ML20063L080

From kanterella
Jump to navigation Jump to search
Refuel 6 ISI Summary Rept
ML20063L080
Person / Time
Site: Callaway 
Issue date: 02/11/1994
From: Housdan C
UNION ELECTRIC CO.
To:
Shared Package
ML20063K486 List:
References
NUDOCS 9403030196
Download: ML20063L080 (12)


Text

..

t Sheet I of 2 FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Cod, Rules

1. Owner Union Electric Co.. P.O. Box 149. St. Louis. MO 63166 i

(Name and Address of Owner)

2. Plant Callaway Plant. P.O. Box 620. Fulton. MO 65251 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Commercial Service Date 12/19/84
6. National Board Number for Unit NA
7. ComponentsInspected Manufacturer Components or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Reference the Callaway Refuel 6 Inservice Inspection Summary Report, the Owners N-3 Report, the Installers N-5 Report, and the N-5 Addenda 6 for the systems listed on sheet 2 of 2.

l l

I i

4 Note: Supplemental sheets in fwm of hsts, sketees, or drawing nuy be used provided (1) size is 8 % in. x 11 in.,(2)infornutwn in hena I throug.h 6 on this data report is included on each sheet, and (3) euh sheet is numbered and the number of sheets is remrded at the top of n t-9403030196 940211 PDR ADOCK 05000483 D

PDR

.~.-

+

t i

Sheet I of 2 (baci) -

t FORM NIS-I (back) 8.

Examination Dates 5-18-92 to J 1-22-93

9. Inspection Interval from 12-19-84 to 12-1K-94
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Reference the Callaway Refuel 6 Inservice Inspection Final Results.

IL Abstract of Conditions Noted.

Ref erence the Callaway Refuel 6 Insenice Inspection Final Results.

12, Abstract of Corrective Measures Recommended and Taken.

l Reference the Callaway Refuel 6 Inservice Inspection Final Results.

b We certify that the staternents made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Date February 11.

19 94, Signed Union Electric Co.

By Ih4 Owner l James M. Gloc" f

Certificate of Authorinition No. (if applicable)

N/A Espirati n D e N/A CERTIFICATE OF INSERVICE INSPECTION Li I, the undersigned, holding a valid commission issued by the National Board of Boiler and Picssure Vesse!

inspectors and/or the State of Province of _ Missouri and employed by.11.8 B I & l Co of 11artford.CT have ingected the components described in the Owners' Data Report during the period of 5-/r.ff to f/-2:2 ff and state that to the best of my knowledge and belief, the Owuct has perfomied examinations and taken corrective -

measures described in the Owners' Data Report in accordar.cc with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor this employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owters' Data Report. Furthennore, neither -

the Inspector nor this employer shall be liable in any manner for any personal injury or property damage or a loss of any k.ind arising from or connected with the inspections.

Date. February 11.

A 19_9_4.

Commissions N8 f4 f 9 A.

M /7 O38' n

w C'arroll E.11ousdan National Board, State Province and No.

t r

l' I

?

l l

Sheet 2 of 2 FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS

+

As required by the Provisions of the ASME Code Rules

1. Owner Union Electric Co. P.O. Box 149. St. Louis. MO 63166 (Name and Address of Owner)
2. Plant Callaway Plant. P.O. Box 620. Fulton. MO 65251 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Conunercial Senice Date 12/19/84
6. National Board Number for Unit NA
7. Components inspected SYSTEM N-5 SYSTEM NAME DESIGNATOR SERIAL NO.

Main Steam AB Ol77-AB-F Main Feedwater AE 0179-AE-F Auxiliary Feedwater AL 0207-AL-F Reactor Coolant BB 0276-BB-F Chemical and Volume Control BG 0306-BG-F Reactor Makeup Water BL 0096-BL-F Steam Generator Blowdown BM 0221-BM-F Borated Refueling Water Storage BN 0144-BN-F e

Fuel Pool Cooling and Cleanup EC 0128-EC-F Essential Senice Water EF 0285-EF-F Component Cooling Water EG 0256-EG-F Residual Heat Removal EJ 0229-EJ-F High Pressure Coolant injection EM Ol81-EM-F Containment Spray EN 0202-EN F Accumulator Safety injection EP 0203-EP-F Auxiliary Feedwater Turbine FC Ol37-FC-F Misc. Building HVAC GF 00,7-GF-F

