Proposed,Deleted TS Figures 5.2-1, DBNPS Exclusion Area, 5.1-2, DBNPS Low Population Zone, Figure 5.1-3, DBNPS Unrestricted Area Boundary for Liquid Effluents & Figure 5.1-4, DBNPS Unrestricted Area Boundary for Gaseous..ML20105C603 |
Person / Time |
---|
Site: |
Davis Besse |
---|
Issue date: |
09/11/1992 |
---|
From: |
CENTERIOR ENERGY |
---|
To: |
|
---|
Shared Package |
---|
ML20105C562 |
List: |
---|
References |
---|
NUDOCS 9209220320 |
Download: ML20105C603 (9) |
|
|
---|
Category:TECHNICAL SPECIFICATIONS
MONTHYEARML20216E6111999-09-0707 September 1999 Proposed Tech Specs 3/4.3.2.1 Re Safety Features Actuation Sys Instrumentation & Associated Bases ML20210H0731999-07-28028 July 1999 Proposed Tech Specs 3/4.7.5.1, Ultimate Heat Sink, Allowing Plant Operation in Modes 1-4 with Water Temp Less than or Equal to 90 F ML20210G4311999-07-27027 July 1999 Proposed Tech Specs,Changing TSs 6.4, Training, 6.5.2.8, Audits, 6.10, Record Retention, 6.14, Process Control Program & 6.15, Odcm ML20210G4801999-07-26026 July 1999 Proposed Tech Specs 3/4.3.2.1 Re Safety Features Actuation Sys Instrumentation & Associated Bases ML20210G9161999-07-26026 July 1999 Proposed Tech Specs 3/4.3.3.1, Radiation Monitoring Instrumentation, 3/4.3.3.2, Instrumentation - Incore Detectors & 3/4.3.3.9, Instrumentation - Waste Gas Sys Oxygen Monitor ML20210G5391999-07-26026 July 1999 Proposed Tech Specs Re Implementation of 10CFR50,App J, Option B for Type B & C Containment Leakage Rate Testing ML20195F9351999-06-10010 June 1999 Proposed Tech Specs,Revising TS 3/4.6.4.4, Hydrogen Purge Sys, TS 3/4.6.5.1, Shield Bldg Emergency Ventilation Sys & TS 3/4.6.5.1, Crevs ML20207E7941999-05-21021 May 1999 Proposed Tech Specs Allowing Use of Expanded Spent Fuel Storage Capability ML20205E5031999-03-19019 March 1999 Proposed Tech Specs Withdrawing Proposed New Action B, Previously Submitted in 981027 Application ML20204F1821999-03-0909 March 1999 Proposed Tech Specs,Adopting Changes in Frequency & Scope of Volumetric & Surface Exams Justified by W TR WCAP-14535A ML20155E3231998-10-28028 October 1998 Proposed Tech Specs Revising Various Sections of 6.0, Administrative Controls, Including Relocation of 6.11 Contents to Plant Ufsar,Per NUREG-1430,Rev 1 ML20155E4971998-10-28028 October 1998 Proposed Tech Specs 4.0.2 Re Applicability of 25% Surveillance Interval Extension Allowance ML20155D7791998-10-27027 October 1998 Proposed Tech Specs Relocating TS SR 4.6.5.1.d.4 Re Evs Negative Pressure Testing to TS 3/4.6.5.2,deleting TS Definition 1.24 & Making Related Changes Associated with Deletion of Subject Definition ML20155E0721998-10-27027 October 1998 Proposed Tech Specs Revising 3/4.3.1.1 Re RPS Instrumentation & 3/4.3.2.3 Re ARTS Instrumentation,To Provide Potential Reduction in Spurious Trip Rate for Potential Cost Savings in Excess of $50,000 ML20155D8521998-10-27027 October 1998 Proposed Tech Specs Revising SRs 4.8.2.3.2.d,4.8.2.3.2.e, 4.8.2.3.2.f & Table 4.8-1 Re Testing of 125 Volt DC Station Batteries & Applicable TS Bases ML20151W2991998-09-0808 September 1998 Proposed Tech Specs Revising Section 3/4.7.6, Plant Systems - CREVS & Associated Bases ML20151W3071998-09-0808 September 1998 Proposed Tech Specs Permitting Use of Framatome Cogema Fuels M5 Advanced Alloy for Fuel Rod Cladding & Fuel Assembly Spacer Grids ML20217P8351998-04-24024 April 1998 Proposed Tech Specs Clarifying Discussion of Margin Between RPS High Pressure Trip Setpoint & Lift Setting for Pressurizer Code Safety Valves ML20217P8811998-04-24024 April 1998 Proposed Tech Specs 3/4.3.1.1,3/4.3.2.1,3/4.3.2.2 & Associated Bases Relocating Tables of Response Time Limits to Plant USAR Technical Requirements Manual