Supplemental Info to Semiannual Radioactive Effluent Release Rept for Jan-June 1990,consisting of Description of Changes to Rev 3 of Process Control Program
ML20091A113
Person / Time
Site: Grand Gulf 
Issue date: 06/30/1990
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20091A109 List:
References
NUDOCS 9105140286
Download: ML20091A113 (7)


Text

.

i L

ATTACHMENT i=

EXPLANATION OF CHANGES IN REVISION 3 0F GGNS PCP Revision 3 of the Grand Gulf Process Control Program (PCP) was performed at the request of statinn Radiation Control staff and Quality Programs staff to better define some terms used, and to update the document with some new methods for processing radioactive waste for burial.

Those organizations, along with Radiological & Environmental Services, determined that the changes did not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes, because most of the changes are editorial in nature, and, although some new processing options are included, none of the changes af fect the current methods for processing radioactive vaste for burial.

It was determined by Radiological & Environmental Services staff, Grand Gulf Radiation Control staff, and the Grand Gulf Plant safety Review Committee that the changes in revision 3 of the PCP would not degrade any station safety systems or reduce the margin-of safety of any station operating parameters.

Detailed information to support the rationale for the changes and the determination that the changes did not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes is provided below.

TABLE OF CONTENTS o

Item E - deleted section on " Packaging Requirements" since the subject is addressed in other parts of the PCP, and is controlled by approved station procedures (as_ described in Section B) which include pertinent regulatory recuirements.

The inclusion of specific packaging requirements in the PCP is redundant and unnecessary.

The- ' ore, conformance to existing criteria for solid l

wastes is not reduced by the change.

l I

LIST OF EFFECTIVE PAGES o

changed revision number A.

Introduction o

Paragraph 1,-Sentence 1 - editorial change: added the word

" radioactive" to describe waste addressed by the PCP, as opposed to the other kinds of waste generated at GGNS.

Added the words "e.g.

oil, oily sludge, EHC fluid, glycol" to give examples of the kinds of 11gulds being addressed by-the PCP.

Deleted the word " oil" from the examples of wet solids, since most oils used at the station are liquids.

These editorial changes are for clarification, and do not change or. reduce conformance to existing criteria, o.

Paragraph-1, Sentence added this new sentence to describe a rew method of preparing some radioactive wastes for burial, namely volume reduction at an offsite vendor facility.

The end product of volume reduction (e.g. Incineration) must still conform to existing-standards for_ solid waste disposal.

PCPREV3.GMM/JRSFLR-1 9105140286 910507 PDR ADOCK 05000416 PDR l-R.

o Paragraph 1, Sentence 3 - editorial change: relocated this sentence from Paragraph 2 to maintain subject consistency in Paragraph 2.

o Paragraph 2, Sentence 1 - editorial change: deleted the words " Grand Gulf Nuclear Station" since the acronym "GGNS" is defined in Paragraph 1, Sentence 3.

o Paragraph 3, Sentence 1 - editorial changes relocated this sentence from Paragraph 1 to maintain subject consistency in Paragraph 3 concerning the processing of wet solids.

Added the words " powdered and bead" to describe the types of resins chich are processed for burial.

Added the word " vitrification" to include a new technology for preparation of resins for burial, which is expected to be in use within a few years.

Vitrification (or glassification) could solidify resins in a nmch more stable matrix than the current dewatering or solidification, and would significantly reduce their burial volume.

As with existing processing methods (e.g. solidification) this process must either have an approved NRC Topical Report, or the PSRC must ensure the contractor's final waste form for burial complies with applicable regulations.

Therefore, there is no reduction in conformance with existing criteria.

o Paragraph 3 Sentence 3 - editorial change: deleted the word

" polyethylene" since that is not the only type of flIC (high integrity container) used at GGNS.

Deleted the words " Dewatering is performed" from the former Sentence 3 and combined the words "according to vendor's procedures" with the new Sentence 3 to eliminate unnecessary words, o

Paragraph 3 Sentence 4 - added this new centence to describe new options for processing resins for disposal, i.e. by vitrification at a vendor facility or by use as loose fill material in packages of supercompacted waste.

(see discussion of Paragraph 3, Sentence 1 above.)

o Paragraph 3, Sentence 5 - added the words "for dewatering, solidification or vitrification" to define which contractor PCP topical reports must be approved by the NRC to ensure compliance with 10CFR20, 10CFR61, and 10CFR71.

Changed " accepted" to

" approved" to more appropriately describe the results of NRC review of a topical report.

o Paragraph 4 Sencence 1 - reworded this sentence to describe new disposal option for radioactive liquids, i.e.

incineration.

Changed the word "will" to "may" to clarify that these are options for disposal of radioactive liquids.

As with existing processing methods (e.g. solidification) this process must either have an approved NRC Topical Report, or the PSRC must ensure the contractor's final waste form for burial complies with applicable regulations. Therefore, there is no reduction in conformance with existing criteria.

