Proposed Tech Specs Re Addl Containment Isolation Valve Being Installed as Part of Sys for Maintaining Constant Differential Pressure Between Torus & Drywell
ML20024G388
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 03/11/1976
From:
NORTHERN STATES POWER CO.
To:
Shared Package
ML20024G381 List:
References
NUDOCS 9102110410
Download: ML20024G388 (4)


Text

.

l 1T4 U"

20 U

TAPLE.5.7.1

>w DO

]

04 PRIfMRY CCfCAIIC4EITT ISOLATION gg*

09 t3 W OO Isolation Valve Number of t

U83 Group Identification Valves Maximum M

Operating Normal

@g" Inboard Outboard Time (Sec)

Positicn 1

(J 4

1 Main Steam Line Isolation 4

4 3 I TI5 Open 1

Main Steam Line Drain 1

1 60 Closed 1

Recirculation Loop Sample Line 1

1 60 Closed 2

Drywell Floor Drain 2

60 Open 2

Drywell Equipment Drain 2

60 Open 2

Drywell Vent 2

60 Closed 2

Drywell Vent Bypass 1

60 Closed 2

Drywell Purge Inlet 2

60 Closed 2

Drywell and Suppression Chamber 1

60 Closed Air Makeup 2

Shutdown Cooling Gyutem 1

1 120 Closed l

2 Suppression Chamber Vent 2

60 Closed 2

Suppression Chanber Vent Bypass 1

6G Open 2

Suppression Chambe:r to Drywell 1

60 Open N2 Recirculation 153 REV 3 7/4.7

Table 3 7.1 Primary Containment Automatic Isolation Valves Permissible Isolation Group Isolation Valves Operating Nor-ml (Note 1)

Application Inboard Outboard Time (sec)

Pccition 1

Fain Steam Isolation AO-2-80A A0-2-86A 3 <t< 5 Open A0-2-80B A0-2-86B

~

AO-2-80C A0-2-86C AO-2-80D AO-2-86D l

Main Steam Line Drain MO-2373 MO-2374 t 160 Closed

(

Ecactor Water Sample CV-2790 CV-2791 t <60 Closed j

Dryvell F uipment Sump AU-2561A AO-2561B t 160 Open 2

4 Dryvell Floor Sump AO-2541A AO-2541B t <60 Open M

CV-238h t <60 Open g

Torus Vent Bypass Torus to Dryvell N2 Beelrc CV-74hO t$0 Open E

6 o

Torus Vent A0-2383 t $60 Closed y-f

'Ibrus Vent AO-2896 t <60 Closed Dryvell Vent Bypass CV-2385 t $60 Closed Dryvell Vent AO-2386 t $60 Closed y

Dryvell Vent AO-2387 t $60 Closed

'ibrus Air Purge Air Supply AO-2378 t 160 Closed p.

Dryvell Air Purge Supply AO-2381 t 160 Closed s-o containment Air Purge Supply A0-2377 t$60 Closed TIP Ball Valves ( 3)

Note 2 Closed N

Nitmgen Pumpbsch Suction CV-7h36 t <(20 Open t>

Nitrogen Pu=pback Suction CV-7h37 t <60 Open es 153 37/h.7 RE/

i f

~

r Tnble 4.7,1 Nnticello Cbntainment Penetrations (continued)

CUEER BARRIER APlicable Appendix INNER BARRIER P

J Type 'Ibst Designation Type ? Testable Designation 1YPc Destable Bemtration Desigration Description C

CRD-3h 5

No CRD-31 5

Yes X-36 CRD llydrnulic Return X-37A - 3?D CRD Insert Lines (121)

NWE (Note 5) 5 X-39A - 38D CRD liithdraw (121)

NWE (Note 5) 5 l

X-39A Drywell Spray B C

i MO-2021 h

Yes MO-2023 h

Yes X-39B Dryvell Spray A C

MO-2TO h

Yes MO-2022 4

Yes S

"m

<a X-40A-A-40D-F Instrumentation NWE (Note 3) 18 CV-2790 9

Yes CV-2791 9

Yes X lol Pecire loop B Sample C

XP-7 5

No XP 6 5

Yes

<+

X-42 Standby Liquid Contro]

C 17 M

X-43 47 Spare Penetmtions NONE

~

y CJ-7436 9

Ye8 2

X-k8 Nitrogen Pumpbnck C

Suction Cv-7437 9

Ye8 y

a X-b9A 49F Instru:uentation NNE (Note 3)

~

~

~

18 X-50A - SOD Instnamentation NONE (h_ote 3) 19 U

E X-50E - SOF Instrumentation NONE (Note 8) 18 q

X-51A - 51F Instrumentation NWE (Note 3) 18

[5 X-52A - 52F Instrumcatation NWE (Note 3) w X X-99 mt Assigned NWE o

'oI i

154H 37/h.7 asy

i e

a

[

hble h.7.1 Bbnticello containment Penetrations (continued)

Penetration Applicable Appendix INNER BAIGIFR OEffER BARRI?R Designation Description J Type Test Designation Type Testable Designation Iypee Testable 4

1 i

X-202I Not Assigned NONE i

X-203 Not Assigned-NWE 1

t i:

Torus' Ring Header NONE (Note 7)

X-204A - 204D X-205 Torus Ventilation C

s AO-2383 10 Yt s

{

l-Exhaust CV-2384 9

Yeu I

t AO-2896 10 Yes 9

CV-7440 9

Yes l L#

i o

G t

s l

X-206A - 206D Torus Instrumentation NONE (Note 8) 19

  • e

{

N l

X-207A - 207H Torus Vent Pipe Drains NONE (Note 7) l l

j X-208A - 208H Relier Valve Discharge NONE (Note 7)

Pipes 1

5 X-20)A - 209D Torus. Instrumentation NOIE (Note 8) 19 2

l 0

j X-210A RHR and Core Spray B -

N M E (Note 9)

RHR-8-2 5

e

}

Test Line to '1brus l

y MO-2OO7 4

g

[

i I-n MO-2009 12 tm i

MO-1750 12 I

f 4

I I

CS-10-2 13 se a

o r

=

i Y

i D

4 1

L 4

i e

f 3 7/4.7

^me 15kJ i

REV l

i

...,..