ML20217C4881998-03-20020 March 1998 Proposed Tech Specs SR 4.4.5.3.c.1,providing Greater Specificity as to Location of Addl Insps in Unaffected SG ML20217N4471998-02-27027 February 1998 Proposed Tech Specs Pages Provided to Modify Proposed New Action 3.7.6.1.b to Make More Consistent w/NUREG-1431 ML20203L1111998-02-26026 February 1998 Proposed Tech Specs Pages Re Amend to License NPF-3 Involving Incorporation of New Repair Roll Process for SG Tubes W/Defects in Upper Tube Sheet ML20197J2621997-12-23023 December 1997 Proposed Tech Specs Pages Re Changes to TS Definition 1.2, TS 3/4/9.5 & New TS 3.0.6 & Associated Bases.Ts Index Rev to Reflect Change to TS 3/4.9.5,included ML20197J5971997-12-23023 December 1997 Proposed Tech Specs Pages,Revising TS Surveillance Requirements for ISI Requirements of Internal Auxiliary Feedwater Header,Header to Shroud Attachment Welds & External Header Thermal Sleeves ML20217R2821997-08-26026 August 1997 Proposed Tech Specs,Clarifying LCO 3.6.1.3.a & Revising Surveillance Requirement 4.6.1.3.c ML20217R2871997-08-26026 August 1997 Proposed Tech Specs,Modifying TS 3.2.5 Action Statement to Require Power Reduction to Less than 5% of Rated Thermal Power within Four Hrs If RCS Flow Rate Is Less than Specified Limit for Greater than Two Hrs ML20217G5981997-07-29029 July 1997 Proposed Tech Specs 3/4.4.3 Re Safety Valves & Pilot Operated Relief valve-operating ML20141F1101997-06-24024 June 1997 Proposed Tech Specs,Deleting Requirements for Safety Features Actuation Sys Containment High Radiation Monitors ML20138C3261997-04-18018 April 1997 Proposed Tech Specs 3/4.7.6 Revising Limiting Condition for Operation to Include New Required Actions in Event That One or Both Channels of Radiation Monitoring Instrumentation Becomes Inoperable ML20138A6891997-04-18018 April 1997 Proposed Tech Specs 3/4.5.3.2.1 & 3/4.5.2 Modifying Presently Specified 18-month Surveillance Frequencies to New Specified Frequencies of Once Each 24-months ML20138M1281997-02-14014 February 1997 Proposed Tech Specs 3.5.2 Re Emergency Core Cooling Systems & 4.5.2.f Re Surveillance Requirements ML20134L0561997-02-13013 February 1997 Proposed Tech Specs Re Changes Made Concerning Decay Heat Removal Sys Valve ML20134D7621997-01-30030 January 1997 Proposed Tech Specs Revising SR Intervals from 18 to 24 Months Based on Results of DBNPS Instrument Drift Study & TS 2.2, Limiting Safety Sys Settings, Based on Results of Revised Framatome RPS Instrument String Error ML20134F1811997-01-30030 January 1997 Proposed Tech Specs Re Possession & Use of SNM as Reactor Fuel ML20134B0591997-01-20020 January 1997 Proposed Tech Specs 3/4.5.3 Re ECCS Subsystems ML20132B7031996-12-11011 December 1996 Proposed Tech Specs Revising TS Definitions,Instrumentation TS & ECCS TS for Conversion to 24 Month Fuel Cycle for License NPF-3 ML20134F1891996-10-28028 October 1996 Proposed Tech Specs 3/4.8 Re Electrical Power Systems ML20117P5311996-09-17017 September 1996 Proposed Tech Specs,Supporting Conversion of DBNPS from 18 Month to 24 Month Fuel Cycle ML20117N8531996-09-12012 September 1996 Proposed Tech Specs Re Reactivity Control Systems & Emergency Core Cooling Systems ML20117M2201996-09-0404 September 1996 Proposed Tech Specs 6.2.3,removing Specific Overtime Limits & Working Hours ML20116K2631996-08-0707 August 1996 Proposed Tech Specs Re Definitions,Applicability Bases, Containment Spray Sys & Containment Isolation Valve for Conversion to 24 Month Fuel Cycle ML20117K1911996-05-28028 May 1996 Proposed Tech Specs 3/4.3.1.1 - RPS Instrumentation & TS 3/4.3.2.3 - Anticipatory RTS Instrumentation Increasing Trip Device Test Interval ML20101M1921996-03-29029 March 1996 Proposed Tech Specs 3/4.6.4.4 - HPS,3/4.6.5.1 - Shield Building Evs & 3.4.7.6.1 - CREVS Re Changing Surveillance Requirements for Charcoal Filter Lab Testing to Revise Methodology Used to Determine Operability in ESF AHUs ML20101C6961996-03-0606 March 1996 Proposed Tech Specs,Allowing Deferment of SR 4.5.2.b for ECCS Flowpath Containing HPI Pump 1-2 Until 10th Refueling Outage,Scheduled to Begin 960408 ML20100E0101996-02-0505 February 1996 Proposed TS 3/4.3.2.1,Table 3.3-3,safety Features Actuation Sys Instrumentation,Reflecting Design & Actuation Logic of Plant Sequencers & Essential Bus Undervoltage Relays ML20095F5891995-12-12012 December 1995 Proposed Tech Specs Re Containment Sys ML20094D0611995-10-31031 October 1995 Proposed TS Page 6-18,deleting TS 6.9.2.d, Seismic Event Analysis ML20098C5181995-10-0202 October 1995 Proposed Tech Specs,Revising TS Section 5.0,design Features & Adopting Improved STS for B&W Plants Format & Content ML20098C4111995-09-29029 September 1995 Proposed TS 3/4.1.2.8 Re Reactivity Control Sys - Borated Water Sources - Shutdown TS 3/4.1.2.8 Re Reactivity Control Sys - Operating & TS 3/4.5.1 Re ECCS - Core Flooding Tanks ML20098C1121995-09-29029 September 1995 Proposed TS 3.4.3 & Associated Bases,Modifying Lift Setting of Pressurizer Code Safety Valves to Greater than or Equal to 2,575 Psig,Corresponding to Lift Setting Tolerance of +3% of Nominal Lift Pressure 1999-09-07
[Table view] Category:TECHNICAL SPECIFICATIONS & TEST REPORTS
MONTHYEARML20216E6111999-09-0707 September 1999 Proposed Tech Specs 3/4.3.2.1 Re Safety Features Actuation Sys Instrumentation & Associated Bases ML20210H0731999-07-28028 July 1999 Proposed Tech Specs 3/4.7.5.1, Ultimate Heat Sink, Allowing Plant Operation in Modes 1-4 with Water Temp Less than or Equal to 90 F ML20210G4311999-07-27027 July 1999 Proposed Tech Specs,Changing TSs 6.4, Training, 6.5.2.8, Audits, 6.10, Record Retention, 6.14, Process Control Program & 6.15, Odcm ML20210G4801999-07-26026 July 1999 Proposed Tech Specs 3/4.3.2.1 Re Safety Features Actuation Sys Instrumentation & Associated Bases ML20210G9161999-07-26026 July 1999 Proposed Tech Specs 3/4.3.3.1, Radiation Monitoring Instrumentation, 3/4.3.3.2, Instrumentation - Incore Detectors & 3/4.3.3.9, Instrumentation - Waste Gas Sys Oxygen Monitor ML20210G5391999-07-26026 July 1999 Proposed Tech Specs Re Implementation of 10CFR50,App J, Option B for Type B & C Containment Leakage Rate Testing ML20195F9351999-06-10010 June 1999 Proposed Tech Specs,Revising TS 3/4.6.4.4, Hydrogen Purge Sys, TS 3/4.6.5.1, Shield Bldg Emergency Ventilation Sys & TS 3/4.6.5.1, Crevs ML20207E7941999-05-21021 May 1999 Proposed Tech Specs Allowing Use of Expanded Spent Fuel Storage Capability ML20205E5031999-03-19019 March 1999 Proposed Tech Specs Withdrawing Proposed New Action B, Previously Submitted in 981027 Application ML20204F1821999-03-0909 March 1999 Proposed Tech Specs,Adopting Changes in Frequency & Scope of Volumetric & Surface Exams Justified by W TR WCAP-14535A ML20155E4971998-10-28028 October 1998 Proposed Tech Specs 4.0.2 Re Applicability of 25% Surveillance Interval Extension Allowance ML20197G5521998-10-28028 October 1998 Rev 8 to Dbnps,Unit 1 Technical Requirements Manual ML20155E3231998-10-28028 October 1998 Proposed Tech Specs Revising Various Sections of 6.0, Administrative Controls, Including Relocation of 6.11 Contents to Plant Ufsar,Per NUREG-1430,Rev 1 ML20155D7791998-10-27027 October 1998 Proposed Tech Specs Relocating TS SR 4.6.5.1.d.4 Re Evs Negative Pressure Testing to TS 3/4.6.5.2,deleting TS Definition 1.24 & Making Related Changes Associated with Deletion of Subject Definition ML20155D8521998-10-27027 October 1998 Proposed Tech Specs Revising SRs 