C

M05-1035/1 See Relief 1DG008C MFC 2

3 B

0 F-3 Request 038 C

M05-1035/1 See Relief 1DG008D MFC 2

3 B

0 B-3 Request 038 C

M05-1035/2 See Relief 1DG008E MFC 2

3 B

0 E-3.

Request 038 C

M05-1035/2 See Relief 1DG008F MFC 2

3 B

0 C-3 Request 038 C

M05-1035/2 See Relief 1DG008G MFC 2

3 B

0 F-3 Request 038 C

M05-1035/2 See Relief 1DG008H MFC 2

3 B

0 B-3 Request 038 C

M05-1035/3 See Relief 1DG008J MFC 2

3 B

0 E-3 Request 038 C

M05-1035/3 See Relief j

1DG008K MFC 2

3 B

0 D-3 Request 038 I

1 C

M05-1036/1 1

1D0001A C

11 3

C 0

B-1 1

1-5

]

C M05-1036/1 1D0001B C

li 3

C 0

B-5 1

1-5 C

M05-1036/2 j

1D0001C C

1}

3 C

0 B-3 1

1-5 W

LJE51A Revision 1 I

POSITION VALVE WORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1036/1 1D0005A R

3/4x1 3

C O

C-1 5

4,5 C

M05-1036/1 1D0005B R

3/4x1 3

C O

C-5 5

4,5 C

M05-1036/2 0

C-3 5

4,5 1D0005C R

3/4x1 3

C 0

M05-1075/4 1E12-F003A CL 14 2

B MO 0,C C-2 1,2 1-5 O

M05-1075/4 1E12-F003B GL 14 2

B MO 0,C C-7 1,2 1-5 0

M05-1075/1 1E12-F004A G

20 2

B MO 0,C A-4 1,2 1-5 0

M05-1075/2 l

l 1E12-F004B G

20 2

B MO 0,C A-6 1,2 1-5 C

M05-1075/1 1E12-F005 R

1)x2 2

C 0

B-5 5

4,5 C

M05-1075/1 1E12-F006A G

16 2

B MO O

A-5 1,2 1-5 C

M05-1075/2 l

1E12-F006B G

16 2

B MO O

A-6 1,2 1-5 C

M05-1075/1 See Relief IE12-F008 G

18 1

A MO 0,C B-4 1,2,3 5

Request 054 C

M05-1075/1 See Relief IE12-F009 G

18 1

A M0 0,C B-2 1,2,3 5

Request 054 C

M05-1075/4 1E12-F011A GL 4

2 B

MO 0,C D-4 1,2 1-5

'-~

C M05-1075/4 1E12-F011B GL 4

2 B

MO 0,C C-3 1,2 1-5 C

M05-1052/1 1E12-F014A G

18 3

B MO O

D-2 1,2 1-5 l

C M05-1052/2 1E12-F014B G

18 3

B MO O

D-2 1,2 1-5 C

M05-1075/1 l

1E12-F017A R

1}x2 2

C 0

B-6 5

4,5 C

M05-1075/2 1E12-F017B R

1}x2 2

C 0

B-6 5

4,5 C

M05-1075/2 1E12-F019 C

4 1

C 0

C-5 1

1-5 LJE51A Revision 1

POSITION 2

VALVE NORM P&ZD TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1075/3 1E12-F021 GL 14 2

B MO 0,C D-3 1,2 1-5 C

M05-1075/2 See Relief IE12-F023 GL 4

1 A

MO 0.C C-5 1,2,3 5

Request 054 C

M05-1075/1 1E12-F024A G

14 2

B MO 0,C C-7 1,2 1-5 C

M05-1075/1 1E12-F024B C

14 2

B MO 0,C C-2 1,2 1-5 C

M05-1075/1 0

D-4 5

4,5 1E12-F025A R

lx1) 2 C

C M05-1075/2 0

E-5 5

4,5 1E12-F025B R

lx1) 2 C

C M05-1075/3 1E12-F025C R

lx1) 2 C

0 F-3 5

4,5 C

M05-1075/4 IE12-F026A G

4 2

B MO 0,C E-3 1,2 1-5 C

M05-1075/4 IE12-F026B C

4 2

B MO 0,C E-6 1,2 1-5 l

0 M05-1075/1 i

1E12-F027A G

12 2

B MO 0,C D-4 1,2 1-5

}

O M05-1075/2 1E12-F027B C

12 2

B MO 0,C D-5 1,2 1-5 C

M05-1075/1 IE12-F028A G

10 2

B MO 0,C F-3 1,2 1-5 C

M05-1075/2 j

1E12-F028B G

10 2

B MO 0,C F-6 1,2 1-5 C

M05-1075/1 0,C B-8 1

1-5 1E12-F031A NC 14 2

C 4

C M05-1075/2 1E12-F031B NC' 14 2

C 0,C B-1 1

1-5 C

M05-1075/3 0,C D-1 1

1-5 i

1E12-F031C NC 14 2

C C

M05-1075/4 0

E-5 5

4,5 IE12-F036 R

4x6 2

C C

M05-1075/1 See Relief IE12-F041A NC 12 1

A/C A0 0

D-2 1,3 5

Request 054 C

M05-1075/2 See Relief 1E12-F041B NC 12 1

A/C AO O

D-7 1,3 5

Request 054 l

i LJE51A Revision 1

POSITION VALVE NORM P&ID TEST TEST y

NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1075/3 See Relief IE12-F041C NC 12 1

A/C AO O

E-7 1,3 5

Request 054 C

M05-1075/1 See Relief IE12-F042A G

12 1

A MO O

D-3 1,2,3 5-Request 054 C

M05-1075/2 See Relief IE12-F042B G

12 1

A MO O

D-6 1,2,3 5

Request 054 C

M05-1075/3 See Relief IE12-F042C G

12 1

A MO O

E-5 1,2,3 5

Request 054 0,C M05-1075/1 0

B-7 1

1-5 1E12-F046A C

4 2

C 0,C M05-1075/2 0

B-2 1

1-5 IE12-F046B C

4 2

C 0,C M05-1075/3 1E12-F046C C

4 2

C 0

B-2 1

1-5 O

M05-1075/4 IE12-F047A G

14 2

B M0 C

C-2 1,2 1-5 0

M05-1075/4 1E12-F047B G

14 2

B M0 C

C-8 1,2 1-5 0

M05-1075/1 1E12-F048A GL 14 2

B MO 0,C C-8 1,2 1-5 0

M05-1075/2 1E12-F048B GL 14 2

B MO 0,C C-1 1,2 1-5 C

M05-1075/1 See Relief IE12-F050A NC 10 2

A/C 0

D-5 1,3 5

Request 054 C

M05-1075/2 See Relief IE12-F050B NC 10 2

A/C 0

E-5 1,3 5

Request 054 0,C M05-1075/4 1E12-F051A CV 6

2 B

A0 0,C E-3 1,2 1-5 i

0,C M05-1075/4 1E12-F051B CV 6

2 B

A0 0,C E-7 1,2 1-5 0,C M05-1075/4 1E12-F052A GL 8

2 B

MO 0,C E/F-3/4 1,2 1-5 j

0,C M05-1075/4 IE12-F052B GL 8

2 B

MO 0,C E/F-5/6 1,2 1-5 1

C M05-1075/1 See Relief 1E12-F053A GL 10 2

A MO 0,C D-6 1,2,3 5

Request 054 C

M05-1075/2 See Relief IE12-F053B GL 10 2

A MO 0,C E-4 1,2,3 5

Request 054 0,C M05-1075/4 IE12-F054A C

4 2

C 0

D-3 1

1-5 LJE51A Revision 1 N

l POSITION l

VALUE NORM P&ID TEST TEST hTMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS l

