CALCULATION / PROBLEM COVER SHEET Calculation / Problem No: 1040-001-031

Title:

Display Instrumentation-Referenced in LCC A/HELB Procedures 33 Client: Toledo Edison CompanV Project: Davis-Basse Unit 1 I&E Bulletin 79-01B Job No: 1040-001-671 Equipment Qualification Ds:Ign input /Reforences:

Design Inputs are outlined in the Cover Report.

Accumptions:

Assumptions are outlined in the Cover Report.

Msthod:

'{

}

Methods are outlined in the Cover Report.

l l

l l

R: marks:

l l

EDS Nuclear Report No. 02-1040-10'/6.

REV. NO.

REVISION

' APPROVED DATE s

o S

GE+'22M L MAAlt/AL i=Y/S / 0 N S Uk 01# Sk kb l

/

f 1

l F

8312200305 931129 I

PDR ADOCK 05000 i

N N

s x,

\\

Fccilith,s, ' Davic-BeEOa Unit 1 MASTER M ST Index Nos b 36-001 Docket 50-346 HARSH ENVIRONMENT Rev.:

2 DISPLAY INSTRUMENTATION REFERENCED IN LOCA/HELB PROCEDURES Prapared by:

Dater /

D Checked by:

3 ~r 1 v,h.#

Date:

3 l

l l

l l

LOCATION l

l l

l l

l l

Inside l

Outside l

l l Worksheet l l

Plant l

l Primary l

Primary l

l l

Index No.

l Rev. lID Number l Generic Name l Containment l Containment l REMARKS l

l l

l 1

1 I,

I l

l 303H-008 l

0 lAT1999 l Boron Meter l

l Rm. 208 l

l l 303H-009 l

0 lFI2638

{ Component Cooling to Seal Water Cooler l

l Rm. 208 l

l l

l l

l Flow Indicator

]

l l

l l 303H-009 l

0 lFI2642 l Component Cooling to Seal Water Cooler l

l Rm. 208 l

l l

l l

l Flow Indicator l

l l

l l 303H-010 l 0 lFI4999 l Auxiliary Spray Flow (Local) Indicator l

l Rm. 227 l

l l 303H-Oll l 0 lFTMU7 l Letdown Flow Transmitter l

l Rm. 208 l

l l 303H-012

'l 0

lFmul9 l Seal Injection Flow Transmitter l

l Rs. 208 l

l l 303H-013 l

0 lFTMU41 l Boric Acid Flow Transmitter l

l Rm. 227 l

l l 303H-014 l

0 lFMU60A l Controlled Bleed Off Flow Transmitter l Containment l l

l l 303H-014 l 0 l F'DtU60B l Controlled Bleed Off Flow Transmitter l Containment l l

l l 303H-014 l

0 l PDtU60C l Controlled Bleed Off Flow Transmitter l Containment l l

l l 303H-014 l 0 lFTMU60D l Controlled Bleed Off Flow Transmitter l Containment l l

l l 303H-015 l 0 l Deleted l

l l

l l

l 303H-016 l 0 lLT1546A l Sump Level Transmitter l Containment l l

l l 303H-016 l 0 lLT1546B l Sump Level Transmitter l Containment l l

l l 303H-017 l 0 lLT225 l PRZR Quench Tank Level l Containment l l

l l 303H-018 l 0 lLTCF3Al l Core Flood Tank Level Transmitter l Containment l l

l l 303H-018 l 0 lLTCF3A2 l Core Flood Tank Level Transmitter l Containment l l

l l 303H-018 l 0 lLTCF3B1 l Core Flood Tank Level Transmitter l Containment l l

l l 303H-018 l

0 lLTCF3B2 l Core Flood Tank Level Transmitter l Containment l l

l l 303H-019 l

0 lPT224 l Pressurizer Quench Tank Pressure l Containment l l

l l

l l

l Transmitter l

l l

l l 303H-020 l

0 lPT412 l Pressurizer Pressure Transmitter l Containment l l

l l 303H-021 l 0 lPT616 l Main Feed Pressure Transmitter l Containment l l

l l 303H-021 l

0 lPT618 l Main Feed Pressure Transmitter l Containment l l

l l 303H-022 l 0 lPTMU26 l Seal Injection Pressure Transmitter l

l Rm. 303 l

l l 303H-023 l

0 lTE1356 l Containment Temperature Element l Containment l l

l l 303H-023 l

0 lTE1357 l Containment Temperature Element l Containment l l

l l 303H-023 l

0 lTE1358 l Containment Temperature Element l Containment l l

l l

l l

l l

l l

l

C O

)

j Fccility, Devic-Becco Unit 1 MASTEb41ST Index NotD 53M-002 Dockst 50-346 HARSH ENVIRONMENT Rev.:

2 j

DISPIAY INSTRUMENTATION j

REFERENCED IN LOCA/HELB PROCEDURES 2

Prepared by:

Dates /

D Checked by:

hih J. J Date:

  • '3 l

l l

l l

LOCATION l

~l I

l l

l l

l Inside l

Outside l

l j

l Worksheet l l

Plant l

l Primary l

Primary l

l i

l Index No.

l Rev.

