ML20113E864

From kanterella
Jump to navigation Jump to search
CY-BY-170-301, Revision 15, Offsite Dose Calculation Manual. (Part 2 of 3)
ML20113E864
Person / Time
Site: Byron  
(NPF-037, NPF-066)
Issue date: 02/28/2019
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20113E860 List:
References
BYRON 2020-0026 CY-BY-170-301, Rev 15
Download: ML20113E864 (95)


Text

CY-BY-170-301 Revision 15 Page 94 of 188

3.

To comply with this specification, the effluent radiation monitor has a setpoint corresponding to an offsite total body dose rate at or below the limit (see Part 2 Section 2.6). In addition, compliance is assessed by calculating offsite total body dose rate based on periodic samples obtained per station procedures.

4.2.1.2 Noble Gas: Skin Dose Rate

1.

ODCM Part 1 limits the skin dose rate due to noble gases in gaseous effluents released from a site to areas at and beyond the site boundary to less than or equal to a dose rate of 3000 mrem/yr at all times. (See TRM 3.11.f)

2.

The skin dose rate due to noble gases released in gaseous effluents is calculated by the following expression:

DsK = r{L.[(x/Q).Q ** +(x/Q)vQlv +(x/Q)gQlg]

(4-2)

I

+ (1.11) Ml [ (x/Q)~Qls +(x/Q)~Qlv +(x/Q)~Qlg]}

The summation is over noble gas radionuclides i.

DsK Skin Dose Rate [mrem/yr]

Dose rate to skin due to beta and gamma radiation from noble gas radionuclides released in gaseous effluents.

L1 Skin Dose Conversion Factor [(mrem/yr)/(µCi/m3)]

Skin dose factor due to gamma emissions for noble gas radionuclide i. L values are taken from Table 4-28 M1 Gamma Air Dose Conversion Factor [(mrad/yr)/( µCi/m3)]

3.

Gamma air dose rate factor per unit of radioactivity release rate for radionuclide i.

See Table 4-28 for Gamma Air Dose conversion factors (From Table B-1 of Regulatory Guide 1.109).

4.

Since Byron does not have an elevated release point, the Ois term is not used.

CY-BY-170-301 Revision 15 Page 95 of 188

5.

To comply with this specification, gaseous effluent radiation monitors have setpoints corresponding to an offsite skin dose rate at or below the limit (see Part 2 Section 2.6). In addition, compliance is assessed by calculating offsite skin dose rate based on periodic samples obtained per station procedures.

4.2.1.3 Non-Noble Gas Radionuclides: Organ Dose Rate

1.

ODCM Part 1 limits the dose rate to any organ, due to radioactive materials in gaseous effluents released from a site to areas at and beyond the site boundary, to less than or equal to a dose rate of 1500 mrem/yr (See TRM 3.11.f)

2.

Typically the child is considered to be the limiting receptor in calculating dose rate to organs due to inhalation of non-noble gas radionuclides in gaseous effluents.

3.

The dose rate to any child organ due to inhalation is calculated by the following expression:

(4-3)

The summation is over non-noble gas radionuclides i.

  • NNG D(Chlld)l(lnhal)J Inhalation Dose Rate [mrem/yr]

Dose rate to the child age group from radionuclide i, via the inhalation pathway to organ j due to non-noble gas radionuclides.

R(Chlld)i(lnhal)j Inhalation Dose Factor [(mrem/yr)/(µCi/m3)]

Inhalation dose factor for child age group for radionuclide i, and organ j. Inhalation dose factors for non-noble gas radionuclides (child) are shown in Table 4-11

CY-BY-170-301 Revision 15 Page 96 of 188

4.

Since Byron does not have an elevated release point, the Ois term is not used.

5.

ODCM Part 1 requires the dose rate due to non-noble gas radioactive materials in airborne effluents be determined to be within the above limit in accordance with a sampling and analysis program specified in TRM Table T3.11.f-1.

6.

The child organ dose rate due to inhalation is calculated in each sector at the location of the highest offsite 1/Q (see Table 4-1 ). The result for the sector with the highest organ inhalation dose rate is compared to the limit.

4.2.2.

Time Averaged Dose from Noble Gas 4.2.2.1 Gamma Air Dose 1.

ODCM and TRM limits the gamma air dose due to noble gas effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:

A.

Less than or equal to 5 mrad per calendar quarter.

B.

Less than or equal to 10 mrad per calendar year.

The gamma air dose due to noble gases released in gaseous effluents is calculated by the following expression:

D, = (3.17E-8)LM1{ (x/Q)!A,s +(x/Q)!A 1v +(x/QnA 19 }

(4-4)

I The summation is over noble gas radionuclides i.

D, Gamma Air Dose [mrad]

Dose to air due to gamma radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years)............... [yr/sec]

M1 Gamma Air Dose Conversion Factor [(mrad/yr)/(µCi/m3)]

CY-BY-170-301 Revision 15 Page 97 of 188 Gamma air dose rate factor per unit of radioactivity release rate for radionuclide i. See Table 4-28 for Gamma Air Dose conversion factors (From Table 8-1 of Regulatory Guide 1.109).

(x/Q)!' (x/Q)!' (x/Q);

Gamma-x/Q Factor [sec/m3]

Radioactivity concentration based on finite cloud methodology at a specific location per unit of radioactivity release rate from a stack, vent or ground level release, respectively. See Table 4-3 for Gamma-x/Q Factors.

Cumulative Radionuclide Release [µCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the Ais term is not used.

2.

TRM 3.11.g requires determination of cumulative and projected gamma air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.

3.

Gamma air dose is calculated for the sector with the highest offsite (x/Q)Y and is compared with the Part 1 limits on gamma air dose.

4.

For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

4.2.2.2 Beta Air Dose

1.

TRM Chapter 3.11 limits beta air dose due to noble gases in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:

A.

Less than or equal to 10 mrad per calendar quarter.

B.

Less than or equal to 20 mrad per calendar year.

CY-BY-170-301 Revision 15 Page 98 of 188

2.

The beta air dose due to noble gases released in gaseous effluents is calculated by the following expression:

The summation is over noble gas radionuclides i.

D13 Beta Dose [mrad]

Dose to air due to beta radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years)

[yr/sec)

Ni Beta Air Dose Conversion Factor [(mrad/yr)/(µCi/m3)]

Beta air dose rate per unit of radioactivity concentration for radionuclide i.

See Table 4-28 for Beta Air Dose conversion factors (From Table B-1 of Regulatory Guide 1.109).

(x/Q)s (x/Q)v (x/Q)g Relative Concentration Factor [sec/m3]

Radioactivity concentration based on semi-infinite cloud methodology at a specified location per unit of radioactivity release rate for a stack, vent, or ground level release, respectively. See Table 4-1.

Cumulative Radionuclide Release [µCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the Ais term is not used.

CY-BY-170-301 Revision 15 Page 99 of 188

3.

TRM 3.11.g requires determination of cumulative and projected beta air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.

4.

Beta air dose is calculated for the sector with the highest offsite (x/Q) and is compared with the ODCM Part 1 limit on beta air dose.

5.

For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

4.2.2.3 Whole Body Dose

1.

The total body dose, to any receiver is due, in part, to gamma radiation emitted from radioactivity in airborne effluents. This component is added to others to demonstrate compliance to the requirements of 40CFR 190 and 1 OCFR20.

2.

The total body dose component due to gamma radiation from noble gases released in gaseous effluents is calculated by the following expression:

Dre =(3.17E-8)LK1{(x/O)!A 11 +(x/O)!A 1v +(x/Q)~A 19 }

{4-6)

I The summation is over noble gas radionuclides i.

Dre Total Body Dose [mrem]

Dose to the total body due to gamma radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years) [yr/sec]

K1 Gamma Total Body Dose Conversion Factor [(mrem/yr)/(µCi/m3)]

Gamma total body dose factor due to gamma emissions for noble gas radionuclide i released from a stack, vent or ground level release point, respectively. See Table 4-28 for Gamma total body dose conversion factors.

(From Table 8-1 of Regulatory Guide 1.109)

Cumulative Radionuclide Release [µCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

CY-BY-170-301 Revision 15 Page 100 of 188

3.

The total body dose is also calculated for the 40CFR190 and 10CFR20 compliance assessments. In some cases, the total body dose may be required in 10CFR50 Appendix I assessments (See Part 2 Table 1-1).

4.2.2.4 Skin Dose

1.

There is no regulatory requirement to evaluate skin dose. However, this component is evaluated for reference as there is skin dose design objective contained in 1 OCFR50 Appendix I. Note that in the unlikely event that beta air dose guideline is exceeded, then the skin dose will require evaluation.

2.

The part of skin dose due to noble gases released in gaseous effluents is calculated by the following expression:

The summation is over noble gas radionuclides i.

DsK Skin Dose [mrem]

Dose to the skin due to beta and gamma radiation from noble gas radionuclides released in gaseous effluents.

Beta Skin Dose Conversion Factor

[(mrem/yr)/(µCi/m3)]

Beta skin dose rate per unit of radioactivity concentration for radionuclide i. Taken from Table 4-28.

1.11 Conversion Constant (rads in air to rem in tissue) [mrem/mrad]

All other terms have been previously defined.

The skin dose is calculated for reference only.

4.2.3.

1.

Time Averaged Dose from Non-Noble Gas Radionuclides CY-BY-170-301 Revision 15 Page 101 of 188 TRM 3.11 provides the following limits, based on 1 OCFR50 Appendix I, on the dose to a member of the public from specified non-noble gas radionuclides in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary:

A.

Less than or equal to 7.5 mrem to any organ during any calendar quarter B.

Less than or equal to 15 mrem to any organ during any calendar year

2.

The individual dose components are also required as part of the 40CFR190 assessments and combined as part of the 1 OCFR20 assessment (Part 2 Table 1-1 ). The dose due to radionuclides deposited on the ground is considered to be a component of the deep dose equivalent for 1 OCFR20 compliance and an organ (and total body) dose component for 10CFR50 Appendix I and 40CFR190 compliance.

3.

The dose is calculated for releases in the time period under consideration.

CY-BY-170-301 Revision 15 Page 102 of 188

4.

Specifically, the dose is calculated as follows:

o:rG = (3.17E-8)LL[W.R 11P1A1* + WvRa1p1A1v + W9R11P1A 19 ]

(4-8) p I

The summation is over pathways p and non-noble gas radionuclides i.

o:rG Dose Due to Non-Noble Gas Radionuclides [mrem]

3.17E-8 Ws, Wv, W9 Dose due to non-noble gases (radioiodines, tritium and particulates) to age group a, and to organ j.

Conversion Constant (seconds to years) (yr/sec)

Relative Concentration Factor Radioactive concentration at a specific location per unit of radioactivity release rate or concentration for stack, vent or ground level release, respectively.

Ws, Wv, or W9 = (x/O)s, (x/O)v or (x/0)9 for immersion, inhalation and all tritium pathways.

W5, Wv, or W9 = (D/O)s, (D/O)v or (D/Q)9 for ground plain and all ingestion pathways.

(x/Q)s, (1/0)v, (1/0)g Relative Concentration Factor [sec/m3]

Radioactivity concentration based on semi-infinite cloud model at a specified location per unit of radioactivity release rate for a stack, vent, or ground level release, respectively. See Table 4-1 through Table 4-6.

(D/Q)s, (D/Q)v, (D/Q)g Relative Deposition Factor [1/m2]

Radioactivity concentration at a specified location per unit of radioactivity release concentration for a stack, vent, or ground level release, respectively. See Table 4-1 through Table 4-6.

Ra1pJ Site-Specific Dose Factor [(m2 mrem/yr)/(µCi/sec)]

or

[(mrem/yr)/(µCi/m3)]

CY-BY-170-301 Revision 15 Page 103 of 188 Site-specific dose factor for age group a, nuclide i, pathway p and organ j. Pathways included are ground plane exposure, inhalation, vegetation ingestion, milk ingestion and meat ingestion. Values of Raipj are provided in Table 4-7 and Table 4-9 through Table 4-26.

A1s, A1v, A19 Cumulative Radionuclide Release [µCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the stack terms for A1s, Ws, (x/Q)5,

and (D/Q)s are not used.

5.

TRM 3.11.h requires cumulative and projected dose contributions for the current calendar quarter and the current calendar year for the specified non-noble gas radionuclides in airborne effluents to be determined at least once per 31 days.

6.

To comply with this specification, Byron Station obtains and analyzes samples in accordance with the radioactive gaseous waste or gaseous effluent sampling and analysis program (TRM 3.11.f-1 ). In accordance with NU REG 0133 (Reference 14), dose due to non-noble gases is assessed at the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposure. The inhalation and ground plane exposure pathways are considered to exist at all locations. The food ingestion pathways at a specific location are considered based on their existence as determined by land use census. The values used for (x/Q) and (D/Q) are shown in Table 4-1 through Table 4-6 and correspond to the applicable pathway location.

7.

For a release attributable to a processing or effluent system shared by more than one reactor, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

8.

The dose evaluated is also included as part of the 10CFR20 and 40CFR190 assessment (See Part 2 Section 5).

4.2.3.1 Ground Plane CY-BY-170-301 Revision 15 Page 104 of 188

1.

The site-specific dose factor for ground deposition of radioactivity is considered to be a total body dose component and is calculated by the following expression:

Ra1(GP)1[D/Q]= K'K"(0.7)DFG{ 1- ~~>.itb]

(4-9)

Rai(GP)J[D/Q]

Ground Plane Deposition Dose Factor [(m2 mrem/yr)/(µCi/sec)]

Site-specific ground plane dose factor for age group a, nuclide i and organ j. The ground plane dose is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per µCi) [pCi/µCi]

K" Conversion Constant (8760 hr/yr) [hr/yr]

0.7 Shielding Factor; a factor that accounts for dimensionless shielding due to occupancy of structures.

DFG1 Ground Plane Dose Conversion Factor [(mrem/hr)/(pCi/m2)]

Dose rate to the total body per unit of surface radioactivity concentration due to standing on ground uniformly contaminated with radionuclide i. Ground Plane Dose Conversion Factors are shown in Table 4-8.

Note that ground plane dose conversion factors are only given for the total body and no age group. Doses to other organs are assumed to be equal to the total body dose. All age groups are assumed to receive the same dose.

1..1 Radiological Decay Constant [hr"1]

Radiological decay constant for radionuclide i.

tb Time Period of Ground Deposition [hr]

Time period during which the radioactivity on the ground is assumed to have been deposited (see Part 2 Table 1-3).

2.

The ground plane exposure pathway is considered to exist at all locations.

4.2.3.2 Inhalation CY-BY-170-301 Revision 15 Page 105 of 188 1.

The site-specific dose factor for inhalation is calculated by the following expression:

(4-10)

Inhalation Pathway Dose Factor [(mrem/yr)/(µCi/m3)]

Site-specific inhalation dose factor for age group a, nuclide i and organ j. The inhalation dose is calculated using (x/Q).

K' Conversion Constant (1 E6 pCi per µCi) [pCi/µCi]

BRa Individual Air Inhalation Rate [m3/yr]

The air intake rate for individuals in age group a. See Table E-5 of Regulatory Guide 1.109.

DFAa1J Inhalation Dose Conversion Factor [mrem/pCi]

Dose commitment to an individual in age group a to organ j per unit of activity of radionuclide i inhaled. Taken from Tables E-7 through E-10 of Regulatory Guide 1.109. The values for H-3 and Sr-90 are taken from NUREG 4013 (Reference 107).

2.

The inhalation exposure pathway is considered to exist at all locations.

4.2.3.3 Ingestion: Vegetation

1.

Food ingestion pathway doses are calculated at locations indicated by the land use census survey. If no real pathway exists within 5 miles of the station, the cow-milk pathway is assumed to be located at 5 miles. Food pathway calculations are not made for sectors in which the offsite regions near the station are over bodies of water.

CY-BY-170-301 Revision 15 Page 106 of 188

2.

The dose factor for consumption of vegetables is calculated by the following expression:

Vegetation Ingestion Pathway Dose Factor

[(m2 mrem/yr)/(µCi/sec)]

Site-specific vegetation ingestion dose factor for age group a, nuclide i and organ j. With the exception of H-3 and C-14 the vegetation dose is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per µCi) [pCi/µCi]

r Vegetation Retention Factor [dimensionless)

Yv Agricultural Productivity Yield [kg/ m2]

Ai Radiological Decay Constant [1 /sec]

Radiological decay constant for radionuclide i Aw Weathering Decay Constant [1 /sec]

DFLa1J Removal constant for physical loss of activity by weathering. See ODCM Part 2 Table 1-3.

Ingestion Dose Conversion Factor [mrem/pCi]

Ingestion dose conversion factor for age group a, nuclide i and organ j. Converts pCi ingested to mrem. Taken from Tables E-11 though E-14 of Regulatory Guide 1.109. The values for H-3 and Sr-90 are taken from NU REG 4013 (Reference 107).

Ua L Consumption Rate for Fresh Leafy Vegetation [kg/yr]

Consumption rate for fresh leafy vegetation for age group a.

Ua s Consumption Rate for Stored Vegetation [kg/yr]

Consumption rate for stored vegetation for age group a.

fL Local Leafy Vegetation Fraction [dimensionless]

CY-BY-170-301 Revision 15 Page 1 07 of 188 Fraction of the annual intake of fresh leafy vegetation that is grown locally.

f9 Local Stored Vegetation Fraction [dimensionless]

Fraction of the annual intake of stored vegetation that is grown locally.

tl Environmental Transport Time - Fresh Vegetation [sec]

Average time between harvest of leafy vegetation and its consumption.

th Environmental Transport Time - Stored Vegetation [sec)

Average time between harvest of stored vegetation and its consumption.

3.

The tritium dose from the vegetation pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the tritium vegetation pathway is:

Ra(H - 3)(\\'eg);[X IQ]= K' K"'(U; JL + u; Jg )DFLa(H-3)i0.75(0.5 I H)]

(4-12)

R a(H-3)(ve~j [x/q Tritium Vegetation Ingestion Pathway Dose Factor[(mrem/yr)/( µCi/m3>]

Site-specific tritium vegetation ingestion dose factor for age group a and organ j.

The tritium vegetation dose is calculated using [x/Q]

K"'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

0.75 Water Fraction [dimensionless]

The fraction of total vegetation that is water.

0.5 Specific Activity Ratio [dimensionless]

CY-BY-170-301 Revision 15 Page 1 08 of 188

4.

The Carbon-14 dose from the vegetation pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the Carbon-14 vegetation pathway is:

(4-12a)

K' a constant of unit conversion, 1 E 6 pCi/uCi UL gm/kg a

Leafy veg consumption rate adult (kg/yr)

U s a

Fraction of annual intake of fresh, leafy vegetation grown locally p

0.11 0.16 Stored veg consumption rate adult (kg/yr)

Fraction of annual intake of stored vegetation grown locally Ingestion Dose Factors The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.

The fraction of total plant mass that is natural carbon (dimensionless)

The concentration of natural carbon in the atmosphere (gm/m3)

4.2.3.4

1.

Ingestion Milk CY-BY -170-301 Revision 15 Page 109 of 188 The dose factor for consumption of milk is calculated by the following expressions:

R al{Mllk)J [D/Q]

Milk Ingestion Pathway Dose Factor

[(m2 mrem/yr)/(µCi/sec)]

(4-13)

Site-specific milk ingestion dose factor for age group a, nuclide i and organ j.

With the exception of H-3 and C-14 the milk dose factor is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per µCi) [pCi/µCi]

QF Feed Consumption [Kg/da]

Amount of feed consumed by milk animal each day. See ODCM Part 2 Table 1-3.

Uam Milk Consumption Rate [I/yr]

Milk consumption rate for age group a.

Fm Stable Element Transfer Coefficient for Milk [da/1]

Fraction of animal's daily intake of a particular chemical element that appears in each liter of milk (pCi/1 in milk per pCi/da ingested by animal).

See ODCM Part 2 Table 1-4.

fp Pasture Time Fraction [dimensionless]

Fraction of year that animal is on pasture.

fs Pasture Grass Fraction [dimensionless]

Fraction of animal feed that is pasture grass while animal is on pasture.

Yp Agricultural Productivity Yield - Pasture Grass [kg/m2]

The agricultural productivity by unit area of pasture feed grass.

Y s Agricultural Productivity Yield - Stored Feed [kg/m2]

The agricultural productivity by unit area of stored feed.

th Environmental Transport Time - Stored Feed [sec]

CY-BY -170-301 Revision 15 Page 110 of 188 Average time between harvest to consumption of stored feed by milk animal.

t, Environmental Transport Time - Pasture to Consumption

[sec]

Average time from pasture, to milk animal, to milk, to consumption.

All other terms have been previously defined.

The tritium dose from the milk pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the tritium milk pathway is:

(4-14)

R a(H-3)(mil'9j [x,'q Tritium Milk Ingestion Pathway Dose Factor

[(mrem/yr)/(µCi/m3)]

Site-specific tritium milk ingestion dose factor for age group a and organ j.

The tritium milk dose is calculated using [x/Q]

K"'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

0.75 Water Fraction [dimensionless]

The fraction of total feed that is water.

0.5 Specific Activity Ratio [dimensionless]

CY-BY-170-301 Revision 15 Page 111 of 188

2.

The Carbon-14 dose from the milk pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the Carbon-14 milk pathway is:

4.2.3.5

1.

K' a unit of conversion, 1.0E6 pCi/uCi K"'

gm/kg p

The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.

Fm Stable Element Transfer Data QF Milk cow feed consumption rate (kg/day wet)

Uap Cow milk consumption rate adult (I/yr)

(DFLi)a Ingestion Dose Factors 0.11 The fraction of total plant mass that is natural carbon (dimensionless) 0.16 The concentration of natural carbon in the atmosphere (gm/m3)

Ingestion: Meat The dose factor for consumption of meat is calculated by the following expression:

Q 1u )

[f f (1-f f )e-A1th]

R rD 1Q] = K' F\\: at F 1r)1DFL ) ~

+

P s e-Ait, (4 15) al{Meat)J ~ /

A. + A.

f ~

~

alj y

y I

w p

s Ra1(Meat)J [D/Q]

Meat Ingestion Pathway Dose Factor

[(m2 mrem/yr)/(µCi/sec)]

CY-BY-170-301 Revision 15 Page 112 of 188 Site-specific meat ingestion dose factor for age group a, nuclide i and organ j.

With the exception of H-3 and C-14 the meat dose factor is calculated using (D/Q).

Uat Meat Consumption Rate [kg/yr]

Meat consumption rate for age group a.

Ft Stable Element Transfer Coefficient for Meat [da/Kg]

Fraction of animal's daily intake of a particular chemical element that appears in each Kg of meat (pCi/Kg in meat per pCi/da ingested by animal). See ODCM Part 2 Table 1-4.

th Environmental Transport Time - Stored Feed [sec]

Average time between harvest to consumption of stored feed by meat animal.

tf Environmental Transport Time - Pasture to Consumption

[sec]

Average time from pasture, to meat animal, to meat, to consumption.

All other terms have been previously defined.

The tritium dose from the meat pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the tritium meat pathway is:

R a(H-3)(Meat)j [x IQ]=~ ~II Ff QF uaf (DF!Ja(H-3)} [0.75(0.5/ H)]

(4-16)

R a(H-3J(Mea,JJ [x IQ] Tritium Meat Ingestion Pathway Dose Factor (mrem/yr)/(µci/m3)]

Site-specific tritium meat ingestion dose factor for age group a and organ j.

The tritium meat dose is calculated using XI Q.

K"'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

0.75 Water Fraction [dimensionless]

The fraction of total feed that is water.

0.5 Specific Activity Ratio [dimensionless]

All other terms have been previously defined.

CY-BY-170-301 Revision 15 Page 113 of 188

2.

The Carbon-14 dose from the meat pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the Carbon-14 meat pathway is:

K' K"'

p Uap 0.11 0.16 a unit of conversion, 1.0E6 pCi/uCi Conversion Constant (1 E3 gm per kg)[gm/kg]

The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, pis taken to be unity.

Days/kg for each stable element Milk cow feed consumption rate (kg/day wet)

Meat consumption rate adult (kg/yr)

Ingestion Dose Factors the fraction of total plant mass that is natural carbon (dimensionless) the concentration of natural carbon in the atmosphere (gm/m3)

Table 4-1 CY-BY-170-301 Revision 15 Page 114 of 188 X/Q and D/Q Maxima at or Beyond the Unrestricted Area Boundary Downwind Nixed Node<V1nt> lel***

GrOllld Level Rtl1111 Dlrecttan Radius X/0 Radl111 D/0 Radl111 X/0 D/0 (Mttrl) (IIC/,..J) C*ttrt) (1/... Z) (*ttrl) (IIC/... J) (1/.. *Z, N

1175, 1,988E*07 1875.

1,98JE*09

1875, l,67dl*07 4.671E*09 IIME
1R9, 1,6771*07
1129, 1,9211*09 1129.

1,5311*07 4.2711*09 NE

1585, 1,5JOE*07 1515.

1,121E*09 1585.

7.176E*D7 4.318E*09 ENE

1254, 1,355!*07
1254, 1,7'4!-09
1254, 8,I08l*D7 5,0J61*09 E
1ZZ7, 1,681E*D7 1227.

2,JJ5E*09

1227, 1,14JE*06 6.226!*09 ESE
991, Z,5191*07
991, J.540E*D9
991, 1,6921*06 9,896E*D9 SE 1006,
  • J,OZOE*07
1006, J,5711!*09 1006.

2.480E*06 1, 1t8E*OI SSE

800, 4.4971!*07
800, J,761E*09
800, 4, 1S2E*06 1.420E-OI s
94S, 2.2491*01 945.

Z,1921*09 945.

1,9461*06 9.J~E-09 ssv 975.

1.476£*07 975.

1,970!*09 975.

1,SOSE*06 6.672!*09 sv

1067, 1,148E*07 1067.

1,716E*09 1067.

9.Z79E*07 5.J16E*09..

vsv

1212, 1, 1991*07
1212, 1,90JE*D9
1212, 7,646E*D7 5,00U*D9
1189, 1,758E*OT 1119.

1,170E*09

1119, 9,348E*07 5,3JOE*09 IINV
1227, 1,ZOSE-01
1227, 1,Z92E*09 1227.

6,543!*07 3,74SE*09 NV 1128.

1,6861*07 ma.

f.7191*09 1128.

1,8071*07 4.914E-09 NN 1044.

J,11471*07 11144,* J.22Jl*09 1044.

1,021*06 8.1171&-09 Byron Site Ntteorolotlcal 01t1 1171

  • 12/17 Note: Based on "Irrigation from the Rock River" letter from G.P. Lahti (Sargent and Lundy) to J.C. Golden (NSEP), June 4, 1990 and the formulas in Reg. Guide 1.109.

x/0 is used for beta skin, and inhalation dose pathways. See Sections 4.2.1, 4.2.2 and 4.2.3.

D/Q is used for produce and leafy vegetable pathways. See Section 4.2.3.

The ground level release data are provided for reference purposes only. Routine dose calculations are performed using mixed mode data.

Radius is the approximate distance from the midpoint between gaseous effluent release points to the location of the highest x/Q or D/Q at or beyond the unrestricted area boundary (UAB).

Table 4-2 CY -BY -170-301 Revision 15 Page 115 of 188 X/Q and D/Q Maxima at or Beyond the Restricted Area Boundary DOIRlfnd Nf_, llode(Yent) let....

.,,..... Lewi lele**

DfreoU* laclf*

Ill lacll*

D/1 lecll*

'11 D/t

  • <*t.,..J C--,...:S) C*tere> Ct/... 2) C*ten) Ceec,irJ)* f 1/11"1)
m. 1.Jm-01
m. 1.ooq.o,
m. J.2"1*06 2.036E-oa "8.

l,1111*D7 SJI.

t.OWl*DI SJI.

!1.8161*06 3.193E-OS 921.

6.IOJl-07

!121.

1.1921*0, HI.

4.J111*06 2.646E-oa hll 474.

S.3411*07 474.

S.9411*0,

'74.

4.1141*06 2.346E-08 I

4'1.

6.6981*07 461.

7.9JGl*09 UI.

S.JS9E*D6 2.93DE-08 Ill 480.

7.1111*07 480.

1.9631*0, 4111.

S.4341*06 3.144E-OS II!

427.

1.1261*06 427.

t.06Sl*OI 427.

1.0241*0S 4.352E-08 Ill!

410.

t.3491*06 410.

1.7441*19 41D.

1.SD5!*DS 4.044E-oa I

295.

1.4411*06 295.

1.111l*OI 295.

1.J911*DS 5.707E-oa 1111 299.

9.3121*Pf 299.

l,l9Jl*l9 199.

9.JTa*D6 4.197E-08 Ill 451.

J.9491*07 451.

