ML20083A222

From kanterella
Jump to navigation Jump to search
Rev 2 to Procedure 1040-001-026, Containment Gas Analyzer Sys & Radiation Monitoring Sys
ML20083A222
Person / Time
Site: Davis Besse 
Issue date: 11/02/1983
From:
TOLEDO EDISON CO.
To:
Shared Package
ML17150A231 List:
References
1040-001-026, 1040-1-26, IEB-79-01B, IEB-79-1B, NUDOCS 8312200217
Download: ML20083A222 (40)


Text

.

l CALCULATION / PROBLEM COVER SHEET Calculation / Problem No: 1040-001-026

Title:

Containment Gas Analvzer System & Radiation Monitor'ing System 2.23 Cilent: Toledo Edison Company Project: Davis-Besse Unit 1 Job No: 1040-001-671 I&E Bulletin 79-01B Equipment Qualification Design input /Reforences:

Design Inputs are outlined in the Cover Report.

Ascumptions:

Assumptions are outlined in the Cover Report.

M thod:

Methods are outlined in the Cover Report.

R; marks:

EDS Nuclear Report No. 02-1040-1076.

REV. NO.

REVISION APPROVED DATE O

h.-

[0-2-Q[

se 2 sw wwsiocj_ rykhelsa) t/s/es i

SY1/ Si..'i.

3,: ![

$6 J)&

N2 88

$D/LA~PL N/IN:ML 2

/

/ /

8312200217 831129 PDR ADOCK 05000346 P

PDR f

f sesocom m

/

/

Prcili Davis-Basca Unit 1 MAh LIST Ind3x Nor"A23M-001 4

Dockst:

50-346 HARSH ENVIRONMENT Rev.:

2 CONTAINMENT GAS ANALYZER Af!D RADIATION MONI'IORING SYSTEM Prepared by:

Date

/

Checked by:

M*N_d Date /// M /J 3

l l

l l

l l

LOCATION l

l l

l l

l l

l Inside l

Outside l

l l Worksheet l l Plant l

l Primary l

Primary l

l l

Index No.

I Rev. lID Number l Generic Name l Containment l Containment l REMARKS l

I I

I I

i 1

l l

l 223H-005 l

2 lMV5010A l Valve Motor Operator i

Rs. 316 l

l l

l 223H-006 l 2 lMv5010B l Valve Motor Operator l

l Rm. 314 l

l 3

l 223H-007 l 2 lMV5010C l Valve Motor Operator l

Rs. 407 l

l l

I i

l 223H-008 l 2 lMV5010D I Valve Motor Operator l

l Rs. 314 l

l I 223H-009 l

2 lMV5010E l Valve Motor Operator l

l Rs. 314 l

l l

l 223H-010 l

2 lMV50llA l Valve Motor Operator l

l Rm. 303 I

l J

l 223H-011 l

2 lMV50118 l Valve Motor Operator 1

Rm. 410 l

l l

t 223H-012 l

2 lMV5011D I Valve Motor Operator l

Rs. 315 l

t l

4 l 223H-013 l

2 lMV5011E l Valve Mottr Operator l

l^

Rs. 314 l

l l

l 223H-014 l

2-lMV50300 i Valve Motor Operator l

l Rs. 303 l

l l 223H-015 l 2 lPSH5029 l Pressure Switch l

l Rs. 314 l

l l 223H-016 l 2 l PSH5030 l Pressure Switch l

l Rs. 303 l

l I 223H-017 l

2 l Deleted l

l l

l l

l 223H-018 l 2 l Deleted l

l 1

l l

l 223H-019 l

2 lRE2387 l Radiation Detector l

Rm. 407 l

l l

i l 223H-020 l

2 IRE 2389 i Radiation Detector l

Rm. 410 l

l l

l 223H-021 1

2 l Deleted l

l l

l l

j l 223H-022 l

2 l Deleted l

l l

l l

j l 223H-023 l

2 IAE5027 l Gas Analyzer Panel l

l Rm. 304 l

l l 223H-024 l

2 lAE5028 l Gas Analyzer Panel l

l Rm. 304 l

l 3

l l

2 l BYE 2 l Motor Control Center l

l Rm. 304 l

See 2.21 l

4 l

l l 2 lBYF2 l Motor Control Center l

l Rm. 427 l

See 2.21 l

l l

2 IBE16A l Motor Control Center l

l Rm. 515 l

See 2.21 l

l 1

~2 lBF168 i Motor Control Center l

l Rm. 500 l

See 2.21 l

l l 2 lCDYE2 l Disconnect Switch Cabinet I

l Rs. 304 l

See 2.21 l

l l

l 2

(CDYF2 l Disconnect Switch Cabinet l

l Rm. 427 l

See 2.21 l

i l

?

2 lEV1544 l Terminal Block Box l

l Rm. 303 l

See 2.21 l

1 l

l 2 lEV50108 l " minal Block Box l

l Rm. 314 l

See 2.21 l

l l

2 lEV5010D l Terminal Block Box l

l Rm. 314 l

See 2.21 l

]

l l

2 lEV607 l Terminal Block Box l

l Rm. 314 l

See 2.21 i

l l

l 2

lJT2917 l Splice Kit l

Rm. 215 l

l See 2.21 l

l I

l l

l l

l l

l 4

l 9

i m

Fccility: Davis-Besso Unit 1 MASTER LIST Docket:

50-346 Index No: 223M 002 HARSH ENVIRONMENT Rev.:

2 CONTAINMENT GAS ANALYZER AND RADIATIN MONITORING SYSTEM Prepared by:

Date

/h2 Checked by: j df)* M Date_tf/>//3 i

)

l l

l l

l LOCATION l

l l

l l

l l

Inside l

Outside l

l l Worksheet l l Plant l

3 l

Index No.

l Rev. lID Number l

Primary l

Primary l

l Generic Name i

1 I

l Containment l Containment i REMARKS l

l l 2 lNv5C10B l Push Button Switch l

l l

l l

l Rm. 314 l

See 2.21 l

l l 2 lPICSS l Penetration Assembly l Containment l Annulus l

See 2.21 l

l l

2 lP2CSC l Penetration Assembly IContainment l Annulus 1

See 2.21 l

i 1

l l 2 lNV5010D l Push Button Switch I

I l 2 lNV5010E l Push Button Switch l

l Rm. 314 l

See 2.21 l

l l

Rm. 314 l

See 2.21 l

l l 2 lNV50llA l Push Button Switch l

l Rm. 303 l

See 2.21 l

l l 2 lNV50llE l Push Button Switch l

l Rm. 314 l

See 2.21 l

j l

l 2

lNV50290 l Push Button Switch l

l Rm. 314 l

See 2.21 l

l l

2 lNV50300 l Push Button Switch l

l Rm. 303 l

'See 2.21 l

l l 2 lRC3701 l Relay Cabinet l

l Rm. 314 l

See 2.21 l

l l

2 lRC3702 l Relay Cabinet

}

l l 2 lRC3706 l Relay Cabinet l

l Rm. 314 l

See 2.21 l

l l

l Rm. 304 l

See 2.21 l

l l 2 lRC3703 l Relay Cabinet l

l Rm. 314 l

See 2.21 l

1 l

l 2

l RE4597AA l Radiation Elenent l

l Rm. 303 l

See 3.02 l

l l

2 lRE4597BA l Radiation Element 1

l Rm. 314 l

See 3.02 l

I I 2 lRr4597AA l Radiation Transmitter l

l 2 lRT4597AB l Radiation Transmitter l

l Rm. 304 l

See 3.02 l

l l 2 lRE4597AB l Radiation Element l

l Rm. 304 l

See 3.02 l

l l

2 lRE4597BB l Radiation Element l

l Rm. 303 l

See 3.02 l

l l

Rm. 314 l

See 3.02 l

l l

2 lRE4596A l Radiation Element l Containment l l

See 3.02 l

l l 2 lRE4596B

l. Radiation Element l Containment l l

See 3.02 l

l l

l l

1 1

l l

l 1

l l

1 1

I I

I I

l l

l l

1 I

)

i I

I I

i l

l l

l I

I I

I l

l l

1 1

l l

l l

I I

I I

i l

l 1

I l

1 1

I I

I I

I I

I I

I I

I I

I I

I I

I l

q\\ _.

U b("

A Facility: Davic-Becco Unit 1 Docket:

50-346 MASTER LIST NON-HARSH ENVIRONMENT Index Not _223M-003 CONTAINMENT GAS ANALYZER AND RADIATION MONITORING SYSTEM Rev.:

2 Prepared by:

N Date_

Checked by: M cj M Date j(/'/f3 l

l l

l l

l l

l

(

LOCATION l Worksheet l l Plant l

l Inside l

Outside l

l l

l l___ Index No.

I Rev.

IID Ntsnber l l

Primary l

Primary l

l l

1 I

l Containment l Containment l l

Generic Name l

l 1

lC5716 REMARKS I

l Engineering Saf ety Feature Panel I

I l

l l

l 0 IC5717 l

l Rm. 505 l

l l Engineering Safety Feature Panel l

l 0 lC5755B l Radiation Monitoring Cabinet l

l Rm. 505 l

1 l

l 0 lC5762B l Radiation Monitoring Cabinet l

l Rm. 505 l

l l

1 0 lEV50 llc l Terminal Block Box l

l Rm. 505 I

l l 0 IMV50 llc I Valve Motor Operator l

l Rm. 402 l

l l

l l

0 lNV50 llc l Push Button Skitch l

l Rm. 402 l

l l

0 lRC3606 l Relay Cabinet l

l Rm. 402 l

I l

l l

1 lRE2024 l Radiation Monitor l

l Rm. 319 l

l l

l 1 lRE2025 l Radiation Monitor l

l Turb. Bldg. l l

l l

1 lRE4598AA l Radiation Element l

l Turb. Bldg. l l

l l 1 lRE4598BA l Radiation Element l

l Turb. Bldg. l l

l l

1 lRE4598AB ] Radiation Element l

l Turo. Bldg. l

'l I

i 1

1RE4598BB } Radiation Element l

l Turb. Bldg. l l-l l

1 lRT459BAA l Radiation Transmitter l

l Turb. Bldg. l l

l l 1 l RT4598BA l Radiation Transmitter l

l Rat. 603 l

l l

l 1

lRT459BAB l Radiation Transmitter l

l Rm. 603 l

l l

l 1 l Rr459BBB ] Radiation Transmitter l

l Rm. 603 l

l l

l 1 lRT4597BA l Radiation Transmitter l

l Rm. 603 l

l 2

1 l

1 l Rr4597BB l Radiation Transmitter l

l Rm. 310 l

l l

l 1 lYlA l

l F/rt. 310 l

l l 120V Electrical Distribution Panel l

l 1

lY2A l

l Rm. 429 l

l l 120V Electrical Distribution Panel l

l l

l l

Rn. 428 l

l l

l 1

1 I

l 1

l l

1 1

I l

I I

l l

l I

I I

1 l

l l

1 I

I l

I l

l I

I I

I 1

I I

I 1

I I

I l

l l

l 1

I I

i i

i I

I I

i i

i i

i l

I i

l I

I I

I l

i l

I i

I i

1

_I

O O

s b

Ftcility: Davic-Becce Unit 1 Docket 50-34G MASTER LIST Index No 223M-004 CONTAINMENT GAS ANALYZER AND RADIATIGt MONITORING SYSTEM Rev.:

2 Prepared by:

N k /![i Date Checked by:

_M W Date f//J//L I

I i

l I

I I

I i

LOCATION I

'l I Worksheet l I Plant l

I Inside i

Outside l

l l

Index Ho.

