Attachment I to JPN-96-031 PROPOSED TECHNICAL SPECIFICATION CHANGES (JPTS-96-003) i New York Power Authority JAMES A. FITZPATRICK NUCLEAR POWER PLANT Docket No. 50-333 DPR-59 i

t-e 9606270248 960620 PDR ADOCK 05000333 PDR p

1 JAFNPP TABLE OF CONTENTS (Cont'd) l 6.16 Process Control Program (PCP) 258b 6.17 Offsite Dose Calculation Manual (ODCM) 258b l

6.18 Major Modifications to Radioactive Liquid, Gaseous, and 258c Solid Waste Treatment Systems 6.19 Postaccident Sampling Program 258e 6.20 Primary Containment Leakage Rate Testing Program 258e 1

l 7.0 References 285 l

l l

l l

l f

1 i

Amendment No. 7,22,00,100, I

iv

JAFNPP LIST OF TABLES Table Iltla Eaga 4.2-8 Minimum Test and Calibration Frequency for Accident Monitoring 86 Instrumentation

'4.6-1 Snubber Visual inspection Interval 161 4.6-2 Minimum Test and Calibration Frequency for Drywell Continuous 162a Atmosphere Radioactivity Monitoring System 4.7-1 (DELETED) 210 4.7-2 (DELETED) 211 1

3.12-1 (DELETED) 244a i

3.12-2 (DELETED) 244a 3.12-3 (DELETED) 244a 4.12-1 (DELETED) 244a 4.12-2 (DELETED) 244a 4.12-3 (DELETED) 244a l

6.2-1 Minimum Shift Manning Requirements 260a 6.10-1 Component Cyclic or Transient Limits 261 l

Amendment No. 20,22,02,111,100,104,150,170,180,181,210,218, vi

l l

JAFNPP l

4.0 BASES A.

This specification provides that surveillance activities necessary An example of an exception when the test intervalis not to insure the Limiting Conditions for Operation are met and will specified in the regulations is the Note in Specification 6.20, be performed during the OPERATIONAL CONDITIONS

" Primary Containment Leakage Rate Testing Program," which l

(modes) for which the Limiting Conditions for Operation are states "The provisions of Specification 4.0.B do not apply to the applicable. Provisions for additional surveillance activities to be test frequencies specified in the Primary Containment Leakage performed without regard to the applicable OPERATIONAL Rate Testing Program." This exception is provided because CONDITIONS (modes) are provided in the individual the program already includes provisions for extension of Surveillance Requirements.

intervals.

i I

B.

Specification 4.0.B establishes the limit for which the specified C.

This specification establishes the failure to perform a time interval for Surveillance Requirements may be extended.

Surveillance Requirement within the allowed surveillance it permits an allowable extension of the normal surveillance interval, defined by the provisions of Specification 4.0.B as a interval to facilitate surveillance scheduling and consideration of condition that constitutes a failure to meet the OPERABILITY plant operating conditions that may not be suitable for requirements for a Limiting Condition for Operation. Under the conducting the surveillance (e.g., transient conditions or other provisions of this specification, systems and compont " are ongoing surveillance or maintenance activities). It also assumed to be OPERABLE when Surveillance Requirements provides flexibility to accommodate the length of a fuel cycle for have been satisfactorily performed within the specified time surveillances that are performed at each refueling outage and interval. However, nothing in this provision is to be construed are specified with a 24 month surveillance interval. It is not as implying that systems or components are OPERABLE when intended that this provision be used repeatedly as a they are found or known to be inoperable although still meeting convenience to extend surveillance intervals beyond that the Surveillance Requirements. This specification also clarifies 1

specified for surveillances that are not performed during that the ACT!ON requirements are applicable when refueling outages. The limitation of this specification is based Surveillance Requirements have not been completed within the on engineering judgement and the recognition that the most allowed surveillance interval and that the time limits of the probable result of any particular surveillance being performed is ACTION requirements apply from the point in time it is the verification of conformance with the Surveillance identified that a surveillance has not been performed and not at Requirements. The limit on extension of the normal the time that the allowed surveillanc ; was exceeded.

surveillance interval ensures that the reliability confirmed by Completion of the Surveillance Requirement within the surveillance activities is not significantly reduced below that allowable outage time limits of the ACTION requirements obtained from the specified surveillance interval The restores compliance with the requirements of Specification exceptions to Specification 4.0.B are those surveillances for 4.0.C. However, this does not negate the fact that the failure which the 25% extension of the interval specified does not to have performed the surveillance within the allowed apply. These exceptions are stated in the individual Technical-surveillance interval, defined by the provisions of Specification t

Specifications. The requirements of regulations take 4.0.B, was a violation of the OPERABILITY requirements of a precedence over the Technical Specifications. Therefore, Limiting Condition for Operation that is subject to enforcement I

when a test interval is specified in the regulations, the test action. Further, the failure to interval cannot be extended under the provisions of 4.0.B, and the surveillance requirement will be identified as an exception.

f Amendment No.

me, mm, 30e

JAFNPP 4.0 BASES - Continued C.

Continued C.

Continued perform a surveillance within the provisions of Specification Surveillance Requirements do not have to be performed on

(

4.0.B is a violation of a Technical Specification requirement inoperable equipment because the ACTION requirements and is, therefore, a reportable event under the requirements of define the remedial measures that apply. However, the 10 CFR 50.73(a)(2)(i)(B) because it is a condition prohibited by Surveillance Requirements have to be met to demonstrate that the plant Technical Specifications.

inoperable equipment has been restored to OPERABLE status.

If the allowable outage time limits of the ACTION requirements are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or a shutdown is required to comply D.

This specification establishes the requirement that all with ACTION requirements, a 24-hour allowance is provided to applicable surveillances must be met before entry into an permit a delay in implementing the ACTION requirements.

OPERATIONAL CONDITION or other condition of operation

{

This provides an adequate time limit to complete Surveillance specified in the Applicability statement. The purpose of this Requirements that have not been performed. The purpose of specification is to ensure that system and component this allowance is to permit the completion of a surveillance OPERABILITY requirements or parameter limits are met before before a shutdown is required to comply with ACTION entry into an OPERATIONAL CONDITION or other specified requirements or before other remedial measures would be condition associated with plant shutdown as well as startup.

required that may preclude completion of a surveillance. The basis for this allowance includes consideration for plant Under the provisions of this specification, the applicable conditions, adequate planning, availability of personnel, the Surveillance Requirements must be performed within the time required to perform the surveillance and the safety specified surveillance interval to ensure that the Limiting significance of the delay in completing the required Conditions for Operation are met during initial plant startup or surveillance. This provision also provides a time limit for the following a plant outage.

completion of Surveillance Requirements that become applicable as a consequence of OPERATIONAL CONDITION When a shutdown is required to comply with ACTION (mode) changes imposed by ACTION requirements and for requirements, the provisions of this specification do not apply completing Surveillance Requirements that are applicable when because this would delay placing the facility in a lower an exception to the requirements of Specification 4.0.C is CONDITION of operation.

allowed. If a surveillance is not completed within the 24-hour allowance, the time limits of the ACTION requirements are applicable at that time. When a surveillance is performed within the 24-hour allowance and the Surveillance Requirements are not met, the time limits of the ACTION requirements are applicable at the time the surveillance is terminated.

Amendment No. 40, S4, SS,100,162,133,227, 30f I

JAFNPP 3.7 (cont'd) 4.7 (cont'd)

(2)

During testing which adds heat to the suppression pool, the water temperature shall not exceed 10 F above the normal power operation limit specified in (1) above. In connection with such testing, the pool temperature must be reduced to below the normal power operation limit specified in (1) above within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

(3)

The reactor shall be scrammed from any operating condition if the pool temperature reaches 110 F. Power operation shall not be resumed until the pool temperature is reduced below the normal power operation limit specified in (1) above.

(4)

During reactor isolation conditions, the reactor pressure vessel shall be depressurized to less than 200 psig at normal cooldown rates if the pool temperature reaches 120 F.

2.

Primary containment integrity shall be maintained at all times when the reactor is critical or when the reactor water 2.

a.

. Perform required visual examination and leakage rate temperature is above 212 F, and fuel is in the reactor vessel, testing of the Primary Containment in accordance with except while performing low power physics tests at the Primary Containment Leakage Rate Testing atmospheric pressure at power levels not to exceed 5 MWt.

Program.

b.

Demonstrate leakage rate through each MSIV is s 11.5 scfh when tested at 2 25 psig. The testing frequency is in accordance with the Primary Containment Leakage Rate Testing Program.

c.

Once per 24 months, demonstrate the leakage rate of 10AOV-68A,B for the Low Pressure Coolant injection system and 14AOV-13A,B for the Core Spray system to be less than 11 scfm per valve when pneumatically tested at 2-45 psig at ambient temperature, or less than 10 gpm per valve if hydrostatically tested at z 1000 psig at ambient temperature.

t Amendment No. M, 166

de tele D

nee B

)g ev a

3 P

H g

P N

5 7

g F

7 6

g 1

1 a

A J

h p

g t

u xe o

N r

h

(

t 76 1

sega P

.o N

tne m

dne m

A llll l

JAFNPP t

4.7 BASES (cont'd) assumption of no holdup in the secondary containment, 3.

The MSIVs are tested at a pressure less than P, and resulting in a direct release of fission products from the 2 25 psig, with a leakage rate acceptance criteria of primary containment through the filters and stack to the s 11.5 scfh per valve. This exemption was approved environs. Therefore, the specified primary containment leak by the NRC in the original Technical Specifications rate and filter efficiency are conservative and provide (Table 4.7-2).

additional margin between expected offsite doses and 10CFR100 guidelines.

The Program as implemented meets the requirements of Option B of 10 CFR 50 Appendix J (16) and Regulatory The leakage rate testing program was originally based on Guide 1.163 (13), with the exception stated in Specification NRC guidelines for development of leak rate testing and 6.20. This exception applies to valves currently installed in surveillance schedules for reactor containment vessels.

this configuration, and does not apply to new installations.

Containment structural integrity is currently verified with This exception is consistent with TS Table 4.7-2, previously visual inspections and containment leak tightness is verified contained in the TS, which allows reverse direction testing of by the leakage rate surveillance testing described in the valves as an exception to the requirements of the draft JAFNPP Primaiy Containment Leakage Rate Testing Appendix J, on the basis that pressurization direction was Progre.m.

not a requirement at the time of plant design.

The following are the exemptions to 10 CFR 50 Appendix J, Option A, that have been approved by the NRC, and remain applicable to Option B of 10 CFR 50, Appendix J:

1.

The Type C exceptions listed on Table 4.7-2,

" Exception to Type C Test', as of the date of B.

Standbv Gas Treatment System and issuance of Amendment 194 (July 29,1993).

C.

Secondary Containment 2.

Valves which are sealed with fluid from a seal Initiating reactor building isolation and operation of the system, such as the liquid in the suppression Standby Gas Treatment System to maintain at least a 1/4 in.

chamber are not required to be Type C tested. This of water vacuum within the secondary containment provides exemption was approved by the NRC in the original an adequate test of the operation of the reactor Technical Specifications (SR 4.7.A.2.c(3)).