S.06H*09 451.

J.6661*06 2.095E-OS USU 316.

6.09111*07

    • 7.4251-09
    • 4.6991*06 3.088E-oa V

S19.

t.0411*06 319.

1.118*09 119.

6.0D91*06 3.275E-08 11111 SIS.

1.45'1*07 SIS.

6.0l1E*09 JIS.

4.312!*06 2.370E-Oa IN 445.

7.J941*07 44S.

6.1171*0, 445.

4.0611*06 2.198E-08 11111

'51.

6.181*07

'51.

6.1111*09 6'1.

1.91111*06 1.874E-08 IYf'on lfte Neteorolotfcat Dete 1/11

  • 11/17 Note: Based on "Irrigation from the Rock River" letter from G.P. Lahti (Sargent and Lundy) to J.C. Golden (NSEP), June 4, 1990 and the formulas in Reg. Guide 1.109.

The ground level release data are provided for reference purposes only. Routine dose calculations are performed using mixed mode data.

Radius is the approximate distance from the midpoint between gaseous effluent release points to the location of the highest x/Q or D/Q at or beyond the restricted area boundary (RAB).

CY-BY-170-301 Revision 15 Page 116 of 188 Table 4-3 Maximum Offsite Gamma-x/Q Downwind Ground Vent Direction Radius Gamma-x/Q Gamma-x/Q (meters)

(sec/m**3)

(sec/m**3)

N 1875 4.80E-07 1.46E-07 NNE 1829 4.16E-07 1.36E-07 NE 1585 4.34E-07 1.31 E-07 ENE 1234 4.83E-07 1.27E-07 E

1227 6.10E-07 1.50E-07 ESE 991 8.73E-07 2.13E-07 SE 1006 1.24E-06 2.45E-07 SSE 800 1.83E-06 3.02E-07 s

945 9.68E-07 1.85E-07 SSW 975 6.69E-07 1.34E-07 SW 1067 4.84E-07 1.08E-07 WSW 1212 4.19E-07 1.11 E-07 w

1189 5.07E-07 1.39E-07 WNW 1227 3.54E-07 9.70E-08 NW 1128 4.61 E-07 1.29E-07 NNW 1044 7.43E-07 2.15E-07

Table 4-4 xtQ and D/Q at the Nearest Resident Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release xtQ D/Q xtQ D/Q Miles meters sec/m3 m*2 sec/m3 m*2 NEAREST RESIDENCE N

2.67 4300

3. 70E-07 9.80E-10 6.30E-08 3.80E-10 NEAREST RESIDENCE NNE 0.99 1600 1.50E-06 5.30E-09 8.30E-08 1.70E-09 NEAREST RESIDENCE NE 1.18 1900 1.00E-06 3.40E-09 6.60E-08 1.1 OE-09 NEAREST RESIDENCE ENE 1.30 2100 8.20E-07 2.20E-09 4.60E-08 7.30E-10 NEAREST RESIDENCE E

1.30 2100 1.20E-06 2.80E-09 5.90E-08 9.40E-10 NEAREST RESIDENCE ESE 1.43 2300 9.10E-07 2.10E-09 5.10E-08 7.10E-10 NEAREST RESIDENCE SE 0.75 1200 3.60E-06 7.40E-09 6.90E-08 2.00E-09 NEAREST RESIDENCE SSE 0.62 1000 3.80E-06 8.1 OE-09 5.40E-08 1.60E-09 NEAREST RESIDENCE s

0.50 800 3.40E-06 1.20E-08 8.40E-08 2.40E-09 NEAREST RESIDENCE SSW 0.62 1000

1. 70E-06 6.80E-09 6.40E-08 1.90E-09 NEAREST RESIDENCE SW 0.75 1200 7.80E-07 3.1 OE-09 3.50E-08 8.80E-10 NEAREST RESIDENCE WSW 1.68 2700 3.30E-07 1.40E-09 5.40E-08 6.50E-10 NEAREST RESIDENCE w

1.68 2700 5.50E-07 1.40E-09 5.20E-08 4.1OE-10 NEAREST RESIDENCE WNW 0.75 1200

1. 70E-06 5.20E-09 4.60E-08 1.00E-09 NEAREST RESIDENCE NW 0.99 1600 1.1 OE-06 3.30E-09 4.30E-08 7.30E-10 NEAREST RESIDENCE NNW 1.30 2100 8.50E-07 2.90E-09 6.20E-08 7.90E-10 CY-BY-170-301 Revision 15 I Page 117 of 188

CY-BY-170-301 Revision 15 Page 118 of 188 Table 4-5 1./Q and D/Q at the Nearest Cow Milk Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release x/Q D/Q x/Q D/Q miles meters sec/m3 m-2 sec/m3 m*2 COW MILK N

4.97 8000 1.50E-07 3.20E-10 4.20E-08 1.40E-10 COW MILK NNE 4.97 8000 1.30E-07 3.10E-10 3.90E-08 1.60E-10 COW MILK NE 1.86 3000 5.00E-07 1.50E-09 6.70E-08 6.20E-10 COW MILK ENE 4.97 8000 1.10E-07 2.00E-10 2.90E-08 1.10E-10 COW MILK E

4.97 8000 1.60E-07 2.70E-10 3.90E-08 1.40E-10 COW MILK ESE 4.97 8000 1.40E-07 2.30E-10 3.50E-08 1.20E-10 COW MILK SE 4.97 8000 2.00E-07 2.70E-10 3.80E-08 1.40E-10 COW MILK SSE 4.97 8000 1.50E-07 2.20E-10 3.10E-08 1.20E-10 COW MILK s

4.78 7700 9.10E-08 2.40E-10 2.90E-08 1.50E-10 COW MILK SSW 4.97 8000 6.10E-08 1.80E-10 2.20E-08 1.20E-10 COW MILK SW 4.97 8000 3.90E-08 1.10E-10 1.50E-08 7.10E-11 COW MILK WSW 4.97 8000 6.30E-08 2.10E-10 2.50E-08 1.30E-10 COW MILK w

2.49 4000 3.00E-07 7.20E-10 4.90E-08 2.60E-10 COW MILK WNW 3.29 5300 1.70E-07 4.00E-10 3.40E-08 1.50E-10 COW MILK NW 2.98 4800 2.10E-07 4.90E-10 3.70E-08 1.80E-10 COW MILK NNW 4.97 8000 1.10E-07 2.70E-10 3.50E-08 1.20E-10

Table 4-6 CY-BY-170-301 Revision 15 Page 119 of 188 1JQ and D/Q at the Nearest Cow Meat Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release x!Q D/Q xiQ D/Q miles meters sec/m3 m-2 sec/m3 m-2 COW MEAT N

2.98 4800 3.10E-07 8.10E-10 6.00E-08 3.20E-10 COW MEAT NNE 1.49 2400 7.70E-07 2.60E-09 7.60E-08 9.90E-10 COW MEAT NE 3.42 5500 2.00E-07 5.30E-10 5.20E-08 2.70E-10 COW MEAT ENE 2.30 3700 3.40E-07 8.10E-10 4.30E-08 3.50E-10 COW MEAT E

2.24 3600 5.00E-07 1.10E-09 5.80E-08 4.70E-10 COW MEAT ESE 1.49 2400 8.50E-07 2.00E-09 5.10E-08 6.80E-10 COW MEAT SE 1.68 2700 9.80E-07 1.80E-09 5.90E-08 6.90E-10 COW MEAT SSE 3.17 5100 2.90E-07 4.90E-10 4.10E-08 2.40E-10 COW MEAT s

0.56 900 2.80E-06 9.90E-09 7.70E-08 2.10E-09 COW MEAT SSW 2.17 3500 2.10E-07 8.00E-10 4.00E-08 4.30E-10 COW MEAT SW 3.17 5100 7.60E-08 2.50E-10 2.10E-08 1.50E-10 COW MEAT WSW 1.68 2700 3.30E-07 1.40E-09 5.40E-08 6.50E-10 COW MEAT w

1.68 2700 5.50E-07 1.40E-09 5.20E-08 4.10E-10 COW MEAT WNW 3.29 5300 1.70E-07 4.00E-10 3.40E-08 1.50E-10 COW MEAT NW 3.79 6100 1.50E-07 3.20E-10 3.30E-08 1.30E-10 COW MEAT NNW 1.37 2200 7.90E-07 2.70E-09 6.20E-08 7.50E-10

N l"d UCI e B one L" 1ver H-3 O.OOE+OO O.OOE+OO C-14 O.OOE+OO O.OOE+OO Na-24 1.20E+07 1.20E+07 Cr-51 4.65E+06 4.65E+06 Mn-54 1.38E+09 1.38E+09 Mn-56 9.03E+05 9.03E+05 Fe-55 O.OOE+OO O.OOE+OO Fe-59 2.73E+08 2.73E+08 Co-58 3.80E+08 3.80E+08 Co-60 2.15E+10 2.15E+10 Ni-63 O.OOE+OO O.OOE+OO Ni-65 2.97E+05 2.97E+05 Cu-64 6.05E+05 6.05E+05 Zn-65 7.46E+08 7.46E+08 Zn-69 O.OOE+OO O.OOE+OO Br-83 4.87E+03 4.87E+03 Br-84 2.03E+05 2.03E+05 Br-85 O.OOE+OO O.OOE+OO Rb-86 9.01E+06 9.01E+06 Rb-88 3.31E+04 3.31 E+04 Rb-89 1.23E+05 1.23E+05 Sr-89 2.16E+04 2.16E+04 Sr-90 O.OOE+OO O.OOE+OO Sr-91 2.14E+06 2.14E+06 Sr-92 7.76E+05 7.76E+05 Y-90 4.50E+03 4.50E+03 Y-91M 1.00E+05 1.00E+05 Y-91 1.07E+06 1.07E+06 Y-92 1.80E+05 1.80E+05 Y-93 1.83E+05 1.83E+05 Zr-95 2.45E+08 2.45E+08 Zr-97 2.96E+06 2.96E+06 Nb-95 1.37E+08 1.37E+08 Mo-99 3.99E+06 3.99E+06 Tc-99M 1.84E+05 1.84E+05 Tc-101 2.03E+04 2.03E+04 Ru-103 1.08E+08 1.08E+08 Ru-105 6.36E+05 6.36E+05 Ru-106 4.22E+08 4.22E+08 Ag-110M 3.45E+09 3.45E+09 Table 4-7 Ground Plane Dose Factors TB d O IY Th "d

1yro1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.20E+07 1.20E+07 4.65E+06 4.65E+06 1.38E+09 1.38E+09 9.03E+05 9.03E+05 O.OOE+OO O.OOE+OO 2.73E+08 2.73E+08 3.80E+08 3.80E+08 2.15E+10 2.15E+10 O.OOE+OO O.OOE+OO 2.97E+05 2.97E+05 6.05E+05 6.05E+05 7.46E+08 7.46E+08 O.OOE+OO O.OOE+OO 4.87E+03 4.87E+03 2.03E+05 2.03E+05 O.OOE+OO O.OOE+OO 9.01 E+06 9.01E+06 3.31 E+04 3.31 E+04 1.23E+05 1.23E+05 2.16E+04 2.16E+04 O.OOE+OO O.OOE+OO 2.14E+06 2.14E+06 7.76E+05 7.76E+05 4.50E+03 4.50E+03 1.00E+05 1.00E+05 1.07E+06 1.07E+06 1.80E+05 1.80E+05 1.83E+05 1.83E+05 2.45E+08 2.45E+08 2.96E+06 2.96E+06 1.37E+08 1.37E+08 3.99E+06 3.99E+06 1.84E+05 1.84E+05 2.03E+04 2.03E+04 1.08E+08 1.08E+08 6.36E+05 6.36E+05 4.22E+08 4.22E+08 3.45E+09 3.45E+09 K"d 1 ney O.OOE+OO O.OOE+OO 1.20E+07 4.65E+06 1.38E+09 9.03E+05 O.OOE+OO 2.73E+08 3.80E+08 2.15E+10 O.OOE+OO 2.97E+05 6.05E+05 7.46E+08 O.OOE+OO 4.87E+03 2.03E+05 O.OOE+OO 9.01E+06 3.31E+04 1.23E+05 2.16E+04 O.OOE+OO 2.14E+06 7.76E+05 4.50E+03 1.00E+05 1.07E+06 1.80E+05 1.83E+05 2.45E+08 2.96E+06 1.37E+08 3.99E+06 1.84E+05 2.03E+04 1.08E+08 6.36E+05 4.22E+08 3.45E+09 CY-BY-170-301 Revision 15 Page 120 of 188 L ung GILLI O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.20E+07 1.20E+07 4.65E+06 4.65E+06 1.38E+09 1.38E+09 9.03E+05 9.03E+05 O.OOE+OO O.OOE+OO 2.73E+08 2.73E+08 3.80E+08 3.80E+08 2.15E+10 2.15E+10 O.OOE+OO O.OOE+OO 2.97E+05 2.97E+05 6.05E+05 6.05E+05 7.46E+08 7.46E+08 O.OOE+OO O.OOE+OO 4.87E+03 4.87E+03 2.03E+05 2.03E+05 O.OOE+OO O.OOE+OO 9.01 E+06 9.01E+06 3.31 E+04 3.31 E+04 1.23E+05 1.23E+05 2.16E+04 2.16E+04 O.OOE+OO O.OOE+OO 2.14E+06 2.14E+06 7.76E+05 7.76E+05 4.50E+03 4.50E+03 1.00E+05 1.00E+05 1.07E+06 1.07E+06 1.80E+05 1.80E+05 1.83E+05 1.83E+05 2.45E+08 2.45E+08 2.96E+06 2.96E+06 1.37E+08 1.37E+08 3.99E+06 3.99E+06 1.84E+05 1.84E+05 2.03E+04 2.03E+04 1.08E+08 1.08E+08 6.36E+05 6.36E+05 4.22E+08 4.22E+08 3.45E+09 3.45E+09

N l"d UCI e Te-125M Te-127M Te-127 Te-129M Te-129 Te-131M Te-131 Te-132 1-130 1-131 1-132 1-133 1-134 1-135 Cs-134 Cs-136 Cs-137 Cs-138 Ba-139 Ba-140 Ba-141 Ba-142 La-140 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Pr-144 Nd-147 W-187 Np-239 Notes:

Table 4-7 (Continued)

CY-BY-170-301 Revision 15 Page 121 of 188 Ground Plane Dose Factors (same for all age groups) 8 one L" 1ver T 8 d Th "d

K"d OIV 1vro1 1 nev L una G 1-LLI 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 2.31E+06 2.31 E+06 2.31 E+06 2.31 E+06 2.31E+06 2.31E+06 2.31 E+06 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 1.71E+06 1.71 E+06 1.71 E+06 1.71E+06 1.71E+06 1.71 E+06 1.71E+06

1) Units are m2 mrem/yr per µCi/sec.
2) All age groups are assumed to receive the same dose.

CY-BY-170-301 Revision 15 Page 122 of 188 Table 4-8 External Dose Factors for Standing on Contaminated Ground DFGu {mrem/hr Qer QCi/ m2}

Whole Body Whole Body Element Dose Factor Reference Element Dose Factor Reference H-3 O.OOE+OO 6

Be-7 5.95E-10 99 C-14 O.OOE+OO 6

F-18 1.19E-08 99 Na-22 2.42E-08 99 Na-24 2.SOE-08 6

Mg-27 1.14E-08 99 Mg-28 1.48E-08 99 Al-26 2.95E-08 99 Al-28 2.00E-08 99 P-32 O.OOE+OO 6

Cl-38 1.70E-08 99 Ar-41 1.39E-08 99 K-40 2.22E-09 99 K-42 4.64E-09 99 K-43 1.19E-08 99 Ca-47 1.14E-08 99 Sc-44 2.SOE-08 99 Sc-46m 1.21 E-09 99 Sc-46 2.24E-08 99 Sc-47 1.46E-09 99 Ti-44 1.95E-09 99 V-48 3.21E-08 99 Cr-51 2.20E-10 6

Mn-52m 2.79E-08 99 Mn-52 3.SOE-08 99 Mn-54 5.BOE-09 6

Mn-56 1.10E-08 6

Fe-52 9.12E-09 99 Fe-55 O.OOE+OO 6

Fe-59 8.00E-09 6

Co-57 1.65E-09 99 Co-58 7.00E-09 6

Co-60 1.70E-08 6

Ni-63 0.00E+OO 6

Ni-65 3.70E-09 6

Cu-64 1.SOE-09 6

Cu-67 1.52E-09 99 Cu-68 8.60E-09 1

Zn-65 4.00E-09 6

Zn-69m 5.06E-09 99 Zn-69 O.OOE+OO 6

Ga-66 2.70E-08 99 Ga-67 1.89E-09 99 Ga-68 1.24E-08 99 Ga-72 3.00E-08 99 Ge-77 1.34E-08 99 As-72 2.23E-08 99 As-73 1.16E-10 99 As-74 9.41E-09 99 As-76 6.46E-09 99 As-77 1.79E-10 99 Se-73 1.38E-08 99 Se-75 4.98E-09 99 Br-77 3.84E-09 99 Br-80 2.01E-09 99 Br-82 3.00E-08 99 Br-83 6.40E-11 6

Br-84 1.20E-08 6

Br-85 O.OOE+OO 6

Kr-79 3.07E-09 99 Kr-81 1.59E-10 99 Kr-83m 1.42E-11 99 Kr-85m 2.24E-09 99 Kr-85 1.35E-10 99 Kr-87 1.03E-08 99 Kr-88 2.07E-08 99 Kr-90 1.56E-08 99 Rb-84 1.07E-08 99 Rb-86 6.30E-10 6

Rb-87 O.OOE+OO 99 Rb-88 3.SOE-09 6

Rb-89 1.SOE-08 6

Sr-85 6.16E-09 99 Sr-87m 3.92E-09 99 Sr-89 5.60E-13 6

Sr-90 1.84E-11 99 Sr-91 7.10E-09 6

Sr-92 9.00E-09 6

Y-86 4.00E-08 99 Y-87 5.53E-09 99 Y-88 2.88E-08 99 Y-90 2.20E-12 6

Y-91m 3.BOE-09 6

Y-91 2.40E-11 6

Y-92 1.60E-09 6

Y-93 5.70E-10 6

Zr-95 5.00E-09 6

Zr-97 5.SOE-09 6

Nb-94 1.84E-08 99 Nb-95 5.10E-09 6

Nb-97m 8.57E-09 99 Nb-97 8.48E-09 99 Mo-99 1.90E-09 6

Tc-99m 9.60E-10 6

Tc-101 2.70E-09 6

Tc-104 1.83E-081 Ru-97 2.99E-09 99 Ru-103 3.60E-09 6

Ru-105 4.SOE-09 6

Ru-106 1.SOE-09 6

Pc-109 3.BOE-10 99 Cd-109 1.12E-10 99 ln-111 5.11E-09 99 ln-115m 2.01E-09 99 ln-116 O.OOE+002 Sn-113 1.15E-09 99 Sn-117m 1.96E-08 99 Sn-119m 7.0SE-11 99 Sb-117 O.OOE+002 Sb-122 2.71E-09 1

Sb-124 1.16E-081 Sb-125 4.56E-09 99 Sb-126 7.13E-10 99 Ag-108m 1.92E-08 99 Ag-108 1.14E-09 99 Ag-110m 1.BOE-08 6

Ag-111 6.75E-10 99 Te-121m 2.65E-09 99 Te-121 6.75E-09 99 Te-123m 1.88E-09 99 Te-125m 3.SOE-11 6

CY-BY-170-301 Revision 15 Page 123 of 188 Table 4-8 (cont.)

External Dose Factors for Standing on Contaminated Ground DFGn (mrem/hr ~er ~Ci/ m 2

}

Whole Body Whole Body Element Dose Factor Reference Element Dose Factor Reference Te-125 O.OOE+002 Te-127m 1.10E-12 6

Te-127 1.00E-11 6

Te-129m 7.70E-10 6

Te-129 7.10E-10 6

Te-131m 8.40E-09 6

Te-131 2.20E-09 6

Te-132 1.70E-08 6

Te-134 1.05E-08 99 1-123 2.12E-09 99 1-124 1.23E-08 99 1-125 2.89E-10 99 1-130 1.40E-08 6

1-131 2.BOE-09 6

1-132 1.70E-09 6

1-133 3.70E-09 6

1-134 1.60E-08 6

1-135 1.20E-08 6

Xe-127 3.44E-09 99 Xe-129m 5.57E-10 99 Xe-131m 2.13E-10 99 Xe-133m 4.81E-10 99 Xe-133 5.91E-10 99 Xe-135m 5.23E-09 99 Xe-135 3.36E-09 99 Xe-137 4.26E-09 99 Xe-138 1.30E-08 99 Cs-129 3.39E-09 99 Cs-132 8.40E-09 99 Cs-134 1.20E-08 6

Cs-136 1.50E-08 6

Cs-137 7.17E-094 99 Cs-138 2.10E-08 6

Cs-139 5.15E-09 99 Ba-131 5.74E-09 99 Ba-133m 8.10E-10 99 Ba-133 4.85E-09 99 Ba-135m 7.26E-10 99 Ba-137m 7.17E-09 99 Ba-137 O.OOE+002 Ba-139 2.40E-09 6

Ba-La-140 1.71E-086 6

Ba-141 4.30E-09 6

Ba-142 7.90E-09 6

La-142 1.50E-08 6

Ce-139 2.04E-09 99 Ce-141 5.50E-10 6

Ce-143 2.20E-09 6

Ce-Pr-144 5.20E-107 6

Pr-142 1.84E-09 99 Pr-143 0.00E+OO 6

Nd-147 1.00E-09 6

Nd-149 5.32E-09 99 Pm-145 3.38E-10 99 Pm-148m 2.35E-08 99 Pm-148 7.22E-09 99 Pm-149 5.32E-10 99 Sm-153 8.95E-10 99 Eu-152 1.30E-08 99 Eu-154 1.41E-08 99 Eu-155 8.27E-10 99 Gc-153 1.46E-09 99 Dy-157 4.39E-09 99 Er-169 6.12E-14 99 Er-171 5.11E-09 99 Tm-170 3.41E-10 99 Yb-169 4.12E-09 99 Yb-175 4.94E-10 99 Lu-177 4.60E-10 99 Hf-181 6.67E-09 99 Ta-182 1.42E-08 99 Ta-183 2.93E-091 W-187 3.10E-09 6

Re-188 1.89E-09 99 Os-191 9.83E-10 99 lr-194 2.31E-09 99 Pt-195m 9.79E-10 99 Pt-197 3.57E-10 99 Au-195m 2.54E-09 99 Au-195 1.14E-09 99 Au-198 5.19E-09 99 Au-199 1.18E-09 99 Hg-197 9.33E-10 99 Hg-203 2.89E-09 99 Tl-201 1.24E-09 99 Tl-206 O.OOE+002 Tl-208 3.58E-08 99 Pb-203 3.88E-09 99 Pb-210 3.57E-11 99 Pb-212 1.91E-09 99 Pb-214 3.18E-09 99 Bi-206 3.74E-08 99 Bi-207 1.77E-08 99 Bi-214 1.71E-08 99 Ra-226 8.78E-11 99 Th-232 8.14E-12 99 U-238 7.98E-12 99 Np-239 9.50E-10 6

Am-241 3.48E-10 99 Value derived by comparing the percentage and MeVofthe nuclide's gammas and then comparing to Cesium-137, as a value was not available in the literature.

2 0.0 due to low yield and short half-life. A value was not available in the literature.

4 Cs-137 value is from daughter product Ba-137m (7.17E-09) because ground plane dose from Cs-137 is due to gamma radiation emitted by Ba-137m. This value is from reference 99.

6 7

Table 4-8 (cont.)

CY-BY-170-301 Revision 15 Page 124 of 188 External Dose Factors for Standing on Contaminated Ground DFG1i (mrem/hr per pCi/ m2)

Value is the sum of Ba-140 (2.10E-9) and La-140 (1.SOE-8) from reference 6. In Reference 6, see Table E-6.

Value is the sum of Ce-144 (3.20E-10) and Pr-144 (2.00E-10) from reference 6.

Note:

Dose assessments for 10CFR20 and 40CFR190 compliance are made for an adult only.

Dose assessments for 1 OCFRSO Appendix are made using dose factors of Regulatory Guide 1.109 (Reference 6) for all age groups.

N l"d UCI e B one H-3 O.OOE+OO C-14 1.82E+04 Na-24 1.02E+04 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 2.46E+04 Fe-59 1.18E+04 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 4.32E+05 Ni-65 1.54E+OO Cu-64 O.OOE+OO Zn-65 3.24E+04 Zn-69 3.38E-02 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 3.04E+05 Sr-90 2.87E+07 Sr-91 6.19E+01 Sr-92 6.74E+OO Y-90 2.09E+03 Y-91M 2.61 E-01 Y-91 4.62E+05 Y-92 1.03E+01 Y-93 9.44E+01 Zr-95 1.07E+05 Zr-97 9.68E+01 Nb-95 1.41 E+04 Mo-99 O.OOE+OO Tc-99M 1.03E-03 Tc-101 4.18E-05 Ru-103 1.53E+03 Ru-105 7.90E-01 Ru-106 6.91E+04 Ag-110M 1.08E+04 Table 4-9 CY-BY-170-301 Revision 15 Page 125 of 188 Adult Inhalation Dose Factors L'

T B d Th

'd K'd 1ver O IY 1yro1 1 ney L ung GILLI 7.18E+02 7.18E+02 7.18E+02 7.18E+02 7.18E+02 7.18E+02 3.41E+03 3.41E+03 3.41 E+03 3.41E+03 3.41E+03 3.41E+03 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 O.OOE+OO 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 3.96E+04 6.30E+03 O.OOE+OO 9.84E+03 1.40E+06 7.74E+04 1.24E+OO 1.83E-01 O.OOE+OO 1.30E+OO 9.44E+03 2.02E+04 1.70E+04 3.94E+03 O.OOE+OO O.OOE+OO 7.21 E+04 6.03E+03 2.78E+04 1.06E+04 O.OOE+OO O.OOE+OO 1.02E+06 1.88E+05 1.58E+03 2.07E+03 O.OOE+OO O.OOE+OO 9.28E+05 1.06E+05 1.15E+04 1.48E+04 O.OOE+OO O.OOE+OO 5.97E+06 2.85E+05 3.14E+04 1.45E+04 O.OOE+OO O.OOE+OO 1.78E+05 1.34E+04 2.10E-01 9.12E-02 O.OOE+OO O.OOE+OO 5.60E+03 1.23E+04 1.46E+OO 6.15E-01 O.OOE+OO 4.62E+OO 6.78E+03 4.90E+04 1.03E+05 4.66E+04 O.OOE+OO 6.90E+04 8.64E+05 5.34E+04 6.51 E-02 4.52E-03 O.OOE+OO 4.22E-02 9.20E+02 1.63E+01 O.OOE+OO 2.41E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.32E+02 O.OOE+OO 3.13E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.64E-03 O.OOE+OO 1.28E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+05 5.90E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.66E+04 3.87E+02 1.93E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.34E-09 2.56E+02 1.70E+02 O.OOE+OO O.OOE+OO O.OOE+OO 9.28E-12 O.OOE+OO 8.72E+03 O.OOE+OO O.OOE+OO 1.40E+06 3.50E+05 O.OOE+OO 5.77E+05 O.OOE+OO O.OOE+OO 9.60E+06 7.22E+05 O.OOE+OO 2.50E+OO O.OOE+OO O.OOE+OO 3.65E+04 1.91 E+05 O.OOE+OO 2.91 E-01 O.OOE+OO O.OOE+OO 1.65E+04 4.30E+04 O.OOE+OO 5.61E+01 O.OOE+OO O.OOE+OO 1.70E+05 5.06E+05 O.OOE+OO 1.02E-02 O.OOE+OO O.OOE+OO 1.92E+03 1.33E+OO O.OOE+OO 1.24E+04 O.OOE+OO O.OOE+OO 1.70E+06 3.85E+05 O.OOE+OO 3.02E-01 O.OOE+OO O.OOE+OO 1.57E+04 7.35E+04 O.OOE+OO 2.61E+OO O.OOE+OO O.OOE+OO 4.85E+04 4.22E+05 3.44E+04 2.33E+04 O.OOE+OO 5.42E+04 1.77E+06 1.50E+05 1.96E+01 9.04E+OO O.OOE+OO 2.97E+01 7.87E+04 5.23E+05 7.82E+03 4.21 E+03 O.OOE+OO 7.74E+03 5.0SE+OS 1.04E+05 1.21E+02 2.30E+01 O.OOE+OO 2.91 E+02 9.12E+04 2.48E+05 2.91 E-03 3.70E-02 O.OOE+OO 4.42E-02 7.64E+02 4.16E+03 6.02E-05 5.90E-04 O.OOE+OO 1.08E-03 3.99E+02 1.09E-11 O.OOE+OO 6.58E+02 O.OOE+OO 5.83E+03 5.05E+05 1.10E+05 O.OOE+OO 3.11 E-01 O.OOE+OO 1.02E+OO 1.10E+04 4.82E+04 O.OOE+OO 8.72E+03 O.OOE+OO 1.34E+05 9.36E+06 9.12E+05 1.00E+04 5.94E+03 O.OOE+OO 1.97E+04 4.63E+06 3.02E+05