ID Number l Generic Name l Containment l Containment l REMARKS l

l l

l l

l 1

I i

l 303H-024 l 0 lTE4902 l Injection Nozzle Temperature l Containment l l

l j

l 303H-025 l 0 lTE4998 l PORY Loop Seal Temperature l Containment l l

l J

l 303H-026 l

0 lTE596 l Auxiliary Feed Nozzle Temperature Element l Containment l l

l

)

l 303H-027 l

0 lTE605 l Main Feed Nozzle Temperature Element l Containment l l

l l

l 303H-027 l

0 lTE%6 l Main Feed Nozzle Temperature Element l Containment l l

l l

l l 303H-027 l

0 lTE969 l Auxiliary Feed Nozzle Temperature Element l Containment l l

l l

l 303H-028 l

0 lTERCl2-1 l PORY Discharge Heat Trace Temperature l Containment l l

l j

l l

l l Element l

l l

l

{

l 303H-029 l 0 lTERC15-1 l Pressurizer Temperature Element l Containment l l

l

^

l 303H-030 l

0 lTERC9 l PRZR Spray Water Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESPilAl l SG Downcomer Temperature Element l Containment l l

l I

l l 303H-031 l 0 lTESPllA2 l SG Downcomer Temperature Element l Containment l l

l 1

l 303H-031 l 0 lTESPilA3 l OTSG Shell Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESPilA4 l OTSG Shell Temperature Element l Containment l l

l l

l 303H-031 l

0 lTESPilA5 l OTSG Shell Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESPilB1 l SG Downconer Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESPilB2 l SG Downconer Temperature Element l Containment l l

l l 303H-031 l

0 lTESPllB3 l OTSG Shell Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESPilB4 l OTSG Shell Temperature Element l Containment l l

l l

l 303H-031 l 0 lTESP11B5 l OTSG Shell Temperature Element l Containment l l

l l

I l 303H-032 l 0 lZE8901 l Reactor Coolant Pump Vibration Monitoring l Containment l l

l

[

l l

l l Equipment l

l l

l l 303H-032 l 0 lZE8902 l Reactor Coolant Pump Vibration Monitoring l ' Containment l l

l l

}

l l

l l Equipment l

l l

l l

}

l 303H-032 l 0 lZE8903 l Reactor Coolant Pump Vibration Monitoring l Containment l l

l l

l l

l l

Equipment l

l l

l l 303H-032 l

0 lZE8904 l Reactor Coolant Pump Vibration Monitoring l Containment l l

l l

l l

l l Equipment l

l l

l

}

l 303H-033 l

2 lPTCF4A1 l Core Flood Tank Pressure l Containment l l

l l

l 303H-034 l 2 lPTCF4A2 l Core Flood Tank Pressure l Containment l l

l i

l l

1 l

l l

1 I

i 1

i 1

l y-g y..

y

+-

~

\\

r Ftcility: D via-Bescs Unit 1 MASTER LIST Index N3: 303M-003

]

Docket:

50-346 HARSH ENVIRONNENT Rev.:

2 9

DISPLAY INSTRUNENTATION j

REFERENCED IN LOCA/HELB PROCEDURES Prepared by:

b 8"

[

Date:

Checked by: _hl #

Date: N /j //3 4

l l

l l

l LOCATION l

l l

l l

l l

Inside l

Outside l

l i Worksheet l l Plant l

l Primary l

Primary l

l i

l Index No.