Amendment No.97-184, 194

JAFNPP Pages 198 through 213 Have Been Deleted Amendment No. 40,01,110,150,170, 198 (Next page is 214)

JAFNPP 6.19 POSTACCIDENT SAMP.LlNG PROGRAM A program shall be established, implemented, and maintained which will ensure the capability to obtain and analyze reactor coolant, radioactive iodines and particulates in plant gaseous effluents, and containment atmosphere samples under accident conditions. The program shallinclude the following:

A) Training of personnel,

8) Procedures for sampling and analysis, C) Provisions for maintenance of sampling and analysis 6.20 PRIMARY CONTAINMENT LEAKAGE RATE TESTING PROGRAM i

A program shall be established to implement the leakage rate testing of the Primary Containment as required by 10 CFR 50.54 (o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the l

guidelines contained in Regulatory Guide 1.163, " Performance-Based Containment Leak-Test Program", dated September 1995, as modified by the exception that Type C l

testing of valves not isolable from the containment free air space may be accomplished by pressurization in the reverse direction provided that testing in this manner provides equivalent or more conservative results than testing in the accident direction. If potential atmospheric leakage paths (e.g., valve stem packing) are not subjected to test pressure, the portions of the valve not exposed to test pressure shall bo subjected to leakage rate measurement during regularly scheduled Type A testing. A list of these valves, the leakage rate measurement method, and the acceptance criteria, shall be contained in the Program.

A.

The peak Primary Containment internal pressure for the design basis loss of coolant accident (P ), is 45 psig.

B.

The maximum allowable Primary Containment leakage rate (L ), at P., shall be 0.5% of primary containment air weight per day.

C.

The leakage rate acceptance criteria are:

1.

Primary containment leakage rate acceptance criteria is s 1.0 L.,

During unit startup following testing in accordance with this program, the leakage rate acceptance enteria are s 0.60 L, for the Type B and Type C tests and s 0.75 L, for the Type A tests; 2.

Airlock testing acceptance criteria are:

a.

Overall airlock leakage rate is s 0.05 L, when tested at 2 P.,

b.

For each door seal, laakage rate is s 120 scfd when tested at a l

P,.

3.

MSIV leakage rate acceptance criteria is s 11.5 scfh for each MSIV when tested at 2 25 psig.

D.

The provisions of Specification 4.0.B do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program.

l E.

The provisions of Specification 4.0.C are applicable to the Primary Containment Leakage Rate Testing Program I

t

?

Amendment No. 400, 258e

JAFNPP

7.0 REFERENCES

(1)

E. Janssen, " Multi-Rod Burnout at Low Pressure," ASME Paper (9)

C.H. Robbins, " Tests of a Full Scale 1/48 Segment of the 62-HT-26, August 1962.

Humbolt Bay Pressure Suppression Containment," GEAP-3596, November 17,1960.

(2)

K.M. Backer, " Burnout Conditions for Flow of Boiling Water in Vertical Rod Clusters," AE-74 (Stockholm, Sweden), May 1962.

(10) " Nuclear Safety Program Annual Progress Report for Period Ending December 31,1966, Progress Report for Period Ending (3)

FSAR Section 11.2.2.

December 31,1966, ORNL-4071."

(4)

FSAR Section 4.4.3.

(11) Section 5.2 of the FSAR.

(5) 1.M. Jacobs, " Reliability of Engineered Safety Features as a (12) TID 20583, "Lealage Characteristics of Steel Containment Function of Testing Frequency," Nuclear Safety, Vol 9, No. 4, Vessel and the Analysis of Leakage Rate Determinations."

July-August 1968, pp 310-312.

(13) Regulatory Guide 1.163, " Performance-Based Containment Leak-(6)

Deleted Test Program", dated September 1995.

(7) 1.M. Jacobs and P.W. Mariott, APED Guidelines for Determining (14) Section 14.6 of the FSAR.

Safe Test Intervals and Repair Times for Engineered Safeguards

- April 1969.

(15) ASME Boiler and Pressure Vessel Code, Nuclear Vessels, Section 111. Maximum allowable internal pressure is 62 psig.

(8)

Bodega Bay Preliminary Hazards Report, Appendix 1, Docket 50-205, December 28,1962.

(16) 10 CFR Part 50, Appendix J, " Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors, Option B -

Performance Based Requirements", Effective Date October 26, 1995 (17) Deleted Amendment No. 100,227, 285

. =.

l Attachment ll to JPN-96-031 REVISED SAFETY EVALUATION FOR l

P_BOPOSED TECHNICAL SPECIFlCATION_ CHANGES _QPTS-96-003)

(Changes are identified by revision bars located in the right margin) l l

New York Power Authority l

JAMES A. FITZPATRICK NUCLEAR POWER PLANT l

Docket No. 50-333 DPR-59 l

l l

I Attachment il to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 1 of 18 1.

DESCBlPTION QF THE PROPOSEDIBANGES These proposed Technical Specification (TS) changes support adoption of the primary containment leakage rate testing requirements of Option B to 10 CFR 50, Appendix J (Option B). The specific changes are as follows:

1.

Page iv, Table of Contents, add 6.20, " Primary Containment Leakage Rate Testing Program" and "page 258e" to the Table of Contents.

2.

Page vi, List of Tables, denote that Table 4.7-2, " Exception to Type C Tests," is deleted. The revised text reads:

"4.7-2 (DELETED) 211" 3.

Bases 4.0.B, page 30e, insert the following after the current discussion *

"The exceptions to Specification 4.0.B are those sunteillances for which the 25%

extension of the interval specified does not apply. These exceptions are stated in the individual Technical Specifications. The requirements of regulations take precedence over the Technical Specifications. Therefore, when a test interval is specified in the regulations, the test interval cannot be extended under the provisions of 4.0.B, and the surveillance requirement will be identified as an exception. An example of an exception when the test interval is not specified in the regulations Is the Note in Specification 6.20, " Primary Containment Leakage Rate Testing Program," which states "The provisions of Specification 4.0.B do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program." This exception is provided because the program already includes provisions for extension of intentals."

Note: This change results in the last five lines of the second column being moved to Page 30f.

4.

Pages 166 through 174, delete the following SRs:

4.7.A.2.a (1) through (10),

4.7.A.2.b (1), (2) 4.7.A.2.c (1) through (5),

4.7.A.2.e (1) through (6),

4.7.A.2.f.

l l

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 2 of 18 5.

Page 166, insert the following new SRs:

"4.7.A.2.a Perform required visual examination and leakage rate testing of the Primary Containment in accordance with the Primary Containment Leakage Rate Testing Program."

4.7.A.2.b Demonstrate leakage rate through each MSIV is s 11.5 scfh when tested at 2 25 psig. The testing frequency is in accordance with the Primary Containment Leakage Rate Testing Program.

6.

Page 167, add note stating that pages 167 through 175 have been deleted. Add note under the page number stating "(Next Page is 176)."

7.

Page 172, relocate SR 4.7.A.2.d (1) to page 166 and renumber as SR 4.7.A.2.c. Make editorial changes to improve readability. The revised SR reads:

"4.7.A.2.c Once per 24 months, demonstrate the leakage rate of valves 10AOV-68A,8 for the Low Pressure Coolant Injection system and 14AOV-13A,B for the Core Spray system to be less than 11 scfm per valve when pneumatically tested at a 45 psig at ambient temperature, or less than 10 gpm per valve if hydrostatically tested at 21000 psig at ambient temperature."

8.

Page 174, delete asterisked notes for one-time exemptions from the Type A,8 and C testing requirements of 10 CFR 50 Appendix J.

9.

Page 175, delete the intentionally blank page.

10.

Bases 4.7.A, Page 194, delete the primary containment leakage rate testing discussion which starts on the first column, second paragraph. Replace with "The leakage rate testing program was originally based on NRC guidelines for development of leak rate testing and surveillance schedules for reactor containment vesseis. Containment structural integrity is currently verified with visual inspections and containtnent leak tightness is verified by the leakage rate surveillance testing described in the JAFNPP Primary Containment Leakage Rate Testing Program.

!l

. 1 to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 3 of 18 The following are the exemptions to 10 CFR 50 Appendix J, Option A, that have been approved by the NRC, and remain applicable to Option B of 10 CFR 50, Appendix J:

1.

The Type C exceptions listed on Table 4.7-2, " Exception to Type C Tests," as of the date of issuance of Amendment 194 (July 29,1993).

2.

Valves which are sealed with fluid from a seal system, such as the liquid in the suppression chamber are not required to be Type C tested. This exemption was approved by the NRC in the original Technical Specifications (SR 4.7. A.2.c(3)).

3.

The MSIVs are tested at a pressure less than P, and > 25 psig, with a leakage rate acceptance criteria of s 11.5 scfh per valve. This exemption was approved

{

by the NRC in the original Technical Specifications (Table 4.7-2).

The Program as implemented meets the requirements of Option B of 10 CFR 50 Appendix J (16) and Regulatory Guide 1.163 (13), with the exception stated in Specification 6.20. This exception applies to valves currently installed in this configuration, and does not apply to new installations. This exception is consistent with TS Table 4.7-2, previously contained in the TS, which allows reverse direction testing of valves as an exception to the requirements of the draft Appendix J, on the basis that pressurization direction was not a requirement at the time of plant design."

11.

Page 198, Change page "209" to page "213," and change next page from "210" to "214" to reflect the deletion of page 211 through 213b discussed in item 13.

12.

Page 210, Delete the Intentionally blank page.

13.

Page 211 through 213b, Table 4.7-2 " Exception to Type C Tests," delete pages and relocate Table in its entirety to the Containment Leakage Rate Testing Program.

l l

1 l

1 Attachment ll to JPN-96-031 l

SAFETY EVALUATION - REVISION 2 l

Page 4 of 18 14.

Page 258e, Administrative Controls, add new section 6.20 entitled " Primary Containment Leakage Rate 1esting Program." The new section reads:

"6.20 Primarv Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the Primary l

Containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, " Performance-Based Containment Leak-Test Program," dated September 1995, as modified by the exception that Type C testing of valves not isolable from the containment free air space may be accomplished by pressurization in the reverse direction provided that testing in this manner provides equivalent or more conservative results than testing in the accident direction. If potential atmospheric leakage paths (e.g., valve stem packing) are not subjected to test pressure, the portions of the valve not exposed to test pressure shall be subjected to leakage rate measurement during regularly scheduled Type A testing. A list of these valves, the leakage rate measurement method, and the acceptance criteria, shall be contained in the Progrcrn.

A.

The peak Primary Containment internal pressure for the design basis loss of coolant accident (P ), is 45 psig.

B.

The maximum allowable Primary Containment leakage rate (L.), at P, shall be 0.5% of primary containment air weight per day.

I C.

The leakage rate acceptance criteria are:

1.

Primary containment leakage rate acceptance criteria is s 1.0 L,.

During unit startup following testing in accordance with this program, the leakage rate acceptance criteria are s 0.60 L, for the Type B and Type C tests and s 0.75 L, for the Type A test; 2.

Airlock testing acceptance criteria are:

a.

Overall airlock leakage rate is s 0.05 L, when tested at 2 P.,

b.

For each door seal, leakage rate is s 120 SCFD when pressurized to 2 P,.

3.

MSIV leakage rate acceptance criteria is s 11.5 scfh for each MSIV j

when tested at 2 25 psig f

l Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 5 of 18 D.

The provisions of Specification 4.0.B do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program.

E.

The nrovisions of Specification 4.0.C are applicable to the Primary Containment Leakage Rate Testing Program."

15.

Page 285, delete Reference 13 as it no longer applies under Option B, and replace with reference to Regulatory Guide 1.163. The revised Reference 13 reads:

"(13) Regulatory Guide 1.163, " Performance-Based Containment Leak-Test Program," dated September 1995."

16.

Page 285, revise Reference 16 to reflect ne v revisions to 10 CFR 50 Appendix J. The revised reference reads:

"(16) 10 CFR Part 50 Appendix J, " Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors, Option B-Performance Based Requirements," Effective date October 26,1995.

17.

Page 285, delete Reference 17 as it no longer applies under Option B, and replace with " Deleted."

ll.