N l"d UCI e B one Te-125M 3.42E+03 Te-127M 1.26E+04 Te-127 1.40E+OO Te-129M 9.76E+03 Te-129 4.98E-02 Te-131M 6.99E+01 Te-131 1.11 E-02 Te-132 2.60E+02 1-130 4.58E+03 1-131 2.52E+04 1-132 1.16E+03 1-133 8.64E+03 1-134 6.44E+02 1-135 2.68E+03 Cs-134 3.73E+05 Cs-136 3.90E+04 Cs-137 4.78E+05 Cs-138 3.31 E+02 Ba-139 9.36E-01 Ba-140 3.90E+04 Ba-141 1.00E-01 Ba-142 2.63E-02 La-140 3.44E+02 La-142 6.83E-01 Ce-141 1.99E+04 Ce-143 1.86E+02 Ce-144 3.43E+06 Pr-143 9.36E+03 Pr-144 3.01 E-02 Nd-147 5.27E+03 W-187 8.48E+OO Np-239 2.30E+02 Notes:

CY-BY-170-301 Revision 15 Page 126 of 188 Table 4-9 (Continued)

Adult Inhalation Dose Factors L"

TB d Th "d

K"d 1ver o IY 1yro1 1 ney L ung GILLI 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 6.42E-01 3.10E-01 1.06E+OO 5.10E+OO 6.51E+03 5.74E+04 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 1.34E+04 5.28E+03 1.14E+06 2.09E+04 O.OOE+OO 7.69E+03 3.58E+04 2.05E+04 1.19E+07 6.13E+04 O.OOE+OO 6.28E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 O.OOE+OO 4.06E+02 1.48E+04 4.52E+03 2.15E+06 2.58E+04 O.OOE+OO 8.88E+03 1.73E+03 6.15E+02 2.98E+04 2.75E+03 O.OOE+OO 1.01E+OO 6.98E+03 2.57E+03 4.48E+05 1.11E+04 O.OOE+OO 5.25E+03 8.48E+05 7.28E+05 O.OOE+OO 2.87E+05 9.76E+04 1.04E+04 1.46E+05 1.10E+05 O.OOE+OO 8.56E+04 1.20E+04 1.17E+04 6.21 E+05 4.28E+05 O.OOE+OO 2.22E+05 7.52E+04 8.40E+03 6.21 E+02 3.24E+02 O.OOE+OO 4.80E+02 4.86E+01 1.86E-03 6.66E-04 2.74E-02 O.OOE+OO 6.22E-04 3.76E+03 8.96E+02 4.90E+01 2.57E+03 O.OOE+OO 1.67E+01 1.27E+06 2.18E+05 7.53E-05 3.36E-03 O.OOE+OO 7.00E-05 1.94E+03 1.16E-07 2.70E-05 1.66E-03 O.OOE+OO 2.29E-05 1.19E+03 1.57E-16 1.74E+02 4.58E+01 O.OOE+OO O.OOE+OO 1.36E+05 4.58E+05 3.10E-01 7.72E-02 O.OOE+OO O.OOE+OO 6.33E+03 2.11E+03 1.35E+04 1.53E+03 O.OOE+OO 6.26E+03 3.62E+05 1.20E+05 1.38E+02 1.53E+01 O.OOE+OO 6.08E+01 7.98E+04 2.26E+05 1.43E+06 1.84E+05 O.OOE+OO 8.48E+05 7.78E+06 8.16E+05 3.75E+03 4.64E+02 O.OOE+OO 2.16E+03 2.81E+05 2.00E+05 1.25E-02 1.53E-03 O.OOE+OO 7.05E-03 1.02E+03 2.15E-08 6.10E+03 3.65E+02 O.OOE+OO 3.56E+03 2.21E+05 1.73E+05 7.08E+OO 2.48E+OO O.OOE+OO O.OOE+OO 2.90E+04 1.55E+05 2.03E+02 1.24E+01 O.OOE+OO 7.00E+01 3.76E+04 1.19E+05

1)

Units are mrem/yr per µCi/m3.

N l"d UCI e B one H-3 O.OOE+OO C-14 2.60E+04 Na-24 1.38E+04 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 3.34E+04 Fe-59 1.59E+04 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 5.80E+05 Ni-65 2.18E+OO Cu-64 O.OOE+OO Zn-65 3.86E+04 Zn-69 4.83E-02 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 4.34E+05 Sr-90 3.31 E+07 Sr-91 8.80E+01 Sr-92 9.52E+OO Y-90 2.98E+03 Y-91M 3.70E-01 Y-91 6.61E+05 Y-92 1.47E+01 Y-93 1.35E+02 Zr-95 1.46E+05 Zr-97 1.38E+02 Nb-95 1.86E+04 Mo-99 O.OOE+OO Tc-99M 1.38E-03 Tc-101 5.92E-05 Ru-103 2.10E+03 Ru-105 1.12E+OO Ru-106 9.84E+04 Ag-110M 1.38E+04 Table 4-10 CY-BY-170-301 Revision 15 Page 127 of 188 Teen Inhalation Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung GILLI 7.25E+02 7.25E+02 7.25E+02 7.25E+02 7.25E+02 7.25E+02 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 O.OOE+OO 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 5.11E+04 8.40E+03 O.OOE+OO 1.27E+04 1.98E+06 6.68E+04 1.70E+OO 2.52E-01 O.OOE+OO 1.79E+OO 1.52E+04 5.74E+04 2.38E+04 5.54E+03 O.OOE+OO O.OOE+OO 1.24E+05 6.39E+03 3.70E+04 1.43E+04 O.OOE+OO O.OOE+OO 1.53E+06 1.78E+05 2.07E+03 2.78E+03 O.OOE+OO O.OOE+OO 1.34E+06 9.52E+04 1.51E+04 1.98E+04 O.OOE+OO O.OOE+OO 8.72E+06 2.59E+05 4.34E+04 1.98E+04 O.OOE+OO O.OOE+OO 3.07E+05 1.42E+04 2.93E-01 1.27E-01 O.OOE+OO O.OOE+OO 9.36E+03 3.67E+04 2.03E+OO 8.48E-01 O.OOE+OO 6.41 E+OO 1.11E+04 6.14E+04 1.34E+05 6.24E+04 O.OOE+OO 8.64E+04 1.24E+06 4.66E+04 9.20E-02 6.46E-03 O.OOE+OO 6.02E-02 1.58E+03 2.85E+02 O.OOE+OO 3.44E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.83E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.40E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.77E+04 5.46E+02 2.72E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.92E-05 3.52E+02 2.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.38E-07 O.OOE+OO 1.25E+04 O.OOE+OO O.OOE+OO 2.42E+06 3.71 E+05 O.OOE+OO 6.66E+05 O.OOE+OO O.OOE+OO 1.65E+07 7.65E+05 O.OOE+OO 3.51E+OO O.OOE+OO O.OOE+OO 6.07E+04 2.59E+05 O.OOE+OO 4.06E-01 O.OOE+OO O.OOE+OO 2.74E+04 1.19E+05 O.OOE+OO 8.00E+01 O.OOE+OO O.OOE+OO 2.93E+05 5.59E+05 O.OOE+OO 1.42E-02 O.OOE+OO O.OOE+OO 3.20E+03 3.02E+01 O.OOE+OO 1.77E+04 O.OOE+OO O.OOE+OO 2.94E+06 4.09E+05 O.OOE+OO 4.29E-01 O.OOE+OO O.OOE+OO 2.68E+04 1.65E+05 O.OOE+OO 3.72E+OO O.OOE+OO O.OOE+OO 8.32E+04 5.79E+05 4.58E+04 3.15E+04 O.OOE+OO 6.74E+04 2.69E+06 1.49E+05 2.72E+01 1.26E+01 O.OOE+OO 4.12E+01 1.30E+05 6.30E+05 1.03E+04 5.66E+03 O.OOE+OO 1.00E+04 7.51 E+05 9.68E+04 1.69E+02 3.22E+01 O.OOE+OO 4.11E+02 1.54E+05 2.69E+05 3.86E-03 4.99E-02 O.OOE+OO 5.76E-02 1.15E+03 6.13E+03 8.40E-05 8.24E-04 O.OOE+OO 1.52E-03 6.67E+02 8.72E-07 O.OOE+OO 8.96E+02 O.OOE+OO 7.43E+03 7.83E+05 1.09E+05 O.OOE+OO 4.34E-01 O.OOE+OO 1.41 E+OO 1.82E+04 9.04E+04 O.OOE+OO 1.24E+04 O.OOE+OO 1.90E+05 1.61E+07 9.60E+05 1.31E+04 7.99E+03 O.OOE+OO 2.50E+04 6.75E+06 2.73E+05

Nuclide Bone Te-125M 4.88E+03 Te-127M 1.80E+04 Te-127 2.01E+OO Te-129M 1.39E+04 Te-129 7.1 OE-02 Te-131M 9.84E+01 Te-131 1.58E-02 Te-132 3.60E+02 1-130 6.24E+03 1-131 3.54E+04 1-132 1.59E+03 1-133 1.22E+04 1-134 8.88E+02 1-135 3.70E+03 Cs-134 5.02E+05 Cs-136 5.15E+04 Cs-137 6.70E+05 Cs-138 4.66E+02 Ba-139 1.34E+OO Ba-140 5.47E+04 Ba-141 1.42E-01 Ba-142 3.70E-02 La-140 4.79E+02 La-142 9.60E-01 Ce-141 2.84E+04 Ce-143 2.66E+02 Ce-144 4.89E+06 Pr-143 1.34E+04 Pr-144 4.30E-02 Nd-147 7.86E+03 W-187 1.20E+01 Np-239 3.38E+02 Notes:

CY-BY-170-301 Revision 15 Page 128 of 188 Table 4-10 (Continued)

Teen Inhalation Dose Factors Liver T Body Thyroid Kidney Lung 2.24E+03 6.67E+02 1.40E+03 O.OOE+OO 5.36E+05 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 9.12E-01 4.42E-01 1.42E+OO 7.28E+OO 1.12E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 6.01E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 1.79E+04 7.17E+03 1.49E+06 2.75E+04 O.OOE+OO 4.91E+04 2.64E+04 1.46E+07 8.40E+04 O.OOE+OO 4.38E+03 1.58E+03 1.51 E+05 6.92E+03 O.OOE+OO 2.05E+04 6.22E+03 2.92E+06 3.59E+04 O.OOE+OO 2.32E+03 8.40E+02 3.95E+04 3.66E+03 O.OOE+OO 9.44E+03 3.49E+03 6.21E+05 1.49E+04 O.OOE+OO 1.13E+06 5.49E+05 O.OOE+OO 3.75E+05 1.46E+05 1.94E+05 1.37E+05 O.OOE+OO 1.10E+05 1.78E+04 8.48E+05 3.11E+05 O.OOE+OO 3.04E+05 1.21E+05 8.56E+02 4.46E+02 O.OOE+OO 6.62E+02 7.87E+01 9.44E-04 3.90E-02 O.OOE+OO 8.88E-04 6.46E+03 6.70E+01 3.52E+03 O.OOE+OO 2.28E+01 2.03E+06 1.06E-04 4.74E-03 O.OOE+OO 9.84E-05 3.29E+03 3.70E-05 2.27E-03 O.OOE+OO 3.14E-05 1.91E+03 2.36E+02 6.26E+01 O.OOE+OO O.OOE+OO 2.14E+05 4.25E-01 1.06E-01 O.OOE+OO O.OOE+OO 1.02E+04 1.90E+04 2.17E+03 O.OOE+OO 8.88E+03 6.14E+05 1.94E+02 2.16E+01 O.OOE+OO 8.64E+01 1.30E+05 2.02E+06 2.62E+05 O.OOE+OO 1.21 E+06 1.34E+07 5.31 E+03 6.62E+02 O.OOE+OO 3.09E+03 4.83E+05 1.76E-02 2.18E-03 O.OOE+OO 1.01 E-02 1.75E+03 8.56E+03 5.13E+02 O.OOE+OO 5.02E+03 3.72E+05 9.76E+OO 3.43E+OO O.OOE+OO O.OOE+OO 4.74E+04 2.88E+02 1.77E+01 O.OOE+OO 1.00E+02 6.49E+04

1)

Units are mrem/yr per µCi/m3*

GI-LLI 7.50E+04 1.59E+05 8.08E+04 4.05E+05 1.62E+03 6.21E+05 1.51 E+01 4.63E+05 9.12E+03 6.49E+03 1.27E+03 1.03E+04 2.04E+01 6.95E+03 9.76E+03 1.09E+04 8.48E+03 2.70E-01 6.45E+03 2.29E+05 7.46E-04 4.79E-10 4.87E+05 1.20E+04 1.26E+05 2.55E+05 8.64E+05 2.14E+05 2.35E-04 1.82E+05 1.77E+05 1.32E+05

Nuclide Bone H-3 O.OOE+OO C-14 3.59E+04 Na-24 1.61E+04 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 4.74E+04 Fe-59 2.07E+04 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 8.21 E+05 Ni-65 2.99E+OO Cu-64 O.OOE+OO Zn-65 4.26E+04 Zn-69 6.70E-02 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 5.99E+05 Sr-90 3.85E+07 Sr-91 1.21E+02 Sr-92 1.31E+01 Y-90 4.11E+03 Y-91M 5.0?E-01 Y-91 9.14E+05 Y-92 2.04E+01 Y-93 1.86E+02 Zr-95 1.90E+05 Zr-97 1.88E+02 Nb-95 2.35E+04 Mo-99 O.OOE+OO Tc-99M 1.78E-03 Tc-101 8.10E-05 Ru-103 2.79E+03 Ru-105 1.53E+OO Ru-106 1.36E+05 Ag-110M 1.69E+04 Table 4-11 CY-BY-170-301 Revision 15 Page 129 of 188 Child Inhalation Dose Factors Liver T Body Thyroid Kidney Lung GI-LLI 6.40E+02 6.40E+02 6.40E+02 6.40E+02 6.40E+02 6.40E+02 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 O.OOE+OO 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 4.29E+04 9.51E+03 O.OOE+OO 1.00E+04 1.58E+06 2.29E+04 1.66E+OO 3.12E-01 O.OOE+OO 1.67E+OO 1.31 E+04 1.23E+05 2.52E+04 7.77E+03 O.OOE+OO O.OOE+OO 1.11 E+05 2.87E+03 3.34E+04 1.67E+04 O.OOE+OO O.OOE+OO 1.27E+06 7.07E+04 1.77E+03 3.16E+03 O.OOE+OO O.OOE+OO 1.11 E+06 3.44E+04 1.31E+04 2.26E+04 O.OOE+OO O.OOE+OO 7.07E+06 9.62E+04 4.63E+04 2.80E+04 O.OOE+OO O.OOE+OO 2.75E+05 6.33E+03 2.96E-01 1.64E-01 O.OOE+OO O.OOE+OO 8.18E+03 8.40E+04 1.99E+OO 1.07E+OO O.OOE+OO 6.03E+OO 9.58E+03 3.67E+04 1.13E+05 7.03E+04 O.OOE+OO 7.14E+04 9.95E+05 1.63E+04 9.66E-02 8.92E-03 O.OOE+OO 5.85E-02 1.42E+03 1.02E+04 O.OOE+OO 4.74E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.48E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.53E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+05 1.14E+05 O.OOE+OO O.OOE+OO O.OOE+OO 7.99E+03 5.62E+02 3.66E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.72E+01 3.45E+02 2.90E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.89E+OO O.OOE+OO 1.72E+04 O.OOE+OO O.OOE+OO 2.16E+06 1.67E+05 O.OOE+OO 7.66E+05 O.OOE+OO O.OOE+OO 1.48E+07 3.43E+05 O.OOE+OO 4.59E+OO O.OOE+OO O.OOE+OO 5.33E+04 1.74E+05 O.OOE+OO 5.25E-01 O.OOE+OO O.OOE+OO 2.40E+04 2.42E+05 O.OOE+OO 1.11 E+02 O.OOE+OO O.OOE+OO 2.62E+05 2.68E+05 O.OOE+OO 1.84E-02 O.OOE+OO O.OOE+OO 2.81E+03 1.72E+03 O.OOE+OO 2.44E+04 O.OOE+OO O.OOE+OO 2.63E+06 1.84E+05 O.OOE+OO 5.81 E-01 O.OOE+OO O.OOE+OO 2.39E+04 2.39E+05 O.OOE+OO 5.11E+OO O.OOE+OO O.OOE+OO 7.44E+04 3.89E+05 4.18E+04 3.70E+04 O.OOE+OO 5.96E+04 2.23E+06 6.11E+04 2.72E+01 1.60E+01 O.OOE+OO 3.89E+01 1.13E+05 3.51 E+05 9.18E+03 6.55E+03 O.OOE+OO 8.62E+03 6.14E+05 3.70E+04 1.72E+02 4.26E+01 O.OOE+OO 3.92E+02 1.35E+05 1.27E+05 3.48E-03 5.77E-02 O.OOE+OO 5.07E-02 9.51E+02 4.81E+03 8.51 E-05 1.0BE-03 O.OOE+OO 1.45E-03 5.85E+02 1.63E+01 O.OOE+OO 1.07E+03 O.OOE+OO 7.03E+03 6.62E+05 4.48E+04 O.OOE+OO 5.55E-01 O.OOE+OO 1.34E+OO 1.59E+04 9.95E+04 O.OOE+OO 1.69E+04 O.OOE+OO 1.84E+05 1.43E+07 4.29E+05 1.14E+04 9.14E+03 O.OOE+OO 2.12E+04 5.48E+06 1.00E+05

Nuclide Bone Te-125M 6.73E+03 Te-127M 2.49E+04 Te-127 2.77E+OO Te-129M 1.92E+04 Te-129 9.77E-02 Te-131M 1.34E+02 Te-131 2.17E-02 Te-132 4.81 E+02 1-130 8.18E+03 1-131 4.81 E+04 1-132 2.12E+03 1-133 1.66E+04 1-134 1.17E+03 1-135 4.92E+03 Cs-134 6.51E+05 Cs-136 6.51E+04 Cs-137 9.07E+05 Cs-138 6.33E+02 Ba-139 1.84E+OO Ba-140 7.40E+04 Ba-141 1.96E-01 Ba-142 5.00E-02 La-140 6.44E+02 La-142 1.30E+OO Ce-141 3.92E+04 Ce-143 3.66E+02 Ce-144 6.77E+06 Pr-143 1.85E+04 Pr-144 5.96E-02 Nd-147 1.08E+04 W-187 1.63E+01 Np-239 4.66E+02 Notes:

CY-BY-170-301 Revision 15 Page 130 of 188 Table 4-11 (Continued)

Child Inhalation Dose Factors Liver T Body Thyroid Kidney Lung 2.33E+03 9.14E+02 1.92E+03 O.OOE+OO 4.77E+05 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 9.51 E-01 6.11 E-01 1.96E+OO 7.07E+OO 1.00E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 2.72E+02 2.63E+02 3.17E+02 1.77E+03 3.77E+05 1.64E+04 8.44E+03 1.85E+06 2.45E+04 O.OOE+OO 4.81 E+04 2.73E+04 1.62E+07 7.88E+04 O.OOE+OO 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+OO 2.03E+04 7.70E+03 3.85E+06 3.38E+04 O.OOE+OO 2.16E+03 9.95E+02 5.07E+04 3.30E+03 O.OOE+OO 8.73E+03 4.14E+03 7.92E+05 1.34E+04 O.OOE+OO 1.01 E+06 2.25E+05 O.OOE+OO 3.30E+05 1.21E+05 1.71 E+05 1.16E+05 O.OOE+OO 9.55E+04 1.45E+04 8.25E+05 1.28E+05 O.OOE+OO 2.82E+05 1.04E+05 8.40E+02 5.55E+02 O.OOE+OO 6.22E+02 6.81 E+01 9.84E-04 5.37E-02 O.OOE+OO 8.62E-04 5.77E+03 6.48E+01 4.33E+03 O.OOE+OO 2.11E+01 1.74E+06 1.09E-04 6.36E-03 O.OOE+OO 9.47E-05 2.92E+03 3.60E-05 2.79E-03 O.OOE+OO 2.91 E-05 1.64E+03 2.25E+02 7.55E+01 O.OOE+OO O.OOE+OO 1.83E+05 4.11 E-01 1.29E-01 O.OOE+OO O.OOE+OO 8.70E+03 1.95E+04 2.90E+03 O.OOE+OO 8.55E+03 5.44E+05 1.99E+02 2.87E+01 O.OOE+OO 8.36E+01 1.15E+05 2.12E+06 3.61 E+05 O.OOE+OO 1.17E+06 1.20E+07 5.55E+03 9.14E+02 O.OOE+OO 3.00E+03 4.33E+05 1.85E-02 3.00E-03 O.OOE+OO 9.77E-03 1.57E+03 8.73E+03 6.81 E+02 O.OOE+OO 4.81E+03 3.28E+05 9.66E+OO 4.33E+OO O.OOE+OO O.OOE+OO 4.11E+04 3.01 E+02 2.35E+01 O.OOE+OO 9.73E+01 5.81 E+04

1)

Units are mrem/yr per µCi/m3.

GI-LLI 3.38E+04 7.14E+04 5.62E+04 1.82E+05 2.55E+04 3.08E+05 1.33E+03 1.38E+05 5.11E+03 2.84E+03 3.20E+03 5.48E+03 9.55E+02 4.44E+03 3.85E+03 4.18E+03 3.62E+03 2.70E+02 5.77E+04 1.02E+05 2.75E+02 2.74E+OO 2.26E+05 7.59E+04 5.66E+04 1.27E+05 3.89E+05 9.73E+04 1.97E+02 8.21E+04 9.10E+04 6.40E+04

N l"d UCI e 8 one H-3 O.OOE+OO C-14 2.65E+04 Na-24 1.06E+04 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 1.97E+04 Fe-59 1.36E+04 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 3.39E+05 Ni-65 2.39E+OO Cu-64 O.OOE+OO Zn-65 1.93E+04 Zn-69 5.39E-02 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 3.98E+05 Sr-90 1.55E+07 Sr-91 9.56E+01 Sr-92 1.05E+01 Y-90 3.29E+03 Y-91M 4.07E-01 Y-91 5.88E+05 Y-92 1.64E+01 Y-93 1.50E+02 Zr-95 1.15E+05 Zr-97 1.50E+02 Nb-95 1.57E+04 Mo-99 O.OOE+OO Tc-99M 1.40E-03 Tc-101 6.51E-05 Ru-103 2.02E+03 Ru-105 1.22E+OO Ru-106 8.68E+04 Ag-110M 9.98E+03 Table 4-12 CY-BY-170-301 Revision 15 Page 131 of 188 Infant Inhalation Dose Factors L"

T 8 d Th "d

K"d 1ver 0 ly 1yro1 1 ney L ung GILLI 3.68E+02 3.68E+02 3.68E+02 3.68E+02 3.68E+02 3.68E+02 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 O.OOE+OO 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 2.53E+04 4.98E+03 O.OOE+OO 4.98E+03 1.00E+06 7.06E+03 1.54E+OO 2.21 E-01 O.OOE+OO 1.10E+OO 1.25E+04 7.17E+04 1.17E+04 3.33E+03 O.OOE+OO O.OOE+OO 8.69E+04 1.09E+03 2.35E+04 9.48E+03 O.OOE+OO O.OOE+OO 1.02E+06 2.48E+04 1.22E+03 1.82E+03 O.OOE+OO O.OOE+OO 7.77E+05 1.11 E+04 8.02E+03 1.18E+04 O.OOE+OO O.OOE+OO 4.51E+06 3.19E+04 2.04E+04 1.16E+04 O.OOE+OO O.OOE+OO 2.09E+05 2.42E+03 2.84E-01 1.23E-01 O.OOE+OO O.OOE+OO 8.12E+03 5.01E+04 1.88E+OO 7.74E-01 O.OOE+OO 3.98E+OO 9.30E+03 1.50E+04 6.26E+04 3.11E+04 O.OOE+OO 3.25E+04 6.47E+05 5.14E+04 9.67E-02 7.18E-03 O.OOE+OO 4.02E-02 1.47E+03 1.32E+04 O.OOE+OO 3.81 E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.00E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.04E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.04E+03 5.57E+02 2.87E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.39E+02 3.21 E+02 2.06E+02 O.OOE+OO O.OOE+OO O.OOE+OO 6.82E+01 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 2.03E+06 6.40E+04 O.OOE+OO 3.12E+05 O.OOE+OO O.OOE+OO 1.12E+07 1.31 E+OS O.OOE+OO 3.46E+OO O.OOE+OO O.OOE+OO 5.26E+04 7.34E+04 O.OOE+OO 3.91 E-01 O.OOE+OO O.OOE+OO 2.38E+04 1.40E+05 O.OOE+OO 8.82E+01 O.OOE+OO O.OOE+OO 2.69E+05 1.04E+05 O.OOE+OO 1.39E-02 O.OOE+OO O.OOE+OO 2.79E+03 2.35E+03 O.OOE+OO 1.57E+04 O.OOE+OO O.OOE+OO 2.45E+06 7.03E+04 O.OOE+OO 4.61 E-01 O.OOE+OO O.OOE+OO 2.45E+04 1.27E+05 O.OOE+OO 4.07E+OO O.OOE+OO O.OOE+OO 7.64E+04 1.67E+05 2.79E+04 2.03E+04 O.OOE+OO 3.11E+04 1.75E+06 2.17E+04 2.56E+01 1.17E+01 O.OOE+OO 2.59E+01 1.10E+05 1.40E+05 6.43E+03 3.78E+03 O.OOE+OO 4.72E+03 4.79E+05 1.27E+04 1.65E+02 3.23E+01 O.OOE+OO 2.65E+02 1.35E+05 4.87E+04 2.88E-03 3.72E-02 O.OOE+OO 3.11 E-02 8.11 E+02 2.03E+03 8.23E-05 8.12E-04 O.OOE+OO 9.79E-04 5.84E+02 8.44E+02 O.OOE+OO 6.79E+02 O.OOE+OO 4.24E+03 5.52E+05 1.61E+04 O.OOE+OO 4.10E-01 O.OOE+OO 8.99E-01 1.57E+04 4.84E+04 O.OOE+OO 1.09E+04 O.OOE+OO 1.07E+05 1.16E+07 1.64E+05 7.22E+03 5.00E+03 O.OOE+OO 1.09E+04 3.67E+06 3.30E+04

Nuclide Bone Te-125M 4.76E+03 Te-127M 1.67E+04 Te-127 2.23E+OO Te-129M 1.41 E+04 Te-129 7.88E-02 Te-131M 1.07E+02 Te-131 1.74E-02 Te-132 3.72E+02 1-130 6.36E+03 1-131 3.79E+04 1-132 1.69E+03 1-133 1.32E+04 1-134 9.21 E+02 1-135 3.86E+03 Cs-134 3.96E+05 Cs-136 4.83E+04 Cs-137 5.49E+05 Cs-138 5.05E+02 Ba-139 1.48E+OO Ba-140 5.60E+04 Ba-141 1.57E-01 Ba-142 3.98E-02 La-140 5.05E+02 La-142 1.03E+OO Ce-141 2.77E+04 Ce-143 2.93E+02 Ce-144 3.19E+06 Pr-143 1.40E+04 Pr-144 4.79E-02 Nd-147 7.94E+03 W-187 1.30E+01 Np-239 3.71 E+02 Notes:

CY-BY-170-301 Revision 15 Page 132 of 188 Table 4-12 (Continued)