I Re v.

IID Number i l

Primary

'l Primary i

I l

l l

l l

I Contalnment I Containment l REMARKS I

Generic Name I

I I

I l

l l

l I

I I

I I

l I

i I

I I

I I

I I

I l

i I

I I

I I

I I

I I

I I

l l

i i

l i

i I

I I

I I

I l

l l

l l

l I

I i

l i

I I

l l

l 1

j i

i i

l I

I I

1 i

i i

I I

I I

I I

i i

l i

l i

I I

i I

I I

I i

I I

I I

I I

l I

I I

I 1

I I

I i

I I

i I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

l I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I

)

l I

I I

I I

I I

I I

I I

I I

I I

1 I

I I

I I

I I

j i

l i

I I

I I

I i

i l

i l

I I

I I

I I

I I

i I

I I

j i

i i

l I

I I

I 1

I I

I i

i I

1 I

l i

I I

i 1

l I

I I

I I

I i

l.

l i

I l

i i

'N 3

Facility: D 5ic-Bessa Unit 1 SYSTEM CmPON NT EVALUATION WORKSHEET Ind:x N=.: 223H-005 Dockst:

50-346 Re v. :

2 M /!f3 Prepared by :

Date

Checksd by h n _ r L _//'

Dater g////3 l

ll l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRW MENT l

DOCUMENTATION REF.

l Qualification l Outstanding l l

l l Pa rameter Specification l Qualification I Qpecif ication Qualificc*. ion Method Items I

I ll l

l 1

l l Systems containment Gas liqperating l 1 Year l

1.1 Years l

F l

M-26 l Simultaneous l None l

l l Analyzer and Radiation l l Time l

l l

lV-24C, V-24E l Test l

l i I l Monitoring ll l

l l

l Note 1 l

l l

l Plant ID No.

MV5010A ll l

l l

l l

l l

4 l

l lTemperatu re l 283.0 l

300.0 l

H, X

l M-26 l Simultaneous l None l

l l Component : Valve Motor ll

('F) l l

l lV-24C, V-24E l Test l

l l

1 l qperator ll l

l l

l l

l I l ll l

l l

l l

l l

lManuf teture r Limitorque l l Pressu re l

52.0 l

84.7 l

G, X

l M-26 l Simultaneous l None l

ll(PSIA) l l

l lV-24C, V-24E l Test l

l i

l Modal Number SMB-000-2 ll l

l l

l 4

l l

lO/N: 386244A ll l

l l

~

l l

l i l l l Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

l Function: Operates Con-ll Humidity l

l l

lV-24C, V-24E l Test l

l l tainment Atmosphere Mon-ll

(%)

l I

l l itoring System Valve ll l

l l

l

] l Penstration 71B ll l Boric Acid l

Boric Acid l

l M-26 l

l l

j l Accuracy : Spect N/A l l Chemical l

1800 ppm l

1800 ppm l

A lV-24C, V-24E l Simultaneous l None l

l Demon N/A l l @p ray l

pH 5.0 l

pH 5.0 l

l CAL-40 l

Test, l

l lSarvice: Containment Air ll l

l l

l Note 2 l

Analysis l

l t

l Sample Isolation ll l

l l

l l

l l

,l Valve ll l

I l

l l

l l

7 8

l Location: Containment ll Radiation l1.7 x 10 RADS l2.0 x 10 RADS l CAL-44 l

M-26 l Sequential Test l None l

ll ll l

V-240, V-24E l l

l

] l Flood Level Elev: 572'-2"ll l

l l

l I l Abova Flood Level: Yes ll Aging l

40 Years l

40 Years l

I l

CAL-93 l Sequential Test l None l

jl ll l

l

.l l

l Analysis l

l

' lNeedad for ll l

l l

l l

l l Hot Shutdown lxl ll l

l l

l l

l 1ll l l Subme rge ncel 572'-2" l 588'-10-1/2" l

B l

M-20 l

N/A l

None l

l Cold Shutdown lX l ll l

l l

l l

l l

Il ll l

l l

l l

l l

l

]

l I

/' N s

O h

\\.

\\

atcility: Dav v-Dcs"Je Unit 1 SYSTEM CCtPONENT EVALUAz. 3 WoltKSilEET Ind2x Fo.: h;al-005A Rev.

~ ' f, xkst:

50-346 ll,/( j[ [8 NOTES reparsd by:

h Date 1scked by ' g Date g g]_

y 1

h

%s test subjected the valve motor operator to a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120'F in 3.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

%e valve motor operator was tien subjected to a second transient of 300*F and 44.7 psia, which was s:aintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for 24 days. %e temperature and i

pressure inside containment peak at 283*F and 52.0 psia in 17 and 50 seconds, respectively. At I hour the conditions are i

214.7'F and 32.2 psia; at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> the conditions are 204*F and 29.46 pe;ia; at 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> the conditions are 193.2*F and 27.08 paia; and at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> the conditions are 143*F and 18.03 psia.

%e coriditions return to ambient in 7 days.

Based on this information, it can be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result from a postulated IDCA.

Since the valve motor operator remained operable throughout the test and functional af ter the test, it can be concluded that the valve motor operator will remain f unctional during and af ter exposure to the accident environment which would result f rom the postulated LOCA.

( Ref erence G, II, and X).

. CAL-40 qualifies components tested in a high pil boric acid spray to a pil value of 5.

1

]

I 1

3 4

e S

1 4

i k

f

,,m

/q

(}/

('

[

\\

l t

f s

/

Pfeility: L.<ls-B;;ro Unit 1 SYSTEM COMPONENT'LtALUATION WORKSHEET

'-s Index No.: 223H-006 Dockst:

50-346 Rev.:

2 Prcpared by:

b, Date:

N/

Ch:cked by:

,_ ;8U- # [

Date:

J>/)/ll[

j 4

s l

ll l

1 1

1 l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REP.

l Qualification 1 Outstanding l l

ll Parameter i specification l Qualification ISpecificationloualificationl Method l

Items l

I 11 1

I l

l l

1 l

lSystsm: Containment Gas l! Operating l

1 Year i

1.1 Years l

P l

M-26 l Simultaneous l None 1

1 Analyzer and Radiation ll Time i

l l

l V-24E I

Test l

l l

Monitoring ll l

l l

l Note 1 l

l l

l Plant ID No. MV5010B ll l

l l

l l

l l

1 llTemperaturel 221.0 1

300.0 i

C-314 l

M-26 l Simultaneous l

None l

l Component: Valve Motor ll

(*F) l l

l l

V-24E i

Test i

l l

Operator ll l

l l

l l

l l

l Manufacturer: Limitorque ll l

l l

l l

l l

l llPressure j

19.76 I

84.7 i

C-314 l

M-26 i Simultaneous l

None l

l Modal Number: SMB-000-5 ll(PSIA) l l

l l

V-24E I

Test l

l lO/N: 386244B ll l

l l

l l

l 1

1 11 l

l l

l l

1 I

IFunction: Operates Con-ll Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l

None l

l teinzent Atmosphere Mon-llHumidity l

l l

l V-24E l

Test l

l l itoring System Valve ll (t)

I f

l l

t 1

l l Pan 2tration 68B ll l

l l

l l

l l

l Accuracy: Spec:

N/A ll l

l l

l l

l 1

l Deron: N/A ll Chemical l

N/A l

N/A l

N/A I

N/A l

N/A l

None l

lSarvice: Containment Air llSpray l

l i

l l

l l

l Sample Isolation ll l

l l

l l

l 1

l Valve ll l

l l

l l

l l

l Location : Auxiliary Bldg.ll l

l l

l l

l l

6 8

l Rm. 314 llRadiation 11.0 x 10 RADS 12.0 x 10 R ADS l T

l M-26 l Sequential Testl None l

l ll I

l l

l V-24E l

l l

lPlood Level Elev:

N/A ll l

l l

l l

l l

l Abova Flood Level: N/A ll Aging l

40 Years 1

40 Years l

I l

CAL-93 l Sequential Testl None l

l 11 l

l l

l l

Analysis I

lNcadad for:

ll l

l l

l l

l l

l Hot Shutdown IX l ll l

l l

l l

l l

l ll Submergence l N/A l

N/A l

N/A l

N/A l

N/A l

None l

l Cold Shutdown IX l ll l

l l

l l

l l

1 ll l

l 1

1 l

l 1

f l

3 i

V U

s Fr.cility: Davis-Desse Unit 1 SYSTD1 COMPONENT EVALUATION WORKSHEET Indsx No.: 223H-006A

, 3nckst 50-346 Rev.:

f I

NOTFE Prepared by b

N l pl Date j

Jacksd by: Mdmg g Date 18 / 2 El 5 '

1.

%s test subjected the valve motor operator to a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120'F in 3 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.' The valve motor operator was then m2bjected to a 'second transient of 300*F and 44.7 psia, which was maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia,' which was maintained for 24 days.

De temperature in Room 4

314 peaks at 221*F in 1 55 seconds. The pressure in Room 314 peaks at 19.76 psia in.086 seconds. The conditions in Room 314 return to ambient af ter 8 minutes.

Based on this information, it can be concluded that the laboratory test subjected the valve motor operator to an overall 4

more severe environment than that which would result f rom a postulated HEIE.

Since the valve motor operator remained f

operable throughout the test and functional af ter the test, it can be concluded that the valve motor operator will remain functional during and af ter exposure to the accident environment which would result f rom the postulated HELB.