PCPREV3,GMM/JRSFLR-2

.~ - - -. ~ _ _. ~ -

4 Included the words "EllC fluid, glycol" to add these materials to the definition sf " radioactive 11gulds", since these wastes may be generated in the future.

o Paragraph 4 Sentence 2 - editorial change: added this sentence to clarify that solidification is an option for disposal of radioactive liquids and wet solids, vs incineration.

o Paragraph 4 Sentence 3 - editorial changes reworded this sentence to clarify that there are other options for solidification of radioactive 11gulds and wet solids besides onsite solidification, i.e. offsite solidification at a licensed vendor facility.

o Paragraph 4.. Sentence 4 - added the words "for incineration or solidification" to define which contractor topical reports must be approved by the NRC to ensure compliance with 10CFR20, 10CFR61, and 10CFR71.

Changed the word " accepted" to " approved" to more appropriately describe the results of NRC review of a topical report.

These changes stipulate that compliance with existing criteria for solid wastes must be maintained for these processes.

Deleted _the words "U.S. Nuclear Regulatory Commission" and substituted "NRC" since the acronym "NRC" is defined in Paragraph 3.

o Paragraph 5 - added this new paragraph to describe the requirements for packaging and shipping of radioactive waste to an offsite vendor facility for incineration, solidification or vitrification.

The final _ form of the waste for-burial must still conform to existing standards,_whether these processes are performed onsite or at an

- offsite vendor facility.

Included the.stipulat'lon that the offsite processing facility will

.take title to the waste, and ensure that the waste meets all applicable requirements for disposal.

This stipulation means that the vendor is_ responsible thereafter for the ultimate disposition of the waste, and for ensuring that the final form for burial conforms to existing criteria for solid wastes.

B.

Administrative Controls o

Paragraph 1 Sentence 1 - editorial changes relocated this sentence from Section A, Paragraph 1 since the subject (compliance with-federal and state regulations and disposal site criteria) concerns administrative > controls, o

Paragraph 1 Sentence 2 - added_this sentence to state that adherence;to established procedures for processing radioactive waste-for burial is required, whether the procedures are Grand Gulf station procedures or contractor procedures.

This'will help ensure that appropriate controls are in effect for processing the waste while it is under Grand Gulf control.

o Paragraph 2 Sentence 1 and 2 - editorial change: joined these sentences together (formerly in separate paragraphs) into one paragraph, since they both pertain to the intent and use of written

' instructions.

PCPREV35GMM/JRSFLR-3

- ~

~-.----

~

Paragraph 2.' Sentence 2 - editorial change: changed the word o

" Directives" to " Procedures" since " Directives" usually means a higher tier set of instructions than implementing procedures, to which this sentence refers, o

Paragraph 3, Sentence 1 - editorial changes reworded this sentence to add PSRC on approval cycle for contractor procedures, consistent with Section A, Paragraphs 3 and 4.

Added the words "for onsite processing" to specify which procedures are to be reviewed.

Deleted

" Chemistry /" from the-title " Chemistry / Radiation Control Section" to reflect the current organization title, o

Paragraph 3, Sentence 2 - changed the word " screened" to " approved" to correctly state the meaning that changes'to contractors' procedures for onsite radioactive waste processing will be approved not just screened _- by the Radwaste Operations Section and Radiation Control.

Deleted " Chemistry /" from the title " Chemistry / Radiation Control" to reflect the current organization title.

Changed the word " forwarded" to " Screened for forwarding" so that procedure changes of a minor nature (i.e. administrative changes) l will not necessarily have to be approved by the PSRC; instead, the

)

Radwaste Operations and Radiation Control sections will review and sparove minor administrative changes.

Since.any changes involving i

process controls or monitoring, media formulation or proportions, or determination of acceptable final product for disposal will be reviewed and accepted by the PSRC there is no reduction in conformance to existing criteria.

Changed the phrase "to_PSRC for review" to "to PSRC for review and approval" to reflect the requirement for-PSRC approval of significant changes in contractors' procedures.

o Paragraph 3. Sentence 3 - program enhancements added this new sentence, per Quality Programs'. request, to require reviews of contractors' procedures to be documented and maintained as QA

records, o

Paragraph 4, Sentence 1 - reworded this sentence, as requested by Radiation Control staff. to delete specific references to types of information to be documented.on each batch of-processed waste; i.e.

" source of waste, date processed, processing parameters, physical and' chemical characteristics, dose rates, contam' nation levels and other".

This information is already required by approved Radiation Control or contractor procedures to be documented on each batch of-

-processed: waste.

The procedures are controlled in accordance with

-Section B of the PCP; therefore, there ir no reduction in conformance with existing criteria.

o.

Paragraph 4, Sentence 3 - program enhancement: added this new sentence, per Quality Program's request, to require-that information on each batch of processed waste be maintained as QA records.

PCPREV3.GMM/JRSFLR-4 a.

C.