-l

Sheet 2 of 2 (back) -

FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Union Electric Coi. P.O. Box 149. St. Louis. MO 631'66 (Name and Address of Owner)
2. Plant Callaway Plant. P.O. Box 620. Fulton. MO 65251 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Commercial Service Date 12/19/84
6. National Board Number for Unit '

NA

7. ComponentsInspected SYSTEM N-5 SYSTEM NAME DESIGNATOR SERIAL NO.

Fuel Building HVAC GG 0078-GG-F Control Building HVAC GK 0080-GK-F Auxiliary Building HVAC GL 0103-GL-F Containment Cooling GN 0141-GN-F Containment Hydrogen Control GS

. 0131-GS-F Liquid Radwaste HB Ol88-IU3-F Emergency Fuel Oil JE 0129-JE-F Compressed Air KA 0151-KA-F Containment Breathing Air KB 0123-KB-F Fire Protcetion KC 0047 KC-F Standby Diesel Generator (Piping)

KJ 0114-KJ-F l

Floor and Equipment Drains LF 0083-LF-F Nuclear Sampling SJ Ol35-SJ-F si m

r Refuel 6 ISI Summary ANtract j

February 11,1994 CALIAWAY REFUEL 6 INSERVICE INSPECTION ABSTRACT INTRODUCTION Inservice Inspections (ISI) on ASME Class 1, 2, and 3 components and piping wcre performed prior to 5

and during Refuel 6 at the Callaway Nuclear Plant. More specifically, this abstract covers ISI performed from May 18,1992. through November 30,1993. Refuel 6 is the second refueling outage in the third forty-month period of the first ten-year interval. The following topics are addressed in this abstract report:

Organizations responsible for ISI work during Refuel 6.

Inspection agency responsible for ISI at the Callaway Plant.

Codes Regulatory Guides, and NUREGs applicable to the Callaway ISI Program Plan.

Final reports contained in the Callaway Refhel 6 Insenice inspection Sununary Report.

ORGANIZATIONS RESPONSillt E FOR ISI The Union Electric organizations and outside vendors involved with ISI examinations during Refuel 6 are listed below.

NUCLEAR ENERGY SERVICES (NES): NES was responsible for development of the balance of plant (BOP) Callaway ISI Program Plan. In addition, NES was responsible for '

proculure development, procedure qualification, and perfotmance of manual non-destructive cuminations (NDE).

'i BABCOCK AND WILCOX NUCLEAR TECllNOLOGIES (BWNT): BWNT was responsible for procedure development, procedure qualification, and performance of

j automated and manual ultrasonic cxaminations on nine Reactor Coolant System centrifugally cast stamicss steel (CCSS) pipe welds.

CONAM NUCLEAR SERVICES: CONAM Nuclear Senices was responsible for procedurc development, procedure qualification, and performance of cddy current examinations on Steam Generators 'A' and 'D'.

UNION ELECTRIC QU ALITY CONTROL (UEQC): UEQC was responsible for identification of components to be visually examined during Refuel 6, procedure development, procedure qualification, and performance of visual cxaminations (e.g., VT-1. VT-2, VF-3, and VT-4) identified in the Callaway 151 Program Plan. UEQC was also responsibic for resiew of all visual examination data and results.

UNION ELECTRIC SYSTEMS ENGINEERING: Union Electric Systems Engineering was responsible for identification of welds and components to be examined by NES and BWNT, identification of steam generator tubes to be examined by CON AM, resiew of all vendor NDE procedures, field supenision of all vendor ISI activitics, resiew of all NDE final data and -

results, development and supenision of the ASME Section XI Ten-Year Hydrostatic Test '

Program, and for development and supervision of the ASME Section XI Repair / Replacement Program.

PageIof2

=_

Refuel 6 ISI Summarv

]

Abstmct

.l Echnmr3 11,1994 i

UNION ELECTRIC DESIGN CONTROL: Union Electric Design Control was responsible for disposition and final resolution of pipe and equipment supports not meeting the UEQC visual examination acceptance criteria.