EURPOSE OF THE PROPOSED CHANGES The proposed changes to the TS support adoption of the primary containment leakage rate testing requirements of Option B at the FitzPatrick plant.

I The original FitzPatrick TS were written prior to the effective date of the 10 CFR 50 Appendix J regulation. Therefore, to ensure adequate primary containment leak rate testing, many of the requirements of the draft Appendix J requirements were incorporated directly into the Specifications. Exceptions were included as part of the initial issuance of the TS. Consequently, primary containment leak rate testing requirements duplicate those contained in the draft Appendix J (Option A), with approved exemptions.

To simplify implementation of Option B, and prevent conflicts with the TS currently based on Option A, the Authority proposes to delete the following SRs:

' 4.7.A.2.a(1) through (10)

Type A testing requirements - Option A Section Ill.A.

4.7.A.2.b(1) and (2)

Type B testing requirements - Option A Section til.B.

4.7.A.2.c(1), (2)

Type C testing requirements - Option A Section Ill.C

l 1

Attachment ll to JPN-96-031 l

SAFETY EVALUATION - REVISION 2 Page 6 of 18 4.7.A.2.c(3)

Approved exemption that eliminates Type C testing for valves that are sealed from a seal system, such as the water in the suppression chamber. This exemption is l

retained and relocated to the Program.

4.7. A.2.c.4 Reference to Table 4.7-2, " Exception to Type C tests."

i l

The Table is relocated to the Program.

4.7. A.2.e(1), (2)

Periodic retest schedule requirements - Option A Section Ill.D 4.7.A.2.e(3) through (4)

Requirements for Type B tests of airlocks and testing of airlock seals. These SRs were exemptions from Option A l

testing requirements that are no longer required for implementation of Option B. Acceptance criteria is relocated to prok 3ed Specification 6.20.

4.7.A.2.e(5)

Type C retest schedule - Option A Section Ill.D.

4.7.A.2.f Containment modification requirements - Option A Section IV.A The Authority proposes to relocate Table 4.7-2, " Exception to Type C Tests," from the TS to the Program. This table lists the approved exemptions to Appendix J for Type C tests at the FitzPatrick Plant, and is still applicable to Option B.

The above SRs and Table are replaced by: (1) New SR 4.7.A.2 (a) which requires visual examination and leak rate testing of the Primary Containment in accordance with the Program; and (2) New SR 4.7.A.2 (b) which incorporates an existing exemption for Type C testing of Main Steam isolation Valves (MSIV) directiv into the TS for consistency with References 2 and 3.

A description of the Program, including plant specific leakage limits, is contained in new Specification 6.20. Regulatory Guide 1.163 (Reference 1) is incorporated, by reference, into new Specification 6.20 as required by Option B, Paragraph V.B.1.

Implementation of Option B requirements will be controlled under the Primary Containment Leakage Rate Testing Program (the Program), in accordance with the requirements of Option B, Regulatory Guide 1.163 (Reference 1), and exemptions from Option A currently approved by the NRC for the FitzPatrick plant. The proposed TS changes are consistent with guidelines provided in NUREG-1433 (Reference 2) and NRC letter dated November 2,1995 (Reference 3), to the extent practicable.

There are differences between the FitzPatrick TS and Reference 2 relating to Containment Systems that will be resolved in our upcoming Improved Standard Technical Specifications conversion effort. These differences do not adversely affect the TS changes required to support implementation of Option B at the FitzPatrick plant.

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2

]

Page 7 of 18 111.

SAFETY IMPLLCATIONS OF THE_PEOPOSED CHANGES This section discusses the safety implications of the TS changes relating to iniplementation of Option B at the FitzPatrick Plant and the clarification of the L, numerical definition.

1.

Option B Implementation The testing requirements of 10 CFR 50, Appendix J, ensure that leakage through the primary containment, including systems and components that penetrate the primary containment, does not exceed the allowable leakage rate values specified in the TS and bases. This ensures that an adequate primary containment boundary is maintained during and after an accident, thereby assuring that the p mary containment p

function assumed in the safety analyses is maintained.

A revision to 10 CFR 50, Appendix J, to allow a performance-based approach to containment leakage rate testing became effective on October 26,1995. The revision added Option B " Performance Based Requirements" to Appendix J to allow licensees to voluntarily replace the prescriptive testing requirements of Appendix J with testing requirements based on both overall and individual component leakage rate performance. Option B allows plants with satisfactory Integrated Leak Rate Testing (ILRT) performance history to reduce the Type A testing frequency from three tests in ten years to one test in ten years. For Type B and Type C tests, the testing frequency can be reduced based on the leak rate test history of each component. The Authority has elected to perform Type A, Type B and Type C containment leak rate testing on a performance basis.

Regulatory Guide 1.163 (Reference 1) was issued by the NRC Staff as an acceptable method for implementing Option B. It states that NEl 94-01 (Reference 4) provides methods acceptable to the NRC staff for complying with Option B, with the four exceptions listed in Section C of thn Regulatory Guide. The Authority will comply with the methods outlined in the Regulatory Guide, with the exception of Type C testing of containment isolation valves in the reverse (non-accident) direction identified in l

proposed Specification 6.20.

The adoption of a performance-based primary containment leakage rate testing l

program does not change the method by which leakage rate testing is performed. The tests will continue to be performed at full pressure (P,) or greater, with the exception of l

existing NRC approved exemptions. Plant specific limits for allowable leakage rates (L.) and required test pressure (P ) are retained in the proposed TS and are not changed as a result of adopting Option B testing requirements. Testing methods will continue to be in accordance with existing leak rate testing requirements, as modified by exemptions previously approved by the NRC.

i

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 8 of 18 These changes do not alter the plant design, only the frequency of measuring primary containment leakage. Therefore, the proposed changes do not directly result in an increase in containment leakage. However, decreasing the test frequency can increase the probability that a large increase in containment leakage could go undetected for an extended period of time. NUREG-1493, " Performance-Based Containment Leak-Test Program, Final Report," (Reference 7) made the following observations with regard to the decreased test frequency:

Reducing the Type A (ILRT) testing frequency from the current three per ten

=

years to one per 20 years was found to lead to an imperceptible increase in risk. The estimated increase in risk is small because ILRTs identify only a few potential leakage paths that can not be identified by Type B and Type C testing, and the leaks that have been found by Type A tests have only been marginally above existing requirements. Given the insensitivity of risk to containment leakage rate, and the small fraction of leakage detected solely by Type A testing, increasing the interval between ILRT testing has minimal impact on l

public risk.

While Type B and C tests identify the vast majority (greater than 95 percent) of

=

all potential leakage paths, performance-based attematives to current local leakage testing requirements are feasible without significant risk impacts. The risk model used in NUREG-1493 suggests that the number of components tested would be reduced by about 60 percent with less than a three-fold increase in the incremental risk due to containment leakage. Since under existing requirements leakage contributes less than 0.1 percent of overall accident risk, the overall impact is very small.

l Option B states that specific exemptions to Option A of Appendix J, that have been l

formally approved by the NRC or AEC, are still applicable to Option B if necessary, i

unless specifically revoked by the NRC. The following exemptions to Option A will be retained in the Option B Program:

1.

The Type C exceptions listed on Table 4.7-2, " Exception to Type C Tests," as of the date of issuance of Amendment 194 (July 29,1993).

l 2.

Valves which are sealed with fluid from a seal system, such as the liquid in the l

j suppression chamber are not required to be Type C tested. This exemption was approved by the NRC in the original Technical Specifications (SR 4.7.A.2.c(3)).

Attachment Il to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 9 of 18 3.

The MSIVs are tested at a pressure less than P, and ;> 25 psig, with a leakage rate acceptance criteria of s 11.5 scfh. This exemption was approved by the NRC in the original Technical Specifications (Table 4.7-2).

These exemptions focus on the testing methodology aspects of Appendix J and are unaffected by the adoption of Option B testing frequency requirements. A list of approved exemptions will be contained in the Bases of the FuPatrick TS, Section 4.7.A. The details of these exemptions will be contained in the Program.

Changes to the Program will be controlled in accordance with the requirements of 10 CFR 50.59, " Changes, tests and experiments." Thus, a determination of whether Program changes require prior NRC approval will be performed. In addition,10 CFR 50 Appendix J Option B requires Licensee compliance with containment leakage rate testing requirements as stated in the regulation, and included by reference in the proposed TS. Changes to the Program that conflict with the requirements of Option B, or documents referenced in Specification 6.20, require prior NRC approval. The combination of the 10 CFR 50.59 change process and the NRC approval process assure proper control of changes to the Primary Containment Leakage Rate Testing Program.

Current SR 4.7.A.2.d (1) requires pneumatic or hydrostatic leakage rate testing of the LPCI and Core Spray injection testable check valves. These valves are pressure isolation valves that separate the high pressure reactor coolant system from the low pressure LPCI and Core Spray systems. The leakage test required by SR 4.7.A.2.d (1) is not a requirement of 10 CFR 50 Appendix J, therefore, it is not relocated from the TS. Editorial changes to improved readability are made to the SR, and it is moved to page 166 and renumbered as SR 4.7.A.2.c.

Based on the above discussion, removal of the containment leakage rate testing details, except for plant specific limits, from the TS is acceptable. The proposed TS and the Program comply with Regulatory Guide 1.163 (Reference 1) requirements, with the exception of reverse direction Type C testing of valves described in Section Ill.3 of this safety evaluation, and contain sufficient controls to ensure that the primary containment structural Integrity is inspected and maintained, and that leakage is limited to values assumed in the plant safety analyses. Required surveillances will continue to be performed in accordance with TS, written procedures, and instructions auditable by the NRC. Primary containment leakage rate requirements continue to remain an integral part of FitzPatrick plant operation. The changes to current SR 4.7.A.2.d.(1) are editorialin nature and do not change any TS requirement.

2.

DELETED i

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 10 of 18 3.

Exception Regarding Reverse Direction Testing of 17 Primary Containment Isolati D D

Valves Periodic Type C testing in the reverse (non-accident) direction for 17 primary t

containment isolation valves does not expose potential atmospheric leakage paths (e.g., valve stem packing) to test pressure. Therefore, it can not be quantitatively shown that Type C test results are not affected in a non-conservative manner by directionality. Section 8.0 of Reference 4 requires that potential leakage paths to atmosphere be quantitatively determined. Reverse direction testing of these valves is required due the inability to isolate the valves from the containment and the lack of test connections. These valves are reverse direction tested in accordance with the FitzPatrick TS Table 4.7-2, " Exception to Type C Tests."

The affected valves are listed in Table 1 of this safety evaluation. Type C testing in the reverse direction for these valves provides equivalent or more conservative results than testing in the accident direction, with respect to seat leakage. With respect to the globe valves, the test pressurization is under the seat, which tends to unseat the valve.

With respect to the butterfly valves, measured leakage is independent of the direction of test pressure from both a force exerted and seating surface standpoint.

Modifications have been considered that would allow testing in the accident direction or allow potential leakage to atmosphere to be quantitatively determined. The addition of block valves and test connections to allow accident direction testing would increase design complexity, provide additional potential leakage pathways, and increase loading

'on piping penetrating primary containment. Valve stem packing modifications to allow potential leakage to be quantitatively determined would increase design complexity, and provide additional potential leakage pathways. For these reasons, compliance with Reference 1 would incur an undue cost without a commensurate improvement in safety.

There are no safety implications associated with these changes because:

1.

Testing of these 17 valves (Listed in Table 1) during the 1995 Integrated Leakage Rate Test (ILRT) verified that the packing glands were insignificant contributors to the overall integrated leakage rate. The 1995 as-left ILRT leakage rate was 0.0629% weight / day, which was well below the curres.! TS acceptance criteria of 0.5% weight / day.

l l

i

. _ =. _

Attachment Il to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 11 of 18 2.