(Ref erence C-314) 4 t

O Y

Fccility: b eis-Besse Unit 1

\\

Dockst 50-346 SYSTEM COMPONENT EVALUATION WORKSHEET Index ho.: 223H-007 Rev. :

2 Prepared by:

N Date M/

3 3

. Checksd by: _hu Od Date:

N/.2/O i

j l

ll l

l l

l ;

j l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qcalification l Outstanding l j l ll Parameter l Specification l Qualification lEDecificationl Qualification l l

ll 1

I i

l l

l l 1 Method l

Items l

l Systems Containment Gas ll Operating l 1 Year l

1.1 Years l

F l

M-26 l Simultaneous l None l

l Analyzer and Radiation l l Time l

l l

l V-24C l

Test l

l i

)j l Monitoring ll l

l l

l Note 1 l

l l

lPlcnt ID No.

Mv5010C ll l

l l

l l

l l

l l l Temperature l 283.0 l

300.0 l

H, X

l M-26 l Simultaneous l None l

j lCouponent : Valve Motor ll

(*F) l l

l l

V-24C' l

Test l

l l

Cherator ll l

l l

l l

l l

l ll l

l

__1 l

l l

l l lMRnufacturer Limitorque ll Pressure l

52.0 l

84.7 l

G, X l

M-26 l Simultaneous l None l

l l l (PSIA )

l l

l l

V-24C l

Test l

l l Modal Number SMB-000-2 ll l

l l

l l

l l

l O/N 386244A ll l

l l

l l

i l

ll Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

l l

l Function: Operates Con-ll Humidity l

l l

l V-24C l

Test l

l l tainment Atmosphere Mon-ll

(% )

l l

l l

l l

j l

l itoring System Valve ll l

l l

l l

l

/

l Penstration 73B ll l Boric Acid l Boric Acid l

l M-26 l

l l

1 1 l Accuracy: Spec t N/A ll Chemical l

1800 ppm l

1800 ppm l

A l

V-24C l Simultaneous l None l

'l Demon N/A l l Sp ray l

pH 5.0 l

pH 5.0 l

l CE-40 l

Test, l

l

' lSarvice : Containment Air ll l

l l

l Note 2 l

Analysis l

l

'l Sample Isolation ll l

l l

l l

l l

) ll Location :

Valve ll l

l l

l l

l l

4 Containment ll Radiation l1.7 x 107 RADS l2.0 x 108 RADS l CAL-44 l

M-26 l Sequential Test l None l

il ll

]l Flood Level Elev: 572 '-2 "l l V-24C l

l l

}ll Above Flood Level l

l l

Yes ll Aging l

40 Years l

40 Years l

I l

CAL-93 l Sequential Test l None l

ll l

l l

l l

Analysis l

l

!lNasdsd fors ll l

l l

l l

l

l Hot Shutdown lXl ll l

l l

l l

l

l l l Subme rgencel 572'-2" l

610'-3" l

B l

M-22 l

N/A l

None l

l Cold Shutdown lX l ll l

l l

l l

l l

0 ll l

l l

l l

l l

I l

i i

1

I

},

  • acility : Davu -Bessa Unit 1 SYSTEM COMPONENT EVALUAuw;f WORKSHEET Indtx No.: h d-007A i ocksts 50-346 Rev.:

3 1 *reparsd by Date l( l gf hacksd by 2M_

hDate- }l

_yy j

i

%s test subjected the' valve motor operator to a transient' of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120*F in 3.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

%e valve motor operator was then subjected to a second transient.of 300*F and 44.7 psia, which was i

maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for 24 days. %e temperature and pressure inside containment peak at 283*F..and 52.0 psia in 17 and 50 seconds, respectively. At I hour the conditions are l

214.7'r and 32.2 psia s at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> the conditions are 204*F and 29.46 psia s at 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> the conditions are 193.2*F and 27.08 i

paia; and at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> the conditions are 143*F and 18.03 psia. %e conditions return to ambient in 7 days.

a j

Basad on this information, it can be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result f rom a postulated IDCA.

Since the valve motor operator remained operable throughout the test and functional af ter the test, it can be concluded that the valve motor operator will remain j

f unctional durisvj and af ter exposure to-the accident environment which would result f rom the postulated IPCA.

(Reference G, j

H, and X).

j CAL-40 qualifles components tested in a high pH boric acid spray to a pH value of 5.

I i

l l

4 1

2 1

1 9

i

}

i i

4 i

1

fFacility: D M D-Bezze Unit 1 SYSTEM CMPONENT UUATIN NORKSHEET IndIx L j 223H-008,

Re v. :

2 j Dockst 50-346 W

[

Prepcred by:

Date Checksd by:

,,a(/s# Od Date: <////d >

I Il l

l l

l 1 l EQUIPMENT DESCRIPTION ll ENVIRONMENT DOCUMENTATION REF.

l Qualification l Outstanding l j l l l Pa rameter Specification Qualification

%ecification Qualification Method Items l

l ll ll i

l l Systems Containment Gas ll Operating l 1 Year l

. l.1 Years l

F l

M-26 l Simultaneous l None l

i l An:lyzer and Radiation l l Time l

l l

l V-24E l

Test l

l

}l Monitoring ll l

Note 1 l

l Plant ID No. MV5010D ll l

l I

l 1

l l l Temperature l 221.0 l

300.0 l

C-314 l

M-26 l Sircultaneous l None l

I l Component: Valve Motor ll

(*F) l l

l l

V-24E l

Test l

l ll Operator ll l

l l

l l

! lManuf acturer Limitorque ll l

l l

l I

l l

l l l Pressure l

19.76 l

84.7 l

C-314 l

M-26 l Simultaneous l None l

1 lModel Number SMB-000-5 ll(PSIA) l l

l l

V-24E l

Test l

l 3

386244B ll l

l l

l l

l llO/N:

l ll l

l l

l I

I i

j l Function: Operates Con-ll Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

l l tainment Atmosphe re Mon-l l Humidity l

l l

l V-24E l

Test l

l l l itoring System Valve ll

(%)

l l

l l

l l

l

} l Panstration 74B ll l

l l

l l

l l

ll Accuracy: Spect N/A ll l

l l

l l

l l

l l Demon: N/A ll Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

None l

l Service: Containment Air ll@ ray l

l l

l l

l l

l Sample Isolation ll l

l l

l l

l l

! l Valve ll l

l l

l l

l l

l Location: Auxiliary Bldg.ll l

l l

l l

l l

!l Rm.,314 ll Radiation l1.0 x 10 RADS l2.0 x 10 RADS l T

l M-26 l Sequential Test l None l

6 8

l V-24E l

l l

)l ll l l Flood Level Elev N/A.ll l

l l

l

} l Above Flood Level N/A ll Aging l

40 Years l

,40 Years l

I l

CAL-93 l Sequential Test l None l

}l ll l

l l

l l

Analysis l

l Nasdad fors ll l

l I

l Hot Shutdown lX l ll l

l l

l l

l l Subme rgencel N/A l

N/A l

N/A l

N/A l

N/A l

None l

l Cold Shutdown lXl ll l

l l

l l

l I

l ll l

l l

l l

l l

t i

)

k acility: Davis-Bezza Unit 1 SYSTEM COMPONENT EVALUATION WORKSHEET Index Ho.: 223H-00?A

! )ckst:

50-346 Rev.:

NOTEO II!t fl repsrsd by: _k te

'secked by: g7)ff

,Date p l Z l g3_

I 22 test subjected the valve motor operator to a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to-120'F in 3 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The valve motor operator was then subjected to a second transient of 300*F and 44.7 psia, which was maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for 24 days. We temperature in Room 314 peaks at 221*F in 1.55 seconds. The pressure in Room 314 peaks at 19.76 psia in.086 seconds. The conditions in Room 314 return to ambient af ter 8 minutes.

j Basad on this information, it can be concluded that the laboratory test subjected the valve motor operator to an overall l

more severe environment than that which would result f rom a postulated llEIB. Since the valve motor operator remained operable throughout the test and functional af ter the test, it can be cor.cluded that the valve motor operator will remain j

functional durJrrJ and af ter exposure to the accident environment which would result f rom the postulated HEIB.

( Ref e rence l

C-314) i i

l i

i i

I i

't i

4 I

\\

Facility:- Davic-Be200 Unit 1 Dockst 50-346 SYSTEM CGtPOIENT EVALUATION NORKSHEET Index No.: 223H-009 Re v. :

2 Propered by:

k Dater P1 Checksd by:

MrJLAP Dater j/ /.Vf]

I II l

l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

1 l

l l l Pa rameter I Specification l

DOCUMENTATION REF.

Qualification i Ebecification Qualification ll Qualification l Outstanding l l

ll 1

i i

i l

l l

Method l

Items

{

lSyttsm: Containment. Gas l l Operating l 1 Year l

1.1 Years l

F l

M-28 l Simultaneous l None l

l Analyzer and Radiation ll Time l

l l

l V-24G l

Test l

l l

Monitoring ll l

\\

l l

Note 1 l

l Plant ID No. MV5010E ll l

l

-l l

l l

l l l Temperature l 221.0 l

250.0 l

C-314 l

M-28 l Simultaneous l None l

l l Componsnt : Valve Motor ll

(*F) l l

l l

V-24G l

Test l

l l

Operator ll l

l l

\\

l l

l

\\Msnuf teturer: Limitorque ll l

l l

l l

l l

l ll Pressure l

19.76 l

39.7 l

C-314 l

M-28 l Simultaneous l None l

lModel Number: SMB-000-5 ll(PSIA) l l

\\

l V-24G l

Test l

l

\\O/N: 382120A ll l

l l

l l

l l

lS/N: 207541 ll

{

l l

l l

1 l

l Function: Operates Con-ll Relative l

100.0 l

100.0 l

A l

M-28 l Simultaneous l None l

l tainment Atinosphere Mon-l l Humidity l

l l

\\

V-24G l

Test l

l l itoring System Valve ll

(% )

l l

l l

l l

l l Panstration 423 ll l

l l

l l

l l

l Accuracy : Spect N/A ll l

l l

l l

l l

l Demon: N/A ll Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

None l

lSarvices Containment Air l l Spray l

l l

l l

l l

l Sample Isolation ll l

l l

l l

l l

l Valve ll l

l l

l l

l l Location: Auxiliary Bldg.ll l

l l

l Rm. 314 ll Radiation l1.0 x 106 RADS l2.0 x 107 l

l l

RADS l T

l M-28 l Sequential Testl None l

)

ll l

l v-24G l

l l

Flood Lovel Elev N/A ll l

l l

l l

' Above Flood Level N/A ll Aging l

40 Years l

40 Years

.l I

l CAL-93 ISequential Test l None l

ll l

l l

l l

Analysis l

l Nacdsd for ll l

l l

I l

l l

Hot Shutdown lX l ll l

l l

l l

l l

l l Subme rgence l N/A l

N/A l

N/A l

N/A l

N/A l

None l

Cold Shutdown lX l ll l

l l

l l

l l

ll l

l 1

l l

l 1

' 3.cility: Datw -ucasa Unit 1 SYSTDi COMPONElff EVALUa.aN WORKSHEET Indtx No.: LisJ-009A

. bckst 50-u6 ney.:

2, NOTES Yzpa red by h

Date,

y [g-J 3iccked by g d a --f '

Date j

p7

%a test subjected the valve motor operator to a transient of 250'F and 39.7 psia for 30 minutes, followed by a cooldown to 120'F in 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />. %e valve motor operator was then exposed to a second transient of 250*F and 39.7 psia for 22 houre, then a cooldown to 200*F and 24.7 psia which was maintained for 15 days. We temperature in Room 314 peaks at 221*F in 1.55 acconds. We pressure in Room 314 peaks at 19.76 psia in.086 seconds. We temperature and pressure in Room 314 return to ambient conditions af ter 8 minutes.