0,C' M05-1075/4 1E12-F054B C

4 2

C 0

D-6 1

1-5 C

M05-1075/4 IE12-F055A R

8x12 2

C 0

C-2 5

4,5 See Note 3 C

M05-1075/4 l

l 1E12-F055B R

8x12 2

C 0

C-7 5

4,5 See Note 3 C

M05-1075/4 See Relief l

1E12-F060A 2-way 3/4 2

B SO O

B-4 1,7 1-5 Request 045 C

M05-1075/4 See Relief I

1E12-F060B 2-wav 3/4 2

B SO O

B-5 1,7 1-5 Request 045 0

M05-1075/1 1E12-F064A G

4 2

B MO 0,C B-8 1,2 1-5 0

M05-1075/2 1E12-F064B G

4 2

B MO 0,C B-1 1,2 1-5 o

O M05-1075/3 1E12-F064C G

4 2

B MO 0,C B-1 1,2 1-5 0,C M05-1075/4 l

IE12-F065A CV 2) 2 B

A0 0,C D-3 1,2 1-5 1

0,C M05-1075/4 1E12-F065B CV 2}

2 B

A0 0,C C-6 1,2 1-5 C

M05-1052/1 1E12-F068A G

18 3

B MO O

C-1 1,2 1-5 C

M05-1052/2 i

l 1E12-F068B C

18 3

B MO O

C-1 1,2 1-5 l

C M05-1075/1 1E12-F073A CL li 2

B MO O

C-3 1,2 1-5 C

M05-1075/2 1E12-F073B GL li 2

B MO O

B-7 1,2 1-5 C

M05-1075/1 1E12-F074A CL 11 2

B MO O

C-4 1,2 1-5 C

M05-1075/2 1E12-F074B GL li 2

B MO O

B-5 1,2 1-5 C

M05-1075/4 See Relief IE12-F075A 2-way 3/4 2

B SO O

B-4 1,7 1-5 Request 045 C

M05-1075/4 See Relief l

1E12-F075B 2-way 3/4 2

B SO O

B-5 1,7 1-5 Request 045 0

M05-1075/1 lE12-F084A C

21 2

C C

B-7 1

1-5 0

M05-1075/2 l

1E12-F084B C

21 2

C C

B-2 1

1-5 l

l LJE51A Revision 1

C

~

POSITION VALVE NORM P&lD TEST

  • TEST 1

NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS O

M05-1075/3 i

1E12-F084C C

2) 2 C

C E-2 1

1-5 I

LO M05-1075/1 1E12-F085A GSC 2

2 C

O.C B-8 1

1-5

)

LO M05-1075/2 1E12-F085B GSC 2

2 C

0,C B-1 1

1-5 4

l LO M05-1075/3 1E12-F085C CSC 2

2 C

0,C E-1 1

1-5 C

M05-1075/4 1E12-F087A CL 6

2 B

MO 0,C E-3 1,2 1-5 C

M05-1075/4 1E12-F087B GL 6

2 B

MO 0,C E-6 1,2 1-5 3

C M05-1075/4 i

1E12-F094 G

4 3

B MO O

E-7/8 1,2 1-5 0

M05-1075/4 See Relief j

1 1E12-F095 2-way 3/4 2

B SO C

E-7 1,7 1-5 Request 045 I

C M05-1075/4 1E12-F096 G

4 2

B MO O

E-7/8 1,2 1-5 C

M05-1075/4 1E12-F098 C

4 2

C 0

D-7 1

1-5 4

C M05-1075/3 1E12-F101 R

1xil 2

C 0

C-5 5

4,5 i

C M05-1075/4 l

IE12-F103A VR 2

C 0

B-1 1

1-5 C

M05-1075/4 i

1E12-F103B VR 2

2 C

0 B-8 1

1-5 C

M05-1075/4 IE12-F104A VR 2

2 C

O B-1 1

1-5 C

M05-1075/4 IE12-F104B VR 2

2 C

O B-8 1

1-5 i

O M05-1075/3 1E12-F105 G

20 2

B MO 0,C B-5 1,2 1-5 C

M05-1075/4 1E12-F110A VR 2

2 C

0 B-3 1

1-5 C

M05-1075/4 1E12-F110B VR 2

2 C

0 B-7 1

1-5 1

J I

LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NI:MBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1075/4 IE12-F111A VR 2

2 C

0 B-3 1

1-5 C

M05-1075/4 1E12-F111B VR 2

2 C

0 B-7 1

1-5 0

M05-1073 1E21-F001 G

20 2

B MO 0,C B-4 1,2 1-5 iRev 1 C

M05-1073 IE21-F003 NC 12 2

C 0

E-6 1

1-5 1,

C M05-1073 See Relief 1E21-F005 C

10 1

A MO O

E-4 1,2,3 5

Request 054 C

M05-1073 See Relief IE21-F006 NC 10 1

A/C A0 0

E-2 1,3 5

Request 054 O

M05-1073

)

lE21-F011 G

4 2

B MO 0,C D-6 1,2 1-5 l

C M05-1073 1E21-F012 GL 10 2

B MO 0,C D-5 1,2 1-5 C

M05-1073 IE21-F018 R

lix2 2

C 0

E-5 5

4,5 C

M05-1073 1E21-F031 R

1}xl 2

C 0

C-8 5

4,5 0

M05-1073 IE21-F033 C

2}

2 C

C D-6 1

1-5 LO M05-1073 IE21-F034 GSC 2

2 C

C D-6 1

1-5 C

M05-1073 1E21-F303 NC 10 2

C 0

C-5 1

1-5 C

M05-1073 See Relief IE21-F306 C

3 2

C 0,C F-4 1

5 Request 041 0

M05-1074 1E22-F001 G

16 2

B MO 0,C A-6 1,2 1-5 1

0 M05-1074 IE22-F002 C

16 2

C C

A-5 1

1-5 C

M05-1074 See Relief

Rev 1 lE22-F004 G

10 1

A MO 0,C E-7 1,2,3 5

Request 054 i

C M05-1074 See Relief IE22-F005 NC 10 1

A/C A0 0,C E-8 1,3 5

Request 054 0

M05-1074 IE22-F006 GSC 2

2 C

M C

D-4 1

1-5 0

M05-1074 I

1E22-F007 C

2}

2 C

C D-4 1

1-5 i

LJE51A Revision 1 i

T POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1074 1E22-F010 GL 10 2

B MO C

D-6 1,2 1-5 C

M05-1074 IE22-F011 GL 10 2

B M0 C

D-5 1,2 1-5 C

M05-1074 1E22-F012 G

4 2

B MO 0,C D-3 1,2 1-5 C

M05-1074 1E22-F014 R

1x3/4 2

C 0

C-5 5

4,5 C

M05-1074 1E22-F015 C

20 2

B M0 O

B-7 1,2 1-5 C

M05-1074 IE22-F016 C

20 2

C 0,C B-6 1

1-5 C

M05-1074 IE22-F023 CL 10 2

B MO 0,C D-6 1,2 1-5 C

M05-1074 IE22-F024 NC 14 2

C 0

E-3 1

1-5 t

C M05-1074 I

IE22-F035 R

1x3/4 2

C 0

E-3 5

4,5 l

C M05-1074 l

IE22-F039 R

1x3/4 2

C 0

C-6 5

4,5 0

1E22-F330 EFC 3/4 2

C C

M10-1074/3 1

1-5 0

l 1E22-F332 EFC 3/4 2

C C

M10-1074/3 1

1-5 0

M05-1041/4 See Relief IE31-F014 C

1 2

B SO C

E-8 1

1-5 Request 033 0

M05-1041/4 See Relief IE31-F015 C

1 2

B SO C

E-7 1

1-5 Request 033 C

M05-1041/4 See Relief IE31-F016 C

1 2

B SO E-8 Request 040 0

M05-1041/4 See Relief IE31-F017 G

1 2

B SO C

C-7 1

1-5 Request 033 0

M05-1041/4 See Relief f

IE31-F018 G

1 2

B SO C

C-8 1

1-5 Request 033 l

C M05-1041/4 See Relief IE31-F019 G

1 2

B SO C-8 Request 040 C

M05-1070 l

IE32-F001A GL 1}

l B

MO 0,C C-7 1,2 1-5 l

C M05-1070 1E32-F001E CL 1}

1 B

MO 0,C E-7 1,2 1-5 LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1070 1E32-F001J GL li 1