Adding the results of the 1995 As-Left Type A, B, and C tests together (approximately 2188 SCFD) results in a leakage total well below 0.6Lo (3216 SCFD). This very conservatively shows that significant margin exists to exceeding TS or Appendix J limits.

l 3.

Review of past ILRT results indicates that the 17 valves have not been the cause of an ILRT failure. Based on a review of the maintenance history for each valve, recurring packing or body to bonnet leaks are not expected.

4.

The valve stem packing and body to bonnet gaskets are resilient materials designed to conform to sealing surfaces. The valves are installed in systems which are not normally subjected to design flows, temperatures, or pressures.

During normal operation, the valve stem packing and body to bonnet gaskets are exposed to the primary containment atmosphere, which has a low oxygen content. Based on this, the degradation of the valve stem packing or body to bonnet gaskets due to continuous exposure to a harsh environment is not a concem.

5.

From a risk perspective evaluation, the elimination of modifications that would allow testing in the accident direction or allow potential leakage to atmosphere to be quantitatively determined, can be justified using the technical bases provided for NUREG-1493 (Reference 7). Past studies show that overall l

reactor accident risks are not sensitive to variations in containment leakage rate. This is because reactor accident risks are dominated by accident j

scenarios in which the containment fails or is bypassed. Such scenarios, even 1

though they are of very low probability, dominate the predicted accident risks due to their high consequences. FitzPatrick Individual Plant Examination (IPE) results are consistent with these past technical studies (See Table 2).

Certain NRC sponsored studies (References 8 and 9) indicate that overall plant risk is not sensitive to changes in containment leak rates. From Table 3 the incremental risk from leakage in the range of 1% to 10% per day is small.

FitzPatrick and Peach Bottom are both BWR 4 plants with MARK I containments. Similar results are expected for FitzPatrick.

l 1

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 l

l Page 12 of 18 The analysis described above provides justification that potential leakage paths to atmosphere for these 17 valves is inconsequential. The Authority proposes that a soap bubble test be performed on the pressurized stem / bonnet boundaries of the 17 valves during regular 1y scheduled Type A testing. To provide a direct indication of the leak-tightness of the packing and body to bonnet, the Authority will use the acceptance criteria of zero bubbles for this test. Type C tasting will be performed, as a post work test, following work activities that affect the potential atmospheric leakage paths on any of the 17 valves. A soap bubble test will then be performed on the subject valve (s) at regularly scheduled Type A test intervals. These requirements will be contained in the Program.

IV. EVALUATION OF SIGNIFICANT HAZA_flDS CONSIDERATION The Authority has evaluated the proposed TS Amendment and determined that it does not represent a significant hazards consideration. Based on the criteria for defining a significant hazards consideration established in 10 CFR 50.92, operation of the James A. FitzPatrick Nuclear Power Plant in accordance with the proposed amendment will not:

l 1)

Involve a significant increase in the probability or consequences of an accident previously evaluated because:

J The proposed changes do not involve a change to the design or operation of the plant.

The systems affected by this proposed TS change are not assumed in any safety analyses to initiate any accident sequence. Therefore, the probability of any accident previously evaluated is not increased by this proposed TS change. The proposed TS I

changes maintain an equivalent level of reliability and availability for all affected systems. The ability of the affected systems associated with maintaining leak rate integrity to perform their intended function is unaffected by the proposed TS changes.

i implementation of these changes will provide continued assurance that specified parameters associated with containment integrity will remain within acceptance limits, and as such, will not significantly increase the consequences of a previously evaluated accident.

l l

l l

l

\\

- 1 to JPN-96-031 l

SAFETY EVALUATION - REVISION 2 Page 13 of 18 2)

Create the possibility of a new or different kind of accident from any accident previously evaluated because:

The proposed changes allow adoption of those requirements specified in Option B to 10 CFR 50, Appendix J, and do not involve a change to the plant design and operation. As a result, the proposed changes do not affect the parameters or conditions that could contribute to the initiation of any accidents. The methods of pedorming primary containment leakage rate testing are not changed. No new accident modes are created by allowing extended intervals for Type A, B and C testing. No safety-related equipment or safety functions are altered, or adversely I

affected, as a result of these changes. The proposed changes will not introduce failure mechanisms beyond those already considered in the current plant safety analyses.

Extension of the test intervals does not contribute to the possibility of a new or different I

kind of accident or malfunction from those previously analyzed.

3)

Involve a significant reduction in the margin of safety because:

The proposed changes affect the frequency of primary containment leakage rate testing. The design of the FitzPatrick plant is not changed. The methodology for test I

performance is unchanged and Type A, B and C tests will continue to be performed at a P,. The proposed changes provide sufficient controls to ensure that proper maintenance and repairs are performed on the primary containment, and systems and components penetrating the primary containment. The reliability of containment systems assumed to operate in the plant safety analyses is not reduced. Therefore, the proposed changes provide continued assurance of the leak tightness of the I

containment without adversely affecting the public health and safety and, as such, will not involve a significant reduction in the margin of safety.

This proposed amendment does not involve a significant relaxation of the criteria used to establish safety limits, a significant relaxation of the bases for the limiting safety system settings or a significant relaxation of the bases for the limiting conditions for operations.

Therefore, based on the criteria established in 10 CFR 50.92(c), the proposed change does not constitute a significant hazards consideration.

l

Attachment ll to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 14 of 18 V.

IMELEMENTATION OF THE PROPOSED CHANGES This proposed amendment meets the eligibility criteria for categorical exclusion set forth i

in 10 CFR 51.22(c)(9) as follows:

(i) the amendment involves no significant hazards consideration.

As demonstrated in Section IV of this evaluation, the proposed change involves no significant hazards consideration.

(ii) there is no significant change in the types or significant increase in the amounts of any effluents that may be released offsite.

The NRC environmental assessment performed in support of the Option B rulemaking concluded that adoption of a performance-based leak rate testing program will not significantly affect the quality of the human environment. The effectiveness of the leak rate testing program at FitzPatrick will not be decreased; therefore, there will be no significant changes in the types or amounts of any effluents that may be released offsite.

(iii) there is no significant increase in 'ndividual or cumulative occupational radiation exposure.

Implementation of a performance-based containment leak rate testing program is expected to result in a decrease in the occupational exposure on-site for plant personnel. The proposed changes do not result in increased leakage from the containment and, as such, do not result in significant increase in individual and cumulative occupational radiation exposure.

Based on the above, it is concluded that there will be no impact on the environment resulting from the proposed changes and the proposed changes meet the criteria specified in 10 CFR 51.22 for a categorical exclusion from the requirements of 10 CFR 51.21 relative to requiring a specific environmental assessment by the Commission.

Additionally, implementation of the proposed changes will not adversely affect the Fire Protection Program at the FitzPatrick plant.

The Authority requests NRC approval of this proposed amendment prior to August 1, 1996 in order to adopt these changes prior to the upcoming Fall 1996 Refuelirig Outage.

.. =.

. 1 to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 15 of 18 VI.

CONCLUSION Based on the discussions above, the adoption of Option B to 10 CFR 50, Appendix J, requirements into the TS will not decrease the effectiveness of containment leakage rate testing. Operating limitations will continue to be imposed, and required surveillances will continue to be performed in accordance with Technical Specifications, written procedures and instructions auditable by the NRC. The assumptions in the FitzPatnck licensing bases are not invalidated by the proposed Technical Specification changes.

The Plant Operating Review Committee (PORC) and the Safety Review Committee (SRC) have reviewed these proposed changes to the Technical Specifications and have concluded that they do not involve an unreviewed safety question, or a significant hazards consideration, and will not endanger the health and safety of the public.

Vll.

BEEEBENCES 1.

Regulatory Guide 1.163. Performance-Based Containment Leak-Test Program, dated September 1995.

2.

NUREG-1433, Standard Technical Specifications, Revision 1, dated April 1995.

3.

NRC Letter to Mr. David J. Modeen (NEI), Regarding the Industry's Proposed Technical Specifications for Implementing Option B of Appendix J, dated November 2,1995.

4.

NEl 94-01, Industry Guideline for Implementing Performance-Based Option of 10 CFR 50 Appendix J, Rev. O, dated July 26,1995.

5.

DELETED 6.

DELETED 7.

NUREG-1493, Performance-Based Containment Leak-Test Program, Final Report, dated September 1995 8.

NUREG/CR-4330, " Review of Light Water Reactor Regulatory Requirements, Assessment of Selected Regulatory Requirements that may have Marginal importance to Risk - Reactor Containment Leakage Rates - Main Steam isolation Valve Leakage Control Systems - Fuel Design Safety Reviews," Volume 2, dated June 1,1986.

9.

NUREG-1150, " Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants, Final Summary Report," dated December 1,1990.

Attachment Il to JPN-96-031 l

SAFETY EVALUATION - REVISION 2 Page 16 of 18 Table 1 AdditinnaLinfonnation_on_Valven l

l 1.

Valve Number and

Title:

27AOV-112 - DRYWELL PURGE AND INERT l

ISOLATION VALVE

==

Description:==

24", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

2.

Valve Number and

Title:

27AOV-113 - DRYWELL VENT AND PURGE EXHAUST INNER ISOLATION VALVE

==

Description:==

24", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

3.

Valve Number and

Title:

27AOV-101 A - TORUS VACUUM BREAKER VB-6 ISOLATION VALVE

==

Description:==

20", BUTTERFLY VALVE l

Vendor:

FISHER CONTROLS CO.

4.

Valve Number and

Title:

27AOV-101B - TORUS VACUUM BREAKER VB-7 ISOLATION VALVE

==

Description:==

20", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

5.

Valve Number and

Title:

27AOV-117 - TORUS EXHAUST INNER ISOLATION VALVE

==

Description:==

20", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

6.

Valve Number and

Title:

27MOV-117 - TORUS VENT AND PURGE EXHAUST ISOLATION VALVES (27AOV-117 AND 27AOV-118)

INNER BYPASS VALVE l

==

Description:==

3", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

7.

Valve Number and

Title:

27AOV-116-TORUS PURGE AND INERT ISOLATION VALVE

==

Description:==

20", BUTTERFLY VALVE Vendor:

FISHER CONTROLS CO.

8.

Valve Number and

Title:

27AOV-131 A - CAD TRAIN A NITROGFN MAKE-UP ISOLATION VALVE

==

Description:==

1.5", GLOBE VALVE Vendor:

MASONEILAN INTERNATIONAL INC.

4 f

. 1 to JPN-96-031 SAFETY EVALUATION - REVISION 2 Page 17 of 18 Table 1 Addit.ionaunformation on valves (cont'd.)

9.

Valve Number and

Title:

27AOV-131B - CAD TRAIN B NITROGEN MAKE-UP ISOLATION VALVE

==

Description:==

1.5", GLOBE VALVE Vendor:

MASONEILAN INTERNATIONAL INC.

10.

Valve Number and

Title:

10MOV-31 A - RHR A CONTAINMENT SPRAY INBOARD ISOLATION VALVE

==

Description:==

10", GLOBE VALVE Vendor ANCHOR-DARLING IND.

11.

Valve Number and

Title:

10MOV-31B - RHR B CONTAINMENT SPRAY INBOARD ISOLATION VALVE

==

Description:==

10", GLOBE VALVE Vendor:

ANCHOR-DARLING IND.

12.

Valve Number and

Title:

10MOV-38A - RHR A TO TORUS SPRAY ISOLATION VALVE

==

Description:==

4", GLOBE VALVE Vendor:

WILLIAM POWELL CO.