Based on this inf ormation, it can be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result f rom the postulated IIEIR.

Since the valve motor operator remained operable throughout the test, it can be concluded that the valve motor operator will remain f unctional during and af ter j

exposure to the accident environment which would result f rom the postulated flEIB.

(Reference C-314)

I 1

l

.I I

i 4

h e

i i

/m r

rh

()

(v) fv Fccility: Lavic-Becca Unit 1 Dockst 50-346 SYSTEM CCMPCNENT EVALUATION WORKSHEET Index No.: 223H-010 Re v. :

2

/[!/[O Prepcred by:

Dater Check 2d by:

A& wow / Dater ///.J/d3 l

11 l EQUIPMENT DESCRIPTION ll ENVIRONMENT I

l l

1 l_

ll Parameter l Specification l Qualification DOCUMENTATION REF.

I Specificationl Qualification 'l Qualification l Outstanding l l

ll l

l l

l Method l

Items l

lSy1 time Containment Gas l l Operating l 1 Year l

1.1 Years l

F l

M-26 l Simultaneous l None l

I l

l Analyzer and Radiation ll Time l

l l

l V-24G l

Test l

l l

Monitoring ll l

l l

l

! Pltnt ID No MV50llA Note 1 l

l I

l l

Terrperature l 218.0 l

300.0 1

C-303 l

M-26 l Simultaneous l None l

l Conponent : Valve Motor ll

(*F) l l

l l

V-24G l

Test l

l i

)

l l

Operator ll l

l l

l l

l l

l Manuf teturer Limitorque ll l

l l

l l

l l

l l l Pressure l

17.16 l

84.7 l

C-303 l

M-2E-l Simultaneous l None l

lModel Number: SMB-000 ll(PSIA) l l

l l

V-24G l

Test l

l lO/N: 306244B ll l

l l

l l

l l

l ll l

l l

l l

l l

l Func tion : Operates Con-ll Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

l tsinment Atmosphere Mon-l l Humidity l

l l

l V-24G

{

Test l

l l itoring System Valve ll l P;nttration 71B ll_ (%)

l l

l I

l l

l l

l l

l l

l Accuracy : Spect N/A ll l

l l

l l

l l

l Demon: N/A ll Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

None l

lSarvica: Containment Air ll Spray l

l l

l l

l l

l Sanple Isolation ll l

l l

l l

l l

l valve ll l

l l

l l

l l

lLocItion s Auxiliary Bldg. l l l

l l

l l

l l

}

Rm. 303 ll Radiation l1.16 x 106 RADS l2.0 x 108

}

RADS l T

l M-26 l Sequential Test]

None l

ll IFlood Lsvel diev:

N/A ll l

V-24G l

l l

1 Above Flood Level N/A ll Aging l

40 Years i

40 Years l

I l

CAL-93 l Sequential Test l Hone l

t l

l l

ll l

l l

l l

Analysis l

l NEeded for ll l

l l

l l

l l

Hot Shutdown lX l ll l

l l

l l

l l

l l Subme rgence l N/A l

N/A l

N/A l

N/A l

N/A l

None l

Cold Shutdown lY l Fl l

l l

l l

l l

ll l

l l

l l

l 1

N

]

(

/)

/

',3ft-010A F.:cility : Davig-Dessa Unit 1 SYSTDi COMPONENT EVALUAuON WORKSilEET Index No.:

22 bcket:

50-346 Rev.:

1_

Pr:pur:d by:

N Date N _f, JJ Jircked by: g g g _

IAnte

,,f(,2, gI l.

h test subjected the valve motor operator to a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120'F in 3.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

The valve motor operator was then subjected to a second transient of 300*F and 44.7 psia, which was maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for 24 days.

The temperature in Ibom 303 peaks at ?? o'F in 1.5 seconds. The pressure in Room 303 peaks at 1716 psia in.038 seconds.

The cori itions in Roon d

303 return to ambient af ter 19 minutes.

Based on this inforination, it can be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result f rom a posti 1ated llEID. Since the valve motor operator remained operable throughout the test and functional af ter the test, it can be concluded that the valve motor operator will remain functional during and af ter exposure to the accident environment which would result f rom the postulated IIEIB.

(Reference C-303) b

(e)c-Be:

()

O O

LA Se Unit 1 Facility:

SYSTEM COMPOi_t EVALUATION WORKSHEET Dockst:

50-346 Index no.: 223H-011 Re v. :

2 Prepared by:

k ll!/!87 Date:

Cheeksd by:

M&.f)w//

Date y ////3 l

ll l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qualification l Outstanding l l

ll Parameter i Specification l Qualification I Specif ication Qualification Method l

Items l

7 l

ll l

l i

I l

lSystes
Containment Gas l l Operating l 1 Year l

1.1 Years l

F l

M-26 l Simultaneous l None.

l l

Analyzer and Radiation ll Time l

l l

l V-24C l

Test l

l 6

l Monitoring ll l

l l

l Note 1 l

l l

l Plant ID No.

MV50llB ll l

l l

l l

l l

l l l Temperature l 283.0 l

300.0 l

H, X

l M-26 l Simultaneous l None l

l Component : Valve Motor ll

(*F) l l

l l

V-24C l

Test l

l l

Operator ll l

l l

l l

l l

l ll l

l l

l l

1 l

l Mcnuf acture r: Limitorque l l Pressure l

52.0 l

84.7 l

G, X

l

.M-26 l Simultaneous l Hone l

l ll(PSIA) l l

l l

V-24C l

Test l

l l Modal Number SMB-000-2 ll l

l l

l l

l l

lO/N: 386244A ll l

l l

l l

l l

lS/N: 216446 l l Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

l Function: Containment ll Humidity l

l l

l V-24C l

Test l

l l Atmosphere Monitoring ll

(%)

l l

l l

l

' l System Valve Penetra-ll l

l l

l l

l l tion 68B ll l Boric Acid l

Boric Acid l

l M-26 l

l l

l Accurccy : Spec t N/A ll Chemical l

1800 ppm l

1800 ppm l

A l

V-24C l Simultaneous l None l

l Demon: N/A l l Sp ray l

pH 5.0 l

pH 5.0 l

l CAL-40 l

Test, l

l l l Se rvice Containment Air ll l

l l

l Note 2 l

Analysis l

l

' l Sartple Isolation l l l

l l

l l

l l

'l Valve ll l

l l

l l

l l

l Location
Containment ll Radiation l1.7 x 10 RADS l2.0 x 108 7

RADS l CAL-44 l

M-26 l Sequential Test l None l

il ll l

I l

V-24C l

l l

l Flood Level Elev: 572 '-2 "l l l

l l

l l

l l

' l Abova Flood Level Yes ll Aging 40 Years l

40 Years l

I l

CAL-93 l Sequential Test l None l

l Il l

l l

1 l

Analysis l

l I

lNasdad fors ll l

l l

l l

l l

1 l Hot Shutdown lX l ll l

l l

l l

l l

ll l l Subme rgencel 572'-2" l

603'-6" l

B l

M-23 l

N/A l

None l

il Cold Shutdown lX l ll l

l l

l l

l l

l ll l

l l

l l

l l

k Facility: Daw s-Desse Unit 1 SYSTEM COMPONENT EVALUAt40N WORKSIIEET Index No.: icudH-011A Mckst:

50-346 Rev. :

S IOTES Prspared by k

Date

/[ t PJ

{[ i _} J diccked by ggtO

/

Dtte

,L.

'ths test subjected the valve motor operator t.o a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120'F in 3.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The valve motor operator was then subjected to a second transient of 300*F and 44.7 psia, which was maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for 24 days. The temperature and pressure inside containment peak at 283*F and 52 0 psia in 17 and 50 seconds, respectively. At I hour the conditions are 214.7"F and 32.2 pain s at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> the conditions are 204*F and 29.46 psia s at 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> the conditions are 193.2*F and 27.08 psia; and at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> the conditions are 143*F and 18.03 psia. The conditions return to ambient in 7 days.

Iused on this infornation, it can be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result f rom a postulated IDCA.

Since the valve tr:otor operator remained

- operable throughout the test and functional af ter the test, it can be _ concluded that the valve motor operator will remain I

f unctional during and af ter exposure to the accident environment which would result f rom the postulated LOCA.

(Reference G, H, and X).

2.

CAL-40 qualifies components tested in a high pit boric acid spray to a pil value of 5.

I i

i 1'

4 1

f a

j

)

i i

j

\\g (f3)

(

)

l X

/

v Facility: L Jis-Becca Unit 1 Jock;t:

50-346 SYSTEM CmPCNENT EVALUATIm WORKSHEET Index tw.

_223H-012

!l!f2 Prepared by:

aad Dates Re v. :

2

heck 2d by: M a M "_ Dater n /s//3_

l ll l EQUIPMENT DESCRIPTION l}

l l

ENVIRONMENT l

l l

l ll Parameter l Specification l

DOCUMENTATION REF.

l Qualification lSpecificationlQualificationll Qualification l Outstanding l ll I

lSyntems Containment Gas l l Operating l

1 Year l

1.1 Years l

P l

M-26 l Simultaneous l None l

l Method l

Items l

l l

1 l

l l

Analyzer and Radiation ll Time l

l l

l V-24C l

Test l

l l

Monitoring ll l

l l

l Note 1 l

l l

lPltnt JD No.