B MO 0,C B-7 1,2 1-5 C

M05-1070 1E32-F001N GL li 1

B MO O.C D-7 1,2 1-5 C

M05-1070 1E32-F002A CL 1}

2 B

MO 0,C C-7 1,2 1-5 C

M05-1070 1E32-F002E CL 1) 2 B

MO 0,C E-7 1,2 1-5 C

M05-1070 1E32-F002J GL li 2

B MO O.C B-7 1,2 1-5 C

M05-1070 1E32-F002N GL li 2

B MO 0,C D-7 1,2 1-5 C

M05-1070 1E32-F003A GL li 2

B MO 0,C C-7 1,2 1-5 C

M05-1070 1E32-F003E GL 1}

2 B

MO 0,C E-7 1,2 1-5 C

M05-1070 1E32-F003J GL li 2

B MO 0,C B-7 1,2 1-5 C

M05-1070 1E32-F003N CL 1}

2 B

MO 0,C D-7 1,2 1-5 C

M05-1070 1E32-F006 G

21 2

B MO 0,C C-4 1,2 1-5 C

M05-1070 IE32-F007 G

2}

2 B

MO 0,C C-3 1,2 1-5 C

M05-1070 1E32-F008 G

21 2

B MO 0,C A-4 1,2 1-5 C

M05-1070 1E32-F009 G

2) 2 B

MO 0,C A-3 1,2 1-5 C

M05-1070 1E32-F010 C

3/4 2

C OC E-4 1

1-5 C

M05-1070 1E32-F011 C

3/4 2

C O.C B-2 1

1-5 C

M05-1070 1E32-F315A C

3/4 2

C 0

A-4 1

1-5 C

M05-1070 O

A-4 1

1-5 1E32-F315B C

3/4 2

C C

M05-1070 1E32-F315C C

3/4 2

C 0

A-4 1

1-5 C

M05-1070 1E32-F315D C

3/4 2

C O

A-4 1

1-5 LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST y

NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS O

M05-1079/2 Dev 1 1E51-C002E G

4 2

B MO 0,C D-3 1,2 1-5 O

M05-1079/2 1E51-F010 G

6 2

B MO 0,C A-6 1,2 1-5 C

M05-1079/2 1E51-F011 C

6 2

C 0

A-4 1

1-5 C

M05-1079/2 See Relief IE51-F013 C

6 1

A MO 0,C F-6 1,2,3 5

Request 054 0

M05-1079/2 See Relief IE51-F015 CV 1

2 SC C-4 Request 046 C

M05-1079/2 O

C-5 5

4,5 1E51-F018 R

2x3 2

C C

M05-1079/2 1E51-F019 CL 2

2 B

MO 0,C D-6 1,2 1-5 C

M05-1079/2 1E51-F021 C

2) 2 C

0 D-5 1

1-5 C

M05-1079/2 1E51-F022 CL 4

2 B

MO 0,C E-5 1,2 1-5 0

M05-1079/1 1E51-F025 CV 1

2 B

A0 0,C D-5 1,2,7 1-5 O

M05-1079/1 1E51-F026 CV 1

2 B

A0 0,C D-5 1,2,7 1-5 C

M05-1079/2 0

B/C-4 1

1-5 1E51-F030 C

6 2

C C

M05-1079/2 i

1E51-F031 G

6 2

B MO 0,C B/C-6 1,2 1-5 C

M05-1079/1 0

C-4 1

1-5 1E51-F040 C

12 2

C C

M05-1079/1 1E51-F045 GL 4

2 B

MO O

D-4 1,2 1-5 C

M05-1079/1 1E51-F046 GL 2

2 B

MO O

C-3/4 1,2 1-5 C

M05-1079/1 0,C B-1 1

1-5 1E51-F047 C

2) 2 C

C M05-1079/2 1E51-F059 G

4 2

B MO C

E-5 1,2 1-5 0

M05-1079/1 0,C B-4 1

1-5 1E51-F061 C

2) 2 C

0 M05-1079/1 1E51-F063 G

8 1

B MO 0,C E-8 1,2 1-5 LJE51A Revision 1

i J

POSITION 2

l VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUITOR TEST COORD METH COND COMMENTS 0

M05-1079/1 1E51-F064 G

8 1

B MO 0,C E-5 1,2 1-5 C

M05-1079/2 1E51-F065 NC 4

1 C

0 E/F-6/7 1

1-5 C

M05-1079/2 See Relief IE51-F066 NC 4

1 A/C A0 0

F-8 1,3 5

Request 054 0

M05-1079/2 1E51-F068 G

12 2

B M0 C

C-5 1,2 1-5 C

M05-1079/1 Rev 1 i

l 1E51-F076 GL 1

1 B

MO 0,C E-8 1,2 1-5 l

0 M05-1079/1 1E51-F077 CL 1}

2 B

M0 C

C-5 1,2 1-5 0

M05-1079/1 1E51-F078 G

3 2

B MO C

C-6/7 1,2 1-5 C

M05-1079/1 IE51-F079 VR 2

2 C

0 C-6 1

1-5 C

M05-1079/1 0

C-6 1

1-5 1E51-F081 VR 2

2 C

C M05-1079/2 0

E-5 5

4,5 1E51-F090 R

3/4x1 2

C C

M05-1079/1 1E51-F095 C

1 2

B MO 0,C D-4 1,2 1-5 0

C M10-1079/2 1

1-5 1E51-F377A EFC 3/4 2

C l

0 C

M10-1079/2 1

1-5 l

1E51-F377B EFC 3/4 2

C 0,C M05-1037/3 l

l IFC004A CV 8

3 B

A0 0

E-5 1,2,7 1-5 0,C M05-1037/3 IFC004B CV 8

3 B

A0 0

A/B-5 1,2,7 1-5 O

M05-1037/1

{

1FC007 G

10 2

B Mo C

B-2 1,2 1-5 0

M05-1037/1 IFC008 G

10 2

B MO C

B-1/2 1,2 1-5 0,C M05-1037/3 l

1FC011A B

14 3

B M0 C

E-7/8 1,2 1-5 0,C M05-1037/3 IFC011B B

14 3

B M0 C

A-7/8 1,2 1-5 l

LJE51A Revision 1 1

POSITION VALVE NORM P&lD TEST TEST y

NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS 0,C M05-1037/3 IFC013A NC 14 3