13.

Valve Number and

Title:

10MOV-38B - RHR B TO TORUS SPRAY ISOLATION VALVE

==

Description:==

4", GLOBE VALVE Vendor:

WILLIAM POWELL CO.

14.

Valve Number and

Title:

27AOV-132A - CAD TRAIN A TORUS N;TROGEN MAKE-UP ISOLATION VALVE

==

Description:==

1.5", GLOBE VALVE Vendor:

MASONEILAN INTERNATIONAL INC.

15.

Valve Number and

Title:

27AOV-1328 - CAD TRAIN B TORUS NITROGEN MAKE-UP ISOLATION VALVE

==

Description:==

1.5", GLOBE VALVE i

Vendor:

MASONEILAN INTERNATIONAL INC.

16.

Valve Number and

Title:

16-1 AOV-101 A - DRYWELL PRESSURE SENSING

==

Description:==

3/8", PLUG TYPE GLOBE VALVE Vendor:

COPES-VULCAN INC.

17.

Valve Number and

Title:

16-1 AOV-1028 - TORUS PRESSURE SENSING

==

Description:==

3/8", PLUG TYPE GLOBE VALVE Vendor.

COPES-VULCAN INC.

l l

t 1 to JPN-96-031 i

SAFETY EVALUATION - REVISION 2 Page 18 of 18 l

Table 2 Conditional Containment Failure Probability Given Core Damage' Time / Containment Location Conditional Probability i

Early/Drywell Failure 0.536 Early/Wetwell Failure 0.068 Late /Drywell Failure 0.116 i

Late /Wetwell Failure 0.144 No Failure 0.136 Table 3 Post Core Damage (Level 3) Comparison of Results Population Dose, person-rem / reactor year Peach Bottom Grand Gulf Leak Rate % / day NUREG/

NUREG-NUREG/

NUREG CR-1150 CR-4330 1150 2

4330 0.5 151 28.3 250 5.66 1

151 250 5

153 28.3 254 5.67 10 153 254 50 174 28.4 288 5.81 100 174 288 l

IContainment venting considered as failure.

i 2See Reference 8 i

3 See Reference 9

i l 11 to JPN-96-031 l

MARKUP OF TECHNICAL SPECIFICATION PAGES i

(JPTS-96-003) i 1

l I

l I

l l

t I

New York Power Authority JAMES A. FITZPATRICK NUCLEAR POWER PLANT Docket No. 50-333 DPR-59 e

i

?'

I i

I i

l L

JATNPP TAnf_F 0F CONTENTS (cont'd)

E.Aga 6.16 Process Control Program (PCP) 258b 6.17 Offsite Dose Calculation Manual (ODCM) 258b 6.18 Major Modifications to Radioactive Liquid.

25ac Gaseous, and Solid Weste Treatment Systems 6.19 Postaccident Sampling Program 258e p->

7.0 References 285

\\~ Q,2O fr firrai-0JluiJhw Lea k~ fe-ka k l b' f W

~

i 4

4

-.d

.t

. g y. p >h

JAFNPP LIST OF TABLES I.ilblf!

IIM EE2 4.2 8 Minimum Test and Calibration Frequency for Accident Monitonn9 86 Instrumentation 4.6-1 Sn'ubber Visual Inspection intental 161 4.6-2 Minimum Test and Calibration Frequency for Drywell Continuous 162a Atmosphere Radioactivity Monitonng System 4.7-1 (DELETED) 210 f

[ Exception to Type C

( De LE TED) 4.7-2 211 3.12 1 (DELETED)

2Ma, 3.12 2 (DELETED) 24a 3.12-3 (DELETED) 24a 4.12 1 (DELETED)

Pua 4.12 2 (DELETED) 24a 4.12 3 (DELETED) 24a '

6.2-1 Minimum Shift Manning Requirements 260a 6.10-1 Component Cyclic or Transient Limits 261 l

1 Amendment No...,

,, m, vi

- - - -. - _.~.

~-- - -- -.- -

.- - ~.-- - - -.- -

JAFNPP 1

4.0 BASES A.

This specification provides that surveillance activities C.

Continued necessary to inswa the Lanuting Conditions for Operation are met and will be performed during the OPERATIONAL interval, defined by the provisions of Specification 4.O.B. as a CONDITIONS (modes) for which the Limiting Conditions for condition that constitutes a failure to meet the OPERABILITY Operation are appkcalde. ' Prowlsions for additional swvestance reesirements for a Limiting Condition for Operation. Under the activition to be performed without regard to the applocable provisions of this specification, systems and components are OPERATIONAL CONDITIONS imodes) are provided in the assumed to be OPERABLE when Swveillance Requirements endewedual Swvemence Requirements.

have been satisfactorily performed within the specified time interval. However, notheng in this provision is to be construed B'

Specification 4.0.B estabhshes the limit for which the specified as implying that systems or components are OPERABLE when time interval for Survemence Requirements may be extended.

they am found or known to be inoperable although still it permits an allowable extension of the namel N meet % h N Rogsitements. This specification also interval to facilitate survedence schedsding and concederation clarifies that the ACTION requirements are appiscable when of plant operating condebons that may not be suitable for Survedence Requirements have not been completed within the conducting the surves5ence (e.g.. transeent conditions or other allowed survesitance interval and that the time limits of the ongoing m or maintenance activstees). It also ACTION requerements apply from the point in time it is provides Roxibility to accommodets the length of a fuel cycle identified that a surveeNance has not been performed and not for survestances that are performed at each refueling outage at the time that the allowed surveellence was exceeded.

and are specified with a 24 month survedence interval. It is Completion of the Survedlance Requirement within the i

not intended that this provision be used repeatedly as a sNowable outage time limits of the ACTION requirements convenience to extend survemence intervals beyond that restwas compliance with the regarements of Specification i

t t

specified for survesences that are not performed dunne 4.0.C. However, this does not negate the fact that the failure refueling outages. The lunetation of this specification is based to have performed the survenance within the allowed I

on angensonne y and the recognition that the most survedance interval, defined by the provisions of Specification probable result of any particular surveillence being performed 4.0.6, was a violation of the OPERABILITY requirements of a is the verification of conformance with the SurveiNance Limiting Condition for Operation that is subsect to enforcement t

Requirements. The limit on extension of the normal action. Furtherdhe failure telperform a surveillance within !

l surveillance interval ensures that the releability confirmed by provisions of Specification 4.0.8 is a violation of a Technical survedance activities is not significantly reduced below that Specification requirement and is, therefore, a reportable event obtaened from the specified survedance interval

(

)

under the requirements of 10 CFR 50.73(a)(2)(il(B) because it es a condition prohibited by the plant Technical Specifications.

C.

This specification establishes the failure to perform a Surveillance Requirement within the allowed surveillance

)

t

)

i m,q g move) b eca g o i

Amendment No. S3. ? 22.122 30e 1

INSERT A:

"The exceptions to Specification 4.0.B are those surveillances for which the 25% extension of the interval specified does not apply. These exceptions are stated in the individ Jal Technical Specifications. The requirements of regulations take precedence over the Techncal Specifications. Therefore, when a test interval is specified in the regulations, the test interval cannot be extended under the provisions of 4.0.B, and the surveillance requirement will be identified as an exception. An example of an exception when the test interval is not specified in the regulations is the Note in Specification 6.20, " Primary Containment Leakage Rate Testing Program", which states "The provisions of Specification 4.0.B do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program." This exception is provided because the program already includes provisions for extension of intervals."

p peov.s MC-M NPP i

t 4.0 BASES - Continued i

i C.

Continued C.

Continued

) If the allowable outa0s tismo Nuits of the ACTION requirements Surveillance Requirements do not have to be performed on are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or a shutdown is required to comply enoperable equipment because the ACTION requirements with ACTION requwements, a 2h allowa' ce is provided to define the remedial measures that apply. However, the

[

n permit a delay in implesneneing the ACTION requwements.

Surveellence Requirements have to be met to demonstrate that This provides an ada'Pa*= time Nmit to complete Surveoliance moperable equipment has been restored to OPERABLE status.

?

Requerements that have not been performed. The purpose of this aNowance is to permit the eT_;W of a survesRance j

before a shutdown is required to comply with ACTION D.

This specification estableshes the requirement that all requirements or before other remedeel measures would be apphcable surveellences must be met before entry into an I

required that may preclude completion of a surveillance. The OPERATIONAL CONDITION or other condition of operation basis for this aNowance encludes concedoration for plant specified in the Applicability statement. The purpose of this l

conditions, adequate plannme, availability of personnel, the specification is to ensure that system and component time required to perform the surveellence and the safety-OPERABILITY requirements or parameter limits are met before significance of the deley in completing the required entry into an OPERATIONAL CONDITION or other specified survesusace. This provision also provedes a time limit for the condition associated with plant shutdown as well as startup.

completion of SurvesNance Requirements that become applicable as a consequence of OPERATIONAL CONDITION Under the provisions of this specification, the applicable l

(mode) W imposed by ACTION requirements and for Surveellance Requirements must be performed within the completing Surveellence Requirements that are applecable wh specified surveiNance interval to ensure that the Limiting an exceptnen to the requirements of Specification 4.0.C is Conditions for Operation are met during initial plant startup or i

allowed. If a surveeNence is not completed within the 24-hour foNowing a plant outage.

allowance, the time limits of the ACTION requirements are applicable at that time. When a surveellence is performed When a shutdown is required to comply with ACTION I

within the 24-hour anowance and the Surveillance

equirements, the provisions of this specification do not apply Requerements are not met, the time limits of the ACTION becausa this would delay placing the facility in a lower requirements are applicable at the time the surveeHance es CONDITION of operation.

termaneted.

Amendment No. 40, Si, 33, t00,1S2,130, 22h 30f i

~.

-. _. ~.

3.7 (cor.t8d)

JAPNPP 4.7 (cont'd) o (2)

During testing s/nich adds heat to :he suppression paal, the water teeperatuic shall not exceed Ir,F above the no nal power oicration linit speci fic;l in (1), above.

In coar.cction seith si:ch testing, tlic pcal ter;ieraturc :r.ust be restuced to 1elaw tl.c noscal po:cr operation lirit specified in (1) chove seithin 3* n e r s' h

2. Lau (3) The reactor shall he scramned from any I

c;uratir.;; condition if the pool t'

te.mperca:re reaches 110F.

Poseer cpciatica shall not be resuned until 2-The 1:risery con t r.ir= cit t

the pcol ter.perature is reduced below integrity n; sal 1 lie. de;.va s i ra U:.1 the nar.al pa:cr operation 1imit as follotes:

f s; ecified in (1) ahuve.

l a.

Type A Test (pr ima ry t

(4)

Darin; reacter isolation conditions, Centainment II.t e:l t c.:

.1 ti;c reactcr pressure vessel sha,Il 1:a Leal; age :ta t e T.:ci-)

I depressuri:cil to less than 200 psi;;

r.t norr il coutiloten rates if the pe ol (1.) con ta i suaen t In ;pect ton t o pe rat ure reaches 120i'.

n h.il l 13 1 perfor me.1 a:.

a prer cq u i n: le to ih-2.

Pri-ary containment integrity shall be maintained p e r f o a ::a u c e of Tyi e-A at all tir.cs -i.cn t he reactor is critical or 5.hea t es t.S -

Durin.1 th2 the rea: tor water tenptrature is above 2120F, ar.d I.e r i oi t liet s cesa Ihe feel is in the reactor vessel, except while i n i t. i a t. i o n sli..

o, pe r fo r.ti n;; lo.:pc -cr 1.hysics tests at atuospheric c o a t.;j n;,,,.u t is: :pectnon press:rc at pc;.cr levels not to c:cced 5 !!ilt.

ii r n t TID-per for :.i n s c.-

o t'

\\

tlne

ype u I

1 CPd i 1 '-

or a.1 ;u:;t m. rit :.