MV50llD ll l

l l

l l

l l

l l lTerrperature l 283.0 l

300.0 l

H, X

l M-26 l Simultaneous l None l

l Couponint : Valve Motor ll

(*F) l l

l l

V-24C l

Test l

l l

Operator ll l

l l

l l

l l

1 ll l

l 1

l I

l

~l lMInuf teture r: Limitorque l l Pressure l

52.0 l

84.7 l

G, X

l M-26 l Simultaneous l None l

l l l (PSIA )

l l

l l

V-24C l

Test l

l l Modal Number SMB-000-2 ll l

l l

l I

l l

lO/N: 386244A ll l

l l

l l

l l

l ll Relative l

100.0 l

100.0 l

A l

M-26 l Simultaneous l None l

0 Function: Operates Con-ll Humidity l

l j

{

V-24C l

Test l

l

) tainment Atmosphere Mon-ll_ (%)

l l

l l

5 l

l itoring System Valve ll l

l l

l l

l

_l Penstralon 74B ll l Boric Acid l

Boric Acid l

l M-26 l

l l

Accurrcy: Spect N/A ll Chemical l

1800 ppm l

1800 ppm l

A l

V-24C l Simultaneous l None l

Demon: N/A l l Sp ray l

pH 5.0 l

pH 5.0 l

l CAL-40 l

Test, l

l S2 rvic3 : Containment Air ll l

l l

l Note 2 l

Analysis l

l Sanple Isolationll l

l l

l l

l l

Valve ll l

l Soc & tion: Containment ll Radiatio 1 l1.7 x 107 l

l l

l l

RADS l2.0 x 108 RADS l CAL-44 l

M-26 l Sequential Test l None l

l l_.

l l

l l

V-24C l

l l

lood Lewl Elev: 572 '-2 "l l l

l l

l l

l l

bova Flood Level: Yes ll Aging l

40 Years l

40 Years l

I l

CAL-93 l Sequential Test l None l

ll l

l l

l l

Analysis l,

l 4acdad fors ll l

l l

l l

l l

Hot Shutdown lXl ll l

)

l l

l l

l l l Subme rgencel 572'-2" l

597' l

B l

M-21 l

11/A l

None l

Cold Shutdown lX l ll l

l l

l l

l l

ll l

l l

l l

l l

.i

(

. Facility:

Divis-Ik ago Unit 1 SYSTDt CC;1PONENT EVALUATION WORKSHEET Index No.: 223H-012A x

i Jockat:

50-346 Itev. :

2, Preparad by b

Date,

_f( a 8f 3:ecked by:,4G//,jg Date,

er / 2///

L.

%s test subjected the valve motor operator to a transient of 300*F and 84.7 psia for 32 minutes, followed by a cooldown to 120*F in 3.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

Tlie valve motor operator was then subjected to a second transient of 300*F and 44.7 psia, whict. was maintained for 92 hours0.00106 days <br />0.0256 hours <br />1.521164e-4 weeks <br />3.5006e-5 months <br />, then a cooldown to 200*F and 24.7 psia, which was maintained for. 24 days. The temperature and pressuru inside containment peak at 283*F and 52.0 psia in 17 and 50 seconds, respectively. At I hour the conditions are

' 2L4.7*F and 32.2 psla; at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> the conditions are 204'F and 29.46 psia t at 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> the conditions are 193.2*F and 27.08 j

psla; and at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> the conditions are 143*F and 18.03 psia. W e conditions return to ambient in 7 days.

Dased on this information, it can be concluded that the laboratory test subjected the valve motor operator to an overal.'!

more severe environment than that which would result from a postulated IDCA.

Since the valve motor operator remained operable throughout the test and functional af ter the test, it can be concluded that the valve motor operator will remain f unctional during and af ter exposure to the accident environment which would result f rom the postulated IDCA.

H, and X).

(Ileference G, i

2.

CAL-40 tiualifles components tested in a high pH boric acid spray to a p!! value of 5.

I l

4 I

i i

i i

ii

)

i i

1

(O)

C' 8

SYSTEM C(MPWENTCJ) ATIN CORKSHEET Frcility: b J-Be2sa Unit 1 Ind.x 223H-013 Dockst 50-346 Re v. :

2 l[!'[P3 Prepsred by:

N Dates Checksd by:

M//t'udJ Dater

///$N.

i l ll l

l l

l lEQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qualification l Outstanding l l

l l Pa ramete r Specification l Qualification Specif ic ation iQualification Method Items l

l ll l

l lSystcm3 Contcinment Gas ll Operating l 1 Year l

1.1 Years l

F l

M-28 l Simultaneous l None l

l Analyzer and Radiation ll Time l

l l

l V-24G l

Test l

l l

Monitoring ll l

l l

l Note 1 l

1 l

l Plant ID No. MV50llE ll l

l l

l l

l l

l l lTenperature l 221.0 l

250.0 l

C-314 l

M-28 l Simultaneous l None l

l Copponent : Valve Motor ll

(*F) l l

l l

V-24G l

Test l

l l

Operator ll l

l l

l l

l lMinuf teturer Limitorque ll l

l l

l l

l l

l l l Pressure l

19.76 l

39.7 l

C-314 l

M-26' l Simultaneous l None l

lModel Number: SMB-000-5 ll(PSIA) l l

l l

V-24G l

Test l

l ilO/N: 382120A ll 4

l l

l l

l

' l S/N: 207542 ll l

l l

1 l

l l Function : Operates Con-ll Relative l

100.0 l

100.0 l

A l

M-28 l Simultaneous l None l

l tainment Atmosphere Mon-l l Humidity l

l l

l V-24G l

Test l

l l itoring System Valve ll

(%)

l l

l l Psnetration 43B ll

[

i I

l I

l l

l Accuracy : Spect N/A ll l

l l

l l

l l

,l Demon: N/A ll Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

Hone l

) l Sarvice s Containment Air l l Sp ray l

l l

l l

l l

l Sanple Isolation ll l

l l

l l

l l

l Valve ll l

l l

l l

l l

,l Location: Auxiliary Bldg.ll l

l l

l l

l l

l Rm. 314 ll Radiation l1.0 x 10 RADS l2.0 x 107' RADS l T

l M-28 l Sequential Test l None l

6 l

ll l

l l

v-24G l

l l Flood Level Elev:

N/A ll l

l l

l l

lAbova Flood Level: N/A ll Aging l

40 Years l

40 Years l

I l

CAL-93 l Sequential Test l None l

l ll l

l l

l l

Analysis l

l lN udad fors ll l

l l

l l

l l Hot Shutdown

,l x l ll l

l l

l l

l l

tl l l Subme rgencel N/A l

N/A l

N/A l

N/A l

N/A l

None l

l Cold Shatdown lX l ll l

l l

l l

l l

4 l

ll l

l l

l l

l l

[k ]/

\\

ceility: DaDru-Desse Unit 1 SYSTEM COMPONENT EVALUk24b WORKSHEET Indax No.: h.H-013A ackst:

50-146 Riv.:

f repared by b

Date ll t pl hscked byr, g g g g tute y

%e test subjected the valve motor operator to a transient of 250*F and 39.7 psia for 30 minutes, followed by a cooldown to 120*F in 1.5 houns.

The valve motor operator was then exposed to a second transient of 250*F and 39.7 psia for 22 hours2.546296e-4 days <br />0.00611 hours <br />3.637566e-5 weeks <br />8.371e-6 months <br />, then a cooldown to 200*F and 24.7 psia which was maintained for 15 days. The temperature in Room 314 peaks at 221*F in 1.55 seconds. The pressure in Room 314 peaks at 19.76 psia in.086 seconds. The temperature and pressure in Room 314 return to ambient conditions after 8 minutes.

Based on this inf ormation, it cara be concluded that the laboratory test subjected the valve motor operator to an overall more severe environment than that which would result f rom the postulated HEIB.

Since the valve motor operator remained j

operable throughout the test, it can be concluded that the valve motor operator will remain functional during and af ter 1

exposure to the accident environment which would result f rom the postulated HEIB.

(Ref erence C-314) 5 J

3

)

4

(3

/

J

)

Ftcility:(N2Vic-BecaoUnit1 Docket:

50-346 SYSTEM COMPONENT EVALUATION NORKSHEET Ptspared by:

Index No.: _223H-014 Chsi:ked by:

. J9"E C B _- / Date:

2 Date:

/

2 Rev.:

///-Vr3 l

il IEQUIPMENT DESCRIPTION l l_.

l_

ll_ Parameter i specification l Qualification ISpecificatio l ENVIRONMENT I

I i

l

~

ll DOCUMENTATION REF.

i

~1 i

_l Qualification l Outstanding l ISystem: Containment Gas I

n 0ualificationi Iloperating i 1 Year i

40 Years i

Note 1 l

Note 2 l

Analysis l

None i

I I

Method 1

Items l

Analyzer & RadiationflTime I

l I

i Monitoring I l_

I I

~

1 l Plant ID No. MV50300 i

i i

i ll l

i i

1 llTemperature!

l I

i l

i i

l Component: Valve Motor ll

(*F) l Exempt I

C-303 i

Note 3 i

N/A l

None l

218.0 i

l i

l l

_l l

I Operator il i

l l

IMKnufacturer: ITT Generaill i

l l

l t

l I

Controls llPressure l

l 1

l I

1 i

17.16 l

Exempt I

C-303' l

Note 3 l

N/A l

None l

l I

l l

IModel Number:

ll(PSIA) l l

l

_l NH-95 ll_

l l

t 11 i

l 1

1 l

IFunction: Operates Con-llRelative i

100.0 i

Exempt l

A l

Note 3 i

N/A l

None l

I I

l I

I l

I tainment Atmospherell Humidity I

i l

i

__l i

i I

Radiation Monitor I(_ (%)

1 l

i 1

Inlet Valve il I

i i

l l

lAccuracy: Spec:

N/A 11 l

I l

l I

l l

l l

I 1

Demon: N/A llChemical i

N/A 1

N/A l

N/A I

N/A l

N/A I

None l

l l

I Isarvice: Containment ilSpray i

l i

_i l

1 Atmosphere Radiationll I

1 l

I l

l Monitor Inlet Valvell_

I i

i I

i ILocation: Auxiliary Bldg.ll i

I i

I I

l i

I Rm. 303 l

_t 1

l l1 Radiation I 9x102 l

i l

I l 1.0x107 l

CAL-86 l

I l l_

l Rads l T

l Note 2 l

Analysis l

None l

IFlood Level Elev:

1 N/A ll i

I IAbova Plood Level:

I l

I l

N/A llAging I

40 Years 1

40 Years l

I I

Note 2 l

Analysis l

None I

I l

I 1

ll I

CAL-86 I

l (Ne:d:d for:

l 1

I l l_

l I

I l Het Shutdown 111 1I I

l i

I 1

l 1

I 1

lISubmergencel I

I 1

g) Cold Shutdown ill Il l

l I

N/A l

N/A l

N/A l

N/A I

N/A I

None I

i 1

L 1

i l

_Il -

1 l

I l

I l

I l

i l

1 1

p m

k (p)

, FF.cility: Lavis-Basse Unit 1 SYSTEM COMPONENT kw.JUATION WORKSHEET IndIx Last 223H-014A Dockst:

50-346 Rev.:

2

/!I3 N

Date Ptsparzd by:

i Chicked by: Mm h Date ///,V /3 1.