I Rev. lID Number l Generic Name l Containment l Containment l REMARKS l

l l

l l

l 1

I I

I l 303H-03Q l

2 lPTCF481 l Core Flood Tank Pressure l Containment l l

l l 303H-036 l

2 lPTCF4B2 l Core Flood Tank Pressure l Containment l l

l l

l 2 lFTDH2A l Decay Heat Removal Flow Transmitter l

l Rm. 236 l

See 3.01 l

l l

2 IFTDH2B l Decay Heat Removal Flow Transmitter i

I Rs. 105 i

See 3.01 I

l l 2 IFTHP3A l HPI Flow Transmitter l

l Rs. 236 l

See 3.01 l

f I

l 2

lFTHP3B l HPI Flow Transmitter l

l Rs. 236 i

See 3.01 l

i l

2 lFTHP3C l HPI Flow Transmitter l

l Rs. 208 l

See 3.01 l

j l

l 2

lFTHP3D l HPI Flow Transmitter l

I Rs. 208 l

See 3.01 l

l l

l 2

lFTRCIAl l RCS Flow Transmitter l Containment i I

See 2.18 l

l l

l 2 lFTRCIA2 i RCS Flow Transmitter l Containment l l

See 2.18 l

{

l l

i 2

lFTRCIA3 i RCS Flow Transmitter l Containment l l

See 2.18 l

i l

l 2

IFTRCIA4 l RCS Flow Transmitter l Containment l l

See 2.18 l

l 2

l l

2 IFTRCIB1 l RCS Flow Transmitter l Containment l l

See 2.18 i

j l

i 2

IFTRCIB2 l RCS Flow Transmitter l Containment l l

See 2.18 l

i l

l 2

lFTRCIB3 l RCS Flow Transmitter l Containment l l

See 2.18 1

{

l 1

2 IFTRClB4 l RCS Flow Transmitter l Containment l l

See 2.18 l

j l

l 2

lLTRCl4-1 l Pressurizer Level Transmitter l Containment l l

See 3.01 l

1 l

l 2

lLTRCl4-3 l Pressurizer Level Transmitter l containment l l

See 3.01 l

f I

l 2 lLTSP9A3 l S/G Level Transmitter l Containment l l

See 3.01 l

}

l l 2 lLTSP9A4 l S/G Level Transmitter l Containment l l

See 3.01 1

l l

2 ILTSP983 l S/G Level Transmitter l Containment l l

See 3.01 l

i l

l 2 lLTSP984 l S/G Level Transmitter l Containment l l

See 3.01 l

l l

l 2 lPT2001 l Containment Pressure Transmitter l

l Rs. 501 i

See 2.19 l

l l

l 2 lPT2002 l Containment Pressure Transmitter l

l Rs. 500 l

See 2.19 l

f I

I 2

lPT2003 i Containment Pressure Transmitter l

l Rm. 426 l

See 2.19 l

[

j l

l 2

lPTRC2A3 l RCS Pressure Transmitter l Containment l l

See 2.19 i

1 I

2 lPTRC2A4 l RCS Pressure Transmitter l Containment l I

See 2.19 l

j l

l 2

lPTRC283 l RCS Pressure Transmitter l Containment l l

See 2.19 l

l l

2 lPTRC2B4 l RCS Pressure Transmitter i Containment l l

See 2.19 l

}

l I

l l

I I

l I

i

C v

Ficilit i Davis-Bes2e Unit 1 MASTER LIST Index D3: 303M-004 Docket:

50-346 HARSH ENVIRONMENT Rev.:

2 DISPLAY INSTRUNENTATION REFERENCED IN LOCA/HELB PROCEDURES

/!MJ7 Ptspared by:

M Date:

Chscked by:

A#dd Date: ///g//1 l

l l

l l

LOCATION I

l l

l l

l l

Inside i

Outside l

l l Worksheet l l

Plant l

l Primary l

Primary l

l l

Index No.