Infant Inhalation Dose Factors Liver T Body Thyroid Kidney Lung GI-LLI 1.99E+03 6.58E+02 1.62E+03 O.OOE+OO 4.47E+05 1.29E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31 E+06 2.73E+04 9.53E-01 4.89E-01 1.85E+OO 4.86E+OO 1.03E+04 2.44E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 2.37E+02 1.76E+02 2.79E+02 1.03E+03 3.40E+05 4.41E+04 1.39E+04 5.57E+03 1.60E+06 1.53E+04 O.OOE+OO 1.99E+03 4.44E+04 1.96E+04 1.48E+07 5.18E+04 O.OOE+OO 1.06E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 O.OOE+OO 1.90E+03 1.92E+04 5.60E+03 3.56E+06 2.24E+04 O.OOE+OO 2.16E+03 1.88E+03 6.65E+02 4.45E+04 2.09E+03 O.OOE+OO 1.29E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 O.OOE+OO 1.83E+03 7.03E+05 7.45E+04 O.OOE+OO 1.90E+05 7.97E+04 1.33E+03 1.35E+05 5.29E+04 O.OOE+OO 5.64E+04 1.18E+04 1.43E+03 6.12E+05 4.55E+04 O.OOE+OO 1.72E+05 7.13E+04 1.33E+03 7.81 E+02 3.98E+02 O.OOE+OO 4.10E+02 6.54E+01 8.76E+02 9.84E-04 4.30E-02 O.OOE+OO 5.92E-04 5.95E+03 5.10E+04 5.60E+01 2.90E+03 O.OOE+OO 1.34E+01 1.60E+06 3.84E+04 1.08E-04 4.97E-03 O.OOE+OO 6.50E-05 2.97E+03 4.75E+03 3.30E-05 1.96E-03 O.OOE+OO 1.90E-05 1.55E+03 6.93E+02 2.00E+02 5.15E+01 O.OOE+OO O.OOE+OO 1.68E+05 8.48E+04 3.77E-01 9.04E-02 O.OOE+OO O.OOE+OO 8.22E+03 5.95E+04 1.67E+04 1.99E+03 O.OOE+OO 5.25E+03 5.17E+05 2.16E+04 1.93E+02 2.21E+01 O.OOE+OO 5.64E+01 1.16E+05 4.97E+04 1.21 E+06 1.76E+05 O.OOE+OO 5.38E+05 9.84E+06 1.48E+05 5.24E+03 6.99E+02 O.OOE+OO 1.97E+03 4.33E+05 3.72E+04 1.85E-02 2.41 E-03 O.OOE+OO 6.72E-03 1.61E+03 4.28E+03 8.13E+03 5.00E+02 O.OOE+OO 3.15E+03 3.22E+05 3.12E+04 9.02E+OO 3.12E+OO O.OOE+OO O.OOE+OO 3.96E+04 3.56E+04 2.98E+02 1.88E+01 O.OOE+OO 6.62E+01 5.95E+04 2.49E+04

1)

Units are mrem/yr per µCi/m3*

N l"d UCI e B one H-3 O.OOE+OO C-14 8.97E+05 Na-24 2.69E+05 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 2.10E+08 Fe-59 1.26E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.04E+10 Ni-65 5.97E+01 Cu-64 O.OOE+OO Zn-65 3.17E+08 Zn-69 4.95E-06 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 9.95E+09 Sr-90 6.95E+11 Sr-91 3.01E+05 Sr-92 4.12E+02 Y-90 1.33E+04 Y-91M 4.93E-09 Y-91 5.12E+06 Y-92 8.95E-01 Y-93 1.67E+02 Zr-95 1.18E+06 Zr-97 3.35E+02 Nb-95 1.43E+05 Mo-99 O.OOE+OO Tc-99M 3.06E+OO Tc-101 O.OOE+OO Ru-103 4.77E+06 Ru-105 5.27E+01 Ru-106 1.93E+08 Ag-110M 1.05E+07 Table 4-13 CY-BY-170-301 Revision 15 Page 133 of 188 Adult Vegetation Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung GILLI 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 O.OOE+OO 4.64E+04 2.77E+04 1.02E+04 6.15E+04 1.17E+07 3.13E+08 5.97E+07 O.OOE+OO 9.31 E+07 O.OOE+OO 9.58E+08 1.54E+01 2.73E+OO O.OOE+OO 1.95E+01 O.OOE+OO 4.91E+02 1.45E+08 3.38E+07 O.OOE+OO O.OOE+OO 8.08E+07 8.31 E+07 2.96E+08 1.13E+08 O.OOE+OO O.OOE+OO 8.27E+07 9.87E+08 3.08E+07 6.90E+07 O.OOE+OO O.OOE+OO O.OOE+OO 6.24E+08 1.67E+08 3.69E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.14E+09 7.21E+08 3.49E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.50E+08 7.75E+OO 3.54E+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.97E+02 9.09E+03 4.27E+03 O.OOE+OO 2.29E+04 O.OOE+OO 7.75E+05 1.01E+09 4.56E+08 O.OOE+OO 6.75E+08 O.OOE+OO 6.36E+08 9.48E-06 6.59E-07 O.OOE+OO 6.16E-06 O.OOE+OO 1.42E-06 O.OOE+OO 3.00E+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.32E+OO O.OOE+OO 2.20E-11 O.OOE+OO O.OOE+OO O.OOE+OO 1.72E-16 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.20E+08 1.03E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.34E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.86E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.60E+09 O.OOE+OO 1.40E+10 O.OOE+OO O.OOE+OO O.OOE+OO 1.75E+10 O.OOE+OO 1.22E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.43E+06 O.OOE+OO 1.78E+01 O.OOE+OO O.OOE+OO O.OOE+OO 8.17E+03 O.OOE+OO 3.57E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.41 E+08 O.OOE+OO 1.91E-10 O.OOE+OO O.OOE+OO O.OOE+OO 1.45E-08 O.OOE+OO 1.37E+05 O.OOE+OO O.OOE+OO O.OOE+OO 2.82E+09 O.OOE+OO 2.62E-02 O.OOE+OO O.OOE+OO O.OOE+OO 1.57E+04 O.OOE+OO 4.62E+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.31 E+06 3.77E+05 2.55E+05 O.OOE+OO 5.92E+05 O.OOE+OO 1.20E+09 6.77E+01 3.09E+01 O.OOE+OO 1.02E+02 O.OOE+OO 2.10E+07 7.95E+04 4.27E+04 O.OOE+OO 7.86E+04 O.OOE+OO 4.83E+08 6.14E+06 1.17E+06 O.OOE+OO 1.39E+07 O.OOE+OO 1.42E+07 8.64E+OO 1.10E+02 O.OOE+OO 1.31 E+02 4.23E+OO 5.11 E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.05E+06 O.OOE+OO 1.82E+07 O.OOE+OO 5.57E+08 O.OOE+OO 2.08E+01 O.OOE+OO 6.81 E+02 O.OOE+OO 3.23E+04 O.OOE+OO 2.44E+07 O.OOE+OO 3.72E+08 O.OOE+OO 1.25E+10 9.75E+06 5.79E+06 O.OOE+OO 1.92E+07 O.OOE+OO 3.98E+09

Nuclide Bone Te-125M 9.67E+07 Te-127M 3.49E+08 Te-127 5.68E+03 Te-129M 2.51 E+08 Te-129 7.14E-04 Te-131M 9.09E+05 Te-131 1.26E-15 Te-132 4.28E+06 1-130 3.89E+05 1-131 8.07E+07 1-132 5.58E+01 1-133 2.08E+06 1-134 8.55E-05 1-135 3.87E+04 Cs-134 4.67E+09 Cs-136 4.25E+07 Cs-137 6.36E+09 Cs-138 3.32E-11 Ba-139 2.71 E-02 Ba-140 1.29E+08 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 1.98E+03 La-142 1.94E-04 Ce-141 1.97E+05 Ce-143 9.94E+02 Ce-144 3.29E+07 Pr-143 6.27E+04 Pr-144 O.OOE+OO Nd-147 3.37E+04 W-187 3.79E+04 Np-239 1.42E+03 Notes:

CY-BY-170-301 Revision 15 Page 134 of 188 Table 4-13 (Continued)

Adult Vegetation Dose Factors Liver T Body Thyroid Kidney Lung GI-LLI 3.50E+07 1.30E+07 2.91E+07 3.93E+08 O.OOE+OO 3.86E+08 1.25E+08 4.26E+07 8.92E+07 1.42E+09 O.OOE+OO 1.17E+09 2.04E+03 1.23E+03 4.21 E+03 2.31E+04 O.OOE+OO 4.48E+05 9.37E+07 3.97E+07 8.62E+07 1.05E+09 O.OOE+OO 1.26E+09 2.68E-04 1.74E-04 5.48E-04 3.00E-03 O.OOE+OO 5.39E-04 4.45E+05 3.71 E+05 7.04E+05 4.50E+06 O.OOE+OO 4.41 E+07 5.26E-16 3.97E-16 1.03E-15 5.51E-15 O.OOE+OO 1.78E-16 2.77E+06 2.60E+06 3.06E+06 2.67E+07 O.OOE+OO 1.31 E+08 1.15E+06 4.52E+05 9.72E+07 1.79E+06 O.OOE+OO 9.87E+05 1.15E+08 6.62E+07 3.78E+10 1.98E+08 O.OOE+OO 3.05E+07 1.49E+02 5.22E+01 5.22E+03 2.38E+02 O.OOE+OO 2.80E+01 3.62E+06 1.10E+06 5.32E+08 6.31 E+06 O.OOE+OO 3.25E+06 2.32E-04 8.31 E-05 4.02E-03 3.69E-04 O.OOE+OO 2.02E-07 1.01 E+05 3.74E+04 6.68E+06 1.62E+05 O.OOE+OO 1.14E+05 1.11E+10 9.08E+09 O.OOE+OO 3.59E+09 1.19E+09 1.94E+08 1.68E+08 1.21E+08 O.OOE+OO 9.33E+07 1.28E+07 1.90E+07 8.70E+09 5.70E+09 O.OOE+OO 2.95E+09 9.81E+08 1.68E+08 6.56E-11 3.25E-11 O.OOE+OO 4.82E-11 4.76E-12 2.80E-16 1.93E-05 7.92E-04 O.OOE+OO 1.80E-05 1.09E-05 4.80E-02 1.61E+05 8.42E+06 O.OOE+OO 5.49E+04 9.24E+04 2.65E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.97E+02 2.63E+02 O.OOE+OO O.OOE+OO O.OOE+OO 7.32E+07 8.83E-05 2.20E-05 O.OOE+OO O.OOE+OO O.OOE+OO 6.45E-01 1.33E+05 1.51E+04 O.OOE+OO 6.19E+04 O.OOE+OO 5.09E+08 7.35E+05 8.13E+01 O.OOE+OO 3.24E+02 O.OOE+OO 2.75E+07 1.38E+07 1.77E+06 O.OOE+OO 8.16E+06 O.OOE+OO 1.11E+10 2.51E+04 3.11E+03 O.OOE+OO 1.45E+04 O.OOE+OO 2.75E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.90E+04 2.33E+03 O.OOE+OO 2.28E+04 O.OOE+OO 1.87E+08 3.17E+04 1.11E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+07 1.40E+02 7.72E+01 O.OOE+OO 4.37E+02 O.OOE+OO 2.87E+07

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

N l"d UCI e B one H-3 O.OOE+OO C-14 1.45E+06 Na-24 2.39E+05 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 3.26E+08 Fe-59 1.79E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.61E+10 Ni-65 5.55E+01 Cu-64 O.OOE+OO Zn-65 4.24E+08 Zn-69 4.64E-06 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 1.51E+10 Sr-90 9.22E+11 Sr-91 2.81 E+05 Sr-92 3.84E+02 Y-90 1.24E+04 Y-91M 4.59E-09 Y-91 7.84E+06 Y-92 8.41 E-01 Y-93 1.57E+02 Zr-95 1.72E+06 Zr-97 3.10E+02 Nb-95 1.93E+05 Mo-99 O.OOE+OO Tc-99M 2.70E+OO Tc-101 O.OOE+OO Ru-103 6.82E+06 Ru-105 4.90E+01 Ru-106 3.09E+08 Ag-110M 1.52E+07 Table 4-14 CY-BY-170-301 Revision 15 Page 135 of 188 Teen Vegetation Dose Factors L"

T B d Th "d

K"d 1ver O IY 1yro1 1 ney L ung GILLI 1.47E+03 1.47E+03 1.47E+03 1.47E+03 1.47E+03 1.47E+03 2.91 E+05 2.91E+05 2.91E+05 2.91 E+05 2.91E+05 2.91E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 O.OOE+OO 6.16E+04 3.42E+04 1.35E+04 8.79E+04 1.03E+07 4.54E+08 9.01E+07 O.OOE+OO 1.36E+08 O.OOE+OO 9.32E+08 1.39E+01 2.47E+OO O.OOE+OO 1.76E+01 O.OOE+OO 9.13E+02 2.31 E+08 5.39E+07 O.OOE+OO O.OOE+OO 1.47E+08 1.00E+08 4.18E+08 1.61E+08 O.OOE+OO O.OOE+OO 1.32E+08 9.89E+08 4.37E+07 1.01E+08 O.OOE+OO O.OOE+OO O.OOE+OO 6.02E+08 2.49E+08 5.60E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.24E+09 1.13E+09 5.45E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.81 E+08 7.10E+OO 3.23E+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.85E+02 8.24E+03 3.87E+03 O.OOE+OO 2.08E+04 O.OOE+OO 6.39E+05 1.47E+09 6.86E+08 O.OOE+OO 9.41E+08 O.OOE+OO 6.23E+08 8.84E-06 6.19E-07 O.OOE+OO 5.78E-06 O.OOE+OO 1.63E-05 O.OOE+OO 2.81 E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.00E-11 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.75E+08 1.29E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.06E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.33E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.80E+09 O.OOE+OO 1.84E+10 O.OOE+OO O.OOE+OO O.OOE+OO 2.11E+10 O.OOE+OO 1.12E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.27E+06 O.OOE+OO 1.64E+01 O.OOE+OO O.OOE+OO O.OOE+OO 9.78E+03 O.OOE+OO 3.35E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.02E+08 O.OOE+OO 1.75E-10 O.OOE+OO O.OOE+OO O.OOE+OO 2.17E-07 O.OOE+OO 2.10E+05 O.OOE+OO O.OOE+OO O.OOE+OO 3.21E+09 O.OOE+OO 2.43E-02 O.OOE+OO O.OOE+OO O.OOE+OO 2.31E+04 O.OOE+OO 4.30E+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.80E+06 5.44E+05 3.74E+05 O.OOE+OO 7.99E+05 O.OOE+OO 1.26E+09 6.14E+01 2.83E+01 O.OOE+OO 9.31 E+01 O.OOE+OO 1.66E+07 1.07E+05 5.90E+04 O.OOE+OO 1.04E+05 O.OOE+OO 4.58E+08 5.63E+06 1.07E+06 O.OOE+OO 1.29E+07 O.OOE+OO 1.01E+07 7.52E+OO 9.75E+01 O.OOE+OO 1.12E+02 4.17E+OO 4.94E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.91E+06 O.OOE+OO 2.40E+07 O.OOE+OO 5.69E+08 O.OOE+OO 1.90E+01 O.OOE+OO 6.18E+02 O.OOE+OO 3.95E+04 O.OOE+OO 3.90E+07 O.OOE+OO 5.97E+08 O.OOE+OO 1.48E+10 1.44E+07 8.73E+06 O.OOE+OO 2.74E+07 O.OOE+OO 4.03E+09

Nuclide Bone Te-125M 1.49E+08 Te-127M 5.51E+08 Te-127 5.36E+03 Te-129M 3.61E+08 Te-129 6.68E-04 Te-131M 8.42E+05 Te-131 1.17E-15 Te-132 3.89E+06 1-130 3.47E+05 1-131 7.68E+07 1-132 5.03E+01 1-133 1.93E+06 1-134 7.73E-05 1-135 3.49E+04 Cs-134 7.10E+09 Cs-136 4.35E+07 Cs-137 1.01E+10 Cs-138 3.07E-11 Ba-139 2.55E-02 Ba-140 1.38E+08 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 1.81 E+03 La-142 1.78E-04 Ce-141 2.83E+05 Ce-143 9.29E+02 Ce-144 5.27E+07 Pr-143 7.01E+04 Pr-144 O.OOE+OO Nd-147 3.67E+04 W-187 3.53E+04 Np-239 1.38E+03 Notes:

CY-BY-170-301 Revision 15 Page 136 of 188 Table 4-14 (Continued)

Teen Vegetation Dose Factors Liver T Body Thyroid Kidney Lung GI-LLI 5.35E+07 1.99E+07 4:15E+07 O.OOE+OO O.OOE+OO 4.38E+08 1.96E+08 6.56E+07 1.31E+08 2.24E+09 O.OOE+OO 1.37E+09 1.90E+03 1.15E+03 3.70E+03 2.17E+04 O.OOE+OO 4.14E+05 1.34E+08 5.72E+07 1.17E+08 1.51E+09 O.OOE+OO 1.36E+09 2.49E-04 1.63E-04 4.77E-04 2.80E-03 O.OOE+OO 3.65E-03 4.04E+05 3.37E+05 6.07E+05 4.21E+06 O.OOE+OO 3.24E+07 4.82E-16 3.66E-16 9.01E-16 5.11E-15 O.OOE+OO 9.60E-17 2.46E+06 2.32E+06 2.60E+06 2.36E+07 O.OOE+OO 7.81E+07 1.01E+06 4.01E+05 8.20E+07 1.55E+06 O.OOE+OO 7.73E+05 1.08E+08 5.78E+07 3.14E+10 1.85E+08 O.OOE+OO 2.13E+07 1.32E+02 4.72E+01 4.43E+03 2.07E+02 O.OOE+OO 5.73E+01 3.28E+06 1.00E+06 4.58E+08 5.75E+06 O.OOE+OO 2.48E+06 2.05E-04 7.36E-05 3.41 E-03 3.23E-04 O.OOE+OO 2.70E-06 8.99E+04 3.33E+04 5.78E+06 1.42E+05 O.OOE+OO 9.97E+04 1.67E+10 7.75E+09 O.OOE+OO 5.31 E+09 2.03E+09 2.08E+08 1.71 E+08 1.15E+08 O.OOE+OO 9.31 E+07 1.47E+07 1.38E+07 1.35E+10 4.69E+09 O.OOE+OO 4.59E+09 1.78E+09 1.92E+08 5.89E-11 2.94E-11 O.OOE+OO 4.35E-11 5.06E-12 2.67E-14 1.79E-05 7.42E-04 O.OOE+OO 1.69E-05 1.23E-05 2.27E-01 1.69E+05 8.90E+06 O.OOE+OO 5.74E+04 1.14E+05 2.13E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.88E+02 2.36E+02 O.OOE+OO O.OOE+OO O.OOE+OO 5.10E+07 7.92E-05 1.97E-05 O.OOE+OO O.OOE+OO O.OOE+OO 2.41 E+OO 1.89E+05 2.17E+04 O.OOE+OO 8.89E+04 O.OOE+OO 5.40E+08 6.76E+05 7.55E+01 O.OOE+OO 3.03E+02 O.OOE+OO 2.03E+07 2.18E+07 2.83E+06 O.OOE+OO 1.30E+07 O.OOE+OO 1.33E+10 2.80E+04 3.49E+03 O.OOE+OO 1.63E+04 O.OOE+OO 2.31E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.00E+04 2.39E+03 O.OOE+OO 2.35E+04 O.OOE+OO 1.44E+08 2.87E+04 1.01 E+04 O.OOE+OO O.OOE+OO O.OOE+OO 7.78E+06 1.30E+02 7.24E+01 O.OOE+OO 4.09E+02 O.OOE+OO 2.10E+07

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

N l"d UCI e B one H-3 O.OOE+OO C-14 3.50E+06 Na-24 3.73E+05 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 8.01 E+08 Fe-59 3.97E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 3.95E+10 Ni-65 1.02E+02 Cu-64 O.OOE+OO Zn-65 8.12E+08 Zn-69 8.56E-06 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 3.59E+10 Sr-90 1.87E+12 Sr-91 5.17E+05 Sr-92 7.04E+02 Y-90 2.31 E+04 Y-91M 8.42E-09 Y-91 1.87E+07 Y-92 1.55E+OO Y-93 2.89E+02 Zr-95 3.86E+06 Zr-97 5.67E+02 Nb-95 4.12E+05 Mo-99 O.OOE+OO Tc-99M 4.64E+OO Tc-101 O.OOE+OO Ru-103 1.53E+07 Ru-105 8.97E+01 Ru-106 7.45E+08 Ag-110M 3.21 E+07 Table 4-15 CY-BY-170-301 Revision 15 Page 137 of 188 Child Vegetation Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung 2.29E+03 2.29E+03 2.29E+03 2.29E+03 2.29E+03 7.01E+05 7.01 E+05 7.01 E+05 7.01 E+05 7.01 E+05 3.73E+05 3.73E+05 3.73E+05 3.73E+05 3.73E+05 O.OOE+OO 1.17E+05 6.49E+04 1.77E+04 1.18E+05 6.65E+08 1.77E+08 O.OOE+OO 1.86E+08 O.OOE+OO 1.82E+01 4.10E+OO O.OOE+OO 2.20E+01 O.OOE+OO 4.25E+08 1.32E+08 O.OOE+OO O.OOE+OO 2.40E+08 6.42E+08 3.20E+08 O.OOE+OO O.OOE+OO 1.86E+08 6.45E+07 1.97E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.78E+08 1.12E+09 O.OOE+OO O.OOE+OO O.OOE+OO 2.11E+09 1.34E+09 O.OOE+OO O.OOE+OO O.OOE+OO 9.59E+OO 5.60E+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.09E+04 6.56E+03 O.OOE+OO 2.62E+04 O.OOE+OO 2.16E+09 1.35E+09 O.OOE+OO 1.36E+09 O.OOE+OO 1.24E-05 1.14E-06 O.OOE+OO 7.SOE-06 O.OOE+OO O.OOE+OO 5.18E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.39E-11 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.54E+08 2.79E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.03E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.77E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.95E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.82E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.18E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.06E-10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.99E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.43E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.94E+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.50E+05 7.56E+05 O.OOE+OO 1.22E+06 O.OOE+OO 8.19E+01 4.83E+01 O.OOE+OO 1.18E+02 O.OOE+OO 1.61 E+05 1.15E+05 O.OOE+OO 1.51 E+OS O.OOE+OO 7.69E+06 1.90E+06 O.OOE+OO 1.64E+07 O.OOE+OO 9.10E+OO 1.51E+02 O.OOE+OO 1.32E+02 4.62E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.89E+06 O.OOE+OO 3.86E+07 O.OOE+OO O.OOE+OO 3.25E+01 O.OOE+OO 7.89E+02 O.OOE+OO O.OOE+OO 9.30E+07 O.OOE+OO 1.01 E+09 O.OOE+OO 2.17E+07 1.74E+07 O.OOE+OO 4.04E+07 O.OOE+OO GILLI 2.29E+03 7.01E+05 3.73E+05 6.20E+06 5.58E+08 2.63E+03 7.87E+07 6.69E+08 3.76E+08 2.10E+09 1.42E+08 1.18E+03 5.10E+05 3.80E+08 7.80E-04 O.OOE+OO O.OOE+OO O.OOE+OO 2.92E+07 O.OOE+OO O.OOE+OO 1.39E+09 1.67E+10 1.14E+06 1.33E+04 6.57E+07 1.65E-05 2.49E+09 4.47E+04 4.31 E+06 8.86E+08 1.24E+07 2.97E+08 6.36E+06 5.18E+03 O.OOE+OO 3.96E+08 5.86E+04 1.16E+10 2.58E+09

CY-BY-170-301 Revision 15 Page 138 of 188 Table 4-15 (Continued)

Child Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung Te-125M 3.51E+08 9.52E+07 4.68E+07 9.86E+07 O.OOE+OO O.OOE+OO Te-127M 1.32E+09 3.56E+08 1.57E+08 3.16E+08 3.77E+09 O.OOE+OO Te-127 9.89E+03 2.67E+03 2.12E+03 6.84E+03 2.81 E+04 O.OOE+OO Te-129M 8.40E+08 2.35E+08 1.30E+08 2.71 E+08 2.47E+09 O.OOE+OO Te-129 1.24E-03 3.45E-04 2.94E-04 8.83E-04 3.62E-03 O.OOE+OO Te-131M 1.54E+06 5.32E+05 5.66E+05 1.09E+06 5.15E+06 O.OOE+OO Te-131 2.15E-15 6.57E-16 6.41 E-16 1.65E-15 6.51 E-15 O.OOE+OO Te-132 6.97E+06 3.09E+06 3.73E+06 4.49E+06 2.86E+07 O.OOE+OO 1-130 6.10E+05 1.23E+06 6.35E+05 1.36E+08 1.84E+06 O.OOE+OO 1-131 1.43E+08 1.44E+08 8.17E+07 4.75E+10 2.36E+08 O.OOE+OO 1-132 8.93E+01 1.64E+02 7.54E+01 7.61 E+03 2.51E+02 O.OOE+OO 1-133 3.52E+06 4.36E+06 1.65E+06 8.09E+08 7.26E+06 O.OOE+OO 1-134 1.37E-04 2.55E-04 1.17E-04 5.86E-03 3.90E-04 O.OOE+OO 1-135 6.20E+04 1.12E+05 5.28E+04 9.89E+06 1.71E+05 O.OOE+OO Cs-134 1.60E+10 2.63E+10 5.55E+09 O.OOE+OO 8.16E+09 2.93E+09 Cs-136 8.18E+07 2.25E+08 1.46E+08 O.OOE+OO 1.20E+08 1.79E+07 Cs-137 2.39E+10 2.29E+10 3.38E+09 O.OOE+OO 7.46E+09 2.68E+09 Cs-138 5.58E-11 7.75E-11 4.92E-11 O.OOE+OO 5.45E-11 5.87E-12 Ba-139 4.69E-02 2.51E-05 1.36E-03 O.OOE+OO 2.19E-05 1.47E-05 Ba-140 2.77E+08 2.43E+05 1.62E+07 O.OOE+OO 7.90E+04 1.45E+05 Ba-141 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Ba-142 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO La-140 3.25E+03 1.13E+03 3.82E+02 O.OOE+OO O.OOE+OO O.OOE+OO La-142 3.23E-04 1.03E-04 3.22E-05 O.OOE+OO O.OOE+OO O.OOE+OO Ce-141 6.55E+05 3.27E+05 4.85E+04 O.OOE+OO 1.43E+05 O.OOE+OO Ce-143 1.71 E+03 9.28E+05 1.34E+02 O.OOE+OO 3.89E+02 O.OOE+OO Ce-144 1.27E+08 3.98E+07 6.78E+06 O.OOE+OO 2.21E+07 O.OOE+OO Pr-143 1.46E+05 4.38E+04 7.24E+03 O.OOE+OO 2.37E+04 O.OOE+OO Pr-144 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Nd-147 7.27E+04 5.89E+04 4.56E+03 O.OOE+OO 3.23E+04 O.OOE+OO W-187 6.41E+04 3.80E+04 1.70E+04 O.OOE+OO O.OOE+OO O.OOE+OO Np-239 2.55E+03 1.83E+02 1.29E+02 O.OOE+OO 5.30E+02 O.OOE+OO Notes:

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

GI-LLI 3.39E+08 1.07E+09 3.86E+05 1.02E+09 7.70E-02 2.16E+07 1.13E-14 3.11E+07 5.76E+05 1.28E+07 1.93E+02 1.76E+06 1.69E-04 8.51E+04 1.42E+08 7.90E+06 1.43E+08 3.57E-11 2.71E+OO 1.40E+08 O.OOE+OO O.OOE+OO 3.16E+07 2.04E+01 4.08E+08 1.36E+07 1.04E+10 1.57E+08 O.OOE+OO 9.33E+07 5.34E+06 1.36E+07

3)

The infant age group is assumed lo receive no dose through the vegetation ingestion pathway therefore no dose factors are supplied.