C C

E-7 1

1-5 0,C M05-1037/3 l

1FC013B NC 14 3

C C

A-7 1

1-5 0,C M05-1037/3 1FC015A B

14 3

B MO C

E-2 1,2 1-5 O,C M05-1037/3 IFC015B B

14 3

B M0 C

A-2 1,2 1-5 0,C M05-1037/3 IFC016A B

8 3

B M0 C

D-6/7 1,2 1-5 0,C M05-1037/3 IFC016B B

8 3

B M0 C

D-6/7 1,2 1-5 0

M05-1037/3 5

IFC017 B

8 3

B A0 C

C-6 1,2,7 1-5 0

M05-1037/3 1FC023 B

8 3

B A0 C

C/D-3 1,2,7 1-5 0,C M05-1037/3 IFCO24A B

8 3

B MO C

D/E-2/3 1,2 1-5 j

0,C M05-1037/3 J

IFC024B B

8 3

B M0 C

C-2/3 1,2 1-5 1

0,C M05-1037/3 1FCO26A

'B 14 3

B MO C

E-2 1,2 1-5 0,C M05-1037/3 IFCO26B B

14 3

B M0 C

B-2 1,2 1-5 0

M05-1037/1 IFC036 G

8 2

B MO C

E-1 1,2 1-5 0

M05-1037/2 IFC037 G

8 2

B MO C

E-2 1,2 1-5 1

4 0

M05-1039/9 i

IFP050 C

6 2

B M0 C

D-3 1,2 1-5 I

O M05-1039/9 j

IFP051 C

10 2

B MO C

C-7/8 1,2 1-5 0

M05-1039/9 lj IFP052 C

10 2

B M0 C

C-6/7 1,2 1-5 i

0 M05-1039/9 IFP053 G

10 2

B MO C

C-4 1,2 1-5 O

M05-1039/9 1

IFP054 G

10 2

B M0 C

C-2 1,2 1-5 l

LJE51A Revision 1 i

-.s

POSITION VALVE NORM P&ID TEST TEST l

NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS i

o M05-1039/9 IFP078 G

4 2

B MO C

D-5 1,2 1-5 0

M05-1039/9 1FP079 G

4 2

B MO C

D-6 1,2 1-5 0

M05-1039/9 1FP092 G

6 2

B MO C

D-3 1,2 1-5 0

M05-1076/4 1G33-F001 G

6 1

A MO C

B-8 1,2,3 1-5 0

M05-1076/4 IG33-F004 G

6 1

A M0 C

B-5 1,2,3 1-5 C

M05-1076/4 1G33-F028 G

4 2

B M0 C

E-8 1,2 1-5 C

M05-1076/4 IG33-F034 C

4 2

B MO C

E-7 1,2 1-5 0

M05-1076/4 1G33-F039 C

4 2

B M0 C

D-7 1,2 1-5 0

M05-1076/4 1G33-F040 C

4 2

B M0 C

D-8 1,2 1-5 0

M05-1076/4 See Relief Request 047 1G33-F051 NC 4

2 C

D-6 0

M05-1076/4 See Relief 1G33-F052A NC 4

2 C

D-5 Request 047 0

M05-1076/4 See Relief 1G33-F052B NC 4

2 C

D-5 Request 047 0

M05-1076/4 1G33-F053 G

4 2

B M0 C

C-8 1,2 1-5 0

M05-1076/4 1G33-F054 G

4 2

B MO C

C-7 1,2 1-5 C

M05-1063 1HG001 B

2 2

B MO 0,C D-3 1,2 1-5 C

M05-1063 1HG004 B

2 2

B MO 0,C C-3 1,2 1-5 C

M05-1063 1HG005 B

2 2

B MO O.C E-3 1,2 1-5 C

M05-1063 1HG008 B

2 2

B MO 0,C E-3 1,2 1-5 LJE51A Revision 1

POSITION 2

VALVE NORM P&ID TEST TEST NLNEER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1063 1HG009A C

6 2

B MO O

E-4/5 1,2 1-5 C

M05-1063 1HG009B G

6 2

B MO O

E-6/7 1,2 1-5 C

M05-1063 IHCC10A VR 10 2

C O

C /D-4 1

1-5 C

M05-1063 O

C/D-7 1

1-5 1HG010B VR 10 2

C C

M05-1063 1HC0100 VR 10 2

C 0

B/C-4 1

1-5 C

M05-1063 0

B/C-7 1

1-5 1HC010D VR 10 2

C C

M05-1063 1HG011A VR 10 2

C O

C/D-4 /5 1

1-5 C

M05-1063 1HC011B VR 10 2

C O

C /D-6/7 1

1-5 C

M05-1063 0

B/C-4/5 1

1-5 1HG011C VR 10 2

C C

M05-1063 O

B/C-6/7 1

1-5 1HG011D VR 10 2

C O

M05-1040/5 IIA 005 CV 3

2 B

AO C

D/E-2 1,2,7 1-5 O

M05-1040/5 IIA 006 CV 3

2 B

AO C

D/E-5 1,2,7 1-5 0

M05-1040/5 IIA 007 CV 3

2 B

AO C

D/E-5 1,2,7 1-5 O

M05-1040/5 IIA 008 CV 3

2 B

AO C

D/E-6/7 1,2,7 1-5 0,C M05-1040/7 See Relief 11A012A CL 1

2 B

MO O.C D/E-2/3 1,2 5

Request 028 O

M05-1040/7 See Relief IIA 012B GL 1

2 B

MO 0,C C /D-3 1,2 5

Request 028 0,C M05-1040/7 See Relief 11A013A GL 1

2 B

MO 0,C D/E-7 1,2 5

Request 028 0,C M05-1040/7 See Relief IIA 013B CT.

1 2

B MO 0,C C /D-6/7 1,2 5

Request 028 O

M05-1040/7 See Relief IIA 042A C

1 2

C C

D/E-6 1

5 Request 042 O

M05-1040/7 See Relief C

D/E-4 1

5 Request 042 IIA 042B C

1 2

C LJE51A Revision 1 i

____-___.___..________m.___.

POSITION 2

VALVE NORM P&ID TEST TEST

. NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS Rev 1 O

M05-1040/7 See Relief IIA 044A CV 1

3 B

SC D-7 Request 044 0

M05-1040/7 See Relief Request 044 D-2 IIA 044B CV 1

3 B

SC C

M05-1040/7 IIA 128A R

1xli 2

C 0

E-4 5

4,5 C

M05-1040/7 IIA 128B R

1xll 2

C 0

E-6 5

4,5 0

M05-1042/4 OMC009 G

4 2

B MO C

E-5 1,2 1-5 0

M05-1042/4 OMC010 G

4 2

B MO C

D-5 1,2 1-5 t

C M05-1045/12 See' Relief IPS004 C

3/4 2

B SO C

E-6 Request 043 C

M05-1045/12 See Relief IPS005 C

3/4 2

B SO C

E-6 Request 043 C

M05-1045/12 See Relief IPS009 C

3/4 2

B SO C

E-6 Request 043 C

M05-1045/12 See Relief IPS010 G

3/4 2

B SO C

E-5 Request 043 C

M05-1045/12 See Relief IPS016 G

i 2

B SO C

E-5 Request 043 C

M05-1045/12 See Relief IPS017 G

i 2

B SO C

E-5 Request 043 C

M05-1045/12 See Relief IPS022 C

i 2

B SO C

E-4 Request 043 C

M05-1045/12 See Relief IPS023 C

i 2

B SO C

E-4 Request 043 C

M05-1045/12 See Relief IPS031 C

3/4 2

B SO C

E-2 Request 043 C

M05-1045/12 See Relief IPS032 G

3/4 2

B SO C

E-2 Request 043 C

M05-1045/12 See Relief Request 043 IPS034 G

3/4 2

B SO C

F-1 C

M05-1045/12 See Relief IPS035 G

3/4 2

B SO C

E-1 Request 043 i

LJE51A Revision 1

_.. _. _ __. _ - - _ _ ___._..- __ _ _ _. -. _ _ _ _.. = _ _ _. _ __.