4.8.2.3.2.d,4.8.2.3.2.e, 4.8.2.3.2.f & Table 4.8-1 Re Testing of 125 Volt DC Station Batteries & Applicable TS Bases ML20155E0721998-10-27027 October 1998 Proposed Tech Specs Revising 3/4.3.1.1 Re RPS Instrumentation & 3/4.3.2.3 Re ARTS Instrumentation,To Provide Potential Reduction in Spurious Trip Rate for Potential Cost Savings in Excess of $50,000 ML20151W3071998-09-0808 September 1998 Proposed Tech Specs Permitting Use of Framatome Cogema Fuels M5 Advanced Alloy for Fuel Rod Cladding & Fuel Assembly Spacer Grids ML20151W2991998-09-0808 September 1998 Proposed Tech Specs Revising Section 3/4.7.6, Plant Systems - CREVS & Associated Bases ML20206D2721998-08-28028 August 1998 Rev 11,change 1 to Odcm ML20217P8351998-04-24024 April 1998 Proposed Tech Specs Clarifying Discussion of Margin Between RPS High Pressure Trip Setpoint & Lift Setting for Pressurizer Code Safety Valves ML20217P8811998-04-24024 April 1998 Proposed Tech Specs 3/4.3.1.1,3/4.3.2.1,3/4.3.2.2 & Associated Bases Relocating Tables of Response Time Limits to Plant USAR Technical Requirements Manual ML20217C4881998-03-20020 March 1998 Proposed Tech Specs SR 4.4.5.3.c.1,providing Greater Specificity as to Location of Addl Insps in Unaffected SG ML20217N4471998-02-27027 February 1998 Proposed Tech Specs Pages Provided to Modify Proposed New Action 3.7.6.1.b to Make More Consistent w/NUREG-1431 ML20203L1111998-02-26026 February 1998 Proposed Tech Specs Pages Re Amend to License NPF-3 Involving Incorporation of New Repair Roll Process for SG Tubes W/Defects in Upper Tube Sheet ML20197J2621997-12-23023 December 1997 Proposed Tech Specs Pages Re Changes to TS Definition 1.2, TS 3/4/9.5 & New TS 3.0.6 & Associated Bases.Ts Index Rev to Reflect Change to TS 3/4.9.5,included ML20197J5971997-12-23023 December 1997 Proposed Tech Specs Pages,Revising TS Surveillance Requirements for ISI Requirements of Internal Auxiliary Feedwater Header,Header to Shroud Attachment Welds & External Header Thermal Sleeves ML20217M5601997-09-0505 September 1997 Rev 11.0 to Davis-Besse Odcm ML20217R2821997-08-26026 August 1997 Proposed Tech Specs,Clarifying LCO 3.6.1.3.a & Revising Surveillance Requirement 4.6.1.3.c ML20217R2871997-08-26026 August 1997 Proposed Tech Specs,Modifying TS 3.2.5 Action Statement to Require Power Reduction to Less than 5% of Rated Thermal Power within Four Hrs If RCS Flow Rate Is Less than Specified Limit for Greater than Two Hrs ML20217G5981997-07-29029 July 1997 Proposed Tech Specs 3/4.4.3 Re Safety Valves & Pilot Operated Relief valve-operating ML20141F1101997-06-24024 June 1997 Proposed Tech Specs,Deleting Requirements for Safety Features Actuation Sys Containment High Radiation Monitors ML20138C3261997-04-18018 April 1997 Proposed Tech Specs 3/4.7.6 Revising Limiting Condition for Operation to Include New Required Actions in Event That One or Both Channels of Radiation Monitoring Instrumentation Becomes Inoperable ML20138A6891997-04-18018 April 1997 Proposed Tech Specs 3/4.5.3.2.1 & 3/4.5.2 Modifying Presently Specified 18-month Surveillance Frequencies to New Specified Frequencies of Once Each 24-months ML20140D9481997-04-0909 April 1997 ODCM, Rev 10 ML20138M1281997-02-14014 February 1997 Proposed Tech Specs 3.5.2 Re Emergency Core Cooling Systems & 4.5.2.f Re Surveillance Requirements ML20134L0561997-02-13013 February 1997 Proposed Tech Specs Re Changes Made Concerning Decay Heat Removal Sys Valve ML20134F1811997-01-30030 January 1997 Proposed Tech Specs Re Possession & Use of SNM as Reactor Fuel ML20134D7621997-01-30030 January 1997 Proposed Tech Specs Revising SR Intervals from 18 to 24 Months Based on Results of DBNPS Instrument Drift Study & TS 2.2, Limiting Safety Sys Settings, Based