Nuclide B one H-3 O.OOE+OO C-14 3.63E+05 Na-24 2.46E+06 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 2.51E+07 Fe-59 2.97E+07 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 6.73E+09 Ni-65 3.70E-01 Cu-64 O.OOE+OO Zn-65 1.37E+09 Zn-69 2.01 E-12 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 1.45E+09 Sr-90 5.38E+10 Sr-91 2.87E+04 Sr-92 4.84E-01 Y-90 7.10E+01 Y-91M 6.42E-20 Y-91 8.59E+03 Y-92 5.57E-05 Y-93 2.22E-01 Zr-95 9.44E+02 Zr-97 4.32E-01 Nb-95 8.26E+04 Mo-99 O.OOE+OO Tc-99M 3.31 E+OO Tc-101 O.OOE+OO Ru-103 1.02E+03 Ru-105 8.51E-04 Ru-106 2.04E+04 Ag-110M 5.82E+07 Table 4-16 CY-BY-170-301 Revision 15 Page 139 of 188 Adult Grass-Cow-Milk Dose Factors L"

TB d Th "d

K"d 1ver o IY 1yro1 1 ney L ung 4.35E+02 4.35E+02 4.35E+02 4.35E+02 4.35E+02 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 2.46E+06 2.46E+06 2.46E+06 2.46E+06 2.46E+06 O.OOE+OO 2.86E+04 1.71E+04 6.29E+03 3.79E+04 8.41E+06 1.61E+06 O.OOE+OO 2.50E+06 O.OOE+OO 4.13E-03 7.32E-04 O.OOE+OO 5.24E-03 O.OOE+OO 1.74E+07 4.05E+06 O.OOE+OO O.OOE+OO 9.68E+06 6.98E+07 2.67E+07 O.OOE+OO O.OOE+OO 1.95E+07 4.72E+06 1.06E+07 O.OOE+OO O.OOE+OO O.OOE+OO 1.64E+07 3.62E+07 O.OOE+OO O.OOE+OO O.OOE+OO 4.66E+08 2.26E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.81E-02 2.19E-02 O.OOE+OO O.OOE+OO O.OOE+OO 2.36E+04 1.11 E+04 O.OOE+OO 5.95E+04 O.OOE+OO 4.36E+09 1.97E+09 O.OOE+OO 2.92E+09 O.OOE+OO 3.84E-12 2.67E-13 O.OOE+OO 2.50E-12 O.OOE+OO O.OOE+OO 9.65E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.60E+09 1.21E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.16E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.08E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.16E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.09E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.30E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.63E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.12E-03 O.OOE+OO O.OOE+OO O.OOE+OO 3.03E+02 2.05E+02 O.OOE+OO 4.75E+02 O.OOE+OO 8.72E-02 3.99E-02 O.OOE+OO 1.32E-01 O.OOE+OO 4.60E+04 2.47E+04 O.OOE+OO 4.54E+04 O.OOE+OO 2.47E+07 4.70E+06 O.OOE+OO 5.60E+07 O.OOE+OO 9.35E+OO 1.19E+02 O.OOE+OO 1.42E+02 4.58E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.39E+02 O.OOE+OO 3.88E+03 O.OOE+OO O.OOE+OO 3.36E-04 O.OOE+OO 1.10E-02 O.OOE+OO O.OOE+OO 2.58E+03 O.OOE+OO 3.94E+04 O.OOE+OO 5.39E+07 3.20E+07 O.OOE+OO 1.06E+08 O.OOE+OO GILLI 4.35E+02 7.26E+04 2.46E+06 7.18E+06 2.58E+07 1.32E-01 9.95E+06 2.33E+08 9.56E+07 3.08E+08 9.73E+07 1.22E+OO 2.01E+06 2.75E+09 5.78E-13 1.39E-01 O.OOE+OO O.OOE+OO 5.12E+08 O.OOE+OO O.OOE+OO 2.33E+08 1.35E+09 1.37E+05 9.58E+OO 7.52E+05 1.89E-19 4.73E+06 9.75E-01 7.03E+03 9.59E+05 2.70E+04 2.79E+08 5.73E+07 5.53E+03 O.OOE+OO 1.19E+05 5.20E-01 1.32E+06 2.20E+10

Nuclide Bone Te-125M 1.63E+07 Te-127M 4.58E+07 Te-127 6.66E+02 Te-129M 6.02E+07 Te-129 2.83E-10 Te-131M 3.61E+05 Te-131 O.OOE+OO Te-132 2.39E+06 1-130 4.18E+05 1-131 2.96E+08 1-132 1.65E-01 1-133 3.88E+06 1-134 1.89E-12 1-135 1.29E+04 Cs-134 5.65E+09 Cs-136 2.63E+08 Cs-137 7.38E+09 Cs-138 O.OOE+OO Ba-139 4.43E-08 Ba-140 2.69E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 4.52E+OO La-142 1.89E-11 Ce-141 4.84E+03 Ce-143 4.15E+01 Ce-144 3.58E+05 Pr-143 1.58E+02 Pr-144 O.OOE+OO Nd-147 9.48E+01 W-187 6.51E+03 Np-239 3.67E+OO Notes:

Table 4-16 (Continued)

CY-BY-170-301 Revision 15 Page 140 of 188 Adult Grass-Cow-Milk Dose Factors Liver T Body Thyroid Kidney Lung 5.91E+06 2.18E+06 4.90E+06 6.63E+07 O.OOE+OO 1.64E+07 5.58E+06 1.17E+07 1.86E+08 O.OOE+OO 2.39E+02 1.44E+02 4.94E+02 2.71 E+03 O.OOE+OO 2.24E+07 9.52E+06 2.07E+07 2.51 E+08 O.OOE+OO 1.06E-10 6.88E-11 2.17E-10 1.19E-09 O.OOE+OO 1.76E+05 1.47E+05 2.79E+05 1.79E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.55E+06 1.45E+06 1.71 E+06 1.49E+07 O.OOE+OO 1.23E+06 4.86E+05 1.04E+08 1.92E+06 O.OOE+OO 4.23E+08 2.43E+08 1.39E+11 7.26E+08 O.OOE+OO 4.40E-01 1.54E-01 1.54E+01 7.02E-01 O.OOE+OO 6.74E+06 2.06E+06 9.91E+08 1.18E+07 O.OOE+OO 5.13E-12 1.83E-12 8.89E-11 8.16E-12 O.OOE+OO 3.38E+04 1.25E+04 2.23E+06 5.42E+04 O.OOE+OO 1.35E+10 1.10E+10 O.OOE+OO 4.35E+09 1.45E+09 1.04E+09 7.46E+08 O.OOE+OO 5.77E+08 7.91 E+07 1.01 E+10 6.61E+09 O.OOE+OO 3.43E+09 1.14E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.16E-11 1.30E-09 O.OOE+OO 2.95E-11 1.79E-11 3.38E+04 1.76E+06 O.OOE+OO 1.15E+04 1.93E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.28E+OO 6.02E-01 O.OOE+OO O.OOE+OO O.OOE+OO 8.59E-12 2.14E-12 O.OOE+OO O.OOE+OO O.OOE+OO 3.28E+03 3.72E+02 O.OOE+OO 1.52E+03 O.OOE+OO 3.07E+04 3.39E+OO O.OOE+OO 1.35E+01 O.OOE+OO 1.50E+05 1.92E+04 O.OOE+OO 8.87E+04 O.OOE+OO 6.34E+01 7.83E+OO O.OOE+OO 3.66E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.10E+02 6.56E+OO O.OOE+OO 6.41 E+01 O.OOE+OO 5.44E+03 1.90E+03 O.OOE+OO O.OOE+OO O.OOE+OO 3.61 E-01 1.99E-01 O.OOE+OO 1.12E+OO O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

GI-LLI 6.51E+07 1.54E+08 5.26E+04 3.03E+08 2.13E-10 1.75E+07 O.OOE+OO 7.32E+07 1.06E+06 1.12E+08 8.27E-02 6.06E+06 4.47E-15 3.82E+04 2.35E+08 1.18E+08 1.95E+08 O.OOE+OO 7.86E-08 5.54E+07 O.OOE+OO O.OOE+OO 1.67E+05 6.28E-08 1.25E+07 1.15E+06 1.21E+08 6.92E+05 O.OOE+OO 5.26E+05 1.78E+06 7.40E+04

N l"d UCI e B one H-3 O.OOE+OO C-14 6.70E+05 Na-24 4.29E+06 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 4.45E+07 Fe-59 5.18E+07 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.18E+10 Ni-65 6.78E-01 Cu-64 O.OOE+OO Zn-65 2.11E+09 Zn-69 3.70E-12 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 2.67E+09 Sr-90 8.13E+10 Sr-91 5.27E+04 Sr-92 8.85E-01 Y-90 1.30E+02 Y-91M 1.18E-19 Y-91 1.58E+04 Y-92 1.03E-04 Y-93 4.09E-01 Zr-95 1.65E+03 Zr-97 7.87E-01 Nb-95 1.41E+05 Mo-99 O.OOE+OO Tc-99M 5.74E+OO Tc-101 O.OOE+OO Ru-103 1.81E+03 Ru-105 1.55E-03 Ru-106 3.75E+04 Ag-110M 9.63E+07 Table 4-17 CY-BY-170-301 Revision 15 Page 141 of 188 Teen Grass-Cow-Milk Dose Factors L",ver TB d O IY Th "d

K"d 1yro1 1 ney L ung 5.66E+02 5.66E+02 5.66E+02 5.66E+02 5.66E+02 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 O.OOE+OO 4.99E+04 2.77E+04 1.09E+04 7.12E+04 1.40E+07 2.78E+06 O.OOE+OO 4.18E+06 O.OOE+OO 7.32E-03 1.30E-03 O.OOE+OO 9.27E-03 O.OOE+OO 3.16E+07 7.36E+06 O.OOE+OO O.OOE+OO 2.00E+07 1.21E+08 4.67E+07 O.OOE+OO O.OOE+OO 3.81 E+07 7.94E+06 1.83E+07 O.OOE+OO O.OOE+OO O.OOE+OO 2.78E+07 6.26E+07 O.OOE+OO O.OOE+OO O.OOE+OO 8.35E+08 4.01E+08 O.OOE+OO O.OOE+OO O.OOE+OO 8.66E-02 3.94E-02 O.OOE+OO O.OOE+OO O.OOE+OO 4.21 E+04 1.98E+04 O.OOE+OO 1.06E+05 O.OOE+OO 7.31 E+09 3.41E+09 O.OOE+OO 4.68E+09 O.OOE+OO 7.0SE-12 4.94E-13 O.OOE+OO 4.61E-12 O.OOE+OO O.OOE+OO 1.78E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.73E+09 2.22E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.66E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.63E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.10E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.77E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.51E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.24E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.98E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.12E-02 O.OOE+OO O.OOE+OO O.OOE+OO 5.21E+02 3.58E+02 O.OOE+OO 7.65E+02 O.OOE+OO 1.56E-01 7.17E-02 O.OOE+OO 2.36E-01 O.OOE+OO 7.82E+04 4.30E+04 O.OOE+OO 7.58E+04 O.OOE+OO 4.46E+07 8.51E+06 O.OOE+OO 1.02E+08 O.OOE+OO 1.60E+01 2.07E+02 O.OOE+OO 2.39E+02 8.89E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.74E+02 O.OOE+OO 6.38E+03 O.OOE+OO O.OOE+OO 6.03E-04 O.OOE+OO 1.96E-02 O.OOE+OO O.OOE+OO 4.73E+03 O.OOE+OO 7.24E+04 O.OOE+OO 9.11E+07 5.54E+07 O.OOE+OO 1.74E+08 O.OOE+OO GILLI 5.66E+02 1.34E+05 4.29E+06 8.38E+06 2.87E+07 4.82E-01 1.37E+07 2.86E+08 1.09E+08 3.62E+08 1.33E+08 4.70E+OO 3.26E+06 3.10E+09 1.30E-11 O.OOE+OO O.OOE+OO O.OOE+OO 7.01E+08 O.OOE+OO O.OOE+OO 3.18E+08 1.86E+09 2.39E+05 2.26E+01 1.08E+06 5.55E-18 6.48E+06 2.82E+OO 1.25E+04 1.20E+06 4.22E+04 3.34E+08 8.00E+07 1.05E+04 O.OOE+OO 1.51E+05 1.25E+OO 1.80E+06 2.56E+10

Nuclide Bone Te-125M 3.01E+07 Te-127M 8.44E+07 Te-127 1.24E+03 Te-129M 1.10E+08 Te-129 5.20E-10 Te-131M 6.57E+05 Te-131 O.OOE+OO Te-132 4.27E+06 1-130 7.35E+05 1-131 5.37E+08 1-132 2.92E-01 1-133 7.08E+06 1-134 3.35E-12 1-135 2.29E+04 Cs-134 9.82E+09 Cs-136 4.47E+08 Cs-137 1.34E+10 Cs-138 O.OOE+OO Ba-139 8.20E-08 Ba-140 4.85E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 8.12E+OO La-142 3.41E-11 Ce-141 8.88E+03 Ce-143 7.62E+01 Ce-144 6.58E+05 Pr-143 2.90E+02 Pr-144 O.OOE+OO Nd-147 1.82E+02 W-187 1.19E+04 Np-239 7.00E+OO Notes:

Table 4-17 (Continued)

CY-BY-170-301 Revision 15 Page 142 of 188 Teen Grass-Cow-Milk Dose Factors Liver T Body Thyroid Kidney Lung 1.08E+07 4.02E+06 8.40E+06 O.OOE+OO O.OOE+OO 2.99E+07 1.00E+07 2.01E+07 3.42E+08 O.OOE+OO 4.38E+02 2.66E+02 8.52E+02 5.00E+03 O.OOE+OO 4.09E+07 1.74E+07 3.55E+07 4.61E+08 O.OOE+OO 1.94E-10 1.27E-10 3.72E-10 2.18E-09 O.OOE+OO 3.15E+05 2.63E+05 4.74E+05 3.28E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.71 E+06 2.55E+06 2.85E+06 2.60E+07 O.OOE+OO 2.13E+06 8.49E+05 1.73E+08 3.27E+06 O.OOE+OO 7.52E+08 4.04E+08 2.19E+11 1.29E+09 O.OOE+OO 7.64E-01 2.74E-01 2.57E+01 1.20E+OO O.OOE+OO 1.20E+07 3.66E+06 1.68E+09 2.11E+07 O.OOE+OO 8.89E-12 3.19E-12 1.48E-10 1.40E-11 O.OOE+OO 5.91E+04 2.19E+04 3.80E+06 9.33E+04 O.OOE+OO 2.31E+10 1.07E+10 O.OOE+OO 7.34E+09 2.80E+09 1.76E+09 1.18E+09 O.OOE+OO 9.58E+08 1.51E+08 1.78E+10 6.20E+09 O.OOE+OO 6.06E+09 2.35E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.77E-11 2.39E-09 O.OOE+OO 5.44E-11 3.98E-11 5.95E+04 3.13E+06 O.OOE+OO 2.02E+04 4.00E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.99E+OO 1.06E+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.51E-11 3.77E-12 O.OOE+OO O.OOE+OO O.OOE+OO 5.93E+03 6.81E+02 O.OOE+OO 2.79E+03 O.OOE+OO 5.55E+04 6.20E+OO O.OOE+OO 2.49E+01 O.OOE+OO 2.72E+05 3.54E+04 O.OOE+OO 1.63E+05 O.OOE+OO 1.16E+02 1.44E+01 O.OOE+OO 6.74E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+02 1.19E+01 O.OOE+OO 1.17E+02 O.OOE+OO 9.71 E+03 3.40E+03 O.OOE+OO O.OOE+OO O.OOE+OO 6.60E-01 3.67E-01 O.OOE+OO 2.07E+OO O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GI-LLI 8.87E+07 2.10E+08 9.54E+04 4.13E+08 2.84E-09 2.53E+07 O.OOE+OO 8.57E+07 1.63E+06 1.49E+08 3.33E-01 9.09E+06 1.17E-13 6.54E+04 2.87E+08 1.42E+08 2.53E+08 O.OOE+OO 7.31 E-07 7.49E+07 O.OOE+OO O.OOE+OO 2.29E+05 4.61E-07 1.70E+07 1.67E+06 1.66E+08 9.55E+05 O.OOE+OO 7.16E+05 2.63E+06 1.06E+05

N l"d UCI e B one H-3 O.OOE+OO C-14 1.65E+06 Na-24 8.93E+06 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 1.12E+08 Fe-59 1.20E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 2.96E+10 Ni-65 1.66E+OO Cu-64 O.OOE+OO Zn-65 4.13E+09 Zn-69 9.10E-12 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 6.62E+09 Sr-90 1.68E+11 Sr-91 1.29E+05 Sr-92 2.16E+OO Y-90 3.23E+02 Y-91M 2.87E-19 Y-91 3.90E+04 Y-92 2.53E-04 Y-93 1.00E+OO Zr-95 3.83E+03 Zr-97 1.91E+OO Nb-95 3.18E+05 Mo-99 O.OOE+OO Tc-99M 1.32E+01 Tc-101 O.OOE+OO Ru-103 4.28E+03 Ru-105 3.79E-03 Ru-106 9.24E+04 AQ-110M 2.09E+08 Table 4-18 CY-BY-170-301 Revision 15 Page 143 of 188 Child Grass-Cow-Milk Dose Factors L" 1ver TB d O IY Th "d

K"d 1yro1 1 ney L ung 8.97E+02 8.97E+02 8.97E+02 8.97E+02 8.97E+02 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 O.OOE+OO 1.02E+05 5.65E+04 1.54E+04 1.03E+05 2.10E+07 5.59E+06 O.OOE+OO 5.88E+06 O.OOE+OO 1.28E-02 2.88E-03 O.OOE+OO 1.54E-02 O.OOE+OO 5.93E+07 1.84E+07 O.OOE+OO O.OOE+OO 3.35E+07 1.94E+08 9.69E+07 O.OOE+OO O.OOE+OO 5.64E+07 1.21E+07 3.71 E+07 O.OOE+OO O.OOE+OO O.OOE+OO 4.32E+07 1.27E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.59E+09 1.01E+09 O.OOE+OO O.OOE+OO O.OOE+OO 1.56E-01 9.11 E-02 O.OOE+OO O.OOE+OO O.OOE+OO 7.39E+04 4.47E+04 O.OOE+OO 1.79E+05 O.OOE+OO 1.10E+10 6.85E+09 O.OOE+OO 6.94E+09 O.OOE+OO 1.32E-11 1.22E-12 O.OOE+OO 7.98E-12 O.OOE+OO O.OOE+OO 4.37E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.78E+09 5.40E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.89E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.38E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.88E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.67E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.64E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.04E-20 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.23E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.75E-02 O.OOE+OO O.OOE+OO O.OOE+OO 8.43E+02 7.50E+02 O.OOE+OO 1.21 E+03 O.OOE+OO 2.77E-01 1.63E-01 O.OOE+OO 3.97E-01 O.OOE+OO 1.24E+05 8.85E+04 O.OOE+OO 1.16E+05 O.OOE+OO 8.12E+07 2.01 E+07 O.OOE+OO 1.73E+08 O.OOE+OO 2.58E+01 4.28E+02 O.OOE+OO 3.75E+02 1.31 E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.65E+03 O.OOE+OO 1.08E+04 O.OOE+OO O.OOE+OO 1.38E-03 O.OOE+OO 3.33E-02 O.OOE+OO O.OOE+OO 1.15E+04 O.OOE+OO 1.25E+05 O.OOE+OO 1.41E+08 1.13E+08 O.OOE+OO 2.63E+08 O.OOE+OO GILLI 8.97E+02 3.29E+05 8.93E+06 5.39E+06 1.76E+07 1.85E+OO 1.10E+07 2.02E+08 7.08E+07 2.39E+08 1.07E+08 1.91 E+01 3.47E+06 1.93E+09 8.29E-10 O.OOE+OO O.OOE+OO O.OOE+OO 5.65E+08 O.OOE+OO O.OOE+OO 2.56E+08 1.51 E+09 2.86E+05 4.09E+01 9.19E+05 5.62E-16 5.20E+06 7.30E+OO 1.50E+04 8.79E+05 4.19E+04 2.29E+08 6.72E+07 1.47E+04 O.OOE+OO 1.11 E+05 2.48E+OO 1.44E+06 1.68E+10

Nuclide Bone Te-125M 7.38E+07 Te-127M 2.08E+08 Te-127 3.04E+03 Te-129M 2.71 E+08 Te-129 1.28E-09 Te-131M 1.60E+06 Te-131 O.OOE+OO Te-132 1.02E+07 1-130 1.72E+06 1-131 1.30E+09 1-132 6.91 E-01 1-133 1.72E+07 1-134 7.94E-12 1-135 5.43E+04 Cs-134 2.26E+10 Cs-136 1.01 E+09 Cs-137 3.22E+10 Cs-138 O.OOE+OO Ba-139 2.01 E-07 Ba-140 1.17E+08 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 1.95E+01 La-142 8.24E-11 Ce-141 2.19E+04 Ce-143 1.87E+02 Ce-144 1.62E+06 Pr-143 7.18E+02 Pr-144 O.OOE+OO Nd-147 4.48E+02 W-187 2.89E+04 Np-239 1.72E+01 Notes:

Table 4-18 (Continued)

CY-BY-170-301 Revision 15 Page 144 of 188 Child Grass-Cow-Milk Dose Factors Liver T Body Thyroid Kidney Lung 2.00E+07 9.84E+06 2.07E+07 O.OOE+OO O.OOE+OO 5.60E+07 2.47E+07 4.97E+07 5.93E+08 O.OOE+OO 8.19E+02 6.51E+02 2.10E+03 8.64E+03 O.OOE+OO 7.58E+07 4.21E+07 8.75E+07 7.97E+08 O.OOE+OO 3.58E-10 3.05E-10 9.16E-10 3.75E-09 O.OOE+OO 5.53E+05 5.88E+05 1.14E+06 5.35E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.52E+06 5.46E+06 6.58E+06 4.19E+07 O.OOE+OO 3.47E+06 1.79E+06 3.82E+08 5.19E+06 O.OOE+OO 1.31E+09 7.45E+08 4.33E+11 2.15E+09 O.OOE+OO 1.27E+OO 5.84E-01 5.89E+01 1.94E+OO O.OOE+OO 2.13E+07 8.05E+06 3.95E+09 3.55E+07 O.OOE+OO 1.47E-11 6.79E-12 3.39E-10 2.26E-11 O.OOE+OO 9.78E+04 4.62E+04 8.66E+06 1.50E+05 O.OOE+OO 3.72E+10 7.84E+09 O.OOE+OO 1.15E+10 4.13E+09 2.77E+09 1.80E+09 O.OOE+OO 1.48E+09 2.20E+08 3.09E+10 4.55E+09 O.OOE+OO 1.01E+10 3.62E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.08E-10 5.84E-09 O.OOE+OO 9.39E-11 6.33E-11 1.03E+05 6.84E+06 O.OOE+OO 3.34E+04 6.12E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.80E+OO 2.29E+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.63E-11 8.22E-12 O.OOE+OO O.OOE+OO O.OOE+OO 1.09E+04 1.62E+03 O.OOE+OO 4.78E+03 O.OOE+OO 1.01 E+05 1.47E+01 O.OOE+OO 4.26E+01 O.OOE+OO 5.09E+05 8.66E+04 O.OOE+OO 2.82E+05 O.OOE+OO 2.16E+02 3.57E+01 O.OOE+OO 1.17E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.63E+02 2.81E+01 O.OOE+OO 1.99E+02 O.OOE+OO 1.71E+04 7.67E+03 O.OOE+OO O.OOE+OO O.OOE+OO 1.24E+OO 8.69E-01 O.OOE+OO 3.58E+OO O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GI-LLI 7.12E+07 1.68E+08 1.19E+05 3.31 E+08 7.99E-08 2.24E+07 O.OOE+OO 4.55E+07 1.62E+06 1.17E+08 1.49E+OO 8.57E+06 9.78E-12 7.45E+04 2.00E+08 9.75E+07 1.93E+08 O.OOE+OO 1.16E-05 5.94E+07 O.OOE+OO O.OOE+OO 1.90E+05 5.20E-06 1.36E+07 1.49E+06 1.33E+08 7.75E+05 O.OOE+OO 5.75E+05 2.40E+06 9.15E+04

N l"d UCI e H-3 C-14 Na-24 Cr-51 Mn-54 Mn-56 Fe-55 Fe-59 Co-58 Co-60 Ni-63 Ni-65 Cu-64 Zn-65 Zn-69 Br-83 Br-84 Br-85 Rb-86 Rb-88 Rb-89 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91M Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99M Tc-101 Ru-103 Ru-105 Ru-106 Ag-110M Table 4-19 Infant Grass-Cow-Milk Dose Factors CY-BY-170-301 Revision 15 Page 145 of 188 B

L" TB d Th "d

K"d one 1ver 0 y 1yro1 1 ney L ung O.OOE+OO 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 1.56E+07 1.56E+07 1.56E+07 1.56E+07 1.56E+07 1.56E+07 O.OOE+OO O.OOE+OO 1.61E+05 1.05E+05 2.30E+04 2.05E+05 O.OOE+OO 3.90E+07 8.84E+06 O.OOE+OO 8.64E+06 O.OOE+OO O.OOE+OO 3.13E-02 5.39E-03 O.OOE+OO 2.69E-02 O.OOE+OO 1.35E+08 8.73E+07 2.33E+07 O.OOE+OO O.OOE+OO 4.27E+07 2.24E+08 3.92E+08 1.54E+08 O.OOE+OO O.OOE+OO 1.16E+08 O.OOE+OO 2.43E+07 6.05E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.82E+07 2.08E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.49E+10 2.16E+09 1.21E+09 O.OOE+OO O.OOE+OO O.OOE+OO 3.51E+OO 3.97E-01 1.81 E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.84E+05 8.51 E+04 O.OOE+OO 3.11E+05 O.OOE+OO 5.55E+09 1.90E+10 8.78E+09 O.OOE+OO 9.23E+09 O.OOE+OO 1.94E-11 3.49E-11 2.60E-12 O.OOE+OO 1.45E-11 O.OOE+OO O.OOE+OO O.OOE+OO 9.27E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.23E+10 1.10E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.26E+10 O.OOE+OO 3.61E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.86E+11 O.OOE+OO 3.77E+09 O.OOE+OO O.OOE+OO O.OOE+OO 2.70E+05 O.OOE+OO 9.76E+03 O.OOE+OO O.OOE+OO O.OOE+OO 4.60E+OO O.OOE+OO 1.71 E-01 O.OOE+OO O.OOE+OO O.OOE+OO 6.82E+02 O.OOE+OO 1.83E+01 O.OOE+OO O.OOE+OO O.OOE+OO 6.09E-19 O.OOE+OO 2.07E-20 O.OOE+OO O.OOE+OO O.OOE+OO 7.33E+04 O.OOE+OO 1.95E+03 O.OOE+OO O.OOE+OO O.OOE+OO 5.37E-04 O.OOE+OO 1.51 E-05 O.OOE+OO O.OOE+OO O.OOE+OO 2.14E+OO O.OOE+OO 5.83E-02 O.OOE+OO O.OOE+OO O.OOE+OO 6.81 E+03 1.66E+03 1.18E+03 O.OOE+OO 1.79E+03 O.OOE+OO 4.05E+OO 6.96E-01 3.18E-01 O.OOE+OO 7.01 E-01 O.OOE+OO 5.94E+05 2.45E+05 1.41 E+05 O.OOE+OO 1.75E+05 O.OOE+OO O.OOE+OO 2.08E+08 4.05E+07 O.OOE+OO 3.10E+08 O.OOE+OO 2.74E+01 5.65E+01 7.27E+02 O.OOE+OO 6.0BE+02 2.95E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.67E+03 O.OOE+OO 2.90E+03 O.OOE+OO 1.80E+04 O.OOE+OO 8.00E-03 O.OOE+OO 2.69E-03 O.OOE+OO 5.88E-02 O.OOE+OO 1.90E+05 O.OOE+OO 2.38E+04 O.OOE+OO 2.25E+05 O.OOE+OO 3.86E+08 2.82E+08 1.86E+08 O.OOE+OO 4.03E+08 O.OOE+OO GILLI 1.36E+03 6.89E+05 1.56E+07 4.70E+06 1.43E+07 2.84E+OO 1.11 E+07 1.87E+08 6.04E+07 2.10E+08 1.07E+08 3.02E+01 3.77E+06 1.61 E+10 2.85E-09 O.OOE+OO O.OOE+OO O.OOE+OO 5.70E+08 O.OOE+OO O.OOE+OO 2.59E+08 1.52E+09 3.19E+05 4.96E+01 9.42E+05 2.03E-15 5.25E+06 1.02E+01 1.69E+04 8.26E+05 4.44E+04 2.07E+08 6.84E+07 1.64E+04 O.OOE+OO 1.05E+05 3.18E+OO 1.44E+06 1.46E+10

Nuclide Bone Te-125M 1.51 E+08 Te-127M 4.21E+08 Te-127 6.45E+03 Te-129M 5.57E+08 Te-129 2.72E-09 Te-131M 3.37E+06 Te-131 O.OOE+OO Te-132 2.10E+07 1-130 3.53E+06 1-131 2.72E+09 1-132 1.43E+OO 1-133 3.63E+07 1-134 1.65E-11 1-135 1.13E+05 Cs-134 3.65E+10 Cs-136 1.97E+09 Cs-137 5.15E+10 Cs-138 O.OOE+OO Ba-139 4.29E-07 Ba-140 2.41E+08 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 4.06E+01 La-142 1.73E-10 Ce-141 4.34E+04 Ce-143 3.96E+02 Ce-144 2.33E+06 Pr-143 1.49E+03 Pr-144 O.OOE+OO Nd-147 8.88E+02 W-187 6.08E+04 Np-239 3.64E+01 Notes:

Table 4-19 (Continued)