INSPECTION AGENCY i

The inspection agency responsible for ISI duties as outlined in ASME Section XI was Hanford Steam Boiler inspection and Insurance Company (H. S. D.1. & L Co.).

1 CODES, REGULATORY GUIDES, AND NUREGS ASME Section XI,1980 Edition, Winter 1981 Addenda was the governing code for performance and selection of ISI examinations conipleted during Refuel 6. This code edition and addenda also governed the performance of augmented examinations required by the Callaway Final Safety Analysis Report. As specified in 10 CFR 50.55a. the 1974 Edition, Summer 1975 Addenda was used for component and weld selection for ASME Class 2 systems.

Specific regulations and/or NUREGs identified in the Callaway ISI Program Plan are listed below.

l NRC Standard Review Plan, Sections 3.6.1 and 6.6 (NUREG-OK90-1981)

_j NRC Regulatory Guide 1.14 NRC Regulatory Guide 126 t

NRC Regulatory Guide 1.83 NRC Regulatory Guide 1.147 t

CAI 1.AWAY REFUEL 6 ISI

SUMMARY

REPORT The Callaway Refuct 6 ISI Summary Report is a compilation of a number ofindividual repons. These reports are listed below.

s Nondestructive Examinations Performed by NES l

Visual Examinations Performed by Union Electric Quality Control Automated Ultrasonic Examinations on Reactor Coolant System Loop Welds Eddy Current Examinations on Steam Generators 'A' and 'D' Repair Replacement, and Modification Index (N-5 Addenda 6) r Each report or summary listed above identifies components and/or welds examined, date(s) of-examination, and the results of the examination. In addition, each report presents the procedures, j

equipment and consumable material used, personnel certifications, and equipment calibration records, where applicable.

I T15e " Owner's Data Report for Inservice inspections" (Form NIS-1) presents the Section XI required.

inforrnation by referencing existing documents. These reference documents are the Callaway Refuel 6 Inservice Inspection Summary Report, the Owner's N-3 Report, and the Installer's N-5 Report. Each of these documents is retained as a permanent record at the Callaway Nuclear Plant, j

'l l

i Page 2 of 2

-i

l Refuel 6 ISI Sununary Final Results February 11,1994 CALLAWAY REFUEL 6 INSERVICE INSPECTION FINAL RESULTS INTRODUCTION

-l This document summari/es insenice Inspections (ISI) performed at the Callawny Nuclear Plant during Refuel 6. In addition. general conditions noted during conduct ofISI and necessary corrective measures taken are summarued. For clarity, the ISI work has been subdivided into the following categories:

Nondestructive examinations (NDE) performed on Reactor Coolant and balance of plant systems by Babcock and Wilcox Nuclear Technologies (BWNT) and Nuclear Energy Senices (NES).

Visual examinations (e.g., VT-1, VT-2, VT-3, and VT-4) on piping, components, and supports performed by Union Electric Quality Control.

Steam gencmtor cddy current examinations performed by CONAM Nuclear Senices.

ASME Section XI repairs, replacements, and modifications performed by Union Electric.

NDE PERFORMED ON REACTOR COOLANT AND BALANCE OF PLANT SYSTEMS A total of 87 ultrasonic (UT),49 liquid penetrant (PT), and 13 magnetic particle (MT) examinations were performed on 123 Class I and 2 safety-related welds and components during Refuct 6. No rejectable indications wcre detected. A brief oveniew of the examinations performed and conditions noted is presented below.

REACTOR COOLANT:

I Reactor Coolant System loop piping was examined with the Babcock and Wilcox Nuclear Technologies (BWNT) advanced automated ultrasonic system, ACCUSONEX*. This advanced data acquisition and analysis system was used since the loop piping is fabricated of centrifugally cast stainless steel (CCSS). This material is inherently difficult to examine ultrasonically due to its very large grain site. ACCUSONEX*, combined with enhanced manual ultrasonic technigoes, were used to ensure the best possible examination.

A total of 4 loop 'A' wcids, 2 loop 'B' welds, and I loop 'D' wcld were examined using ACCUSONEX" The loop 'A' safety injection noulc-to<old leg wcld and loop 'C' residual heat removal recirculation nonle-to-hot leg wcld were examined by enhanced manual ultrasonic methods.