on Results of Revised Framatome RPS Instrument String Error ML20134B0591997-01-20020 January 1997 Proposed Tech Specs 3/4.5.3 Re ECCS Subsystems ML20132B7031996-12-11011 December 1996 Proposed Tech Specs Revising TS Definitions,Instrumentation TS & ECCS TS for Conversion to 24 Month Fuel Cycle for License NPF-3 ML20134F1891996-10-28028 October 1996 Proposed Tech Specs 3/4.8 Re Electrical Power Systems ML20117P5311996-09-17017 September 1996 Proposed Tech Specs,Supporting Conversion of DBNPS from 18 Month to 24 Month Fuel Cycle ML20117N8531996-09-12012 September 1996 Proposed Tech Specs Re Reactivity Control Systems & Emergency Core Cooling Systems ML20117M2201996-09-0404 September 1996 Proposed Tech Specs 6.2.3,removing Specific Overtime Limits & Working Hours ML20116K2631996-08-0707 August 1996 Proposed Tech Specs Re Definitions,Applicability Bases, Containment Spray Sys & Containment Isolation Valve for Conversion to 24 Month Fuel Cycle ML20117K1911996-05-28028 May 1996 Proposed Tech Specs 3/4.3.1.1 - RPS Instrumentation & TS 3/4.3.2.3 - Anticipatory RTS Instrumentation Increasing Trip Device Test Interval ML20101M1921996-03-29029 March 1996 Proposed Tech Specs 3/4.6.4.4 - HPS,3/4.6.5.1 - Shield Building Evs & 3.4.7.6.1 - CREVS Re Changing Surveillance Requirements for Charcoal Filter Lab Testing to Revise Methodology Used to Determine Operability in ESF AHUs ML20101C6961996-03-0606 March 1996 Proposed Tech Specs,Allowing Deferment of SR 4.5.2.b for ECCS Flowpath Containing HPI Pump 1-2 Until 10th Refueling Outage,Scheduled to Begin 960408 ML20100E0101996-02-0505 February 1996 Proposed TS 3/4.3.2.1,Table 3.3-3,safety Features Actuation Sys Instrumentation,Reflecting Design & Actuation Logic of Plant Sequencers & Essential Bus Undervoltage Relays ML20107C3101995-12-21021 December 1995 Rev 9 to Odcm 1999-09-07
[Table view] |
Text
{{#Wiki_filter:- --- - . . . - . .
Docket Number 50-346 Licen'se Number NPF-3
%rta! Number 2037 ,
sttachment Page 5 v l
5.0 :ESIG'i FEATUDES 5.1 IITE '
EXCLUSION AREA asde6cd in lDCFA Sd 100, l 5.1. The exclusion area is 3sh;ar, cc, Tigure 5.' - '
l r
LOW FOPULATION ZONE i as c;eG neA in IDCFR Ikrf 100.
5.1.2 The low population zone isjsho'. r. or 9;urc 5.'-2.
T hMcal l'O' p c\eEO CA h*ge.ction I. :
SITE EDUNDARY ,
ppact { l ,h ns , ; ,
a 5.1. 3 The UNRESTRICTED AREA _an(SITE BOUNDARY /for radioactive licuid effluents T is 3r.cwn on Figure 5.1-3. The UNRESTRICTED AREA ano SITE BOUNDARY for radio-
%acti e gaseous effluents is shown on Figure 5.1-4. ,
i
- 5. 2 :JNTAINMENT CONF:3URATION
- 5. 2. '. The containment structure is compris?d of a steel containment vessel, i having the snape of a right circular cylinder with a hemispherical dome and I elli;:isodal bottom, surrounded by a reinforced concrete shield building. i 5.2.1.1 CONTAINMENT VESSEL
- 2. Nominal inside diameter = 130 feet.
Nominal inside height = 285.5 feet.
- . 6 Net free volume = 2.834 x 10 cubic feet, f Nominal thickness of vessel walls - 1 1/2 inches. i
- e. Nominal thickness of vessel dome - 13/15 inches.
T
- f. Nominal thickness of vessel bot ;om - 1 1/2 inches. i 5.2.'. 2 SHIELO BUILDING
- a. Minimum annular spr.ce = 4.5 feet.
- b. Annulus nominal volume = 678,700 cubic feet.
- c. Nominal outside height (measured from top of foundation base '
to the top of the dome) = 279.5 feet. i
- d. Nominal inside diameter ='139.25 feet.
- e. Cylinder wall minimum thickness = 2.5 feet.
-f. Dome minimum thickness = 2.0 feet.
- g. Dome inside radius = 125.29 feet.
92O92203:20 920911 PDR ADOCK 05000346 '
P PDR DAVIS-3 ESSE. UNIT 1 5-1 AmenomentNo.((
- > r -- =*
CJ r* O w J 7:3 - n o O e*-mx
*9 DJ "3 e O :T w tn es er e o2 =
- s c z c
~uaa
. er a er e cr o n e-o.