CY-BY-170-301 Revision 15 Page 146 of 188 Infant Grass-Cow-Milk Dose Factors Liver T Body Thyroid Kidney Lung 5.04E+07 2.04E+07 5.08E+07 O.OOE+OO O.OOE+OO 1.40E+08 5.10E+07 1.22E+08 1.04E+09 O.OOE+OO 2.16E+03 1.39E+03 5.25E+03 1.57E+04 O.OOE+OO 1.91E+08 8.58E+07 2.14E+08 1.39E+09 O.OOE+OO 9.38E-10 6.35E-10 2.28E-09 6.77E-09 O.OOE+OO 1.36E+06 1.12E+06 2.75E+06 9.35E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+07 9.71E+06 1.54E+07 6.51E+07 O.OOE+OO 7.77E+06 3.12E+06 8.71 E+08 8.53E+06 O.OOE+OO 3.20E+09 1.41 E+09 1.05E+12 3.74E+09 O.OOE+OO 2.91E+OO 1.04E+OO 1.36E+02 3.25E+OO O.OOE+OO 5.29E+07 1.55E+07 9.62E+09 6.22E+07 O.OOE+OO 3.37E-11 1.20E-11 7.87E-10 3.77E-11 O.OOE+OO 2.25E+05 8.19E+04 2.01E+07 2.50E+05 O.OOE+OO 6.80E+10 6.87E+09 O.OOE+OO 1.75E+10 7.18E+09 5.80E+09 2.16E+09 O.OOE+OO 2.31E+09 4.72E+08 6.02E+10 4.27E+09 O.OOE+OO 1.62E+10 6.55E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.84E-10 1.24E-08 O.OOE+OO 1.71E-10 1.72E-10 2.41E+05 1.24E+07 O.OOE+OO 5.72E+04 1.48E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.60E+01 4.12E+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.35E-11 1.52E-11 O.OOE+OO O.OOE+OO O.OOE+OO 2.64E+04 3.11E+03 O.OOE+OO 8.15E+03 O.OOE+OO 2.63E+05 3.00E+01 O.OOE+OO 7.65E+01 O.OOE+OO 9.52E+05 1.30E+05 O.OOE+OO 3.85E+05 O.OOE+OO 5.56E+02 7.37E+01 O.OOE+OO 2.07E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.12E+02 5.59E+01 O.OOE+OO 3.51 E+02 O.OOE+OO 4.23E+04 1.46E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.26E+OO 1.84E+OO O.OOE+OO 6.50E+OO O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

GI-LLI 7.19E+07 1.70E+08 1.35E+05 3.33E+08 2.17E-07 2.29E+07 O.OOE+OO 3.85E+07 1.67E+06 1.14E+08 2.36E+OO 8.95E+06 3.49E-11 8.13E+04 1.85E+08 8.80E+07 1.88E+08 O.OOE+OO 2.72E-05 5.92E+07 O.OOE+OO O.OOE+OO 1.88E+05 1.08E-05 1.37E+07 1.53E+06 1.33E+08 7.84E+05 O.OOE+OO 5.78E+05 2.48E+06 9.42E+04

N l"d UCI e B one H-3 O.OOE+OO C-14 3.63E+05 Na-24 2.95E+05 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 3.26E+05 Fe-59 3.86E+05 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 8.07E+08 Ni-65 4.44E-02 Cu-64 O.OOE+OO Zn-65 1.65E+08 Zn-69 2.41E-13 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 3.05E+09 Sr-90 1.13E+11 Sr-91 6.03E+04 Sr-92 1.02E+OO Y-90 8.52E+OO Y-91M O.OOE+OO Y-91 1.03E+03 Y-92 6.68E-06 Y-93 2.66E-02 Zr-95 1.13E+02 Zr-97 5.19E-02 Nb-95 9.92E+03 Mo-99 O.OOE+OO Tc-99M 3.97E-01 Tc-101 O.OOE+OO Ru-103 1.22E+02 Ru-105 1.02E-04 Ru-106 2.45E+03 Ag-110M 6.99E+06 Table 4-20 CY-BY-170-301 Revision 15 Page 147 of 188 Adult Grass-Goat-Milk Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung 8.88E+02 8.88E+02 8.88E+02 8.88E+02 8.88E+02 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 O.OOE+OO 3.43E+03 2.05E+03 7.55E+02 4.55E+03 1.01 E+06 1.93E+05 O.OOE+OO 3.00E+05 O.OOE+OO 4.95E-04 8.79E-05 O.OOE+OO 6.29E-04 O.OOE+OO 2.26E+05 5.26E+04 O.OOE+OO O.OOE+OO 1.26E+05 9.07E+05 3.48E+05 O.OOE+OO O.OOE+OO 2.53E+05 5.66E+05 1.27E+06 O.OOE+OO O.OOE+OO O.OOE+OO 1.97E+06 4.34E+06 O.OOE+OO O.OOE+OO O.OOE+OO 5.60E+07 2.71 E+07 O.OOE+OO O.OOE+OO O.OOE+OO 5.77E-03 2.63E-03 O.OOE+OO O.OOE+OO O.OOE+OO 2.63E+03 1.23E+03 O.OOE+OO 6.63E+03 O.OOE+OO 5.24E+08 2.37E+08 O.OOE+OO 3.50E+08 O.OOE+OO 4.61 E-13 3.21 E-14 O.OOE+OO 3.00E-13 O.OOE+OO O.OOE+OO 1.16E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.12E+08 1.45E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.74E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.27E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.44E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.39E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.28E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.76E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.95E-07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.34E-04 O.OOE+OO O.OOE+OO O.OOE+OO 3.63E+01 2.46E+01 O.OOE+OO 5.70E+01 O.OOE+OO 1.05E-02 4.79E-03 O.OOE+OO 1.58E-02 O.OOE+OO 5.52E+03 2.97E+03 O.OOE+OO 5.45E+03 O.OOE+OO 2.97E+06 5.65E+05 O.OOE+OO 6.72E+06 O.OOE+OO 1.12E+OO 1.43E+01 O.OOE+OO 1.70E+01 5.50E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.26E+01 O.OOE+OO 4.66E+02 O.OOE+OO O.OOE+OO 4.03E-05 O.OOE+OO 1.32E-03 O.OOE+OO O.OOE+OO 3.10E+02 O.OOE+OO 4.73E+03 O.OOE+OO 6.46E+06 3.84E+06 O.OOE+OO 1.27E+07 O.OOE+OO GILLI 8.88E+02 7.26E+04 2.95E+05 8.62E+05 3.09E+06 1.58E-02 1.29E+05 3.02E+06 1.15E+07 3.70E+07 1.17E+07 1.46E-01 2.24E+05 3.30E+08 6.93E-14 1.67E-02 O.OOE+OO O.OOE+OO 6.15E+07 O.OOE+OO O.OOE+OO 4.88E+08 2.84E+09 2.87E+05 2.01E+01 9.03E+04 2.26E-20 5.67E+05 1.17E-01 8.43E+02 1.15E+05 3.24E+03 3.35E+07 6.88E+06 6.64E+02 O.OOE+OO 1.43E+04 6.25E-02 1.58E+05 2.64E+09

d Nucli e B one Te-125M 1.96E+06 Te-127M 5.49E+06 Te-127 8.00E+01 Te-129M 7.22E+06 Te-129 3.39E-11 Te-131M 4.33E+04 Te-131 O.OOE+OO Te-132 2.87E+05 1-130 5.01 E+05 1-131 3.55E+08 1-132 1.98E-01 1-133 4.65E+06 1-134 2.27E-12 1-135 1.55E+04 Cs-134 1.70E+10 Cs-136 7.88E+08 Cs-137 2.21 E+10 Cs-138 O.OOE+OO Ba-139 5.32E-09 Ba-140 3.23E+06 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 5.43E-01 La-142 2.27E-12 Ce-141 5.81E+02 Ce-143 4.98E+OO Ce-144 4.29E+04 Pr-143 1.90E+01 Pr-144 O.OOE+OO Nd-147 1.14E+01 W-187 7.82E+02 Np-239 4.40E-01 Notes:

Table 4-20 (Continued)

CY-BY-170-301 Revision 15 Page 148 of 188 Adult Grass-Goat-Milk Dose Factors L" 1ver TB d O IV Th "d

K"d 1vro1 1 ney L ung 7.09E+05 2.62E+05 5.88E+05 7.95E+06 O.OOE+OO 1.96E+06 6.69E+05 1.40E+06 2.23E+07 O.OOE+OO 2.87E+01 1.73E+01 5.92E+01 3.26E+02 O.OOE+OO 2.69E+06 1.14E+06 2.48E+06 3.01 E+07 O.OOE+OO 1.27E-11 8.26E-12 2.60E-11 1.43E-10 O.OOE+OO 2.12E+04 1.76E+04 3.35E+04 2.14E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.86E+05 1.74E+05 2.05E+05 1.79E+06 O.OOE+OO 1.48E+06 5.84E+05 1.25E+08 2.31E+06 O.OOE+OO 5.08E+08 2.91E+08 1.67E+11 8.71 E+08 O.OOE+OO 5.29E-01 1.85E-01 1.85E+01 8.42E-01 O.OOE+OO 8.09E+06 2.47E+06 1.19E+09 1.41 E+07 O.OOE+OO 6.15E-12 2.20E-12 1.07E-10 9.79E-12 O.OOE+OO 4.06E+04 1.50E+04 2.68E+06 6.51E+04 O.OOE+OO 4.04E+10 3.30E+10 O.OOE+OO 1.31E+10 4.34E+09 3.11E+09 2.24E+09 O.OOE+OO 1.73E+09 2.37E+08 3.03E+10 1.98E+10 O.OOE+OO 1.03E+10 3.42E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.79E-12 1.56E-10 O.OOE+OO 3.54E-12 2.15E-12 4.05E+03 2.11E+05 O.OOE+OO 1.38E+03 2.32E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.74E-01 7.23E-02 O.OOE+OO O.OOE+OO O.OOE+OO 1.03E-12 2.57E-13 O.OOE+OO O.OOE+OO O.OOE+OO 3.93E+02 4.46E+01 O.OOE+OO 1.83E+02 O.OOE+OO 3.68E+03 4.07E-01 O.OOE+OO 1.62E+OO O.OOE+OO 1.79E+04 2.30E+03 O.OOE+OO 1.06E+04 O.OOE+OO 7.60E+OO 9.40E-01 O.OOE+OO 4.39E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.32E+01 7.87E-01 O.OOE+OO 7.69E+OO O.OOE+OO 6.53E+02 2.28E+02 O.OOE+OO O.OOE+OO O.OOE+OO 4.33E-02 2.39E-02 O.OOE+OO 1.35E-01 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

GILLI 7.81 E+06 1.84E+07 6.31 E+03 3.64E+07 2.56E-11 2.10E+06 O.OOE+OO 8.78E+06 1.27E+06 1.34E+08 9.93E-02 7.27E+06 5.36E-15 4.58E+04 7.06E+08 3.53E+08 5.86E+08 O.OOE+OO 9.44E-09 6.64E+06 O.OOE+OO O.OOE+OO 2.01E+04 7.53E-09 1.50E+06 1.38E+05 1.45E+07 8.31 E+04 O.OOE+OO 6.31E+04 2.14E+05 8.88E+03

N I'd UCI e B one H-3 O.OOE+OO C-14 6.70E+05 Na-24 5.15E+05 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 5.79E+05 Fe-59 6.74E+05 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.42E+09 Ni-65 8.13E-02 Cu-64 O.OOE+OO Zn-65 2.53E+08 Zn-69 4.44E-13 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 5.61 E+09 Sr-90 1.71E+11 Sr-91 1.11E+05 Sr-92 1.86E+OO Y-90 1.56E+01 Y-91M 1.41 E-20 Y-91 1.90E+03 Y-92 1.23E-05 Y-93 4.90E-02 Zr-95 1.98E+02 Zr-97 9.44E-02 Nb-95 1.69E+04 Mo-99 O.OOE+OO Tc-99M 6.89E-01 Tc-101 O.OOE+OO Ru-103 2.17E+02 Ru-105 1.86E-04 Ru-106 4.50E+03 Ag-110M 1.16E+07 Table 4-21 CY-BY-170-301 Revision 15 Page 149 of 188 Teen Grass-Goat-Milk Dose Factors L" 1ver TB d O IY Th "d

K"d 1yro1 1 ney L ung 1.16E+03 1.16E+03 1.16E+03 1.16E+03 1.16E+03 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 O.OOE+OO 5.99E+03 3.33E+03 1.31 E+03 8.55E+03 1.68E+06 3.34E+05 O.OOE+OO 5.02E+05 O.OOE+OO 8.78E-04 1.56E-04 O.OOE+OO 1.11 E-03 O.OOE+OO 4.11E+05 9.57E+04 O.OOE+OO O.OOE+OO 2.60E+05 1.57E+06 6.07E+05 O.OOE+OO O.OOE+OO 4.96E+05 9.53E+05 2.20E+06 O.OOE+OO O.OOE+OO O.OOE+OO 3.34E+06 7.52E+06 O.OOE+OO O.OOE+OO O.OOE+OO 1.00E+08 4.81 E+07 O.OOE+OO O.OOE+OO O.OOE+OO 1.04E-02 4.73E-03 O.OOE+OO O.OOE+OO O.OOE+OO 4.69E+03 2.20E+03 O.OOE+OO 1.19E+04 O.OOE+OO 8.78E+08 4.09E+08 O.OOE+OO 5.62E+08 O.OOE+OO 8.46E-13 5.92E-14 O.OOE+OO 5.53E-13 O.OOE+OO O.OOE+OO 2.13E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.68E+08 2.67E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.61 E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.41E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.41E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.92E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.21 E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.08E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.57E-07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.34E-03 O.OOE+OO O.OOE+OO O.OOE+OO 6.25E+01 4.30E+01 O.OOE+OO 9.18E+01 O.OOE+OO 1.87E-02 8.61E-03 O.OOE+OO 2.83E-02 O.OOE+OO 9.38E+03 5.16E+03 O.OOE+OO 9.09E+03 O.OOE+OO 5.36E+06 1.02E+06 O.OOE+OO 1.23E+07 O.OOE+OO 1.92E+OO 2.49E+01 O.OOE+OO 2.86E+01 1.07E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.29E+01 O.OOE+OO 7.66E+02 O.OOE+OO O.OOE+OO 7.24E-05 O.OOE+OO 2.35E-03 O.OOE+OO O.OOE+OO 5.67E+02 O.OOE+OO 8.68E+03 O.OOE+OO 1.09E+07 6.65E+06 O.OOE+OO 2.09E+07 O.OOE+OO GILLI 1.16E+03 1.34E+05 5.15E+05 1.01 E+06 3.45E+06 5.78E-02 1.78E+05 3.72E+06 1.31 E+07 4.35E+07 1.59E+07 5.63E-01 3.64E+05 3.72E+08 1.56E-12 O.OOE+OO O.OOE+OO O.OOE+OO 8.41E+07 O.OOE+OO O.OOE+OO 6.69E+08 3.90E+09 5.02E+05 4.74E+01 1.29E+05 6.66E-19 7.77E+05 3.39E-01 1.50E+03 1.44E+05 5.06E+03 4.01E+07 9.59E+06 1.26E+03 O.OOE+OO 1.81E+04 1.51 E-01 2.16E+05 3.07E+09

Nuclide Bone Te-125M 3.61E+06 Te-127M 1.01E+07 Te-127 1.48E+02 Te-129M 1.32E+07 Te-129 6.24E-11 Te-131M 7.88E+04 Te-131 O.OOE+OO Te-132 5.13E+05 1-130 8.82E+05 1-131 6.45E+08 1-132 3.50E-01 1-133 8.50E+06 1-134 4.03E-12 1-135 2.75E+04 Cs-134 2.94E+10 Cs-136 1.34E+09 Cs-137 4.02E+10 Cs-138 O.OOE+OO Ba-139 9.84E-09 Ba-140 5.82E+06 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 9.75E-01 La-142 4.09E-12 Ce-141 1.07E+03 Ce-143 9.15E+OO Ce-144 7.90E+04 Pr-143 3.48E+01 Pr-144 O.OOE+OO Nd-147 2.19E+01 W-187 1.43E+03 Np-239 8.40E-01 Notes:

Table 4-21 (Continued)

CY-BY-170-301 Revision 15 Page 150 of 188 Teen Grass-Goat-Milk Dose Factors Liver T Body Thyroid Kidney Lung 1.30E+06 4.82E+05 1.01E+06 O.OOE+OO O.OOE+OO 3.59E+06 1.20E+06 2.41E+06 4.10E+07 O.OOE+OO 5.25E+01 3.19E+01 1.02E+02 6.00E+02 O.OOE+OO 4.90E+06 2.09E+06 4.26E+06 5.53E+07 O.OOE+OO 2.33E-11 1.52E-11 4.46E-11 2.62E-10 O.OOE+OO 3.78E+04 3.15E+04 5.68E+04 3.94E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.25E+05 3.06E+05 3.42E+05 3.12E+06 O.OOE+OO 2.55E+06 1.02E+06 2.08E+08 3.93E+06 O.OOE+OO 9.02E+08 4.85E+08 2.63E+11 1.55E+09 O.OOE+OO 9.17E-01 3.29E-01 3.09E+01 1.44E+OO O.OOE+OO 1.44E+07 4.40E+06 2.01E+09 2.53E+07 O.OOE+OO 1.07E-11 3.83E-12 1.78E-10 1.68E-11 O.OOE+OO 7.09E+04 2.63E+04 4.56E+06 1.12E+05 O.OOE+OO 6.93E+10 3.22E+10 O.OOE+OO 2.20E+10 8.41 E+09 5.28E+09 3.54E+09 O.OOE+OO 2.87E+09 4.53E+08 5.34E+10 1.86E+10 O.OOE+OO 1.82E+10 7.06E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.92E-12 2.87E-10 O.OOE+OO 6.53E-12 4.77E-12 7.14E+03 3.75E+05 O.OOE+OO 2.42E+03 4.80E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.79E-01 1.27E-01 O.OOE+OO O.OOE+OO O.OOE+OO 1.82E-12 4.53E-13 O.OOE+OO O.OOE+OO O.OOE+OO 7.12E+02 8.17E+01 O.OOE+OO 3.35E+02 O.OOE+OO 6.66E+03 7.44E-01 O.OOE+OO 2.99E+OO O.OOE+OO 3.27E+04 4.24E+03 O.OOE+OO 1.95E+04 O.OOE+OO 1.39E+01 1.73E+OO O.OOE+OO 8.08E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.38E+01 1.43E+OO O.OOE+OO 1.40E+01 O.OOE+OO 1.17E+03 4.08E+02 O.OOE+OO O.OOE+OO O.OOE+OO 7.92E-02 4.40E-02 O.OOE+OO 2.49E-01 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GI-LLI 1.06E+07 2.52E+07 1.14E+04 4.96E+07 3.41E-10 3.03E+06 O.OOE+OO 1.03E+07 1.96E+06 1.78E+08 3.99E-01 1.09E+07 1.41 E-13 7.85E+04 8.62E+08 4.25E+08 7.60E+08 O.OOE+OO 8.78E-08 8.98E+06 O.OOE+OO O.OOE+OO 2.75E+04 5.53E-08 2.04E+06 2.00E+05 1.99E+07 1.15E+05 O.OOE+OO 8.59E+04 3.15E+05 1.27E+04

N l"d UCI e B one H-3 O.OOE+OO C-14 1.65E+06 Na-24 1.07E+06 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 1.45E+06 Fe-59 1.56E+06 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 3.56E+09 Ni-65 1.99E-01 Cu-64 O.OOE+OO Zn-65 4.96E+08 Zn-69 1.09E-12 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 1.39E+10 Sr-90 3.53E+11 Sr-91 2.72E+05 Sr-92 4.54E+OO Y-90 3.87E+01 Y-91M 3.45E-20 Y-91 4.68E+03 Y-92 3.03E-05 Y-93 1.20E-01 Zr-95 4.60E+02 Zr-97 2.30E-01 Nb-95 3.82E+04 Mo-99 O.OOE+OO Tc-99M 1.58E+OO Tc-101 O.OOE+OO Ru-103 5.14E+02 Ru-105 4.55E-04 Ru-106 1.11E+04 Ag-110M 2.51E+07 Table 4-22 CY-BY-170-301 Revision 15 Page 151 of 188 Child Grass-Goat-Milk Dose Factors L"

TB d Th "d

K"d 1ver 0 ly 1yro1 1 ney L ung 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 O.OOE+OO 1.22E+04 6.78E+03 1.85E+03 1.24E+04 2.52E+06 6.70E+05 O.OOE+OO 7.06E+05 O.OOE+OO 1.53E-03 3.46E-04 O.OOE+OO 1.85E-03 O.OOE+OO 7.71 E+OS 2.39E+05 O.OOE+OO O.OOE+OO 4.36E+05 2.53E+06 1.26E+06 O.OOE+OO O.OOE+OO 7.33E+05 1.46E+06 4.46E+06 O.OOE+OO O.OOE+OO O.OOE+OO 5.18E+06 1.53E+07 O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+08 1.21E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.87E-02 1.09E-02 O.OOE+OO O.OOE+OO O.OOE+OO 8.24E+03 4.98E+03 O.OOE+OO 1.99E+04 O.OOE+OO 1.32E+09 8.22E+08 O.OOE+OO 8.33E+08 O.OOE+OO 1.58E-12 1.46E-13 O.OOE+OO 9.57E-13 O.OOE+OO O.OOE+OO 5.24E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.05E+09 6.48E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.97E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.11E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.03E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.82E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.25E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.67E-07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.31E-03 O.OOE+OO O.OOE+OO O.OOE+OO 1.01E+02 9.00E+01 O.OOE+OO 1.45E+02 O.OOE+OO 3.32E-02 1.96E-02 O.OOE+OO 4.77E-02 O.OOE+OO 1.49E+04 1.06E+04 O.OOE+OO 1.40E+04 O.OOE+OO 9.75E+06 2.41E+06 O.OOE+OO 2.08E+07 O.OOE+OO 3.10E+OO 5.14E+01 O.OOE+OO 4.50E+01 1.57E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.97E+02 O.OOE+OO 1.29E+03 O.OOE+OO O.OOE+OO 1.65E-04 O.OOE+OO 4.00E-03 O.OOE+OO O.OOE+OO 1.38E+03 O.OOE+OO 1.50E+04 O.OOE+OO 1.69E+07 1.35E+07 O.OOE+OO 3.15E+07 O.OOE+OO GILLI 1.83E+03 3.29E+05 1.07E+06 6.47E+05 2.11E+06 2.22E-01 1.43E+05 2.63E+06 8.49E+06 2.87E+07 1.28E+07 2.29E+OO 3.87E+05 2.32E+08 9.95E-11 O.OOE+OO O.OOE+OO O.OOE+OO 6.78E+07 O.OOE+OO O.OOE+OO 5.38E+08 3.16E+09 6.00E+OS 8.60E+01 1.10E+05 6.75E-17 6.24E+05 8.75E-01 1.80E+03 1.05E+05 5.03E+03 2.75E+07 8.06E+06 1.76E+03 O.OOE+OO 1.33E+04 2.97E-01 1.72E+05 2.01 E+09

Nuclide Bone Te-125M 8.86E+06 Te-127M 2.50E+07 Te-127 3.64E+02 Te-129M 3.26E+07 Te-129 1.54E-10 Te-131M 1.92E+05 Te-131 O.OOE+OO Te-132 1.22E+06 1-130 2.06E+06 1-131 1.56E+09 1-132 8.29E-01 1-133 2.06E+07 1-134 9.53E-12 1-135 6.52E+04 Cs-134 6.79E+10 Cs-136 3.03E+09 Cs-137 9.67E+10 Cs-138 O.OOE+OO Ba-139 2.42E-08 Ba-140 1.41E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 2.33E+OO La-142 9.88E-12 Ce-141 2.62E+03 Ce-143 2.25E+01 Ce-144 1.95E+05 Pr-143 8.62E+01 Pr-144 O.OOE+OO Nd-147 5.37E+01 W-187 3.47E+03 Np-239 2.07E+OO Notes:

Table 4-22 (Continued)

CY -BY -170-301 Revision 15 Page 152 of 188 Child Grass-Goat-Milk Dose Factors Liver T Body Thyroid Kidney Lung 2.40E+06 1.18E+06 2.49E+06 O.OOE+OO O.OOE+OO 6.72E+06 2.96E+06 5.97E+06 7.12E+07 O.OOE+OO 9.83E+01 7.82E+01 2.52E+02 1.04E+03 O.OOE+OO 9.09E+06 5.05E+06 1.05E+07 9.56E+07 O.OOE+OO 4.30E-11 3.66E-11 1.10E-10 4.51E-10 O.OOE+OO 6.63E+04 7.06E+04 1.36E+05 6.42E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.42E+05 6.55E+05 7.89E+05 5.03E+06 O.OOE+OO 4.17E+06 2.15E+06 4.59E+08 6.23E+06 O.OOE+OO 1.57E+09 8.94E+08 5.20E+11 2.58E+09 O.OOE+OO 1.52E+OO 7.00E-01 7.07E+01 2.33E+OO O.OOE+OO 2.55E+07 9.66E+06 4.74E+09 4.25E+07 O.OOE+OO 1.77E-11 8.14E-12 4.07E-10 2.71E-11 O.OOE+OO 1.17E+05 5.55E+04 1.04E+07 1.80E+05 O.OOE+OO 1.11E+11 2.35E+10 O.OOE+OO 3.45E+10 1.24E+10 8.32E+09 5.39E+09 O.OOE+OO 4.43E+09 6.61E+08 9.26E+10 1.37E+10 O.OOE+OO 3.02E+10 1.09E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.29E-11 7.01E-10 O.OOE+OO 1.13E-11 7.59E-12 1.23E+04 8.21E+05 O.OOE+OO 4.01E+03 7.34E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.16E-01 2.75E-01 O.OOE+OO O.OOE+OO O.OOE+OO 3.15E-12 9.87E-13 O.OOE+OO O.OOE+OO O.OOE+OO 1.31E+03 1.94E+02 O.OOE+OO 5.74E+02 O.OOE+OO 1.22E+04 1.76E+OO O.OOE+OO 5.11E+OO O.OOE+OO 6.11E+04 1.04E+04 O.OOE+OO 3.38E+04 O.OOE+OO 2.59E+01 4.28E+OO O.OOE+OO 1.40E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.35E+01 3.37E+OO O.OOE+OO 2.39E+01 O.OOE+OO 2.05E+03 9.21 E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.48E-01 1.04E-01 O.OOE+OO 4.29E-01 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GI-LLI 8.55E+06 2.02E+07 1.42E+04 3.97E+07 9.59E-09 2.69E+06 O.OOE+OO 5.46E+06 1.95E+06 1.40E+08 1.79E+OO 1.03E+07 1.17E-11 8.94E+04 6.01E+08 2.92E+08 5.80E+08 O.OOE+OO 1.40E-06 7.12E+06 O.OOE+OO O.OOE+OO 2.27E+04 6.24E-07 1.63E+06 1.78E+05 1.59E+07 9.30E+04 O.OOE+OO 6.89E+04 2.88E+05 1.10E+04