Waste Streams o

Editorial changes revised the 11st of waste stream names to clarify the source of wastes to be processed.

These are changes in name only.

No waste streams were deleted from the sources of wastes to be processed.

o Added " Contaminated Waste 011" as a waste stream, since this type of waste has been generated in the past and more is expected in the future. The addition of this waste stream maintains conformance to existing criteria, o

Paragraph 2, Sentence 2 - added this new sentence to include the contingency for processing wastes which are not part of normal radioactive waste streams, but which are generated from time to time, e.g. EHC fluid and glycol.

D.

Conditioning of Waste and Sampling for Verification of Solidirication o

Paragraph 1, Sentence.1 program enhancement added the words

" container in a" for clarity to specify how many samples must be taken to verify solidification of each batch of 11guld waste.

This actually increases the number of samples from one in every tenth batch of waste to one in every tenth container in a batch (a batch could have many containers that get solidified, e.g. drums).

This change was made at the request of Radiation Control staff, o

Paragraph 1, Sentence 2 - editorial change: deleted " Chemistry /"

from the title " Chemistry / Radiation Control Superintendent" to reflect the current title, NOTE - added this note to define a " batch" for clarification as o

requested by Radiation Control staff and Quality Programs staff.

o Paragraph 2, item d) - replaced the words "most stable billet" with

" maximum practical compressive strength" as requested by Radiation Control staff and Quality Programs staff.

Those words were taken from the NRC Branch Technical Position on Waste Form (5/11/83),

section C2.b.

This changes the intent of the statement so that addition of unnecessarily large proportions of solidification media are no longer required, as explained in the note following the statement.

o NOTE - added this note to clarify the objective of testing the solidified matrix for stability.

The words were taken from the NRC Branch Technical Position on Waste Form (5/11/83), section C2.b.

The range of stability could theoretically extend from the " minimum acceptable compressive strength" of 50 psi to the "most etable billet" which would be 100% solidification media and 0% waste material.

The determination to be made for each batch of waste to be solidified is: how much higher than the minimum acceptable compressive strength should we seek, realizing that bigher strengths l

will require more solidification media? That determination will be PCPREV3.GMM/JRSFLR-5

j i

made by Radiation Control staff during the solidification process and will be based.on the cost-effectiveness of the proportions of 1

solidification media, while ensuring that the final product for l

disposal' conforms to existing criteria for solid wastes, i

l l

o Paragraph 2, item e) - added the words "an acceptable" to qualify l

" solidified billet" as requested by Radiation Control staff and Quality Programs staff. This is consistent with the intent of the j

above NOTE concerning the stability of the final solidified material.

1 o

Paragraph 3, Sentence 1 - editorial changer deleted the words "a i

l representative sample will be obtained and" to remove unnecessary d

i.

words.- The intent, of course is to obtain representative samples of j

miscellaneous wastes to ensure they are processed to the same quality standards as normal waste streams.

But this paragraph also l

references the preceding paragraph on sampling, which includes a l

narrow definition of a " batch", i.e. that it is a homogenous mixture, thus representative sampling is ensured.

o Paragraph 4 Sentence 1 - program enhancement: cdded the words

" producing the maximum practical compressive strengths" as requested

.by Quality Programs staff.

This is to ensure the final solidified L

material meets the standards agreed to by the contractor.

o Paragraph 5, Sentence 1 - program er.hancement: added the words

" producing the maximum practical compressive strengths" as requested by Quality Programs staff.

This is to ensure that the entire batch of waste material is of uniform quality and meets applicable standards.

1 E.

Packaging Requitements o

Deleted this section, as requested by Radiation Control staff, because requirements for packaging radioactive waste for transport and burial are specified in applicable regulations and are cutlined in approved Radiation Control procedures.

(See discussion of changes under " Table of Contents".)

F.

Sampling for Verification of Curie Content o

Paragraph 1, Sentence 1 - program enhancement added the words

" container in a" to clarify how many isotopic analyses must be performed on a batch of waste, as rec'ested by Radiation Control staff..This is consistent with the requircment in Section D on sampling for verification of solidification.

(See Section D, Paragraph 1. Sentence 1).

o Paragraph 1, Sentence 2 - editorial change deleted " Chemistry /"

from the title " Chemistry / Radiation Control Superintendent" to reflect the current title, o

Paragraph 2, Sentence 1 - editorial change: retained this sentence from the former Section E, Paragraph 3 because it specifies why isotopic and curie content must be determined when packaging waste for burial.

PCPREV3.GMM/JRSFLR-6

4, 4~'9

, e-j --

4 I

o Paragraph 2, Sentence 2 - editorial change: changed the term " dose rate conversion" to " dose-rate-to-curie conversion" to correctly describe how an-estimate of the radioactivity content of a package l-may be determined.

t j'

t 3

m i

d f

Y l

f f

i i '

i i

f I

t 4

i n

PCPREV3.GMM/JRSFLR-7

....