2 o n
v, c, oza ,
- W5 I r jp - - umw
-...e;.
x . . i o
,y r
. g. . ,
.:J gy, * . :..
p s r= ...
-; LAKE y-. . .. . . f '
- l c- .
P*
4 -8'
, . M AR.SH _ .
./
3, ERIE
- 2: e s s - , .
,/ e
-4
/. .-:.
. [+
. * %aj
. ,. . .* ni
~" .,,,"!. e (~
I y\
* ,,( _t ;.**,** -
.:.h.
-)
/y
_ _1 a g'__1, me.- .
s c --
.netm
- v e r IT)
D 9
/
- 2 A. d.-v :s de e s v.m s w., %,.
( { ** *..
t e
1 r j M ARSH , ,i.e. se. ,,,,,,,,,c.,,, , t,),g, ,
' ==
- 3. ~ f e o,m m
pc ,s : ,d.* .
y' a xx IO*.t* * . "" .
. a s-.e ,.d *?**..'.,
N s :d.f,.;;, a, . .
rrr<
x ri1"):
is s i i .- ~ ,
im .
.p s is a .,
. t.-
4 \ '
l - . ts - .-=s.-. - a E.,.
d t i- __ _ _ _ a. _ _ _ _ g . - - - - - _m u m - -
s, -{ ,,
E NCt t254040 arf A 90tJedOARY ,
- I /
,- ~
/ x
. % ,f'
' ' ~
~
a '
. fyh .. T OUSSA!N T RIVER -
4
( )( < -
.A i
i g
\ S H;ttHS S 18
(* AVf 5 96 $$5 fet)C1I AH Pt WWI H $I AINW
() i a(L Lt$Nm Aftf A Ro M
0 ,% "n o
O" l
P i
A
, , . . , . , , - . . . _ , ~ . . . _ - ---
l !
, notike t Number 50-346 )
5 -
1,icense Number NFF-3 1 j ,erial Number 2037 f Attachment _
. i l' age 7 f !
'%i ;
l 1 y y x
6 l ..
) l
~ , . ,
1 __._,_. >
1 I .
.y. '
5 J f..L - *
. t l t l
~, J i
' .' ~. ' ,, . . .', -l i l * .
) Q ' M. 1 l
~
, ' b hME '8 .i' 'i , k I
..,,' , im -
i i
- s i
,'> '4M ..
w <n a / .
q p [ .a, h1 I
.y -
r- - <
l ; t
- D t 1- f 1 W
,. C. W . b- i i .
( ,
$ i r
k u,W< _~' M,Yf[klI( -x ry 9, l.
1 '
i
. M.J 1 g 's.fm- ....Z F /
= -- ar- -
f,d s -
l -
b::.@.= T-il
~ ,. j
-t I i
- . ' l. 1 '#
i ' Y. M l .fh 21 ) .... ,. i / !
l
-h M 1A _
7: _
} .* '_ ; ,/ ;
,/ ,
/ i
.DELETL~D
' Ori;S-BE5SE NUCLEAR POWER STATON
}
LOW POPULATON ZONE i FK3URE 5.1- 2 CMis-BEssE UNIT 1 5-3 1
l -
i
-4 -- ,-.-~ - _ -- _ . _ . .
.. ---.,-,,...-.'ww --.
2 - ,
5 . *
, . Dockey Number 50-346 ;
} ' license Number NPF-3 serial Number 2037 1
Attachment NN- t I
Page B N l i ! l DCLEM D Ec e =
l
! "e b -
- EE 5
- O[ N i. see? ;
2,0 -m 5~ i
- z i Eh".
.cgr f
' ! .)st-. >
l-
'; ',4 I s !
j ;- 9' 1
, d
. 4
] ki 3 ;
+
' j -
_w r.tst <$
j a+
8 F , t c_
' Sc .
, , ,e ,a , clock w 4e.
~ J
. y. <t .
- i. : ;
i e *
, ; t t
i d.
g i ? j \
i$
q, 1, j
,I i
! ,s' 4 i k i d e
i A( h!i ; p 1 :
i
=j=
i N-J.'M,3 i i !
a i
b.
k'y. , 4 I /
./ l i
__ g
< v, f >- i.,,, m. .
- .D 4
,1 ;
I !
l f "
W "
. . ... .Q. 4, _.
\ \
I w a
=.
l;4 .
\ r- ~ 0l 7.3r4:-
p 7~ --
d' ,
t I ;
l l-j ',a i 3II ! 6\ M' ;
t i
t 4 s I
I p, .
*i i p M*I ai s
. se I ' d ;
l* a f I
( l
(
OM:34E33E. UNIT 1 5-9
[ j' i / !