S h.il I l e m.nic.

)

Amendment No. W 166

=

_ _ ~

. _ ~ _... -

l

[,

i INSERT B:

" 4.7. A.2.a Perform required visual examination and leakage rate testing of the Primary Containment in accordance with the Primary Containment ~

Leakage Rate Testing Program.

4.7. A.2.b Demonstrate leakage rate through each MSIV is _< 11.5 scfh when tested at A 25 psig. The testing frequency is in accordance with the Primary Containment Leakage Rate Testing Program.

4.7. A.2.c Once per 24 months, demonstrate the leakage rate of 10AOV-68A,B for the Low Pressure Coolant injection system and 14AOV-13A,B for the Core Spray system to be less than 11 scfm per valve when pneumatically tested at 145 psig at ambient temperature, or less than 10 gpm per valve if hydrostatically tasted at A1000 psig at-i ambient temperature."

l l

l s

4 4

i r

h

.TAFHPP 4.7 (cont'd)

(2.) Closure of containment i

isolation valves for the

(

Type A test shall be acccirplished by normal

)

operation and without any preliminary l

s exercising.

[ (,9 + bW C Il b

{

3 (3.)The containment test gg

[w do g

conditions shall i

stabilize for a period of about 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> prior i

to the start of a

leakage rate test.

(4.) Components to be tested as part of the i

containment shall be vented to the containment atmosphere.

j (S.) Test methods are to comply with ANSI N45.4-1972 paragraph 5 i

and leak rate i

calculations will comply with the intent of At1SI N45.4-1972 paragraph 5.

I The mass of air in the 4

containment will be

{

calculated hourly and the leak rate determined by a

linear least i

sq uares tit to the mass of air as a function of time.

1 167 i

(pJea

/5 l/

1 3c

s JAFMPP 4.7 (cont'd)

(6.) The accuracy of the Type A test shall in-verified by a

supplemental test as described in Appendix C of ANSI N45.4-1972,

}

or the metered addition of air into the containment p

after the end of the Type A test.

(7.) Test Pressure i

(a.) An initial test

(

shall be performed i

L at a 23 psig (Pt, reduced pressure) which is greater than 0.50 Pa to measure a leakage rate Ltm.

t l

(b.) A second test shall be performed at al% psig (Pa peak r*ssure) to measure leakage rate Lam.

i (c. ) The leakage characteristics yielded by ineasurements Ltm and Lam shall establish the maximum allowable test leakage rate Lt of not more than La (Ltm/ Lam).

In the event Ltm/ Lam is greater than 0.7, Lt shall be specifled I

as equal to La 168 VPt/Pa).

/

~

~.

y JAFNPP 4.7 (cont d) 8 i

(8.) Acceptance Criteria Reduced pressure tests.

Cul (Pt)

The leakage rate Ltm shall be less than O.75 Lt.

Pc-gd.-

o Peak pressure te.st.

(Pa)

The leakage rate Lam shall be less than 0.75 (La) and not greater than Ld, which is 0.5 weight percent of the contained air per 2ts hr at the test pressure Po.

(9.) Periodic leakage rate test sha11 be performed at reduced pressure (Pt) or at peak pressure (Pa).

(10.) Additional requirements If any periodic Type A test fails to meet the applicable i

acceptance criteria the test schedule applicable to subsequent Type A tests will be reviewed and

{

approved by the Commission.

11 two consecutive periodic Type A tests fail to meet the acceptance

criteria, a

169 N_

j

JAFNPP 4.7 (cont'd) i Type A test shaN be performed at each plant shutdown for refueling or approxirnately every 18 months, whichever occurs first. until two consecutive Type A tests meet the acceptance criteria.

I b.

Type B tests (Localleak rate testing of containment oh P

penetrations) t (1.) AN preoperational and periodic Type B tests shaN be performed by local pneumatic pressurization of the containment penetrations. either irwieviduaHy or in groups.

(

at a pressure not less than Pa. and the gas flow to maintain Pa shall be measured.

12.) Acceptance criteria f}

The combened leakage rate of au penetrations and valves subsect to Type 8 and C tests shan be less than O.60 La.

with the exception of the valves sealed with fluid from a seal system.

t l

I N

S.1 >9 An.endment No. 1 370

JAFNPP 4.7 (cont'd) c.

Type C tests hd L

(1.) Type C tests shall be performed by Qla.q 6 local pressurization. The pressure (j

shall be applied in the same direction as that when the valve would be required to perform its safety function, except as listed in Table 4.7-2 unless it can be determined that the results from the tests for a pressure applied in a different direction will provide equivalent or more conservative results.

Each valve to be tested shall be closed by normal operation and without any preliminary exercising or adjustments.

(2.) Valves, unless pressurized with fluid 1

from a seal system, shall be pressurised with air or nitrogen at a

pressure of Pa, and the gas flow to maintain Pa shall be measured.

(3.) Valves, which are sealed with fluid fross a seal system, such as the liquid in the suppression chamber shall not be

tested, f

mendmerit No. #. m -

q

/

nii

\\

t

'N JAFNPP 4.7 (cont'd)

{

(4.) See table 4.7-2 for exceptions.

k (5.) Acceptance criterion -.The combined leakage rate for all penetrations and

]qL valves subject to type B and C tests d

shall be less than 0.60 1.a.

Leakage from containment isolation valves that are sealed with **uid from a seal system may be excluded whsa determining the combined leakage rate provided that the installed isolation valve seal-water system iluid inventory is sufficient to assure the sealing function for at least 30 days.

bd.

Other leak rate tests (1)

The leakage rate for containment isola-tion valves 10-AOV-68A, B (penetration X-13A, 8) for Low Pressure Coolant Polc( A E injection system and 14-A0V-13A.B o ((g(,

V (penetration X-16A, B) for Core Spray System shall be less than 11 cubic feet

  • d N"g#

per minute per valve (pneumatically GS 4.7, A. J. C.

tested at 45 psig with ambient temper-ature) or 10 gallons per minute per valve (hydrostatically) tested at 1003 psig with ambient temperature.

b Amendment No. f. IM e

m_

)

. m.s---

E JA 4.7 (cont'd e.

Periodic retest schedule.

k (1.) Type A test.

After the preoperational leakage rate tests,.. a set of three Type A tests shall he

[

per f orraed, at approximately equal intervals during each 10-yea r service period.

i M

l f

Amendment 40 172a

,m="

m m -

-w.--

W-Pt m

m

~

,./

JAFhP C

/

~

4.7 (cont'd)

} [ {g,

[3,z p,-

The third test of each set shall be g

conducted when the plant for the 10 year plant is shutdown inservice inspections.

Permissible periods for testing.

performance of Type A tests shall be The limited to periods when the plant facility is nonoperational and secured in the shutdown condition under the administrative control and in accordance with the plant safety procedures.

(2) Type B tests, (except tests for air-locks), shall be performed during each reactor shutdown for refueling, or other convenient intervals, but in no case at intervals greater than 2 years.

s i

(3) Type B tests of airlocks shall be conducted at en internal pressure of not less than 45 psig (Pa).

The overall leakage rate for the airlock shall be less than or equal SCFD (0.05 La).

to 268 be conducted:

Airlock tests shall a) Every six months.

b) Prior to restoration of contain-ment integrity, when maintenance has been performed on the airlock which could affect capability.

its sealing

.i Amendinent No.

97

\\

173

\\

X'

J JAPNF L

4.7 (cont'd) g,_

c) Within three days of opening i

\\

i the airlock, when containment d

integrity is required and maintenance has been performed on the airlock which could a f fect its sealing capability.

i (4) Airlock seals shall be tested at a pressure not less than 45 psig.

I The seal leakage rate shall be less than or equal to 120 SCFD.

Airlock seal tests shall be con-ducted:

a) Prior to restoration of contain-ment integrity *. If maintenance which could affect sealing capa-bility was performed the entire airlock shall be tested as required by 4.7. A.2.e (3).

b) Within three days after opening the airlock, when containment integrity is required.

c) Once every three days, during periods of frequent openings when containment integrity is re-quired.

[ Anendrent Mo.

97 173a

\\

Exemption to 10 CFR S0, Appendi x J l

_,,,,,e---'-

/

JAFNPP f

Q.i 4.7 (cont *d) db (5) Type C test.

Type C tests shall be performed during each reactor shutdown for refueling but in no case j

at intervals greater than two years. "

  • I (6)

Other leak rate tests specified in Section 4.7 d shall be performed during each reactor shutdown for refueling but in no case at intervals greater than two years.

f.

Containment modification

  • Any major modification, replacement of a component which is part of the primary reactor containment boundary, or resealing a seal-welded l

door, performed after the preoperational leakage rate test shall be followed by either a Type A, Type

}

B, or Type C test, as applicable, for the area offacted by the modification. The measured leakage from this test shall be included in the test report.

The acceptmco criteria es appropriate, shall be met.

Minor modifications, replacements, or reseeling of I

seal-weided doors, performed directly prior to the conduct of a scheduled Type A test do not require a

[

separate test.

s

  • In accordance with an exemption from 10 CFR 50 Appendix J. a Type A, B, or C test is not required for the replacement of piping in accordance with an exemption from 10 CFR 50 A dix J

\\

and welds which constitute the Core Spray System minimum flow the Type C test of the shutdown cooling isolation va v s lines 13*-W23-152-7A, B) during the 1993 maintenance outage-(10MOV-17 and 10MOV-18) may be deferred until refuel"O

'\\

outage Reloa611/ Cycle 12.

k Amendment No. [,g, 5,1[,1[,

0, [ M l

174

. m m

m m

m

e r

i o

I I

I t

c$

\\

3 5 4s C

i rd s

i i

\\

b

\\

o

\\

w n s

dW O

i T

5\\

c kh

\\

i

~J i

\\,

JAFWrr 4.7 BASES (cont *d) l 7

\\

assunsption of so holdup in the secondary contai:n-seat, resulting la a direct release of fission

[ As most leakage and deterioration of integrity is

(

products from the Primary containment through the espected to occur through penetrations, especially i

those with resilient seals, a periodic leak rate filters and stack to the environs. Therefore, the specitled primary oesteissent leak rate and test program of such penetrations is conducted at filter efficiency are conservative and provide the peak pressure of 45 psig to insure not only

[

additional margia between espected offsite doses that the leakage renales acceptably low but also

^

and 10CFB100 guidelines.

that the sealing materials can withstand the accident pressure. For airlock leak test, a seal fThemanimumallowabletestleakrateatthepeak test at the peak pressure could be substituted i

for the complete airlock test, if no malatenance pressure of 45 psig (Pa) is 4.5 weight Percent pr day (1.am). The maalmum allevable test leak work is done which could affect the sealing

{

capability of the airlock.

{

rate at the reduced Pressure of 23 peig (P I t

will be verified to be conservative by acts.a1 i

l rimary containment leak rate measurements at The leak rate testing program was originally 1 hoth 45 pelg med 23 peig upon completion of the based on Commission guidelines for development of g

(

I l

leak rate testing and surveillance schedules for containment structure.

reactor containment vessels (16), and discussed f

)

y To allow a margia for possible leakage deterior-la Question 5.4 of the FsAa. seith the exceptions listed la Table 4.7-2. the system comforms to the ation between latervals, the manimum allowable latest Commission guidelines (17).