POSITION UALVE NORM P&ID TEST TEST l

l NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS l

C M05-1045/12 See Relief Request 043 l

IPS037 G

3/4 2

B SO C

E-8 C

M05-1045/12 See Relief Request 043

3/4 2

B SO C

E-8 C

M05-1045/12 See Relief IPSO 43A G

3/4 2

B SO C

F-2 Request 043 C

M05-1045/12 See Relief Request 043 IPSO 43B C

3/4 2

B SO C

F-3 C

M05-1045/12 See Relief IPSO 44A G

3/4 2

B SO C

E-2 Request 043 C

M05-1045/12 See Relief IPSO 44B G

3/4 2

B SO C

E-3 c-Request 043 C

M05-1045/12 See Relief IPSO 47 G

3/4 2

B SO C

F-7 Request 043 C

M05-1045/12 See Relief IPSO 48 G

3/4 2

B SO C

E-7 Request 043 C

M05-1045/12 See Relief i

Request 043

'IPS055 C

}

2 B

SO C

C-3 C

M05-1045/12 See Relief Request 043 IPS056 G

}

2 B

SO C

C-3 IPS069 G

}

2 B

SO C

-M05-1045/12 See Relief C

B-3 Request 043 C

M05-1045/12 See Relief Request 043 IPS070 G

}

2 B

SO C

B-3 e

O M05-1065/7 See Relief ORA 026 CV 1

2 B

A0 C

D-8 1,7 1-5 Request 027 0

M05-1065/7 See Relief ORA 027 CV 1

2 B

A0 C

D-7 1,7 1-5 Request 027 0

M05-1065/7 See Relief ORA 028 CV 1

2 B

A0 C

D-6 1,7 1-5 Request 027 0

M05-1065/7 See Relief ORA 029 CV 1

2 B

A0 C

D-5 1,7 1-5 Request 027 C

M05-1065/8 1RA016A R

1x1) 3 C

0 C-7 5

4,5 C

M05-1065/8 1RA016B R

1x1}

3 C

0 C-3 5

4,5 I

LJE51A Revision 1

1 i

POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS O

M05-1065/8 See Relief Request 044 C-7 1RA017A CV i

3 B

SC i

0 M05-1065/8 See Relief Request 044 IRA 017B CV i

3 B

SC C-3 0,C M05-1046/4 1RE019 CV 3

2 B

A0 C

A-7 1,2,7 1-5 0,C M05-1046/3 1RE020 CV 3

2 B

A0 C

A-4 1,2,7 1-5 0,C M05-1046/3 1RE021 CV 3

2 B

A0 C

A-5 1,2,7 1-5 0,C M05-1046/3 1RE022 CV 3

2 B

A0 C

A-7 1,2,7 1-5 0,C M05-1047/3 1RF019 CV 3

2-B A0 C

C-2 1,2,7 1-5 0,C M05-1047/3 1RF020 CV 3

2 B

A0 C

C-2 1,2,7 1-5 0,C M05-1047/3 1RF021 CV 3

2 B

A0 C

C-5 1,2,7 1-5 0,C M05-1047/3 1RF022 CV 3

2 B

A0 C

C-5 1,2,7 1-5 M05-1048/6 ISA029 CV 3

2 B

AO C

D/E-2 1,2,7 1-5 0

M05-1048/6 ISA030 CV 3

2 B

A0 C

D/E-3 1,2,7 1-5 0

M05-1048/6 ISA031 CV 3

2 B

A0 C

D/E-4 1,2,7 1-5 0

M05-1048/6 ISA032 CV 3

2 B

A0 C

D/E-5 1,2,7 1-5 C

M05-1060 ISF001 C

10 2

B MO 0,C E-5 1,2 1-5 C

M05-1060 ISF002 C

10 2

B MO 0,C E-5/6 1,2 1-5 Revision 1 LJE51A - -

_ = _ - - - - - - - - _ _ _. -.

POSITION 2

VALVE NORM P&ID TEST TEST NDIBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1060 ISF004 G

12 2

B MO 0,C C-5 1,2 1-5 C

M05-1069 ISM 001A B

24 2

B MO O

D-5 1,2 1-5 C

M05-1069 ISM 001B B

24 2

B MO O

D-4 1,2 1-5 C

M05-1069 l

ISM 002A B

24 2

B MO O

D-5 1,2 1-5 C

M05-1069 ISM 002B B

24 2

B MO O

D-4 1,2 1-5 C

M05-1069 ISM 003A R

3/4 x 1 2

C 0

D/E-5 5

1-5 C

M05-1069 ISM 003B R

3/4 x 1 2

C O

D/E-4 5

1-5 0

M05-1069 ISM 008 EFC 3/4 2

C C

A/B-3/4 1

1-5 0

M05-1069 ISM 009 EFC 3/4 2

C C

C-3/4 1

1-5 o

M05-1069 ISM 010 EFC 3/4 2

C C

C/D-3/4 1

1-5 o

M05-1069 ISM 011 EFC 3/4 2

C C

B-3/4 1

1-5 C

M05-1052/1 ISX001A KC 30 3

C 0

D-7 1

1-5 C

M05-1052/2 ISX001B NC 30 3

C 0

D-7 1

1-5 C

M05-1052/3 ISX001C NC 10 3

C O

D-7 1

1-5 0

M05-1052/1 ISX003A B

30 3

B MO 0,C D-6 1,2 1-5 0

M05-1052/2 ISX003B B

30 3

B MO 0,C D-6 1,2 1-5 0

M05-1052/3 ISX003C B

10 3

B MO 0,C D-6 1,2 1-5 O

M05-1052/1 ISX004A B

30 3

B MO 0,C D-5 1,2 1-5

^

Revision 1 l

_ - ~ _ _.

POSITION 2

VALVE EORM P&ID TEST TEST 1

NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS i

O M05-1052/2 l

1SX004B B

30 3

B MO 0,C D-5 1,2 1-5 0

M05-1052/3 ISX004C B

10 3

B MO 0,C D-5 1,2 1-5 C

M05-1052/3 ISIOO6C B

8 3

B MO O

D-3 1,2 1-5 l

C M05-1052/1 ISX008A B

20 3

B MO O

E-6 1,2 1-5 C

M05-1052/2 I

ISX008B B

20 3

B MO O

E-6 1,2 1-5 C

M05-1052/3 ISXOOSC B

8 3

B MO O

D-6 1,2 1-5 C

M05-1052/1 See Relief ISX010A CV 2

3 B

AO O

E-3 1,7 1-5 Request 048 i

C M05-1052/2 See Relief ISX010B CV 2

3 B

AO O

E-3 1,7 1-5 Request 048 C

M05-1052/3 See Relief 1

ISX010C CV 1}

3 B

AO O

E-4 1,7 1-5 Request 048 I

C M05-1052/1 ISX011A B

16 3

B MO O

D-3 1,2 1-5 j

C M05-1052/1 1

ISX011B B

16 3

B MO O

E-3 1,2 1-5 C

M05-1052/1 See Relief ISX012A B

14 3

B MO O

C-3 1,2 5

Request 030 C

M05-1052/2 See Relief I

ISX012B B

14 3

B MO O

C-3/4 1,2 5

Request 030 l

C M05-1052/1 See Relief ISX013D P

3 3

B MO O

C-5 Request 049 i

C M05-1052/2 See Relief Request 049 ISX013E P

3 3

B MO O

D-5 C

M05-1052/3 See Relief l

Request 049 ISX013F P

2 3

B MO O

C-5 O

M05-1052/1

]

ISX014A B

20 3

B M0 C

F-3 1,2 1-5 0

M05-1052/2 l

{

ISX014B B

20 3

B MO C

F-3 1,2 1-5 0

M05-1052/3 ISX014C B

8 3

B MO C

E-4 1,2 1-5 C

M05-1052/1 See Relief ISX016A C

21 3

B MO O

C/D-3/4 1,2 5

Request 017 i

?

Revision 1 LJE51A }

1 i

POSITION 2

VALVE NORM P&TD TEST TEST y

NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1052/2 See Relief ISXOl6B C

2) 3 B

MO O

D-3/4 1,2 5

Request 017 0

M05-1052/1 i

l ISX017A B

8 3

B M0 O.C B-7 1,2 1-5 l

0 M05-1052/2 l

ISX017B B

8 3

B MO 0,C B-7 1,2 1-5 O

M05-1052/1 i

ISX019A CV 8

3 B

HO 0,C B-6 1,2 1-5 0

M05-1052/2 ISX019B CV 8

3 B

H0 0,C B-6 1,2 1-5 0

M05-1052/1 ISXO20A B

12 3

B MO 0,C C-4 1,2 1-5 O

M05-1052/2 ISIO203 B

12 3

B MO 0,C C-4 1,2 1-5 C

M05-1052/1 See Relief ISX023A CV 2

3 B

A0 O

C-2 1,7 1-5 Request 048 C

M65-1052/2 See Relief I

l ISIO23B CV 2

3 B

A0 0

C-2 1,7 1-5 Request 048 0

M05-1052/4 See Relief i

l 1SX025A CV 2

3 B

A0 0,C E-6 1,7 1-5 Request 048 O

M05-1052/4 See Relief ISX025B CV 2

3 B

A0 0,C E-2 1,7 1-5 Request 048 0

M05-1052/3 See Relief ISIO25C CV 1}

3 B

A0 0,C C-2 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX027A CV 2

3 B

A0 0

D-6 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISIO27B CV 21 3

B A0 0

D-2 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX027C CV 2{

3 B

A0 0

C-2 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX029A CV 11 3

B AO O

D-6 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX029B CV 1}

3 B

A0 0

D-2 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX029C CV 11 3

B A0 0

B-2 1,7 1-5 Request 048 C

M051052/4 See Relief ISXO33 CV 2

3 B

A0 O

C-6 1,7 1-5 Request 048 C

M05-1052/4 See Relief ISX037 CV 1) 3 B

A0 0

B-6 1,7 1-5 Request 048 LJESIA Revision 1

l POSITION 2

VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1052/3 See Relief ISX041A CV 2