N l"d UCI e 8 one H-3 O.OOE+OO C-14 3.23E+06 Na-24 1.87E+06 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 1.76E+06 Fe-59 2.92E+06 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 4.19E+09 Ni-65 4.21 E-01 Cu-64 O.OOE+OO Zn-65 6.66E+08 Zn-69 2.33E-12 Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 2.64E+10 Sr-90 3.91E+11 Sr-91 5.66E+05 Sr-92 9.65E+OO Y-90 8.19E+01 Y-91M 7.31E-20 Y-91 8.79E+03 Y-92 6.44E-05 Y-93 2.57E-01 Zr-95 8.17E+02 Zr-97 4.87E-01 Nb-95 7.13E+04 Mo-99 O.OOE+OO Tc-99M 3.29E+OO Tc-101 O.OOE+OO Ru-103 1.04E+03 Ru-105 9.60E-04 Ru-106 2.28E+04 Ag-110M 4.63E+07 Table 4-23 CY -BY -170-301 Revision 15 Page 153 of 188 Infant Grass-Goat-Milk Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung 2.78E+03 2.78E+03 2.78E+03 2.78E+03 2.78E+03 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 O.OOE+OO 1.93E+04 1.26E+04 2.76E+03 2.46E+04 4.68E+06 1.06E+06 O.OOE+OO 1.04E+06 O.OOE+OO 3.75E-03 6.47E-04 O.OOE+OO 3.22E-03 O.OOE+OO 1.13E+06 3.03E+05 O.OOE+OO O.OOE+OO 5.55E+05 5.09E+06 2.01E+06 O.OOE+OO O.OOE+OO 1.51E+06 2.91E+06 7.26E+06 O.OOE+OO O.OOE+OO O.OOE+OO 1.06E+07 2.50E+07 O.OOE+OO O.OOE+OO O.OOE+OO 2.59E+08 1.45E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.77E-02 2.17E-02 O.OOE+OO O.OOE+OO O.OOE+OO 2.05E+04 9.48E+03 O.OOE+OO 3.46E+04 O.OOE+OO 2.28E+09 1.05E+09 O.OOE+OO 1.11E+09 O.OOE+OO 4.19E-12 3.12E-13 O.OOE+OO 1.74E-12 O.OOE+OO O.OOE+OO 1.11 E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.67E+09 1.32E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.58E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.92E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.05E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.59E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.20E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.34E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.81 E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.99E-03 O.OOE+OO O.OOE+OO O.OOE+OO 1.99E+02 1.41E+02 O.OOE+OO 2.15E+02 O.OOE+OO 8.35E-02 3.81 E-02 O.OOE+OO 8.42E-02 O.OOE+OO 2.94E+04 1.70E+04 O.OOE+OO 2.10E+04 O.OOE+OO 2.49E+07 4.86E+06 O.OOE+OO 3.72E+07 O.OOE+OO 6.78E+OO 8.73E+01 O.OOE+OO 7.29E+01 3.54E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.48E+02 O.OOE+OO 2.16E+03 O.OOE+OO O.OOE+OO 3.23E-04 O.OOE+OO 7.06E-03 O.OOE+OO O.OOE+OO 2.85E+03 O.OOE+OO 2.70E+04 O.OOE+OO 3.38E+07 2.24E+07 O.OOE+OO 4.84E+07 O.OOE+OO GILLI 2.78E+03 6.89E+05 1.87E+06 5.64E+05 1.72E+06 3.41 E-01 1.44E+05 2.43E+06 7.25E+06 2.52E+07 1.29E+07 3.63E+OO 4.20E+05 1.93E+09 3.42E-10 O.OOE+OO O.OOE+OO O.OOE+OO 6.84E+07 O.OOE+OO O.OOE+OO 5.43E+08 3.19E+09 6.70E+05 1.04E+02 1.13E+05 2.44E-16 6.30E+05 1.23E+OO 2.03E+03 9.91E+04 5.33E+03 2.48E+07 8.21 E+06 1.97E+03 O.OOE+OO 1.27E+04 3.82E-01 1.73E+05 1.75E+09

Nuclide B one Te-125M 1.81E+07 Te-127M 5.05E+07 Te-127 7.74E+02 Te-129M 6.68E+07 Te-129 3.26E-10 Te-131 M 4.05E+05 Te-131 O.OOE+OO Te-132 2.52E+06 1-130 4.24E+06 1-131 3.26E+09 1-132 1.72E+OO 1-133 4.36E+07 1-134 1.98E-11 1-135 1.36E+05 Cs-134 1.09E+11 Cs-136 5.91E+09 Cs-137 1.54E+11 Cs-138 O.OOE+OO Ba-139 5.14E-08 Ba-140 2.89E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 4.88E+OO La-142 2.0SE-11 Ce-141 5.20E+03 Ce-143 4.75E+01 Ce-144 2.79E+05 Pr-143 1.78E+02 Pr-144 O.OOE+OO Nd-147 1.07E+02 W-187 7.29E+03 Np-239 4.37E+OO Notes:

CY-BY-170-301 Revision 15 Page 154 of 188 Table 4-23 (Continued)

Infant Grass-Goat-Milk Dose Factors Liver TB d o IY Th "d

K"d 1yro1 1 ney L ung 6.05E+06 2.45E+06 6.09E+06 O.OOE+OO O.OOE+OO 1.68E+07 6.12E+06 1.46E+07 1.24E+08 O.OOE+OO 2.59E+02 1.66E+02 6.30E+02 1.89E+03 O.OOE+OO 2.29E+07 1.03E+07 2.57E+07 1.67E+08 O.OOE+OO 1.13E-10 7.62E-11 2.74E-10 8.13E-10 O.OOE+OO 1.63E+05 1.35E+05 3.30E+05 1.12E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.25E+06 1.17E+06 1.84E+06 7.81 E+06 O.OOE+OO 9.32E+06 3.74E+06 1.04E+09 1.02E+07 O.OOE+OO 3.85E+09 1.69E+09 1.26E+12 4.49E+09 O.OOE+OO 3.49E+OO 1.24E+OO 1.64E+02 3.90E+OO O.OOE+OO 6.35E+07 1.86E+07 1.15E+10 7.46E+07 O.OOE+OO 4.05E-11 1.44E-11 9.44E-10 4.53E-11 O.OOE+OO 2.70E+05 9.83E+04 2.42E+07 3.01E+05 O.OOE+OO 2.04E+11 2.06E+10 O.OOE+OO 5.25E+10 2.15E+10 1.74E+10 6.49E+09 O.OOE+OO 6.93E+09 1.42E+09 1.81 E+11 1.28E+10 O.OOE+OO 4.85E+10 1.96E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.41E-11 1.49E-09 O.OOE+OO 2.05E-11 2.07E-11 2.89E+04 1.49E+06 O.OOE+OO 6.87E+03 1.78E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.92E+OO 4.95E-01 O.OOE+OO O.OOE+OO O.OOE+OO 7.62E-12 1.82E-12 O.OOE+OO O.OOE+OO O.OOE+OO 3.17E+03 3.73E+02 O.OOE+OO 9.78E+02 O.OOE+OO 3.15E+04 3.60E+OO O.OOE+OO 9.19E+OO O.OOE+OO 1.14E+05 1.56E+04 O.OOE+OO 4.62E+04 O.OOE+OO 6.67E+01 8.84E+OO O.OOE+OO 2.48E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.09E+02 6.70E+OO O.OOE+OO 4.22E+01 O.OOE+OO 5.07E+03 1.75E+03 O.OOE+OO O.OOE+OO O.OOE+OO 3.91 E-01 2.21 E-01 O.OOE+OO 7.BOE-01 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3*

GILLI 8.62E+06 2.04E+07 1.63E+04 3.99E+07 2.61 E-08 2.74E+06 O.OOE+OO 4.62E+06 2.00E+06 1.37E+08 2.83E+OO 1.07E+07 4.19E-11 9.76E+04 5.54E+08 2.64E+08 5.65E+08 O.OOE+OO 3.26E-06 7.11E+06 O.OOE+OO O.OOE+OO 2.26E+04 1.29E-06 1.64E+06 1.84E+05 1.60E+07 9.41E+04 O.OOE+OO 6.93E+04 2.98E+05 1.13E+04

Nuclide Bone H-3 O.OOE+OO C-14 3.33E+05 Na-24 1.45E-03 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 2.93E+08 Fe-59 2.65E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.89E+09 Ni-65 O.OOE+OO Cu-64 O.OOE+OO Zn-65 3.56E+08 Zn-69 O.OOE+OO Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 3.01E+08 Sr-90 1.43E+10 Sr-91 1.43E-10 Sr-92 O.OOE+OO Y-90 1.08E+02 Y-91M O.OOE+OO Y-91 1.13E+06 Y-92 O.OOE+OO Y-93 4.39E-12 Zr-95 1.87E+06 Zr-97 2.04E-05 Nb-95 2.. 30E+06 Mo-99 O.OOE+OO Tc-99M O.OOE+OO Tc-101 O.OOE+OO Ru-103 1.05E+08 Ru-105 O.OOE+OO Ru-106 2.80E+09 Ag-110M 6.68E+06 Table 4-24 CY-BY-170-301 Revision 15 Page 155 of 188 Adult Grass-Cow-Meat Dose Factors Liver T Body Thyroid Kidney Lung 1.85E+02 1.85E+02 1.85E+02 1.85E+02 1.85E+02 6.66E+04 6.66E+04 6.66E+04 6.66E+04 6.66E+04 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 O.OOE+OO 7.04E+03 4.21E+03 1.55E+03 9.34E+03 9.18E+06 1.75E+06 O.OOE+OO 2.73E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.03E+08 4.72E+07 O.OOE+OO O.OOE+OO 1.13E+08 6.24E+08 2.39E+08 O.OOE+OO O.OOE+OO 1.74E+08 1.82E+07 4.09E+07 O.OOE+OO O.OOE+OO O.OOE+OO 7.52E+07 1.66E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.31 E+08 6.33E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.52E-07 1.18E-07 O.OOE+OO 6.36E-07 O.OOE+OO 1.13E+09 5.12E+08 O.OOE+OO 7.57E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.88E+08 2.28E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.65E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.87E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.79E-12 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.91E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.03E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.21 E-13 O.OOE+OO O.OOE+OO O.OOE+OO 6.01E+05 4.07E+05 O.OOE+OO 9.43E+05 O.OOE+OO 4.12E-06 1.88E-06 O.OOE+OO 6.22E-06 O.OOE+OO 1.28E+06 6.89E+05 O.OOE+OO 1.27E+06 O.OOE+OO 9.93E+04 1.89E+04 O.OOE+OO 2.25E+05 O.OOE+OO 1.22E-20 1.56E-19 O.OOE+OO 1.85E-19 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.53E+07 O.OOE+OO 4.01E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.54E+08 O.OOE+OO 5.40E+09 O.OOE+OO 6.18E+06 3.67E+06 O.OOE+OO 1.22E+07 O.OOE+OO GI-LLI 1.85E+02 6.66E+04 1.45E-03 1.77E+06 2.81 E+07 O.OOE+OO 1.16E+08 2.08E+09 3.70E+08 1.41 E+09 2.73E+07 O.OOE+OO 2.15E-05 7.13E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.63E+07 O.OOE+OO O.OOE+OO 4.83E+07 3.59E+08 6.83E-10 O.OOE+OO 1.15E+06 O.OOE+OO 6.23E+08 O.OOE+OO 1.39E-07 1.91 E+09 1.28E+OO 7.78E+09 2.30E+05 7.23E-18 O.OOE+OO 1.23E+10 O.OOE+OO 1.81 E+11 2.52E+09

Nuclide Bone Te-125M 3.59E+08 Te-127M 1.12E+09 Te-127 2.50E-10 Te-129M 1.13E+09 Te-129 O.OOE+OO Te-131M 4.49E+02 Te-131 O.OOE+OO Te-132 1.40E+06 1-130 2.03E-06 1-131 1.07E+07 1-132 O.OOE+OO 1-133 3.70E-01 1-134 O.OOE+OO 1-135 4.66E-17 Cs-134 6.58E+08 Cs-136 1.20E+07 Cs-137 8.72E+08 Cs-138 O.OOE+OO Ba-139 O.OOE+OO Ba-140 2.88E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 3.76E-02 La-142 O.OOE+OO Ce-141 1.40E+04 Ce-143 1.99E-02 Ce-144 1.46E+06 Pr-143 2.10E+04 Pr-144 O.OOE+OO Nd-147 7.21 E+03 W-187 2.07E-02 Np-239 2.57E-01 Notes:

Table 4-24 (Continued)

CY-BY-170-301 Revision 15 Page 156 of 188 Adult Grass-Cow-Meat Dose Factors Liver T Body Thyroid Kidney Lung 1.30E+08 4.81 E+07 1.08E+08 1.46E+09 O.OOE+OO 3.99E+08 1.36E+08 2.85E+08 4.53E+09 O.OOE+OO 8.98E-11 5.41E-11 1.85E-10 1.02E-09 O.OOE+OO 4.23E+08 1.79E+08 3.89E+08 4.73E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.20E+02 1.83E+02 3.48E+02 2.23E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.03E+05 8.48E+05 9.98E+05 8.70E+06 O.OOE+OO 5.98E-06 2.36E-06 5.07E-04 9.33E-06 O.OOE+OO 1.54E+07 8.80E+06 5.03E+09 2.63E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.43E-01 1.96E-01 9.45E+01 1.12E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.22E-16 4.50E-17 8.04E-15 1.95E-16 O.OOE+OO 1.57E+09 1.28E+09 O.OOE+OO 5.07E+08 1.68E+08 4.73E+07 3.40E+07 O.OOE+OO 2.63E+07 3.61E+06 1.19E+09 7.81 E+08 O.OOE+OO 4.05E+08 1.35E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.61E+04 1.88E+06 O.OOE+OO 1.23E+04 2.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E-02 5.01E-03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.49E+03 1.08E+03 O.OOE+OO 4.41E+03 O.OOE+OO 1.47E+01 1.63E-03 O.OOE+OO 6.47E-03 O.OOE+OO 6.09E+05 7.83E+04 O.OOE+OO 3.61 E+05 O.OOE+OO 8.42E+03 1.04E+03 O.OOE+OO 4.86E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.33E+03 4.98E+02 O.OOE+OO 4.87E+03 O.OOE+OO 1.73E-02 6.04E-03 O.OOE+OO O.OOE+OO O.OOE+OO 2.53E-02 1.40E-02 O.OOE+OO 7.90E-02 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

Gl-LLI 1.43E+09 3.74E+09 1.97E-08 5.71E+09 O.OOE+OO 2.18E+04 O.OOE+OO 4.27E+07 5.15E-06 4.05E+06 O.OOE+OO 5.78E-01 O.OOE+OO 1.38E-16 2.74E+07 5.37E+06 2.31E+07 O.OOE+OO O.OOE+OO 5.92E+07 O.OOE+OO O.OOE+OO 1.39E+03 O.OOE+OO 3.63E+07 5.49E+02 4.93E+08 9.20E+07 O.OOE+OO 4.00E+07 5.66E+OO 5.19E+03

N l"d UCI e B one H-3 O.OOE+OO C-14 2.81 E+05 Na-24 1.16E-03 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 2.38E+08 Fe-59 2.12E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 1.52E+09 Ni-65 O.OOE+OO Cu-64 O.OOE+OO Zn-65 2.50E+08 Zn-69 O.OOE+OO Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 2.54E+08 Sr-90 9.89E+09 Sr-91 1.21E-10 Sr-92 O.OOE+OO Y-90 9.13E+01 Y-91M O.OOE+OO Y-91 9.54E+05 Y-92 O.OOE+OO Y-93 3.71E-12 Zr-95 1.50E+06 Zr-97 1.70E-05 Nb-95 1.80E+06 Mo-99 O.OOE+OO Tc-99M O.OOE+OO Tc-101 O.OOE+OO Ru-103 8.56E+07 Ru-105 O.OOE+OO Ru-106 2.36E+09 AQ-110M 5.06E+06 Table 4-25 CY-BY-170-301 Revision 15 Page 157 of 188 Teen Grass-Cow-Meat Dose Factors L"

T B d Th "d

K"d 1ver o IY 1yro1 1 ney L ung 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 O.OOE+OO 5.63E+03 3.13E+03 1.23E+03 8.04E+03 7.00E+06 1.39E+06 O.OOE+OO 2.09E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.69E+08 3.94E+07 O.OOE+OO O.OOE+OO 1.07E+08 4.95E+08 1.91E+08 O.OOE+OO O.OOE+OO 1.56E+08 1.41 E+07 3.24E+07 O.OOE+OO O.OOE+OO O.OOE+OO 5.83E+07 1.31 E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.07E+08 5.15E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.06E-07 9.68E-08 O.OOE+OO 5.21 E-07 O.OOE+OO 8.69E+08 4.05E+08 O.OOE+OO 5.56E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.08E+08 1.91 E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.28E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.80E-12 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.46E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.56E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.02E-13 O.OOE+OO O.OOE+OO O.OOE+OO 4.74E+05 3.26E+05 O.OOE+OO 6.96E+05 O.OOE+OO 3.37E-06 1.55E-06 O.OOE+OO 5.10E-06 O.OOE+OO 9.98E+05 5.49E+05 O.OOE+OO 9.67E+05 O.OOE+OO 8.21E+04 1.57E+04 O.OOE+OO 1.88E+05 O.OOE+OO O.OOE+OO 1.24E-19 O.OOE+OO 1.43E-19 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.66E+07 O.OOE+OO 3.02E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.97E+08 O.OOE+OO 4.55E+09 O.OOE+OO 4.79E+06 2.91 E+06 O.OOE+OO 9.13E+06 O.OOE+OO GILLI 1.10E+02 5.62E+04 1.16E-03 9.46E+05 1.44E+07 O.OOE+OO 7.31E+07 1.17E+09 1.94E+08 7.60E+08 1.71 E+07 O.OOE+OO 1.60E-05 3.68E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.03E+07 O.OOE+OO O.OOE+OO 3.03E+07 2.26E+08 5.47E-10 O.OOE+OO 7.53E+05 O.OOE+OO 3.91E+08 O.OOE+OO 1.13E-07 1.09E+09 9.11E-01 4.27E+09 1.47E+05 6.29E-18 O.OOE+OO 7.15E+09 O.OOE+OO 1.13E+11 1.35E+09

Table 4-25 (Continued)

CY-BY-170-301 Revision 15 Page 158 of 188 Teen Grass-Cow-Meat Dose Factors N

l"d UCI e B one L" 1ver TB d o IY Th "d

1yro1 K"d 1 ney L ung Te-125M 3.03E+08 1.09E+08 4.06E+07 8.47E+07 O.OOE+OO O.OOE+OO Te-127M 9.41E+08 3.34E+08 1.12E+08 2.24E+08 3.82E+09 O.OOE+OO Te-127 2.12E-10 7.53E-11 4.57E-11 1.46E-10 8.60E-10 O.OOE+OO Te-129M 9.49E+08 3.52E+08 1.50E+08 3.06E+08 3.97E+09 O.OOE+OO Te-129 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Te-131M 3.75E+02 1.80E+02 1.50E+02 2.70E+02 1.87E+03 O.OOE+OO Te-131 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Te-132 1.14E+06 7.24E+05 6.81E+05 7.63E+05 6.94E+06 O.OOE+OO 1-130 1.63E-06 4.72E-06 1.88E-06 3.85E-04 7.27E-06 O.OOE+OO 1-131 8.92E+06 1.25E+07 6.71 E+06 3.64E+09 2.15E+07 O.OOE+OO 1-132 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1-133 3.09E-01 5.25E-01 1.60E-01 7.32E+01 9.20E-01 O.OOE+OO 1-134 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1-135 3.79E-17 9.75E-17 3.61 E-17 6.27E-15 1.54E-16 O.OOE+OO Cs-134 5.23E+08 1.23E+09 5.71E+08 O.OOE+OO 3.91E+08 1.49E+08 Cs-136 9.34E+06 3.68E+07 2.47E+07 O.OOE+OO 2.00E+07 3.15E+06 Cs-137 7.24E+08 9.63E+08 3.36E+08 O.OOE+OO 3.28E+08 1.27E+08 Cs-138 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Ba-139 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Ba-140 2.38E+07 2.91 E+04 1.53E+06 O.OOE+OO 9.88E+03 1.96E+04 Ba-141 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Ba-142 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO La-140 3.09E-02 1.52E-02 4.04E-03 O.OOE+OO O.OOE+OO O.OOE+OO La-142 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Ce-141 1.18E+04 7.87E+03 9.04E+02 O.OOE+OO 3.70E+03 O.OOE+OO Ce-143 1.67E-02 1.22E+01 1.36E-03 O.OOE+OO 5.46E-03 O.OOE+OO Ce-144 1.23E+06 5.08E+05 6.60E+04 O.OOE+OO 3.04E+05 O.OOE+OO Pr-143 1.77E+04 7.05E+03 8.79E+02 O.OOE+OO 4.10E+03 O.OOE+OO Pr-144 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Nd-147 6.35E+03 6.90E+03 4.14E+02 O.OOE+OO 4.05E+03 O.OOE+OO W-187 1.73E-02 1.41E-02 4.94E-03 O.OOE+OO O.OOE+OO O.OOE+OO Np-239 2.25E-01 2.12E-02 1.18E-02 O.OOE+OO 6.66E-02 O.OOE+OO Notes:

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GILLI 8.95E+08 2.35E+09 1.64E-08 3.56E+09 O.OOE+OO 1.44E+04 O.OOE+OO 2.29E+07 3.63E-06 2.47E+06 O.OOE+OO 3.97E-01 O.OOE+OO 1.0BE-16 1.53E+07 2.96E+06 1.37E+07 O.OOE+OO O.OOE+OO 3.67E+07 O.OOE+OO O.OOE+OO 8.73E+02 O.OOE+OO 2.25E+07 3.66E+02 3.09E+08 5.81 E+07 O.OOE+OO 2.49E+07 3.82E+OO 3.41 E+03

N l"d UCI e B one H-3 O.OOE+OO C-14 5.29E+05 Na-24 1.84E-03 Cr-51 O.OOE+OO Mn-54 O.OOE+OO Mn-56 O.OOE+OO Fe-55 4.57E+08 Fe-59 3.76E+08 Co-58 O.OOE+OO Co-60 O.OOE+OO Ni-63 2.91E+09 Ni-65 O.OOE+OO Cu-64 O.OOE+OO Zn-65 3.75E+08 Zn-69 O.OOE+OO Br-83 O.OOE+OO Br-84 O.OOE+OO Br-85 O.OOE+OO Rb-86 O.OOE+OO Rb-88 O.OOE+OO Rb-89 O.OOE+OO Sr-89 4.81 E+08 Sr-90 1.57E+10 Sr-91 2.26E-10 Sr-92 O.OOE+OO Y-90 1.73E+02 Y-91M O.OOE+OO Y-91 1.80E+06 Y-92 O.OOE+OO Y-93 6.97E-12 Zr-95 2.67E+06 Zr-97 3.16E-05 Nb-95 3.11E+06 Mo-99 O.OOE+OO Tc-99M O.OOE+OO Tc-101 O.OOE+OO Ru-103 1.55E+08 Ru-105 O.OOE+OO Ru-106 4.44E+09 Ag-110M 8.39E+06 Table 4-26 CY-BY-170-301 Revision 15 Page 159 of 188 Child Grass-Cow-Meat Dose Factors L"

TB d Th "d

K"d 1ver O IY 1vro1 1 ney L ung 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 O.OOE+OO 8.78E+03 4.87E+03 1.33E+03 8.90E+03 8.01 E+06 2.13E+06 O.OOE+OO 2.25E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.42E+08 7.51 E+07 O.OOE+OO O.OOE+OO 1.37E+08 6.08E+08 3.03E+08 O.OOE+OO O.OOE+OO 1.76E+08 1.64E+07 5.03E+07 O.OOE+OO O.OOE+OO O.OOE+OO 6.93E+07 2.04E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.56E+08 9.91E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.77E-07 1.67E-07 O.OOE+OO 6.68E-07 O.OOE+OO 1.00E+09 6.22E+08 O.OOE+OO 6.30E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.78E+08 3.55E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.37E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.15E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.54E-12 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.62E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.91E-13 O.OOE+OO O.OOE+OO O.OOE+OO 5.86E+05 5.22E+05 O.OOE+OO 8.39E+05 O.OOE+OO 4.57E-06 2.70E-06 O.OOE+OO 6.56E-06 O.OOE+OO 1.21 E+06 8.64E+05 O.OOE+OO 1.14E+06 O.OOE+OO 1.14E+05 2.82E+04 O.OOE+OO 2.44E+05 O.OOE+OO 1.18E-20 1.96E-19 O.OOE+OO 1.72E-19 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.95E+07 O.OOE+OO 3.90E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.54E+08 O.OOE+OO 5.99E+09 O.OOE+OO 5.67E+06 4.53E+06 O.OOE+OO 1.06E+07 O.OOE+OO GILLI 1.34E+02 1.06E+05 1.84E-03 4.66E+05 6.72E+06 O.OOE+OO 4.49E+07 6.34E+08 9.59E+07 3.84E+08 1.05E+07 O.OOE+OO 1.30E-05 1.76E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.72E+07 O.OOE+OO O.OOE+OO 1.86E+07 1.40E+08 5.00E-10 O.OOE+OO 4.92E+05 O.OOE+OO 2.40E+08 O.OOE+OO 1.04E-07 6.11E+08 6.93E-01 2.24E+09 9.44E+04 6.72E-18 O.OOE+OO 4.00E+09 O.OOE+OO 6.90E+10 6.74E+08

N l"d UCI e B one Te-125M 5.70E+08 Te-127M 1.77E+09 Te-127 3.99E-10 Te-129M 1.79E+09 Te-129 O.OOE+OO Te-131M 6.97E+02 Te-131 O.OOE+OO Te-132 2.09E+06 1-130 2.92E-06 1-131 1.65E+07 1-132 O.OOE+OO 1-133 5.75E-01 1-134 O.OOE+OO 1-135 6.86E-17 Cs-134 9.22E+08 Cs-136 1.61E+07 Cs-137 1.33E+09 Cs-138 O.OOE+OO Ba-139 O.OOE+OO Ba-140 4.39E+07 Ba-141 O.OOE+OO Ba-142 O.OOE+OO La-140 5.66E-02 La-142 O.OOE+OO Ce-141 2.22E+04 Ce-143 3.14E-02 Ce-144 2.32E+06 Pr-143 3.34E+04 Pr-144 O.OOE+OO Nd-147 1.19E+04 W-187 3.21 E-02 Np-239 4.23E-01 Notes:

Table 4-26 (Continued)

CY-BY-170-301 Revision 15 Page 160 of 188 Child Grass-Cow-Meat Dose Factors L"

TB d Th "d

K"d 1ver O IY 1yro1 1 ney L ung 1.54E+08 7.59E+07 1.60E+08 O.OOE+OO O.OOE+OO 4.78E+08 2.11E+08 4.24E+08 5.06E+09 O.OOE+OO 1.08E-10 8.56E-11 2.76E-10 1.14E-09 O.OOE+OO 5.00E+08 2.78E+08 5.77E+08 5.25E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.41E+02 2.57E+02 4.96E+02 2.33E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.23E+05 1.12E+06 1.34E+06 8.57E+06 O.OOE+OO 5.89E-06 3.04E-06 6.49E-04 8.81 E-06 O.OOE+OO 1.66E+07 9.45E+06 5.50E+09 2.73E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.10E-01 2.69E-01 1.32E+02 1.18E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.23E-16 5.84E-17 1.09E-14 1.89E-16 O.OOE+OO 1.51E+09 3.19E+08 O.OOE+OO 4.69E+08 1.68E+08 4.43E+07 2.87E+07 O.OOE+OO 2.36E+07 3.52E+06 1.28E+09 1.88E+08 O.OOE+OO 4.16E+08 1.50E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.84E+04 2.56E+06 O.OOE+OO 1.25E+04 2.29E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E-02 6.67E-03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.11 E+04 1.64E+03 O.OOE+OO 4.85E+03 O.OOE+OO 1.70E+01 2.46E-03 O.OOE+OO 7.14E-03 O.OOE+OO 7.26E+05 1.24E+05 O.OOE+OO 4.02E+05 O.OOE+OO 1.00E+04 1.66E+03 O.OOE+OO 5.44E+03 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.65E+03 7.47E+02 O.OOE+OO 5.29E+03 O.OOE+OO 1.90E-02 8.52E-03 O.OOE+OO O.OOE+OO O.OOE+OO 3.04E-02 2.14E-02 O.OOE+OO 8.79E-02 O.OOE+OO

1)

Units are m2 mrem/yr per µCi/sec.

2)

For H-3 and C-14, the units are mrem/yr per µCi/m3.

GILLI 5.50E+08 1.44E+09 1.56E-08 2.18E+09 O.OOE+OO 9.78E+03 O.OOE+OO 9.30E+06 2.76E-06 1.48E+06 O.OOE+OO 2.86E-01 O.OOE+OO 9.40E-17 8.16E+06 1.56E+06 7.99E+06 O.OOE+OO O.OOE+OO 2.22E+07 O.OOE+OO O.OOE+OO 5.52E+02 O.OOE+OO 1.38E+07 2.49E+02 1.89E+08 3.61 E+07 O.OOE+OO 1.53E+07 2.67E+OO 2.25E+03

3)

The infant age group is assumed to receive no dose through the meat ingestion pathway therefore no dose factors are supplied.

Table 4-27 Byron Station Characteristics LOCATION: 3.7 miles SSW of Byron, Illinois Characteristics of Elevated Release Point:

Not applicable (NA)

Diameter = __ m CY-BY-170-301 Revision 15 Page 161 of 188

1)
3)

Release Height= __ m Exit Speed

= _ms-1

2)
4)

Heat Content_Kcal s-1 Characteristics of Vent Stack Release Point

1)
3)

Release Height = 60.66 ma Exit Speed

= 13.00 ms-1a Characteristics of Ground Level Point

1)

Release Height= O m

2)
2)

Building Factor (D) =

60.6 ma Meteorological Data Diameter = 2.80 m A 250 ft Tower is Located 1036 m SW of vent stack release point Tower Data Used in Calculations Wind Speed Release Point and Direction Elevated Vent Ground

{NA) 250 ft 30 ft Differential Temperature (NA) 250-30 ft 250-30 ft a Used in calculating the meteorological and dose factors in Table 4-1 and Table 4-4.

