_ -

-. - -.

.

.... - - - - -

.

,

_o

..

DOCUMENT CONTAINS

' ~

APPENDIX U.S. NUCLEAR REGULATORY COMMISSION l

REGION IV

%.

'

Inspection Report:

50-445/93-09 50-446/93-09

i Operating Licenses:

NPF-87

,

Construction Permit:

CPPR-127

,

Licensee: TU Electric Skyway Tower-

'

400 North Olive Street, L.B. 81-

-

Dallas, Texas 75201 Facility Name: Comanche.Penk Steam Electric Station, Units 1 & 2

,

-

Inspection At: Glen Rose,~ Texas i

l Inspection Conducted: January 18, 1993

,

Inspector:

A. B. Earnest, Physical Security Specialist

i Facilities Inspection Programs Section

!

Approved:

Ald i M//l d/

b

Blaine Murray, Chief, Jacyties Inspection Date'

i Programs Section Inspection Summar_y Areas Inspected (Unit 11: No inspection of Unit 1 activities was performed.

Areas Inspected (Unit 21: Routine, announced preoperational inspection of the

'

licensee's Unit _2 physical security program. _The_ areas inspected within the

_ Unit-2 physical security-program included records and reports,_ lock and key

control, emergency power-supply, compensatory measures, access control- -

.

+

personnel, alarm stations, communications, and safeguards contingency plan-

'

implementation review.

'

ENCLOSURE CONTAINS

.

.

'

DOCUMENT CONTAINS UPON SEPARATION THIS-PAGE IS DECONTROLLED.

9302100384 930204

'

-

PDR ADOCK 05000445

'

O FDR.

,

-

.

-.

.

--.. - -.-

~.,-....- -.

..

~..

.. -.

. -

.

.--.---.7.-.-

.

.

-2-DOCUMENT CONTAINS SAFEGUARDS IFFORMATION Pesults (Unit 1): Not applicable.

_;

Results (Unit 2):-

,

An' excellent records and reports system had been established. Required

  • -

reporting was completed within the correct time. frames (Section 1.2).

-

.i A very good lock and key control system had been established e

i (Section 2.2).

-The test of the emergency power supply indicated that the' system

performed _well (Section 3.2).

- The compensatory measures program was efficiently implemented. The

[

security officers were well trained on the program requirements

(Section 4.2).

The access control equipment.was adequate to' ensure that personnel and

hand-carried packages were adequately searched (Section 5.2).

The alarm stations were redundant and well protected, and the operators

were alert and well trained (Section 6.2).

A good communications system had been established to meet security

requirements (Section 7.2).

The safeguards' contingency program was effective in ensuring that

threats to the security of the plant would be neutralized (Section 8.2).

Attachment:

Attachment - Persons Contacted and Exit Meeting

i'

,

i ENCLOSURE CONTAINS

!.

. DOCUMENT CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED.

,

- _ _. _

.

.

...

.

...

...

.