__

May 10,1985 Dockets Nos. 50-321 DISTRIBUTION and 50-366 6

JPartlow NRC PDR ACRS-10 L PDR RIngram ORB #4 Rdg GRivenbark Mr. J. T. Beckham, Jr.

HThompson Gray File Vice President - Nuclear Generation OELD EJordan Georgia Power Company BGrimes JPage P. O. Box 4545 Atlanta, Georgia 30302

Dear Mr. Beckham:

We have completed our review of your April 4,1985 request for relief from the American Society of Mechanical EngineersSection XI Code with respect to leak testing the Hatch Unit 1 and 2 Main Steam Isolation Valves. As indicated in the enclosed Safety Evaluation, we grant the requested relief.

We have determined pursuant to 10 CFR Part 50.55a(g)(6)(i), that the granting of this relief is authorized by law and will not endanger life or property or the common defense and security and is othentise in the public interest.

In making this determination, we have given due consideration to the burden that could result if these requirements were imposed on your facility.

Sincerely,

."ELG1SiiL sic;w yy EU F. 570%s./

John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page r

ll.9 ORB #4:0 -

ORB

DL 0

ML QEl.

RIngram GRi nbark;cr J

^*I 5/h/85 5/(/85 5/ /8 5/rl/85 8505280100 050510 PDR ADOCK 05000321 P

PDR

Hatch 1/2 50-321 and 50-366 Georgia Power Company ccw/ enclosure (s):

G. F. Trowbridge, Esq.

Regional Radiation Representative Shaw, Pittman, Potts and Trowbridge EPA Region IV 1800 M Street, N. W.

345 Courtland Street. M. E.

Washington, D. C.

20036 Atlanta, Georgia 30308 Ruble A. Thomas Resident Inspector Vice President U. S. Nuclear Regulatory Comission P. O. Box 2625 Route 1, P. O. Box 279 Southern Company Services, Inc.

Baxley, Georgia 31513 Birmingham, Alabama 35202 Dr. J. Nelson Grace, Regional Louis B. Long Administrator Southern Company Services, Inc.

U. S. Nuclear Regulatory Commission P. O. Pox 2625 Region II Birmingham, Alabama 35202 101 Marietta Street, Suite 2900 Atlanta, Georgia 30303 Chairman Appling County Commissioners County Courthouse Charles H. Badger Raxley, Georgia 31513 Office of Planning and Rudget Room 610 270 Washington Street, S. W.

Mr. L. T. Gucwa Atlanta, Georgia 30334 Georgia Power Company Engineering Department

0. Box 4545 J. Leonard Ledbetter, Comissioner Atlanta, Georgia 30302 Department of Natural Resources 270 Washington Street, N. W.

Atlanta, Georgia 30334 Mr. H. C. Nix,ilr. General Manager Edwin I. Hatch Nuclear Plant Georgia Power Company P. 0. Box 442 Baxley, Georgia 31513 l