Aaendment No. M ,((d ; j 1
I
nocket Number 50-346 :
l.icense Number !!PF-3 serial Number 203' g _
i g cttachment 1
;- v, i
rage 9 $ E- j i
! DELETED "
E
} " I
- ' E< d l 4
j 2W b ;
i 1 5 .8.$ w T !
w -
"h! j d
[-
1 N
$5 . !
l 2 .-
g I h !f li I l
i 1
[\
-l ?$
E c
/
l \'
L- I b
rd{.N.%-j{
/ !
kg j
e '( s. '
... t ig
- l. .
e we V ;
4 j
j
.i .-- -
^ w.
i
' q3 g j 'j - dockw3e 6 ,d.v*' i 4 '
? ii Y
1 l
., ! , s. .4 i (iI ,
.y ai
'., j Q:f 5 6, i ;
\
. -;,. . .k 1 y j i 1 i
i .
i 0,< j .
.e. ji u i
.I \xxi
. 4 q\j.3 I '
- s - l 1 j '
Ni L 4 i ) i j
L['
1 i
\Ut{hJ
.wg
, i
,1 I
=
f (I il..; ~J _k ..g to3 i- r:li i . !
g T'.rs) i 8
t i --
(
1 I
.i 4.<
- , e:.2
,.=3, y M>
u f l i' 1 Gj D g
J
,. A; j r
i tm A ,
g k= -
L
/ ei !
\h i
! I r, f ;
j
(
\ ,
lih!...
?* -
I 5.
!h I
t
[
Ia :
- u m- A DAY 15-BESSE, Uh!T 1 '
1 '5'-10
- Amendment"No.Sf,g
- - - - . . - - - - - - -~ u,, n , . , w -, ,,.,,.,,-y-g,.- - _
Docket Number 50-346 '
License Number NPF-3 Scrial Number 2037 Attachment rue w {
INFORMATION ONLY DEFINITIONS
,1.29 Deleted ,
;jPROCESS CONTROL PROGRAM 1
i'l.30 The PROCESS CONTROL PROGRAM (PCP) shall contain the current fonnulas, j sampling, analyses, tests, and determinations to be made to ensure that processing ano packaging of solid radioactive wastes based on demonstrated processing of actual or simulated wet solid wastes will be accomplished in such a way as to assure compliance with 10 CFR Parts 20, 61, and 71 State regulation 1, burial ground requirements, and other requirements governing tne disposal of solid radioactive waste.
l 1.31 Deleted l 0FFSITE DOSE CALCULATION MANUAL (00CM) l 1.32 The 0FFSITE ME CALCULATION MANUAL (0DCM) shall contain the methodology l
= i and parameters used in ne calculation af offsite doses resulting from radio-
; active gaseous and licuid effluents, in the calculation of gaseous and liquid effluent monitoring Alarm / Trip Setooints, ano in the conduct of the Environ-4 mental Radiological Monitoring Program. The ODCM shall also contain (1) the
' Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by Section 6.8.4 and (2) descriptions v# the information
, that should be included in the Annual Radiological Envirorsnental Operating l
and Semiannual Radioactive Effluent Release Reports rcquired by Specifications j 6.9.1.10 a 6.S.1.11.
t j '1. 33 Deleted I 4 i
' I l 1.34 i
Deleted Deleted ,
l l1.35 l.36 Deleted l
MEMBER (S) 0F THE PUBLIC 1.37 MEMBER (S) 0F THE PUBLIC shall include all persons who are not occupation-ally associated with the plant. This category does not include employees of ne utility, its contractors or vendors. Also exciuded from this category j are persons who enter the site to service equipment or to make deliveries.
This category does include persons who use portions of the site for recrea-tional, occupatioral or other purposes not associated with the plant l
SITE BOUNDARY 1.38 The SITE BOUNDARY shall be that line beyond which the land is neither owned, nor leased, nor otherwise controlled by tne licensee. v DAVIS-BESSE, UNIT 1 1-6a Amenoment No. 26,170 '
~~~ ~ ~~' ~~~ ~~~ "' ~
! Docket Number 50-346 I License Number NPF.3 4
. . serial, Number 2037 i Attachment i DEFINITIONS FOR INFORMATION '
UNRESTRINED AREA i
l' 1.39 An UNRESTRICTED AREA shall be any area at or beyond the SITE BOUCARY l
access to which is not cor, trolled by the licensee for pu. poses of protection ~ !
i of individuals from> exposure to radiation and radioactive matterials, or any !
! area withim the SliE. BOUNDARY. used: for residendalequarters or: for industri&s >
i commercial, institutional, and/or recreational. purposes. The definition of -
[
- UNRESTRICTEII AREA:usein implementing the Radiological . Effluent Technical .
l
.j Specifications has been. expanded over that:iml0e CFR.420.3(a)(17). The .