One year operating time is used as a conservative maximum specification.

2.

Msterials evaluation conducted. Materials sensitive to radiation and/or thermal aging summarized on attached evaluation.

3.

This component is a two position hydramotor actuator controlling the containment atmosphere radiation monitor RE5030 inlet valve. The actuator is energized by means of local control switch NHS50300 and local test pushbutton switch NV50300. This actuator is a two position (full open, full closed) component with positive spring return and is designed so that actuator failure results in closure of the valve. Actuator control is by means of an internal limit switch. The actuator is exempt from qualification because it does not perform a safety-related function in the harsh environment resulting from a high energy line break. Loss of power will cause the actuator / valve to return to its closed position. The containment atmosphere radiation monitoring system is used to detect radiation in the containment atmosphere. This system would not be required to mitigate a high energy line break in Room 314. Since this system would not be required to mitigate a high energy line break, failure / closure of the actuator / valve would not degrade any other safety-related functions or mislead the operator. Containment radiation monitor RE50290 located in Room 314 (not exposed to a harsh environment due to HELB in Room 303) would also be available for cor.tainment atmosphere radiation monitoring.

i 1

I

O U

F cilit :~ Davis-Bacsa Unit 1 Docket:

50-346 COMPONENT MATERIALS EVALUATION SHEET Prcpared by:

Index No.: 223H-014B Date: _

d Rev.:

Chicked by:

h h ___ Date: H/.V/3 2

l Plant I.D. No.:

l MV50300 Component:

Manufacturer:

_ITT General Controls Damper Motor Operator I

Model No.:

[

(_

NH-95 l

I l_

Parts List

  • l THERMAL AGING I

I I

Materials List 1

Qualification RADIATION i

I Insulation i

I Reference 1 l

i I Valve Seat Ring Kapton (Polyimide) i Qualification l

l Reference I l

40 Years 9 288'F i CAL-86 1

1x107 l

I i Polyimide l O-Ring Seal i

1 l Saal Nitrile Rubber (BUNA-N) 40 Years 9 288'F i CAL-86 1

1x107 l CAL-86 l

Rads l

40 Years 9 104*F l

i Polymyte Rads l CAL-86 1

1.5x107 l CAL-86 l

l IGreater than 40 Years I Diaphragm l

9 122*F Rads I CAL-86 I

1 CAL-86 l

1.0x107 I

i Nylon Coated BUNA-N l

l Rads l CAL-86 l

I 40 Years 4 104*F 1 CAL-86 l

1.5xlO Rads I CAL-86 I

l I

l i

l i

i I

i i

I i

I I

i i

l I

i i

i I

I I

l I

I

'. I I

I l

i 1

1 1 I

I I

I l

I

!l I

I I

I I

I

'I I

I I

I I

i I

I I

i I

I I

I I

I I

I I

I i

I I

I I

I I

i l

I i

I I

I

'I I

i I

i I

I i

i i

l l

I I

iI 1

I I

I l

l I

1 I

I I

i I

I I

l I

I I

I I

I I

Material &

I Parts List

Reference:

I I

I M-29, M-30, M-31, ROC-21 A, i

i and V-21A

  • Only non-metallic parts are listed by radiation.

Metallic parts are not considered to be sensitive to th ermal aging and are not affected

( )'

h)

(

[

(

Ftcility: Dsvis-Bezco Unit 1 SYSTEM CG4PONENT kJ1UATION WORKSHEET Indix L : 223H-015 Dockst 50-346 Rev. :

2 Prepered by:

Dates I

Checksd by a h_

A J Date: 19/.47/J l

ll l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRONMENT DOCUMENTATION REF.

l Qualification l Outstanding l l

ll Parameter l Specification '

Qualification Specif ication Qualification Method l

Items l

l ll l

l l

l l

l Systems Containment Radi-l l Operating l 1 Year l

36.5 Years l Note 1 l

Note 2 l

Analysis l

None l

l ation Monitoring ll Time l

l l

l l

l l

l ll l

l l

1 l

l i~ l Plant ID No. PSH5029 ll l

l l

l l

l l

l lTenperature l 221.0 l

Exenpt l

C-314 l

Note 3 l

N/A l

None l

l Component : Pressure ll

(*F) l l

l l

l l

l l

Switch ll l

l l

l l

l l

l ll l

l l

l 1

l lManuf teturer: Static-O-l l Pressure l

19.76 l

Exengt l

C-314 l

Note 3 l

N/A l

None l

l Ring ll(PSIA) l l

l l

l l

l l Modal Numbert ll l

l l

l l

l i

l 12V2E4M2CTTX4 ll l

l l

l l

l l

l ll Relative l

100.0 l

Exenpt l

A l

Note 3 l

N/A l

None l

l Function: Permissive ll Humidity l

l l

l l

l l

l Interlock ll (t )

l l

l l

l l

l l Accu rtcy : Speca N/A ll l

l l

l l

l l

l Demon N/A ll l

l l

l l

l l

l ll Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

Hone l

lSarvice: Containment l l Sp ray l

.l l

l l

l l

l Channel 2 Post-Accident ll l

l l

l l

l l

l Radiation Monitor Line l l l

l l

l l

l ll l

l I

l CAL-85 l

l l

i l Location:

Aux. Bldg.

ll Radiation l1.0 x 106 RADS l4.0 x 106 RADS l T

l Note 2 l

Analysis l

None l

l Rm. 314 ll l

l l

l l_

l l Flood Level Elev N/A ll l

l l

l CAL-85 l

l l

l Abova Flood Level N/A ll Aging l

40 Years l

36.5 Years l I

l Note 2 l

Analysis l

None l

l ll l

l Nde 4 l

l l

l l

lNasdsd for:

ll l

l l

l l

l Hot Shutdown lX l ll l

l l

l l

l l

l l Subme rgence l N/A l

N/A l

N/A l

N/A l

N/A l

None l

l Cold Shutdown lX l ll l

l l

l l

l l

l ll l

l l

l l

l l

s a

Facility: Davic-Be:ss Unit 1 SYSTEM CDtPONENT EVALUATION WORKSHEET 3ockst 50-346 Index No.: 223H-015A Rev. :

2 Prepared by:

Date A

'~hecktd by: M M Af Date ff}s/ [3 i

l.

Ons-year operating time is used as a conservative maximum specification.

2 M
terials evaluation conducted.

Materials sensitive to radiation and/or thermal aging summarized on attached evaluation 3.

This component is a pressure switch that provides overpressurization protection for the containment po t monitor.

The harsh environment seen by this component is due to a main feedline break.

s -accident radiation prassure but is located outside containment.

This component monitors containment sealed sensing element within the switch.

A sensing line allows containment atmospheric pressure to be measured by a.

This sensing element actuates the switch mechanism.

.l this device will be exposed to the LOCA environment.

None of the internals of The sensing line is normally filled with air and, during a LOCA, air in the sensing line will be compressed by the inside containment steam-air pressure mixture rise but there will be n the flow in the sensing line and no steam-air-chemical spray mixture will enter the device.

4 Tha switch is exempt f rom qualification in the harsh steam environment because the containment po t 4

j monitor is only needed during loss of coolant accidents.

s -accident radiation switch f ailure will not degrade other safety-related functions.Since the monitor will not be used during a high energy line

break, i

so its f allure will not mislead the operator.

The switch does not provide an indication f unction 4.

Materials and/or components sensitive to thermal aging will be replaced as per maintenance assure that associated component will maintain functional cperability in harsh environner'.a.and replacement schedules to i

1 1

4 i

1 5

i l

Facility: Dnvic-Becca Unit 1 Docket:

50-346 C04PONENT MATERIALS EVALUATION SilEET Index Mo.: _223H-015B Reiv.

2 Prepared by:

Dates h

Checked by:

h-s Dater / //485 l

Plant I.D. No. :

PSH5029 Component :

Pressure Switch 1

Manuf actu re r Static-O-Ring l

Model No. :

12V2E4M2CTTX4 I

I 1

I I

THERMAL AGING I

RADIATIO 4 i

l I

Parts List

  • I Materials List Qualification l Reference i Qualification i Reference i i

i i

i i

i i

i Dtek-up Diaphragm l Silicone Rubber i

40 Years @ 302'F i

CAL-85 l 7.0 x 106 I

O-Ring i

BUNA-N RADS l

CAL-85 I I

40 Years 0 104'F I

CAL-85 l 1.5 x 107 i

Cover Gasket i Neop rene 1

36.5 Years 9 104'F 1 CAL-05 I 7.0 x 106 2

RADS I

CAL-85 1 l Elsctrical Insulation i Nylon i

40 Years 0 122*F l

CAL-85 1 4.0 x 106 RADS I

CAL-85 l l Switching Element Case i Heat Resistant Phenolic I

Greater then l

CAL-05 1 1.0 x 107 RADS I

CAL-85 l l

End Cover l

RADS I

CAL-85 l I

40 Years @ 230*F I

I I

I I Wira Leads l

l

\\

l I

l I

I Theraq)lastic I

40 Years 9 140*F i

CAL-85 1 8.0 x 106 lI Terminal Block I

Insulation (PVC) l I

I I

I RADS I

CAL-85 I l Stritch Element Plunger i General Purpose Phenolic l 40 Years @ 230 'F l

CAL-85 l 1.0 x 107 i i I Heat Resistant Phenolle 1

40 Years @ 230*F l

CAL-85 l 1.0 x 107 RADS l

CAL-85 l I

I I

RADS l

CAL-85 l i

1 I

I I

I ll 1

I l

i I

1 1

I I

l l

ii i

i l

l I

I

1 I

I I

I I

I

'I I

I I

I I

I I

i i

I I

i l

l I

I I

I I

I I

I I

I i

I I

I I

I 1

1 I

I I

i i

l i

l i

i i

l i

I i

I I

l I

ii l

I I

I I

I i

i l

i l

MIterials & Parts Reference List V-27A, V-37B, ROC-37A, ROC-37C, ROC-37D

  • Only non-metallic parts are listed.

Metallic parts are not considered sensitive to thermal aging and are not affected by radiation.

V

~~

/.

(%;j

'v Itcility: Davic-Be;00 Unit 1

\\

Jock;,t :

50-346 SYSTEM CCMPONENT EVALUATION WORKSHEET i

Index ?lo.: 223H-016 Prepared by:

Date

((

Re v.

2 2 heck;d by:

Mf E__

Dater fr/i,fn l

ll l EQUIPMENT DESCRIPTION ll l

l ENVIRONMENT l

1 l

ll Parameter l Specification l Qualification DOCUMENTATION REF.