3 B

AO O

C-2 1,7 1-5 Request 048 C

M05-1052/3 See Relief j

1SX041B CV 2

3 B

A0 0

B-2 1,7 1-5 Request 048 C

M05-1052/1 See Relief ISXO62A B

14 3

B MO O

B-4 1,2 5

Request 030 i

C M05-1052/2 See Relief ISX062B B

14 3

B MO O

B-4 1,2 5

Request 030 C

M05-10521 1SXO63A B

8 3

B MO O

C-2 1,2 1-5 C

M05-10521 ISX063B B

8 3

B MO O

C-2/3 1,2 1-5 C

M05-1052/5 See Relief ISIO71A G

3 3

B MO F-7 Request 050 C

M05-1052/5 See Relief ISIO71B G

3 3

B MO F-3 Request 050 C

M05-1052/5 See Relief l

ISX072A NC 3

3 C

E-7 Request 050 C

M05-1052/5 See Relief ISIO729 NC 3

3 C

E-3 Request 050 C

M05-1052/5 See Relief ISIO73A G

3 3

B MO F-6 Request 050 C

M05-1052/5 See Relief J

j ISX073B G

3 3

B MO F-2 Request 050 C

M05-1052/5 See Relief 3

ISIO74A C

3 3

B MO E-7 Request 050 C

M05-1052/5 See Relief ISX074B C

3 3

B MO E-3 Request 050 C

M05-1052/5 See Relief ISX075A NC 3

3 C

D-7 Request 050 C

M05-1052/5 See Relief l

1SXO75B NC 3

3 C

D-3 Request 050 C

M05-1052/5 See Relief 1

ISIO76A C

3 3

B MO D-7 Request 050 C

M05-1052/5 See Relief ISX076B G

3 3

B MO D-3 Request 050 O

M05-1052/1 ISX082A C

3 3

B MO 0,C D-1 1,2 1-5 0

M05-1052/2 ISX082B G

3 3

B MO 0,C D-1 1,2 1-5 Revision 1 LJESIA i

)

POSITION VALVE NORM P&ID TEST' TEST N1'MBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS O

M05-1052/1 ISX083A NC 3

3 C

C D-1 1

1-5 0

M05-1052/1 ISX083B NC 3

3 C

C D-1 1

1-5 0

M05-1052/5 ISX088A G

3 2

B MO C

C-8 1,2 1-5 O

M05-1052/5 ISX088B C

3 2

B MO C

C-4 1,2 1-5 O

M05-1052/5 ISX089A G

3 2

B MO C

C-7 1,2 1-5 O

M05-1052/5 i

1SXO89B C

3 2

B M0 C

C-3 1,2 1-5 l

C M05-1052/5 l

ASX095A G

2}

3 B

Mo '

O C-6 1,2 1-5 l

C M05-1052/5 ISX095B G

2) 3 B

MO O

C-2 1,2 1-5 O

M05-1052/5 ISX096A G

3 2

B M0 C

C-5/6 1,2 1-5 0

M05-1052/5 ISXO96B G

3 2

B M0 C

C-2 1,2 1-5 O

M05-1052/5 ISX097A G

3 2

B MO C

C-5 1,2 1-5 dev 1 O

M05-1052/5 ISX097B G

3 2

B M0 C

C-1 1,2 1-5 C

M05-1052/5 See Relief Request 050 ISX105A G

3 3

B MO D-7 C

M05-1052/5 See Relief Request 050 ISX105B C

3 3

B MO D-3 C

M05-1052/5 See Relief Request 050 ISX106A C

3 3

C D-7 C

M05-1052/5 See Relief Request 050 ISX106B C

3 3

C D-3 C

M05-1052/5 See Relief Request 050 ISX107A G

3 3

B MO D-7 C

M05-1052/5 See Relief ISX107B G

3 3

B MO D-3 Request 050 C

M05-1052/4 ISX149 R

3/4x1 3

C O

C/D-5/6 5

4,5 C

M05-1052/4 ISX150 R

3/4x1 3

C 0

B-6 5

4,5 Revision 1 LJE51A,

POSITION VALVE NORM P&ID TEST TEST y

NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1052/4 ISX151A R

3/4x1 3

C 0

E-5/6 5

4,5 C

M05-1052/4 C

0 E-2 5

4,5 ISX151B R

3/4x1 3_

C M05-1052/4 ISX151C R

3/4x1 3

C 0

C-2 5

4,5 C

M05-1052/1 ISX152A R

3/4x1 3

C 0

C-3 5

4,5 C

M05-1052/2 ISX152B R

3/4x1 3

C 0

C-2 5

4,5 C

M05-1052/1 ISX_153A R

3/4x1 3

C 0

B-6 5'