In addition, liquid penetrant examinations were perforrned on 10 Reactor Coolant System loop wcids.

No rejectable indications were detected.

REACTOR COOLANT PUMPS:

The ten-year insenice inspection required by NRC Regulatory Guide 1.147 was completed on the Reactor Coolant Pump 'C' motor flp heci during the motor refurbishment in Cheswick, Pennsylvania.

The ten-year inspection consisted of a magnetic particle examination of 100*'o of the flyw heci surface area and ultrasonic examination of 100% of the flynheel volume. These examinations werc performed by Nuclear Energy Senices (NES) in accordance with Wolf Crcck nondestructive examination procedures. Union Electric Nuclear Engineering (UENE) and the Callanay site Authori7cd Nuclear Insenice Inspector (ANil) performed an in-depth review of the examination data, equipment certifications, personnel certifications, consumable material certifications, and procedures used to perform the flywheel examinations. No rejectable indications ncre detected by NES.

PageIof6 1

. -~ -

P r

Refuel 6ISI Summary Final Results' February 11,1994 Reactor Coolant Pump 'A' main pump case bolts were examined by the ultrasonic method via the f

bolt heater hole. All 24 bolts were successfully examined with no rejectable indications detected.

PRESSURIZER:

Pressuriier surge noule-to-bottom head ueld and surge noule inner radius surface areas uere examined by the ultrasonic method. In addition, the lower surface area of the support skirt wcld were examined by the magnetic particle method. No rejectable indications were detceted.

STEAM GENERATOR D:

Steam Generator 'D' primary inlet nouje inner radius surface area, primary outlet noule inner.

radius surface area, and the bottom head-to-tube sheet wcld were examined by the ultrasonic method.

In addition, all 24 support pad bolts were examined by the ultrasonic method. No rejectable indications wcrc detected.

RESIDUAL llEAT REMOVAL:

The Residual Heat Removal (RIIR) train 'A' and RHR to Safety Injection piping were examined by ultrasonic and liquid penetrant methods. A total of I ultrasonic and 23 liquid penetrant examinations were performed. No rejectable indications were detected.

CONTAINMENT SPRAY:

Containment Spray train 'B' pump discharge piping was examiacd by ultrasonic and liquid penetrant methods. A total of 5 ultrasonic and 5 liquid penetrant examinations were performed. No rejectable indications were detected.

ACCUMULATOR SAFETY INJECTION, HIGH PRESSURE COOLANT INJECTION, AND CHEMICAL VOLUME AND CONTROL:

Accumulator Safety Injection (ASI) loop 3 piping, High Pressure Coolant Injection (HPCI) pump discharge to Reactor Coolant System (RCS) piping, and Chemical and Volume Control System (CVCS) normal letdown piping were examined using ultrasonic and liquid penetrant methods A total of 3 ultrasonic and 2 liquid penetrant examinations were performed on these systems. No rejectable.

indications were detected.

MAIN STEAM, MAIN FEEDWATER, AND STEAM GENERATOR BLOWDOWN:

4 Main Steam loops I and 3 piping. Main Feedwater loops 1 and 4 piping (not including presenice inspection of the new stainless steel venturi welds) Auxiliary Feedwater Turbine pump steam supply:

piping, and Steam Generator 'B' blowdown piping were examined by ultrasonic, liquid penetrant, and magnetic particle methods. A total of 23 ultrasonic,2 liquid penetrant, and 3 magnetic particle -

cxaminations were performed on these systems. No rejectable indications were detected.

Thermal fatigue cracking has been recently discovered at Diablo Canyon Unit I and at Sequoyah -

Units I and 2 in feedwater to stearn generator pipe welds. These insenice failures were identified in :

NRC Information Notice 93-20,.* Thermal Fatigue Cracking of Feedwater Piping to Steam Generators,"

dated March 24,1993. In response to these recent insenice failures, the Steam Generator 'B' feedwater noulc-to-pipe wcld was examined by the ultrasonic method during Refuel 6. This was an out-of-scope.

examination not identified'in the Callaway ISI Program Plan. No esidence of thermal fatigue cracking or any other sen ice related indication was detected.

l Page 2 of 6 i

I Refuel 6 IS! Summary final Results l'cbnmry 11,1994 "i

FEEDWATER VENTURI MODIFICATION (CMP 92-1033) PRESERVICE INSPECTIONS (PSI):

)

New stainicss steel feedwater venturis were installed in the Main Feedwater system during Refuel

6. The 1989 Edition of ASME Section XI requires all Class 2 dissimilar metal wcids be examined by both volumetric (ultrasonic) and surface (magnetic particic or liquid penetrant) examination methods.

