3F0692-19, Forwards Suppl 2 to BAW-2127, Pressurizer Surge Line Thermal Stratification for B&W 177-FA Nuclear Plants,Summary Rept Fatigue Stress Analysis of Surge Line Elbows, to Address Util Actions to Comply W/Bulletin

From kanterella
(Redirected from ML20101H411)
Jump to navigation Jump to search
Forwards Suppl 2 to BAW-2127, Pressurizer Surge Line Thermal Stratification for B&W 177-FA Nuclear Plants,Summary Rept Fatigue Stress Analysis of Surge Line Elbows, to Address Util Actions to Comply W/Bulletin
ML20101H411
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 06/25/1992
From: Beard P
FLORIDA POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20101H414 List:
References
3F0692-19, 3F692-19, IEB-88-011, IEB-88-11, NUDOCS 9206290334
Download: ML20101H411 (3)


Text

--_m._.__.___

o e* * .

g e.

8 A e ta s c+

00 e...e Florida Power '

crhetal t U lt 3 Docket No. s0-302 June 25, 1992 3F0592-19 U. S. Nuclean Regulatory Commission I g- Attn:- Document Control Desk P Washington, D. C. 20555

Subject:

Bulletin 88-11: Pressurizer Surge Line Thermal Stratification

References:

A. NRC to FPC letter 3N0292-09, dated February 21, 1992 B. B&W Owners Group letter 0G-1048 to NRC, dated June 11, 1992 -

Dear Sir:

Florida Power Corporation (FPC) is submitting this letter in response to the NRC s~.

request in Reference A. 1he NRC requested FPC to provide verification of the plant-specific applicab;11ty of the B&W Owners Group (BWOG) program and results to resolve the pressurizer surge line thermal stratification issue for Crystal River Unit 3 (CR-3).

- The BWOG submitted Supplement 2 to BAW-2127, " Summary Report, Fatigue Stress Analysis of the Surge Line Elbows" in Reference B. This supplement resolves the one outstanding issue of surge line elbow stresses in the BWOG analyses for the Bulletin 88-11. The BWOG thermal stratification fatigue stress analyses are based upon:

1. no interference of the surge line with any other structure,
2. surge line movements within the travel range of each snubber, 3.- ~ surge.line movements within the travel _ range of each hanger._and l

l 4. branch moments at the surge -line drain nozzle connection within l their respective maximum allowables (for Deadweight, Operating Basis l Earthquake, and thermal stratification).

t L

200.iOS 1

\ 9206290334 920625 PDR

\.

O ADock 05000302 PDR A Florida Progress Company b3.fd I


- - - - - - - ~~~~~~~~~~~~~~

Y/

1 U. S. Nuclear Regulatory Commission 3F0692-19 Page 2 The generation of the revised Design Basis transients (for future events) is based on the incorporation of operational guidelines which:

5. limit the pressurizer to RCS temperature difference during plant heatups and cooldowns (imposed with pressure / temperature limits),

and

6. prevent surveillance tests that cause rapid additions to the RCS from being performed with a pressurizer to RCS temperature difference greater than 220*F.

A walkdown of the LR-3 pressurizer surge line was performed to verify item 1.

FPC has calculations available which document Items 2, 3, and 4. Item 5 is controlled by Plant Operating Procedure OP 1038, "Heatup/Cooldown And Operating Curve.s," and Technical Specification 3/4.4.9, RCS Pressure / Temperature Limits.

FPC has reviewed CR-3 surveillance procedures and determined that these procedures will assure that item 6 is met.

The conclusions of BAW-2127 and BAW-2127 Supplement 2 are applicable to CR-3.

A copy of BAW-2127 Supplement 2 is submitted as an attachment to this letter. ,

This submittal completes FPC's actions required by Bulletin 88-11 and Reference A.

Sincerely, to

.M Beard, Jr.

Senior Vice President Nuclear Operations PMB/JWT Attachments xc: Regional Administrator, Region 11 Senior Resident inspector NRR Project Manager Mr. A. W. Robinson, BWOG (w/o att)

0- < .

e .

U. S. Nuclear Regulatory Commission 3F0692-19 Page 3 STATE OF FLORIDA COUNTY OF CITRUS P. M. Beard, Jr. states that he is the Senior Vice President, Nuclear Operations for Florida Power Corporation; that he is authorized on the part of said company to sign and file with the Nuclear Regulatory Commission the information attached hereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information, and belief.

{

/ s&t / ~

P. M. Beard, Jr.

Senior Vice President Nuclear Operations Subscribed and sworn to be re me, a Notary Public in and for the State and County above named, this ay of June, 1992.

?

2A& th, Notary Public Notary Public, State Af.,[}ggjjibAt oWQb .i t.,,.