4,5 C

M05-1052/2 ISX153B R

3/4x1 3

C 0

B-6 5

- ' 4,5 C

M05-1052/4 1SX154A R

3/4x1 3

C 0

E-5 5

4,5 C

M05-1052/4 ISX154B R

3/4x1 3

C 0

E-2 5

4,5 C

M05-1052/3 ISX154C R

3/4x1 3

C 0

C-2 5

4,5 C

M05-1052/1 ISX155A R

3/4x1 3

C 0

E-4 5

4,5 C

M05-1052/2 ISX155B R

3/4x1 3

C 0

F-3/4 5

4,5 C

M05-1052/3 ISX155C R

3/4x1 3

C 0

D-4 5

4,5 C

M05-1052/3 ISX156A R

3/4x1 3

C 0

C-2 5

4,5 C

M05-1052/3 ISX156B R

3/4x1 3

C 0

B-2 5

4,5 C

M05-1052/5 ISX157A R

3/4x1 3

C 0

C-6 5

4,5 C

M05-1052/5 1

ISX157B R

3/4x1 3

C 0

C-2 5

4,5 C

M05-1052/1 ISX169A R

3/4x1 3

C 0

C-3 5

4,5 C

M05-1052/2 ISX169B R

3/4x1 3

C 0

C-3 5

4,5 C

M05-1052/3 l

1SX169C R

3/4x1 3

C 0

D-2 5

4,5 LJE51A Revision 1

POSITION VALVE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1052/1 0

B-3 5

4,5 ISX170A R

3/4x1 3

C C

M05-1052/2 0

B-3 5

4,5 ISX170B R

3/4x1 3

C C

M05-1052/1 ISX173A G

10 3

B MO O

D-2 1,2 1-5 C

M05-1052/2 ISX173B G

10 3

B MO O

D-2 1,2 1-5 C

M05-1052/1 See Relief ISX181A CV 2) 3 B

A0 0

F-1 1,7 1-5 Request 048 C

M05-1052/2 See Relief ISX181B CV 2) 3 B

A0 0

F-1 1,7 1-5 Request 048 C

M05-1052/1 See Relief ISX185A CV 2}

3 B

A0 0

E-1 1,7 1-5 Request 048 C

M05-1052/2 See Relief ISX185B CV 21 3

B A0 0

E-1 1,7 1-5 Request 048 C

M05-1052/2 See Relief ISX189 CV 2) 3 B

A0 0

B-4 1,7 1-5 Request 048 C

M05-1052/1 See Relief 1SX193A CV ll 3

B A0 0

B-7 1,7 1-5 Request 048 C

M05-1052/2 See Relief ISX193B CV ll 3

B A0 0

B-4 1,7 1-5 Request 048 C

M05-1052/1 See Relief ISX197 CV 2

3 E

AO O

B-4/5 1,7 1-5 Request 048 C

M05-1052/1 0

F-1 5

4,5 ISX200A R

3/4x1 3

C C

M05-1052/1 ISX200B R

3/4x1 3

C 0

F-1 5

4,5 C

M05-1052/1 ISX201A R

3/4x1 3

C 0

E-1 5

4,5 C

M05-1052/2 ISX201B R

3/4x1 3

C 0

E-1 5

4,5 C

M05-1052/2 ISX202A R

3/4x1 3

C 0

A-7 5

4,5 C

M05-1052/2 ISX202B R

3/4x1 3

C 0

C-4/5 5

4,5 C

M05-1052/2 ISX203 R

3/4x1 3

C 0

B-4/5 5

4,5 C

M05-1052/1 0

B/C-5 5

4,5 ISX204 R

3/4x1 3

C C

M05-1052/2 ISX207 R

3/4x1 3

C 0

B-2 5

4,5 LJE51A Revision 1

POSITION VALUE NORM P&ID TEST TEST NUMBER TYPE SIZE CLASS CATEGORY ACTUATOR TEST COORD METH COND COMMENTS C

M05-1052/1 ISX208A R

4x6 3

C 0

D-1 5

4,5 C

M05-1052/2 ISX208B R

4x6 3

C 0

D-1 5

4,5 C

M05-1052/2 See Relief ISX209 CV 1}

3 B

AO O

A-1 1,7 1-5 Request 048 C

M05-1052/1 ISX294 R

3/4x1 3

C 0

D-7 5

4,5 C

M05-1052/1 See Relief C-8 Request 051 2SX017A B

8 3

B MO C

M05-1052/2 See Relief 2SX017B B

8 3

B MO C-8 Request 051 C

M05-1052/5 See Relief 2SX073A G

3 3

B MO E-7 Request 051 C

M05-1052/5 See Relief 2SX073B G

3 3

B MO E-3 Request 051 C

M05-1052/5 See Relief 2SX076A G

3 3

B MO E-7 Request 051 C

M05-1052/5 See Relief 2SX076B G

3 3

B MO E-3 Request 051 C

M05-1052/5 See Relief 2SX107A G

3 3

B MO D-7 Request 051 C

M05-1052/5 See Relief 2SX107B G

3 3

B MO D-3 Request 051 C

M05-1102/1 See Relief OVC056A GL 2.5 3

B SO O

E-5 1

1-5 Request 055 C

M05-1102/1 See Relief OVC056B GL 2.5 3

B SO O

B-5 1

1-5 Request 055 C

M05-1102/1 See Relief Sev 1 OVC057A GL 2.5 3

B SO O

E-5 1

1-5 Request 055 C

M05-1102/1 See Relief OVC057B GL 2.5 3

B SO O

B-5 1

1-5 Request 055 C

M05-1102/1 See Relief OVC058A GL 2.5 3

B SO O

D-3 1

1-5 Request 055 C

M05-1102/1 See Relief OVC058B GL 2.5 3

B SO O

B-3 1

1-5 Request 055 LJE51A Revision 1

5 5

S f5 f5 T

e0 e0 N

i i

E l t l t M es es M R e R e O

u u

C eq eq ee ee SR SR 1

n 5

5 5,

5, o

TD 5

5 5

5 5

5 5

5 5

5 5

5 SN i

EO 1

1 1

1 1

1 1

1 1

1 1

1 4

4 4

4 s

TC ive R

2 TH 2,

2, 2,

2, 2,

2, 2,

2, ST 1

1 1

1 5

5 5

5 EE 1

1 1

1 1

1 1

1 TM 0

1 1

4 1

2 3

2 3

2 3

2 3

2 3

2 3

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

2 2

5 5

9 9

9 9

9 9

9 9

9 9

9 9

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

D 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 DR IO 53 53 0

0 53 53 52 52 53 53 52 52 53 53 53 53

&O 0 -

0 -

1 1

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

PC MD MB M

M MD MD MD MD ME ME ME ME MD MD MF MF T

N S

O E

I T

O O

0 0

C C

C C

C C

C C

0 0

0 0

T I

S 7

O M 5

P R

C C

C C

0 0

0 0

0 0

0 0

C C

C C

ON ROTA O

O 0

0 0

0 O

O 0

0 U

S S

M M

M M

M M

M M

TCA YRO G

B B

C C

B B

B B

B B

B B

C C

C C

ETAC S

SA 3

3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 LC l

1 1

l 5

4 4

x x

x x

E 5

Z

/

/

0 0

0 0

0 0

0 0

4 4

4 4

I 2

2 3

3 1

1 1

1 1

1 1

1

/

/

/

/

S 3

3 3

3 E

C C

P L

L F

F G

G G

G G

G G

G R

R R

R Y

G G

E E

T ER A

B B

B A

B A

B A

B A

B A

B A

B VE 9

9 6

7 4

4 5

5 4

4 5

5 3

3 7

7 A

LB 5

5 5

5 0

0 0

0 1

1 1

1 2

2 2

2 1

AM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 5

VU C

C G

G P

P P

P P

P P

P P

P P

P E

N V

V V

V V

V V

V V

V V

V V

V V

V J

O O

I I

I I

I I

I I

I I

I I

I I

L 1

ve R

STNEM M

O C

1 no is i

TD 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

v SN e

EO 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

R TC 7,

7, 7,

7, 7,

7, 7,

7, 7,

7, 7,

7, 7,

2, 2,

2, 2,

TH ST 2,

2, 2,

2, 2,

2, 2,

2, 2,

2, 2,

2, 2,

1 1

1 1

1 1

EE 1

1 1

1 1

1 1

1 1

1 1

1 1

TM 2

2 2

2 2

2 2

2 2

1 1

1 1

5 5

5 5

5 5

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

0 0

0 0

0 0

0 0

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 D

1 1

1 1 6 1 4 1 5 16 1

15 1

1 1

1 1

1 1

1 1

1 DR

/

/

I O 58 57 56 55 5D 5D 5D 54 54 52 51 52 51 53 52 57 57 0

0

&O 0 -

0 -

0 -

0 -

0/

0/

0/

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

0 -

1 1

PC MC MC MC MC MC MC MC MC MC ME ME ME ME ME ME MB MB M

M y

T C,

C, C,

C, C,

C, C,

C, C,

C, C,

C, C,

N S

O E

I T

0 0

0 0

0 0

0 0

0 0

0 0

0 C

C C

C C

C T

I 8

S 5

O M PR C

C C

C C

C C

C C

C C

C C

0 0

0 0

0 0

O N

ROTA 0

0 0

0 O

0 0

O O

0 0

O O

0 0

0 0

U A

A A

A A

A A

M M

A A

M M

A A

A A

TCA YROG B

B B

B B

B B

B B

B B

B B

B B

B B

C C

ETAC S

SA 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

LC E

4 4

Z 4

4 4

6 6

6 0

4 4

6 6

4 4

2 2

2 2

/

/

I 2

2 2

3 3

3 1

3 3

1 1

1 1

3 3

S E

C C

P B

B B

B B

B B

L L

B B

L L

B B

B B

F F

Y C

C G

G E

E T

ER A

B A

B A

B A

B A

B A

B A

B A

B VE 1

1 2

3 4

4 5

6 6

1 1

2 2

6 6

7 7

6 6

A LB 0

0 0

0 0

0 0

0 O

0 0

0 0

0 0

0 0

1 1

1 AM 0

0 0

0 0

0 0

0 O

0 0

0 0

0 0

0 0

0 0

5 VU Q

Q Q

Q Q

Q Q

Q Q

R R

R R

R R

R R

R R

E N

V V

V V

V V

V V

V V

V V

V V

V V

V V

V J

I I

I I

I I

I I

I I

I I

I I

I I

I I

I L

POSITION 2

VALVE NORM P&ID TEST TEST g

NUMBER TYPE SIZE CLASS CATECORY ACTUATOR TEST COORD METH COND COMMENTS 0

IVR018A EFC 3/4 2

C C

M10-1111/5 1

1-5 0

1VR018B EFC 3/4 2

C C

M10-1111/5 1

1-5 0

See Relief IVR035 2 way 3/4 2

B SO C

M10-1111/19 1,7 1-5 Request 035 0

See Relief IVRO36 2 way 3/4 2

B So C

M10-1111/19 1,7 1-5 Request 035 0

See Relief IVR040 2 way 3/4 2

B SO C

M10-1111/19 1,7 l-5 Request 035 0

See Relief IVR041 2 way 3/4 2

B SO C

M10-1111/19 1,7 1-5 Request 035 0

M05-1117/9 See Relief 1W0001A G

6 2

B M0 C

E-5 1,2 5

Request 021 0

M05-1117/9 See Relief 1W0001B G

6 2

B M0 C

E-6 1,2 5

Request 021 0

M05-1117/9 See Relief 1W0002A G

6 2

B M0 C

F-5 1,2 5

Request 021 0

M05-1117/9 See Relief IWOOO2B G

6 2

B MO C

F-6 1,2 5

Request 021 0

M05-1117/26 See Relief 1WO55LA G

4 2

B M0 C

E-7 1,2 5

Request 052 0

M05-1117/26 See Relief 1WO 55 '.B G

4 2

B M0 C

E-7 1,2 5

Request 052 0

M05-1117/26 See Relief 1WO552A G

4 2

B M0 C

D-7 1,2 5

Request 052 0

M05-1117/26 See Relief 1WO552B G

4 2

E M0 C

D-7 1,2 5

Request 052 C

M05-1117/26 IWO570A R

3/4x1 2

C 0

E-7 5

4,5 C

M05-1117/26 IWO570B R

3/4x1 2

C 0

D-7 5

4,5 0,C M05-1089/2 IWX019 P

2 2

B A0 C

E/F-6 1,2,7 1-5 0,C M05-1089/2 IWX020 P

2 2

B A0 C

E/F-5 1,2,7 1-5 Revision 1 LJE51A RELIEF REQUEST 003 I.