! UNRESTRICTED AREAt boundary may coincide witir the exclusiorr-(fenced) area- !
j i boundary, as defined in 10 CFR 100.3(a), but the. UNRESTRICTED AREA does not- !
1 include areas over wate.- bodies. The concept cf UNRESTRICTED AREAS, estab- , !
j lished at or beyond the SITE BOUNDARY, is utilized in the LIMITING CONDITIONS. '
! FOR OPERATION to keep levels of radioactive materials in liquid and gaseous -
effluents as low as is reasonably achievable,. pursuant to 1C CFR 50.36a.
j l>
} 1.40 Deleted 4
l
! CORE OPERATING LIMITS' REPORT
^
1.41 The CORE OPERATING LIMITS REPORT is the unit-specific. document that li provides core operating. limits for the current reload cycle. These. cycle-
- 4 specific core operating limits shal's be detennined for each reload cycle in i accordance with Specification 6.9.1.7. Plant operation within these core- ,
j operating limits is addressed in individual specifications.
l l-i i i- !
i .
i !
( >
- ,-- r i
i i r
4 t
i :
i I
l DAVIS-BESSE, UNIT 1- .1-6b Amendment No'. ; M.JM,170 :
s
1 Docket Number 50-346 License Number NPF-3 s'ecial liumber 2037 Attachment FOR !NFORMAT -
i
- Page 12 N 2 WILE RA0lVS .
! NNW NNE !
I !
i o
- i i
149* 0 i i
11 ;
- WNw ENE !
67* 30* l
, 33* 4 4* 0 ?
s e
! N O' 0 l t 62 19 0 E j l
10 1B*
\ 0 0 l
\
t WSW l
*\0 !
- _P !
0 - 0* l i
j SW 43 47 47 , 'SE i 1 ,-
s t
SS 8 1970 FDPULAtl0N SHO W
- INDICATES SEGNEXT SUBJECT [
' $ TO SEASONAL INCREASE DUf'NG r suuu!R 50NTVS i
! SEE Taol. 2.1-5 i I '
1 5 PERMANENT POPULATION PROJECTION
! ANNULI
- i. lELLS 1171 M 1110. M M
! 0-1 18 1 181 181 211 277 i
! 1-2 410 410 410 47 1 505 !
?
li TOTAL 591 591 591 EB2 733 I j- t i
- FOR SEONENT O!STRIBUTION IN FUTURE YEAR $ SEE Table 2.1-2 j j FOR SEASONAL INCREASE. IN RESIDENT POPUL All0N 00RINr ;UMER MONTHS SEE Taele 2.1-5 ,
1 -
i DAVIS BESSE NUCLEAR POWER STATION
- LOW POPULAT10N ZONE FIGURE 2.1 i.
REVISION 0 JULY M82 :
I Dxket Number 50-346 License Number NPF-3 4
; Seri l Number 2037 i Attachment I
- lage 13 FOR INFORMATION ONLY ;
i :
i !
N l, L.
n a
I y 5tTE 80thCARY
- - {
NW.
; . I l i
4
\. ..
.r _ _ _ _4
- e. .
. e '.m. - '
ph*,.,....
,=
.- *[ -JO'a '.'.$,,
- % ; ,gr, - y.............,'
;'2 . ,,
? s ... _. _
/,/
/ , 'c 7 *e s
J, =-(. .. _; _, - m.
" m i ,
M- - .j ,9,'/,.xsn -
~
ow - t H_/ 4' /$ : . ..flg.'.,,\.
I- ~
1 /y 9 Jc ..o*,/ ,,/. . S y.b f
2
/
/s ,
d y&
. .i
. 'g * *,s
]
- j
..- ~*
i
,/
c v. CD bg ** ,T fr ,4 ,
ro .uuuma 3
R '
t *.
" *- ^* ,.,,-
~
f l [ \ , fi@ . 8 - =- . . ~f 4, ,, l
- , \- .
Y,t.! , . . . .-
\;. 4 y P 4 v'- 1 ;
i
,o t A,9
_ _- ___..e48 m .. . . s, , +
x n g;. .' . ,- .
g* - t
*o .
,_m _
. ._,,_ - . _._ m ..,
' N t i-j
! \ -
m 1
g 19h l
(
I
\
\
- 4. ... n = ' .
l \ i
! \ <
[ .' >
i
\ s rouem exa ,
l m, i
y .
1 -.
! 1 d,
\ .
i
, 'I I
DAVIS-BESSE NUCLEAR POWER STATION SITE ARRAM.;EMENT :
l FIGURE 2.1 3 i l >
l.
(. +
1
' REVISION I I JULY 1983.
~
wms-- =*}}