The current iS1 Program Plan requires only an ultrasonic examination per the rules of NUREG 0800.

The second ten-year ISI program plan rules will be based on the 1989 Edition of ASME Section XI. In anticipation of these new 1989 Code rules, a baseline (PSI) ultrasonic examination and a liquid penetrant examina ion were performed on the 8 new venturi-to feedwater pipe dissimilar metal utids.

r In addition, a baseline ultrasonic examination was performed on the 8 hand hole-to-venturi welds as currently required b) NUREG 0800. No rejectable indications uetc detected.

CONTAINMENT COOLER PIPING MODIFICATION (CMP 91-1004) PRESERVICE INSPECTIONS (PSI):

Containment Cooler return and supply containment isolation vahcs were replaced with new style valves during Refuel 6 to mitigate seat leakage and to better ensure containment integrity. A total of 20 Class 2 welds were made to install these new valves. The 1989 Edition of ASME Section XI requires -

t that 7.5% of the total population of Class 2 wcids (i.e., newly installed plus original construction welds) l in containment heat removal systems be examined by both volumetric (ultrasonic) and surface (magnetic particle or liquid penetrant) examination methods. Containment Cooler reture md supply lines are currently excrnpted by Callaway's first ten-year ISI Program Plan. The second ten-year ISI.

Program Phm rules will be based on the 1989 Edition of ASME Section XI. In anticipation of these new 1989 rulet, a baseline (PSI) ultrasonic examination and a magnetic particle examination were performed on 9 of the new Containment Cooler Train 'A' and Train 'B' supply or return line pipe welds.

The PSI on thesc 9 welds satisfies the 7.5% cxamination population for the second ten-year interval.

+

No rejectable indications were detected.

4 VISUAL EXAMINATIONS ON PIPING, COMPONENTS, AND SUPPORTS SYSTEM LEAKAGE INSERVICE, AND FUNCTIONAL PRESSURE TESTS:

A system leakage pressure test was completed on 100% of all Class I piping and components during Refuel 6. The visual examination for leakage (VT 2) was performed with the system (s) at i

normal operating temperature and pressure. No pressure boundary leakage was identified.

Approximately 98% of the required Period 3 (e.g., third forty-momh period in the first ten-year interval) system insenice or functional pressure tests on Class 2 and 3 piping and components were complete at the conclusion of Refuel 6. No rejectable pressure boundary leakage was identified as a result of the visual examinations for leakage during these pressure tests. Minor "non-pressure boundary" leakage w as documented, and subsequently either evaluated to be acceptable or corrected.

TEN YEAR ISI IlYDROSTATIC PRESSURE TESTS:

A pneumatic pressure test was completed on the 'B' Diesci Generator Starting Air System during Refuel 6 No rejectable pressure boundary leakage was identified during this pneumatic test. Minor "non-pressure boundary" leakage at threaded connections was documented. and subsequently either crahiated to be acceptable or corrected.

Callaway intends to imoke the new rules as approved by the NRC in Code Case N-498 (reference Regulatory Guide 1.147, Resision 10). These new rules allow a VT-2 examination for leakage during an insenice or functional test in lieu of the ten-> car ISI hy drostatic test for ASME Class I and 2 Page 3 of 6

7

..A Refue' 6 ISI Summary Final Results l

February 11,1994

.l j

systems. Based on this, no ten-year ISI hydrostatic tests were performed on Class I or 2 systems during Refuel 6.

i Listed below are the Class 3 systems requiring a hydrostatic pressure test by the end of Callaway's first ten-year interval. Also listed is the system identification and the percentage complete.

PERCENTAGE SYSTEM DESCRIPTION SYSTEM ID COMPLETE

~

F.aci Pool Cooling and Cic:mup EC 100 %

.]