Component Identification:

A.

Name:

Vacuum Relief Valves B.

Number:

1B21F037A-H,J-N,P,R,S, 1B21F078A-H,J-N,P,R,S 1B21F379A-H,J-N,P,Q,R, AND 1B21-F040 C.

Function:

Prevent drawing vacuum in safety relief valve discharge and vent lines following relief valve operation D.

ASME Section III Code Class:

3 E.

ASME Section XI Valve Category:

C II.

Relief from:

A.

ASME Code Requirement:

IUC-3520 Exercise valve every three (3) months.

B.

Reason for Relief:

Valves are located inside the drywell and are inaccessible during normal plant operations C.

Alternate In-Service Test:

Exercise valves for operability during refueling outages.

LJE51 Revision 1 l

RELIEF REQUEST 005 I.

Component Identification:

A.

Name:

Main Steam Line Isolation Valves 1

B.

Number:

IB21-F098A,B,C,D C.

Function:

Isolation Main Steam Lines from the Turbine Building D.

ASME Section III Code Class:

2 i

E.

ASME Section XI Valve Category:

B i

II.

Relief from:

t A.

ASME Code Requirement:

IWV-3410 Exercise and stroke time valve every three (3) months.

2 B.

Reason for Relief:

Valve cannot be exercised during normal i

plant operation without curtailing flow to the main turbine and affecting plant operations i

C.

Alternate In-Service-Test:

Exercise and stroke time valve Rev 1 for operability during refueling outages.

4 4

i i

I LJE51 Revision 1

.... - - -. ~ ~, -..,. -,

mr

_s,,-J

m RELIEF REQUEST 010 I.

Component Identification:

A.

Name:

CRD Drive Water Header Check Valve B.

Number:

ICll-F122 C.

Function:

Containment Isolation and prevent back flow to reactor water when CRD pumps-are secured.

D.

ASME Section III Code Class:

2 E.

ASME Section XI Valve Category:

C II.

Relief from:

A.

ASME Code Requirement:

IWV-3520 Exercise valve every three (3) months.

B.

Reason for Relief:

Testing this valve requires that the CRD system be shutdown, thus rendering rod motion inoperative and stopping seal flow to the recirculation pumps.

C.

Alternate In-Service Test:

Operability of valve shall be confirmed during local leak rate testing (normally open valve).

i

' ll LJE51. Revision 1 l

I

RELIEF REQUEST 032 1.-

Component Identification:

A.

Name:

Containment Monitoring Containment Isolation Valves o

B.

Number:

See Table 32-1 C.

Function:

Isolate the containment monitoring system from the containment D.

ASME Section III Code Class:

2 E.

ASME Section XI Valve Category:

B 4

II.

Relief from:

A.

ASME Code Requirement:

IWV-3410 Valve Exercising and stroke time test B.

Reason for Relief:

These valves perform #only a containment isolation function and do not serve as a reactor coolant boundary.

The speed at which these air operated valves close does not influence the mitigation of an accident.

l C.

Alternate In-Service Test:

NONE (Valve position will be verified during the normal performance of containment i

isolation surveillance requirements.)

1 LJE51 Revision 1

7..

RELIEF REQUEST 036 I.

Component Identification:

A.

Name:

Reactor Recire. Pumps A & B Seal / Oil Cooling Inlet and Outlet Valves B.

Number:

ICC065, ICC067, ICC068, ICC070, ICC188A, ICC188B C.

Function:

Supply cooling water to reactor recire. pumps D.

ASME Section III Code Class:

2 E.

ASME Section XI Valve Category:

B&C II.

Relief from:

A.

ASME Code Requirement:

IWV-3410 and IWV-3520 valve exercising and stroke timing test.

B.

Reason for Relief:

These valves are normally open during plant operation.

Exercising these valves would eliminate cooling water to Reactor Recirc Pumps.

C.

Alternate In-Service Test:

Exercise and stroke time test these valves during refueling outages.

LJE51 Revision 1 1

e RELIEF REQUEST 041 I.

Component Identification:

A.

Name:

Supply Line Check Valve B.

Number:

lE21-F306 C.

Function:

Cycled Condensate Flushing Supply Line D.

ASME Section III Code Class:

2 E.

ASME Section XI Valve Category:

C II.

Relief from:

A.

ASME Code Requirement:

IWV-3520 Valve Exercise Test B.

Reason for Relief: Exercising this valve will require low pressure core spray system to be inoperable.

C.

Alternate In-Service Test:

Exercise this valve during refueling outages.

LJE51

-102-Revision 1

RELIEF REQUEST 044 1.

Component Identification:

A.

Name:

Emergency Air Bottles Control Valves & Backup Air Rev 1 Bottles Control Valves (to SRV's)

Rnv 1 B.

Number:

1RA017A, 1RA017B, & IIA 044A, lIA044B C.

Function:

Supply Emergency Air to Various Manifolds Rev 1

& to SRV's D.

ASME Section III Code Class:

3 E.

ASME Section XI Valve Category:

B II.

Relief from:

A.

ASME Code Requirement:

IWV-3410 Valve Exercising and Stroke Time Test B.

Reason for Relief: These control valves are normally open during plant operation.

These are installed to control the air flow from emergency air bottles and cannot be exercised.

C.

Alternate In-Service Test:

- None -

LJE51

-107-Revision 1

r RELIEF REQUEST 050 I.

Component Identification:

A.

Name:

Manual Deluge Valves B.

Number:

See Table 50-1 C.

Function: Provide Shutdown Service Water to SGBT Charcoal Beds, Makeup Air Filter-Package, Air Filter Package D.

ASME Section III Code Class:

3 E.

ASME Section XI Valve Category:

B&C II.

Relief from:

A.

ASME Code Requirement: IWV-3410, IUV-3520 Valve Exercising and Stroke Time Test B.

Reason for Relief: These systems are not designed to perform any surveillance testing.

The proper operation of these valves is not required to mitigate the consequences of an accident or to keep reactor in cold shutdown.

C.

Alternate In-Service Test:

- None i

i l

l LJE51

-114-Revision 1

,_. ~

r RELIEF REQUEST 054 I.

Component Identification:

A.

Name:

Pressure Isolation Valves l

B.

Number: 1E21-F005, 1E21-F006, 1E12-F041A, IE12-F041B, 1E12-F0410, lE12-F042A, lE12-F042B, lE12-F042C, IE12-F050A, Rev 1 1E12-F050B, lE12-F053A, lE12-F053B, 1E12-F009, lE12-F008, 1E12-F023, lE51-F066, lE51-F013, lE22-F004, 1E22-F005 C.

Function: Provide Isolation Between Reactor Coolant System and Low Pressure Systems D.

ASME Section III Code Class:

1,2 E.

ASME Section XI Valve Category:

A, B, C II.

Relief from:

A.

ASME Code Requirement: IWV-3410, IWV-3520 Valve exercising and stroke timing test.

B.

Reason for Relief: Exercising these valves during plant operation may cause inter-system LOCA.

C.

Alternate In-Service Test: Exercise and stroke time these valves during refueling outages.

LJE51

-119-Revision 1

G j

~ #

RELIEF REQUEST 055 I.

Component Identification:

A.

Name:

Control Room HVAC Supply Air & Makeup Air Filter Package

\\

B.

Number: OVC056A, 0VC056B, 0VC057A, 0VC057B, 0VC058A, OVC058B, 0VC059A, 0VC059B

+

C.

Function: Isolate between Control Room HVAC (VC) System and Turbine Building Equipment Drain System

~

D.

ASME Section III Code Class:

3 E.

ASME Section XI Valve Category:

B II.

Relief from:

A.

ASME Code Requirement: IWV-3410 Valve exercising and stroke j

Time Test.

B.

Reason for Relief:

These valves are normally closed.

These valves are 2.5 inch solenoid operated valves and timing them is not practical due to their rapid movement.

C.

Alternate In-Service Test:

Fully stroke valves every three months LJ551

-120-Revision 1