}

The esceptions l

leak rate (Ltm), which will be met to remala on stated in M e 4.b2 are necessary slace the normal test schedule, is 0.75 L. In addittomal requirements were added atter the

\\

t I

addition, it is intended to operate the primary ystem was designed.

containment structure at a slight positive Pressure to continuously monitor primary contain-R.

Etandby Gas Trea*===t System - '_

t

(

)

C.

Seco=^=rs Contni

-t g

most leakage.

t f

Initiating reactor building isolation and opera-i i

tion of the Standby Gas Treatment System to pseM C, maintain at least a 1/4 la. of water vacuum within the secondary contalement provides en adeguate test of the operation of the reactor Amendment No.

.W i

194 l

i l

l

INSERT C:

"The leakage rate testing program was originally based on NRC guidelines for development of leak rate testing and surveillance schedules for reactor containment vessels.

Containment structural integrity is currently verified with visual inspections and containment leak tightness is verified by the leakage rate surveillance testing described in the JAFNPP Primary Containment Leakage Rate Testing Program.

The following are the exemptions to 10 CFR 50 Appendix J, Option A, that have been approved by the NRC, and remain applicable to Option B of 10 CFR 50, Appendix J:

i 1.

The Type C exceptions listed on Table 4.7-2, " Exception to Type C Tests," as of the date of issuance of Amendment 194 (July 29,1993).

2.

Valves which are sealed with fluid from a seal system, such as the liquid in the j

suppression chamber are not required to be Type C tested. This exemption was approved by the NRC in the original Technical Specifications (SR 4.7.A.2.c(3)).

3.

The MSIVs are tested at a pressure less than P and 2. 25 psig, with a leakage rate acceptance criteria of _< 11.5 scfh per valve. This exemption was approved by the NRC in the original Technical Specifications (Table 4.7-2)."

The Program as implemented meets the requirements of Option B of 10 CFR 50 Appendix J (16) and Regulatory Guide 1.163(13), with the exception stated in Specification 6.20.

This exception applies to valves currently installed in this configuration, and does not apply to new installations. This exception is consistent with TS Table 4.7-2, previously contained in the TS, which allows reverse direction testing of valves as an exception to the requirements of the draft Appendix J, on the basis that pressurization direction was not a requirement at the time of plant design."

w a-

+ man a

a 0

O n

7 i

.R Y,

t E

II i l 9

Y Yx 4

E

..-..~.-.-.--.~~----- - _.-.-

%.u,.

's N

N s

\\

i i

t l

'l I

l l

\\

(

5 o '\\

sI

-z a

W t

\\

I s

'\\

a s

a S

> v g

b

\\

\\

W 's fR

.lAFNPP TABLE 4.7-2 EXCEPTION TO TYPE C TESTS t

The logowin0 penetraelons are -P frorn Type C teasing requirements riuTAINbdENT

. % vaunusuus VALVE a rm LEAK RATE TEST PERFORGAED I

PENETRATION FUIICTIOIs NR

}

7A mm 29AOV-80A The inhoard weeves we be tested in the reverse dire 78 29AOV408 appmed between the innassanri velves and leakage measured. A wa 7C 29AOV40C

(

of 25 peig we be used on she inboard veeve to determine the oimbo 7D 29AOV-8cD volve's leek rese: Simit t t.5 SCFH at 25 peig )

/

29AOV46A I

i 29AOV488 I

i 2 Ov4.c f

2.Aov4eD 25 g

27AOV-112 These velves wt be tested h the reverse direction r et Wand /or 27AOV-131A 27AOV-13tB i

)

26A & 288 Dryweg Purge 27AOV-113 These velves wW be tested in the reverse dkW e

Irdes (Airand/or 27t40V-122 i

Nerogen)

\\

l l

acA instrumentanon h

We not be tested as lines are sealed by process Ruid.

l l

36g Tc.J.u 07EV-104A This volve is an ar% sheer valve which cannot be Type C res 1

infore Probe "A*

I I

I

(

I

/

t t

1I t

/

i Amerdment No. f.. If. If.1[, 161 b

\\

.menre N l

[f

~~

~~

a8LE 4.7-2 N

h

(,

EXCEMION TO TYPE C TESTS CONTApthEldT VALVE POETRATION PENETRATION FUNCTION Dem81 LOCAL LEAK RATE TEST PERFORMED

\\

i 35C Trewersing imCese Protse "C" 07EV-104C t

This veiwo is en engeloorwe sheer velve which cannot lie Type C tested

)

350 Trowersing InCare Prahe "B" 07EV-1048 I

I This velve is en engloews sheer wetwo whch cannot he Type C tested t

l i

37A Central Red Orlwe N-1 M M not b W es h h me 137 h 2 31 t

,,,,,,,,,,i,,,,,,

03Sov-i23 38 h p poneere en. and ee. hes = io.,

-. we wesi.e e.eied hv

(

37C

-128 pecess M 370 II" 38A Central Red Ddwo 03SOV-121 l

WE not he tested as lines tihere are 137 lines, with 3(

t see Ishows pienent 03SOV-122 gieneensden, and ee. has em three hdicated ve6wes) we emelmi try 03AOV-127 process Guid.

380

{

l i

3sA RHR Cent. Sprey 10MOV-31A This volve wW be tested in the roweres h.

333

, RDWI Cent. Sprey 10MOV-31s This watwo we age tested in the roweres drection.

I i

45 DryuseB Ptemense sensing 16-1AOV-101 A This watwo wW he tested in the toweree direction.

(

k i

SOC Innenenenteelen - Seneine Vedeus i

Thees insenenent root volves are tested durfte a Type A test./

i DW Puesoure I

/

i

?

Asnendenent No.

1

1. 194

/

/

~

1

.... ~'

LT 1

1

/

.i I

I

.i l.al l

1 1

1 a

1 I

I g 1 1

1 1

1 i

1 1

l 1 1 1

jl I J J

Il li q.

j

-l l

il 11 11 !!!!!!!Il !!lilll!! !

I le j

Il Il I

I l

1 1 1

lte 1 1j I 1

}

}

t 11 111 1 I i l i l 1

a r

j' i

gi r-y--

2--g

1 6

.-+-

'**%w---~

W l'[

l

)

i i j

.I l

l I l >lI l

}l l

l l

1 1

( f.! !

l l

1 i

n n

i i

n r

g n

l g

E.

8 8

8 8

8 4

.i i

1 I I

I 1

5 g

,;I i

i i

i i

v.

i ss I.

1 s

s. si si si a

l

! -a na un

\\

= 11 !

l ili l l ll ili ll!

\\

3 ll 3

I,}

i n

1 ll l it 1 11 11 11 I

i 1

l a,l l h n u nt s.. il t

E i

a a

a a

n i

I

.ia 1

'y u

Q

,.-m

J N

~

TABLE 4 7 ?

EXCEPTION TO TYPE C TESTS

~~ '- -s s

s CONTAINMENT P5~NETRATION VALVE

\\

LOCAL LEAK RATE TEST PERFORidED PENETRATION FU_NC.T. ION NUMBER 2?6 HPCI - Pump Suction 23MOV 57 Wdi not be tested as lines are water scaled by suppressum chamber (Torus) 23MOV 58

{

i 227A Core Spray - Pump 14MOV 7A Soci on (Torus)

Wdi not be tested as Ime is water sealmi by suppression chamber wate f

i

{t 227B Core Spray - Pump 14MOV-78 j-Sig tum (Torus)

Wdi not be tested as line is water sealed by suppression chamber wates

{

ppg Condensate to Torus 33CND 102 Wdi not be tested as ime is water sealed by suppression chamber wat I

I

/

Dne i

K

/

/

/

l

/

s j

(

Ani. s ulm.

I43

~

p

- - ~ ' " -

POSTkCCIDENTSAMPt.IWCPROGRAM 6.19 1

A progreat shall be established, implemented, and maintained which will ensure the capability to obtain and analyse reactor coolant, Lodines and particulates in plant gaseous effluents, and containment radioactive staosphere samples under accident conditions.

the following The program shall include i

A) Training of personnel, B)

Procedures for sampling and analysis.

f c)

Provisions for maintenance of sampling and analysis l'#

Casever D 4

Amendment No.

1 u.e

O INSERT D:

"6.20 Primarv Containment Leakaae Rate Testino Proaram A program shall be established to implement the leakage rate testing of the Primary Containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, " Performance-Based Containment Leak-Test Program," dated September 1995, as modified by the exception that Type C testing of valves not isolable from the containment free air space may be accomplished by pressurization in the reverse direction provided that testing in this manner provides equivalent or more conservative results than testing in the accident direction. If potential atmospheric leakage paths (e.g., valve stem packing) are not subjected to test pressure, the portions of the valve not exposed to test pressure shall be subjected to leakage rate measurement during regularly scheduled Type A testing. A list of these valves, the leakage rate measurement method, and the acceptance criteria, shall be contained in the

Program, A.

The peak Primary Containment internal pressure for the design basis loss of coolant accident (P,), is 45 psig.

B.

The maximum allowable Primary Containment leakage rate (L,), at P, shall be 0.5%

l of primary containment air weight per day.

C.

The leakage rate acceptance criteria are:

j 1.

Primary containment leakage rate acceptance criteria is i 1.0 L,.

During unit startup following testing in accordance with this program, the leakage rate acceptance criteria are 10.60 L, for the Type B and Type C tests and 10.75 L, for the Type A tests 2.

Airlock testing acceptance criteria are:

a.

Overall airlock leakage rate is 10.05 L, when tested at A P.,

b.

For each door seal, leakage rate is i 120 scfd when pressurized to A P,.

3.

MSIV leakage rate acceptance criteria is i 11.5 scfh for each MSIV when tested at 125 psig D.

The provisions of Specification 4.0.B do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program.

E.

The provisions of Specification 4.0.C are applicable to the Primary Containment Leakage Rate Testing Program."

JAFl@P 12,y Lhe Go. a s. 1. u.I, " P,4m.

G.aa c.)or. a w.-ncr l

7.0 REFERENCES

Pro 3c-l' A,le3 See 6k<c 1995 (1)

E. Janssen, "Muld-Rod Bumout at Low Pressure," ASME Paper (9)

C.H. Robbins, " Tests of a Fuu Scale 1/48 Segment of the 62-HT-26, August 1962.

W Boy Pmesure H-p - " -, Containment," GEAP-3596, l

November 17,1960.

(2)

K.M. Becker, "Bumout m lor h d Boung WM verscal Rod Cksters," AE-M (SincI8mbn Sweden), May 1982.

(10) hear Safety Program Annual Progmas Report for Pedod Endng December 31,1908 Progrees Report for Pedad Ending (3)

FSAR Section 11.2.2.

December 31,1986. OR94A071."

(4)

FSAR hreinn 4.4.3.

(11) Sesalon 5.2 of me FSAR.

(5) 1.M. Jacnha, "Reuebaty of Engineered Seisty Features as a (12) TID 20683, "Lankage Chorectadoucs d Steel Containment Func60n of Testin9 reepsency

  • Nudeer Soesty, Vol. 9 No. 4 Vessel and me Analysis of LaelW0s Rate Determinadons."

F July-August 1988, pp 310-312.

M (13) Tedmical Safety Guide, " Reactor Conseinment Leekage Testing '

)(6)

Deleted d

W," N. DMeion of Safey Standents, Redsett Draft. December 15,1966.

(7) 1.M. Jacobs and P.W. Madott, APED Giddeunes for C r -..:. Aq

_M(

Safe Test intervals and Repair Times lor Engneered Safeguards (14) Secean 14.6 of me FSAR.

- Apes 19e9.

(15) ASME Boller and Pressure Vessel Code, Nudear Vessels, (8)

Bodega Bay Preliminary Harants % Appens3x 1. W Secuan m. h M intemet pressure is 62 psig.