Essential Scnice Water EF 100 % -

Component Cooling Water EG 95 %

I Atniliary Feedwater Turbine FC 100 %

Misc, Building ilVAC GF 1(XPK o

Fuelllandling Building IIVAC GG 100 %

l Control Duilding HVAC GK 10(r%

j Atnitiary Building liVAC GL 100 %

Conta:nment Cooling G r=

100% ~

i Compiessed Air KA 100 %

Standby Diesel Engine KJ 35 %

Floor and Equipment Dmins LF 100 %

i i

Approximately 13 hydrostatic pressure tests remain to be completed on ASME Class 3 systems.

i The Component Cooling Water (CCW) side of the 'A' RHR licat Exchanger, CCW side of the Letdown Heat Exchanger, and CCW side ofi-Scal Water ficat Exchanger hase not yet been hydrostatically tested. In addition, the fuel oil,jacn water cooling, and lube oil auxiliary systems for Diesci Generator 'A' and 'B' remain to 'ic i.,drostatically tested. Callaway intends to invoke the alternative i

rules delineated in the pending Code Case N-498-1. This Code Case would allow an inscrnx leak test in lieu of the hydrostatic pressure test for ASME Class 3 systems.

PIPE SUPPORTS AND COMPONENT SUPPORTS:

The selection of piping and component supports for visual examination (VT-3 and/or VT-4)is in accordance with the Statistical Sampling Plan delineated in the Callaway ISI Program Plan. Listed below is a breakdoun of 62 supports scheduled for visual ex:miination in the third forty-month period and completed during Refuel 6. No rejectable conditions were identific(L NUMBER OF SYSTEM DESCRIPTION SYSTEM ID EXAMS 1

Main Fecdweter AE 5

Auxiliary FerAwater

'AL 2

Reactor Cor>lant BB 2

Chemicaland Volume Control BG 9

.l Rea: tor Makeup Water BL 1

i

. Steam Generator Blowdown BM 2

Essential Scnice Water EF 6

Component Cooling Water EG 16 Residuallicat Removnl EJ 4

liigh Pressure Coolant injection EM 4

f Containment Spray EN 1

Accumulator Safety injection EP 2

Auxiliary Feedwater Turbine FC 1

~

Contaimnent Cooling GN 4

l l

Page 4 of 6

Refuel 6 ISI Summary Final Results February 11,1991 j

r

'i Emergency Fuel Oil JE 1

j Standby Diesel Generator KJ 2

.l In addition to the sisual examinations listed above, a total of 12 supports on the Accumulator i

Safety injection system and I support on the High Pressure Coolant Injection system were sisually examined during Refuel 6 due to previous unsatisfactory conditions discovered during Refuel 4. All supports were found to be satisfactory with one exception. A strut assembly pipe clamp stud was found

.j loose on a support for the Accumulator Safety Injection system. The supports immediately upstream and downstream were visually examined and foun;i to be satisfactory. The loose stud was evaluated in -

accordance with the Callaway ISI Program Plan and categorized as an " unexplained failure" since there.

is no record of a transient event (e.g., water hammer) and because the location of the subject support is such that other work activitics in the area would not have caused the loose stud. Based on this and on i

the Callaway ISI Program Plan, this support will be visually examined again during the next forty.

month inspection period.

EQUIPMENT SUPPORTS:

A total of 8 v sual examinath.s (VT-3's) were performed on equipment supports during Refuel 6. Listed in the table below are the equipment supports visually examined, a brief description of the support, and the number of examinations on each support. No rejectable conditions were found.

'l 1

SUPPORT NUMBER OF -

t EQUIPMENT DESCRifrTION EXAMS'

{

Diesel Generator 'A' Lube Oil Cooler Fore and all support saddics 2

1 Diesci Generator 'A' Main Lube Pedestal supports 2.

Duplex Oil Strainers Component Cooling Water Pump 'A' Pedestal support 1

Residual Heat Removal Pump 'A' Lateral strut supponis 2

i Boron injection TanlJ 1-beam support leg at 300* mark 1

I llPGRAL ATTACHMENTS:

1 q

. total of 16 visual examinations (VT-3's) were performed on pressure boimdaiy integral attachments during Rcruel 6. The integral attachments for the system and/or equipment visually.

i examined are listed below. No rejectable conditions were identified.