I l

l l

Specification l Qualification ll Qualification l Outstanding l ll l Systems Containment Radi-ll Operating Method l

Items l

l l

1 l

l l

1 Year l

36.5 Years l Note 1 l

Note 2 l

Analysis None l

l ation Monitoring ll Time l

l l

l l

l l

l l1 l

l l

l l

l l

i lPltnt ID No. PS!!5030 ll l

l l

l l

l l

)

l i

l lTenperature l lCopponsnt s Pressure ll

(*F) l l

l l

l l

l 218.0 l

Exempt l

C-303 l

Note 3 l

N/A l

None l

l Switch ll l

l l

l l

l l

\\

l ll 1

l l

l l

l l

lMinuf ccture r: Static-O-ll Pressure l

17.16 l

Exempt l

C-303 l

Note 3 l

N/A l

None l

l Ring l l (PSIA )

l l

l l

l l

l l Modal Number:

ll l

l l

l l

l l

l 12V2E4M2CTTX4 ll l

l l

-l l

l l

l l l Relative l

100.0 l

Exempt l

A l

Note 3 l

N/A l

None l

l Function: Permissive l

ll Humidity l

l l

l l

l l

Interlock ll

] Accuracy: Spec:

N/A ll__

(4 )

l l

l l

l l

l l

l l

l l

l l

l Demon N/A ll l

l l

l l

l l

l l l Chemical l

N/A l

N/A l

N/A l

N/A l

N/A l

None l

S2rvica: Containment llSp ray l

l l

l l

l l

I Chrnnel 1 Post-Accident ll l

l RIdistion Monitor Line ll l

l l

l I

l I

l ll l

l l

l l

l Loc & tion:

l Auxiliary Bldg.ll Radiation l1.16 x 106 l

l CAL-85 l

l l

Rm. 303 l]

RADS!,4.0 x 106 RADS l T

l Note 2 l

Analysis l

None l

71ood Lovel Elev:

l l

l l

l l

l N/A ll l

l l

l Above Flood Level N/A llA ll ging l

40 Years l

36.5 Years l I

l Note 2 l

Analyals l

None l

CAL-85 l

l

__I l

l Note 4 l

l l

l l

Nad:d fors ll l

l l

l l

I I

Hot Shutdewn lXl ll l

l l

l l

l l

14 Subme rgencel N/A I

N/A l

N/A l

N/A l

N/A l

None l

Cold Shutdown lxl ll l

l l

l l

l l

ll l

I l

l l

l l

l

f%

\\

Facility: D ic-BeJco Unit 1 SYSTEM CCMPONENT EVALUATION WORKSHEET Dockit:

50-346 Index No.: _223H-016A Re v. :

2 Prepcred by:

Date 1/

' Checksd by: h s 6--

g Date

/ /g i 1.

On e-year operating time is used as a conservative maximum specification.

2 Materials evaluation conducted.

Materials sensitive to radiation and/or thermal aging summarized on at. cached evaluation.

3.

This component is a pressure switen that provides overpressurization protection for the containment post-accident radiation monitor. The harsh environment seen by this component is due to a main feedline break.

This coas>onent monitors containment pressure but is located outside containment.

A sensing line allows containment atmospheric pressure to be measured by a cacled sensing element within the switch.

This sensing element actuates the switch mechanism. None of the internals of this device will be exposed to the LOCA environment.

The sensing line is normally filled with air and, during a LOCA, the

)

air in the sensing line will be compressed by the inside containment steam-air pressure mixture rise but there will be no flow in the sensing line and no steam-air-chemical spray mixture will enter the device.

The switch is exempt f rom qualification in the harsh steam environment because the containment post-accident radiation monitor is only needed during loss of coolant accidents.

break, switch f ailure will not degrade other safety-related functions.Since the monitor will not be used during a high energy line so its f allure will not mislead the operator.

The switch does not provide an indication f unction 4

Mitsrials and/or components sensitive to thermal aging will be replaced es per maintenance and replacement schedules to ecsure that associated component will maintain functional cperability in harsh environments.

i I

i i

Os

)

Facility: D vic-Be2ca Unit 1 Docket:

50-346 CGtPONENT MATERIALS EVALUATION SHEET Index No.: 223H-016B Prepared by:

Rev.:

2 Dater /

Checked by:

&? A Date: J/Jh i

Plant I.D. No.:

PSH5030 I

Component : _

Pressure Switch Manuf acturer Static-O-Ring I

Model No..:

l; 12V2E4M2CTTX4

)

l_

l l

!l_

Parts List

  • I Materials List l

Qualification l Reference !

Qualification i Reference I I

l THERMAL AGING I

l RADIATIGi l

I I Brck-up Diaphragm l Silicone Rubber 1

40 Years 9 302*F l

CAL-85 1 7,0 x 106 I

I I

I O-Ring i

BUNA-N I

I l Cover Gasket l Neop rene I

40 Years 9 104*F l

CAL-85 l 1.5 x 107 RADS l

CAL-85 I l

Electrical Insulation i Nylon l

36.5 Yrs 9 104*F l

CAL-85 1 7.0 x los RADS l

CAL-85 l

\\\\ Switching Element Case i Heat Resistant Phenolic l

Greater then I

CAL-85 l 1.0 x 107 1

40 Years 9 122*F l

CAL-85 l 4.0 x 106 RADS I

CAL-85 1 l

and Cover RADS l

CAL-85 l l

l Wire Leads l

l 40 Years 9 230*F I

i RADS l

CAL-85 l l

l l

l l The rscplastic l

40 Years 9 140*F l

CAL-85 l 8.0 x 106 l

l l Terminal Block l

Insulation (PVC) 1 l

l 1 l Switch Element Plunger i General Purpose Phenolic l 40 Years 9 230*F I

CAL-85 l 1.0 x 107 RADS I

CAL-85 l

} l l

1 I

l l Heat Resistant Phenolic l

40 Years 6 230*F l

CAL-85 l 1.0 x 107 I

RADS l

CAL-85 l I

I I

RADS I

CAL-85 l I

I

(

I i

l i

i i

l I

l I

I

.I l

I I

I l

i i

l I

l I

I I

I I

I I

!I I

I I

I I

I I

I I

I I

I I

I 4

I I

I I

I I

I I

I

I I

I I

I I

I I

I I

tI I

I I

l i

I l

l l

l I

I I

l i

I i

l 1

1 I

$ Materials & Parts Reference List 1

I I

I V-37A, V-37B, ROC-37A, ROC-37C, ROC-37D

  • Only non-metallic parts are listed.

Metallic parts are not considered sensitive to thernal aging radiation.

and are not affected by

k l Fccility:

L.,~

s-Besse Unit 1 SYSTEN COMPONENT weALUATION WORKSNEET h

Dockst 50-346 Index No.: 223N-019 Rev.:

2 Prepared by:

'f f Dater

/ 8/

j Checkad by:

AL*,o f b Jf Dates

  1. f
  • d 4

?

i l Il l

l l

l l EQUIPMENT DESCRIPTION ll ENVIRONMENT l

DOCUMENTATION REF.

l Qualification l Outstanding l i

l l} Parameter Specification Qualification Specification Qualification!

Nethod Items l

[

i i l ll l

l i

I l

lSystsm: Containment Gas ll Operating l 1 Year l

Note 2 l

Note 1 l

N/A l

N/A l

Mone l

J

! l Analyzing & Radiation ll Time l

l l

l l

l l

l Monitoring ll l

l l

l l

l l

[

l 11 l

l l

1 l

l

-l l

< IPlant ID No. RE2387 llhaperaturel 283.0 l

Note 2 l

N, X

l N/A l

N/A l

None l

I l ll

(*r>

l l

l l

l l

l l Component: Radiation ll l

l l

l l

l

[

7 l

Monitor ll l

l l

l l

l l

l ll Pressure 1

52.0 l

Note 2 l

G, X l

N/A l

N/A l

Mone l

INanufacturer: Victoreen ll(PSIA) l l

l l

l l

l l

ll l

l l

l l

l l

} lNodel Number: 841-1 ll l

l l

l l

l l

l

)

ll Relative l

100.0 l

Note 2 l

A l

N/A l

N/A l

None l

l llNumidity l

l l

l l

l l

! l Function: Nonitors ll (t) l l

l l

l l

l

! l Radiation ll l

l l

i l

l l

{ l Accuracy Spec:

N/A' ll l Boric Acid l

l l

l l

l l

Demon N/A ll Chemical l

1800 ppm l

Note 2 l

A l

N/A l

N/A l

Mone l

t l llSpray l

pN 5.0 l

l l

l l

l IlSarvice Containment Wide ll l

l l

l l

l l

l l Range Radiation Ch. 1 ll l

l l

l l

l l

I ll l

l l

l l

l l

l lIocstions Containment ll Radiation l1.0 x 108 RADS l Note 2 l

A l

N/A l

N/A l

None l

t ll EL. 4 ll l

l l

l l

l l

' l Flood Level Elev N/A ll l

l l

l l

l l

l l Abova Flood Invel Yes ll Aging l

40 Years l

Note 2 l

I l

N/A l

N/A l

None l

l ll l

1 l

l l

l l

?

lNetdsd fort ll l

l l

l l

l l

l Not Shutdown lxl ll l

l l

l l

l l

l l l Submergence l 572'-2" l

603'-0" l

B l

AD l

N/A l

None l

l Cold Shutdown lX l ll l

l l

l l

l l

jl ll l

l l

l l

l l

l t

i i

t l

l

Freility: L2-Becaa Unit 1 SYSTEM COMPONENT ATION WORK 5HEET Index C ~ A 2?H-019A Dock;ts 50-346 Rev.:

2 Prep 2rsd by:

J Date f 8.I

~

ch;ck d by:.ce ').vo D, 47 Date - ' : sh 1.

Ona year operating time is used as a conservative maximum specificatten.

2.

A qualified, safety-related, wide-range radiation monitoring system has been installed (see 302H-048 and 302H-049). This equipment merely acts as an unqualified backup.