I Rev. IID Number I Ceneric Name l Containment I Containment i REMARKS l

1 1

I I

I I

I l

l l

2 lPTSP12Al l Steam Line Pressure Transmitter i Containment l l

See 3.01 1

1 I

2 lPTSP12A2 l Steam Line Pressure Transmitter l Containment l l

See 3.01 1

I l

2 lPTSP12B1 l Steam Line Pressure Transmitter i Containment l l

See 3.01 l

l l

2 IPTSP12B2 i Steam Line Pressure Transmitter l Containment l l

See 3.01 l

i l

l 2

ITERC3A2 i RCS Temperature (Hot Leg) Element l Containment i I

See 2.18 l

l l

2 ITERC3B2 i RCS Temperature (Hot Leg) Element I Containment i I

See 2.18 l

I I

2 ITERC3B4 i RCS Temperature (Hot Leg) Element I Containment l l

See 2.18 I

I I

2 ITERC3A4 l RCS Temperature (Hot Leg) Element I containment l l

See 2.18 l

l l

2 ITERC4A2 i RCS Temperature (Cold Leg) Element l Containment l l

See 3.01 l

l l

2 ITERC4A4 i RCS Temperature (Cold Leg) Element i Containment l l

See 3.01 1

l l 2 lTERC4B2 l RCS Temperature (Cold Leg) Element i Containment l l

See 3.01 l

l l

2 ITERC4B4 i RCS Temperature (Cold Leg) Element l Containr>.ent l l

See 3.01 l

l l

I I

I l

i I

I I

I I

I I

I I

i l

1 1

1 I

I I

l i

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I l

l l

l 1

I I

I l

l 1

l l

l 1

I i

i I

l i

l l

I 1

l l

l l

l 1

1 I

I

.I I

I I

I I

l l

l l

1 1

I I

I i

l i

l i

i l

I I

I I

I I

I I

l l

l I

l l

1 I

l i

I I

I I

I I

I I

l l

l l

l l

1 1

I I

I I

I I

I I

I I

I I

I I

I I

i 1

i

Facilit'y Davis-Bessa Unit 1 Docket:

50-346 MASTER LIST NON-HARSH ENVIRONMENT Index No: 303M-005 Rev.:

2 DISPIJLY INSTRUMENTATION REFERENCED IN LOCA/HELB PROCEDURES Prepared by:

Date:

Checked by:

AY Oji,f' Date:

, y.?

l l

l l

l l

l l

l LOCATION l

l

\\ Worksheet l l Plant l

l Inside l

Outside l

l l

Index No.

' Rev.

ID Number l l

Primary l

Primary l

l 1

Generic Name I Containment l Containment l REMARKS l

I l

l 0 lFIS1422C l CC Water Flow Indicating Switch i

l l

l 1

l 0 IFIsl422D l CC Water Flow Indicating Switch l

l Em. 328 l

l l

l Rm. 328 l

l l

l 0

lFIS1427C l CC Water Flow Indicating Switch l

l Rm. 328 l

l l

l 0 lFIS1427D l CC Water Flow Indicating Switch l

l Rm. 328 l

l l

l 0 lFIS1432C l CC Water Flow Indicating Switch l

l Rm. 328 l

l l

l 0 lFIS1432D l CC Water Flow Indicating Switch l

l 0 lFT578 l Condensate Flow Transmitter l

l Rm. 328 l

l l

l

\\

0 lFT736 l Circulating Water Flow Transmitter l Turbine Bldg.l l

l l Turbine Bldg.l l

l l

0 lFT737 l Circulating Water Flow Transmitter l

l l

0 IF1MU31 l Makeup Nozzle Flow Transmitter l Turbine Bldg.l l

l l 0 lFTSP2Al l Main Feed Nozzle Flow Transmitter l

l l

l Rm. 225 l

l l 0 lFTSP2A2 l Main Feed Nozzle Flow Transmitter l Turbine Bldg.l l

l l 0 IFTSP2B1 l Main Feed Nozzle Flow Transmitter l Turbine Bldg.l l

l l

l 0 lFTSP2B2 l Main Feed Nozzle Flow Transmitter l Turbine Bldg.l l

l l

l 0

lLIl62 l Second Stage Reheater Drain Tank Level l

l Turbine Bldg.l l

l

\\ Turbine Bldg.l l

l l

l l

Indicator l

l 0 lLIl73 l Second Stage Reheater Drain Tank Level l

l Turbine Bldg.l l

]

l l

l l

l l

l Indicator l

l 0 lLIMU49-1 l Boric Acid Addition Tank Level Indicator l l

Rm. 240 l

l l

l l

l l

l 0 l LIMU65-1 l Boric Acid Addition Tank Level Indicator l l

Rm. 240 l

l l

j 0

lLT1525A l BWST Level Transmitter l

l 0

ILT1525B l BWST Level Transmitter l

l BWST Yard l l

l l 0 lLT1525C l BWST Level Transmitter l

l BWST Yard l l

l l 0 lLT1525D l BWST Level Transmitter l

l BWST Yard l l

l 1 0

\\LT1721 l RC Drain Tank Level Transmitter l

l BWST Yard l l

l l 0 lLT202 l Deaerator Level Transmitter l

l Rm. 106 l

l l

l 0

lLT205 l Deaerator Level Transmitter l

l Turbine Bldg.l l

l

\\

0 lLT512 l Condensate Storage Tank Level Transmitter l ITurbine Bldg.l l

l l 0 lLT516 l Condensate Storage Tank Level Transmitter l l Turbine Bldg.l l

l l 0 lLT538 l Turbine Bldg.l l

l Hotwell Level Transmitter l

1 l

l l

l Turbine Bldg.l l

I I

I l

O O

Fccilityt Davis-Esass Unit 1 MASTE2tIST Index No h403t-00%

Docket:

50-346 NON-HARSH ENVIRONMENT Rev.:

2 DISPLAY INSTRUMENTATION REFERENCED IN LOCA/HELB PROCEDURES Prepared by:

Date FJ Checked by:

xibvms Dater x.i e.A i

l l

l l

l LOCATION l

l l

l l

l l

Inside l

Outside l

l J

l Worksheet l l

Plant l

l Primary l

Primary l

l l

Index No.

l Rev. lID Number l Generic Name l Containment l Containment l REMARKS l

i I

l l

l l

l l

l l

l 0 l L'19tU16-1 l Makeup Tank Level Transmitter l

l Rm. 206 l

l l

l 0 l L'IMU16-2 l Makeup Tank Level Transmitter l

l Rm. 206 l

l i

l l 0 lPDI2657 l SU Feed Pump Pressure Differential (Flow) l l Turbine Bldg.l l

l l

l l

Indicator l

l l

l I

l l

0 lPT295 l Deaerator Pressurizer Transmitter l

l Turbine Bldg.l l

l l

0 lPT320 l Deaerator Pressurizer Transmitter l

l Turbine Bldg.l l

l l 0 lPT495 l Startup Feed Pump Discharge Pressure l

l Rm. 238 l

l l

l l

l l

l Transmitter l

l l

l j

l l

0 lPT505 l Auxiliary FW Pressure Transmitter l

l Rm. 237 l

l l

l 0

lPT509 l Auxiliary FW Pressure Transmitter l

l Rs. 238 l

l l

l l

0 lPT530

1. Main Condenser Pressure / Vacuum Transmitter l l Turbine Bldg.l l

l l 0 lPT541 l Main Condenser Pressure / Vacuum Transmitter l l Turbine Bldg.l l

3 l

l l

0 lPT2000 l Containment Pressure Transmitter l

l Rm. 400 l

l j

l l 0 lPT2340 l Gland Seal Header Pressure Transmitter l

l Turbine Bldg.l l

l l 0 lST815 l AFP Turbine Speed Transmitter l

l Rm. 237 l

l l

l 0

lST816 l AFP Turbine Speed Transmitter l

l Ra. 238 l

l l

l 0 lTE2276A l Turbine Bearing Oil Temperature Element l

l Turbine Bldg.l l

j l

l 0

lTE2276B l Turbine Bearing Oil Temperature Element l

l Turbine Bldg.l l

j l

l 0 lTIRC7A l RC Average Temperature Indicator l

l Rm. 505 l

l I

l 0

lTIRC7B l RC Average Temperature Indicator l

l Rm. 505 l

l l

l 0

l l Turbine Supervisory Instrumentation l

l Turbine Bldg.l l

l l

l l

l l

l l

l l

l l

l l

l 1

l l

l l

l l

l l

l l

l l

l l

l l

i l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l 1

l l

\\

/

/

Fccilit 't Davis-3cesa Unit 1 MASTER' GIST Ind x Nos d3M-007 Docket:

50-346 Rev.:

2 DISPLAY INSTRUMENTATION Prepared by:

Dates 82 Checked by:

M.'e >w f4 g/

Dates fc/ M 4

I I

I I

I LOCATION l

l l

l l

1 1

I Inside i

Outside l

I I worksheet l l Plant; I

l Primary l

Primary i

I I

Index No.

I Rev. IID Number I Generic Name l Containment I Containment i REMARKS I

l l

l l

l l

l l

l 1

1 I

I I

I I

I I

I I

I I

I I

l l

l l

l l

l l

l l

l l

1 1

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

l i

I I

i 4

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

i l

i i

I i

i l

I l

l l

I I

I I

I J

l l

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

a i

i l

i I

I I

I I

I I

I I

I I

I I

I I

l I

I I

I I

I I

I I

I I

I

l l

l l

1 1

I I

I 1

I I

I i

i i

I I

I I

l l

I I

I 1

I I

I I

I I

I l

l l

l 1

1 I

I I

I I

I I

I I

I l

1 I

I I

I I

I l

l l

l 1

1 I

I I

I I

I I

I I

I I

I I

I I

I I

I i

i l

I I

I i

i l

i

Facility: Dsvis-Bessa Unit 1 SYSTI!M COMPONENT EVALUATION WORKSHEET Dockst:

50-346 Index No.: 303H-033 i

Rev.:

2 Prepar6d byr d.

-__a Date: /0 J

j Checktd by: _ h A d Dates N///Fl i l ll I

l I

l

! l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qualification l' Outstanding l

!l ll Parameter Specification Qualification

' Specification Qualification!