50 20s, Decemter 28,1982.

~-

(16) 10 CFR 50.54, Appendx J. " Reactor Containment Tesung~

@equimments "

(17) 50, Appent3x J. February 13,1973.

D c A 4< &

w?/o q p R i% 4 50 Appw c/s x

fr* **j 7

ld'

' C a ku, m+ Le Lye. To1 h af Sc uL 4, Go leg t%<r 2ac].cs o +oa B-RcLm-e LuS r

Reyv,< ~ Q,* f/M 6< J A oc u ta,.x,19 9 5 Amendment No. 1)lb, I

Attachment IV to JPN-96-031 APPENDIX J OPTION B IMPLEMENTATION PLAN (JPTS-96-003)

.I i

j i

i i

d New York Power Authority JAMES A. FITZPATRICK NUCLEAR POWER PLANT Docket No. 50-333 DPR-59

Attachment IV to JPN-90-031 APPENDIX J OPTION B IMPLEMENTATION PLAN Page 1 of 5 INTRODUCTION Option B of 10 CFR 50, Appendix J (Option B) provides a performance based approach for leakage rate testing of primary containment. This action improves the focus of the regulation by eliminating prescriptive requirements that have been determined to be marginal in safety.

Option B allows for test intervals to be established based on system and component performance and provides for greater flexibility for cost effective implementation methods of regulatory safety objectives.

This plan outlines how the Authority will incorporate Option B into the Primary Containment Leakage Rate Testing Program (the Program) for Type A, B and C testing at the FitzPatrick plant. The Authority will comply with the requirements contained within References 1 through 4.

COMPONENT LEAKAGE LIMITS Fitzpatrick will set administrative limits for each Appendix J component and develop the procedures for changing them. The existing plant administrative limits will be reviewed and compared against consistent limits set by the FitzPatrick Maintenance Rule Expert Panel.

A component's measured leakage is compared against its administrative limit to determine whether the As-Found LLRT passed or failed on a performance basis. The expert panel will review and approve administrative leakage rate limits since the proper setting of these limits is extremely important under the performance-based rule. Comparison of a components As-Found leakage against the administrative limits will determine if a test passed or failed, thus, the values chosen will affect each component's Type B or C testing frequency.

Two limits, a warning limit and an alarm limit, will be specified for each component. A component should be repaired if the As-Found leakage rate is above the warning limit, but below the alarm limit. If repaired, an As-Lef t test will be conducted. The As-Found test is not counted as a performance failure, if a component's leakage rate is above the alarm limit, then the component shall be repaired. The component will be retested after the repair. The As-found test is counted as a performance failure. This scheme allows for a low leakage setpoint to trigger component repairs so as to maintain containment in good condition, it also allows for the alarm limits to be set high enough that a Type B or C As-Found test need not be counted as a failure unless the component is found in a seriously degraded condition.

i Although administrative limits are used to maintain the containment in good condition, it should be noted that the sum of the As-Left Maximum Pathway Leakage Rates for all Appendix J barriers must be less than 0.6 La per plant Technical Specifications (TS) prior to entering a mode requiring primary containment integrity. In past instances where leakage from one or more components have exceeded administrative limits, and correcting this condition would have either been very difficult or costly, a total containment leakage evaluation was performed and documented. If the evaluation concluded that the additional leakage posed no significant safety impact, and the TS limit of 0.6La was not exceeded, the component (s) was(were) allowed to continue to leak in excess of the individual valve leakage

Attachment IV to JPN 96-031 APPENDIX J OPTION B IMPLEMENTATION PLAN l

Page 2 of 5 l

l administrative limit until repairs could be made. The test is still considered to be a failure i

because the administrative alarm limit was exceeded. The Authority reserves the option to continue use of this criteria when the alarm limit is exceeded, only on a critical as needed basis.

SUILDING PERFORMANCE BASELINES / ESTABLISHING TEST FREQUENCIES Tyne A Test I

Type A testing procedures will be revised per the new Option B requirements, and shall be performed during a period of reactor shutdown at a frequency of at least once per 10 years l

based on acceptable performance history. Acceptable performance history is defined as completion of two consecutive periodic Type A tests where calculated performance leakage rate was less than 1.0 La. Elapsed time between the first and last tests in a series of consecutive satisfactory tests used to determine performance shall be at least 24 months.

Option B allows for reviewing performance history with several options to determine if past Type A tests were satisfactory.

a.

As Found Type A test results can be compared to 1.0 La rather than the previous 0.75 l

La criteria.

b.

Leakage savings (repairs / adjustments) from type B and C testable pathways which j

were added as penalties to the As-Found Type A test can be subtracted when reviewing previous Type A test results.

c.

The Type A test UCL from previous Type A tests may be recalculated using the Mass Point Methodology described in ANSl/ANS 56.8-1994.

The Authority has reviewed Type A test results for the FitzPatrick plant as compared to the new requirements / criteria to establish a test frequency for the Primary Containment Integrated Leak Rate Test (ILRT). It has been determined that the two most recent As-Found l

Type A tests (1990 and 1995) are below the 1.01.a criteria. Leakage savings (repairs / adjustments) from Type B and C testable pathways which were added as additions to the As-Found Type A test were not subtracted. Based on this, Fitzpatrick willimplement the 10 year Type A test frequency based on the criteria set forth in the new rule. The Type A test interval may be extended by up to 15 months, however, this option will only be used in cases where refueling schedules have been changed to accommodate other factors.

fs

i e

Attachment IV to JPN 96-031 APPENDIX J OPTION B IMPLEMENTATION PLAN Page 3 of 5 Appropriate administrative controls have been developed such that prior to initiating a Type A test, a visual examination shall be conducted of accessible interior and exterior surfac.es of the containment system for structural problems which may affect either the containment structure integrity or the performance of the Type A test. These containment inspections will also be conducted during two other refueling outages before the next Type A test.

Therefore, FitzPatrick will perform these examinations at least three times every ten years, regardless of the Type A test schedule.

Tvoe B and C Test The Authority will develop a procedure for building and documenting Type B and C testing performance baselines for the FitzPatrick plant. This procedure will be used to ensure that a consistent criteria is applied to establish component baseline performance and their subsequent testing frequencies. The Authority will develop bases for test frequencies based upon performance of leakage tests that meet the requirements of Option B and approved exemptions. In addition historical performance, considerations such as service life, environment, design, system applicatiori, special service conditions, and safety impact / risk from failure will be reviewed / evaluated in determining test frequency. The component's perforrnance history will determine its test interval.

The Authority will compile the required leak rate historical data and continue to update this data with the most current As-Found leak rate data. The performance history of each component will be evaluated against the alarm limit to rate component performance over the last two refuel outages.

Type S components which are determined to have a performance rating of unknown, poor, or improving, will require a 30 month test frequency. A rating of good or excellent allows for up to a 120 month test interval. The component will be evaluated to determine if it is a member of a group of components subject to the same common mode failure mechanisms. If so, then the test intervals of all members of that group will be staggered, such that some percentage of those components are tested periodically. The date of the next test may be earlier than required by the baseline interval for this reason. The Authority intends to place good or excellent performing Type B components on a 120 month test interval. The test frequencies of similar/ grouped components will be staggered to ensure that a percentage of components are tested periodically.

Type C components which are determined to have a performance rating of unknown, poor, or improving, will require a 30 month test frequency. A rating of good or excellent allows for up to a 60 month interval.

Per NRC Regulatory Guide 1.163, the NRC does not endorse extended test intervals of greater than 60 months for Type C tests. Further, the Regulatory Guide states that Type C tests for Main Steam and Feedwater isolation valves and containment purge and vent valves, should be limited to 30 months with consideration given to operating experience and safety significance. The Authority intends to fully comply with this guidance by performing Type C tests on Main Steam, Feedwater, and Containment Vent and Purge isolation valves at a 30

e 9

e Attachment IV to JPN 96-031 APPENDIX J OPTION B IMPLEMENTATION PLAN Page 4 of 5 month interval with consideration given to operating experience and safety significance.

Type B and C testing intervals may be extended by 25 percent of the interval, not to exceed 15 months, however, this option will only be used in cases where refueling schedules have been changed to accommodate other factors.

The Authority will place the primary containment airlock on a test frequency of at least once per 30 months. Airlock door seals will be tested within seven days after each containment access when primary containment integrity is required. For periods of multiple containment entries where the airlock doors are routinely used for access more frequently than once every seven days, door seals may be tested once per 30 days during this time period.

FAILURES, REPAIRS / ADJUSTMENTS, CORRECTIVE ACTIONS Failures, repairs / adjustments, and corrective actions for Type A, B, and C testing results will be evaluated through the Deviation Event Report process.

if Type A performance leak rate test results are not acceptable, then a determination will be performed to identify the cause of unacceptable performance and determine appropriate corrective actions. Once the cause has been determined, and corrective actions have been completed, acceptable performance should be reestablished by performing a Type A test within 48 months following the unsuccessful Type A test. Following a successful Type A test, the surveillance frequency may be returned to once per 10 years.

Type B or C component failures discovered during performance of the Type A test will be considered as failure of a Type B or C test for purposes of cause determination and corrective action. This includes failures of type B and/or C components that were not previously identified by a Type B or C test.

Type B and C component failures will require that testing frequency be set at the baseline test interval of 30 months. A cause determination will be performed and corrective actions identified that focus on those activities that can eliminate the identified cause of failure and prevent recurrence. Once the cause determination and corrective actions have been completed, acceptable performance should be reestablished and the testing frequency returned to the extended interval in accordance with the NEl 94-01 guidance.

In addition to the periodic As-Faund Type B and C test, an As-Found test shall be performed prior to maintenance, repair, modification, or adjustment activity if the activity could adversely affect the penetration leak tightness. An As-Left Type B or C test shall be performed following those activities, unless engineering analysis shows reasonable assurance that such work does not affect the leak tightness of the penetration and that it can still perform its intended function. Specifically for Type C tests, an alternative method or analysis can be used to provide reasonable assurance that such work does not affect a valve's leak tightness and a valve will still perform its intended function. if As-Found and As-Left Type B and/or C results are both less than the allowable administrative limit, a change in testing frequency is not required. If the results are unacceptable, testing shall continue at initial test intervals until adequate performance history is reestablished.

a i

l Attachment IV to JPN 96-031 APPENDIX J OPTION B IMPLEMENTATION PLAN Page 5 of 5 l

TECHNICAL CRITERIA AND TESTING METHODOLOGY INTERPRETATION Changes to the leak rate testing program will be required regarding testing methodology and procedural requirements under Option B. The technical details / criteria and testing methodology as described in ANSI /ANS 56.8-1994 will be used in updating the FitzPatrick Type A, B, and C leak rate testing program.

REFERENCES 1.

Regulatory Guide 1.163, Performance-Based Containment Leak-Test Program, dated September 1995 2.

Option B of 10 CFR 50 Appendix J, Primary Reactor Containment Leakage Testing for Water Cooled Power Reactors (60 FR 49495) 3.

NEl 94-01, Industry Guideline for implementing Performance-Based Option of 10 CFR l

50 Appendix J, Rev. O, dated July 26,1995 4.

ANSI /ANS-56.8-1994, Containment System Leakage Testing Requirements I

s I

e o

Attachment V to JPN-96-031 LIST OF COMMITMENTS Commitment No.

Description Due Date JPN-96-031 01 DELETED JPN-96-031 -02 Revise plant procedures to incorporate August 1,1996 or a soap bubble test during ILRT for the prior to implementa-17 containment isolation valves listed tion of amendment.

in Table 1, utilizing the acceptance criteria of zero bubbles.