._

f l'

&/

J

~

NSP l

l i

l NORTHERN STATES POWER COMPANY M IN N E A PO L.a s. M IN N E SOTA S S401 June 7, 1976

- x

.x s -

U N

'\\

D Dj[5

,.; ~,

Mr Victor Stello, Director i~h % jJg. y, T.

Division of Operating Reactors (y';3 cu, ;.,7;f

'(

U S Nuclear Regulatory Commission

,?/

i Washington, DC 20555

1.,,,

s

'Q@,

Dear Mr Stello:

MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 I

Response to 5/20/76 Inquiry Concerning LPCI Design

)

i Your May 20, 1976 letter identified a potential design deficiency related to LPCI pump cavitation and motor overload. Monticello has the Loop Selection Logic System and does not have the LPCI modification. Therefore, item a j

of your letter is applicable and item b.is not.

The Monticello piping layout and pump data have been reviewed. At runout

[

flow the NPSH requirements of the pump are met.

The pump characteristic l

curves show that at high flows, the brake horsepower and motor current de-A crease.

Therefore, the Monticello LPCI pumps are not subject to damage due to cavitation or motor overload in the runout condition.

(

Yours Very truly, L 0 Mayer, PE bb1 Manager, Nuclear Support Services LQ4/MHV/ deb cc: J G Keppler C Charnoff i

MPCA I

Attn:

J W Ferman 8312050151 780426 PDR ADOCK 05000263 g

PDR COPY SENT REGION A_

._.