Method Items l

l l ll l

l i lSystcm:

Display ll Operating l N/A l

Exengt l

Note 1 l

Note 1 l

N/A l

None l

l Instrumentation - ll Time l

l l

l l

l l

l l Procedures ll l

l l

l l

l l

ll ll l

l l

1 I

l l

l Plant ID No. PTCF4A1 ll Temperature l 283.0 l

Exempt l

H, X l

Note 1 l

N/A l

None l

I ll

(*r>

l l

l l

l l

l

' l Component Pressure ll l

l l

l l

l l

l l Transmitter ll l

l l

l l

l l

lll Manufacturer:

ll Pressure l

52.0 l

Exempt l

G, X

l Note 1 l

N/A l

None l

Motorola ll(PSIA) l l

l l

l l

l i l ll l

1 l

l l

l l

i l Modal Number: 56PM142 ll l

l l

l l

j l

I ll Relative l

100.0 l

Exempt l

A l

Note 1 l

N/A l

None l

l Function:

Transmits ll Humidity l

l l

l l

l l

l l Pressure Signals ll

(%)

l l

l l

l

! ll Accurscy: Spect N/A ll l

l l

l l

l Demon N/A ll l Boric Acid l

l l

l l

l Il ll Chemical l

1800 ppm l

Exempt l

A l

Note 1 l

N/A l

None l

j l Service:

Core Flood ll Spray l

pH 5.0 l

l l

l l

l 1l Tank Pressure ll l

l l

l l

l l

j l ll l

l l

l l

l l l Location: Containment ll l

l l

l l

l l

i l ll Radiation l1. 0 x 108 RADS l Exempt l

A l

Note 1 l

N/A l

None l

!l ll l

l l

l l

l l

l l Flood Level Elev: 572'-2"ll l

l l

l l

l

} lAbove Flood Level N/A ll Aging l

40 Years l

Exempt l

I l

Note 1 l

N/A l

None l

1I 1l l

l l

l l

l l

l lNeeded fors ll l

l l

l l

l l

}l Hot Shutdown l

l ll l

l l

l l

l l

~ l l lSubmergencel 572' - 2" l

Exempt l

B l

Note 1 l

N/A l

None l

j l Cold Shutdown l l

ll l

l l

l l

l l

1 ll l

l l

l l

l l

t i

f\\ })

Lb J

FEcility: Divio-Cessa Unit 1 SYSTEM COMPONENT EVALUATION WORKSHEET Ind x No. : 303H-033A Dockst:

50-346 Rev.:

2

[O /c p}

Prgpared by:

__ {e_= 2 t,

_Date Chrcked by:

,4ppr4_ D. _, Mate /////f3

/

l.

These instruments are exempt from qualification because they are not considered to be safety related. They only function to provide a computer input as supplementary information. The computer is not considered to be safety-related and it may be escured during an accident. In the event of a DBA LOCA or HELB inside containssent causing the harsh environment, an SFAS signal will isolate these lines and therefore cause flow to go to zero. The operator is aware of the instruments?

i non-safety-related status and will not be misled by erroneous indication. Since the instrument does not perform a control function, accident mitigation will not be affected by its failure.

1 i

5 3

1

e k

\\

Fccilitys 'Dsvic-Beses Unit 1 SYSTDI COMPONENT EVALUATION NORKSHEET Dockst:

50-346 Index No.: _30351-034 i

Rev.:

2 Prepared by:

h!de_-_ [

Date: [O d 8)

Checksd by:

_ M M _ d Datea v////E 7

l l

ll l

l l

l I

l EQUIPMENT DESCRIPTION ll ENVIRONMENT DOCUMENTATION REF.

l Qualification l Outstanding l

]

]

ll Parameter Specification Qualification Specification Qualification l Nethod l

Items l

l ll l

)

lSystsm:

Display ll Operating l N/A l

Exeg t l

Note 1 l

Note 1 l

N/A l

None l

i l

l l

l Instrumentation - ll Time l

l l

l l

l l

4 l

Procedures ll l

l l

l 1

ll t

l 1

l I

l l Plant ID No. PTCF4A2 l l Temperature l 283.0 l

Exempt l

H, X l

Note 1 l

N/A l

None l

I l

i 1

ll

(*r>

l l

l l

l l

l l Component: Pressure ll l

l l

l l

l l

3 l

Transmitter ll l

l l

l l

l l

l ll Pressure 1

52.0 l

Exempt l

G, X l

Note 1 l

N/A l

None l

l Manufacturer: Motorola ll(PSIA) l l

l l

l l

l 1

ll l

l l

1 l

l l

IMod31 Number: 56PM142 ll l

l l

l 3

l l

l ll Relative l

100.0 l

Exempt l

A l

Note 1 l

N/A l

None l

l Function:

Transmits ll Humidity l

l l

l l

l l

} l Pressure Signals ll

(%)

l l

l l

l l

l l Accuracy: Spec:

N/A ll l

l l

l l

l l

I l Demon N/A ll l Boric Acid l

l l

l l

l

) ll l] Chemical l

1800 ppm l

Exempt l

A l

Note 1 "l

N/A l

None l

j Sarvice Core Flood ll Spray l

pH 5.0 l

l l

l l

l 1

Tank Pressure ll l

l l

l l

l l

l l ll l

l l

1 l

l l

' l Location: Containment ll l

l l

l l

l l

l ll Radiation l 1. 0 x 108 RADS l Exempt l

A l

Note 1 l

N/A l

None l

l ll l

l l

l l

l IFlood Level Elev: 572 '-2" l l l

l l

l l

l l Abova Flood Level: N/A ll Aging l

40 Years l

Exegt l

I l

Note 1 l

N/A l

None l

I ll l

l l

l l

l l

lNesdsd for ll l

l l

l l

l l

Hot Shutdown l

l ll l

l l

l l

jl l l Submergence l 572' - 2" l

Exempt l

B l

Note 1 l

N/A l

None l

l 1

' l Cold Shutdown l l

ll l

l l

l l

l l

.l ll l

l l

l l

l l

I i

4 1

)

O C')

Facility: DkV12-Dossa Unit 1 SYSTI!M COMPONENT EVAbdION WORKSHEET Ind x Nh M 303H-034A Dockst:

50-346 Rev.:

2 I

/

<P_7 Prsparsd by:

,Date Checksd by: M A d - # Date v// fps 1.

These instruments are exempt from qualification because they are not considered to be safety related. They only function to provide a computer input as supplementary information. The computer is not considered to be safety-related and it may be escured during an accident.

In the event of a DBA LOCA or HELB inside containment causing the harsh environment, an SFAS signal will isolate these lines and therefore cause flow to go to zero. The operator is aware of the instruments' non-safety-related status and will not be misled by erroneous indication. Since the instrument does not perform a control function, accident mitigation will not be affected by its failure.

1 i

4 i

i

Fecility: Davic-B0sso Unit 1 SYSTEM COMPONENT L.LLUATION WORKSHEET IndIx Ntir[ 303H-035 Dockat:

50-346 Rev.

2 Preptred by:

Dater /

MJ Checksd by:

- % y % - f Dates y/s/P3 l

ll l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRONMENT DOCUMENTATION REF.

l Qualification l Outstanding l l

ll Parameter l Specification l Qualification iSpecification Qualification l Method l

Items l

l ll l

l 1

l l

l l System:

Display ll Operating l N/A l

Exempt l

Note 1 l

Note 1 l

N/A l

None l

l Instrumentation - ll Time l

l l

l l

l l

l Procedures ll l

l l

l l

l l

l ll l

l l

l l

l l

l Plant ID No. PTCF4B1 ll Temperature l 283.0 l

Exempt l

H, X

l Note 1 l

N/A l

None l

l ll

<*F) l l

1 l

l l

l l Component: Pressure ll l

l l

l l

l Transmitter ll l

l l

l l

l l

ll Pressure l

52.0 l

Exempt l

G, X l

Note 1 l

N/A l

None l

1 l Manufacturer: Motorola ll(PSIA) l l

l l

l l

l l

ll l

l l

l l

l l Modal Numbers 56PM142 ll l

l l

l l

l l

t l

ll Relative l

100.0 l

Exempt l

A l

Note 1 l

N/A l

None l

i l Function:

Transmits ll Humidity l

l l

l l

l l

l Pressure Signals ll

(%)

l l

l l

l l

l Accuracy: Spect N/A ll l

l l

l l

l l

l Demon:

N/A ll l Boric Acid l

l l

l l

l l

l ll Chemical l

1800 ppm l

Exengt l

A l

Note 1 l

N/A l

None l

l lSarvice:

Core Flood ll Spray l

pH 5.0 l

l l

l l

l l

l Tank Pressure ll l

l l

l l

l l

i l

ll l

l l

l l

l lIncation : Containment ll l

l l

l l

l 8

l ll Radiation l1.0 x 10 RADS l Exempt l

A l

Note 1 l

N/A l

None l

l l

ll l

l l

1 I

l Flood Level Elev: 572'-2"ll l

l l

l l

l i

i lAbova Flood Level: N/A ll Aging l

40 Years l

Exempt l

I l

Note 1 l

N/A l

None l

l ll l

l l

l l

l l

lNerded for ll l

l l

l l

l l

~

l l

Hot Shutdown l

l ll l

l l

l l

l l

l l l Subme rgencel 572' - 2" l

Exempt l

B l

Note 1 l

N/A l

None l

l Cold Shutdown l l

ll l

l l

l l

l l

l ll l

l l

l l

l l

\\

')

)

(m\\

s Facility: D'5vis-Desce Unit 1 SYSTEM COMPONENT EV'JAJION WORKSHEET Index No.v 303H-035A Dockst:

50-346 Rev.:

2 OD Prspared by:

Date Checked by

_"t @ d _ [ Date /////JJ 1

1.