CY-BY-170-301 Revision 15 Page 162 of 188 Table 4-28 Dose Factors for Noble Gases Beta Air Beta Skin Gamma Air Gamma Total Dose Factor Dose Factor Dose Factor Body Dose Factor Ni Li Mi Ki Nuclide (mrad/yr ~er (mrem/yr ~er (mrad/yr oer (mrem/yr ~er uCi/m3) uCi/m3) uCi/m3) uCi/m3)

Kr-83m 2.88E+02 1.93E+01 7.56E-02 Kr-85m 1.97E+03 1.46E+03 1.23E+03 1.17E+03 Kr-85 1.95E+03 1.34E+03 1.72E+01 1.61 E+01 Kr-87 1.03E+04 9.73E+03 6.17E+03 5.92E+03 Kr-88 2.93E+03 2.37E+03 1.52E+04 1.47E+04 Kr-89 1.06E+04 1.01E+04 1.73E+04 1.66E+04 Kr-90 7.83E+03 7.29E+03 1.63E+04 1.56E+04 Xe-131m 1.11E+03 4.76E+02 1.56E+02 9.15E+01 Xe-133m 1.48E+03 9.94E+02 3.27E+02 2.51E+02 Xe-133 1.05E+03 3.06E+02 3.53E+02 2.94E+02 Xe-135m 7.39E+02 7.11 E+02 3.36E+03 3.12E+03 Xe-135 2.46E+03 1.86E+03 1.92E+03 1.81E+03 Xe-137 1.27E+04 1.22E+04 1.51 E+03 1.42E+03 Xe-138 4.75E+03 4.13E+03 9.21 E+03 8.83E+03 Ar-41 3.28E+03 2.69E+03 9.30E+03 8.84E+03 Source: Table B-1 of US NRC Regulatory Guide 1.109

5.

TOTAL DOSE 5.1.

Total Dose Calculation Requirements CY-BY-170-301 Revision 15 Page 163 of 188 5.1.1.

Total Effective Dose Equivalent Limits; 10CFR20 and 40CFR190

1.

The Byron Station is required to determine the total dose to a member of the public due to all uranium fuel cycle sources in order to assess compliance with 40CFR 190 as part of demonstrating compliance with 1 OCFR20.

2.

The total dose for the uranium fuel cycle is the sum of doses due to radioactivity in airborne and liquid effluents and the doses due to direct radiation from contained sources at the nuclear power station. When evaluation of total dose is required for a station, the following contributions are summed:

A.

Doses due to airborne and liquid effluents from the station.

B.

Doses due to liquid effluents from nuclear power stations upstream.

C.

Doses due to any onsite radioactive waste storage facilities, if applicable.

D.

Doses due to ISFSI

3.

10CFR20 requires compliance to dose limits expressed as "Total Effective Dose Equivalent" (TEDE). Although annual dose limits in 1 OCFR20 are now expressed in terms of TEDEs, 40CFR190 limits remain stated as organ dose. The NRC continues to require 10CFR50 Appendix I and 40CFR190 doses to be reported in terms of organ dose and not TEDE. Due to the fact that organ dose limits set forth in 40CFR 190 are substantially lower than those of 1 OCFR20 (25 mrem/yr vs. 100 mrem/yr), the NRC has stated that demonstration of compliance with the dose limits in 40CFR190 will be deemed as demonstration of compliance with the dose limits of 10CFR20 for most facilities (Reference 104). In addition to compliance with 40CFR190, it may be necessary for a nuclear power plant to address dose from on-site activity by members of the public.

5.1.2.

1.
2.
3.
4.

5.1.3.

1.
2.

5.2.

1.

5.2.1.

ISFSI CY-BY-170-301 Revision 15 Page 164 of 188 10CFR72.104 dose limits are the same as those specified by 40CFR190.

ISFSI dose contribution is in the form of direct radiation as no liquid or gas releases are expected to occur. The 10CFR72.212 report prepared in accordance with ISFSI requirements assumes a certain array of casks exists on the pad. The dose contribution from this array of casks in combination with historical uranium fuel cycle operations prior to ISFSI operations was analyzed to be within the 40CFR 190 and 10CFR72.104 limits, and is documented in Holtec Report No. Hl-2146048, Dose Versus Distance from a HI-STORM 100S version B containing the MPC-32 for Byron/Braidwood.

If the dose limits of 40CFR190 or 10CFR72.104 are exceeded, a special report to the NRC as well as an appropriate request for exemption/variance is required to be submitted to the NRC.

The requirement that the dose limits of 10CFR72.104 apply to "any real individual" is controlled for ISFSI activities in the ISFSI 72.212 report. Therefore, for the purposes of analyzing dose from the ISFSI, the member of the public as defined in 40CFR190 is the same as the "real individual" identified in the 72.212 report.

Total Dose Calculation Methodology In addition to the total body, skin and single organ dose assessments previously described, an additional assessment is required. The additional assessment addresses radiation dose due to radioactivity contained within the nuclear power station and its structures.

Pressurized water reactors have the potential to affect off-site doses from contained sources of radioactivity, primarily due to gamma rays associated with radioactive material contained in onsite radwaste and radioactive material storage facilities.

Onsite Radwaste and Rad Material Storage Facilities A 1 OCFR50.59 analysis is required for radwaste storage facilities.

Process Waste Storage Facilities A.

Interim Radwaste Storage Facility (IRSF) structure B.

Concrete vaults containing radwaste liners

5.2.2.

1.
2.

5.2.3.

5.2.4.

1.

5.3.

1.

DAW Storage Facilities CY-BY-170-301 Revision 15 Page 165 of 188 Dry Active Waste (DAW) facilities (may include Butler buildings/warehouses)

Seavans or other temporary warehouses Replaced Steam Generator Storage Facilities ISFSI Facilities Independent spent fuel storage installation facilities.

Methodology The external total body dose is comprised of the following parts:

A.

Total body dose due to noble gas radionuclides in gaseous effluents (Section 4.2.2.3),

B.

Dose due to other contained sources and C.

Total body dose due to radioactivity deposited on the ground (Section 4.2.3.1 ).

2.

The external total body dose due to radioactivity deposited on the ground is accounted for in the determination of the non-noble gas dose and is considered in section 5.7.

3.

The total external total body dose, DEx, is given by:

(5-1)

Total External Total Body Dose

[mrem]

Total external total body dose due to irradiation by external sources at the location of interest.

Noble Gas Total Body Dose

[mrem]

External total body dose due to gamma radiation from noble gas radionuclides released in gaseous effluents at the location of interest. See Section 4.2.2.3.

Dose From On-Site Storage Facilities

[mrem]

External total body dose due to gamma radiation from on-site storage facilities at the location of interest. See Section 5.2.

CY-BY-170-301 Revision 15 Page 166 of 188 5.4.

Total Dose

1.

The total dose, D Tot, in the unrestricted area to a member of the public due to plant operations is given by:

where:

orot DNNG aJ 5.5.

5.5.1.

1.

5.5.2.

1.

D Tot = oEx + oLlq + oNNG

  • I
  • I (5-2)

Total Dose To Member of Public

[mrem]

Total off-site dose to a member of public due to plant operations.

Total External Total Body Dose

[mrem]

Total body dose due to external exposure to noble gases, N-16 skyshine and on-site storage facilities.

Liquid Effluent Dose

[mrem]

Dose due to liquid effluents to age group a and organ j. The age group and organ with the highest dose from liquid effluents is used.

Non-Noble Gaseous Effluent Dose

[mrem]

Dose due to non-noble gaseous effluents to age group a and organ j. The age group and organ with the highest dose from non-noble gas effluents is used.

COMPLIANCE TO TOTAL DOSE LIMITS Total Effective Dose Equivalent Limit - 1 OCFR20 Compliance Each station's RE limits the Total Effective Dose Equivalent (TEDE) to an annual limit of 100 mrem, as required by 1 OCFR20.1301 (a)(1 ). Demonstration of compliance with the limits of 40CFR 190 (per Section 4.2.2) will be considered to demonstrate compliance with the 100 mrem/year limit.

Dose to a Member of the Public in the Unrestricted Area The NRC has stated that demonstration of compliance with the limits of 40CFR190 or with the design objectives of Appendix I to 10CFR50 will be deemed to demonstrate compliance with the limits of 10CFR20.1301(a)(1).

Power reactors that comply with Appendix I may also have to demonstrate that they are within the 25 mrem limit of 40CFR190 (See Reference 104).

5.5.3.

1.
2.
3.

5.5.4.

1.

Dose to a Member of the Public in the Restricted Area CY-BY-170-301 Revision 15 Page 167 of 188 In August of 1995, a revision to 1 OCFR20 was implemented that changed the definition of a member of the public. As a result, for each nuclear station, estimated doses were calculated for a member of the public who enters the site boundary, but is not authorized for unescorted access to the protected area of the site and does not enter any radiologically posted areas on the site. Realistic assumptions were made for occupancy times and locations visited while within the site boundary.

These evaluations indicate that the doses estimated for these members of the public are well within the 1 OCFR20 limits. These dose evaluations will be performed annually and if necessary, a model will be developed and included in the ODCM.

Evaluation of the 40CFR 190 dose is used to demonstrate compliance to 1 OCFR20 and satisfy station TRM and Technical Specifications (see ODCM Part 1)

Total Dose due to the Uranium Fuel Cycle (40CFR190)

RE and 40CFR190 limit the annual (calendar year) dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources to the following:

A.

Less than or equal to 25 mrem to the total body.

B.

Less than or equal to 25 mrem to any organ except the thyroid.

C.

Less than or equal to 75 mrem to the thyroid.

2.

Total Dose Components A.

This requirement includes the total dose from operations at the nuclear power station. This includes doses due to radioactive effluents (airborne and liquid) and dose due to direct radiation from non-effluent sources (e.g., sources contained in systems on site). It also includes dose due to plants under consideration, neighboring plants and dose due to other facilities in the uranium fuel cycle.

CY-BY-170-301 Revision 15 Page 168 of 188

3.

The operations comprising the uranium fuel cycle are specified in 40CFR190.02(b). The following are included to the extent that they directly support the production of electrical power for public use utilizing nuclear energy:

A.

Milling of uranium ore.

B.

Chemical conversion of uranium.

C.

Isotopic enrichment of uranium.

D.

Fabrication of uranium fuel.

E.

Generation of electricity by a light-watered-cooled nuclear power plant using uranium fuel.

F.

Reprocessing of spent uranium fuel.

4.

Excluded are:

A.

Mining operations.

B.

Operations at waste disposal sites.

C.

Transportation of any radioactive material in support of these operations.

D.

The re-use of recovered non-uranium special nuclear and by-product materials from the cycle.

5.6.

When Compliance Assessment is Required

1.

Compliance with the 40CFR190 regulations is now required as part of demonstration of compliance to 1 OCFR20 regulations per 1 OCFR20.1301 (d).

2.

The dose due to the uranium fuel cycle is determined by equation 5-2

CY-BY-170-301 Revision 15 Page 169 of 188

6.

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

1.

The radiological environmental monitoring program for the environs around Byron Station is given in Table 6-1.

2.

Figures 6-1 through 6-4 show sampling and monitoring locations.

Exposure Pathway and/or Sample

1. Airborne Radioiodine and Particulates Table 6-1 Radiological Environmental Monitoring Program Sampling or Monitoring Locations
a.
b.

C.

Indicators-Near Field BY-21 BY-22 BY-23 BY-24 Indicators-Far Field BY-01, Byron BY-04, Paynes Pt.

BY-06, Oregon Controls BY-08, Leaf River Sampling or Collection Frequency Continuous sampler operation with particulate sample collection weekly, or more frequently if required by dust loading, and radioiodine canister collection weekly.

CY-BY-170-301 Revision 15 Page 170 of 188 Type or Frequency of Analysis Radioiodine Canister:

1-131 analysis weekly on near field and control samples.1 Particulate Sampler:

Gross beta analysis followin~ weekly filter change and gamma isotopic analysis 3

quarterly on composite filters by location on near field and control samples.

Exposure Pathway and/or Sample

2. Direct Radiation (Two dosimeters at each location)

Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations

a.

Indicators-Inner Ring BY-101-1 BY-101-2 BY-102-1 BY-102-2 BY-103-1 BY-103-2 BY-103-3 BY-104-1 BY-104-2 BY-104-3 BY-105-1 BY-105-2 BY-106-1 BY-106-2 BY-107-1 BY-107-2 BY-107-3 BY-108-1 BY-108-2 BY-109-1 BY-109-2 BY-110-1 BY-110-2 BY-111-3 BY-111-4 BY-112-3 BY-112-4 Sampling or Collection Frequency Quarterly CY-BY-170-301 Revision 15 Page 171 of 188 Type or Frequency of Analysis Gamma Dose Quarterly

Exposure Pathway and/or Sample

2.

Direct Radiation (cont'd)

Table 6-1 (Cont.)

CY-BY-170-301 Revision 15 Page 172 of 188 Radiological Environmental Monitoring Program Sampling or Monitoring Locations Indicators-Inner Ring (cont'd)

BY-113-1 BY-113-2 BY-114-1 BY-114-2 BY-115-1 BY-115-2 BY-116-1 BY-116-2 BY-116-3

b.

Indicators-Outer Ring BY-201-3 BY-201-4 BY-202-1 BY-202-2 BY-203-1 BY-203-2 BY-204-1 BY-204-2 BY-205-1 BY-205-2 BY-206-1 BY-206-2 BY-207-1 BY-207-2 Sampling or Collection Frequency Quarterly Type or Frequency of Analysis Gamma Dose Quarterly

Exposure Pathway and/or Sample

2. Direct Radiation (cont'd)

Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations Indicators-Outer Ring (cont'd)

BY-208-1 BY-208-2 BY-209-1 BY-209-4 BY-210-3 BY-210-4 BY-211-1 BY-211-4 BY-212-1 BY-212-4 BY-213-1 BY-213-4 BY-214-1 BY-214-4 BY-215-1 BY-215-4 BY-216-1 BY-216-2

c.

Indicators At all airborne indicator locations listed in Section 1 Sampling or Collection Frequency Quarterly CY-BY-170-301 Revision 15 Page 173 of 188 Type of Frequency of Analysis Gamma Dose Quarterly

Exposure Pathway and/or Sample

2. Direct Radiation (cont'd)

Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations

d.

Control At the control airborne location listed in Section 1

e.

Special Interest BY-301-1 BY-301-2 BY-309-1 BY-309-2 BY-309-3 BY-309-4 BY-314-2 Sampling or Collection Frequency Quarterly Quarterly CY-BY-170-301 Revision 15 Page 174 of 188 Type of Frequency of Analysis Gamma dose quarterly Gamma dose quarterly

Exposure Pathway and/or Sample

3. Waterborne Ground/Well Drinking Surface Sediment Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations

a.

Indicators BY-14-1, 3200 German Church Rd BY-18-1, Calhoun Well BY-32, Wolford Well BY-35, Vancko Well BY-38, Storz Well BY-37, Alexander Well There is no drinking water pathway within 6.2 mi downstream of the station.

a.

Indicators BY-12, Oregon Pool of Rock River, Downstream of Discharge

b.

Control BY-29, Byron, Upstream of Intake

a.

Indicators BY-12, Oregon Pool of Rock River, Downstream of Discharge

b.

Control BY-34, Rock River Upstream of discharge Sampling or Collection Frequency Quarterly Weekly grab samples.

Semiannually CY-BY-170-301 Revision 15 Page 175 of 188 Type or Frequency of Analysis Gamma isotopic3 and tritium analysis quarterly.

Gross beta and ~amma isotopic analysis on monthly composite; tritium analysis on quarterly composite.

Gamma isotopic 3

analysis semiannually.

Exposure Pathway and/or Sample

4. Ingestion Milk Fish Food Products Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations Sampling or Collection Frequency

a.

Indicators Biweekly: May through October; monthly:

November through April.

BY-20-1 R. Snodgrass.Dairy Farm

b.

Controls BY-26-2, Akins Dairy

a.

Indicator BY-31, Rock River in vicinity of Discharge Two times annually

b.

Control BY-29, Byron, Upstream of Intake

a.

lndie_ators Annually Two samples from each of the four major quadrants within 6.2 miles of the station.

CY-BY-170-301 Revision 15 Page 176 of 188 Type or Frequency of Analysis Gamma isotopic3 and 1-131 analysis 4 on each sample.

Gamma isotopic3 analysis on edible portions.

Gamma isotopic3 analysis on each sample.

Exposure Pathway and/or Sample Food Products (cont'd)

Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Sampling or Monitoring Locations

b.

Control Sampling or Collection Frequency Annually Two samples within 9.3 to 18.6 miles of the station.

Sample locations for food products may vary based on availability and therefore are not required to be identified here but shall be taken.

CY-BY-170-301 Revision 15 Page 177 of 188 Type of Frequency of Analysis Gamma lsotopic3 analysis on each sample.

Table 6-1 (Cont'd)

Radiological Environmental Monitoring Program CY-BY-170-301 Revision 15 Page 178 of 188 1Far field samples are not required to be analyzed, unless the respective near field sample results are inconsistent with previous measurements and radioactivity is confirmed as having its origin in airborne effluents from the station, or at the discretion of the Chemistry Manager.

2Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.

3Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the station.41-131 analysis means the analytical separation and counting procedure are specific for this radionuclide.

REFERENCE':

UNITED STATES GEOLOGIC SURVEY STILLMAN VALLEY QUADRANGLE, OR TOPOGRAPHIC, 7.5 MINUTES SERIES 1976 D

1/2 1 IIM 0

1/2 1 MILE H-J I

e AIR SAMPLING LOCATION OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGURE6-1 ONSITE AIR SAMPLING LOCATIONS and Unrestricted Area Boundary CY-BY-170-301 Revision 15 Page 179 of 188

AIR SAMPLING I.OCATION a

BYRON STA"IION 0

2 3

4 5 MllEI 0

2 4

5 I

101CM8 OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGUREtr2 OFFSITE AIR SAMPLING LOCATIONS Pagell6-12 CY-BY-170-301 Revision 15 Page 180 of 188

Figure 6.3a CY-BY-170-301 Revision 15 Page 181 of 188 Inner Ring and Special Interest Dosimeter Locations

Figure 6.3b Outer Ring Dosimeter Locations z

  • I
    • ~.. ___.

CY-BY-170-301 Revision 15 Page 182 of 188 I

II "D

~

fii

~

ii

E z*

EH

e FISH l!,,

MUC 0

SEDIMENT

+ WATER a BYRON STATJON

+

+14*1 18*1 1--------1 ROCK RIVER 0

2 3

4 0

4 I

OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGUREM INGESTION AND WATERBORNE EXPOSURE PATHWAY SAMPLE LOCATIONS C PLANT UQUIO DISCHARGE CY-BY-170-301 Revision 15 Page 183 of 188

Sampling Location Vent Stack BY-01 BY-04 BY-06 BY-08 BY-21 BY-22 BY-23 BY-24 BY-12 BY-29 BY-12 BY-34 BY-29 BY-31 BY-20-1 BY-26-2 BY-14-1 BY-18-1 BY-32 BY-35 BY-38 BY-37 BY-Control BY-Quad I BY-Quad2 BY-Quad 3 BY-Quad4 CY-BY-170-301 Revision 15 Page 184 of 188 Latitude/Longitude Positions ofREMP Samples Table 6-2 Latitude Longitude Distance Distance Direction Sector (deg)

(deg)

(km)

(mi)

(deg)

Desig Release (Reference) Point

! 42.07472 ! -89.28264 ! N/A NIA NIA NIA Air Sampling Stations 42.11762

-89.27993 4.77 2.96 3

A 42.01867

-89.22213 7.98 4.96 142 G

42.01577

-89.33010 7.63 4.74 211 K

42.12668

-89.39918 11.20 6.96 301 p

42.07908

-89.28213 0.49 0.30 5

A 42.07168

-89.27693 0.58 0.36 125 G

42.06585

-89.28230 0.98 0.61 178 J

42.06790

-89.29278 1.13 0.70 228 L

Surface Water 42.01717

-89.32603 7.33 4.55 209 K

42.11773

-89.27990 4.78 2.97 3

A Sediment 42.01717

-89.32603 7.33 4.55 209 K

42.09355

-89.32638 4.18 2.60 300 p

Fish 42.11773

-89.27990 4.78 2.97 3

A 42.09353

-89.32623 4.16 2.58 300 p

Milk 42.05898

-89.37455 7.80 4.85 257 M

42.12221

-89.51107 19.60 12.20 286 p

Well Water 42.06102

-89.27753 1.58 0.98 164 H

42.06578

-89.29051 1.19 0.74 213 K

42.07527

-89.31863 3.00 1.86 271 N

42.08097

-89.31802 3.01 1.87 283 p

42.08259

-89.32021 3.23 2.00 286 p

42.08225

-89.31928 3.14 1.95 285 p

Vegetation Varies by Varies by year Varies by Varies by Varies by year Varies by vear vear vear vear Varies by Varies by year Varies by Varies by Varies by year Varies by vear vear vear vear Varies by Varies by year Varies by Varies by Varies by year Varies by vear vear vear vear Varies by Varies by year Varies by Varies by Varies by year Varies by vear vear vear vear Varies by Varies by year Varies by Varies by Varies by year Varies by vear vear vear vear Compass Dir NIA N

SE SSW WNW N

SE s

SW SSW N

SSW WNW N

WNW WSW WNW SSE SSW w

WNW WNW WNW Varies by vear Varies by vear Varies by vear Varies by vear Varies by vear

CY-BY-170-301 Revision 15 Page 185 of 188 LATITUDE/LONGITUDE POSITIONS OF REMP SAMPLES Table 6-2 Dosimeter Locations Note: Dosimeters are also located at each air sampling station Sampling Location Latitude Longitude Distance Distance Direction Sector (deg)

(deg)

(km)

(mi)

(deg)

From Stack nner R" mg BY-101-1 42.07908

-89.28243 0.48 0.30 2

A BY-101-2 42.07912

-89.28188 0.49 0.30 8

A BY-102-1 42.08757

-89.27522 1.56 0.97 23 B

BY-102-2 42.08752

-89.27438 1.58 0.98 26 B

BY-103-1 42.09068

-89.25822 2.69 1.67 49 C

BY-103-2 42.09020

-89.25802 2.67 1.66 50 C

BY-103-3 42.07893

-89.27692 0.67 0.42 45 C

BY-104-1 42.08345

-89.25798 2.26 1.40 65 D

BY-104-2 42.08303

-89.25797 2.24 1.39 66 D

BY-104-3 42.07720

-89.27717 0.53 0.33 59 D

BY-105-1 42.07462

-89.25777 2.06 1.28 59 E

BY-105-2 42.07598

-89.25760 2.08 1.29 90 E

BY-106-1 42.06822

-89.25770 2.19 1.36 109 F

BY-106-2 42.06770

-89.25758 2.22 1.38 111 F

BY-107-1 42.05870

-89.26647 2.23 1.39 143 G

BY-107-2 42.05873

-89.26580 2.26 1.40 142 G

BY-107-3 42.07027

-89.27730 0.66 0.41 138 G

BY-108-1 42.06588

-89.27790 1.06 0.66 158 H

BY-108-2 42.06578

-89.27920 1.03 0.64 164 H

BY-109-1 42.06580

-89.28417 1.00 0.62 187 J

BY-109-2 42.06583

-89.28427 1.00 0.62 188 J

BY-110-1 42.06578

-89.28738 1.07 0.66 201 K

BY-110-2 42.06577

-89.28793 1.08 0.67 204 K

BY-111-3 42.06573

-89.29173 1.25 0.78 217 L

Sector N

N NNE NNE NE NE NE ENE ENE ENE E

E ESE ESE SE SE SE SSE SSE s

s SSW SSW SW

Sampling Location BY-111-4 BY-112-3 BY-112-4 BY-113-1 BY-113-2 BY-114-1 BY-114-2 BY-115-1 BY-115-2 BY-116-1 BY-116-2 BY-116-3 CY-BY-170-301 Revision 15 Page 186 of 188 LATITUDE/LONGITUDE POSITIONS OF REMP SAMPLES Table 6-2 Dosimeter Locations (Continued)

Latitude Longitude Distanc Distance Direction Sector (deg)

(deg) e(km)

(mi)

(deg)

From Stack I

R" nner me 42.06565

-89.29363 1.36 0.85 222 L

42.06967

-89.29660 1.28 0.80 244 M

42.07010

-89.29653 1.26 0.78 246 M

42.07385

-89.29670 1.16 0.72 265 N

42.07432

-89.29662 1.15 0.71 268 N

42.07955

-89.29665 1.27 0.79 295 p

42.08000

-89.29673 1.30 0.81 297 p

42.08433

-89.29705 1.60 0.99 312 Q

42.08473

-89.29702 1.63 1.01 313 Q

42.09185

-89.29697 2.24 1.39 328 R

42.09227

-89.29705 2.28 1.42 329 R

42.08702

-89.28810 1.44 0.89 342 R

Sector SW WSW WSW w

w WNW WNW NW NW NNW NNW NNW

Sampling Location BY-201-3 BY-201-4 BY-202-1 BY-202-2 BY-203-1 BY-203-2 BY-204-1 BY-204-2 BY-205-1 BY-205-2 BY-206-1 BY-206-2 BY-207-1 BY-207-2 BY-208-1 BY-208-2 BY-209-1 BY-209-4 BY-210-3 BY-210-4 BY-211-1 BY-211-4 CY-BY-170-301 Revision 15 Page 187 of 188 LATITUDE/LONGITUDE POSITIONS OF REMP SAMPLES Table 6-2 Dosimeter Locations (Continued)

Latitude (deg)

Longitude Distance Distance Direction Sector (deg)

(km)

(mi)

(deg)

From Stack u er me 0 t R"

42.13811

-89.28378 7.04 4.37 359 A

42.13810

-89.28316 7.04 4.37 360 A

42.13623

-89.25798 7.13 4.43 17 B

42.14157

-89.25817 7.70 4.78 15 B

42.12840

-89.22405 7.69 4.78 39 C

42.12258

-89.21855 7.51 4.67 45 C

42.10407

-89.21380 6.57 4.08 60 D

42.09472

-89.20980 6.43 4.00 70 D

42.08028

-89.20923 6.11 3.80 84 E

42.07587

-89.20907 6.09 3.78 89 E

42.05707

-89.20862 6.44 4.00 108 F

42.04622

-89.20870 6.89 4.28 117 F

42.02793

-89.23200 6.68 4.15 141 G

42.03008

-89.23523 6.32 3.93 142 G

42.02425

-89.24565 6.39 3.97 151 H

42.02340

-89.25740 6.07 3.77 160 H

42.01717

-89.27887 6.40 3.98 177 J

42.01657

-89.27917 6.47 4.02 177 J

42.02180

-89.31012 6.30 3.91 201 K

42.02180

-89.31083 6.32 3.93 202 K

42.02658

-89.35338 7.93 4.93 228 L

42.02645

-89.35278 7.90 4.91 227 L

Sector N

N NNE NNE NE NE ENE ENE E

E ESE ESE SE SE SSE SSE s

s SSW SSW SW SW

Sampling Location BY-212-1 BY-212-4 BY-213-1 BY-213-4 BY-214-1 BY-214-4 BY-215-1 BY-215-4 BY-216-1 BY-216-2 BY-301-1 BY-301-2 BY-309-1 BY-309-2 BY-309-3 BY-309-4 BY-314-2 CY-BY-170-301 Revision 15 Page 188 of 188 LATITUDE/LONGITUDE POSITIONS OF REMP SAMPLES Table 6-2 Dosimeter Locations (Continued)

Latitude Longitude Distance Distance Direction Sector (deg)

(deg)

(km)

(mi)

(deg)

From Stack 0 t R"

u er ID2 42.04847

-89.36643 7.52 4.67 247 M

42.04888

-89.36672 7.52 4.67 248 M

42.07263

-89.37440 7.59 4.72 268 N

42.07183

-89.37440 7.60 4.72 268 N

42.09397

-89.36945 7.49 4.65 287 p

42.09397

-89.36890 7.45 4.63 287 p

42.11618

-89.34107 6.68 4.15 314 Q

42.11710

-89.34100 6.74 4.19 314 Q

42.13058

-89.32910 7.30 4.54 328 R

42.13847

-89.31702 7.63 4.74 338 R

S

. II ipecaa nterest 42.07830

-89.28338 0.40 0.25 352 A

42.07685

-89.28230 0.24 0.15 7

A 42.06995

-89.28268 0.53 0.33 183 J

42.06887

-89.28200 0.65 0.40 175 J

42.06865

-89.28358 0.68 0.42 186 J

42.06850

-89.28472 0.71 0.44 194 K

42.07618

-89.28806 0.48 0.29 290 p

Sector WSW WSW w

w WNW WNW NW NW NNW NNW N

N s

s s

SSW WNW