d

- NUMBER OF

)

FQUIPMENT/ SYSTEM DESCRIPTION -

EXAMS Auxiliary Feedwater Pipe lugs 3

Diesel Generator 'A' Lube Oil Fore and all suppor; saddleintegral 2

l Cooler attachments Diesel Generator 'A' Main Lube Pedestal support integral attachments 2

)

Duplex Oil Straincts l]

Component Cooling Water Pipe lugs 7

1 Essential Service Water

~ Pipe lugs 2

VALVE BODY INTERNAL SURFACES AND BOLTING:

l The internal surface area of the Pressurizer 'B' safety relief vah e was visually examined (VT-3) during Refuel 6. No internal degradation, corrosion, or indication of failure was detected. In addition, a sisual cumination (VT-1) was completed on 10 valve or flange bolted connections in the

)

Page 5 of 6 j

a l

i

.]

j Refuel 6 ISI Sununary Final Results 1

Felwary 11,1994 j

Accumulator Safety injecti'm, liigh Pressure Coohnt injection, Chemical and Volume Control, Residual llcat Removal, or Reactor Coolant System. No rejectable conditions were identified.

t STEAM GENERATOR EDDY CilRRENT EXAMINATIONS 5

Steam generator cddy current examinations were performed in accordance with Callaway Technical Specification 4.4.5. One hundred percent of the unplugged tubes in Steam Generators 'A' and 'D' werc examined full length using a standard bobbin coil probe. A total of 482 tubes in 5tcam Generator 'A' and

'i 126 tubes in Steam Generator TY were examined with the rotating pancake coil (RPC) in the hot leg cxpansion region for signs of Primary Water Stress Corrosion Cracking (PWSCC). Additional RPC l

cxaminations ucre performed on 31 Steam Generator 'D' tubes and 37 Steam Generator 'A' tubes to further disposition b;>bbin coil indications, The primary damage mechanism identified by cddy current examinations was Anti-Vibration Bar

( AVII) wear. No evidence of PV SCC was deiccted. A total of 199 tubes with avl 3 indications were fi of u hich 104 had at least one intiication greater than or equal to 20% throughwall.

[

i The rotating pancalc coil dna for 3 tubes in Steam Generator 'A'showed signals as high as 70%

[

throughuall. Subsequent low h xluency bobbin coil examinations on these tubes showed a foreign object lodged outside the tubes. In order to detennine the extent of damage,64 additional tubes in this region

(

were examined with a rotating pancake coil. A total of 5 tubes were plugged due to possible wall thinning.

i from foreign objects lodged outside the tubes. A Foreign Object Scarch and Retrieval (FOSAR) was performed to locate and remove the foreign object. The foreign object was later determined to be wcld slag.

A. total of 19 tubes in Steam Generator 'A' and I8 tubes in Steam Generator 'D' were plugged. Seven of the tubes plugged had indications greater than the Technical Specification limit of 48% throughwall. The remaining 30 tubes were plugged since they were considered a risk to continued operation over the next 3 years.

F

+

REPAIRS, REPI.ACEMENTS. AND MODIFICATIONS Approximately 421 ASME Section XI repairs, repbccments, or modifications were completed on ASME Class 1, 2, or 3 components, parts, and appurtenances during the time period beginning with Refuel

$ bneter closure (May 18,1992) and ending with Refuel 6 breaker closure (November 22,1993).

Every repair, replacement, or modification completed in accordance with ASME Code requirements at

[

Callaway has been reported on Callaway's Form N15-2 Report, to document the extent of work performed and to provide traceability of new parts and/or. A ' 1s. The Form NIS-2 is not required by the governing code, however, this method of reporting is employed to ensure code con.pliance.

5 f

CONCI tiSION Approximately 158 nondestructive examinations. 97 visual examinations, and 102 pressure tests werc.

completed on ASME Class 1,2, and 3 components or wclds during Refuct 6 (this total does not include

.[

cddy current examinations on steam genc~ator tubes). As a result of these ASME Section XI examinations and tests performed and of the conditions observed, there is no general safety concern for the pressure retaining integrity of the safety-related systems at the Callaway Nuclear Plant.

i t

h Page 6 of 6 1

i

'?

., _