Thase instruments are exempt from qualification because they are not considered to be safety related. They only function to provide a computer input as supplementary information. The computer is not considered to be safety-related and it may be secured during an accident. In the event of a DBA LOCA or HELB inside containment causing the harsh environment, an SFAS signal will isolate these lines and therefore cause flow to go to zero. The operator is aware of the instruments' non-safety-related status and will not be misled by erroneous indication. Since the instrument does not perform a control function, accident mitigation will not be affected by its failure.

l 1

1 I

i j

4 1

1 I

n

(

)

(n) s i

Fccility: D M E-Be =<a Unit 1 SYSTD4 COMPONENT ATION WORKSHEET Ind.x Nk/ 303H-036 DockIts 50-346 Rev.:

2

/0 p

Preparcd by:

Dater Checksd by:

hm. // Dates

/////f3 l

ll l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qualification l. Outstanding l l

ll Parameter l Specification Qualification l Specification Qualification Method l

Items l

l ll l

l 1

i l

lSyntcm Display ll Operating l N/A l

Exempt l

Note 1 l

Note 1 l

N/A l

None l

l Instrumentation - ll Time l

l l

l l

l l

l Procedures ll l

l l

l l

l l

ll l

l l

l l

1 l

l Plant ID No. PTCF4B2 ll Temperature l 283.0 l

Exempt l

H, X

l Note 1 l

N/A l

None l

l ll

(*r) l l

l l

l l

l l Component: Pressure ll l

l l

I l

l l

Transmitter ll l

l l

l l

l l

l ll Pressure l

52.0 l

Exempt l

G, X l

Note 1 l

N/A l

None l

lManufteturer: Motorola l l (PSIA )

l l

l l

l l

l l

ll l

l l

l l

l Modal Number: 56PM142 ll l

,. A l

l l

ll Relative l

100.0 i

Exempt l

A l

hote 1 l

N/A l

None l

l Function:

Transmits ll Humidity l

f.

l l

l l

l l

Pressure Signals ll

(%)

l l

l l

l l

lAccurtcy: Spec:

N/A ll l

l l

l l

l l

l Demon N/A ll l Boric Acid l

l l

l l

l l

ll Chemical l

1800 ppm l

Exempt l

A l

Note 1 l

N/A l

None l

lS2rvice:

Core Flood ll Spray l

pH 5.0 l

l l

l l

l l

Tank Pressure ll l

l l

l l

l l

l ll l

l l

l l

lIncItion : Containment ll l

l I

l l

l l

8 l

ll Radiation l1.0 x 10 RADS l Exempt l

A l

Note 1 l

N/A l

None l

l ll l

l l

l l

l l

l Flood Level Elev: 572'-2"ll l

l l

l l

l lAbova Flood Level: N/A ll Aging l

40 Years l

Exempt l

I l

Note 1 l

N/A l

None l

l ll l

l l

l l

l l

lNe ded for:

ll l

l l

l l

l l

l Hot Shutdown l

l ll l

l l

l l

l l

l l l Subme rgencel 572' - 2" l

Exempt l

B l

Note 1 l

N/A l

None l

l Cold Shutdown l l

ll l

l l

l l

l l

l ll l

l l

l l

l l

Facility: Dsvis-Be223 Unit 1 SYSTEM COMPONENT EV1. TION WORKSHEET Ind;x Non 303H-036A Dockst:

50-346 Rev.:

2 Prtpered by:

l 4 Date /# /

DJ Checksd by: J ;/c J - [ Date /////S 1.

These instruments are exempt f rom qualification because they are not considered' to be safety related. They only function to provide a computer input as supplementary information. The computer is not considered to be safety-related and it may be secured during an accident. In the event of a DBA LOCA or HELB inside containment causing the harsh environment, an SFAS signal will isolate these lines and therefore cause flow to go to zero. The operator is aware of the instruments' non-safety-related status and will not be misled by erroneous indication. Since the instrument does not perform a control function, accident mitigation will not be affected by its failure.

9 6

4 1

i, i

i t

I

.