W

=

)

Facility dio-DBC3e Unit 1 h

Dockst 50-346 SYSTEM COMPONENT EVAINATION NORKSHEET Index No.: _223H-020 Prspared by: _

Date:

Rev.

d '

2 Checksd by:

,,t/, e ( i..,/ /

Datea __

  1. M f/?N.3

'l iI lEQUIMtENT DESCRIPTION ll l

l ENVIRONMENT l

1

-l L

i l

DOCUMENTATION REF.

l_

ll Parameter l Specification ! Qualification specification lQualificationIl Qualification l Outstanding l ll l

l I

l l

l Systems Containment Gas l l Operating l 1 Year l

Note 2 l

Note 1 l

N/A l

N/A l

Mone l

l 1

Method Items l

l Analyzing & Radiation ll Time l

l l

l l

l l

I 1

~l l

Monitoring ll l

l l

l ll l

l l

l l

l l Plant ID No. RE2389 l

l lTe-#-eraturel 283.0 l

Note 2 l

H, I l

N/A l

N/A l

None l

i l

l ll

<*r) l f

l

~j l Components Radiation ll l

l l

l l

l l

l l

l l

l l

l Monitor ll l

l l

l l

l

~l l

ll Pressure l

52.0 l

Note 2 l

G, X l

N/A l

N/A l

None l

l Manufacturer: Victoreen ll(PSIA) l l

l l

l l

l l

ll l

l l

1 lModel Number: 841-1 ll l

l l

l l

l l

l ll Relative l

100.0 l

Note 2 l

A l

N/A l

N/A l

Mone l

l l

l

~l ll Humidity l

l l

l l Function: Nonitors ll

(%)

l l

l l

l l

l Radiation ll l

l l

j l

lAccurEcy: Spect N/A ll l Boric Acid l

l l

l l

l l

1 l

Demon N/A ll Chemical l

1800 ppm l

Note 2 l

A l

N/A l

N/A l

None l

l l

~l l

lServica:

llSpray I

pn 5.0 l

l l

l l

l Containment Nidell l

l Ranga Radiation Ch. 2 ll l

l l

l l

l i

-l l

l l

l l

l l

ll 1

l l Location: Containevnt ll Radiation l1.0 x 108 1

l 1

l l

l RADS l Note 2 l

A l

N/A l

N/A l

None l

El. 4 ll l

l l

l l

l l

l Flood Level Elev:

N/A ll l

l l

l l

l l

lAbova Flood Level Yes ll Aging l

40 Years l

Note 2 l

I l

N/A l

N/A l

None l

l ll l

lNesded for ll l

l l

l l

1 ll Hot Shutdown lXl ll_

{

l l

l_

l l

l l

l l

l l

l l

)

~

ll Submergence l 572'-2" l

603'-0" l

B I

AD l

N/A l

None l

l

) Cold Shutdown lxl ll l

l l

l l

l l

1 ll_

l l

l l

l l

l I

i

Pccility: L v )-Becco Unit 1 SYSTEM COMPDNENT TION WORKSHEET Index NL,/223H-020A Dock;t 50-346 Rev.:

2

'h' Date 8 N Pr:ptrsd by:

Ch;ck:d by: p

r.,,,9),,f Date

~5e 1.

Ons year operating time is used as a conservative maximum specification.

2.

A qualified, safety-related, wide-range radiation monitoring system has been installed (see 302H-048 and 302H-049). This equipment merely acts as an unqualified backup.

e

n

/e

)

N /

J Fccility:~ Davic-Brace Unit 1 Docket:

50-346 SYSTEN COMPONENT EVALUATION WORKSHEET Prepared by:

Index No.: _223H-023_

Date:

I Rev.: _

2 Ch;cked by; A H_ -

N,/A,/C i_.

Date:

11 IEQUIPNENT DESCRIPTION IL i

l ENVIRONMENT I L Parameter i Specification l l

I I

DOCUMENTATION REF.

i Qualification ISpecificationlOualificationi__l Qualification i Outstanding il Il ISystem: Containment Gas llOperating i 1 Year i

Exempt i

Note 1 I

Note 2 l

Analysis l

None I

i I

I Nethod 1

Items i

Analyzer and RadiationiITime I

l I

I l

I I l_

l l

I l plant ID No. AE5027 i

I i

ll 1

I l

l I

l IlTemperaturel l

I 1

IComponent: Gas Analyzer ll

(*F) l Exempt i

C-304 l

Note 2 i

Analysis l

None i

208.0 i

1 I

1

_I I

I

(

l 11_

I l

l INEnufacturer: Delphi lI l

I I

I l

1 i

l i

i l

l ll Pressure i

15 83 1

Exempt l

C-304 l

Note 2 l

Analysis i

None l

l I

l

__ I l Nods 1 Humber:

ll(PSIA) l 1

BIA-1B11D ti l

i i

l I

i l

I Il l

l I

l I

i 1

I l

llRelative i

100.0 l

Exempt i

A l

Note 2 l

Analysis l

None IFunction: Nonitor H 1

I I

_I 2

IIHumidity

[

i I

Gas l

I I

l l_

(t) l 1

il I

1 i

I 1

(Accuracy: Spec:

N/A

((

l I

I l

I I

I t

I I

I Demon: N/A ll Chemical i

N/A l

N/A i

N/A l

N/A I

N/A I

None i

l i

_I i

l l

llSpray i

l I

lSarvice: Nonitor H2 Il I

l cas I

l l

I I

l ILocation:

il I

I l

Auxiliary Bldg.Il I

I l

l l

I I

l Rm. 304 l

I I

l I

I l

l1 Radiation 1 627 RADS l

Exempt l

AV, T l

Note 2 l

l l

l l

_I ll 1

1 l Flood Level Elev:

N/A ll I

IAbova Flood Level:

l l

l l

Analysis i

None i

N/A IIAging i

40 Years l

Exempt l

I l

Note 2 i

I 1

I I

l I

I l

INesdsd for:

il l

I I

ll_

l I

l H:t Shutdown lil Il l

1 I

l I

Analysis I

NO"'

I l

l i

I l

l I

l ISubmergencel N/A l

N/A I

N/A l

N/A l

N/A l

None l

l Cold Shutdown 111 Il l

l

_l l

_l l_

I l

l

_11 1

l I

l I

l I

l I

l I

l

d s

FEcility:

w_. sic-Bress Unit 1

^

s SYSTEM COMPONENT EVALUATION WORKSHEET Dockst:

50-346 Index No.: 223H-023A 1

Rev.: _

2 Prspared by:

Date:

I Chscksd by: W h-M/

Date:

/4 /n i

1.

One-year operating time is used as a conservative maximum specification.

2.

This equipment is considered exempt from qualification for the following reasons:

The gas analyzer is only used to monitor hydrogen gas in the containment building subsequent to a LOCA and is therefore a.

I not required to operate after an HELB.

Therefore, this device is not required to be qualified for main feedline break condition.

b.

Subsequent to a LOCA, this device will be exposed to a total integrated dose of only 627 rada.

literature on the effects of radiation on non-metallic materials (WCAP-8587, Appendix C) demonstrates that materialsAnalysis of existin typical to power plant equipment construction would not be significantly affected by radiation doses less than 104 rads.

Therefore, the post-LOCA environment t.his equipment could be exposed to is considered mild.

10CFR50.49 does not require qualification of mild environment equipment.

i 1

I i

j 1

l I

l l

4

,i i

O Os N

h J

Fccility: D2Via-B22c2 Unit 1 Docket:

50-3C6 SYSTEM COMPONENT EVALUATION WORKSHEET Index No.: _223H-024 Prcpared by:

Ma!/ b 2

ney.:

Date:

8 Chicked by:

M R -M Date:

s //3_

l il l EQUIPMENT DESCRIPTION

( l_

i I

ENVIRONMENT I

_ll_ Parameter i Specification I Qualification DOCUMENTATION REF.

I I

I l

il i

ISpecificationloualificationi_l Qualification l Outstanding ISy2 tem: Containment Gas lIOperating i 1 Year l

Exempt l

Note 1

(

Note 2 i

Analysis i

None l

I I

Method i

Items

_I I

I I

l Analyzer and RadiationllTime l

I l

ll l

I lPlznt ID No. AE5028 l

l l

l l

ll l

l l

1 l

l l

l llTemperaturel 208.0 l

Exempt l

C-304 i

Note 2 i

Analysis i

None l

l l

l l

I IComponent: Gas Analyzer ll

('F) l l

l l

1 ll _

l l

l l

lMinufacturer: Delphi ll l

i I

I 1

l l

[

l I

llPressure i

15.83 i

Exempt l

C-304 l

Note 2 i

Analysis None Q

I l

l l

I ll(PSIA) l l

l l Modal Number: BIA-1BilD ll l

l l

l l

i l

I l

l l

ll 1

l l

l I

I ll Relative l

100.0 1

Exempt i

A l

Note 2 l

I I

I I

l 1

l Function: Monitor H2 ll Humidity i

I I

Gas l

I l l__ ( t )

i l

l 1

Analysis l

None l

I il i

I I

1 I

l Accuracy: Spec:

N/A ll l

i 1

I

_I I

I l

l Demon: N/A llChemical I

N/A i

N/A l

N/A l

N/A I

N/A l

None I

l I

i l

l 1

l IISpray i

l l

ISarvice: Monitor H I

2 II I

I I

I I

as il I

I I

I i ILocation: Auxiliary Bldg.ll I

I I

I l

I I

i I

I i l Rm. 304 llRadiation l 627 RADS l

Exempt l

AV,T l

Note 2 i

Analysis l

None I

I 1

l l

l I

l I l_

l l

l IFlood Level Elev:

2 l

N/A ll l

I I

lAbova Flood Level: N/A ll Aging l

40 Years l

Exempt i

I l

Note 2 l

Analysis i

None l

l I

l l

l I

I I

il I

l I

INatdsd for:

i ll_

l i

i i

I Hot Shutdown l X l ll l

l i

1 i

i l

' I 1

l l

l ISubmergence l N/A l

N/A i

N/A I

N/A l

N/A I

None l

I i

i l Cold Shutdown ill ll l

l l

l 1.

I l_

i l

l 1

i i

i I

l l

I I

t i

(-

k

/

'\\

/

FIcility: L Jc-B r:22 Unit 1 SYSTEM COMPONEN LUATION WORKSHEET Ind2x L s/ 223H-024A Dockst:

50-346 Rev.:

2 Prcp3rGd by:

Date:

I Chick d by: WhO c If Date: ///d//*)

1.

On?-year operating time is used as a conservative maximum specification.

2.

This equipment is considered exempt from qualification for the following reasons:

c.

The gas analyzer is only used to monitor hydrogen gas in the containment building subsequent to a LOCA and is therefore not required to operate after an HELB.

Therefore, this device is not required to be qualified for main feedline break condition.

b.

Subsequent to a LOCA, this device will be exposed to a total integrated dose of only 627 rads.

Analysis of existing literature on the ef fects of radiation on non-metallic materials (WCAP-8587, Appendix C) demonstrates that materials 4

typical to power plant equipment construction would not be significantly affected by radiation doses less than 10 rads. Therefore, the post-LOCA environment this equipment could be exposed to is considered mild. 10CFR50.49 does not require qualification of mild environment equipment.

-.